Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : January 2009
Security Incident Explosives Type Quantity Description Loss of explosives Blasting 1 x 150 gram
Booster During a stocktake at a magazine it was found that one of the boxes containing boosters was deficient by one 150g booster. The box had not been opened since manufacturer packaging. A similar set of circumstances occurred at another location
Theft of explosives None reported during January 2009 Spillage Blasting Bulk Ammonium
Nitrate < 1200 kg A bulka bag was not secured appropriately which resulted in it falling over and spilling AN onto the road. The bag and seal failed due to being defective or being roughly handled
Safety Injury or property damage
High Potential
Explosive Type
Industry Sector Description
Misfire Yes Blasting Shotfirer While digging out a shot overburden, a downline cord with an attached booster and detonator became caught in the bucket of the excavator. A contributing factor was the failure of the explosives down line.
Misfires No Blasting Shotfirer There were 21 misfire incidents reported for the month of January
Chief Inspector of Explosives
Our Vision : Our community safe and secure from explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : February 2009
Security Incident Explosives Type Quantity Description Loss of explosives None reported for February 2009 Theft of explosives None reported for February 2009
Safety Nature of Harm High
Potential Explosive Type Industry
Sector Description
Potential for death, serious injury, or property damage
Yes Blasting Shotfirer A digger operator found unexploded product, and upon investigation found a live lead. Shotfirer retied the shot and fired it successfully.
Potential for poisoning
No Blasting Shotfirer Observation of oxides of nitrogen during blasting at mine
Potential loss of explosives product
No Blasting Shotfirer Rain event caused Ramp to flood overnight. Primed and loaded blast holes went underwater
Potential for death, serious injury, or property damage
No Blasting Shotfirer 12 Misfires reported for February 2009 Hole dislocation 2, Product failure 2, Shotfirer error 1, Slumping 1, Unknown 6
Spillage of ammonium nitrate
No Ammonium Nitrate prill
Shotfirer Whilst loading a tipper, a bag of Ammonium nitrate prill was raised over the hopper and cut to release the contents. The AN had formed into hardened blocks. A block of approximately 200 kg fell to the ground.
Chief Inspector of Explosives
Our Vision : Our community safe and secure from explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : March 2009
Security
Incident Explosives Type Quantity Description Loss of explosives None reported for March Theft of explosives None reported for March Other None reported for March
Safety
Nature of Harm
High Potential
Explosive Type Industry Sector Description
None No Blasting Shotfirer 21 misfires reported for the month of March : 5 shotfirer error, 4 product failure, 1 flyrock, 1 slumping, 1 geological fault, 9 unknown One misfire was considered a high potential incident where a Full length misfire was found in the back of a development heading by the shot creating crew. A Jumbo had drilled within 150mm of misfire. The misfire was not identified by either the face prep crew or the Jumbo operator
Chief Inspector of Explosives
Our Vision : Our community safe and secure from explosives
Our Vision : Our community safe and secure from explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : April 2009
Security
Incident Explosives Type Quantity Description
Blasting Residual of spill
The driver of a B-double laden with thirty 1.2 tonne bulka bags of SSAN pulled over to the verge to allow a wide-load vehicle under police escort to pass. A steep shoulder leading to the road dish drain caused the vehicle combination to slide from the road way and fall onto its side. Two bags of SSAN split and product spilled onto the grass verge. Minor diesel fuel leaks occurred from the fuel tanks of the prime mover. The leaks were contained using the onboard spill kit and did not contaminate any SSAN. The driver was uninjured.
Theft of explosives None reported for the month. Other A safe containing explosives magazine keys was stolen from a mine site.
Safety
Nature of Harm High Potential
Explosive Type
Industry Sector Description
None No Blasting Shotfirer Twelve misfires were recorded for the month: 5 product failures, 1 shotfirer error, 1 column dislocation and 5 unknown.
Page 2 of 2
Nature of Harm High Potential
Explosive Type
Industry Sector Description
None Yes Blasting Shotfirer
A production rig was drilling blastholes approximately 15 metres from a charged shot. When the operator blew out the hole, explosives in one blasthole located in the charged shot area were forced out of the blasthole by air pressure from the drill rig. It would appear that the air pressure has travelled from one hole to another via fissures in the rock.
None No Blasting Shotfirer A shotfirer was in the process of programming a new type of remote firing equipment for electronic detonators, prior to firing shot, when two blastholes detonated prematurely.
None No Blasting Shotfirer Whilst investigating a misfire it was established that at crib break time the entire blast crew broke for crib and left the partially loaded shot unguarded
None Yes Blasting Shotfirer
MMU was on bench loading a baited shot. It was driven across unloaded but baited shot knocking over staked downlines. The MMU operator backed up to check damage and ran over downlines again. Operator alighted from MMU, put stake back into drillings and drove off. Shotfirer observed the operator’s actions, checked downlines and found one cut and one damaged.
None Yes Blasting Transport An EP pump trailer fire caught fire when its disc brakes locked. Personal injury Yes Blasting Transport A B-double truck rolled over while loaded with 40 tonnes of emulsion
None Yes Blasting Shotfirer A dozer entered onto an active bench. A shot was being loaded when a dozer driver traversing the area entered through the reload access. It was stopped by shot crew before it reached loaded or baited holes.
Loss of explosives Yes Blasting 200 Litres emulsion
Two rail cars carrying ammonium nitrate emulsion were derailed. Approximately 200 litres of emulsion was split onto the ground
Chief Inspector of Explosives
Our Vision : Our community safe and secure from explosives
Chief Inspector of Explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : May 2009
Security
Incident Explosives Type Quantity Description
Loss of explosives Boosters 40 only PDP boosters lost from back of shotfirer’s utility Theft of explosives None reported for May Other Blasting Unknown Magazine keys left in shotfirer’s utility overnight Other Blasting Unknown Electricity failure on main feed at Government Explosives Reserve
Safety
Nature of Harm High Potential
Explosive Type Industry Sector Description
None No Blasting Shotfirer 16 reports of Misfires for May 1 Column Dislocation, 2 Detonator Failure, 3 Loading Method, 1 Slumping, 1 Rockfall, 1 Initiation System Failure, 2 Shotfirer Error, 2 Product Failure, 3 Under Investigation
None Yes Blasting Shotfirer One misfire considered to be a High Potential Incident, where a jumbo operator drilled within 150mm of a previous misfire
None Yes SSAN Transport Trailer tipped over at reload area None No SSAN Transport Loss of containment, SSAN spill from truck
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : June 2009
Security Incident Explosives
Type Quantity Description Theft of explosives None reported. Loss of explosives None reported. Other Detonators 2 x 20' Containers Containers left on wharf for two weeks. Inspectorate not advised of import.
Safety Nature of Harm High
Potential Explosive Type Industry Sector Description
None No Blasting Shotfirer Fourteen misfires reported for June: 4 dislocations, 4 procedures, 3 initiation system failures, 1 product failure, 1 wet hole, 1 slumping.
Property damage Yes Blasting Shotfirer A blast at a quarry generated flyrock which travelled approximately 300m. No injuries, $5,000 property damage.
None Yes Blasting Transport An MPU failed to negotiate a corner and rolled over. The lid of the MPU failed, allowing emulsion to spill.
None Yes Blasting Shotfirer Nitrous Oxides created by a blast. Blast fume concern from drillers who were 3.8km from the blast. No injuries and the Blast Controller at the 1.0km exclusion zone felt that the blast fume was not a hazard to site or personnel.
None Yes Blasting Shotfirer Grey smoke seen coming from a loaded hole at a mine. None No SSAN Transport Loss of SSAN in transit due to two damaged bulka bags.
The security seals were intact on the damaged bags. Injury No SSAN
Emulsion 2.5 tonnes 20 litres
While travelling from the depot to a site, an MPU failed to negotiate a corner and rolled over.
Chief Inspector of Explosives Our Vision : Our community safe and secure from explosives
Chief Inspector of Explosives
Our Vision : Our community safe and secure from explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : July 2009
Security Incident Explosives Type Quantity Description Loss of explosives None reported for the month of July Theft of explosives None reported for the month of July Other None reported for the month of July
Safety
Nature of Harm High Potential Explosive Type Industry
Sector Description
None Yes Blasting Shotfirer Eighteen misfires reported for the month of July : 2 stemming, 1 slumping, 1 shotfirer error, 1 desensitisation, 2 column dislocations, 1 product failure, 2 initiation system failures, and 8 unknown
Personal illness Yes Blasting Shotfirer A Nitrous Oxide blast fume affected fourteen persons with nausea and headaches. These persons were 650 metres from the blast, which had an exclusion zone of 500 metres. A sudden change in wind direction was a contributing factor. Later on it was realised that these persons had varying levels of exposure and subsequently some of them attended hospital for observation.
None Yes Blasting Shotfirer A post-blast fume event at a coal mine resulted in a visible fume, which lasted approximately 10 minutes
None Yes Blasting Storage A corner of an ANFO unit load caught on a wooden pallet tearing a small hole in a bag of ANFO.
None Yes Blasting Shotfirer A post blast fume event occurred at a coal mine.
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : August 2009
SecurityIncident Explosives Type Quantity Description Theft of explosives None reported for the month
Loss of explosives Rail Signals 1 railway track signal Rail track signal unaccounted for. An employee had lost the device from his pocket while performing some duties. Signal later located.
Other Blasting Explosives left unsecured at Copper Mine.
SafetyNature of Harm
High Potential
Explosive Type Industry Sector Description
None No Blasting Shotfirer 48 Misfires : 42 Unknown, 1 Slumping, 3 Product Failure, 2 Dislocation. None Yes Blasting Shotfirer Post blast fume generated appeared excessive. None Yes Blasting Shotfirer Post blast fume generated appeared excessive. Vehicle damaged
Yes SSAN Transport SSAN truck fire caused by brakes over-heating.
None Yes Blasting Shotfirer Nitrous Oxide Fume generation from a fired shot. Post blast fume generated appeared excessive.
Damaged machinery
Yes Emulsion Shotfirer Emergency declared after operator noticed noise and possibly smoke from Napco transfer pump. Operator was transferring emulsion when a strange noise was noticed. Operators then thought they saw smoke and shut down pump. Called an emergency and evacuated pit. Declared safe within 3 hours. Root cause identified as an over tightened set screw which in turn caused a bearing to collapse.
Our Vision : Our community safe and secure from explosives
Nature of Harm
High Potential
Explosive Type Industry Sector Description
None No SSAN Transport SSAN spill on Highway. Container discharge chute lock has broken and product has spilled out for several kilometres along the Highway.
None Yes SSAN Manufacture Grass fire - ANFO plant. It is believed an electrical short outside an ANFO manufacturing building started a small grass fire which burnt an area outside the plant.
Breach of exclusion zone
Yes Blasting Shotfirer Blast Site Exclusion Zone Violation - Pump crew drove light vehicle onto loaded shot during Night Shift. Barricading and signage was in place, the signage had fallen over prior to the pump crew accessing the area. The pump crew drove onto the pattern and into the area of loaded holes.
Breach of exclusion zone
Yes Blasting Shotfirer Blast guard who was also shot firer left ramp to check blast. Fitter drove into area.
Chief Inspector of Explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : September 2009
Security Incident Explosives
Type Quantity Description
Loss of explosives None reported for September 2009 Theft of explosives None reported for September 2009 Other None reported for September 2009
Safety Nature of Harm High
Potential Explosive Type
Industry Sector
Description
None Yes Blasting Shotfirer 18 misfires reported for month – 1 blast design, 1 product failure, 1 dislocation, 2 initiation errors, 1 shotfirer error, 1 slumping, 2 stemming, and 9 unknown
None Yes Blasting Shotfirer A Jumbo operator drilled in close proximity to misfire
Property damage Yes Blasting Transport Brake fire on a Triple B transporting a triple load of AN prill None Yes Blasting Shotfirer An MPU has impacted and cut a downline. None Yes Blasting Shotfirer An excavator was cleaning up a highwall post blast and located unfired ANFO, downline
and booster. Attributed to column dislocation caused by poor blast design and timing None Blasting Manufacture
- vehicle While conducting maintenance on a cabover MMU, a contract fitter over jacked the cabin, which then fell forward onto the ground.
None Yes Blasting Transport A vehicle arrived at a Government Explosives Reserve with a pallet of detonating cord that had fallen over in the carry box during transport.
Personal injury Yes Blasting Shotfirer Post blast fume events were reported at four separate sites during the month. One person received medical treatment.
Chief Inspector of Explosives Our Vision : Our community safe and secure from explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : October 2009
SecurityIncident Explosives
Type Quantity Description
Loss of explosives Blasting 1 x PPP400 booster
A shotfirer and magazine keeper recognised a discrepancy in the count of boosters. It appeared that one had been left on the shot.
Theft of explosives None reported for October Other Blasting Not applicable Persons unknown broke in to a compound and syphoned 400 litres Diesel. Stocktake
confirmed no Emulsion or SSAN was stolen
SafetyNature of Harm High
Potential Explosive Type
Industry Sector
Description
None Yes Blasting Shotfirer 35 misfires reported for the month : 11 initiation system failures, 2 slumping, 1 dislocation, 5 procedures, 3 blasting method, 13 unknown
None Yes Blasting Manufacture Due to bearing failure, a mixing paddle stopped on an explosive precursor chemical tank. An attempt by personnel to agitate and cool contents using a sparge has intiated a reaction, producing cloud of blue grey fume. QFRS, QPS and Hazmat attended
None Yes Blasting Shotfirer 3 Post blast fume events, one a High Potential Incident of rating 3 Property damage Yes Fireworks Fireworks An unauthorised person lit an aerial firework, which then fell in a neighbouring yard
and continued to fire. Property damage and a series of small grass fires resulted, which were extinguished by other party goers. Complaints were made by neighbours.
None Yes blasting Store While cutting regrowth in a magazine compound a piece of uni-flex cord was uncovered
Chief Inspector of Explosives
Our Vision : Our community safe and secure from explosives
Significant explosives accidents and incidents Safety and Health
Explosives Inspectorate For : November 2009
Security
Incident Explosives Type
Quantity Description
Loss of explosives None reported for November Theft of explosives Blasting Starter gun and
10 to 15 primers Alleged theft of a starter gun and 10 to15 primers, stolen from a shotfirer vehicle whilst parked at place of residence.
SafetyNature of
Harm High
Potential Explosive
Type Industry Sector Description
None No Blasting Shotfirer 39 misfires reported, one a high potential incident – 8 initiation system failure, 5 procedure, 4 blasting method, 2 slumping, 1 dislocation, 19 unknown.
None Yes Blasting Shotfirer A shot firer alighted from a vehicle without applying the handbrake and the vehicle has rolled 20 metres, coming to a stop after colliding with a pump.
Personal injury
Yes Blasting Shotfirer Shot fired and small amount of fume generated - 0 on scale of 0-5. A high wind above the pit at time has transported dust from shot towards the CHPP. A maintenance worker was outside the CHPP at the time, and complained of irritation to eyes and nose. In line with MS procedures the worker was taken to town for medical assessment. OMS provided technical support to medical staff on symptoms and effects of post blast gases.
None Yes Blasting Shotfirer A small highwall slip occurred while the blast crew were loading the shot. No injuries were reported nor have any explosive accessories been struck.
None Yes Blasting Manufacture - Vehicle
Fire on an MPU unit – the fire started below the engine bay area when oil on the exhaust pipe ignited. The fire was extinguished with a hand held extinguisher and the fire suppression system on the MPU.
Chief Inspector of Explosives
Our Vision : Our community safe and secure from explosives
Significant explosives accidents and incidents
Explosives Inspectorate For : December 2009
Security
Incident Explosives Type
Quantity Description
Loss of explosives A 15m 600ms downhole detonator lead was lost down a blast hole while the leads were being thrown out.
Theft of explosives None reported for the month Other Blasting 50 kg Fifty kilograms of explosives had been picked up by a loader underground and put into a
dump truck, which then dumped the explosives on the ROM. It is thought that the explosives had misfired in a stope and had been picked up by the loader.
Blasting 200 kg An operator overflowed an Emulsion Phase tank at a manufacturing plant. Approximately 200 kilograms was spilt, but was contained in a bund.
Blasting
Small amount
A 30 tonne forklift was being used to pick up a prill container when a fork punctured a side wall of the container. A small amount of prill was spilled.
Blasting 25 tonnes A triple-B load (63 tonne) of class 5.1 SSAN prill was being transported from the manufacturing plant to a mine site, when the rear trailer stepped off the left hand verge and rolled onto its side, pulling centre trailer over as well. The Ringfeder connecting the dolly to trailer A twisted, resulting in the prime mover and trailer A remaining upright. 25 tonnes of prill was spilt through a broken feed-out door on trailer B and its failed top load covers. Contaminated prill was quarantined and later disposed of. There were no injuries.
Our Vision : Our community safe and secure from explosives
Page 2 of 2
Safety
Nature of Harm High Potential
Explosive Type
Industry Sector
Description
None No Blasting Shotfirer Thirty-four misfires reported – 4 initiation system failures, 3 column dislocations, 1 bulk product failure, 1 loading method, 1 slumping, 1 procedure error, 23 unknown
None Yes Blasting Transport Whilst travelling down a decline on a haul road, a shot utility slipped sideways on a wet road surface. The utility slid onto a dry spot and flipped onto its side. The vehicle was carrying class 1 IE and HE. There were no injuries.
None Yes Blasting Shotfirer During an overnight inspection, an OCE discovered some baited holes that had been left unstemmed and unbagged by the contract shot crew.
None Yes Blasting Shotfirer A post-blast fume breached the 1 km exclusion zone. No exposures were reported. None Yes Blasting Shotfirer A coal mine received a complaint from a local resident, reporting an orange dust cloud
and a smell following a blast. The blast itself was rated low in terms of any fume (2 out of 5), but as the smell was reported it must be assumed that the fume passed over the boundary. Normal blasting procedures took place, however there was a large amount of dust due to the very large size of the blast, and very dry and windy conditions were prevalent at the time of the blast.
Personal injury Yes Fireworks Use An employee at a Government Explosives Reserve received a minor burn while stamping out a spot fire, caused by a firework escaping from a burn-off in a bunker.
Property damage Yes Blasting Use An asphalt container pad has cracks which allow water to penetrate the subsoil, thus making it weak. A side lifter loading an explosives container, loaded with 25 tonnes of explosives, had its support legs resting on the problem area. The legs penetrated the asphalt, which could in turn have tipped the lifter on it side along with its contents.
Chief Inspector of Explosives