Series description: Wilo-Stratos-D
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 1 / 30
9080604020 705030100 Q/m³/h0
2
6
8
10
12
14
16
4
H/m
80/1-12
65/1-16
50/1-16
65/1-12
40/1-16
32/1-8
32/1-12
40(50)1-8
Wilo-Stratos-D+
40/1-12
50/1-9
50/1-12
DesignGlandless double circulation pump with flange connection, EC motor withautomatic power adjustment
ApplicationHot-water heating systems of all kinds, air-conditioning systems, closedcooling circuits, industrial circulation systems
Type keyExample: Stratos‐D 40/1-8
StratosHigh-efficiency pump (flange-end pump),electronically controlled
D Double pump
40/ Nominal connection diameter
1-8 Nominal delivery head range [m]
Special features/product advantagesPosition-independent LC display•Infrared interface•System expansion by means of interface modules for communication:Modbus, BACnet, CAN, LON, PLR
•
Volume flow limitation by Q limit function (via IR stick)•Pump housing with cataphoretic (KTL) coating protects againstcorrosion due to condensation formation
•
Technical dataEnergy efficiency index (EEI) ≤ 0.27•Permissible temperature range ‐-10°C to +110°C•Mains connection 1~230 V, 50/60 Hz•Protection class IP X4D•Flange connection DN 32 to DN 80•Max. operating pressure, standard version: 6/10 bar or 6 bar (specialversion: 10 bar or 16 bar)
•
Equipment/functionOperating modes
Manual control mode (n=constant)•Δp-c for constant differential pressure•Δp-v for variable differential pressure•Δp-T for temperature-controlled differential pressure (programmablevia IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)
•
Q-Limit to restrict the maximum volume flow (setting only via IR-Stick)•Manual functions
Setting the operating mode•Setting the differential pressure setpoint•Setting automatic setback operation•Setting the pump ON/OFF•Setting the speed (manual control mode)•
Automatic functionsInfinitely variable power adjustment according to the operating mode•Automatic setback operation•Deblocking function•Soft start•Full motor protection with integrated trip electronics•
External control functions"Overriding Off" control input (possible with Stratos IF-Modules)•"Overriding Min" control input (possible with Stratos IF-Modules)•"Analogue In 0 ‐ 10 V" control input (remote speed adjustment)(possible with Stratos IF-Modules)
•
"Analogue In 0 ‐ 10 V" control input (remote setpoint adjustment)(possible with Stratos IF-Modules)
•
Signal and display functionsIndividual/collective fault signal (potential-free NC contact)(programmable with the IR-Stick/IR-Monitor)
•
Collective fault signal (potential-free NC contact)•Individual run signal (potential-free NO contact) (possible with StratosIF-Modules)
•
Fault signal light•LC display for indication of pump data and fault codes•
Data exchangeInfrared interface for wireless data exchange with IR-Stick/IR-Monitor•Modbus RTU serial digital interface for connection to buildingautomation BA via RS485 BUS system (possible with Stratos IF-Modules)
•
BACnet serial digital interface MS/TP slave for connection to buildingautomation BA via RS485 BUS system (possible with Stratos IF-Modules)
•
CAN serial digital interface for connection to building automation BAvia IF-Modules BUS system (possible with Stratos IF-Modules)
•
LON serial digital interface for connection to a LONWorks network(possible with Stratos IF-Modules)
•
PLR serial digital interface for connection to BA via Wilo interfaceconverter or company-specific coupling modules (possible with StratosIF-Modules)
•
Dual pump management (double pump or 2 x single pumps)Main/standby operation (automatic fault-actuated switchover/time-dependent pump cycling): various combinations with Stratos IF-Modules (accessories) possible
•
Parallel operation (efficiency-optimised peak load activation anddeactivation): various combinations with Stratos IF-Modules(accessories) possible
•
Features
Series description: Wilo-Stratos-D
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 2 / 30
Flange versions:•Standard version for DN 32 to DN 65 pumps: PN 6/10 combinationflange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16counter flanges,
•
Standard version for pumps DN 80: PN 6 flange (designed for PN 16according to EN 1092-2) for PN 6 counter flange
•
Special version for DN 32 to DN 80 pumps: PN 16 flange (accordingto EN 1092-2) for PN 16 counter flange,
•
Double switchover valve in pump housing•Plug-in position for optional extension with Wilo-IF‐Modules•
MaterialsPump housing: Grey cast iron•Shaft: stainless steel•Bearing: Carbon, metal impregnated•Impeller: Plastic•
Scope of deliveryPump•Incl. washers for flange screws (for nominal connection diameters DN32 ‐ DN 65)
•
Including installation and operating instructions•
OptionsSpecial versions for operating pressure PN 16•
AccessoriesCounter flanges for flange connection•Blind flanges•IR-Stick•IR Monitor•Stratos IF-Module: Modbus, BACnet, CAN, PLR, LON, DP, Ext. Off, Ext.Min., SBM, Ext. Off/SBM
•
Duty chart: Wilo-Stratos-D
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 3 / 30
Duty chart
Q/m³/h0 10 20 30 40 50 60 70 80 90 100
H/m
0
2
4
6
8
10
12
14
16
Wilo-Stratos-D+
50/1-12 65/1-12
80/1-12
40/1-12
40/1-16
65/1-16
50/1-16
40(50)/1-8
32/1-1232/1-8
50/1-9
Product list: Wilo-Stratos-D
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 4 / 30
Type Max. volumeflow
Max.delivery
head
Energyefficiencyindex (EEI)
Nominalflange
diameter
Ratedpressure
Overalllength
Mainsconnection
Grossweight
Art no.
Qmax / m3/h Hmax / m PN / bar l0 / mm m / kg
Stratos-D 32/1-8 13 7 ≤ 0.27 DN 32 6/10 2201~230 V,50/60 Hz
14.0 2090461
Stratos-D 32/1-12 21 10 ≤ 0.27 DN 32 6/10 2201~230 V,50/60 Hz
19.0 2090462
Stratos-D 40/1-8 26 8 ≤ 0.27 DN 40 6/10 2201~230 V,50/60 Hz
19.0 2090463
Stratos-D 40/1-12 35 12 ≤ 0.27 DN 40 6/10 2501~230 V,50/60 Hz
28.0 2090464
Stratos-D 40/1-16 36 17 ≤ 0.27 DN 40 6/10 2501~230 V,50/60 Hz
47.0 2150597
Stratos-D 50/1-8 26 8 ≤ 0.27 DN 50 6/10 2401~230 V,50/60 Hz
21.0 2090465
Stratos-D 50/1-9 38 9 ≤ 0.27 DN 50 6/10 2801~230 V,50/60 Hz
30.0 2090466
Stratos-D 50/1-12 41 12 ≤ 0.27 DN 50 6/10 2801~230 V,50/60 Hz
30.0 2090467
Stratos-D 50/1-16 57 18 ≤ 0.27 DN 50 6/10 3401~230 V,50/60 Hz
51.0 2150598
Stratos-D 65/1-12 69 11 ≤ 0.27 DN 65 6/10 3401~230 V,50/60 Hz
53.5 2150596
Stratos-D 65/1-16 79 17 ≤ 0.27 DN 65 6/10 3401~230 V,50/60 Hz
54.0 2150599
Stratos-D 80/1-12 109 13 ≤ 0.27 DN 80 6 3601~230 V,50/60 Hz
64.5 2150600
Stratos-D 80/1-12 109 13 ≤ 0.27 DN 80 10 3601~230 V,50/60 Hz
64.5 2150601
Data sheet: Wilo-Stratos-D 32/1-8
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 5 / 30
Pump curves Δp-c (constant)
0 2 4 6 8 10 12
0 1 2 3 4
14
14
0 1 2 3 4 5
0
1
2
3
4
5
6
7
0
10
20
30
40
50
60
70
0 2 4 6 8 10 120
100
200
300
min.
P1/W
max.
Wilo-Stratos-D 32/1-81~230 V - DN 32
p/kPa
m/sv
max.
∆p-c
+
P1 Wilo-Stratos 32/1-8
min.
1m
2m
3m4m5m6m7m
H/m
Q/m³/h
Q/l/s
Q/m³/h
Pump curves Δp-v (variable)
0 2 4 6 8 10 12
0 1 2 3 4
0 1 2 3 4 5
0
1
2
3
4
5
6
7
0
10
20
14
14
30
40
50
60
70
0 2 4 6 8 10 120
100
200
300
P1/W
Q/m³/h
Q/l/s
Q/m³/h
max.
Wilo-Stratos-D 32/1-81~230 V - DN 32
p/kPa
m/sv
+
P1 Wilo-Stratos 32/1-8min.
2m3m4m5m6m7m
min.
H/m
max.
∆p-v
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 32
Overall length l0 220 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 100.00 W
Speed n 1400 - 3700 rpm
Power consumption P1 9 - 130 W
Current consumption I 0.13 - 1.20 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPE - 30% GF)
Pump shaft Stainless steel (X30CR13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 32/1-8
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 6 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
182
10
61
12
107107
22
0
11
48
9
44
11
0
DN 32
Dimension drawing, flangeØ 140
Ø 100
Ø 90
Ø 76
DN 32
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Minimum suction head at 50 / 95 / 110°C
3 / 10 / 16 m
Information for order placements
Make Wilo
Type Stratos-D 32/1-8
Art no. 2090461
Weight approx. m 12 kg
Data sheet: Wilo-Stratos-D 32/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 7 / 30
Pump curves Δp-c (constant)
0 4 8 12 16 20
0 1 2 3 4 5 6
0 2 4 6
0
2
4
6
8
10
0
20
40
60
80
100
0 4 8 12 16 200
200
400
600
min.
H/m
P1/W
max.
Wilo-Stratos-D 32/1-121~230 V - DN 32
p/kPa
m/sv
max.
∆p-c
+
P1 Wilo-Stratos 32/1-12
min.
1m2m
3m
4m5m6m8m9m
7m
Q/m³/h
Q/l/s
Q/m³/h
Pump curves Δp-v (variable)
0 4 8 12 16 20
0 1 2 3 4 5 6
0 2 4 6
0
2
4
6
8
10
0
20
40
60
80
100
0 4 8 12 16 200
200
400
600
H/m
P1/W
Q/m³/h
Q/l/s
Q/m³/h
max.
Wilo-Stratos-D 32/1-121~230 V - DN 32
p/kPa
m/sv
+
min.
4m5m6m7m8m
min.
P1 Wilo-Stratos 32/1-12
max.
∆p-v
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 32
Overall length l0 220 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 200.00 W
Speed n 1400 - 4800 rpm
Power consumption P1 12 - 310 W
Current consumption I 0.22 - 1.37 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPS - 40% GF)
Pump shaft Stainless steel (X30CR13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 32/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 8 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
204
13
01
17
130110
22
0
12
01
06
57
11
0
DN 32
Dimension drawing, flangeØ 140
Ø 100
Ø 90
Ø 76
DN 32
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Minimum suction head at 50 / 95 / 110°C
3 / 10 / 16 m
Information for order placements
Make Wilo
Type Stratos-D 32/1-12
Art no. 2090462
Weight approx. m 16 kg
Data sheet: Wilo-Stratos-D 40/1-8
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 9 / 30
Pump curves Δp-c (constant)
0 5 10 15 20 25
0 2 4 6
0 1 2 3 4 5 6
0
2
4
6
8
0
20
40
60
80
0 5 10 15 20 250
200
400
600
H/m
P1/W
Wilo-Stratos-D 40/1-81~230 V - DN 40
p/kPa
m/sv
max.
∆p-c
+
P1 Wilo-Stratos 40/1-8
min.
Q/m³/h
Q/l/s
Q/m³/h
min.
max.
1m
2m
3m4m5m6m8m 7m
Pump curves Δp-v (variable)
0 5 10 15 20 25
0 2 4 6
0 1 2 3 4 5 6
0
2
4
6
8
0
20
40
60
80
0 5 10 15 20 250
200
400
600
H/m
P1/W
Q/m³/h
Q/l/s
Q/m³/h
Wilo-Stratos-D 40/1-81~230 V - DN 40
p/kPa
m/sv
+
min.P1 Wilo-Stratos 40/1-8
max.
∆p-v
max.
3m4m5m6m7m
min.
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 40
Overall length l0 220 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 200.00 W
Speed n 1400 - 4800 rpm
Power consumption P1 12 - 310 W
Current consumption I 0.22 - 1.37 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPS - 40% GF)
Pump shaft Stainless steel (X30CR13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 40/1-8
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 10 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
200
13
81
25
135115
22
0
12
01
06
64
11
0
DN 40
Dimension drawing, flangeØ 150Ø 110
Ø 100
Ø 84
DN 40
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Minimum suction head at 50 / 95 / 110°C
3 / 10 / 16 m
Information for order placements
Make Wilo
Type Stratos-D 40/1-8
Art no. 2090463
Weight approx. m 17 kg
Data sheet: Wilo-Stratos-D 40/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 11 / 30
Pump curves Δp-c (constant)
0 5 10 15 20 25
0 2 4 6 8
0 1 2 3 4 5 6
0
2
4
6
8
10
12
0
20
40
60
80
100
120
0 5 10 15 20 25
30
300
400
800
7
min.
H/m
P1/W
Q/m³/h
Q/l/s
Q/m³/h
max.
p/kPa
m/sv
Wilo-Stratos-D 40/1-121~230 V - DN 40
+
P1 Wilo-Stratos 40/1-12
max.
∆p-c
min.
1m2m
3m
4m
5m6m8m9m
11m12m
7m10m
Pump curves Δp-v (variable)
max.
0 5 10 15 20 25
0 2 4 6 8
0 1 2 3 4 5 6
0
4
8
12
0
40
80
120
0 5 10 15 20 250
400
800
30
7
30
H/m
P1/W
Q/m³/h
Q/l/s
Q/m³/h
p/kPa
m/sv
Wilo-Stratos-D 40/1-121~230 V - DN 40
+
max.
∆p-v
min.
P1 Wilo-Stratos 40/1-12min.
4m
5m6m8m
9m10m11m
7m
12m
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 40
Overall length l0 250 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 450.00 W
Speed n 1400 - 4600 rpm
Power consumption P1 25 - 550 W
Current consumption I 0.20 - 2.40 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPS - 40% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 40/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 12 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
252
14
41
51
145145
25
0
13
61
20
62
12
5
DN 40
Dimension drawing, flangeØ 150Ø 110
Ø 100
Ø 84
DN 40
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Minimum suction head at 50 / 95 / 110°C
5 / 12 / 18 m
Information for order placements
Make Wilo
Type Stratos-D 40/1-12
Art no. 2090464
Weight approx. m 25 kg
Data sheet: Wilo-Stratos-D 50/1-8
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 13 / 30
Pump curves Δp-c (constant)
0 5 10 15 20 25
0 2 4 6
0 1 2 3 4
0
2
4
6
8
0
20
40
60
80
0 5 10 15 20 25
200
400
600
0 min.
H/m
P1/W
max.
Wilo-Stratos-D 50/1-81~230 V - DN 50
p/kPa
m/sv
max.
∆p-c
+
P1 Wilo-Stratos 50/1-8
min.
Q/m³/h
Q/l/s
Q/m³/h
1m
2m
4m 3m5m6m8m 7m
Pump curves Δp-v (variable)
0 5 10 15 20 25
0 2 4 6
0 1 2 3 4
0
2
4
6
8
0
20
40
60
80
0 5 10 15 20 25
200
400
600
0
H/m
P1/W
Q/m³/h
Q/l/s
Q/m³/h
max.
Wilo-Stratos-D 50/1-81~230 V - DN 50
p/kPa
m/sv
+
min.
min.
P1 Wilo-Stratos 50/1-8
max.
∆p-v
3m4m5m6m7m
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 50
Overall length l0 240 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 200.00 W
Speed n 1400 - 4800 rpm
Power consumption P1 12 - 310 W
Current consumption I 0.22 - 1.37 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPS - 40% GF)
Pump shaft Stainless steel (X30CR13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 50/1-8
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 14 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
204
13
51
23
132113
24
0
12
01
06
61
12
0
DN 50
Dimension drawing, flangeØ 165Ø 125
Ø 110
Ø 99
DN 50
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Minimum suction head at 50 / 95 / 110°C
3 / 10 / 16 m
Information for order placements
Make Wilo
Type Stratos-D 50/1-8
Art no. 2090465
Weight approx. m 19 kg
Data sheet: Wilo-Stratos-D 50/1-9
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 15 / 30
Pump curves Δp-c (constant)
0 5 10 15 20 25 30
0 2 4 6 8
0 1 2 3 4
0
2
4
6
8
10
0
20
40
60
80
100
0 5 10 15 20 25 300
400
800
10
35
35
max.
P1 Wilo-Stratos 50/1-9
H/m
P1/W
Wilo-Stratos-D 50/1-91~230 V - DN 50
p/kPa
m/sv
max.
∆p-c
+
min.
Q/m³/h
Q/l/s
Q/m³/h
min.1m
2m
4m
3m
5m6m8m9m 7m
Pump curves Δp-v (variable)
0 5 10 15 20 25 30
0 2 4 6 8
0 1 2 3 4
0
2
4
6
8
0
20
40
60
80
5
0 5 10 15 20 25 30 35
35
10
0
400
800
v
Wilo-Stratos-D 50/1-91~230 V - DN 50
+
P1 Wilo-Stratos 50/1-9
H/m
P1/W
Q/m³/h
Q/l/s
Q/m³/h
max.
p/kPa
m/s
max.
∆p-v
min.
min.
3m
4m5m6m7m8m9m
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 50
Overall length l0 280 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 400.00 W
Speed n 1400 - 4100 rpm
Power consumption P1 25 - 490 W
Current consumption I 0.20 - 2.15 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPS - 40% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 50/1-9
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 16 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
256
14
81
59
145145
28
0
13
61
20
62
14
0
DN 50
Dimension drawing, flangeØ 165Ø 125
Ø 110
Ø 99
DN 50
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Minimum suction head at 50 / 95 / 110°C
5 / 12 / 18 m
Information for order placements
Make Wilo
Type Stratos-D 50/1-9
Art no. 2090466
Weight approx. m 27 kg
Data sheet: Wilo-Stratos-D 50/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 17 / 30
Pump curves Δp-c (constant)
0 10 20 30 40
0 2 4 6 8 10 12
0 1 2 3 4 5 6
0
2
4
6
8
10
12
0
20
40
60
80
100
120
0 10 20 30 400
400
1200
800
min.
H/m
P1/W
Wilo-Stratos-D 50/1-121~230 V - DN 50
p/kPa
m/sv
max.
∆p-c
+
P1 Wilo-Stratos 50/1-12
Q/m³/h
Q/l/s
Q/m³/h
max.
1m2m
3m
4m5m6m8m9m10m11m 7m
min.
Pump curves Δp-v (variable)
0 10 20 30 40
0 1 2 3 4 5 6
0
2
4
6
8
10
12
0
20
40
60
80
100
120
0 10 20 30 400
400
1200
800
0 2 4 6 8 10 12
H/m
P1/W
Q/m³/h
Q/m³/h
p/kPa
m/sv
min.
min.
Wilo-Stratos-D 50/1-121~230 V - DN 50
p/kPa
+
P1 Wilo-Stratos 50/1-12
max.
∆p-v
Q/l/s
max.
4m5m6m8m9m10m11m7m
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 50
Overall length l0 280 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 500.00 W
Speed n 1400 - 4600 rpm
Power consumption P1 25 - 590 W
Current consumption I 0.20 - 2.60 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPS - 40% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 50/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 18 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
256
14
81
59
145145
28
0
13
61
20
62
14
0
DN 50
Dimension drawing, flangeØ 165Ø 125
Ø 110
Ø 99
DN 50
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Minimum suction head at 50 / 95 / 110°C
5 / 12 / 18 m
Information for order placements
Make Wilo
Type Stratos-D 50/1-12
Art no. 2090467
Weight approx. m 27 kg
Data sheet: Wilo-Stratos-D 50/1-16
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 19 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
305
19
22
01
188188
34
0
16
31
56
70
17
0
DN 50
Dimension drawing, flangeØ 165
Ø 125
Ø 110
Ø 99
70
70
DN 50
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 50
Overall length l0 340 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 1050.00 W
Speed n 950 - 3400 rpm
Power consumption P1 40 - 1250 W
Current consumption I 0.30 - 5.50 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPE - 30% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 50/1-16
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 20 / 30
Minimum suction head at 50 / 95 / 110°C
7 / 15 / 23 m
Information for order placements
Make Wilo
Type Stratos-D 50/1-16
Art no. 2150598
Weight approx. m 48 kg
Data sheet: Wilo-Stratos-D 40/1-16
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 21 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
310
19
21
92
188188
25
0
16
31
56
65
12
5
DN 40
Dimension drawing, flangeØ 150
Ø 110
Ø 100
Ø 84
65
65
DN 40
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 40
Overall length l0 250 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 650.00 W
Speed n 950 - 3500 rpm
Power consumption P1 35 - 800 W
Current consumption I 0.30 - 3.50 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPE - 30% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 40/1-16
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 22 / 30
Minimum suction head at 50 / 95 / 110°C
7 / 15 / 23 m
Information for order placements
Make Wilo
Type Stratos-D 40/1-16
Art no. 2150597
Weight approx. m 44 kg
Data sheet: Wilo-Stratos-D 80/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 23 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
329
22
12
35
203203
36
0
16
41
56
100
18
0
DN 80
Dimension drawing, flangeØ 200
Ø 150
Ø 132
4 x Ø 19
DN 80
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6 bar
Pipe connections
Flange Flange PN 6 (PN 16 design,according to EN 1092-2)
Nominal flange diameter DN 80
Overall length l0 360 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 1300.00 W
Speed n 900 - 3300 rpm
Power consumption P1 40 - 1550 W
Current consumption I 0.30 - 6.80 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PP - 50% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 80/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 24 / 30
Minimum suction head at 50 / 95 / 110°C
7 / 15 / 23 m
Information for order placements
Make Wilo
Type Stratos-D 80/1-12
Art no. 2150600
Weight approx. m 61 kg
Data sheet: Wilo-Stratos-D 80/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 25 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
329
22
12
35
203203
36
0
16
41
56
100
18
0
DN 80
Dimension drawing, flangeØ 200
Ø 160
Ø 132
8 x Ø 19
DN 80
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 10 bar
Pipe connections
Flange Flange PN16 (according to EN1092-2)
Nominal flange diameter DN 80
Overall length l0 360 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 1300.00 W
Speed n 900 - 3300 rpm
Power consumption P1 40 - 1550 W
Current consumption I 0.30 - 6.80 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PP - 50% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 80/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 26 / 30
Minimum suction head at 50 / 95 / 110°C
7 / 15 / 23 m
Information for order placements
Make Wilo
Type Stratos-D 80/1-12
Art no. 2150601
Weight approx. m 61 kg
Data sheet: Wilo-Stratos-D 65/1-16
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 27 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
309
20
22
21
198198
34
0
16
31
56
80
17
0
DN 65
Dimension drawing, flangeØ 185
Ø 145
Ø 130
Ø 118
80
80
DN 65
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 65
Overall length l0 340 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 1200.00 W
Speed n 950 - 3400 rpm
Power consumption P1 40 - 1450 W
Current consumption I 0.30 - 6.40 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PPE - 30% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 65/1-16
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 28 / 30
Minimum suction head at 50 / 95 / 110°C
7 / 15 / 23 m
Information for order placements
Make Wilo
Type Stratos-D 65/1-16
Art no. 2150599
Weight approx. m 51 kg
Data sheet: Wilo-Stratos-D 65/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 29 / 30
Dimension drawing
Pg 7
Pg 9Pg 13,5
325
19
62
09
188188
34
0
16
41
56
88
17
0
DN 65
Dimension drawing, flangeØ 185Ø 145
Ø 130
Ø 118
DN 65
4 x Ø14
4 x Ø19
Terminal diagram
L1 L3
L2 L3
L1 L2
PE SSM
3~230 V, 50/60 Hz
L N PE SSM
1~ 230 V, 50/60 Hz
SSM:
Collective fault signal(NC contact according to VDI 3814, load capacity 1 A,250 V ~)For function, see Wilo catalogue, chapter "Pumpmanagement Wilo-Control, consulting guide"
Approved fluids (other fluids on request)
Heating water (in accordance with VDI2035)
•
Water-glycol mixtures (max. 1:1; above20% admixture, the pumping datamust be checked)
•
Permitted field of application
Temperature range at max. ambienttemperature +40 °C
-10...+110 °C
Maximum permissibleoperating pressure
Pmax 6/10 bar
Pipe connections
Flange Combination flange PN6/10 (PN16 flange according to EN1092-2)
Nominal flange diameter DN 65
Overall length l0 340 mm
Motor/electronics
Energy efficiency index (EEI) ≤ 0.27
Electromagnetic compatibility EN 61800-3
Emitted interference EN 61000-6-3
Interference resistance EN 61000-6-2
Speed control Frequency converter
Protection class IP X4D
Insulation class F
Mains connection 1~230 V, 50/60 Hz
Nominal motor power P2 650.00 W
Speed n 950 - 3300 rpm
Power consumption P1 38 - 800 W
Current consumption I 0.30 - 3.50 A
Motor protection integrated
Threaded cable connection PG 1x7/1x9/1x13.5
Materials
Pump housing Grey cast iron (EN-GJL-250)
Impeller Plastic (PP - 50% GF)
Pump shaft Stainless steel(X30Cr13/X46Cr13)
Bearing Carbon, metal impregnated
Minimum suction head at suction port for avoidingcavitation at water pumping temperature
Data sheet: Wilo-Stratos-D 65/1-12
Subject to change without prior notice. www.wilo.com 50 Hz 2015-03 30 / 30
Minimum suction head at 50 / 95 / 110°C
7 / 15 / 23 m
Information for order placements
Make Wilo
Type Stratos-D 65/1-12
Art no. 2150596