Transcript
Page 1: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Series description: Wilo-Economy MHIE

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 1 / 57

H/m

80

90

60

70

40

50

20

30

10

0Q/m³/h2015 302510

MHIE 200

MHIE 400

MHIE 800

50

Wilo-Economy MHIE50 / 60 Hz

MHIE1600

DesignNon-self-priming multistage pump with integrated frequency converter

ApplicationWater supply and pressure boosting•Fire extinguishing systems•Industrial circulation systems•Process engineering•Cooling water circulation systems•Washing and sprinkling systems•

Type keyExample: MHIE 402N-1/E/3-2/M13-2G

MHIEMultistage horizontal high-pressure centrifugal pump,electronically controlled

4 Volume flow in m3/h

02 Number of impellers

N IE2 motor

1Material1 = 1.4301 (AISI 304)2 = 1.4404 (AISI 316L)

EType of gasketE = EPDMV = FKM (Viton)

31 = 1~ (single-phase AC)3 = 3~ (three-phase AC)‐ = hydraulics without motor

M13

Only for 1~ (single phase AC)Preset operating mode on deliveryM13 = mode 1 or 3 (manual or remote control)M2 = mode 2 (pressure regulation mode)

2G Frequency converter, second generation

Special features/product advantagesEasy operation and compact design•All parts in contact with fluid are made of stainless steel•IEC three-phase motor (level IE2) with integrated frequency converter(frequency converter for 3~motors have optional interfaces for buscommunication using plug-in IF-Modules)

Full motor protection•All relevant components are KTW and WRAS approved•

Technical dataMains connection 1 ~ 230 V (±10 %), 50 Hz or 230 V  (±10 %), 60 Hz•Mains connection 3 ~ 400 V  (±10 %), 50 Hz (Y) or 400 V  (±10 %), 60Hz (Y)

Fluid temperature ‐15 to +110 °C•Max. operating pressure 10 bar•Max. inlet pressure 6 bar•Protection class IP 54•Emitted interference according to EN 61000-6-4 (EN 61000-6-3optionally)

Equipment/functionStainless steel pump in monobloc design•Hydraulics in 1.4301•Threaded connection•Integrated frequency converter•Three-phase version with red-button technology and LCD display forstate display

Integrated thermal motor protection•

MaterialsImpellers, stage chambers and pump housing stainless steel1.4301/1.4404

Shaft stainless steel 1.4404•Gasket EPDM (EP 851)/FKM (Viton)•Mechanical seal B-carbon/tungsten carbide•Bearing tungsten carbide•Pump base aluminium•

Scope of deliveryPump•Installation and operating instructions•

Page 2: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Series description: Wilo-Economy MHIE

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 2 / 57

Interference resistance in compliance with EN 61000-6-2•Nominal diameters of pipe connections on suction side to type Rp 1,Rp 1¼, Rp 1½ or Rp 2

Nominal diameters of pipe connections on pressure side to type Rp 1,Rp 1¼ or Rp 1½

Page 3: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Product list: Wilo-Economy MHIE

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 3 / 57

Type Mains connection Static seal Gross weight Nominal motorpower

Art no.

m / kg P2 / kW

MHIE 203N3~380/400/440 V,

50/60 HzEPDM 18.2 0.75 4171764

MHIE 203N3~380/400/440 V,

50/60 HzFKM 18.2 0.75 4171765

MHIE 205 M1, M31~220/230/240 V,

50/60 HzEPDM 18.2 1.1 4073100

MHIE 205 M1, M31~220/230/240 V,

50/60 HzFKM 18.2 1.1 4073104

MHIE 205 M21~220/230/240 V,

50/60 HzEPDM 18.2 1.1 4073101

MHIE 205 M21~220/230/240 V,

50/60 HzFKM 18.2 1.1 4073105

MHIE 205N-2G3~380/400/440 V,

50/60 HzEPDM 18.8 1.1 4148406

MHIE 205N-2G3~380/400/440 V,

50/60 HzFKM 18.8 1.1 4148407

MHIE 206N3~380/400/440 V,

50/60 HzEPDM 25.5 1.5 4171770

MHIE 206N3~380/400/440 V,

50/60 HzFKM 25.5 1.5 4171771

MHIE 402N3~380/400/440 V,

50/60 HzEPDM 18.2 0.75 4171776

MHIE 402N3~380/400/440 V,

50/60 HzFKM 18.2 0.75 4171777

MHIE 403 M1, M31~220/230/240 V,

50/60 HzEPDM 16.7 1.1 4073102

MHIE 403 M1, M31~220/230/240 V,

50/60 HzFKM 16.7 1.1 4073106

MHIE 403 M21~220/230/240 V,

50/60 HzEPDM 16.7 1.1 4073103

MHIE 403 M21~220/230/240 V,

50/60 HzFKM 16.7 1.1 4073107

MHIE 403N-2G3~380/400/440 V,

50/60 HzEPDM 18.8 1.1 4148412

MHIE 403N-2G3~380/400/440 V,

50/60 HzFKM 18.8 1.1 4148413

MHIE 404N3~380/400/440 V,

50/60 HzEPDM 23.8 1.5 4171782

MHIE 404N3~380/400/440 V,

50/60 HzFKM 23.8 1.5 4171783

MHIE 406N-2G3~380/400/440 V,

50/60 HzEPDM 26.6 2.2 4148418

MHIE 406N-2G3~380/400/440 V,

50/60 HzFKM 26.6 2.2 4148419

MHIE 802N3~380/400/440 V,

50/60 HzEPDM 23.1 1.5 4171788

MHIE 802N3~380/400/440 V,

50/60 HzFKM 23.1 1.5 4171789

MHIE 803N-2G3~380/400/440 V,

50/60 HzEPDM 25.4 2.2 4148424

MHIE 803N-2G3~380/400/440 V,

50/60 HzFKM 25.4 2.2 4148425

MHIE 1602N-2G3~380/400/440 V,

50/60 HzEPDM 27.5 2.2 4148430

Page 4: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M1, M3 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 4 / 57

Pump curves

0

10

20

30

40

50

60

70

H/m

0

0,4

0,8

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0

10

20

30

40

50

60

70

H/m

0

4

8

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

Δp-c

Δp-v

max.

0

20

40

η hyd./%

NPSH

η hyd.

Wilo-Economy MHIE 20550 / 60 Hz

Wilo-Economy MHIE 20550 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

min.

n=100%

n=80%

n=70%

n=60%

min.

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

158 51

Rp

1

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

252 87,5

460

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.7 kW

Nominal current 1~230 V, 50Hz

IN 14.1 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 205 M1, M3

Art no. 4073100

Weight approx. m 17.2 kg• = available, ‐ = not availableNote on inlet pressure

Page 5: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M1, M3 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 5 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 6: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M2 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 6 / 57

Pump curves

0

10

20

30

40

50

60

70

H/m

0

0,4

0,8

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0

10

20

30

40

50

60

70

H/m

0

4

8

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

Δp-c

Δp-v

max.

0

20

40

η hyd./%

NPSH

η hyd.

Wilo-Economy MHIE 20550 / 60 Hz

Wilo-Economy MHIE 20550 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

min.

n=100%

n=80%

n=70%

n=60%

min.

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

158 51

Rp

1

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

252 87,5

460

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.7 kW

Nominal current 1~230 V, 50Hz

IN 14.1 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 205 M2

Art no. 4073101

Weight approx. m 17.2 kg• = available, ‐ = not availableNote on inlet pressure

Page 7: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M2 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 7 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 8: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M1, M3 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 8 / 57

Pump curves

0

10

20

30

40

50

60

70

H/m

0

0,4

0,8

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0

10

20

30

40

50

60

70

H/m

0

4

8

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

Δp-c

Δp-v

max.

0

20

40

η hyd./%

NPSH

η hyd.

Wilo-Economy MHIE 20550 / 60 Hz

Wilo-Economy MHIE 20550 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

min.

n=100%

n=80%

n=70%

n=60%

min.

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

158 51

Rp

1

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

252 87,5

460

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.7 kW

Nominal current 1~230 V, 50Hz

IN 14.1 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 205 M1, M3

Art no. 4073104

Weight approx. m 17.2 kg• = available, ‐ = not availableNote on inlet pressure

Page 9: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M1, M3 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 9 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 10: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M2 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 10 / 57

Pump curves

0

10

20

30

40

50

60

70

H/m

0

0,4

0,8

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0

10

20

30

40

50

60

70

H/m

0

4

8

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

Δp-c

Δp-v

max.

0

20

40

η hyd./%

NPSH

η hyd.

Wilo-Economy MHIE 20550 / 60 Hz

Wilo-Economy MHIE 20550 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

min.

n=100%

n=80%

n=70%

n=60%

min.

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

158 51

Rp

1

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

252 87,5

460

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.7 kW

Nominal current 1~230 V, 50Hz

IN 14.1 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 205 M2

Art no. 4073105

Weight approx. m 17.2 kg• = available, ‐ = not availableNote on inlet pressure

Page 11: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205 M2 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 11 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 12: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 12 / 57

Pump curves

0

10

20

30

40

50

60

70

H/m

0

0,4

0,8

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0

10

20

30

40

50

60

70

H/m

0

4

8

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

Δp-c

Δp-v

max.

0

20

40

η hyd./%

NPSH

η hyd.

Wilo-Economy MHIE 20550 / 60 Hz

Wilo-Economy MHIE 20550 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

min.

n=100%

n=80%

n=70%

n=60%

min.

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0253

ø1/4"

Rp

1

90

10

4,0

32

1,0 ø1/4"

158 51

ø 1

46

Rp 1

7ø9

108190 457

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.4 kW

Nominal current 3~400 V, 50Hz

IN 3.3 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.2 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

82.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 205N-2G

Page 13: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 13 / 57

Art no. 4148406

Weight approx. m 16.6 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 14: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 14 / 57

Pump curves

0

10

20

30

40

50

60

70

H/m

0

0,4

0,8

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0

10

20

30

40

50

60

70

H/m

0

4

8

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

Δp-c

Δp-v

max.

0

20

40

η hyd./%

NPSH

η hyd.

Wilo-Economy MHIE 20550 / 60 Hz

Wilo-Economy MHIE 20550 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

min.

n=100%

n=80%

n=70%

n=60%

min.

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0253

ø1/4"

Rp

1

90

10

4,0

32

1,0 ø1/4"

158 51

ø 1

46

Rp 1

7ø9

108190 457

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.4 kW

Nominal current 3~400 V, 50Hz

IN 3.3 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.2 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

82.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 205N-2G

Page 15: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 205N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 15 / 57

Art no. 4148407

Weight approx. m 16.6 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 16: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M1, M3 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 16 / 57

Pump curves

0

10

20

30

40

H/m

0

10

20

30

40

H/m

0

0,4

0,8

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=80%

n=100%

n=60%n=70%

n=80%

n=90%

n=70%

min.

min.

Δp-c

Wilo-Economy MHIE 40350 / 60 Hz

Wilo-Economy MHIE 40350 / 60 Hz

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

110 51

Rp

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

204 87,5

412

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.5 kW

Nominal current 1~230 V, 50Hz

IN 12.7 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 403 M1, M3

Art no. 4073102

Weight approx. m 15.7 kg• = available, ‐ = not availableNote on inlet pressure

Page 17: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M1, M3 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 17 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 18: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M2 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 18 / 57

Pump curves

0

10

20

30

40

H/m

0

10

20

30

40

H/m

0

0,4

0,8

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=80%

n=100%

n=60%n=70%

n=80%

n=90%

n=70%

min.

min.

Δp-c

Wilo-Economy MHIE 40350 / 60 Hz

Wilo-Economy MHIE 40350 / 60 Hz

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

110 51

Rp

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

204 87,5

412

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.5 kW

Nominal current 1~230 V, 50Hz

IN 12.7 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 403 M2

Art no. 4073103

Weight approx. m 15.7 kg• = available, ‐ = not availableNote on inlet pressure

Page 19: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M2 (1~220/230/240 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 19 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 20: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M1, M3 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 20 / 57

Pump curves

0

10

20

30

40

H/m

0

10

20

30

40

H/m

0

0,4

0,8

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=80%

n=100%

n=60%n=70%

n=80%

n=90%

n=70%

min.

min.

Δp-c

Wilo-Economy MHIE 40350 / 60 Hz

Wilo-Economy MHIE 40350 / 60 Hz

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

110 51

Rp

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

204 87,5

412

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.5 kW

Nominal current 1~230 V, 50Hz

IN 12.7 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 403 M1, M3

Art no. 4073106

Weight approx. m 15.7 kg• = available, ‐ = not availableNote on inlet pressure

Page 21: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M1, M3 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 21 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 22: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M2 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 22 / 57

Pump curves

0

10

20

30

40

H/m

0

10

20

30

40

H/m

0

0,4

0,8

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=80%

n=100%

n=60%n=70%

n=80%

n=90%

n=70%

min.

min.

Δp-c

Wilo-Economy MHIE 40350 / 60 Hz

Wilo-Economy MHIE 40350 / 60 Hz

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

Ø 9

108

190

150

180

Rp 1

110 51

Rp

10

4,0

90

Ø 1/4"

Ø 1/4"

28

4,0

Ø 1

55

37

52

8,5

204 87,5

412

Terminal diagram

+ 2

4 V

+ 2

4 V

+ 1

0 V

0 V

L N PE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 1~220/230/240 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.5 kW

Nominal current 1~230 V, 50Hz

IN 12.7 A

Nominal current 1~240 V, 60Hz

I 11.2 A

Nominal current 1~220 V, 60Hz

I 11.9 A

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 403 M2

Art no. 4073107

Weight approx. m 15.7 kg• = available, ‐ = not availableNote on inlet pressure

Page 23: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403 M2 (1~220/230/240 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 23 / 57

The maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 24: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 24 / 57

Pump curves

0

10

20

30

40

H/m

0

10

20

30

40

H/m

0

0,4

0,8

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=80%

n=100%

n=60%n=70%

n=80%

n=90%

n=70%

min.

min.

Δp-c

Wilo-Economy MHIE 40350 / 60 Hz

Wilo-Economy MHIE 40350 / 60 Hz

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0205

ø1/4"

Rp

90

10

4,0

32

1,0 ø1/4"

110 51

ø 1

46

Rp 1

7ø9

108190 457

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.4 kW

Nominal current 3~400 V, 50Hz

IN 3.3 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.2 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

82.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 403N-2G

Page 25: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 25 / 57

Art no. 4148412

Weight approx. m 16.6 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 26: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 406N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 26 / 57

Pump curves

0

20

40

60

80

H/m

0

20

40

60

80

H/m

0

0,5

1,0

1,5

2,0P2 /kW

0

5

15

10

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

NPSH

η hyd.

Δp-v max.

Δp-c

Wilo-Economy MHIE 40650 / 60 Hz

n=100%

n=60%

n=50%

min.

n=90%n=80%

n=70%

min.

n=60%n=70%

n=80%n=90%

n=50%

n=100%

Wilo-Economy MHIE 40650 / 60 Hz

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0277

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

182 51

ø 1

72

Rp 1

7ø9

108190 523

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 2.20 kW

Power consumption P1 2.6 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.7 A

Nominal current 3~440 V, 60Hz

I 5.5 A

Motor efficiency ηm50%

81.0 %

Motor efficiency ηm75%

84.0 %

Motor efficiency ηm100%

85.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 406N-2G

Page 27: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 406N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 27 / 57

Art no. 4148418

Weight approx. m 24.4 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 28: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 28 / 57

Pump curves

0

10

20

30

40

H/m

0

10

20

30

40

H/m

0

0,4

0,8

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=80%

n=100%

n=60%n=70%

n=80%

n=90%

n=70%

min.

min.

Δp-c

Wilo-Economy MHIE 40350 / 60 Hz

Wilo-Economy MHIE 40350 / 60 Hz

n=90%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0205

ø1/4"

Rp

90

10

4,0

32

1,0 ø1/4"

110 52

ø 1

46

Rp 1

7ø9

108190 457

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.10 kW

Power consumption P1 1.4 kW

Nominal current 3~400 V, 50Hz

IN 3.3 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.2 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

82.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 403N-2G

Page 29: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 403N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 29 / 57

Art no. 4148413

Weight approx. m 16.6 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 30: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 406N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 30 / 57

Pump curves

0

20

40

60

80

H/m

0

20

40

60

80

H/m

0

0,5

1,0

1,5

2,0P2 /kW

0

5

15

10

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

60

η hyd./%

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

NPSH

η hyd.

Δp-v max.

Δp-c

Wilo-Economy MHIE 40650 / 60 Hz

n=100%

n=60%

n=50%

min.

n=90%n=80%

n=70%

min.

n=60%n=70%

n=80%n=90%

n=50%

n=100%

Wilo-Economy MHIE 40650 / 60 Hz

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0277

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

182 52

ø 1

72

Rp 1

7ø9

108190 523

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 2.20 kW

Power consumption P1 2.6 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.7 A

Nominal current 3~440 V, 60Hz

I 5.5 A

Motor efficiency ηm50%

81.0 %

Motor efficiency ηm75%

84.0 %

Motor efficiency ηm100%

85.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 406N-2G

Page 31: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 406N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 31 / 57

Art no. 4148419

Weight approx. m 24.4 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 32: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 803N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 32 / 57

Pump curves

0

10

20

30

40

50

H/m

0

10

20

30

40

50

H/m

0

0,5

1,0

1,5

2,0P2 /kW

0

2

4

6

NPSH/m

0 4 8 12 16 20 Q/m³/h

0 4 8 12 16 20 Q/m³/h

0 4 8 12 16 20 Q/m³/h

0 4 8 12 16 20 Q/m³/h

0 1 2 3 4 5 6 Q/l/s

0

20

40

60

η hyd./%

NPSH

Δp-v

max.

min.

n=90%

n=80%

n=70%

min.

Wilo-Economy MHIE 80350 / 60 Hz

Wilo-Economy MHIE 80350 / 60 Hz

n=50%

n=100%

n=60%n=70%

n=80%

n=90%

Δp-c

n=100%

n=60%

η hyd.

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0217

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

122 52

ø 1

72

Rp 1¼

7ø9

108190 463

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 2.20 kW

Power consumption P1 2.6 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.7 A

Nominal current 3~440 V, 60Hz

I 5.5 A

Motor efficiency ηm50%

81.0 %

Motor efficiency ηm75%

84.0 %

Motor efficiency ηm100%

85.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1¼

Nominal diameter, oval flange (on thesuction side)

G 1½

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 803N-2G

Page 33: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 803N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 33 / 57

Art no. 4148424

Weight approx. m 23.2 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 34: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 803N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 34 / 57

Pump curves

0

10

20

30

40

50

H/m

0

10

20

30

40

50

H/m

0

0,5

1,0

1,5

2,0P2 /kW

0

2

4

6

NPSH/m

0 4 8 12 16 20 Q/m³/h

0 4 8 12 16 20 Q/m³/h

0 4 8 12 16 20 Q/m³/h

0 4 8 12 16 20 Q/m³/h

0 1 2 3 4 5 6 Q/l/s

0

20

40

60

η hyd./%

NPSH

Δp-v

max.

min.

n=90%

n=80%

n=70%

min.

Wilo-Economy MHIE 80350 / 60 Hz

Wilo-Economy MHIE 80350 / 60 Hz

n=50%

n=100%

n=60%n=70%

n=80%

n=90%

Δp-c

n=100%

n=60%

η hyd.

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0217

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

122 52

ø 1

72

Rp 1¼

7ø9

108190 463

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 2.20 kW

Power consumption P1 2.6 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.7 A

Nominal current 3~440 V, 60Hz

I 5.5 A

Motor efficiency ηm50%

81.0 %

Motor efficiency ηm75%

84.0 %

Motor efficiency ηm100%

85.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1¼

Nominal diameter, oval flange (on thesuction side)

G 1½

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 803N-2G

Page 35: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 803N-2G (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 35 / 57

Art no. 4148425

Weight approx. m 23.2 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 36: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 1602N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 36 / 57

Pump curves

0 5 10 15 20 25 30 35 Q/m³/h

0 5 10 15 20 25 30 35 Q/m³/h

0 2 4 6 8 10 Q/l/s

0

5

10

15

20

25

30

H/m

0

5

10

15

20

25

30

H/m

0

0,5

1,0

1,5

2,0P2 /kW

0

4

8

NPSH/m

0 5 10 15 20 25 30 35 Q/m³/h

0 5 10 15 20 25 30 35 Q/m³/h

0

20

40

60

η hyd./%

NPSH

η hyd.

max.

Δp-c

Wilo-Economy MHIE 160250 / 60 Hz

Wilo-Economy MHIE 160250 / 60 Hz

min.

n=100%

n=60%

n=70%

n=80%

n=90%

n=100%

min. n=60%

n=70%n=80%

n=90%

Δp-v

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0236

ø1/4"

Rp

2

90

10

5,0

34

1,0 ø1/4"

138 55

ø 1

72

Rp 1½

7ø9

108190 482

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 2.20 kW

Power consumption P1 2.6 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.7 A

Nominal current 3~440 V, 60Hz

I 5.5 A

Motor efficiency ηm50%

81.0 %

Motor efficiency ηm75%

84.0 %

Motor efficiency ηm100%

85.5 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1½

Nominal diameter, oval flange (on thesuction side)

G 2

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 1602N-2G

Page 37: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 1602N-2G (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 37 / 57

Art no. 4148430

Weight approx. m 25.3 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 38: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 402N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 38 / 57

Pump curves

0

5

10

15

20

25

30

H/m

0

5

10

15

20

25

30

H/m

0

0,2

0,4

0,6

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

Δp-v max.

0

20

40

η hyd./%

NPSH

η hyd.

n=100%

n=60%

n=50%

n=80%

n=70%

min.

min.

n=100%

n=60%n=70%

n=80%

n=90%

Wilo-Economy MHIE 40250 / 60 Hz

Wilo-Economy MHIE 40250 / 60 HzΔp-c

n=90%

n=50%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0204

ø1/4"

Rp

90

10

4,0

32

1,0 ø1/4"

110 51

ø 1

46

Rp 1

7ø9

108190 409

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 0.75 kW

Power consumption P1 0.96 kW

Nominal current 3~400 V, 50Hz

IN 3.2 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.1 A

Motor efficiency ηm50%

74.0 %

Motor efficiency ηm75%

78.0 %

Motor efficiency ηm100%

79.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 402N

Page 39: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 402N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 39 / 57

Art no. 4171776

Weight approx. m 16.0 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 40: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 402N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 40 / 57

Pump curves

0

5

10

15

20

25

30

H/m

0

5

10

15

20

25

30

H/m

0

0,2

0,4

0,6

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

Δp-v max.

0

20

40

η hyd./%

NPSH

η hyd.

n=100%

n=60%

n=50%

n=80%

n=70%

min.

min.

n=100%

n=60%n=70%

n=80%

n=90%

Wilo-Economy MHIE 40250 / 60 Hz

Wilo-Economy MHIE 40250 / 60 HzΔp-c

n=90%

n=50%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0204

ø1/4"

Rp

90

10

4,0

32

1,0 ø1/4"

110 51

ø 1

46

Rp 1

7ø9

108190 409

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 0.75 kW

Power consumption P1 0.96 kW

Nominal current 3~400 V, 50Hz

IN 3.2 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.1 A

Motor efficiency ηm50%

74.0 %

Motor efficiency ηm75%

78.0 %

Motor efficiency ηm100%

79.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 402N

Page 41: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 402N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 41 / 57

Art no. 4171777

Weight approx. m 16.0 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 42: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 404N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 42 / 57

Pump curves

0

10

20

30

40

50

60

H/m

0

10

20

30

40

50

60

H/m

0

0,5

1,0

1,5

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

η hyd./%

Q/m³/h

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=50%

n=100%

n=60%n=70%

n=80%n=90%

min.

min.

Δp-c

Wilo-Economy MHIE 40450 / 60 Hz

Wilo-Economy MHIE 40450 / 60 Hz

n=90%

n=80%

n=70%

n=50%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0252

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

158 51

ø 1

72

Rp 1

7ø9

108190 499

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.50 kW

Power consumption P1 1.89 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.8 A

Nominal current 3~440 V, 60Hz

I 5.4 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

84.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 404N

Page 43: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 404N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 43 / 57

Art no. 4171782

Weight approx. m 21.6 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 44: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 404N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 44 / 57

Pump curves

0

10

20

30

40

50

60

H/m

0

10

20

30

40

50

60

H/m

0

0,5

1,0

1,5

P2 /kW

0

4

8

NPSH/m

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10 Q/m³/h

0 2 4 6 8 10

0 0,5 1,0 1,5 2,0 2,0 2,5 Q/l/s

0

20

40

η hyd./%

Q/m³/h

NPSH

η hyd.

Δp-v max.

n=100%

n=60%

n=50%

n=100%

n=60%n=70%

n=80%n=90%

min.

min.

Δp-c

Wilo-Economy MHIE 40450 / 60 Hz

Wilo-Economy MHIE 40450 / 60 Hz

n=90%

n=80%

n=70%

n=50%

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0252

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

158 51

ø 1

72

Rp 1

7ø9

108190 499

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.50 kW

Power consumption P1 1.89 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.8 A

Nominal current 3~440 V, 60Hz

I 5.4 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

84.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1¼

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 404N

Page 45: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 404N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 45 / 57

Art no. 4171783

Weight approx. m 21.6 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 46: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 802N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 46 / 57

Pump curves

0

5

10

15

20

25

30

35

H/m

0

5

10

15

20

25

30

35

H/m

0

0,5

1,0

1,5

P2 /kW

0

2

4

6

NPSH/m

0 4 8 12 16 Q/m³/h

0 4 8 12 16 Q/m³/h

0 4 8 12 16 Q/m³/h

0 4 8 12 16 Q/m³/h

0 1 2 3 4 5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v

max.

n=60%

min.

n=90%

n=80%

n=70%

n=100%

min. n=50%

Wilo-Economy MHIE 80250 / 60 Hz

Wilo-Economy MHIE 80250 / 60 Hz

n=50%

n=100%

n=60%n=70%

n=80%n=90%

Δp-c

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0216

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

122 51

ø 1

72

Rp 1¼

7ø9

108190 463

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.50 kW

Power consumption P1 1.89 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.8 A

Nominal current 3~440 V, 60Hz

I 5.4 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

84.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1¼

Nominal diameter, oval flange (on thesuction side)

G 1½

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 802N

Page 47: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 802N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 47 / 57

Art no. 4171788

Weight approx. m 20.9 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 48: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 802N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 48 / 57

Pump curves

0

5

10

15

20

25

30

35

H/m

0

5

10

15

20

25

30

35

H/m

0

0,5

1,0

1,5

P2 /kW

0

2

4

6

NPSH/m

0 4 8 12 16 Q/m³/h

0 4 8 12 16 Q/m³/h

0 4 8 12 16 Q/m³/h

0 4 8 12 16 Q/m³/h

0 1 2 3 4 5 Q/l/s

0

20

40

60

η hyd./%

NPSH

η hyd.

Δp-v

max.

n=60%

min.

n=90%

n=80%

n=70%

n=100%

min. n=50%

Wilo-Economy MHIE 80250 / 60 Hz

Wilo-Economy MHIE 80250 / 60 Hz

n=50%

n=100%

n=60%n=70%

n=80%n=90%

Δp-c

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0216

ø1/4"

Rp

90

10

4,0

34

1,0 ø1/4"

122 51

ø 1

72

Rp 1¼

7ø9

108190 463

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.50 kW

Power consumption P1 1.89 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.8 A

Nominal current 3~440 V, 60Hz

I 5.4 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

84.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1¼

Nominal diameter, oval flange (on thesuction side)

G 1½

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 802N

Page 49: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 802N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 49 / 57

Art no. 4171789

Weight approx. m 20.9 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 50: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 203N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 50 / 57

Pump curves

0

10

20

30

40

H/m

0

0,2

0,4

0,6

P2 /kW

0

10

20

30

40

H/m

0

2

4

6NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

0

10

20

30

40η hyd./%

Δp-v

Δp-c

max.

NPSH

η hyd.

n=100%

n=60%

n=70%

n=90%

n=50%

min.

Wilo-Economy MHIE 20350 / 60 Hz

Wilo-Economy MHIE 20350 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

n=50%

n=80%

min.

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0204

ø1/4"

Rp

1

90

10

4,0

32

1,0 ø1/4"

110 51

ø 1

46

Rp 1

7ø9

108190 409

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 0.75 kW

Power consumption P1 0.96 kW

Nominal current 3~400 V, 50Hz

IN 3.2 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.1 A

Motor efficiency ηm50%

74.0 %

Motor efficiency ηm75%

78.0 %

Motor efficiency ηm100%

79.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 203N

Page 51: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 203N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 51 / 57

Art no. 4171764

Weight approx. m 16.0 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 52: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 203N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 52 / 57

Pump curves

0

10

20

30

40

H/m

0

0,2

0,4

0,6

P2 /kW

0

10

20

30

40

H/m

0

2

4

6NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

0

10

20

30

40η hyd./%

Δp-v

Δp-c

max.

NPSH

η hyd.

n=100%

n=60%

n=70%

n=90%

n=50%

min.

Wilo-Economy MHIE 20350 / 60 Hz

Wilo-Economy MHIE 20350 / 60 Hz

n=100%

n=60%n=70%

n=80%

n=90%

n=50%

n=80%

min.

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

110,0204

ø1/4"

Rp

1

90

10

4,0

32

1,0 ø1/4"

110 51

ø 1

46

Rp 1

7ø9

108190 409

158

198

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 0.75 kW

Power consumption P1 0.96 kW

Nominal current 3~400 V, 50Hz

IN 3.2 A

Nominal current 3~380 V, 60Hz

I 3.4 A

Nominal current 3~440 V, 60Hz

I 3.1 A

Motor efficiency ηm50%

74.0 %

Motor efficiency ηm75%

78.0 %

Motor efficiency ηm100%

79.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 203N

Page 53: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 203N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 53 / 57

Art no. 4171765

Weight approx. m 16.0 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 54: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 206N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 54 / 57

Pump curves

0

20

40

60

80

H/m

0

0,5

1,0

1,5

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

n=100%

n=90%

0

20

40

60

80

H/m Δp-c

max.

0

4

2

6

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

0

20

10

40

30

η hyd./%

NPSH

η hyd.

n=80%

n=70%

n=60%

n=50%

min.

n=100%

n=60%n=50%

n=70%n=80%

n=90%

min.

Δp-v

Wilo-Economy MHIE 20650 / 60 Hz

Wilo-Economy MHIE 20650 / 60 Hz

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0276

ø1/4"

Rp

1

90

10

4,0

34

1,0 ø1/4"

182 51

ø 1

72

Rp 1

7ø9

108190 523

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+110 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.50 kW

Power consumption P1 1.89 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.8 A

Nominal current 3~440 V, 60Hz

I 5.4 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

84.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4301 [AISI304]

Pump housing 1.4301 [AISI304]

Pump shaft 1.4301 [AISI304]

Static seal EPDM

Mechanical seal BQ1E3GG

Information for order placements

Make Wilo

Type MHIE 206N

Page 55: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 206N (3~380/400/440 V, EPDM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 55 / 57

Art no. 4171770

Weight approx. m 23.3 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.

Page 56: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 206N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 56 / 57

Pump curves

0

20

40

60

80

H/m

0

0,5

1,0

1,5

P2 /kW

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

n=100%

n=90%

0

20

40

60

80

H/m Δp-c

max.

0

4

2

6

NPSH/m

0 1 2 3 4 5 6 Q/m³/h

0 1 2 3 4 5 6 Q/m³/h

0 0,4 0,8 1,2 1,6 Q/l/s

0

20

10

40

30

η hyd./%

NPSH

η hyd.

n=80%

n=70%

n=60%

n=50%

min.

n=100%

n=60%n=50%

n=70%n=80%

n=90%

min.

Δp-v

Wilo-Economy MHIE 20650 / 60 Hz

Wilo-Economy MHIE 20650 / 60 Hz

Pump curves in accordance with ISO 9906, class 2

Dimension drawing

528,5

148,0276

ø1/4"

Rp

1

90

10

4,0

34

1,0 ø1/4"

182 51

ø 1

72

Rp 1

7ø9

108190 523

182

222

Terminal diagram

aux

off

MP

DDS

20mA

+24V

In1GND

SBM SSM

SBM SSM

GND

In2

ON

L3L2

L1

Power

Fluid temperature T -15...+90 °C

Max. ambient temperature T 50 °C

Rated pressure PN  bar

Inlet pressure Max. H 6 bar

Maximum operating pressure pmax 10 bar

Motor

Insulation class F

Protection class IP 54

Mains connection 3~380/400/440 V, 50/60 Hz

Nominal motor power P2 1.50 kW

Power consumption P1 1.89 kW

Nominal current 3~400 V, 50Hz

IN 5.6 A

Nominal current 3~380 V, 60Hz

I 5.8 A

Nominal current 3~440 V, 60Hz

I 5.4 A

Motor efficiency ηm50%

79.0 %

Motor efficiency ηm75%

82.0 %

Motor efficiency ηm100%

84.0 %

Connections

Nominal diameter, oval flange (on thepressure side)

G 1

Nominal diameter, oval flange (on thesuction side)

G 1

Rated pressure level (on thepressure side)

PN PN 10

Rated pressure level (on thesuction side)

PN PN 10

Materials

Impeller 1.4404 [AISI316L]

Pump housing 1.4404 [AISI316L]

Pump shaft 1.4404 [AISI316L]

Static seal FKM

Mechanical seal Q1BVGG

Information for order placements

Make Wilo

Type MHIE 206N

Page 57: Series description: Wilo-Economy MHIE · Series description: Wilo-Economy MHIE Subject to change without prior notice. 50 Hz 2015-02 1 / 57 H/m 80 90 60 70 40 50 20 30 10 0 10 15

Data sheet: Wilo-Economy MHIE 206N (3~380/400/440 V, FKM)

Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 57 / 57

Art no. 4171771

Weight approx. m 23.3 kg• = available, ‐ = not availableNote on inlet pressureThe maximum inlet pressure is calculated by subtracting the maximumdelivery head of the pump at Q= 0 from the maximum operating pressureof the system.Note on materials1.4301 corresponds to AISI 304, 1.4404 corresponds to AISI 316L.