Schneider Electric: Total Cooling Solutions for Data Centers
Nestor Hugo Salinas, ATD #
Solution Architect
![Page 2: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/2.jpg)
Schneider Electric 2
Power Flow in a Typical Data Center
41% Cooling
PUE = 2.13DCiE= 47%Source:
WP # 126: An improved architecture for high efficiency, high density data center
![Page 3: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/3.jpg)
Schneider Electric 3
Data Center Cooling Trends
• Close Coupled Cooling• Higher Temperature Operation• Free Cooling• Evaporative or Adiabatic Cooling• Containment Cooling• Chimney Racks and Ceiling Plenums• Dew Point Humidity Control• Non-integrated Humidification• Intelligent Management Systems
Efficiency
Increased Temperatures
Economizers
![Page 4: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/4.jpg)
Schneider Electric 5
3 Cooling Architectures
Source:WP # 130: The advantages of row and rack oriented cooling architectures for data centers
** NMX-J-C-I-489-ANCE-ONNCE –NYCE-2014
• Rack density**:• Low: up to 3 kW• Medium: 3kW < X < 8kW• High: 8kW < X < 15kW• Extreme: >15kW
![Page 5: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/5.jpg)
Schneider Electric 6
Hibryd Cooling Solutions
Overhead CoolingRow Cooling
Room CoolingNeutral Containment
Chillers
Heat rejection
![Page 6: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/6.jpg)
Schneider Electric 7
How can we help you
![Page 7: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/7.jpg)
Schneider Electric 8
Design tools:Configuration – ISX Designer
● Directions:● Contact APC Sales● Engage Local Representative● APC implements requirements
with pre-tested solutions from configurator
● APC Configuration team addresses unique requirements
![Page 8: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/8.jpg)
Schneider Electric 9
Design tools: StruxureWare - EcoStream
![Page 9: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/9.jpg)
Schneider Electric 10
Improve Performance: Air Distribution
![Page 10: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/10.jpg)
Schneider Electric 11
Low density: Room Cooling
• DX and CW• 20 – 100 kW DX units• 20 – 190 kW CW units
• High Effiency
• EC Fans technology
• Frontal Access
• R410A refrigerant
• Electronic Expansion Valve integrated with Uniflair control
• Tandem compressors to increase unit efficiency at partial loads
• Energy Saving and Twin versions
• 208V and 480V
http://www.uniflair.com/coolingfordatacenter/
![Page 11: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/11.jpg)
Schneider Electric 12
Medium / High Density: Row Cooling
http://www.uniflair.com/coolingfordatacenter/
![Page 12: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/12.jpg)
Schneider Electric 13
InRow® Cooling Leader
InRow® Chilled Water InRow® Direct Expansion
![Page 13: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/13.jpg)
14Schneider Electric
InRow® Cooling Overhead
• InRow® Pumped Refrigerant R134A
• White Space is not required
• Up to 27kW per unit
• Up to 160kW per system
• High Availability
![Page 14: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/14.jpg)
15Schneider Electric
High / Extreme density: EcoAisle®
• Options available to support (900mm, 1200mm,1500mm, and 1800mm aisle widths )
• Panels Can also be modified in the field to fit odd aisle sizes
• Ceiling panels support hot or cold aisles
• Safe Slide Doors support hot or cold aisles
• Blank Panels available for 300, 600, 700, and 750mm wide spaces
http://www.uniflair.com/coolingfordatacenter/
![Page 15: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/15.jpg)
16Schneider Electric
EcoAisle options
• Ducted hot/cold aisle• Fire safe System• LED Lighting • Curtain / Sliding safe Door
![Page 16: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/16.jpg)
17Schneider Electric
EcoAisle Fire Safe System
![Page 17: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/17.jpg)
18Schneider Electric
High / Extreme density: Rack Containment
![Page 18: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/18.jpg)
Schneider Electric 19
Indirect Free Cooling - EcoBreeze®An Indirect Evaporative Air-Side Economizer with typical
partial PUE of 1.09 to 1.20
![Page 19: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/19.jpg)
Schneider Electric 20
Free Cooling - EcoBreeze®
![Page 20: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/20.jpg)
Schneider Electric 22
Close Control Air Conditioning for Mobile Telecommunications
• Easy & quick installation• Refrigerant charged in factory• Complete final testing of unit in factory• Reduced installation time • Reliable and trouble-free operation • SCROLL compressor• Low noise operation
• R407C or R134a refrigerant
• Supervision system:
• via serial line RS485 – TCP/IP
![Page 21: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/21.jpg)
Schneider Electric 23
Mobile Telecom units – Product Range
![Page 22: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/22.jpg)
Schneider Electric 24
Chiller Water Units• R410A & R134a refrigerant• Electronic Expansion Valve integrated with Uniflair control• EC Fans (Electronic Commutation)• Free Cooling• Tandem Compressors
• Inverter driven scroll compressors• Centrifugal compressors• Double Screw compressors
![Page 23: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/23.jpg)
Schneider Electric 25
0
200
400
600
800
1000
1200
kW
Chiller Water units: Product Range
![Page 24: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/24.jpg)
Schneider Electric 26
Prefabricated Solutions
![Page 25: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/25.jpg)
Schneider Electric 27
Schneider Electric Cooling Portfolio
RowR
ack
•Amico•Leonardo•Wall-mounted•Monoblock•Gemini•Unisplit•InRoom SC •Room Air Distribution
•Rack Air Distribution
•InRack Direct Expansion
•Chimeneas
•InRow Chilled Water
•InRow Direct Expansion
•InRow OA/RA Pumped Refrigerant
•Thermal Containment
•Access Flooring•Technical Chillers•Free Cooling, Chillers and Economizers
•Ecoflair®•Heat RejectionRoom
![Page 26: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect](https://reader036.vdocuments.us/reader036/viewer/2022081418/56649f385503460f94c552d1/html5/thumbnails/26.jpg)
Schneider Electric
Make the most of your energy™
Nestor Hugo Salinas