Samsung TechwinAccess Control Sales Presentation
2010
Contents
• Introduction to Access Control and User Credentials• Standalone Controllers• Control Panels• Readers• Accessories• Part Codes• System Configurations• Appendix – Technical Data
Introduction
• Access control is a system which enables an authority to control access to areas and resources in a given physical facility.
• Conditions of granted accessWHOM
WHEREHOW
WHEN
Controlled Access Points
Authorized IndividualsSpecific Time Parameters
User Credentials
Introduction to Access Control
Lock and Key• Can secure a door.• Key will always open lock,
regardless of time.• Lost key requires lock
replacement.• No audit of granted access.• Bunches of keys are heavy to
carry.• Losing a bunch of keys
requires many expensive lock changes
Electronic Access Control• Can secure a door.• Time profiles can be added to access
levels.• Lost card key can be deactivated.• Any card can open one or all doors.• Full audit trail of successful and
denied access.• No need to replace working locks.• Door monitoring to signal ‘Door Held’
or ‘Forced’ open.• Credentials can be combined for
higher levels of security, card key, PIN number, biometric.
Samsung Techwin Access Control - Credentials
Low •Physical / Tangible Object.•Example – a card key.
Med •Something you know.•Example - a PIN .
High •Something you have.•Example – a fingerprint.
Samsung Techwin Access Control – Solutions Range
STANDALONE RANGE Entry Level, single credential standalone. Medium Secure, duel credential standalone. High Security, triple credential standalone. PC Connection possible for Time &Attendance readers. SOFTWARE, INTELLEGENT CONTROLLERS AND READERS Scalable software built on SQL Server 2005. Distributed processing. 1,2,3 and 4 door intelligent control. Proximity / Smart Card, PIN and Biometric Readers. TCP/IP Networked. Video Integration. Command and Control.
Samsung Techwin Access Control• The Samsung Access Control Range offers aesthetically designed
products built to increasing design specifications to provide a cost effective security solution tailored to an individuals need and budget.
• The standalone range offers the most cost effective small system solution and has high security options , utilising fingerprint recognition in conjunction with PIN and proximity for the most secure environments.
• Beyond the standalone range is the Samsung Access Management System – SAMS – which is built on a SQL Server database structure and includes multiple communication protocols, video integration, command and control, reporting and language options for medium to large businesses.
What are Standalone Controllers?Standalone controllers:
• do not require a connection to a computer .
• can be programmed locally once the unit is installed and has power connected.
• card key administration can be performed locally at the device
Properties of Standalone Controllers
• Cost effective complete door control.
• Proximity / Smart Card, PIN, Password and Fingerprint options.
• Direct control of door lock.– Power Fail Safe / Power Fail Secure.
• Products to satisfy increased security needs with multiple user credential and vandal resistant options.
Standalone Controller Range
SSA-S1000
SSA-S1000V
SSA-S2000
SSA-S2000V
SSA-S3010/3020/
3040
SSA-S3011/3021/
3041
SSA-S2100
SSA-S2101
Standalone Controller – SSA-S1000 / S1000VProximity Access Controller
• Cost Effective Single Door Control• Slim Aesthetic Design• Ideal Small Business Application• Vandal Resistant Option
• Features– Entry Level Access Control– Standalone (no application software required)– Up to 512 users– Power Fail Safe or Fail Secure lock type– Shadow Cards
• Vandal Resistant (V) Model– Weatherproof and Dustproof (IP68)
Technical Data Link Connection Diagram Link Setup Data Link
Standalone Controller – SSA-S2000 / S2000VProximity and PIN Access Controller
• Cost Effective Duel Technology Single Door Control• Ideal Small Business Application• Vandal Resistant Option• Second (Exit) Reader Option
• Features– Proximity + PIN (options; prox only / PIN only)– Standalone (no application software required)– Up to 512 users– 5 x Inputs, 4 x Output - programmable– Duress Function– Power Fail Safe or Fail Secure lock type
• Vandal Resistant (V) Model– Weatherproof and Dustproof (IP66)
Technical Data Link Connection Diagram Link Setup Data Link
Standalone Controller – SSA-S2100 / S2101Proximity / Smart Card & PIN, Time and Attendance Access Controller
• High Security Applications• Time and Attendance Management• Standalone + Networked Windows Reporting Application / Admin• Second Reader Connection
• Features– Up to 20,000 Users and 20,000 Event Buffer– All combinations of Proximity Card, PIN and Password– 4 x Inputs, 4 x Output – programmable + time schedule– Arm / Disarm function and interface with Intruder Alarm– Time Schedules– Two Man Operation Mode– Duress Function– Power Fail Safe or Fail Secure lock type– Controller or Networked Software Administration
Technical Data Link Connection Diagram Link
Standalone Controller – SSA-S3010 / S3011 SeriesFinger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller
• Triple User Credential, including Biometric.• High Security Applications• Time and Attendance Management• Standalone + Networked Windows Reporting Application / Admin• Second Reader Connection
• Features– Up to 4000 Finger Print Users– All combinations of Finger Print Proximity Card, PIN and Password– 4 x Inputs, 4 x Output – programmable + time schedule– Arm / Disarm function and interface with Intruder Alarm– Time Schedules– Two Man Operation Mode– Duress Function– Power Fail Safe or Fail Secure lock type– Controller or Networked Software Administration
Technical Data Link Connection Diagram Link
Standalone Part Codes
AccessControl
S S A - S □ □ □ □
Samsung
Category
S: Standalone
Type
1 : Card Only
2 : Card & PIN / Card & Finger Print
3: Card, PIN and Fingerprint
System
Format
0 : Samsung 125KHz
1 : Mifare 13.56MHz
3 : EM 125KHz
Fingerprint Users
0 : No Fingerprint
1 : 1,000 Fingerprints
2 : 2,000 Fingerprints
4 : 4,000 Fingerprints
Security Level
1: Special
Standalone SummaryModel Key Feature Application
SSA-S1000 Samsung 125KHz Proximity / 512 Users. Cost effective, entry level Access Controller.
SSA-S1000V Samsung 125KHz Proximity / 512 Users. Vandal resistant.
Cost effective, entry level Access Controller for higher physical risk areas.
SSA-S2000 Duel credential proximity and PIN / 512 users.
Higher security areas requiring duel authentication.
SSA-S2000V Duel credential proximity and PIN / 512 users. Vandal resistant.
Higher security areas requiring duel authentication with high physical risk to the controller.
SSA-S2100 Series Proximity / Smart Card + PIN, Time and Attendance. 20,000 users. Optional networked administration software.
High level security applications requiring Time and Attendance, Anti Pass Back and Arm / Disarm functions.
SSA-S3010 Series Finger Print Recognition + Proximity / Smart Card + PIN, Time and Attendance. 20,000 users. Optional networked administration software.
Top level security applications requiring Biometric recognition, Time and Attendance, Anti Pass Back and Arm / Disarm functions.
All models Controlled Access Lock Control No software necessary
Standalone controlled door access with lock control.
Standalone Controller – Questions?
Access Control Intelligent Controllers
• Intelligent door controllers provide distributed processing for the interface of access control readers, keypads, inputs and outputs back to a Host Computer.
Intelligent Controllers - Distributed Processing
• Distributed processing allows each intelligent controller to operate independent of the host computer with most of the decisions made at the controller.
• This provides instant response for door control and alarm sensing while leaving the host computer with more processing power for actions like alarm response and database updates.
Intelligent ControllersState-of-the-art Controllers at affordable prices
• Intelligent control of 1,2,3 or 4 Doors
• Communication: TCP/IP, RS232, RS485 / RS422
• Data Continuity after power failure
• Programmable Inputs / Outputs• Up to 50,000 users• Up to 50,000 event buffer• Wiegand compatible readers
Intelligent ControllersState-of-the-art Controllers at affordable prices
Single Door Controller• Small to Medium Business• Safe non-volatile Flash Data
Memory - for business continuity• Duress Mode Function• Site Arm / Disarm Function• Single door controller• Up to 50,000 users / 50,000
event buffer• Versatile 5 input / 4 output• Select TCP/IP, RS232, RS285 or
RS422 communication
Four Door Controller• Medium to Large Business• Safe non-volatile Flash Data
Memory - for business continuity• Duress Mode Function• Site Arm / Disarm Function• Up to four doors controlled• Up to 50,000 users / 29,500
event buffer• Versatile 15 input / 15 output• Select TCP/IP, RS232, RS285 or
RS422 communicationLink to: Installation Network Configuration Serial Communication
Four Door: Reader Connection Lock Connection Single Door: Reader Connection Input Connection Lock Connection
Intelligent Controller – Questions?
Link to: Installation Network Configuration Serial Communication Four Door: Reader Connection Lock Connection
Single Door: Reader Connection Input Connection Lock Connection
ReadersComprehensive range of readers to satisfy challenging security environments
ReadersComprehensive range of readers to satisfy challenging security environments
• Samsung have developed a range of highly aesthetic readers, which transmit user credentials to the Intelligent Controllers.
• Reader variations include Slim Line, Vandal Resistant, PIN Number and Biometric Fingerprint with a range of card technologies.
Readers – R1000 / R1100Comprehensive range of readers to satisfy challenging security environments
• Elegant looking proximity / smart card / EM reader
• Read Range of 10cm• Both units use the same weatherproof
(IP66)epoxy moulding, so are interchangeable depending on the wall condition or aesthetic preference
• Can be installed on metal door frame or on a wall
• Wiegand output
Link to Technical Specification Link to Wiring Diagram
Readers – R1000V / R1100VComprehensive range of readers to satisfy challenging security environments
• Elegant looking proximity / smart card / EM reader which can be mounted on a metal door frame or on a wall.
• Vandal resistant with a high level of weatherproofing (IP68) for challenging environmental conditions
• Wiegand output
Link to Technical Specification Link to Wiring Diagram
Readers – R2000 / R2000VComprehensive range of readers to satisfy challenging security environments
• Elegant looking proximity / smart card / EM reader with back-lit keypad for PIN entry in dark conditions.
• Can be mounted on metal door frame or wall.
• Vandal option is IP68 and features the capacitive touch sensitive keypad
Link to Technical Specification 2000 Link to Wiring Diagram 2000Link to Technical Specification 2000V Link to Wiring Diagram 2000V
Readers – R2010 / R2011Comprehensive range of readers to satisfy challenging security environments
• Fingerprint recognition and proximity / smart card reader for high security applications
• Auto touch sensor for fingerprint only recognition.
• Operating mode selectable by individual ID (RF Only, fingerprint only, RF + fingerprint)
Link to Technical Specification Link to Wiring Diagram
AccessCon-trol
S S A - R □ □ □ □
Sam-sung
Category
R: Reader
Type
1 : Card Only
2 : Card & PIN / Card & Finger Print
Sys-tem
Format
0 : Samsung 125KHz
1 : Mifare 13.56MHz
3 : EM 125KHz
Fingerprint Users
0 : No Fingerprint
1 : 1,000 Fingerprints
2 : 2,000 Fingerprints
4 : 4,000 Fingerprints
Version
0 ~ 9
Reader Product Codes
Reader – Questions?Comprehensive range of readers to satisfy challenging security environments
SoftwareSamsung Access Management Software
SAMS Basic and SAMS Pro (Video Integration) have a free licence which has full functionality and includes the database engine (SQL Server 2005 Express)
up to the level of 20 doors OR 100 users.
SoftwareSamsung Access Management Software
• SAMS is a programmable, integrated, computer based security system software package that provides access control, alarm point monitoring, access control administration and monitoring to the rest of the hardware system.
• Windows based Server and Client, SAMS is menu driven and easy to use.
Software – SAMS Basic and Basic LiteSamsung Access Management Software
• Scalable access management software built on an SQL Server 2005.
• Dual Monitor support• Integrated Monitoring with site map• Easy In/Output control and
monitoring with Door, Sensor, Alarm Icon on the site map
• Server (SAMS Basic)/ Client (Basic Lite) network configuration
Software Architecture
System Configuration 1
System Configuration 2
Software – SAMS Pro and Pro LiteSamsung Access Management Software
• Video Integration, Command and Control maps.
• Scalable access management software built on an SQL Server 2005.
• Dual Monitor support• Integrated Monitoring with site map• Easy In/Output control and
monitoring with Door, Sensor, Alarm Icon on the site map
• Server (SAMS Pro)/ Client (Pro Lite) network configuration
Software Architecture
System Configuration 1
System Configuration 2
Software – Questions?Samsung Access Management Software
Basic / Basic Lite Pro / Pro Lite
Software Architecture
System Configuration 1
System Configuration 2
Software Architecture
System Configuration 1
System Configuration 2
Appendix / Technical Data• SSA-S1000(V) - Connection Data / Setup
Data / Technical Data• SSA-S2000(V) – Connection Data / Panel
Description / Card Registration / Setup / Technical Data
• SSA-S21XX / S30XX – Panel Description / Basic Installation / Network Diagram / Connection Data / Technical Data
• SSA-P4XX / P1XX – Intelligent Controller / Installation / Network Configuration / Serial Communications / SSA-P4XX Reader + RTE Connection / SSA-P4XX Lock Connection / SSA-P1XX Reader Connection / SSA-P1XX Input Connection / SSA-P1XX Lock Connection 1 Door
• Reader SSA-R1000 + R1100 / Connection Data / Technical Data
• Reader SSA-R1000V + R1100V / Connection Data / Technical Data
• Reader SSA-R2000 / Connection Data / Technical Data
• Reader SSA-R2000V / Connection Data / Technical Data
• Reader SSA-R2010 / 3010 Series / Connection Data / Technical Data
• Software – Basic / Architecture / System Configuration
• Software – Pro / Architecture / System Configuration
Exit Button
DC 12V(+) Power
Door Contact
Device Wiring
PowerConnect +12V of power supply to Red wire.
Connect GND of power supply to Black wire.
Door Sensor
Connect COM terminal of door sensor to Blue wire of door sensor input.
Connect NO terminal of door sensor to GND of power supply.
Exit But-ton
Connect Green wire of exit button input to one wire between wires of exit button.
Connect GND wire of power supply to the other wire.
Standalone Controller – SSA-S1000 / S1000V – Connection Data
Proximity Access Controller
BACK
Standalone Controller – SSA-S1000 / S1000V – Connection Data
Proximity Access Controller
• Door Lock
• Alarm Device
• DC 12V(+) Power
Device Wiring
PowerConnect +12V of power supply to Red wire.
Connect GND of power supply to Black wire.
Door LockConnect (+) wire of door lock to +12V wire of power supply.
Connect (-) wire of door lock to white wire of reader module.
AlarmConnect (+) wire of Alarm to +12V wire of power supply.
Connect (-) wire of Alarm to purple wire of reader module.
Lock Type Select
In a power fail safe, connect GND wire of power supply to Yel-low wire of door lock type input.
In a power fail secure, put a floating state on Yellow wire of door lock type input.
BACK
Step 1
1) Turn the power off2) Short White & Green & Yellow wire
Step 2
1) Turn the power on2) All red led will be turned on and off twice with buzzer3) Turn the power off
Step 3
1) Disconnect White & Green & Yellow wire2) Turn power ON3) Present the card that you wish to use as master card4) Master card has been registered
SSA-S1000 / S1000V Standalone ControllerStandalone Controller – SSA-S1000 / S1000V – Setup Data
Proximity Access Controller
BACK
Standalone Controller – SSA-S1000 / S1000V – Technical DataProximity Access Controller
BACK
DC +12V(Red)
GND (Black )
• Power
• Exit Button
Yellow with Red stripe
Door Contact Connection
Green
COM NC NO
COM
NO
GND (Black )
PIR Sensor
IN#1(Orange)
IN#2(Green with White stripe)
IN#3(Brown)
GND(Black )
• PIR Sensor
Auxiliary Input #1~#3
SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Connection Data
Proximity and PIN Access Controller
BACK
NO(Blue with White stripe)
NC(White with Red stripe)
NO (Purple)
NC(Purple with White stripe)COM (White)
X
Alarm-
+
Alarm Connection
• Door Lock
GND (Black )
DC+12V(Red ) DC+12V Power
-
+POWER FAIL SAFE
POWER FAIL SECURE
DC+12V(Red )
GND (Black )
• Exit Reader
GND (Black )
DC+12V(Red )
DATA0(Pink )
DATA1(Cyan )
DATA0(Pink )
* Connection of POWER FAIL SAFE: Door Lock
* Connection of POWER FAIL SECURE: Door Lock
COM(Gray with Red stripe)
DATA1(Cyan )
SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Connection Data
Proximity and PIN Access Controller
BACK
• When the Main Unit operates in Selection Mode, LED is flashing.
• When a registered Card (or PIN) is read or exit button is pressed, LED will be on for 3 seconds along with the "do-mi-sol-do" melody, and Lock will be opened.• When an unregistered Card (or PIN) is read, LED will be on for 2 seconds along with the "sol-do-sol-do" melody.
•When the Main Unit operates in normal mode LED is flashing every second.
Keypad
LED Indicator
SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Front Panel DescriptionProximity and PIN Access Controller
BACK
Step 1
1) Turn the power off2) Short Green & Orange with white stripe wires3) Turn the power on4) 3 color LED blinking with beep sound indicates the success of initial-
ization.
Step 2
1) Disconnect Orange & Orange with white stripe wires2) 3 color LED keep blinking (Initial Mode)
Step 3
1) Select the Operation Mode - Card Only (0,1,ENT) - Card + PIN (0,2,ENT) - PIN Only (0,3,ENT) - Card / PIN Combination (0,5,ENT)2) Present the card that you wish to use as master card3) Register Users or Present Master card again to exit registration ModeMaster Card Master CardUser Access Cards or PINs
SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Master Card Registration
Proximity and PIN Access Controller
BACK
Initial Setup is required upon the first time the unit is powered-up in order to operate the unit properly.1) Registration of RF Cards for RF CARD ONLY MODE2) Registration of RF Cards with PINs for RF CARD + PIN MODE3) Registration of PIN ONLY MODE4) Registration of RF/PIN Combination MODE
1) Registration of RF Cards for RF CARD ONLY MODE 2) Registration of RF Cards with PINs for RF CARD + PIN MODE(1) Apply 12VDC to the unit.All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~).(2) Press ‘0’,’1’,’ENT’ from the keypad. (RF CARD ONLY MODE )(3) Present RF Cards as follow to register Master Card and User Access Cards.
(1) Apply 12VDC to the unit.All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~).(2) Press ‘0’,’2’,’ENT’ from the keypad. (RF CARD + PIN MODE )(3) Present RF Cards as follow to register Master Card and User Access Cards + 4~6 digit Personal Identification Number (PIN) for each User Access Card.
(4) The first card read becomes the Master Card and the following RF Cards are registered as User Access Cards. Once all User Access Cards have been reg-istered, present the Master Card again to complete the registration. (Please keep the Master Card in a secure location for future changes.)(5) Now, the Main Unit is entered into the normal operation mode with fac-tory defaulted settings.
(4) The first card read becomes the Master Card and the following RF Cards + PINs are registered as User Access Cards with assigned PINs. Once all User Ac-cess Cards and PINs have been registered, present the Master Card again to complete the registration. (Please keep the Master Card in a secure location for future changes.)(5) Now, the Main Unit is entered into the normal operation mode with fac-tory defaulted settings.
Master Card User Access Cards Master Card again to end task Master Card User Access Cards + PINs Master Card again to end task
SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Initial Setup
Proximity and PIN Access Controller
BACK
3) Registration of PIN ONLY MODE 4) Registration of RF/PIN Combination MODE(1) Apply 12VDC to the unit.All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~).(2) Press ‘0’,’3’,’ENT’ from the keypad. (PIN ONLY MODE)(3) Enter 4~6 digit PIN+’ENT’ to register Configuration PIN then 4~6 digit PIN+ ‘ENT’ to register for each subsequent User Access PIN at a time and then enter the 4~6 digit PIN+’ENT’ (Configuration PIN) to complete the registration.
(1) Apply 12V DC to the unit. All 3 LEDs will be flashing with a power-up melody. (2) Press ‘0’,’5’,’ENT’ from the keypad. (RF/PIN Combination Mode) (3) Present Master Card to register Master Card to the unit.
(4) The first 4~6 digit PIN becomes the Configuration PIN and the subsequent 4~6 digit PINs are registered as User Access PINs. Once all User Access PINs have been registered, enter the Configuration PIN again to complete the regis-tration. (Please store the Configuration PIN for future changes.)(5) Now, the Main Unit is entered into the normal operation mode with fac-tory defaulted settings.
(4) Present RF Card or enter 4~6 digit PIN number to register user access card or PIN.(5) Present Master Card to complete the registration
Please refer to Summary Table of Commands for configuring functions
Caution
Configuration PIN
User Access PIN
Configuration PIN again to complete the registration.
Master Card Master Card
User Access Cards or PINs
SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Initial Setup
Proximity and PIN Access Controller
BACK
No Command Action/Change setting values No Command Action/Change setting values1 11 Add User Access Cards (RF CARD ONLY MODE) 31 48 Disable Unlock followed by Door Contact
2 12 Add User Access Cards and PIN (RF CARD + PIN MODE) 32 51 Disable Melody sound (turning off both the melody & key press audio feedback)
3 13 Add User Access PIN numbers (PIN ONLY MODE) 33 52 Enable Melody sound4 14 Delete User Access Cards (or PIN) 34 60 Change keypad lock-out time when Try-Out error detected5 15 Add User Access Card/PIN (RF/PIN Combination Mode) 35 61 Set Aux Input #1 Detection from ‘L’ to ‘H’
6 21 Change Door open time when User Access Card (or PIN) is granted 36 62 Set Aux Input #1 Detection from ‘H’ to ‘L’
7 22 Change Alarm time when User Access Card (or PIN) is denied 37 63 Set Aux Input #2 Detection from ‘L’ to ‘H’
8 23 Change Alarm time when Try-Out error detected 38 64 Set Aux Input #2 Detection from ‘H’ to ‘L’9 24 Change Alarm time when Door-Contact error detected 39 65 Set Aux Input #3 Detection from ‘L’ to ‘H’
10 25 Change Alarm time when Aux Input #1 detected 40 66 Set Aux Input #3 Detection from ‘H’ to ‘L’ 11 26 Change Alarm time when Aux Input #2 detected 41 67 Set Exit Button Input Detection from ‘L’ to ‘H’12 27 Change Alarm time when Aux Input #3 detected 42 68 Set Exit Button Input Detection from ‘H’ to ‘L’13 28 reserved 43 69 Set Door-Contact sensor Input Detection from ‘L’ to ‘H’ 14 29 Register 2 digits Duress Alarm password 44 70 Set Door-Contact sensor Input Detection from ‘H’ to ‘L’15 30 Change Alarm time when Duress Alarm detected 45 71 Activate TTL output to ‘H’16 31 Test Door open time set by command "21" 46 72 Activate TTL output to ‘L’17 32 Test Alarm time set by command "22" 47 73 Enable Keypad Input To Enter ID Number18 33 Test Alarm time set by command "23" 48 74 Disable Keypad Input To Enter ID Number19 34 Test Alarm time set by command "24" 49 77 Enable Chime Bell Output20 35 Test Alarm time set by command "25" 50 78 Disable Chime Bell Output21 36 Test Alarm time set by command "26" 51 80 Set delay time to activate SECURE MODE22 37 Test Alarm time set by command "27" 52 81 Set Door Open time-out for Door-Contact sensor23 39 Change Chime Bell activating time 53 82 Set number of times of Try-Out24 41 Open door unconditionally 54 83 Set input key press time-out time 25 42 Close door unconditionally 55 84 Set Tamper Alarm output port26 43 Enable QUICK ACCESS MODE 56 88 Enable Tamper Alarm27 44 Disable QUICK ACCESS MODE 57 89 Disable Tamper Alarm28 45 Enable Toggle Mode for Lock control 58 99 Re-Initialize and erase all setup data29 46 Disable Toggle Mode for Lock control30 47 Enable Unlock followed by Door Contact
Standalone Controller – SSA-S2000 / S2000V – Initial Setup
BACK
Standalone Controller – SSA-S2000 / S2000V – Technical Data
Proximity and PIN Access Controller
BACK
①②
③④
⑤
①②
③
④
SSA-S30xx Series SSA-S210x Series
LCD Display Keypad
Function keys LED
Indicators
Fingerprint scanner
LCD Display
Keypad
Function keys
LED Indicators
SSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx / S21xx Series – Panel Description
Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller
BACK
SSA-S30xx / SSA-S210x Standalone Controller
Door Contact
Management Software• Dedicated / Integrated
Exit Button
Door Lock
EXIT
Power+12V DCGND
Standalone Controller – SSA-S30xx / S21xx Series – Basic Installation
Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller
BACK
SSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx / S21xx Series – Network Diagram
Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller
BACK
Black -
Red +
Wiegand DATA 0 (Pink wire)Wiegand DATA 1 (Cyan wire)
Door contact
Exit Button
Black -
Red +Power : DC 12V(+)
SSA-S30xx / SSA-S210x Standalone Controller
• Door contact: Yellow with Red stripe wire & GND• Exit Button: Orange wire & GND• 2.2KΩ connection for cut-off checking
• Wiegand DATA 0 : Pink wire• Wiegand DATA 1 : Cyan wire
Standalone Controller – SSA-S30xx / S21xx Series – Connection Data
Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller
BACK
Door Re-lay
COM (Gray with white stripe wire ) NO ( White with Red stripe wire )
NC ( Blue with white strip wire )
Alarm Relay
COM ( White wire ) NO ( Purple ) NC ( Purple with white stripe wire )
Black -
Red +
SSA-S30xx / SSA-S210x Standalone ControllerSSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx / S21xx Series – Connection Data
Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller
BACK
Standalone Controller – SSA-S21XX Series – Technical Data
Proximity / Smart Card & PIN, Time and Attendance Access Controller
BACK
SSA-S30xx / SSA-S210x Standalone ControllerSSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx Series – Technical Data
Fingerprint Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller
BACK
Reader• Card / Keypad / Biometric
Control Panel• RS485 / TCP/IP
Door Contact
EXIT
Management Software• Dedicated / Integrated
Exit Button
Door Lock
PowerAC 90~250V50/60Hz
SSA-P42xx / P40xx / P112x / P102x Control PanelIntelligent ControllersBasic Installation Diagram
BACK
SSA-P42xx / P40xx / P112x / P102x Control PanelIntelligent ControllersNetwork Configuration Diagram
BACK
Cross ConnectConverter to controllerTX(-) ↔ RX(-)TX(+) ↔ RX(+)RX(-) ↔ TX(-)RX(+) ↔ TX(+)
Direct ConnectController to controllerTX(-) ↔ TX(-)TX(+) ↔ TX(+)RX(-) ↔ RX(-)RX(+) ↔ RX(+)
SSA-P42xx / P40xx / P112x / P102x Control PanelIntelligent ControllersSerial Communications
BACK
SSA-P42xx / P40xx Control Panel
• Reader Power sources can be used separately, but GND has to be wired together. In the case of separate wiring , due to voltage level difference, communication error can be happened.
• All reader ports should be wired in the same way.
READER
DATA 0 (Green)
+12V (Red)
DATA 1 (White)
GND (Black)
EXIT
Exit Button
Intelligent Controllers SSA-P4XXConnection Diagram for Reader & Exit Button
BACK
Intelligent Controllers SSA-P4XXConnection Diagram for Door Lock
• Power Fail Secure - Power off Lock - Power on Unlock• Power Fail Safe - Power off Unlock - Power on Lock• Relay Output #1 & #3 are set up for door lock as default value
• In the case of Power off, if door is locked, the lock is called ‘Power Fail Secure Lock’.
Cathode Anode
1N4004 ~ 1N4007
BACK
• Separate power for readers can be also connected, but two power line should be connected to the same ground otherwise communication error may occur due to different level of voltage.
Reader #1
Reader #2
Intelligent Controllers SSA-P1XXConnection Diagram for Reader
BACK
Exit Button
Door Contact
• INPUT #1 is for Exit button and INPUT #2 is for Door Contact.
• #3 ~ #5 is user selectable.
EXIT
Intelligent Controllers SSA-P1XXConnection Diagram for Input
BACK
• According to lock activation mode, there are NO/NC types and wiring should be done accordingly.
• Using reverse diode is recommended to prevent electric surge when lock is activated.
Normal Open
Normal Close
Intelligent Controllers SSA-P1XX Connection Diagram for Door Lock l
BACK
Readers – R1000 / R1100 – Connection Data
BACK
Readers – R100X / R110X – Technical Data
BACK
Readers – R1000V / R1100V – Connection DataComprehensive range of readers to satisfy challenging security environments
BACK
Readers – R1000V / R1100V – Technical Data
BACK
Readers – R2000 – Connection DataComprehensive range of readers to satisfy challenging security environments
BACK
Readers – R2000 – Technical Data
BACK
Readers – R2000V – Connection DataComprehensive range of readers to satisfy challenging security environments
BACK
Readers – R2000V – Technical DataComprehensive range of readers to satisfy challenging security environments
BACK
SSA-R20xx Biometric Reader
• TCP/IP connection is only for the uploading / downloading the fingerprint data.
Readers – R2010 Series – Connection Data
BACK
Readers – R2010 Series – Technical DataComprehensive range of readers to satisfy challenging security environments
BACK
SAMS BasicSAMS Basic Lite
Application &Database
Access Controller(Hardware)
SAMS Basic Communication Server
SSA-P40x/SSA-P102SSA-S30xx/210x/SSA-R20xx
Communication Server
Database Server(Microsoft SQL Server 2005)
Serial Communication
TCP/IP
TCP/IP TCP/IP
TCP/IP
Software - Basic - ArchitectureSamsung Access Management Software
BACK
TCP/IP
TCP/IP or Serial
Loop
Database(MS SQL)
Application(SAMS Basic or
SAMS Basic Lite)
Comm. Server
Support up to10 Application
Support up to 10Comm. Server
Support up to 100 Loop
Support up to 32 Controller (if Serial Loop)
Support up to4 Door (if SSA-P42xx)
With one system(Database), support up to10 (Comm. Server) x 100 (Loop) x 1 (Controller) x 4 Doors =
4,000 Doors
Software – Basic - System ConfigurationSamsung Access Management Software
BACK
Branch Office #2 Branch Office #1
Head OfficeDatabase Server(MS SQL Server)
Serial Communication
SAMS BasicComm. Server
SAMS Basic(SSA-M1000)
SerialCommunication
Internet (Backbone, WAN)
TCP/IP Network (LAN)
TCP/IP Network(LAN)TCP/IP Network(LAN)
SSA-P112 SSA-P112 SSA-P112
SSA-P420T SSA-S3010 SSA-S2100
SAMS Basic Lite(SSA-M1100)
SAMS Basic Lite(SSA-M1100)
SAMS Basic(SSA-M1000)
SAMS Basic Lite(SSA-M1100)
SerialCommunication
SSA-P420
SSA-S3010 SSA-S2100
SSA-P112 SSA-P112
SSA-S3010 SSA-S2100
SAMS Basic Lite(SSA-M1100)
SAMS Basic(SSA-M1000)
SSA-P420
SAMS BasicComm. Server
SAMS BasicComm. Server
Software - BasicSamsung Access Management Software
BACK
SAMS Pro
SAMS Pro LiteApplication &
Database
Access Controller(Hardware)
SAMS Basic Communication Server
SSA-P40x/SSA-P102SSA-S30xx/210x/SSA-R20xx
Communication Server
Database Server(Microsoft SQL Server 2005)
Serial Communication
TCP/IP
TCP/IP TCP/IP
TCP/IP
DVR(SHR, SRD Series)TCP/IP
Software – Pro - ArchitectureSamsung Access Management Software
BACK
TCP/IP
TCP/IP or Serial
Loop
Database(MS SQL)
Application(SAMS Pro or
SAMS Pro Lite)
Comm. Server
Support up to10 Application
Support up to 10Comm. Server
Support up to 100 Loop
Support up to 32 Controller (if Serial Loop)
Support up to4 Door (if SSA-P42xx)
With one system(Database), support up to10 (Comm. Server) x 100 (Loop) x 1 (Controller) x 4 Doors =
4,000 Doors
No limitation withDVR Connection
Up to 8 video channel can be
monitored simultaneously
Software – Pro - ConfigurationSamsung Access Management Software
BACK
Branch Office #2 Branch Office #1
Head Office Database Server(MS SQL Server) SAMS Pro
Comm. ServerSerial
Communication
SAMS Pro(SSA-M2000)
SerialCommunication
Internet (Backbone, WAN)
SSA-P112 SSA-P112 SSA-P112
SSA-P420T SSA-S3010 SSA-S2100
SAMS Pro Lite(SSA-M2100)
SAMS Pro Lite(SSA-M2100)
SAMS Pro(SSA-M2000)
SAMS Pro Lite(SSA-M2100)
SerialCommunication
SSA-P112 SSA-P112
SSA-S3010 SSA-S2100
SSA-P112 SSA-P112
SSA-S3010 SSA-S2100
SAMS Pro Lite(SSA-M2100)
SAMS Pro(SSA-M2000)
SAMS ProComm. Server
TCP/IP Network (LAN)
TCP/IP Network(LAN)
CCTV System
CCTV System
SAMS ProComm. Server
CCTV System
TCP/IP Network(LAN)
Software – Pro - ConfigurationSamsung Access Management Software
BACK
END HERERest not used