samsung air conditioning and heat pump systems Catalogue 2010
Smart Thinking,Simple Living.
Contents
INTRODUCTION04 | Global business network
RAC SYSTEMS: ROOM AIR CONDITIONERS10 | Wall mounted units
CAC SYSTEMS: COMMERCIAL AIR CONDITIONERS26 | Outdoor units28 | Indoor units
FJM SYSTEMS: FREE JOINT MULTI-SPLIT AIR CONDITIONERS62 | Outdoor units68 | Indoor units78 | Capacity combinations
CONTROLS87 | Controls range
KEY 91 | Key to icons
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
PROJECTKathy Heyndels Glyfada
LOCATIONGreece
TYPEShop
4
5
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
5
Global Business Network
Los Angeles
Mexico
Osaka
Delhi
SE Asia
SW Asia
ME AsiaAfrica
Milano
Stuttgart
London
Europe
CIS
ChinaIndia
Shanghai
Malaysia
Thailand
TokyoJapan
SeoulKorea (Suwon)
Korea (Kwangju)
Chicago
Latin America
US
6 Global Operation Centers 7 Design Centers 4 HA R&D Centers10 Global Headquarters
1. Coca Cola2. IBM3. Microsoft
**18. Honda
20. Apple
**29. Sony33. Cannon75. Panasonic
Samsung has overtaken Sony as the world's biggest producer of televisions and its strong
product development has resulted in global leadership in the television segment. Samsung
improved its position from third to the second leading player in mobile phones worldwide. The
philosophy of bringing people the latest technology at a fair price has quickly made it a firm
consumer favourite. New concept shops have been successful in translating to a more expert and
demanding audience by showing the benefits of engaging with the brand.
As a global leader, Samsung will continue to create future with the customers.
6
Every day, all of us need to seek new ways to reduce energy consumption at home and at work. To fulfill customer’s greener way of life,
Samsung continues to manufacture eco-friendly products. Unfortunately, many consumers are unaware of green products and feel there
are not enough options. So now, Samsung created PlanetFirst™ which applies to all of Samsung’s eco-friendly products, partnerships
or internal programs.
PlanetFirstTM is the name that easily identifies eco-friendly products from Samsung. These products join customers' desire of living a green
lifestyle with enjoying the latest in technology. PlanetFirstTM, a unique communication, makes Samsung's commitment, mind-set, and
approach to greener living clear and straightforward. As Samsung continues to work, develop, engineer, and design innovative products
to satisfy customers, PlanetFirstTM also means these technologies, designs, and manufacturing processes are greener. Your choice of
PlanetFirstTM products helps preserve nature and reduce energy use.
Samsung is always striving to find new and better ways to reduce our impact on the environment without sacrificing complete satisfaction
in its products. Samsung started by simply reducing, reusing, and recycling; then by challenging employees to seek out and adopt
extraordinary breakthroughs that make Samsung's processes and products healthier, safer, and less carbon dependent. So help the
cause and start your own journey in being green with PlanetFirstTM.
Samsung eco mark TCO Sweden Blue Angel Germany EPEAT US Eco Mark Korea 2Energy mark Korea Eco Mark Korea Ecoflower EU Energy Star Mark
Samsung Electronics makes an effort to develop environment-friendly products that minimize the negative impacts on the environment
in every aspect of its products, from raw material procurement, production, transportation, usage, and final disposal. Concerns for the
environment are at the core of each product development.
Samsung's environment-friendly technologies and recycling programs have received global approval, receiving well-known awards and
recognitions worldwide.
7
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Samsung's Four Seasons of Hope supports community-based foundations and charities headed by some of this country's favourite
sports legends. Samsung pledges to raise national awareness and funds for these outstanding charities and to identify how others can
also make a difference in the lives of these children and families.
As technology continually evolves, so will your digital lifestyle. When you upgrade your consumer electronics, you will need to recycle your
old products responsibly. That's why we're proud to reaffirm our commitment and responsibility to recycle using the new
Samsung Recycling DirectSM program launched on October 1st, 2008.
8
‘Eco-friendly’ Samsung
Preserves the nature you live in.
Thinking of you and the environment, Samsung plans for the future. Realizing your hopes for a greener,healthier life for you and the generations that follow, Samsung’s environmentally friendly technologies workto make the world a more beautiful place.
Air & WaterConservation
As a leading innovator of environment-
friendly products and technologies,
Samsung products already drastically
reduce the strains on nature's valuable
resources. Samsung uses R-600, a
natural refrigerant, and cyclopentane
insulation in its refrigerators, which do not
promote global warming or add to the
greenhouse effect. Samsung's water-
efficient washing machines also use less
detergent and water without affecting
cleanliness, helping conserve water.
Samsung products are energy
efficient, receiving Energy Grade A+ in
the EU and ENERGY STAR in the U.S.
Samsung washers with ceramic
heaters use less power, which save
you energy, money and time. This
energy-efficient technology protects
you and nature, giving you a greener
lifestyle.
Samsung Electronics is making significant
efforts to save the environment and
complies with the WEEE (Waste
Electrical and Electronic Equipment)
directive by joining or establishing the
recycling schemes for each country.
Use Less, Save More
Global Recycling
Making continuous efforts to stay eco-friendly, Samsung uses R-410A,
all-environmentally-friendly refrigerant, for its air conditioners and
restrains the use of materials with high global warming potential (GWP).
Most Samsung products have received Energy Grade A+ in the EU
and ENERGY STAR in the U.S. These energy-efficient air
conditioners not only save you money, but help conserve the
environment.
Samsung Eco-Friendly Air Conditioner
9
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Galeria deInnovacion2009Samsung attended Europe’s largest air-conditioner exhibition “Climatization”in Madrid, Spain. Samsung air conditioner's beautiful design with innovative features was awarded the“Galeria de Innovacion” The idea behindthis award is to encourage innovation inthe practical application of know-howand technologies in industrial development. Once again, Samsungproves its unsurpassed standards inquality.
As one of the world's oldest and prestigious design competitions, theiF product design award can lookback on a rich and long tradition. Thisseal of fine design quality has stood forqualitatively outstanding design awardsfor over 50 years. Samsung's airconditioner with design innovations haswon the iF product design award forthe year 2009.
Samsung air conditioner continues toreceive worldwide recognition andawards, proving high quality functionsand beauty to value and satisfying customers' requirements.
Organized by Fiera MilanoInternational, the Comfort & DesignAward plays the role of intermediarybetween the Jury and companiesparticipating in the 36th MostraConvegno Expocomfort / Expobagno.The MCE / EXPOBAGNO 2008 aimedto reward the best product thatshows a high level of environmentalquality, providing a complete overviewof the sector along the lines of"Comfort & Living Technology". And Samsung air conditioner won the prize conferring a valid and professional recognition on the bestproducts in the ceremony .
iF ProductDesign Award2009
Comfort &Design 2008
Received Certifications and Awards
62
FJM AIR CONDITIONERS
FJM 2010 Line-Up
2010 Line-Up
Once again we are introducing our product line-up with Samsung’s innovative technologyequipped to each and every one of them. Take a look at Samsung’s 2010 products madeto satisfy you.
Powerful new line-up
OUTDOOR UNITSMH040FXEA2C MH050FXEA2C MH060FXEA3B MH070FXEA4B MH080FXEA4B
4.0kW
2 Unit
5.0kW
2 Unit
6.0kW
3 Unit
7.0kW
4 Unit
8.0kW
4 Unit
INDOOR UNITS2.0/2.3 kW 2.6 kW 3.5 kW 5.2 kWType Capacity
MB(White)
MB(Black)
Vivace
Neo Forte
Console
Slim 1Way cassette
Mini 4Way cassette
Slim Duct
MSP Duct
Crystal
(3.0kW)
63
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Compact but powerful outdoor unit
01 Outdoor Units
For the residential place relatively large for a single air
conditioning system and the commercial place with
limited space for large outdoor units, Samsung free joint
multi air conditioner is the perfect fit for your needs.
Samsung’s free joint multi outdoor unit will make your life
easier with its compact size and surprise you with its
powerful capacity, which can cover the entire space of
your house or business.
PROJECTGyong Plaza
LOCATIONGyong yos, Hungary
TYPEShopping-Mall
64
FJM AIR CONDITIONERS
Feature4 in 1 SystemThe Advantage of Samsung’s FJM is that a single outdoor unit supports up to 4 indoorunits. Use your backyard more wisely with much more space available created by lessnumber of outdoor units.
BLDC(Twin Rotary) Compressor
Highly Efficient BLDC Motor
- Creative motor core design- High density neodymium magnet- Concentrated type stator
Extremely Low Vibration
- Twin eccentric cams- 2 balance weights
Highly Stable Moving Parts
- Optimal material matching rollers andvanes
- Highly robust bearings- Coated vane- Coated shaft
Wide Operation Range ofOutdoor Temperature BLDC Compressor is applied on all FJM
outdoor models.
High Performance
65
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
66
FJM AIR CONDITIONERS
Feature
TBR Sine Wave CompressorNew FJM models have applied the twin BLDCcompressor with highly stable moving parts, whichreduces torque variation by 70% compared to theconventional single BLDC compressor.
Conventional New
Sine Wave ControllerAll the FJM models have adopted this newly developed Sine Wave Controller. No ripple in the current wave makes soft acoustic quality and reduces noise.
Current Wave
Torque Ripple
Current Wave
Torque Ripple
Current Wave
Torque Ripple
Current Wave
Torque Ripple
Conventional Square Wave Controller New Sine Wave Controller
Felt StructureNew felt has been selected for more quiet compressor operation. Double layered felt structures and the felt cover on the top of thecompressor absorb and minimize the noise.
67
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Specification
Max number of connectable indoor units
Performance
Sound
Power
Power Supply
Mode
Compressor
Refrigerant
Fan
Set Size
Piping
Connections
Operating
Temp. Range
MH040FXEA2C
Horse Power
Capacity
Sound Pressure (Cooling/Heating) *3)
Running
Current
Nominal Input
Circuit Breaker(MCCB/ELB)
Type
Piston Displacement
Output
Lubricant
Type
Factory Charging
Type
Output
Airflow Rate
Net Weight
Shipping Weight
Net Dimensions(WxHxD)
Shipping Dimensions(WxDxH)
Liquid(Flare)
Gas(Flare)
Installation
Limitation
Cooling
Heating
-
HP
kW
Btu/h
kW
Btu/h
dB(A)
A
A
W
W
A
Ø/V/Hz
-
-
cc/Rev
kW
-
cc
-
kg
-
W
m3/min
kg
kg
mm
mm
Ø,mm
Ø,mm
m
m
ºC
ºC
Cooling *1)
Heating *2)
Cooling
Heating
Cooling
Heating
Type
Charging
Max. Length
Max. Height
2
1.5
3.9
13,307
4.4
15,013
48/49
5.2
5.1
1,140
1,120
9.0
1/220~240/50
Heat Pump
TWIN BLDC INV.
19.52
5.86
POE
700
R410A
1.3
Propeller
25
25.4
41
44
790X548X285
926X630X382
1/4X2
3/8X2
30
15
-5~43
-15~24
MH050FXEA2C
2
1.8
5.0
17,060
5.7
19,448
49/51
6.1
6.4
1,330
1,400
13.5
1/220~240/50
Heat Pump
TWIN BLDC INV.
19.52
5.86
POE
700
R410A
2.0
Propeller
40
32.9
53
57
880X638X310
1,023X695X413
1/4X2
3/8X1+1/2X1
30
15
-5~43
-15~24
MH060FXEA3B
3
2.0
5.9
20,131
6.3
21,496
50/51
7.3
6.4
1,600
1,400
14.5
1/220~240/50
Heat Pump
TWIN BLDC INV.
19.52
5.86
POE
700
R410A
2.2
Propeller
130
41
59
63
880X798X310
1,023X889X413
1/4X3
3/8X2+1/2X1
45
15
-5~43
-15~24
MH070FXEA4B
4
2.5
7.0
23,884
8.6
29,343
51/52
8.7
9.2
1,900
2,000
16.6
1/220~240/50
Heat Pump
TWIN BLDC INV.
25.18
7.77
POE
700
R410A
2.8
Propeller
130
44.8
65
70
880X798X310
1,023X889X413
1/4X4
3/8X2+1/2X2
70
15
-5~43
-15~24
MH080FXEA4B
4
3.0
8.0
27,296
9.3
31,732
52/52
10.5
10.1
2,300
2,200
16.6
1/220~240/50
Heat Pump
TWIN BLDC INV.
25.18
7.77
POE
700
R410A
2.8
Propeller
130
45.4
65
70
880X798X310
1,023X889X413
1/4X4
3/8X2+1/2X2
70
15
-5~43
-15~24
Notes*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
Model
Variety of indoor units
02 Indoor Units
There are various types of indoor units for
Samsung’s free joint multi air conditioning system.
With the outdoor unit that supports up to 4 indoor
units, you can choose from wall-mounted,
cassette, duct and console type indoor units.
Mix and match indoor units to satisfy your air
conditioning needs.
PROJECTKioupia
LOCATIONAthens, Greece
TYPERestaurant
68
FJM AIR CONDITIONERS
MB
Performance
SoundPower
Power SupplyModePiping
Set Size
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)
Model
kWBtu/hkWBtu/hdB(A)-m3/minAWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm
MH026FBEA (White)MH026FBES (Black)
MH035FBEA (White)MH035FBES (Black)
MH052FBEA (White)
3.511,942
3.812,96635/21
Cross Flow Fan9.16/9.460.19/0.19
35/351/220~240/50
Heat Pump6.359.52 ID 1810.2 11.5
900X304X185963X349X247
5.217,742
5.619,10740/30
Cross Flow Fan14.98/14.49
0.3/0.350/50
1/220~240/50Heat Pump
6.3512.70 ID 1813.016.0
1,100X307X2251,157X381X292
2.68,8712.9
9,89531/20
Cross Flow Fan8.14/8.230.18/0.18
30/301/220~240/50
Heat Pump6.359.52 ID 1810.2 11.5
900X304X185963X349X247
TypeAirflow Rate(Cool/Heat)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Specification
Auto Roof Shutter (Dust Free)This unique air conditioner automatically seals off to prevent dirt infiltration when not in operation.
DNA FilterIt is a new technology that screens selectively for only toxic agents.This enables a smarter and effective air management compared toother filters.
(Micro Plasma Ionizer)
The world's first technology that generates active hydrogen atomstogether with oxygen ions to improve your Indoor Air Quality. It protects you from harmful particles and viruses existing in the air.
Good’sleep IIInnovative technology developed to control the air temperature duringyour sleep maintains the optimum skin temperature to let you enjoy a comfortable sleep as well as a refreshed wake up.
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
69
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Vivace
Performance
SoundPower
Power SupplyModePiping
Set Size
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)
Model
kWBtu/hkWBtu/hdB(A)-m3/minAWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm
TypeAirflow Rate(Cool/Heat)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Specification
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
Good’sleep IIInnovative technology developed to control the air temperature duringyour sleep maintains the optimum skin temperature to let you enjoy a comfortable sleep as well as a refreshed wake up.
(Micro Plasma Ionizer)
The world's first technology that generates active hydrogen atomstogether with oxygen ions to improve your Indoor Air Quality. It protects you from harmful particles and viruses existing in the air.
Slim SolutionCompact size and light weight
Mirror DesignAdd chic and graceful image
MH020FVEA
26,8242.2
7,50631/21
Cross Flow Fan7.5/8.1
0.18/0.1830/30
1/220~240/50Heat Pump
6.359.52 ID 188.5 11.5
825X285X189900X349X252
MH026FVEA
2.68,8712.9
9,89531/21
Cross Flow Fan8.5/8.3
0.18/0.1830/30
1/220~240/50Heat Pump
6.359.52 ID 188.5 11.5
825X285X189900X349X252
MH035FVEA
3.511,942
3.812,96635/21
Cross Flow Fan10/10.4
0.19/0.1935/35
1/220~240/50Heat Pump
6.359.52 ID 188.5 11.5
825X285X189900X349X252
MH052FVEA
5.217,742
5.619,10740/30
Cross Flow Fan14.8/14.80.3/0.350/50
1/220~240/50Heat Pump
6.3512.70 ID 1812.0 15.0
1,065X298X2141,137X377X299
70
FJM AIR CONDITIONERS
Crystal
Performance
SoundPower
Power SupplyModePiping
Set Size
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)
Model
kWBtu/hkWBtu/hdB(A)-m3/minAWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm
MH026FAEA MH035FAEA MH052FAEA
3.511,942
3.812,96635/21
Cross Flow Fan9.8/10.00.19/0.19
35/351/220~240/50
Heat Pump6.359.52 ID 189.0 11.0
820X286X190892X355X263
5.217,742
5.619,10740/30
Cross Flow Fan14.2/14.60.3/0.350/50
1/220~240/50Heat Pump
6.3512.70 ID 1813.016.0
1,099X315X2171,137X377X299
2.68,8712.9
9,89531/21
Cross Flow Fan9.1/9.3
0.18/0.1830/30
1/220~240/50Heat Pump
6.359.52 ID 189.0 11.0
820X286X190892X355X263
TypeAirflow Rate(Cool/Heat)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Specification
Catechin FilterCatechin, extracted from green tea, is contained in the filter anddeactivates captured bacteria and unpleasant odours.
(Micro Plasma Ionizer)
The world's first technology that generates active hydrogen atomstogether with oxygen ions to improve your Indoor Air Quality. It protects you from harmful particles and viruses existing in the air.
Good’sleep IIInnovative technology developed to control the air temperature duringyour sleep maintains the optimum skin temperature to let you enjoy a comfortable sleep as well as a refreshed wake up.
Filter Cleaning IndicatorAlways know when to clean the filter. TheFilter Clean Indicator automatically alertsyou when the filter needs to be cleanedwith its illuminating blue light, usually afterabout 500 hours of use. Now, you can
always keep your air conditioner clean. Lowers energy consumption up to50% and reduces the vibration to bring peace into your life.
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
MH020FAEA
26,824 2.2
7,506 31/21
Cross Flow Fan7.9/8.2
0.18/0.1830/30
1/220~240/50Heat Pump
6.359.52 ID 189.0 11.0
820X286X190892X355X263
71
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Neo Forte
Performance
SoundPower
Power SupplyModePiping
Set Size
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)
Model
kWBtu/hkWBtu/hdB(A)-m3/minAWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm
TypeAirflow Rate(Cool/Heat)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Specification
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
MH020FNEA
26,8242.2
7,50632/23
Cross Flow Fan7.73/8
0.18/0.1830/30
1/220~240/50Heat Pump
6.359.52 ID 187.89.4
825X285X189900X349X252
MH026FNEA
2.68,8712.9
9,89532/23
Cross Flow Fan8.31/8.560.18/0.18
30/301/220~240/50
Heat Pump6.359.52 ID 187.89.4
825X285X189900X349X252
MH035FNEA
3.511,942
3.812,96636/23
Cross Flow Fan9.54/9.930.19/0.19
35/351/220~240/50
Heat Pump6.359.52 ID 187.8 9.4
825X285X189900X349X252
MH052FNEA
5.217,742
5.619,10740/30
Cross Flow Fan13.21/14.22
0.3/0.350/50
1/220~240/50Heat Pump
6.3512.70 ID 1813.0 16.0
1,099X315X2171,137X377X299
Good’sleep IIInnovative technology developed to control the air temperature duringyour sleep maintains the optimum skin temperature to let you enjoy a comfortable sleep as well as a refreshed wake up.
Flush Front PanelClean-Cut Front Panel + Silver Accent Line
72
FJM AIR CONDITIONERS
25dB
35dB
30dB
43dB
Low
High
Fan speed Noise level
Quiet Operation Samsung's new blade designdrastically reduces noise levels, soyou can relax in peace and quiet.
Only 135mm thickSamsung introduces the world's slimmest indoor air conditionerunit. Only 135mm thick, the slim 1Way Cassette air conditioner canbe installed practically anywhere.
Ensure that there is sufficient installation space. Allow at least170mm for the installation.
NOTE
Min. 170mm
135m
m
155m
m
Drain pan is included within panel
Slim 1Way Cassette
Performance
SoundPower
Power SupplyModePiping
Set Size
Accessories
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelDrain Pump
Model
kWBtu/hkWBtu/hdB(A)-m3/minAWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm--
TypeAirflow Rate(Cool/Heat)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Specification
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
WIDEWIDEWIDEWIDE
HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
QUICK CONNECTION
OF DRAIN PIPE
HIGH LIFT-UP
DRAIN PUMP
WIDE BLADECEILING SOILING
PREVENTION
MH026FSEA
2.68,8712.9
9,89530/25
Turbo Fan6.2/7.5
0.2345
1/220~240/50Heat Pump
6.359.52
VP20(OD 25,ID 20)10.5 13.5
970x135x4101,164x212x478
PSSMA (Optional)24/750
MH035FSEA
3.511,942
3.812,96632/27
Turbo Fan7.6/8.2
0.2550
1/220~240/50Heat Pump
6.359.52
VP20(OD 25,ID 20)10.513.5
970x135x4101,164x212x478
PSSMA (Optional)24/750
73
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
74
FJM AIR CONDITIONERS
Mini 4Way Cassette
Performance
SoundPower
Power SupplyModePiping
Set Size
Accessories
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelDrain Pump
Model
kWBtu/hkWBtu/hdB(A)-m3/minAWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm--
TypeAirflow Rate(Cool/Heat)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Specification
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
Compact Size The Mini 4Way cassette air conditionercan be installed in one standard ceilingtile (600Wx600H), which can saveinstallation time.
Fan Speed AdjustmentFan speed can be adjusted according toceiling height by adjusting dip switch ofindoor unit’s PCB.
High Energy Efficiency It’s energy efficient. Easy operation coupled with high efficiency provides you with remarkable performance at extremely low cost
3~3.5m
High Ceiling
QUICK CONNECTION
OF DRAIN PIPE
HIGH LIFT-UP
DRAIN PUMPFRESH AIR
INTAKE
MH030FMEA
3.010,200
3.411,60030/25
Turbo Fan10.8/11.70.37/0.37
85/851/220~240/50
Heat Pump6.359.52
VP 25 (OD 32, ID 25)17.0 20.0
575x260x575660x310x635
PMSMA (Optional)Built-in
MH035FMEA
3.511,900
3.812,90034/27
Turbo Fan10.8/11.70.37/0.37
85/851/220~240/50
Heat Pump6.359.52
VP 25 (OD 32, ID 25)17.0 20.0
575x260x575660x310x635
PMSMA (Optional)Built-in
MH052FMEA
5.217,700
5.619,10041/33
Turbo Fan12.1/13.60.52/0.52120/120
1/220~240/50Heat Pump
6.3512.70
VP 25 (OD:32, ID 25)17.0 20.0
575x260x575660x310x635
PMSMA (Optional)Built-in
HIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH QUICKQUICKQUICKQUICK
75
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Slim Duct
Specification
The air inlet can be set up on either the bottom or rear of the unit, so there is more flexibility in installation.
Flexible Installation
Slim DesignOnly 199mm thick, this slimdesign makes installation,maintenance and repaireasy.
199mm
199mm
220mm
225mm
160 180 200 220210 230
Rear side air inlet Bottom side air inlet
Suction Duct Suction Duct
TexTex
Diffuser Diffuser
BACTERIABACTERIABACTERIABACTERIA
ANTI-BACTERIA
FILTER
EASY FILTER
CLEANINGHIGH LIFT-UP
DRAIN PUMP
SMART PRESSURE
CONTROLWIRED REMOTE
CONTROLLER
HIGHHIGHHIGHHIGH
WiredWiredWiredWired
Performance
SoundPower
Power SupplyModePiping
Set Size
Accessories
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)Drain Pump
Model
kWBtu/hkWBtu/hdB(A)-m3/min
mmAq
AWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm-
MH026FEEA MH035FEEA3.5
11,9003.8
12,90032/27
Sirocco Fan9.8/10.3
2/4
0.4/0.480/80
1/220~240/50Heat Pump
6.350.92
VP 25 (OD 32, ID 25)26.0 31.0
900x199x6001,133x333x730MDP-E075SEE
2.68,8002.9
9,80030/25
Sirocco Fan8.6/9.0
2/4
0.4/0.480/80
1/220~240/50Heat Pump
6.359.52
VP 25 (OD 32, ID 25)26.0 31.0
900x199x6001,133x333x730MDP-E075SEE
TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
76
FJM AIR CONDITIONERS
MSP Duct
SpecificationPerformance
SoundPower
Power SupplyModePiping
Set Size
Accessories
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)Drain Pump
Model
kWBtu/hkWBtu/hdB(A)-m3/min
mmAq
AWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm-
TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
The Smart Pressure Control Systemadjusts fan speed according to E.S.P(External Static Pressure), so the airconditioner always gives youconsistent cooling and heatingpower regardless of the surroundingenvironment.
Smart Pressure Control
Easy to Maintain Reduce time and maintenance costs bykeeping parts easily accessible.
Flexible Installation Samsung's MSP Duct air conditioners offer different solutions for anyshape room allowing for specific airflow requirements.
MH052FUEA5.2
17,7425.6
19,10737/33
Sirocco Fan16.3/15.8
4/6
1.04/1.04170/170
1/220~240/50Heat Pump
6.3512.70 ID 26.529.0 34.0
900x260x4801,146x363x584
MDP-M075SGU3
L-shaped area Y-shaped areaAreas far apart
E.S.P Control
Air v
olum
e
Static pressure (mmAq)Minimum Maximum
H
H
M
M
L
L
BACTERIABACTERIABACTERIABACTERIA
ANTI-BACTERIA
FILTER
EASY FILTER
CLEANING
HIGH LIFT-UP
DRAIN PUMP
SMART PRESSURE
CONTROLHIGHHIGHHIGHHIGH
77
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Console
Performance
SoundPower
Power SupplyModePiping
Set Size
Cooling *1)
Heating *2)
Sound Pressure (High/Low) *3)
Fan
Running CurrentPower Input
Connecting Pipe
Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)
Model
kWBtu/hkWBtu/hdB(A)-m3/minAWØ/V/Hz-Ø,mmØ,mmØ,mmkgkgmmmm
TypeAirflow Rate(Cool/Heat)Cooling/HeatingCooling/Heating
Liquid(Flare)Gas(Flare)Drain
Specification
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
Slim Design It can't get any slimmer. This newlyintroduced console type air conditioneris only 199mm thick, the slimmest on themarket. Its slim design easily integrates the unit into your decor.
199mm
Black Display Functional art, the touch screen displayis elegant while it maximizes the convenience of control.
Silent Operation (23dB)The silent, yet powerful and efficientcooling and heating system keeps thingsmore comfortable. Silent mode isavailable in 4 different operating modes:High / Medium / Low / Silence.
(Micro Plasma Ionizer)The world's first technology that generates active hydrogen atomstogether with oxygen ions to improve your Indoor Air Quality. It protects you from harmful particles and viruses existing in the air.
LIGHT WEIGHT
UNIT
SILENT MODEFLEXIBLE PIPE
INSTALLATION
WIRELESS
REMOTE CONTROL
INTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN BACTERIABACTERIABACTERIABACTERIA
LIGHTLIGHTLIGHTLIGHT
Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation WirelessWirelessWirelessWireless
INTERIOR
DESIGN
ANTI-BACTERIA
FILTER
MH026FJEA
2.68,8712.9
9,89528/23
Turbo Fan9.0/10.50.25/0.25
30/301/220~240/50
Heat Pump6.359.52 ID 1815.0 19.0
720x620x199810x710x295
MH035FJEA
3.511,942
3.812,96639/24
Turbo Fan10.5/11.30.29/0.29
35/351/220~240/50
Heat Pump6.359.52 ID 1815.0 19.0
720x620x199810x710x295
MH052FJEA
5.2 17,742
5.619,107 44/25
Turbo Fan11.2/12.60.35/0.35
50/501/220~240/50
Heat Pump6.3512.70 ID 1815.0 19.0
720x620x199 810x710x295
Capacity Combination
03 Capacity Combination
Different installation settings of outdoor / indoor
units can result in a different capacity
combination for each setting.
PROJECTAuditorio Municipal da vila de velas
LOCATIONS. Jorge island (Azores), Portugal
TYPEAuditorium
78
FJM AIR CONDITIONERS
Combination Table
MH040FXEA2CIndoor Unit Combination
Numberof Unit
1 Unit
2 Unit
Cooling Capacity(W) Capacity CurrentPower Consumption
AEER EG
20002600350020002000200026002600
B
---
20002600350026003500
C
--------
D
-------
MAX
%
51%67%90%103%118%141%133%156%
Total Total
20002600350040004600550052006100
A
21002600350019501696141819501662
B
---
19502204248219502238
C
--------
Min.W
12801280130013501500150015001500
Nom.W
21002600350039003900390039003900
Max.Ml
25203120420042004200420042004200
Min.W
400400400420420440440440
Nom.W
540 750 1160 1160 1140 1160 1160 1140
Max.W
630880124012501250125012501250
D
--------
21002600350039003900390039003900
Min.A
2.22.22.22.32.32.42.42.4
Nom.A
2.53.45.35.35.25.35.35.2
Max.A
2.94.05.75.75.75.75.75.7
3.893.473.023.363.423.363.363.42
AABAAAAA
Indoor Unit CombinationNumberof Unit
1 Unit
2 Unit
Heating Capacity(W) Capacity CurrentPower Consumption
ACOP EG
22002900380022002200220029002900
B
---
22002900380029003800
C
--------
D
--------
%
50%66%86%100%116%136%132%152%
Total Total
22002900380044005100600058006700
A
24003100380022001898161322001904
B
---
22002502278722002496
C
--------
Min.W
13001300130015001500150015001500
Nom.W
24003100380044004400440044004400
Max.Ml
29903450437047004700470047004700
Min.W
280280280300300300300300
Nom.W
800 900 1160 1160 1160 1160 1160 1120
Max.W
9101080142013901420149014901490
D
--------
24003100380044004400440044004400
Min.A
1.51.51.51.61.61.61.61.6
Nom.A
3.74.15.35.35.35.35.35.1
Max.A
4.24.96.56.46.56.86.86.8
3.003.443.283.793.793.793.793.93
DBCAAAAA
Cooling
Heating
Note1. Cooling capacity is based on 27°C DB / 19°CWB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°CWB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
79
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
FJM AIR CONDITIONERS
80
Combination Table
MH050FXEA2CIndoor Unit Combination
Numberof Unit
1 Unit
2 Unit
Cooling Capacity(W) Capacity CurrentPower Consumption
AEER EG
200026003500520020002000200020002600260026003500
B
----
20002600350052002600350052003500
C
------------
D
------------
%
40%52%70%104%80%92%110%144%104%122%156%140%
Total Total
200026003500520040004600550072005200610078007000
A
240026003500500020002000181813892500213116672500
B
----
20002600318236112500286933332500
C
------------
Min.W
128012801280130013501350135015001500150015001500
Nom.W
240026003500500040004600500050005000500050005000
Max.Ml
288031204200520048005200540054005400540054005400
Min.W
400400400400420420420440440440440440
Nom.W
7308001090166012451430149013801500150013301500
Max.W
8809601310174014901720178018001780178018001780
D
------------
240026003500500040004600500050005000500050005000
Min.A
1.91.91.91.9222
2.12.12.12.12.1
Nom.A
3.33.75
7.65.76.56.86.36.96.96.16.9
Max.A
44.468
6.87.98.18.28.18.18.28.1
3.293.253.213.013.213.223.363.623.333.333.763.33
AAABAAAAAAAA
Cooling
Heating
Indoor Unit CombinationNumberof Unit
1 Unit
2 Unit
Heating Capacity(W) Capacity CurrentPower Consumption
ACOP EG
220029003800560022002200220022002900290029003800
B
----
22002900380056002900380056003800
C
------------
D
------------
%
39%51%67%98%77%89%105%137%102%118%149%133%
Total Total
220029003800560044005100600078005800670085007600
A
250029003800540022002200209016082850246719452850
B
----
22002900361040922850323337552850
C
------------
Min.W
130013001300145014501450150015001500150015001500
Nom.W
250029003800540044005100570057005700570057005700
Max.Ml
299033404370560047505460630064006300630064006300
Min.W
320320320340350350350350350350350350
Nom.W
88010301300181012201410152014401550148014001470
Max.W
101012901620206013901610195018302060194018301890
D
------------
250029003800540044005100570057005700570057005700
Min.A
1.71.71.71.81.91.91.91.91.91.91.91.9
Nom.A
44.75.98.35.66.57
6.67.16.86.46.7
Max.A
4.65.97.49.46.47.48.98.49.48.98.48.6
2.842.822.922.983.613.623.753.963.683.854.073.88
DDDDAAAAAAAA
Note1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
81
Note1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
Cooling
Heating
MH060FXEA3BIndoor Unit Combination
Numberof Unit
1 Unit
2 Unit
3 Unit
Cooling Capacity(W) Capacity CurrentPower Consumption
AEER EG
2000
2600
3500
5200
2000
2000
2000
2000
2600
2600
2600
3500
3500
2000
2000
2000
2000
2000
2000
2600
2600
B
-
-
-
-
2000
2600
3500
5200
2600
3500
5200
3500
5200
2000
2000
2000
2600
2600
3500
2600
2600
C
-
-
-
-
-
-
-
-
-
-
-
-
-
2000
2600
3500
2600
3500
3500
2600
3500
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
%
34%
44%
59%
88%
68%
78%
93%
122%
88%
103%
132%
119%
147%
102%
112%
127%
122%
137%
153%
132%
147%
Total Total
2000
2600
3500
5200
4000
4600
5500
7200
5200
6100
7800
7000
8700
6000
6600
7500
7200
8100
9000
7800
8700
A
2400
2600
3500
5200
2000
2000
1909
1528
2600
2259
1967
2725
2374
1760
1636
1573
1528
1457
1311
1967
1763
B
-
-
-
-
2000
2600
3341
3972
2600
3041
3933
2725
3526
1760
1636
1573
1986
1894
2294
1967
1763
C
-
-
-
-
-
-
-
-
-
-
-
-
-
1760
2127
2753
1986
2549
2294
1967
2374
Min.W
1280
1280
1280
1300
1300
1300
1300
1380
1300
1300
1380
1300
1380
1500
1500
1500
1500
1500
1500
1500
1500
Nom.W
2400
2600
3500
5200
4000
4600
5250
5500
5200
5300
5900
5450
5900
5280
5400
5900
5500
5900
5900
5900
5900
Max.Ml
2880
3120
4200
5800
4800
5520
6290
6600
5800
6400
6800
6560
6800
6380
6490
6800
6600
6800
6800
6800
6800
Min.W
400
400
400
400
420
420
430
430
420
430
430
430
440
430
430
440
430
440
440
440
440
Nom.W
730
790
1070
1620
1240
1410
1550
1580
1620
1550
1610
1570
1620
1550
1560
1610
1580
1610
1610
1600
1600
Max.W
930
1010
1370
1900
1480
1680
1820
1850
1800
1840
1880
1850
1880
1840
1850
1880
1850
1880
1880
1880
1880
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2400
2600
3500
5200
4000
4600
5250
5500
5200
5300
5900
5450
5900
5280
5400
5900
5500
5900
5900
5900
5900
Min.A
2.2
2.2
2.2
2.2
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.4
2.3
2.3
2.4
2.3
2.4
2.4
2.4
2.4
Nom.A
3.3
3.6
4.9
7.4
5.7
6.5
7.1
7.2
7.4
7.1
7.4
7.2
7.4
7.1
7.1
7.4
7.2
7.4
7.4
7.3
7.3
Max.A
4.3
4.6
6.3
8.7
6.8
7.7
8.3
8.5
8.2
8.4
8.6
8.5
8.6
8.4
8.5
8.6
8.5
8.6
8.6
8.6
8.6
3.29
3.29
3.27
3.21
3.23
3.26
3.39
3.48
3.21
3.42
3.66
3.47
3.64
3.41
3.46
3.66
3.48
3.66
3.66
3.69
3.69
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Indoor Unit CombinationNumberof Unit
1 Unit
2 Unit
3 Unit
Heating Capacity(W) Capacity CurrentPower Consumption
ACOP EG
2200
2900
3800
5600
2200
2200
2200
2200
2900
2900
2900
3800
3800
2200
2200
2200
2200
2200
2200
2900
2900
B
-
-
-
-
2200
2900
3800
5600
2900
3800
5600
3800
5600
2200
2200
2200
2900
2900
3800
2900
2900
C
-
-
-
-
-
-
-
-
-
-
-
-
-
2200
2900
3800
2900
3800
3800
2900
3800
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
%
35%
46%
60%
89%
70%
81%
95%
124%
92%
106%
135%
121%
149%
105%
116%
130%
127%
141%
156%
138%
152%
Total Total
2200
2900
3800
5600
4400
5100
6000
7800
5800
6700
8500
7600
9400
6600
7300
8200
8000
8900
9800
8700
9600
A
2500
2900
3800
5600
2200
2200
2053
1692
2900
2510
2149
2950
2547
1933
1778
1690
1650
1557
1414
2100
1903
B
-
-
-
-
2200
2900
3547
4308
2900
3290
4151
2950
3753
1933
1778
1690
2175
2053
2443
2100
1903
C
-
-
-
-
-
-
-
-
-
-
-
-
-
1933
2344
2920
2175
2690
2443
2100
2494
Min.W
1300
1300
1300
1350
1400
1400
1500
1500
1400
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Nom.W
2500
2900
3800
5600
4400
5100
5600
6000
5800
5800
6300
5900
6300
5800
5900
6300
6000
6300
6300
6300
6300
Max.Ml
2990
3340
4370
6300
5060
5870
6440
6900
6300
6770
7300
6880
7300
6760
6840
7300
6920
7300
7300
7300
7300
Min.W
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
Nom.W
880
1030
1350
1820
1220
1490
1640
1660
1700
1700
1740
1730
1740
1590
1610
1660
1590
1630
1560
1650
1400
Max.W
1110
1270
1660
1920
1510
1830
1860
1860
1910
1900
1830
1860
1830
1840
1840
1830
1840
1830
1830
1830
1830
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2500
2900
3800
5600
4400
5100
5600
6000
5800
5800
6300
5900
6300
5800
5900
6300
6000
6300
6300
6300
6300
Min.A
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
Nom.A
4
4.7
6.2
8.3
5.6
6.8
7.5
7.6
7.8
7.8
8
7.9
8
7.3
7.4
7.6
7.3
7.5
7.1
7.6
6.4
Max.A
5.1
5.8
7.6
8.8
6.9
8.4
8.5
8.5
8.7
8.7
8.4
8.5
8.4
8.4
8.4
8.4
8.4
8.4
8.4
8.4
8.4
2.84
2.82
2.81
3.08
3.61
3.42
3.41
3.61
3.41
3.41
3.62
3.41
3.62
3.65
3.66
3.80
3.77
3.87
4.04
3.82
4.50
D
D
D
D
A
B
B
A
B
B
A
B
A
A
A
A
A
A
A
A
A
82
FJM AIR CONDITIONERS
Combination Table
CoolingMH070FXEA4BIndoor Unit Combination
Numberof Unit
1 Unit
2 Unit
3 Unit
4 Unit
Cooling Capacity(W) Capacity CurrentPower Consumption
AEER EG
2000
2600
3500
5200
2000
2000
2000
2000
2600
2600
2600
3500
3500
5200
2000
2000
2000
2000
2000
2000
2000
2000
2000
2600
2600
2600
2600
3500
2000
2000
2000
2000
2000
2000
2000
2600
B
-
-
-
-
2000
2600
3500
5200
2600
3500
5200
3500
5200
5200
2000
2000
2000
2000
2600
2600
2600
3500
3500
2600
2600
2600
3500
3500
2000
2000
2000
2000
2000
2600
2600
2600
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2000
2600
3500
5200
2600
3500
5200
3500
5200
2600
3500
5200
3500
3500
2000
2000
2000
2600
2600
2600
2600
2600
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2000
2600
3500
2600
3500
2600
3500
2600
%
29%
37%
50%
74%
57%
66%
79%
103%
74%
87%
111%
100%
124%
149%
86%
94%
107%
131%
103%
116%
140%
129%
153%
111%
124%
149%
137%
150%
114%
123%
136%
131%
144%
140%
153%
149%
Total Total
2000
2600
3500
5200
4000
4600
5500
7200
5200
6100
7800
7000
8700
10400
6000
6600
7500
9200
7200
8100
9800
9000
10700
7800
8700
10400
9600
10500
8000
8600
9500
9200
10100
9800
10700
10400
A
2400
2600
3500
5200
2000
2000
2000
1944
2600
2600
2333
3500
2816
3500
2000
2000
1781
1522
1847
1664
1429
1516
1308
2240
2029
1750
1896
2330
1680
1577
1474
1522
1386
1429
1308
1750
B
-
-
-
-
2000
2600
3500
5056
2600
3500
4667
3500
4184
3500
2000
2000
1781
1522
2401
2163
1857
2652
2290
2240
2029
1750
2552
2330
1680
1577
1474
1522
1386
1857
1701
1750
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2000
2600
3118
3957
2401
3119
3714
2652
3120
2240
2732
3121
2552
2330
1680
1577
1474
1978
1802
1857
1701
1750
Min.W
1350
1350
1350
1400
1500
1690
1770
1900
1750
1820
1900
1900
1900
1900
1810
1870
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
Nom.W
2400
2600
3500
5200
4000
4600
5500
7000
5200
6100
7000
7000
7000
7000
6000
6600
6680
7000
6650
6740
7000
6820
7000
6720
6790
7000
7000
6990
6720
6780
7000
7000
7000
7000
7000
7000
3000
3480
4200
6240
4800
5520
6600
8400
6240
7320
8400
8400
8900
8900
7200
7920
8020
8900
7980
8080
8900
8180
8900
8050
8150
8900
8900
8900
8070
8140
8900
8900
8900
8900
8900
8900
Max.Ml
Min.W
380
390
400
420
410
420
430
580
420
440
580
580
580
580
440
440
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
Nom.W
780
840
1130
1520
1240
1430
1710
2180
1660
1880
2130
2120
2110
2000
1800
1830
1835
1850
1830
1840
1880
1850
1930
1840
1850
1880
1880
1900
1850
1880
1900
1880
1900
1900
1930
1900
Max.W
950
1100
1580
2160
1490
1720
2050
2520
2000
2260
2540
2530
2540
2540
2280
2460
2410
2460
2410
2460
2460
2510
2510
2420
2460
2510
2460
2510
2460
2460
2460
2460
2510
2460
2550
2550
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1680
2050
2579
1978
2426
1857
2290
1750
2400
2600
3500
5200
4000
4600
5500
7000
5200
6100
7000
7000
7000
7000
6000
6600
6680
7000
6650
6740
7000
6820
7000
6720
6790
7000
7000
6990
6720
6780
7000
7000
7000
7000
7000
7000
Min.A
1.7
1.8
1.8
1.9
1.9
1.9
2
2.7
1.9
2
2.7
2.7
2.7
2.7
2
2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
Nom.A
3.6
3.8
5.2
7
5.7
6.5
7.8
10
7.6
8.6
9.7
9.7
9.7
9.2
8.2
8.4
8.4
8.5
8.4
8.4
8.6
8.5
8.8
8.4
8.5
8.6
8.6
8.7
8.5
8.6
8.7
8.6
8.7
8.7
8.8
8.7
Max.A
4.3
5
7.2
9.9
6.8
7.9
9.4
11.5
9.2
10.3
11.6
11.6
11.6
11.6
10.4
11.3
11
11.3
11
11.3
11.3
11.5
11.5
11.1
11.3
11.5
11.3
11.5
11.3
11.3
11.3
11.3
11.5
11.3
11.7
11.7
3.08
3.10
3.10
3.42
3.23
3.22
3.22
3.21
3.13
3.24
3.29
3.30
3.32
3.50
3.33
3.61
3.64
3.78
3.63
3.66
3.72
3.69
3.63
3.65
3.67
3.72
3.72
3.68
3.63
3.61
3.68
3.72
3.68
3.68
3.63
3.68
B
B
B
A
A
A
A
A
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Note1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
83
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
HeatingMH070FXEA4BIndoor Unit Combination
Numberof Unit
1 Unit
2 Unit
3 Unit
4 Unit
Heating Capacity(W) Capacity CurrentPower Consumption
ACOP EG
2200
2600
3800
5600
2200
2200
2200
2200
2900
2900
2900
3800
3800
5600
2200
2200
2200
2200
2200
2200
2200
2200
2200
2900
2900
2900
2900
3800
2200
2200
2200
2200
2200
2200
2200
2900
B
-
-
-
-
2200
2900
3800
5600
2900
3800
5600
3800
5600
5600
2200
2200
2200
2200
2900
2900
2900
3800
3800
2900
2900
2900
3800
3800
2200
2200
2200
2200
2200
2900
2900
2900
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2200
2900
3800
5600
2900
3800
5600
3800
5600
2900
3800
5600
3800
3800
2200
2200
2200
2900
2900
2900
2900
2900
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2200
2900
3800
2900
3800
2900
3800
2900
%
26%
30%
44%
65%
51%
59%
70%
91%
67%
78%
99%
88%
109%
130%
77%
85%
95%
116%
93%
103%
124%
114%
135%
101%
112%
133%
122%
133%
102%
110%
121%
119%
129%
127%
137%
135%
Total Total
2200
2600
3800
5600
4400
5100
6000
7800
5800
6700
8500
7600
9400
11200
6600
7300
8200
10000
8000
8900
10700
9800
11600
8700
9600
11400
10500
11400
8800
9500
10400
10200
11100
10900
11800
11600
A
2500
2900
3800
5600
2200
2200
2200
2200
2900
2900
2729
3800
3283
4250
2200
2200
2200
1892
2200
2042
1768
1872
1631
2750
2516
2188
2375
2867
2063
1927
1819
1855
1705
1736
1603
2150
B
-
-
-
-
2200
2900
3800
5600
2900
3800
5271
3800
4837
4250
2200
2200
2200
1892
2900
2691
2331
3234
2817
2750
2516
2188
3112
2867
2063
1927
1819
1855
1705
2288
2114
2150
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2200
2900
3800
4816
2900
3119
4501
3234
3120
2750
3297
3121
3112
2867
2063
1927
1819
2445
2247
2288
2114
2150
Min.W
1790
1820
1930
2080
1980
2040
2110
2200
2100
2170
2200
2200
2200
2200
2170
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
Nom.W
2500
2900
3800
5600
4400
5100
6000
7800
5800
6700
8000
7600
8120
8500
6600
7300
8200
8600
8000
8260
8600
8340
8600
8250
8330
8600
8600
8600
8250
8320
8600
8600
8600
8600
8600
8600
3220
3680
4600
6440
5060
5870
6900
9130
6670
8040
9600
9120
9740
10200
7590
8400
9590
10300
9360
9670
10300
9760
10300
9650
9740
10300
10300
10300
9660
9730
10300
10300
10300
10300
10300
10300
Max.Ml
Min.W
580
590
600
610
600
610
610
620
610
610
620
620
620
620
610
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
Nom.W
950
1100
1250
1670
1220
1410
1760
2150
1600
1940
2210
2100
2250
2250
1830
1880
1930
1960
1900
1930
1970
1950
2000
1930
1950
1980
1980
2000
1930
1950
2000
1970
2000
2000
2000
2000
Max.W
1330
1500
1810
2370
1530
1700
2110
2700
1930
2330
2650
2510
2700
2740
2530
2590
2660
2700
2620
2660
2720
2690
2760
2660
2690
2730
2730
2760
2660
2690
2760
2720
2760
2760
2760
2760
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2063
2540
3142
2445
2944
2288
2769
2150
2500
2900
3800
5600
4400
5100
6000
7800
5800
6700
8000
7600
8120
8500
6600
7300
8200
8600
8000
8260
8600
8340
8600
8250
8330
8600
8600
8600
8250
8320
8600
8600
8600
8600
8600
8600
Min.A
2.7
2.7
2.7
2.8
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
Nom.A
4.3
5
5.7
7.6
5.6
6.5
8.1
9.8
7.3
8.9
10.1
9.6
10.3
10.3
8.4
8.6
8.8
9
8.7
8.8
9
8.9
9.2
8.8
8.9
9.1
9.1
9.2
8.8
8.9
9.2
9
9.2
9.2
9.2
9.2
Max.A
6.1
6.9
8.3
10.8
7
7.8
9.7
12.4
8.8
10.7
12.1
11.5
12.4
12.5
11.6
11.9
12.2
12.4
12
12.2
12.4
12.3
12.6
12.2
12.3
12.5
12.5
12.6
12.2
12.3
12.6
12.4
12.6
12.6
12.6
12.6
2.63
2.64
3.04
3.35
3.61
3.62
3.41
3.63
3.63
3.45
3.62
3.62
3.61
3.78
3.61
3.88
4.25
4.39
4.21
4.28
4.37
4.28
4.30
4.27
4.27
4.34
4.34
4.30
4.27
4.27
4.30
4.37
4.30
4.30
4.30
4.30
E
E
D
C
A
A
B
A
A
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Note1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
84
FJM AIR CONDITIONERS
Combination Table
CoolingMH080FXEA4BIndoor Unit Combination
Numberof Unit
1 Unit
2 Unit
3 Unit
4 Unit
Cooling Capacity(W) Capacity CurrentPower Consumption
AEER EG
2000
2600
3500
5200
2000
2000
2000
2000
2600
2600
2600
3500
3500
5200
2000
2000
2000
2000
2000
2000
2000
2000
2000
2600
2600
2600
2600
2600
3500
3500
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2600
2600
2600
B
-
-
-
-
2000
2600
3500
5200
2600
3500
5200
3500
5200
5200
2000
2000
2000
2000
2600
2600
2600
3500
3500
2600
2600
2600
3500
3500
3500
3500
2000
2000
2000
2000
2000
2000
2000
2000
2600
2600
2600
2600
2600
2600
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2000
2600
3500
5200
2600
3500
5200
3500
5200
2600
3500
5200
3500
5200
3500
5200
2000
2000
2000
2000
2600
2600
2600
3500
2600
2600
3500
2600
2600
3500
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2000
2600
3500
5200
2600
3500
5200
3500
2600
3500
3500
2600
3500
3500
%
25%
33%
44%
65%
50%
58%
69%
90%
65%
76%
98%
88%
109%
130%
75%
83%
94%
115%
90%
101%
123%
113%
134%
98%
109%
130%
120%
141%
131%
153%
100%
108%
119%
140%
115%
126%
148%
138%
123%
134%
145%
130%
141%
153%
Total Total
2000
2600
3500
5200
4000
4600
5500
7200
5200
6100
7800
7000
8700
10400
6000
6600
7500
9200
7200
8100
9800
9000
10700
7800
8700
10400
9600
11300
10500
12200
8000
8600
9500
11200
9200
10100
11800
11000
9800
10700
11600
10400
11300
12200
A
2400
2600
3500
5200
2000
2000
2000
2000
2600
2600
2400
3500
2957
3825
2000
2000
2000
1663
2000
1864
1573
1698
1495
2510
2274
1940
2083
1841
2667
2295
1888
1767
1617
1429
1663
1531
1356
1455
1573
1495
1379
1940
1841
1705
B
-
-
-
-
2000
2600
3500
5200
2600
3500
4800
3500
4393
3825
2000
2000
2000
1663
2600
2423
2046
2971
2617
2510
2274
1940
2804
2478
2667
2295
1888
1767
1617
1429
1663
1531
1356
1455
2046
1944
1793
1940
1841
1705
C
-
-
-
-
-
-
-
-
-
-
-
-
-
2000
2600
3500
4324
2600
3262
4091
2971
3888
2510
3061
3880
2804
3681
2667
3410
1888
1767
1617
1429
2162
1990
1763
2545
2046
1944
2414
1940
1841
2295
Min.W
1470
1520
1600
1750
1640
1690
1770
1900
1750
1820
1900
1900
1900
1900
1810
1870
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
Nom.W
2400
2600
3500
5200
4000
4600
5500
7200
5200
6100
7200
7000
7350
7650
6000
6600
7500
7650
7200
7550
7710
7640
8000
7530
7610
7760
7690
8000
8000
8000
7550
7600
7680
8000
7650
7730
8000
8000
7710
8000
8000
7760
8000
8000
3000
3480
4200
6240
4800
5520
6600
8640
6240
7320
8640
8400
8820
9180
7200
7920
9000
9180
8640
9060
9250
9160
9300
9030
9130
9300
9230
9300
9300
9300
9050
9120
9220
9300
9180
9280
9300
9300
9250
9300
9300
9300
9300
9300
Max.Ml
Min.W
380
390
400
420
410
420
430
580
420
440
580
580
580
580
440
440
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
580
Nom.W
780
840
1130
1520
1240
1430
1710
2240
1660
1900
2240
2180
2290
2380
1850
2000
2220
2190
2150
2150
2190
2190
2260
2110
2140
2210
2180
2260
2260
2300
2140
2140
2180
2300
2190
2200
2300
2280
2190
2260
2300
2220
2300
2300
Max.W
950
1100
1580
2160
1490
1720
2050
2690
2000
2260
2690
2620
2750
2860
2310
2500
2780
2730
2680
2690
2730
2730
2820
2640
2690
2780
2730
2870
2820
2910
2690
2690
2730
2870
2730
2780
2870
2870
2730
2820
2870
2780
2870
2910
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1888
2298
2829
3714
2162
2679
3525
2545
2046
2617
2414
1940
2478
2295
2400
2600
3500
5200
4000
4600
5500
7200
5200
6100
7200
7000
7350
7650
6000
6600
7500
7650
7200
7550
7710
7640
8000
7530
7610
7760
7690
8000
8000
8000
7550
7600
7680
8000
7650
7730
8000
8000
7710
8000
8000
7760
8000
8000
Min.A
1.7
1.8
1.8
1.9
1.9
1.9
2
2.7
1.9
2
2.7
2.7
2.7
2.7
2
2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
Nom.A
3.6
3.8
5.2
7
5.7
6.5
7.8
10.3
7.6
8.7
10.3
10
10.5
10.9
8.5
9.2
10.2
10
9.8
9.8
10
10
10.3
9.7
9.8
10.1
10
10.3
10.3
10.5
9.8
9.8
10
10.5
10
10.1
10.5
10.4
10
10.3
10.5
10.2
10.5
10.5
Max.A
4.3
5
7.2
9.9
6.8
7.9
9.4
12.3
9.2
10.3
12.3
12
12.6
13.1
10.6
11.4
12.7
12.5
12.3
12.3
12.5
12.5
12.9
12.1
12.3
12.7
12.5
13.1
12.9
13.3
12.3
12.3
12.5
13.1
12.5
12.7
13.1
13.1
12.5
12.9
13.1
12.7
13.1
13.3
3.08
3.10
3.10
3.42
3.23
3.22
3.22
3.21
3.13
3.21
3.21
3.21
3.21
3.21
3.24
3.30
3.38
3.49
3.35
3.51
3.52
3.49
3.54
3.57
3.56
3.51
3.53
3.54
3.54
3.48
3.53
3.55
3.52
3.48
3.49
3.51
3.48
3.51
3.52
3.54
3.48
3.50
3.48
3.48
B
B
B
A
A
A
A
A
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Note1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
85
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Indoor Unit CombinationNumberof Unit
1 Unit
2 Unit
3 Unit
4 Unit
Heating Capacity(W) Capacity CurrentPower Consumption
ACOP EG
2200
2900
3800
5600
2200
2200
2200
2200
2900
2900
2900
3800
3800
5600
2200
2200
2200
2200
2200
2200
2200
2200
2200
2900
2900
2900
2900
2900
3800
3800
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2900
2900
2900
B
-
-
-
-
2200
2900
3800
5600
2900
3800
5600
3800
5600
5600
2200
2200
2200
2200
2900
2900
2900
3800
3800
2900
2900
2900
3800
3800
3800
3800
2200
2200
2200
2200
2200
2200
2200
2200
2900
2900
2900
2900
2900
2900
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2200
2900
3800
5600
2900
3800
5600
3800
5600
2900
3800
5600
3800
5600
3800
5600
2200
2200
2200
2200
2900
2900
2900
3800
2900
2900
3800
2900
2900
3800
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2200
2900
3800
5600
2900
3800
5600
3800
2900
3800
3800
2900
3800
3800
%
24%
31%
41%
60%
47%
55%
65%
84%
62%
72%
91%
82%
101%
120%
71%
78%
88%
108%
86%
96%
115%
105%
125%
94%
103%
123%
113%
132%
123%
142%
95%
102%
112%
131%
110%
119%
139%
129%
117%
127%
137%
125%
134%
144%
Total Total
2200
2900
3800
5600
4400
5100
6000
7800
5800
6700
8500
7600
9400
11200
6600
7300
8200
10000
8000
8900
10700
9800
11600
8700
9600
11400
10500
12300
11400
13200
8800
9500
10400
12200
10200
11100
12900
12000
10900
11800
12700
11600
12500
13400
A
2500
2900
3800
5600
2200
2200
2200
2200
2900
2900
2729
3800
3283
4250
2200
2200
2200
1896
2200
2109
1785
1931
1764
2840
2595
2226
2392
2193
2910
2677
2130
1987
1830
1677
1864
1726
1586
1610
1754
1633
1611
2188
2158
2013
B
-
-
-
-
2200
2900
3800
5600
2900
3800
5271
3800
4837
4250
2200
2200
2200
1896
2900
2779
2353
3335
3047
2840
2595
2226
3134
2873
2910
2677
2130
1987
1830
1677
1864
1726
1586
1610
2312
2153
2124
2188
2158
2013
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2200
2900
3800
4827
2900
3642
4543
3335
4490
2840
3400
4298
3134
4234
2910
3945
2130
1987
1830
1677
2456
2276
2091
2780
2312
2153
2783
2188
2158
2637
Min.W
1790
1820
1930
2080
1980
2040
2110
2200
2100
2170
2200
2200
2200
2200
2170
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
Nom.W
2500
2900
3800
5600
4400
5100
6000
7800
5800
6700
8000
7600
8120
8500
6600
7300
8200
8620
8000
8530
8680
8600
9300
8520
8590
8750
8660
9300
8730
9300
8520
8580
8650
9300
8640
8710
9300
8780
8690
8760
9300
8750
9300
9300
3220
3680
4600
6440
5060
5870
6900
9130
6670
7710
9360
8740
9500
9950
7590
8400
9590
10090
9360
9980
10150
10070
10900
9960
10050
10900
10130
10900
10220
10900
9970
10040
10120
10900
10100
10190
10900
10270
10170
10250
10900
10240
10900
10900
Max.Ml
Min.W
580
590
600
610
600
610
610
620
610
610
620
620
620
620
610
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
620
Nom.W
950
1110
1250
1670
1220
1410
1760
2150
1600
1940
2210
2090
2250
2340
1830
1950
2150
2140
2080
2100
2140
2140
2150
2090
2100
2140
2140
2150
2150
2180
2100
2100
2140
2200
2140
2140
2200
2180
2140
2180
2200
2140
2180
2200
Max.W
1330
1500
1810
2370
1530
1700
2110
2580
1930
2330
2600
2510
2650
2750
2220
2340
2570
2610
2500
2690
2740
2740
2750
2680
2690
2740
2740
2750
2750
2790
2690
2690
2740
2820
2740
2740
2820
2790
2740
2790
2820
2740
2790
2820
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2130
2619
3161
4269
2456
2982
4037
2780
2312
2821
2783
2188
2827
2637
2500
2900
3800
5600
4400
5100
6000
7800
5800
6700
8000
7600
8120
8500
6600
7300
8200
8620
8000
8530
8680
8600
9300
8520
8590
8750
8660
9300
8730
9300
8520
8580
8650
9300
8640
8710
9300
8780
8690
8760
9300
8750
9300
9300
Min.A
2.7
2.7
2.7
2.8
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
Nom.A
4.3
5.1
5.7
7.6
5.6
6.5
8.1
9.8
7.3
8.9
10.1
9.6
10.3
10.7
8.4
8.9
9.8
9.8
9.5
9.6
9.8
9.8
9.8
9.6
9.6
9.8
9.8
9.8
9.8
10
9.6
9.6
9.8
10.1
9.8
9.8
10.1
10
9.8
10
10.1
9.8
10
10.1
Max.A
6.1
6.9
8.3
10.8
7
7.8
9.7
11.8
8.8
10.7
11.9
11.5
12.1
12.6
10.2
10.7
11.8
11.9
11.4
12.3
12.5
12.5
12.6
12.3
12.3
12.5
12.5
12.6
12.6
12.8
12.3
12.3
12.5
12.9
12.5
12.5
12.9
12.8
12.5
12.8
12.9
12.5
12.8
12.9
2.63
2.61
3.04
3.35
3.61
3.62
3.41
3.63
3.63
3.45
3.62
3.64
3.61
3.63
3.61
3.74
3.81
4.03
3.85
4.06
4.06
4.02
4.33
4.08
4.09
4.09
4.05
4.33
4.06
4.27
4.06
4.09
4.04
4.23
4.04
4.07
4.23
4.03
4.06
4.02
4.23
4.09
4.27
4.23
E
E
D
C
A
A
B
A
A
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
HeatingMH080FXEA4B
Note1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
86
FJM AIR CONDITIONERS
S-NE T miniS-NET mini supports up to 4 Data Management Servers to provide the same remote controlfunctions as S-NET3 and this touch screen controller can be connected directly with system airconditioner through centralized controller or interface modules allowing up to 256 indoor units.
� Dynamic compatibility options (DMS, centralized controller, interface module)
• Control and monitoring of up to 256 indoor units
• Detailed cycling information monitoring
• Schedule function (Weekly, Daily)
• USB keyboard support
• Error display
• 7-inch wide LCD display
• Temperature limit setting
• Touch screen
• Zone control
• Child-lock setting
• Operation mode lock
• External contact control
S-NET mini
Dynamic Compatibility Option
S-NET mini
Supports 16
InterfaceModules
�
Supports 4 DMSs �
Supports 16
CentralizedControllers
�
87
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Centralized control system is more than enough to control multiple groups and
individual indoor units. With Samsung’s centralized controller, conveniently and
efficiently control the multiple or individual indoor units.
Centralized Controller
� Maximum 16 group controls (Maximum 256 Indoor units)
� Unified/individual indoor unit control (On/Off)
� Wireless/wired remote control restriction
� Cooling/heating mode control
� Indoor unit error display
Control Systems Function Icon
MCM-A202B
Function Controller
� Control and monitoring of up to 16 indoor unit groups
MCM-A100
To use Function Controller, it requires to be connected toMCM-A202A
MCM-A202B has compatibility with MCM-A202A
Interface Module
� Communicator between indoor/outdoor units and the centralized controller
MIM-B04A
ON/OFF, OPERATION MODE, FAN SPEED, AIRFLOW, TEMPERATURE SETTING
OperationOperationOperationOperation INDIVIDUAL AND GROUPCONTROL (MAXIMUM 16INDOOR UNITS)
GroupGroupGroupGroup
ErrorErrorErrorErrorERROR DISPLAY FILTER REPLACEMENT
ALARM RESETFilterFilterFilterFilter
OperationOperationOperationOperation ErrorErrorErrorError FilterFilterFilterFilter
Centralized Control System
88
FJM AIR CONDITIONERS
Control Systems Function Icon
Individual Control SystemThere is a variety of wired and wireless
controllers for convenient use of your
air conditioners. With different control
options, you can choose one that suits
your air conditioning environment.
ON/OFF, OPERATION MODE, FAN SPEED, AIRFLOW, TEMPERATURE SETTING
OperationOperationOperationOperation
SLEEP & SILENT MODESilentSilentSilentSilent
BUILT-IN ROOM TEMPERATURE SENSOR
CHILD LOCKLockLockLockLock
AUTOMATIC STOP MODEAuto StopAuto StopAuto StopAuto Stop
WIRELESS REMOTECONTROL RESTRICTIONWirelessWirelessWirelessWireless
CLEAR & BRIGHT SCREENWITH LCD BACKLIGHT
BrightBright
INDIVIDUAL AND GROUPCONTROL (MAXIMUM 16INDOOR UNITS)
GroupGroupGroupGroup
ErrorErrorErrorErrorERROR DISPLAY
FILTER REPLACEMENTALARM RESET
FilterFilterFilterFilter
OperationOperationOperationOperation SilentSilentSilentSilent LockLockLockLock Auto StopAuto StopAuto StopAuto Stop
WirelessWirelessWirelessWireless
BrightBrightGroupGroupGroupGroup ErrorErrorErrorError FilterFilterFilterFilter
Wired Remote Controller
� Unified controller (A/C, ERV, A/C+ERV)
• Different permission levels
• Weekly schedule setting (A/C, ERV, A/C+ERV)
• Exception date setting
MWR-WE00 (Multi function)
OperationOperationOperationOperation SilentSilentSilentSilentLockLockLockLock Auto StopAuto StopAuto StopAuto Stop
� Simple schedule control
� Different permission levels
MWR-WH00
Wireless Remote Controller
� Simple schedule control
� Wide display
� Soft touch button
MR-CH01OperationOperationOperationOperation FilterFilterFilterFilter
89
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Guest Room Management SystemThe Guest Room Management System is a smart way to save energy and
money. When the Key Tag is in place, the air conditioner is activated. When the
Key Tag is removed, the air conditioner switches off. Now you can avoid
cooling an unoccupied room and save energy.
Key-Tag
On/Off
Window OpenSensor
MalfunctionAlarm
External deviceControl
On/Off On/OffError
(Wall mounted type indoor unit : Only the model including EEV supports state output function)
Example
External Contact Interface Module
� Direct indoor unit control by external contact signal
� Window-synchronized indoor unit control
� Emergency control with simple contact input
� Indoor unit operation/error state output throughrelay contacts
MIM-B14
90
FJM AIR CONDITIONERS
Classification Product Model Image Application Model
IntegratedManagementSystem
Controller
InterfaceModule
DMS2 MIM-D00A DVM Series, FJM, CAC, ERV
DVM Series, FJM, CAC, ERV
DVM Series, FJM, CAC, ERV
S-NET3 MST-P3P
S-NET mini MST-S3W
DVM Series, FJMSiM MIM-B12
CentralizedControlSystem
InterfaceModule
DVM Series, FJM, CAC, ERV
DVM Series, FJM, CAC
Mini DVM(R410A), DVM PLUS II, DVM PLUSII HR, DVM PLUS III, DVM PLUS III HR, FJM,ERV
MCM-A202B
Controller
Centralized Controller
MCM-A100Function Controller
MIM-B13B
Centralized Control Interface Module
DVM, DVM PLUS, DVM HR, CACMIM-B04A
DVM Series (Except HR models)MCM-C200Operation Mode Selection Switch
DVM Series, FJMPower Distribution Unit
DVM Series : Mini DVM, DVM, DVM PLUS, DVM HR, DVM PLUS II, DVM PLUS IIHR, DVM PLUS III, DVM PLUS IIIHR
MCM-B102
CAC, Mini DVM(R410A), DVM PLUS II, DVM PLUS II HR, DVM PLUS III, DVM PLUS III HR, FJM(Non MH���FKEA)
External Contact Interface Module MIM-B14
Building ManagementSystem Lonworks Interface Module MIM-B07 DVM Series, FJM
Power Distribution
DVM Series, FJM (Non MH���FXEA�B)Key-tag Interface Module MIM-B02Guest RoomManagementSystem
IndividualControlSystem
Controller
Wireless Remote Controller MR-CH01Cassette, Ceiling, Duct (Receiverneeded), Console (Included)
Cassette, Wall Mounted, Ceiling, Duct, Console
Duct (For Wireless Remote Controller)
Duct (For Wireless Remote Controller)
Centralized Controller
Wired Remote Controller MWR-WH00
Cassette, Wall Mounted, Ceiling, Duct, Console
Simplified Wired Remote Controller MWR-SH00
Wireless SignalReceiver Kit
MRK-A00Wireless Signal Receiver
Receiver Wire MRW-10A
7-day Scheduler MWR-BS00
Cassette, Wall Mounted, Ceiling, Duct, ConsoleWired Remote Controller (Multi Function) MWR-WE00
Cassette, Wall Mounted, Ceiling, Duct, ConsoleExternal Room Sensor MRW-TA
Accessories
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Icon IndexWall-mounted Type Icon
Auto Roof ShutterAir conditioner automatically sealsoff to prevent dirt infiltration.
DNA FilterThe DNA structure possesses qualities inabsorbing and eliminating microscopiccarcinogenic agents.
Good’sleep IIControl the air temperature during yoursleep to enjoy a comfortable sleep andrefreshed wake up.
Cassette Type Icon
WIDE BLADEWider blades provide moreeven cooling power.
CEILING SOILINGPREVENTIONNewly designed panel preventsceiling contamination.
HIGH LIFT-UP DRAIN PUMPLift-up condensed water upto 750mm higher than anyother competitor.
FRESH AIR INTAKEOptional air intake motor bringsin fresh air from outside.
QUICK CONNECTIONOF DRAIN PIPEUnique drain pipe connectionis easy to install.
SUB DUCTThe Sub Duct makes it easyto provide air conditioning toa nearby smaller space.
WIDEWIDEWIDEWIDE
HIGHHIGHHIGHHIGH SUB DUCTSUB DUCTSUB DUCTSUB DUCTQUICKQUICKQUICKQUICK
FRESHFRESHFRESHFRESH
Duct Type Icon
Floor & Convertible Type Icon
Control Systems Icon
ANTI-BACTERIA FILTERAnti-bacteria Filter traps dust particles and suppresses proliferationof moulds and bacteria.
EASY FILTER CLEANINGFilter cleaning indicator willlet you know when the filterneeds to be cleaned.
HIGH LIFT-UP DRAIN PUMPLift-up condensed water upto 750mm higher than anyother competitor.
SMART PRESSURE CONTROLAdjusts fan speed to provideconstant cooling and heatingperformance.
WIRED REMOTE CONTROLLERDefault wired remote controlleris provided.
BACTERIABACTERIABACTERIABACTERIAHIGHHIGHHIGHHIGH
WiredWiredWiredWired
INTERIOR DESIGNThe clean, modern designcomplements any decor.
LIGHT WEIGHT UNITExtremely lightweight, so maintenance and installation is easy.
ANTI-BACTERIA FILTERAnti-bacteria Filter traps dustparticles and suppresses proliferation of moulds and bacteria.
AUTO CHANGEOVERAutomatically changes operationmode according to temperaturesetting.
FLEXIBLE PIPEINSTALLATIONThe pipe can be installedin 6 different places formore placement options.
SILENT MODEIndoor and outdoor unitoperates silently.
WIRELESS REMOTECONTOLLERDefault wireless remote controlleris provided.
INTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN BACTERIABACTERIABACTERIABACTERIA
LIGHTLIGHTLIGHTLIGHT
AUTOAUTOAUTOAUTO
Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation WirelessWirelessWirelessWireless
ON/OFF, OPERATION MODE, FAN SPEED, AIRFLOW, TEMPERATURE SETTING
OperationOperationOperationOperation SLEEP & SILENT MODESilentSilentSilentSilent
BUILT-IN ROOM TEMPERATURE SENSOR
CHILD LOCKLockLockLockLock
AUTOMATIC STOP MODEAuto StopAuto StopAuto StopAuto Stop
WIRELESS REMOTECONTROL RESTRICTIONWirelessWirelessWirelessWireless
CLEAR & BRIGHT SCREENWITH LCD BACKLIGHT
BrightBrightINDIVIDUAL AND GROUPCONTROL (MAXIMUM 16INDOOR UNITS)
GroupGroupGroupGroup
ErrorErrorErrorErrorERROR DISPLAYFILTER REPLACEMENT
ALARM RESETFilterFilterFilterFilter
Virus Doctor generates Hydrogenatoms and Oxygen ions to createhealthier air.
air conditioning centre159 Edinburgh Avenue Slough SL1 4UE Tel: 01753 495715 Fax: 01753 495716 Email: [email protected]
HRP Service CentresHRP Limited – BedfordUnit B6 Manton Centre Manton Lane BedfordMilton Keynes MK41 7PXTel: 01234 272702 Fax: 01234 273424Email: [email protected]
HRP Limited – BirminghamUnits 16/17 Fulford Drive Minworth IndustrialEstate Sutton Coldfield B76 1DR Tel: 0121 313 6720 Fax: 0121 313 2801 Email: [email protected]
HRP Limited – Bristol100 The Quadrant Ash Ridge Road Bristol BS32 4QATel: 01454 456 430 Fax: 01454 456 431 Email: [email protected]
HRP Limited – Bury St EdmundsRougham Industrial Estate Bury St EdmundsSuffolk IP30 9XA Tel: 01359 270888 Fax: 01359 271770 Email: [email protected]
HRP Limited – FarehamUnit 2 Stephenson Road SegensworthFareham Hampshire PO15 5RUTel: 01329 443515 Fax: 01329 443511 Email: [email protected]
HRP Limted – Glasgow140 St Andrews Road Pollockshields Glasgow G41 1 PPTel: 0141 420 1606 Fax: 0141 420 1755 Email: [email protected]
HRP Limited – LeedsUnit 1 Aintree Court Hunslet Business ParkNational Road Leeds LS10 1TFTel: 0113 277 5000 Fax: 0113 201 6201 Email: [email protected]
HRP Limited – MertonUnit 2 Saxon Business Centre WindsorAvenue Merton London SW19 2RRTel: 020 8544 1010 Fax: 020 8544 9717 Email: [email protected]
HRP Limited – NewcastleUnit K4 Hamar Close Tyne Tunnel TradingEstate North Shields Tyne and Wear NE29 7XBTel: 0191 258 3492 Fax: 0191 257 3982 Email: [email protected]
HRP Limited – Norwich4/6 Murrayfield Road Fifers Lane Norwich Norfolk NR6 6NQTel: 01603 409616 Fax: 01603 400464 Email: [email protected]
HRP Limited – SheffieldUnit 2 Brightside 443 Brightside LaneSheffield South Yorkshire S9 2RSTel: 0114 244 8222 Fax: 0114 244 0400 Email: [email protected]
HRP Limited – Slough159 Edinburgh Avenue Slough SL1 4UE Tel: 01753 495710 Fax: 01753 495711 Email: [email protected]
HRP Limited – SouthamptonUnit 2 South Hampshire Industrial ParkSalisbury Road Totton Southampton SO40 3SATel: 023 8086 9966 Fax: 023 8086 4205 Email: [email protected]
HRP Limited – SwanleyTeardrop Centre London Road Swanley Kent BR8 8TJ Tel: 01322 614811 Fax: 01322 614733 Email: [email protected]
HRP Limited – WalthamstowUnit 12 Waltham Park Way Billet RoadWalthamstow London E17 5DUTel: 020 8531 9321 Fax: 020 8531 8155 Email: [email protected]
HRP Limited – Warrington5 Rivington Court Hardwick Grange Warrington Cheshire WA1 4RTTel: 01925 837688 Fax: 01925 831093 Email: [email protected]
www.samsungaccentre.com