Introduction
Cisco Integrated Service Router Generation 2
The Cisco Integrated Service Router Generation 2 (ISR G2) is a family of branch-office routers. It has more processing powerand better WAN performance than the models in the previous ISR family. Supported routers in the family can run a more powerfulESXi 4 or ESXi 5 virtualization platform via the SRE modules which can be plugged into the router.
For more information on the ISR/G2 family of branch-routers, visit the Cisco product page athttp://www.cisco.com/en/US/products/ps10906/Products_Sub_Category_Home.html#~one
Cisco Services-Ready Engine
A summary of the Cisco Services-Ready Engine (SRE) can be found at the Cisco website athttp://www.cisco.com/en/US/prod/collateral/modules/ps10598/data_sheet_c78-553913.html .
The Cisco
Services-Ready Engine (SRE) modules are router blades for the Cisco Integrated Services Routers Generation 2(ISR G2) that provide the capability to host Cisco, third-party, and custom applications. The modules have their own processors,storage, network interfaces, and memory that operate independently of the host router resources, helping ensure maximumconcurrent routing and application performance.
Figure 1
Cisco 900/910 Cisco SRE Module
This paper is a deployment guide for configuring Riverbed Virtual Steelhead (VSH) on the SRE. It begins with some informationfor new deployments of SRE (especially as it pertains to VSH), then provides some network integration examples. As thevirtualization environment is VMware ESXi, this paper will not concentrate on installing VSH on ESXi (please refer to thedocumentation on the Riverbed Support Site athttps://support.riverbed.com/docs/appliance.htm ). Instead, this paper willconcentrate on the important parts around VSH in this specific ESXi environment: SRE configuration and the various WCCPoptions.
The SRE-V image is a Cisco-prepared version of ESXi. You must use the Cisco version of ESXi on the SRE.
This document assumes you have basic understand of ESXi, VSH, and WCCP (as it pertains to Riverbed Steelhead appliances).
In this paper, we document the steps we took to get VSH running in the SRE environment. Some of these steps may need to bealtered or may not apply in your environment.
Checklist for Administrators with VSH Experience
The following is a list of pertinent information in this documentation for those administrators who already have extensive VSHexperience:
Installing the SRE module, configuring basic management IP addresses Installing the SRE softwaredo not use the FTP service in Microsoft Windows Server 2008R2 operating system
http://www.cisco.com/en/US/products/ps10906/Products_Sub_Category_Home.html#~onehttp://www.cisco.com/en/US/products/ps10906/Products_Sub_Category_Home.html#~onehttp://www.cisco.com/en/US/prod/collateral/modules/ps10598/data_sheet_c78-553913.htmlhttp://www.cisco.com/en/US/prod/collateral/modules/ps10598/data_sheet_c78-553913.htmlhttps://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htmhttp://www.cisco.com/en/US/prod/collateral/modules/ps10598/data_sheet_c78-553913.htmlhttp://www.cisco.com/en/US/products/ps10906/Products_Sub_Category_Home.html#~one -
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
3/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 2
vmnic mapping to router/SRE entities VSH model support
Configuring the SRE on the Cisco ISR G2 router for ESXiIn this section, we follow many of the steps in Cisco SRE-V Self Training guide, located on the Cisco website athttp://www.cisco.com/en/US/prod/collateral/ps10265/ps11273/installation_guide_c07-640002.html#wp9000192 .
Our test setup has a 3945 ISR G2 and an SRE 910 blade with 8GB RAM (2x4GB) installed.
Install the SRE blade
Install the SRE module into an available slot on the ISR G2 router. In our test setup, we installed the module into Slot 4.
For more information on installing the SRE Service Module into the router, refer to documentation on the Cisco website athttp://www.cisco.com/en/US/docs/interfaces_modules/services_modules/sre_v/1.0/user/guide/hardware.html .
Configure the management network
In our test setup, interface Gi0/3 on the router has been designated as our management interface.
The first part of configuration is to setup IP addressing such that the SRE-V software can be installed via ftp. We have an ftpserver installed on Windows 2008R2 Server on a management network. We will configure the management interface on thesame network as the ftp server.
gi0/3: mgmt
10.32.146.196
Windows 2008R2E
Cisco 3945 ISR G2
mgmt: 10.32.146.217
Figure 2Management IP address configuration for ftp access
http://www.cisco.com/en/US/prod/collateral/ps10265/ps11273/installation_guide_c07-640002.html#wp9000192http://www.cisco.com/en/US/prod/collateral/ps10265/ps11273/installation_guide_c07-640002.html#wp9000192http://www.cisco.com/en/US/docs/interfaces_modules/services_modules/sre_v/1.0/user/guide/hardware.htmlhttp://www.cisco.com/en/US/docs/interfaces_modules/services_modules/sre_v/1.0/user/guide/hardware.htmlhttp://www.cisco.com/en/US/docs/interfaces_modules/services_modules/sre_v/1.0/user/guide/hardware.htmlhttp://www.cisco.com/en/US/prod/collateral/ps10265/ps11273/installation_guide_c07-640002.html#wp9000192 -
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
4/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 3
Router configuration:interface GigabitEthernet0/3description mgmtip address 10.32.146.196 255.255.255.0duplex autospeed auto
!
Make sure you can ping the FTP server from the ISR G2.
Configure the SRE management network
ESXi interfaces cannot be tied to the Gigabit Ethernet interfaces of the router. They can use SM/0, SM/1, or theexternal gigabit interface on the SRE blade. In this section we will configure the SRE management network (which will also be thenetwork for ESXi) on SM4/0.
After installing the SRE module, verify the following interfaces exist: SM/0 and SM/1. In our test setup we instal ledthe SRE in slot 4, so we verify the presence of SM4/0 and SM4/1 using the sh interfaces command.
In our test setup, we configured SM4/0 as an internal network for ESXi and VSH. SM4/0 will have 2 IP addresses: one for therouter side of the SM interface, and one for the ESXi side.
gi0/3: mgmt
10.32.146.196
Windows 2008R2E
Cisco 3945 ISR G2
mgmt:
10.32.146.217
sm 4/0
(internal)
ESXi
10.1.20.1
SRE
SRE External Interface
vmnic1
10.1.20.2
Figure 3Management IP address configuration for ftp access, adding SM interface
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
5/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 4
Router configuration:interface SM4/0ip address 10.1.20.1 255.255.255.0service-module ip address 10.1.20.2 255.255.255.0service-module ip default-gateway 10.1.20.1
!
Prepare the ftp server with the SRE-V image
Obtain the SRE-V image
SRE images and release notes can be found at http://developer.cisco.com/web/srev/docs .Note that there are different images for 700/710 modules and the 900/910 modules.The SRE-V image is Cisco prepared version of ESXi. You must use the Cisco version of ESXi on the SRE.
Add the SRE-V files to the ftp server
Extract the contents of this file into a directory of an ftp server that the SRE can access with known ftp user credentials.Note: Do not use the Windows ftp service. Instead, use a third party ftp server such as FileZilla. The FTP server on WindowsServer 2008R2 does not support extended passive mode used by the SRE to obtain the image files.
In our test setup, on the Windows 2008R2 Server used for management, we created a user named share with password share,and configured that user to access C:\share. In C:\share we extracted the contents of the SRE-V image file into the C:\sharedirectory.
Figure 4Configuration of user account with root directory that contains the extracted SRE-V image files
Install the SRE-V infrastructure software
Router# service-module sm /0 install url
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
6/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 5
pkg file name>
In our test setup, we install the SRE-V infrastructure software on SM4/0 via
Router# service-module sm 4/0 install url ftp://share:[email protected]/sre-v-k9-r.SPA.smv.1.5.1.pkg
Note 1: We hot-plugged a SRE900 module into a 3945-E chassis. After running the install command, the prompt would hang for afew minutes then return. We had to power-cycle the whole chassis to have a successful install.Remember, the installation is done from the router, not from within an SRE console session.
The installation process will refer to the pkg file, which will refer it to other files in the same FTP directory. This directory can bethe FTP root directory or any subdirectory. The only requirement here is that all of the files from the distribution should beextracted into the same directory.
You will have to answer a few questions during the install. The most important one is (on the 900 and 910) decide whether toconfigure the disks as no raid, RAID0, or RAID1. More on this decision when we discuss performance.
If you have any problems during the installation, you can enable logging via:
Router#debug sre-install all
You can send the debug information to log via:
Router#Conf tRouter(config)#logging buffered debugging
Then view the current log via:
Router#show logging
Validate the installation of the SRE-V infrastructure software
Issue the service-module sm/0 statuscommand and verify the service module is in Steady State with ESXi running.
galvatron#service-module sm4/0 statusService Module is Cisco SM4/0Service Module supports session via TTY line 258Service Module is in Steady stateService Module heartbeat-reset is enabledGetting status from the Service Module, please wait..Cisco SRE-V Software 1.5.1.0VMware ESXi 4.1.0 build-348481 running on SRE
Module resource information:CPU Frequency: 1860 MHzMemory Size: 8162 MBDisk 0 Size: 500108 MBDisk 1 Size: 500108 MBDisk 2 Size: 2055 MB
No install/uninstall in progress
No local partition
galvatron#
With ESXi now running, you are ready to configure the management IP address for ESXi.
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
7/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 6
Configure Management Network on ESXi
You can enter the console of the SRE (now connected to ESXi) from the router via
Router# service-module sm/0 session
The default login/password for logging into ESXi is root/.
During the SRE-V installation, vmnic1 is automatically assigned the same IP address as what was specified in the service-
module ip addresscommand (see above). You should still log into the session/console to verify this was done. In the testsetup we verified that vmnic1 was chosen for management and already assigned an IP address of 10.1.20.2. Note that in ourtest setup, 10.1.20.1 is the router side of the SM 4/0 interface.
More information on the vmnicX interfaces (including why vmnic1 was selected in our test setup for ESXi management) can befound in the VSH/SRE Network Options section of this document.
Once you have logged out of ESXi, close the session via
CTRL+ALT+6 then x
You will be returned to the router cli. However the session to the ESXi console is still open. To close the session, enter thefollowing command:
Router# service-module sm/0 session clear
In our test setup, we clear the session via:galvatron#service-module sm4/0 session clear [confirm] [OK]
galvatron#
Install and Configure VSH on ESXi
With ESXi operational, you can now connect VMware vSphere to ESXi and install and configure VSH.
Please refer to the documentation on the Riverbed Support Site at https://support.riverbed.com/docs/appliance.htm .
In our test setup, the VMware vSphere has been installed on the Windows 2008R2 Server test machine. In order for theWin2008R2machine to reach the 10.1.20 network inside the sm4/0 interface, a static route needed to be defined on the WindowsServer 2008R2 machine via:
C:\windows> route ADD 10.1.20.0 MASK 255.255.255.0 10.32.146.196
This allows the Windows 2008R2 Server machine to reach the internal network on the SM interface via the management interfaceof the router (10.32.146.196 on gi0/3).
Vmnic Interface MapBefore we discuss virtual interfaces on VSH, we need to first understand what vmnics refer to which entities on the SRE.
https://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htm -
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
8/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 7
The following table maps ESXi vmnics to entities on the router:
vmnic mapping
vmnic0 External interface on the SRE module, not related to anything internal on the router.
vmnic1Internal management, tied to interface sm/0 . Due to router load, not recommended for optimization, but ok forprimary/aux management.
vmnic2 Internal Multi-Gigabit Fabric (mgf) interface, tied to interface sm/1, can be trunked for vlans on the router.Table 1ESXi vmnic to router/SRE interface mapping
Map ESXi Network Interfaces to VSH
In our test setup, we will map vmnic0 (see the Vmnic Interface Mapsection for a description of the various vmnics) to the WANinterface on VSH. vmnic0 is the external network interface on the SRE. Note that the external interface has no internalconnectivity to the rest of the router. The VSH and gi0/2 will be on a separate network (192.168.4.0).
On a new SRE-V installation, vmnic0 will not be assigned to a network. Via VMware vSphere, create a new vSwitch2 and assignvmnic0 to it. Then when adding the VSH VM, you can assign the WAN interface to vmnic0, via a network we will name as SRE-External.
Also by default, vmnic1 is not assigned. We will create a new vSwitch for vmnic1 so that we can assign it to the Primary interface
of the VSH. This new network will be called mgmt.
In our test setup, we will create the appropriate vSwitch/vmnic mappings prior to importing the VSH VM:
Figure 5ESXi network configuration after having added vSwitch2 (mapped to vmnic0/SRE external interface) and a mgmt. network for vmnic1.
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
9/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 8
We created the mgmtnetwork because the default Managememt Networkcannot be mapped to a VSH interface.
We can now import the VSH VM/OVA and are able to map the WAN to the SRE-External Interface/vmnic0 and the Primaryinterface to mgmt/vmnic1.
Figure 6Network mapping step during VSH OVA import
Even though we are not using the LAN and Aux interface in our test setup, there is currently no way to have VSH interface notassigned to any network. In this case just ignore the warning message.
Our test router has 4 Gigabit Ethernet interfaces. gi0/3 is connected to a separate management network, gi0/0 and gi0/1 will eachhandle LAN and WAN traffic, respectively. We will use the remaining gi0/2 interface as a dedicated interface to connect to theVSH.
To do this, we connect a network cable between gi0/2 and the external interface on the SRE.
Our new network diagram looks like this:
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
10/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 9
gi0/2
192.168.4.1
wccp router
gi0/3: mgmt
10.32.146.196
Windows 2008R2E
Cisco 3945 ISR G2
mgmt:10.32.146.217
sm 4/0
(internal)
ESXi
10.1.20.1
SRE
SRE External Interface
vmnic1
10.1.20.2
VSH
vmnic0wan0_0
192.168.4.10
wccp client
primary
10.1.20.3
Figure 7Adding the WAN and Primary interfaces of VSH to the network topology
Router configuration:interface GigabitEthernet0/2ip address 192.168.4.1 255.255.255.0duplex autospeed auto
!
On the VSH, configure the IP addresses and appropriate gateway IP addresses for the Primary and WAN interfaces. Follow theVSH deployment guide instructions on licensing and ESXi resource allocation for your desired VSH model.
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
11/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 10
VSH/SRE Network OptionsNote: This documentation is not intended to be a primer on WCCP. It merely lists some practical examples. For a primer onWCCP for Riverbed Steelheads, refer to the Riverbed Deployment Guide on the Riverbed Support Site athttps://support.riverbed.com/docs/appliance.htm
WCCP Using External SRE interfaceThere are a few ways to configure redirection of user traffic to VSH for optimization. In our test setup, we have a 3945 with 4Gigabit Ethernet interfaces, plus the external gigabit Ethernet interface on the SRE. We configure for the most liberal use ofinterfaces on the router: 2 for LAN/WAN traffic, 1 for management, 1 for a dedicated connection to the SRE external interface.
gi0/2
192.168.4.1
wccp router
gi0/3: mgmt10.32.146.196
Windows 2008R2E
Cisco 3945 ISR G2
mgmt:
10.32.146.217
sm 4/0
(internal)
ESXi
10.1.20.1
SRE
SRE External Interface
vmnic110.1.20.2
VSH
vmnic0/wan0_0
192.168.4.10
wccp client
primary10.1.20.3
Windows 7
test:
192.168.3.10
gi0/0
192.168.3.201
LAN routerWCCPin
gi0/1
192.168.0.201
WAN router
WCCP
in
T1 WAN
Figure 8Adding the branch network to the VSH topology
Default branch routing to WAN
Let us begin by adding the basic routing needed for the branch to get out to the WAN.
gi0/0 is our router LAN interface and gi0/1 is our WAN router interface. The LAN is a flat 192.168.3.0/24 network, and the WAN isa flat 192.168.0.0/24 network.
Router configuration:interface GigabitEthernet0/0ip address 192.168.3.201 255.255.255.0
duplex autospeed auto
https://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htm -
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
12/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 11
!interface GigabitEthernet0/1ip address 192.168.0.201 255.255.255.0duplex autospeed auto
!
On the windows machine, configure an IP address on the test network (192.168.3.0/24) and specify the gateway IP address
(192.168.3.201).
Verify from the Windows client that you can ping the gateway/LAN router interface and the WAN router interface.
Basic WCCP configuration (Router)
Continue with the WCCP configuration on the router. We will redirect all traffic coming into the router LAN and WAN interfaces tothe VSH/external interface on the SRE. The Steelhead will join WCCP group 61. The LAN and WAN interfaces will be configuredto redirect traffic coming into those interfaces to WCCP group 61.
Router configuration:ip cefip wccp 61ip wccp 62interface GigabitEthernet0/0
ip address 192.168.3.201 255.255.255.0ip wccp 61 redirect induplex autospeed auto
!interface GigabitEthernet0/1ip address 192.168.0.201 255.255.255.0ip wccp 61 redirect induplex autospeed auto
!
Note that in this lab example, weve defined WCCP service group 62 but not used it. Since this is a single Steelhead environment,in this case having one WCCP service group used is ok, because regardless of the direction of traffic for the single used servicegroup, there is only one WCCP client (Virtual Steelhead) to choose from. In our next example with multiple Steelheads, we will
use multiple service groups to load balance to two Virtual Steelheads.
Basic WCCP configuration (Steelhead)
For a Riverbed primer on WCCP, refer to the Riverbed Deployment Guide on the Riverbed Support Site athttps://support.riverbed.com/docs/appliance.htm Here is a summary of basic WCCP configuration used in this environment:Configure > Networking > Simplified Routing: Collect Mappings From: NoneConfigure > Networking > In-Path Interfaces: Set an IP address/default gateway for Inpath0_0Configure > Optimization > General Service Settings: Enable In-Path Support, Enable L4/PBR/WCCP/Interceptor Support, EnableOptimizations on Interface inpath0_0Configure > Networking > WCCP: Join appropriate WCCP service groups (a screenshot of this configuration can be seen in thedual VSH WCCP configuration further in this document)
Verify you can see the Steelhead as a WCCP client on the router (show ip wccp 61 det).Verify optimization with a remote site.
Here is our test setup incorporating a remote site:
https://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htmhttps://support.riverbed.com/docs/appliance.htm -
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
13/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 12
gi0/2
192.168.4.1
wccp router
gi0/3: mgmt10.32.146.196
Windows 2008R2E
Cisco 3945 ISR G2
mgmt:
10.32.146.217
sm 4/0
(internal)
ESXi
10.1.20.1
SRE
SRE External Interface
vmnic1
10.1.20.2
VSH
vmnic0/wan0_0
192.168.4.10
wccp client
primary
10.1.20.3
Windows 7
test:
192.168.3.10
gi0/0192.168.3.201
LAN routerWCCPin
gi0/1
192.168.0.201
WAN router
WCCP
in
SH1050H
inpath0_0:
192.168.0.105
Windows 2008R2E
test:
192.168.0.101
T1 WAN
Figure 9Adding a remote site to the topology
WCCP Using Internal MGF interface
In our next topology, we make these changes:
run 2 SREs (a model 910 and a model 900), each running VSH configure the external interface on each for management of VSH instances configure a VLAN with an IP address configure the internal MGF interface (vmnic2) on each SRE as a trunk, map this interface to the VSH WAN interface,
and configure WCCP with 2 service groups, for each of the two VSH instances
The following is a diagram of the new topology:
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
14/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 13
gi0/3: mgmt
10.32.146.196
Windows 2008R2E
Cisco 3945 ISR G2
mgmt:
10.32.146.217
sm 4/0
(internal)
ESXi
10.1.20.1
SRE
SRE External Interface
vmnic1
10.1.20.2
VSH
vmnic0/primary
10.32.146.243
wan0_0
10.1.30.10
Windows 7
test:
192.168.3.10
gi0/0
192.168.3.201
LAN router WCCPin
gi0/1
192.168.0.201
WAN router
WCCP
in
SH1050H
inpath0_0:
192.168.0.105
Windows 2008R2E
test:
192.168.0.101
T1 WAN
SRE
ESXi
VSH
SRE External Interface
vmnic0/primary
10.32.146.244
wan0_0
10.1.30.11
sm 2/0
(internal)
vmnic1
10.1.40.2
10.1.40.1
vmnic2
vmnic2
sm 4/1
(internal, trunk)
sm 2/1
(internal, trunk)
VLAN1
10.1.30.1
WCCP router
In this diagram, the red pathrepresents a management network. We use one of the Gigabit ports on the router for managementas well as the external interfaces on the SRE (to manage the Steelheads). Management of the ESXi instances is via the internalSRE interface and tied to the SMX/0 interface. This interface is not recommended for user data flow.
The green pathrepresents the network path for the customer. On the router, WCCP redirect commands have been applied to thelan and wan interfaces of the router, which are Gi0/0 and Gi0/1, respectively.
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
15/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 14
In this deployment, we SM X/1(mapped to vmnic2, on ESXi) is configured as a trunk to VLAN1. IP addresses cannot be tied tothe SM X/1 interfaces. Each VSH WAN interface uses the IP address of VLAN1 as their gateway and WCCP router.
Router Configuration
ip wccp 61ip wccp 62
interface GigabitEthernet0/0description $ETH-LAN$$ETH-SW-LAUNCH$$INTF-INFO-GE 0/0$$ES_LAN$ip address 192.168.3.201 255.255.255.0ip wccp 61 redirect induplex autospeed auto!interface GigabitEthernet0/1ip address 192.168.0.201 255.255.255.0ip wccp 62 redirect induplex autospeed auto!
interface GigabitEthernet0/3description mgmtip address 10.32.146.196 255.255.255.0duplex autospeed auto!interface SM2/0ip address 10.1.40.1 255.255.255.0service-module ip address 10.1.40.2 255.255.255.0!Application: VMware ESXi 4.1.0 build-348481 running on SREservice-module ip default-gateway 10.1.40.1
!interface SM2/1description Internal switch interface connected to Service Moduleswitchport mode trunkno ip address!interface SM4/0ip address 10.1.20.1 255.255.255.0service-module ip address 10.1.20.2 255.255.255.0!Application: VMware ESXi 5.0.0 build-474610 running on SREservice-module ip default-gateway 10.1.20.1!interface SM4/1description Internal switch interface connected to Service Module
switchport mode trunkno ip address!interface Vlan1ip address 10.1.30.1 255.255.255.0ip wccp redirect exclude in!
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
16/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 15
The following is the configuration for joining WCCP Service Groups 61 and 62, with 61 expanded:
When configuring WCCP for more than one VSH, make sure to configure Connection Forwarding on each VSH instance. Thisallows the Steelheads to communicate to make sure each Steelhead gets the proper amount of WCCP bucket allocation (for theHash assignment scheme).
On each VSH instance, go to Configure > Networking > Connection Forwarding, and add each other VSH inpath IP as a neighbor.Enable Connection Forwarding. Enable In-path Neighbor Failure.
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
17/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
2012 Riverbed Technology. All rights reserved. 16
The following is an example screenshot of Connection Forwarding UI on the SRE 900 configured with the VSH instance on theother SRE (910) as a Neighbor:
Other Redirection Options
Main options: WCCP, Policy Based Routing (PBR), Interceptor, or Server-Side Out of Path to Primary Router on a stick single router interface, using subinterfaces then applying a redirection method like WCCP Active/Standby failover with 2 VSH instances: configure one VSH with a WCCP weight of 0.
Remember, do not use the management network (vmnic1) for user traffic or optimization, to reduce router load.
Recommended VSH model and SRE combinations
Riverbed supports the following combinations of software and hardware for this solution:
Platform Disk Configuration RAMMaximum VSH
ModelRiOS
SRE900/910 RAID1 8GB V1050H 7.0.0+, 6.5.4+
SRE900/910 RAID1 4GB V1050M 7.0.0+, 6.5.4+
SRE700/710 Single disk 4GB V250H 7.0.0+, 6.5.4+
SRE300 NOT SUPPORTED
300 model SRE: as this platform has no hard drive, this is platform is unsupported for VSH.
700/710 model SRE: (Core 2 solo CPU): as this platform has a single core CPU it only supports a V250L/M/H. This platform onlyhas 4GB of RAM.
900/910 model SRE: (Core2 duo CPU): as this platform has a dual core CPU, the highest supported model is a V1050H. This
-
7/22/2019 Riverbed Virtual Steelhead on Cisco SRE/ISR G2
18/18
RIVERBED VIRTUAL STEELHEAD ON CISCO ISR/G2
platform has 4 or 8GB of RAM. Since there is a RAM overhead for ESXi, 8GB is required to run the V1050H.
Note that ESXi will allow you to configure a VM with more memory than the SRE physically has. For example, an SRE with 4GBof RAM will consume some of that RAM for ESXi itself. This leaves less than 4GB available for a V1050H VSH. However, ESXiwill allow you to allocate 4GB to the VM. Doing this will allow the VM to run, and performance may seem good at first. But whenVSH attempts to utilize all 4GB of RAM, there is likely to be performance issues as ESXi substitutes slower disk for solid-stateRAM. For this reason, allocating more RAM to a VSH than the SRE has is a Riverbed unsupported configuration.
About RiverbedRiverbed delivers performance for the globally connected enterprise. With Riverbed, enterprises can successfully and intelligentlyimplement strategic initiatives such as virtualization, consolidation, cloud computing, and disaster recovery without fear ofcompromising performance. By giving enterprises the platform they need to understand, optimize and consolidate their IT,Riverbed helps enterprises to build a fast, fluid and dynamic IT architecture that aligns with the business needs of theorganization. Additional information about Riverbed (NASDAQ: RVBD) is available at www.riverbed.com.
2012 Riverbed Technology. All rights reserved.Riverbed, Cloud Steelhead, Granite, Interceptor, RiOS, Steelhead, Think Fast, Virtual Steelhead, CSA, Mazu, Cascade, Cascade Pilot, Shark, AirPcap, Skipware, TurboCap, WinPcap, Wireshark, and Stingray are trademarks or registered trademarks of Riverbed Technology, Inc. in the United States and other countries. Riverbed and any Riverbed
product or service name or logo used herein are trademarks of Riverbed Technology. All other trademarks used herein belong totheir respective owners. The trademarks and logos displayed herein cannot be used without the prior written consent of RiverbedTechnology or their respective owners.
Cisco is a registered trademark of Cisco Systems, Inc. and its affiliates in the United States and in other countries.
Microsoft is a registered trademark of Microsoft Corporation and its affiliates in the United States and in other countries.
VMware is a registered trademark of VMware, Inc. and its affiliates in the United States and in other countries.
Riverbed Technology, Inc.199 Fremont StreetSan Francisco, CA 94105
el: (415) 247-8800www.riverbed.com
Riverbed Technology Ltd.One Thames ValleyWokingham Road, Level 2Bracknell. RG42 1NGUnited Kingdom
el: +44 1344 31 7100
Riverbed Technology Pte. Ltd.391A Orchard Road #22-06/10Ngee Ann City Tower ASingapore 238873
el: +65 6508-7400
Riverbed Technology K.K.Shiba-Koen Plaza Building 9F3-6-9, Shiba, Minato-ku
okyo, Japan 105-0014el: +81 3 5419 1990
http://www.riverbed.com/http://www.riverbed.com/http://www.riverbed.com/