![Page 1: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/1.jpg)
Results of the first BBA testsat FERMI@Elettra, Trieste
A. Latina for the CERN BBA Team
Thanks to Simone Di Mitri, Eduardo Ferrari, Giulio Gaio (Elettra)
CLIC Beam Physics Meeting – May 28, 2014
![Page 2: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/2.jpg)
2
Plan of the Elettra Laboratory
![Page 3: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/3.jpg)
3
FERMI electron beamlines
Linac energy: from 100 MeV to ~1.2 GeVBunch charge: 800 pCBunch length: from 1.5 mm to 60 micron 10 Hz bunch repetition rateEmittance at gun: ~1.2 mm mrad
![Page 4: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/4.jpg)
4
FERMI linacs
![Page 5: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/5.jpg)
5
The Fermi control room
![Page 6: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/6.jpg)
6
BBA parameters• 27 X correctors• 27 Y correctors• 30 BPMs
• 1.5 betatron oscillations• Effective bpm resolution = 5 - 10 micron• 10 Hz repetition rate• SysID time required:
– About 3 minutes to measure 1 response matrix (can be reduced to 30 seconds, with deeper integration in their control system)
Measured horizontal orbit response matrix
![Page 7: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/7.jpg)
7
Orbit correction – 1:1
• First test of orbit correction:– Excited an oscillation – BBA algorithm is able to cancel it
Used 18 singular values in each axis (out of 27)
![Page 8: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/8.jpg)
8
Emittance before BBAat the end of L4
HV
![Page 9: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/9.jpg)
9
1:1 + DFS
The dispersion was measured reducing the amplitude of klystron 2 to 98% of its nominal value
This operation occurs in 1 cycle @ 10 Hz
Weight for DFS = 7 (tuned for ~10 micron BPM resolution)
![Page 10: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/10.jpg)
10
![Page 11: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/11.jpg)
11Vertical dispersion reduced by a factor ~40 ! Horizontal dispersion by factor ˜4 (!)
![Page 12: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/12.jpg)
12
Emittance measurement after DFS
Horizontal emittance from 4.21 mm mrad to 3.30 mm mrad. Vertical emittance wasn’t very good though : we had many klystron failures / the machine was drifting away
![Page 13: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/13.jpg)
13
1:1 + WFS
The wakefields were measured by changing the bunch charge to 650 pC(tests with 900 pC were foreseen, but there was not time for performing them)
Changing the charge takes about 10 seconds (time for charge feedback to converge)
Weight for WFS = 7-20 (tuned for ~10 micron BPM resolution)
![Page 14: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/14.jpg)
14
Horizontal and vertical beam sizes during WFS
WFS !
![Page 15: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/15.jpg)
15
Horizontal and vertical beam sizes during WFS
WFS !
![Page 16: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/16.jpg)
16
1:1 + DFS + WFS
![Page 17: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/17.jpg)
17
Emittance measurement after1:1 + DFS + WFS
HV
![Page 18: Results of the first BBA tests at FERMI@Elettra , Trieste](https://reader034.vdocuments.us/reader034/viewer/2022051517/56815031550346895dbe2b48/html5/thumbnails/18.jpg)
18
Conclusions
• Looks like an ideal machine for tests– Very fast control system– Excellent diagnostics
• Debug – debug – debug. Only three hours of effective beam-time
• Everything worked really well. Emittance (H; V):– Before correction: 4.31 mm mrad; 3.21 mm mrad– After DFS: 3.30 mm mrad; -– After DFS+WFS: 2.75 mm mrad; 2.57 mm mrad
• Future– Fully explore the the space of parameters: e.g.
• 1 axis at time | both axes decoupled | both axes coupled• DFS weight scan• WFS weight scan• Dependence of the result on the number of singular values
– Tests of on-line parasitic DFS / WFS ?