The World is Changing
2
§ Healthcare providers are focused on reducing costs through energy efficiency
§ Grid reliability is in question § Natural disasters increase need for long term back-up power,
heating and cooling solutions
![Page 3: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/3.jpg)
Customer-Driven Solutions
3
We want to save on energy costs.
We need reliable power.
We want to be clean and green.
We want energy independence.
Solutions for Crucial Social,
Economic & Environmental
Needs
![Page 4: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/4.jpg)
• Founded 1988 − Commercial launch in 1998 • Public Company on NASDAQ: CPST • World Leader in Microturbines • Headquarters and manufacturing plants in California • Sales and/or service centers in China, Mexico,
Singapore, South America, the United Kingdom, and the United States
• Over 95 Distribution Partners • Over 9,000 units shipped
worldwide with more than 60 million operating hours
Capstone Turbine Corporation
4
![Page 5: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/5.jpg)
What Is CHP? • An Integrated Heating Cooling and Electric Power
System • Located Onsite or Near a Building/Facility • Supplies a Portion of the Total Electric Load • Recovers the Waste Heat from Generating
Electricity to Provide the Facility with: – Space Heating/Hot Water/Steam – Space Cooling – Dehumidification – Heat for Processes (such as sterilization or cooking)
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 5
![Page 6: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/6.jpg)
Reason #1 • Combined Heat and Power (CHP) Saves
Money by Increasing Efficiency
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 6
![Page 7: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/7.jpg)
Typical CHP Paybacks
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 7
![Page 8: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/8.jpg)
Reason #2 • CHP can be simple, modular, small, quiet
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 8
![Page 9: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/9.jpg)
Integrated CHP Solution
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 9
Heat Recovery Module (HRM)
![Page 10: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/10.jpg)
Reason #3 • CHP can fit with your environmental goals
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 10
Category Reduction vs Traditional (1)
Greenhouse Gas (CO2) 28% Criteria Pollutants (NOx) 94% Energy (Fuel in MMBTU/year) 29% Equivalent Cars Removed (2) 575 (1) Based on 50% Heating/50% Cooling. Capstone MT heat recovery uses double effect
absorption chiller for cooling. Traditional assumes average US Power Plant (Source: EPA) for electricity, electric chiller with COP of 3, and 80% efficient boiler.
(2) Assumes 1MW project operating 8,500 hours per year. US EPA data for “equivalent” car emissions and fuel consumption.
![Page 11: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/11.jpg)
EPA Recognition
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 11
![Page 12: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/12.jpg)
Reason #4 • CHP can provide backup power
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 12
ENERGY How Natural Gas Kept Some Spots Bright and Warm as Sandy Blasted New York City By ANDREW C. REVKIN NOVEMBER 5, 2012 6:11 PM
![Page 13: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/13.jpg)
Severe Weather • Caused 675 power
outages in USA since 2003
• Cost $18-33 billion per year
• Account for over 70% of all power outages today, compared to 25% before 1980
• 70% of grid transformers and transmission lines are over 25 years old
Source: Accuweather
Source: CBC
![Page 14: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/14.jpg)
Reason #5 • Financing and Incentives Exist for CHP
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 14
Dell Children’s Medical Center of Central Texas is selling excess electricity back to the grid from their CHP system through a net metering arrangement New York Presbyterian gets natural gas at a preferred cogeneration rate from ConEd
![Page 15: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/15.jpg)
Reason #6 • Over 300 Hospitals in U.S. Have a CHP
System • Resources Saved Can Be Reinvested in
Improving Patient Care
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 15
![Page 16: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/16.jpg)
16
Case Study: Kaiser Vacaville • Medical Center Combined Heat and Power
– 12 Capstone C65 to generate 750 kW – Commissioned 2009
• Facility Quick Facts – 580,000 sq. ft. – facility average load 1MW – Electricity offsets base load, heat offsets boiler
• Benefits – NOx emissions reduced by 72 tons a year – CO2 emissions reduced by 1,741 tons per year – Payback 2.5 years
Annual Energy Bill savings $450,000 / year
![Page 17: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/17.jpg)
Why Microturbine CHP?
• Lowers operating costs • High reliability >98% • Low total cost of ownership • Low emissions • Low noise
PROPRIETARY AND CONFIDENTIAL Capstone Turbine Corporation 17
![Page 18: Reliable Onsite Power Using Microturbines | Five Reasons You Should Be Creating Energy](https://reader031.vdocuments.us/reader031/viewer/2022030307/58e8d0881a28abb3398b5533/html5/thumbnails/18.jpg)
Contact Info
18