Transcript
Page 1: (RECIRCULATION / NEGATIVE PRESSURE) ADVANCED HEPA FILTRATION - Quatro Air … · 2021. 3. 2. · CONTAMINATED AIR CLEAN AIR EXHAUST AF1000-MNP (RECIRCULATION / NEGATIVE PRESSURE)

· High volumetric �ow rate· Whisper quiet operation· Filtration system: pre�lter, high capacity and HEPA �lter· Intelligent controls, digital speed control , audible and visual alarms

CONTAMINATED AIR

CLEAN AIREXHAUST

AF1000-MNP(RECIRCULATION / NEGATIVE PRESSURE)

ADVANCED HEPA FILTRATIONFor healthcare facilities, isolation rooms and infection control areas

Quatro reserves the right to modify any specifications, at any time without prior notice.

STA

ND

ARD

CO

NFI

GU

RATI

ON

PRO

DU

CT

HIG

HLI

GH

TS

Air Flow: Nominal 500 CFM / 850 m3/hVoltage: 120V (2A) or 230V (1A)Dimensions: 56"H x 16"W x 22"D / 132cm x 40cm x 56cmFiltration: 2” Pre-filter MERV10 12” High capacity pleated filter MERV12 6” Medical grade HEPA filter 99.995% (down to 0.3 µm) Optional: chemical filter (up to 50 lbs/23 kg)Inlet: Bottom inletDischarge: 6” Discharge collar (4”, 8” optional)Sound Level: Whisper quiet, 54 dBAControls: Digital speed control, audible and visual alarms OPTIONAL: Remote ON/OFF and communication

3087792CONFORMS TO:UL STD 507CERTIFIED TO:CSA STD C22.2 NO 113

AIR TECHNOLOGIES INC.1.877.978.2876 · quatroair.com

8‘ �exible hose,and additional 6” collar

NEGATIVEAIR FLOW

F007 Prefilter F357 HEPA FilterF015 Pleated Filter

MULTI-STAGE FILTRATION SYSTEMCLEAN AIR is the key factor in creating a safe environment for patients and staffThe hospital and healthcare environments require high quality air management solutions to protect patients and staff against infections and occupational diseases.Our units offer proven air purification solutions against airborne contaminants, chemicals and odors.

Top Related