Transcript
Page 1: Real Thermal Solutions by Experiments - Long Win€¦ · Real Thermal Solutions by Experiments Since 1985, we are devoted to research, design, manufacture and service for scientific

RQ Curve - Thermal resistance (R) and the relationship between P and Q

Fan & System Performance Rating

Thermal Conductivity Measurement

Real Thermal Solutions by ExperimentsReal Thermal Solutions by Experiments

Since 1985, we are devoted to research, design, manufacture and service for scientific instruments about thermal management, solid & fluid mechanic and educational fields, especially owns a leading position on research & measurement products for electronic cooling market.

More than 100 kinds of self-development apparatus are in our lab with the area of 18000 sq. ft. in Taiwan. Welcome to visit and have a test.

Long Win Science and Technology Corporation http://www.longwin.comHead office in TaiwanTEL: +886 3 464 [email protected]

Branch office in USATEL: +1 925 683 [email protected]

Static Pressure (P) v.s. Air Flow Rate (Q)

0

10

20

30

40

50

60

70

80

90

100

110

120

0 5 10 15 20 25 30 35 40 45 50

Air Flow Rate, Q (CFM)

Stat

ic P

ress

ure,

P (m

mA

q)

PQ Curve - The fan performance curve with static pressure (P) and air flow rate (Q)

System Impedance Curve

0

1

2

3

4

5

6

7

8

9

10

11

12

0 1 2 3 4 5 6 7 8 9 10 11 12

Air Flow Rate, Q (CFM)

Stat

ic P

ress

ure,

P (m

mA

q)

SRC Curve - System resistance measurement for PC, NB, and server

Heat Flux Method:Based on Fourier’s Law of heat conduction & ASTM D 5470-06 Standard

Model: For homogeneous materials with low K valueEX: Thermal pad and grease

Thermal Resistance v.s. Thickness

0.0

0.5

1.0

1.5

2.0

2.5

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

Thickness, Th (mm)

Ther

mal

Res

ista

nce,

R (°

C/W

)

LW-9389LW-9389 Model:For homogeneous materials with high K valueEX: Metal and alloy plates

Heat Pulse Method:For transient K measurement

Temperature v.s. Distance at different time

25

30

35

40

45

50

0 1 2 3 4 5 6

Distance from the heating center (mm)Te

mpe

ratu

re, T

(°C

)

LW-9286LW-9286 Model: For in-plane thermal conductivity measurementEX: Graphite heat spreaders

Angstrom Method:By scanning harmonic of temperature waves

Angstrom Method for Copper

10

12

14

16

18

20

22

24

26

28

0 40 80 120 160 200

Time (sec)

Tem

pera

ture

, T (°

C)

LW-9514LW-9514

Understanding scientific principles through easy operationsSuitable for academic laboratory in universities

Educational Facilities for Engineering►Solid mechanics ►Fluid mechanics ►Thermodynamics►Solid mechanics ►Fluid mechanics ►Thermodynamics

Meet AMCA 210-07; Flow rate range: 0.2~30000 CFM AMCA 210 Wind TunnelsLW-9015 seriesLW-9015 series

Temperature range: Ambient+3 ~ 90°CRelative humidity: 40 ~ 95%Temperature deviation: < ± 2°CVarious of sizes: 50×50×62 cm ~ 200×110×180 cm

Simulation of the Authentic EnvironmentNatural Convection ChamberLW-9022 seriesLW-9022 series

LW-9383LW-9383Modified JEDEC JESD 51-1 Standard of the diode arrayFast data acquisition rate: 200 kHzAdjust forward voltage, sensing current, power, ambient temp. etc.

LED Tj & Rjc Measurement

Thermal Resistance (R) v.s. Air Flow Rate (Q)

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0 25 50 75 100 125 150 175

Air Flow Rate, Q (CFM)

Ther

mal

Res

ista

nce,

R (°

C/W

)

0

5

10

15

20

25

30

35

Pres

sure

, P (m

mA

q)

In 2011, Long Win is planning to build our own

sales office and service lab in USA.

We sincerely welcome anyone who interests our products and wants to be

our sales partner.

Agencies Wanted

C

M

Y

CM

MY

CY

CMY

K

LonGwin-7.5x9.625.pdf 2011/3/4 上午 11:10:02

Top Related