Outputs
Radio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non StandardMaintenance
A50023-X4005-A2-4-7619
-
8/12/2019 Rc_obr7.0 Output Manual Oml
2/54
2 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of theparts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal injury or in prop-erty damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to complywith the applicable safety standards.
The same text in German:Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung. Einige Teileknnen auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungen undSachschden fhren.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertesPersonal die Anlagen installiert undwartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Gertemssen die zutreffenden Sicherheitsbestimmungen erfllen.
Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for theirown purposes could violate the rights of their owners.
Copyright (C) Siemens AG 2003-2003.
Issued by the Information and Communication Networks Group
Hofmannstrae 51
D-81359 Mnchen
Technical modifications possible.
Technical specifications and features are binding only insofar as
they are specifically and expressly agreed upon in a written contract.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
3/54
A50023-X4005-A2-4-7619 3
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
Issues
Change indications (Ind.):
N = new; G = modified; 0 = deleted;
Document Title Page(s) Issue/Ind.
MMN:UMR 3.0 . . . . . . . . 1... 54 4/ N
This document consists of a total of 54 Pages.
Issue History
IssueNumber
Date of Is-sue
Reason for Update
Draft1 Jan. 2003 First Draft release.
1
2
3
4 Dec. 2003 FEKAT correction CU9965
-
8/12/2019 Rc_obr7.0 Output Manual Oml
4/54
4 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
-
8/12/2019 Rc_obr7.0 Output Manual Oml
5/54
-
8/12/2019 Rc_obr7.0 Output Manual Oml
6/54
6 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
3.5 unauthorizedAccessAttempt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
3.6 sbsOimFileTransferControl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
3.7 outOfHoursActivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.8 authenticationFailure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4.1 Specific Problems for the Alarm List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
-
8/12/2019 Rc_obr7.0 Output Manual Oml
7/54
A50023-X4005-A2-4-7619 7
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
1 IntroductionThe goal of this manual is to describe all alarms and system informations which can gen-
erated by the Radio Commander.
The software attempts to provide a precise error description for each alarm containing
all informations for the operator and manufacturer for rapid localization, investigation
and elimination of the fault. There is no relation between the number of described faults
and their frequency of occurrence in the system.
This manual is organized according to the error ID's.
Error ceased messages clears all alarms for a certain probable cause of one object.
Error ID:
Shows the Error ID for the notification
MOC:Identifies the managed object class of the fault or error.
Version:
Format not yet defined.
Error information:
This gives a detailed overview about the occurred error:
Values:
communicationAlarm
environmentalAlarmequipmentAlarm
qualityOfServiceAlarm
processingErrorAlarm
Identifies the probable cause of the fault or error. The probable cause is taken out of
a predefined set of values defined for each alarm type.
This is a short description of the error.
According to the CCITT Rec. X.733 all alarm notifications produced in switching sys-
tems have to be classified concerning the severity of their impact on the NE's func-
tionality.
Values: indeterminate, critical, major, minor, warning
Gives information about the reached threshold.
Currently not used.
This field will be used to give reason for the occurred error/event. According to
CCITT X.733 this part, when present, allows a free form text description to be re-
ported.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
8/54
8 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
Immediate defense action:
This section describes the defense action accomplished by the software every time the
particular Failure Event occurs. The defense action is accomplished to attempt to solve
or at least to overcome the problem.n.a. is reported if no defense action is associated to the Failure Event.
Proposed repair actions:
Describes the actions the operator must perform to attempt to solve the problem.
Every time that a diagnostic on a faulty object fails, the operator has to replace the faulty
module (specified in the Test Report) following the procedure described in the according
maintenance manual.
Error description:
Concise description of the probable cause of the error.
1.1 Abbreviations
Abbr. Meaning
BSC Base Station Controller
BSS Base Station Subsystems
CLI Command Line Interface
GUI Graphical User Interface
LAN Local Area NetworkLMT Local Maintenance Terminal
(m) Value is mandatory
MOC Managed Object Class
MSC Mobile Services Switching Center
n.a. Not available
NE Network Element
(o) Value is optional
OMP Operating and Maintenance Processor
OMT Operating and Maintenance Terminal
PCM Puls Code Modulation
RC Radio Commander
SMLC Serving Mobile Location Center
WAN Wide Area Network
Tab. 1.1 Abbreviations
-
8/12/2019 Rc_obr7.0 Output Manual Oml
9/54
A50023-X4005-A2-4-7619 9
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2 Alarms
2.1 Time of Network Element out of sync with OMC (500)Error ID: 500
MOC: DNODEB, DRNC, DBSS
Version: n.a.
Error information: equipmentAlarm
gsmClockSynchronisa-tionProblem
Time of Network Elementout of sync with OMC
warning
(o)
(o)
reason: NE time is out ofsync with RCtime, NEtimeset. Date and Time:outOfSyncBy:
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
No action required
Error description: The error is generated in case the BSC, RNC or NodeN clockis not synchronized with the OMP clock.Periodic time check must be activated explicitly from GUI orCLI session.At the configured time intervals, OMP checks whether theclock of each NE connected is synchronized with the OMP. Ifthe difference is bigger than a predefined threshold, then date& time of the BSC, RNC or NodeB are set and this error is gen-erated.Note: at the time the O-link, Ift-R or Itf B connection is estab-lished, date & time of the BSC, RNC or NodeB are set withoutgenerating an alarm, even if the threshold was exceeded
-
8/12/2019 Rc_obr7.0 Output Manual Oml
10/54
10 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.2 SW Recovery Action (501)
Error ID: 501
MOC: OMP, OMT
Version: n.a.
Error information: processingErrorAlarm
softwareProgramAbnormallyTer-minated
SW recovery action
warning
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
no repair action necessary - automatic recovery, take alarm asnotice
Error description: RC initiates autonomous SW recovery action
-
8/12/2019 Rc_obr7.0 Output Manual Oml
11/54
A50023-X4005-A2-4-7619 11
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.3 Disk Generic HW Error (502)
Error ID: 502
MOC: HDD
Version: n.a.
Error information: equipmentAlarm
gsmDiskProblem
Disk Generic HW Error
critical
(o)
(o)
(o)
Immediate defenseaction:
Try to make a back-up of all data.
Proposed repair ac-tions:
1.Locate the effected disk.2.Contact local SUN service or local staff to replace the faultydisk and provide the following information: Effected OMP. Type of effected disk.3.Make sure that after have replaced thedisk therelatedalarmis ceased. If the alarm after few minutes is still active contactlocal SUN service or local staff. Otherwise give hddReplace
command available on CLI/GUI.
Error description: A physical error was detected in the hard disk.The followingcases are possible:
OMP failure on disk with system software
No redundancy/mirroring, only one diskMay be that the RC stops working. Then it is not longer possi-ble to access/maintain of the RC and the connected radio sub-systems.Redundancy/mirroring, two or more disks
The system switches automatically to redundant disk. Thesystem and RC will continue working.
OMP failure on disk with RC data
No redundancy/mirroring, only one diskThe RC stops working immediately. It is not longer possible toaccess/maintain of the RC and the connected radio sub-systems.Redundancy/mirroring, two or more disksThe system switches automatically to redundant disk. Thesystem and RC will continue working.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
12/54
12 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.4 Mirror/SubMirror Failure (503)
Error ID: 503
MOC: DATAUNIT
Version: n.a.
Error information: equipmentAlarm
gsmDiskProblem
Mirror/SubMirror failure
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1. Locate the effected disk on OMP: execute metastat andmetadb SDS maintenance commands to see what is/are thespecific problem within Solstice Disk Suite Object (Mirror/Sub-mirror). See Solstice Disksuite 4.2 User's Guide for further de-tails.2. Contact local SUN service or local staff.Provide the error message and exact information from the pre-vious step.
Error description: Solstice Disk Suite Object (Mirror/Submirror) malfunction.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
13/54
A50023-X4005-A2-4-7619 13
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.5 MetaDb Failure (504)
Error ID: 504
MOC: DISKLAYOUT
Version: n.a.
Error information: equipmentAlarm
gsmDatabaseInconsistency
MetaDb failure
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.Locate the affected meta DB replicas on OMP: executemetadb SDS maintenance command to see what is/are thespecific problem within Solstice Disk Suite Object (meta DBReplicas). See Solstice Disksuite 4.2 User's Guide for furtherdetails.2.Contact local SUN service or local staff.It is necessary to reconfigure the MetaDB.Provide the error message and exact information about your
system.
Error description: Solstice Disk Suite Object (MetaDB Replica) malfunction onOMP. RC could will stop working soon.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
14/54
14 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.6 Threshold Crossed (505)
Error ID: 505
MOC: DATAUNIT
Version: n.a.
Error information: processingErrorAlarm
gsmSystem ResourcesOverload
Threshold crossed
major
(o)
(o)
(o)
Immediate defenseaction:
Do not write on this Data Unit anymore, until related alarmceases.
Proposed repair ac-tions:
1.) Perform fault clearance task T-15 Checking available diskspace to collect information.2.) Free some space on the involved data unit (for example de-lete old files) or expand the quota assigned to the involveddata unit (for example adding a new disk to the system), usinginformation collected from previous step.
Error description: The involved data unit of type equal to ufs has crossed the re-lated threshold.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
15/54
A50023-X4005-A2-4-7619 15
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.7 OMT-OMP Communication Failure (OMT) (506)
Error ID: 506
MOC: OMT
Version: n.a.
Error information: communicationsAlarm
gsmLinkFailure
OMT-OMP communication failure(OMT)
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1. Check the network cable of the OMT:Are the network cable plugs inserted correctly into the socketsat both ends?2. Check the network connection to OMT from an UNIX shellin the primary OMP with the followingcommand:ping
If the network connection is OK, the OMT will acknowledge.3. Check whether OMT is shutdown.If there is still no connection between OMT and OMP contactyour local staff.
Error description: A communication failure is detected on connection with theOMT.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
16/54
16 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.8 Disconnected BSS (507)
Error ID: 507
MOC: OLINK
Version: n.a.
Error information: communicationsAlarm
gsmLinkFailure
Disconnected BSS
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Check whether there is only one, several or all BSS resp.BSC concerned.2.) Perform fault clearance tasks T-26 Checking X.25 configu-ration, T-27 Checking X.25 link status, T-28 Tracing an X.25link, and T-32 Checking status of PCM card or T-33 Checkingstatus of HSI ports.3.) Check plugs and HSI or PCM card on the OMP using thecorresponding manuals.
4.) Check the following processes: osinetd, osimcsd,em_cmip, x25netd5.) Check failed BSC status from LMT.
Error description: The BSS is disconnected.There are three possibilities where the connection betweenBSS and OMP can be disturbed. This depends on how theBSS is connected to the OMP:- Direct link between OMP and BSS using HSI card (A)- WAN link between OMP and BSS using HSI card- PCM (nailed-up) link: connection from OMP to MSC usingSprite card (B)
- PCM (nailed-up) link: connection from MSC to BSS (C)
-
8/12/2019 Rc_obr7.0 Output Manual Oml
17/54
A50023-X4005-A2-4-7619 17
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.9 1 O-Link Down (508)
Error ID: 508
MOC: OLINK
Version: n.a.
Error information: communicationsAlarm
gsmLost Redundancy
1 O-link down
major
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Check physical connection.2.) If available check the Sprite card and Sprite port.3.) Perform fault clearance task T-26 Checking X.25 configu-ration, T-27 Checking X.25 link status, T-28 Tracing an X.25link.4.) Check osinetd process.5.) Check ftcserver.luc process.6.) Check failed BSC status from LMT.
Error description: The Olink redundancy is lost. The specified Olink is discon-nected.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
18/54
18 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.10 LAN Card Failure (509)
Error ID: 509
MOC: OMP
Version: n.a.
Error information: communicationsAlarm
gsmEquipmentFailure
LAN Card Failure
major
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Check network connections of the OMP:Are the network cable plugs inserted correctly into the socketsat both ends?If the plugs are inserted correctly this alarm means that onelan card is faulted. Then contact your local staff providing theerror message and exact information about your OMP.If the plugs aren't inserted correctly, plug them in. Note that forthis version of RC the emitted alarm will not be cleared.
Error description: On Extended Redundant OMP one lan card (or network con-nection) is faulted.OMP switched to redundant lan card and emitted this alarm toindicate this situation.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
19/54
A50023-X4005-A2-4-7619 19
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.11 Possible Fault on a HSI Communication Board (510)
Error ID: 510
MOC: HSI_CARD
Version: n.a.
Error information: communicationsAlarm
gsmEquipmentFailure
Possible Fault on a HSI Communi-cation Board
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Check plugs and HSI card on the OMP using the corre-sponding manuals.2.) Check the following processes: osinetd, osimcsd,em_cmip, x25netd3.) Perform fault clearance tasks T-26 Checking X.25 configu-ration, T-27 Checking X.25 link status, T-28 Tracing an X.25link, and T-33 Checking status of HSI ports.
4.) Contact your local staff to check the cables and the HSIcard itself using the corresponding manual. Provide the alarmnumber andmessage and exact information from the previousstep.
Error description: All OLinks which are connected to the same HSI card becamefaulty.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
20/54
20 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.12 Possible Fault on a PCM Communication Board (511)
Error ID: 511
MOC: SPRITE_CARD
Version: n.a.
Error information: communicationsAlarm
gsmEquipmentFailure
Possible Fault on a PCM Commu-nication Board
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Check plugs and PCM Card on the OMP using the corre-sponding manuals.2.) Check the following processes: osinetd, osimcsd,em_cmip, x25netd3.) Perform fault clearance tasks T-26 Checking X.25 configu-ration, T-27 Checking X.25 link status, T-28 Tracing an X.25link, and T-33 Checking status of HSI ports.
4.) Contact your local staff to check the cables and the Spritecard itself using the corresponding manual. Provide the alarmnumber and message andexact information from the previousstep.
Error description: All OLinks which are connected to the same PCM card be-came faulty.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
21/54
A50023-X4005-A2-4-7619 21
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.13 PCM Switch Failure (512)
Error ID: 512
MOC: OMP
Version: n.a.
Error information: communicationsAlarm
gsmEquipmentFailure
PCM Switch failure
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Contact your local staff to check the cables plugged in correct-ly: From OMP to PCM Switch and from PCM Switch to the net-work using the correspondent manual.
Error description: PCM Switch failure. The connection from OMP to PCM Switch(so called Selector Unit) or from PCM Switch to the network isdisturbed.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
22/54
22 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.14 External Alarm Device Failure (513)
Error ID: 513
MOC: EXT_ALARM_DEVICE
Version: n.a.
Error information: equipmentAlarm
gsmEquipmentFailure
External Alarm Device Failure
major
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1. Check the components of the alarm device panel (e.g.lamp(s), siren) using the corresponding manual.2. Check the cables whether they are plugged in correctly andinto the correct ports.
Error description: A fault occurred on External Alarm Device Panel.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
23/54
A50023-X4005-A2-4-7619 23
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.15 Log Instance Reached Warning Threshold (514)
Error ID: 514
MOC: RC_LOG
Version: n.a.
Error information: processingErrorAlarm
Storage Capacity Problem
Log instance reached warningthreshold
warning
triggeredThreshold:"SbsOim":sb-sOimCapacityAlarmThresholdobservedValue: integer (an addi-tional capacity alarm threshold ex-ceeded)
attributeId: "SbsOim":sbsOimMax-LogSizeMegaByteattributeValue: integer (max logsize of the log instance expressedin MegaByte)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Increase the size (maxLogSize parameter) of the alarmedlog instance.2.) Increase the additional threshold value of the alarmed loginstance.
Error description: An additional capacity threshold has been reached or exceed-edby the log instance.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
24/54
24 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.16 Log Instance Reached Minor Threshold (515)
Error ID: 515
MOC: RC_LOG
Version: n.a.
Error information: processingErrorAlarm
Storage Capacity Problem
Log instance reached minor thres-hold
minor
triggeredThreshold:"SbsOim":sb-sOimCapacityAlarmThresholdobservedValue: integer (mi-norThreshold or capacity alarmthreshold exceeded)
attributeId: "SbsOim":sbsOimMax-LogSizeMegaByteattributeValue: integer (max logsize of the log instance expressedin MegaByte)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Increase the size (maxLogSize parameter) of the alarmedlog instance.2.) Increase the minor threshold value of the alarmed log in-stance.
Error description: A minor capacity threshold has been reached or exceeded bythe log instance named.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
25/54
A50023-X4005-A2-4-7619 25
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.17 Log Instance Reached Major Threshold (516)
Error ID: 516
MOC: RC_LOG
Version: n.a.
Error information: processingErrorAlarm
Storage Capacity Problem
Log instance reached majorthresh-old
major
triggeredThreshold:"SbsOim":sb-sOimCapacityAlarmThresholdobservedValue: integer (ma-jorThreshold or capacity alarmthreshold exceeded)
attributeId: "SbsOim":sbsOimMax-LogSizeMegaByteattributeValue: integer (max logsize of the log instance expressedin MegaByte)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Increase the size (maxLogSize parameter) of the alarmedlog instance.2.) Increase the major threshold value of the alarmed log in-stance.
Error description: A major capacity threshold has been reached or exceeded bythe log instance named.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
26/54
26 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.18 Log Instance Reached Critical Threshold (517)
Error ID: 517
MOC: RC_LOG
Version: n.a.
Error information: processingErrorAlarm
Storage Capacity Problem
Log instance reached criticalthreshold
critical
triggeredThreshold:"SbsOim":sb-sOimCapacityAlarmThresholdobservedValue: integer (criticalTh-reshold or capacity alarm thresholdexceeded)
attributeId: "SbsOim":sbsOimMax-LogSizeMegaByteattributeValue: integer (max logsize of the log instance expressedin MegaByte)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Increase the size (maxLogSize parameter) of the alarmedlog instance.2.) Increase the critical threshold value of the alarmed log in-stance.3.) If the log full condition has been reached set the logFullAc-tion to wrap for going on writing log records by dropping theoldest ones.
Error description: A critical capacity threshold has been reached/exceeded bythe log instance or a log full condition has occurred.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
27/54
A50023-X4005-A2-4-7619 27
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.19 The Agent Has Hit Configured Threshold Level (518)
Error ID: 518
MOC: RC
Version: n.a.
Error information: processingErrorAlarm
Threshold Crossed
The agent has hit configuredthreshold level
minor
thresholdLevel: integer
(o)
The agent has hit certain thresholdlevel
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
If critical threshold was crossed, then the operator has threepossibilities:
1. Turn on automatic overload (if it was not activated yet), thenthe link to the overloaded agent will be automatically locked af-ter the critical threshold was crossed (Alternative 1)
2. Turn off automatic overload handling (if it was not deactivat-ed yet), then he has the possibility to use (Alternative 2), butbe aware, the system can be really overloaded.
3. Re-configure the overload parameters (Alternative 3), butbe aware, because the system can be really overloaded.
Error description: An agent (BSS or RNS) has crossed the pre-configuredthreshold level of events-per-agent.The overload handling is implemented in the MPA (MessageProtocol Adapter) and it offers 4 threshold levels (warning, mi-
nor, major, critical - selectable during installation or from main-tenance terminal) for check the overload situation on the linksor on the MPA itself. In overload situation one alarm is emittedwith severity for the corresponding thresholds level.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
28/54
-
8/12/2019 Rc_obr7.0 Output Manual Oml
29/54
A50023-X4005-A2-4-7619 29
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.21 B-Link Corba Disconnected (520)
Error ID: 520
MOC: ITFB
Version: n.a.
Error information: communicationsAlarm
Link Failure
B-link Corba disconnected
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Check Network connection.
Error description: n.a.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
30/54
30 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.22 R-Link CMISE Disconnected (521)
Error ID: 521
MOC: ITFR
Version: n.a.
Error information: communicationsAlarm
gsmEquipmentFailure
R-link CMISE disconnected
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Check network connections of the OMP:Are the network cable plugs inserted correctly into the socketsat both ends?If not, plug them in; the network connection will establish itselfwithin a few seconds.If the plugs are inserted correctly or network connectiondoesn't establish then contact your local staff providing the er-ror message and exact information about your OMP.
Error description: OMP has no access to the LAN ( lan card(s) or network con-nection(s) are faulted).This alarm will only appear on the OMT running on the OMP.The following scenarios can be the reason for this alarm:- complete RNC outage- restart of the RNC- FE problems on RNC- LAN problems
-
8/12/2019 Rc_obr7.0 Output Manual Oml
31/54
A50023-X4005-A2-4-7619 31
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.23 SubMirror Resyncing (522)
Error ID: 522
MOC: DATAUNIT
Version: n.a.
Error information: equipmentAlarm
gsmDiskProblem
SubMirror Resyncing
major
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
No Action.
Error description: Solstice DiskSuite Submirror is resyncing, i.e. there are datatransferred from onepart of a mirror to theother, normally afterreplacing a faulty disk. The duration of resyncing depends onthe disk capacity and the amount of stored data. It can takemore than one hour.Working with the Radio Commander is not affected.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
32/54
32 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.24 Network Unavailable (523)
Error ID: 523
MOC: OMP
Version: n.a.
Error information: communicationsAlarm
gsmEquipmentFailure
Network unavailable
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Check network connections of the OMP:2.) Are the network cable plugs inserted correctly into thesockets at both ends? If not, plug them in; the network connec-tion will establish itself within a few seconds.3.) If the plugs are inserted correctly or network connectiondoesn't establish then contact your local staff providing the er-ror message and exact information about your OMP.
Error description: OMP has no access to the LAN ( lan card(s) or network con-nection(s) are faulted).This alarm will only appear on the OMT running on the OMP.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
33/54
-
8/12/2019 Rc_obr7.0 Output Manual Oml
34/54
-
8/12/2019 Rc_obr7.0 Output Manual Oml
35/54
A50023-X4005-A2-4-7619 35
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.27 Alignment Procedure Failed (527)
Error ID: 527
MOC: sbsTrauEquipment, sbsBtsePico, sbsBtseP, sbsBtseEM, sb-sBtsE, sbs3gManagedElement, nbManagedElement,nb2ManagedElement (all alarms generate locally at RadioCommander)
Version: n.a.
Error information: processingErrorAlarm
Software Program Abnormally
Alignment Procedure Failed
warning
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Try re-aligning using commands.
Error description: An error occurred during an alignment phase
-
8/12/2019 Rc_obr7.0 Output Manual Oml
36/54
36 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.28 OMP-OMP Communication failure (OMP) (528)
Error ID: 528
MOC: OMP
Version: n.a.
Error information: communicationsAlarm
gsmLinkFailure
OMP-OMP Communication failure(OMP)
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1. Check the network cable of the OMP:Are the network cable plugs inserted correctly into the socketsat both ends?2. Check the network connection to OMP from an UNIX shellin the primary OMP with the following command:ping If the network connection is OK, the OMP will acknowledge.
3. Check whether OMP is shutdown. If there is still no connec-tion between primary OMP and another OMP contact your lo-cal staff.
Error description: A communication failure is detected on connection with otherOMP.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
37/54
A50023-X4005-A2-4-7619 37
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.29 NetViewer Server indeterminate notification (529)
Error ID: 529
MOC: OimMicrowavesEquipment
Version: n.a.
Error information: equipmentAlarm
Equipment Failure
NetViewer Server indeterminatenotification
indeterminate
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Open NetViewer to get more details on the NetViewer equip-ment state/status.
Error description: An equiment notification of indeterminate severity received.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
38/54
38 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.30 NetViewer Server critical notification (530)
Error ID: 530
MOC: OimMicrowavesEquipment
Version: n.a.
Error information: equipmentAlarm
Equipment Failure
NetViewer Server critical notifica-tion
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Open NetViewer to get more details on the NetViewer equip-ment state/status.
Error description: An equiment notification of critical severity received.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
39/54
A50023-X4005-A2-4-7619 39
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.31 NetViewer Server major notification (531)
Error ID: 531
MOC: OimMicrowavesEquipment
Version: n.a.
Error information: equipmentAlarm
Equipment Failure
NetViewer Server major notification
major
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Open NetViewer to get more details on the NetViewer equip-ment state/status.
Error description: An equiment notification of major severity received.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
40/54
40 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.32 NetViewer Server minor notification (532)
Error ID: 532
MOC: OimMicrowavesEquipment
Version: n.a.
Error information: equipmentAlarm
Equipment Failure
NetViewer Server minor notifica-tion)
minor
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Open NetViewer to get more details on the NetViewer equip-ment state/status.
Error description: An equiment notification of minor severity received.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
41/54
A50023-X4005-A2-4-7619 41
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.33 NetViewer Server warning notification (533)
Error ID: 533
MOC: OimMicrowavesEquipment
Version: n.a.
Error information: equipmentAlarm
Equipment Failure
NetViewer Server warning notifica-tion
warning
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
Open NetViewer to get more details on the NetViewer equip-ment state/status.
Error description: An equiment notification of warning severity received.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
42/54
-
8/12/2019 Rc_obr7.0 Output Manual Oml
43/54
A50023-X4005-A2-4-7619 43
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
2.35 NetViewer Connection Down (535)
Error ID: 535
MOC: OimNetviewerLink
Version: n.a.
Error information: communicationsAlarm
LinkFailure
NetViewer Connection Down
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1.) Check network connections of the OMP:Are the network cable plugs inserted correctly into the socketsat both ends?2.) If theplugs are inserted correctly this alarm means that onelan card is faulted. Then contact your local staff providing theerror message and exact information about your OMP. If theplugs aren't inserted correctly, plug them in. Note that for thisversion of RC the emitted alarm will not be cleared.
Error description: The Netviewer is disconnected.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
44/54
44 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
2.36 Local SMLC state file does not exist! (536)
Error ID: 536
MOC: OimSmlc
Version: n.a.
Error information: communicationsAlarm
LinkFailure
Local SMLC state file does not ex-ist
critical
(o)
(o)
(o)
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
1. Check Network connection between RC and SMLC serverAre the cable plugs inserted correctly into the sockets at bothends?2. Check the FTP script, which is responsible for the file trans-fer.
Error description: The RC can not find/open the local SMLC state file.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
45/54
A50023-X4005-A2-4-7619 45
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
3 Notifications
3.1 serviceResponse (RC_LOG)
3.2 serviceResponse (SbsOcm:session)
Error ID: n.a.
MOC: RC_LOG
Version: n.a.
Error information: serviceReport
(m) serviceResponse
(o) the following:
SeeLogs on security event log in-stance
delete log records
(m) "DateAndTime"
(m) "RC user login name"
(m) "Hostname of OMT"
(m) "Number of OMT session"
(m) "Display of OMT session"
(o) "The affected RC user login
name"
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
n.a.
Error description: A security audit trail report as described in X.740 is given.
Error ID: n.a.
MOC: "SbsOcm":session
Version: n.a.
Error information: serviceReport
(m) serviceResponse
(o) the following:
-
8/12/2019 Rc_obr7.0 Output Manual Oml
46/54
-
8/12/2019 Rc_obr7.0 Output Manual Oml
47/54
A50023-X4005-A2-4-7619 47
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
3.4 serviceFailure (SbsOcm:session)
Error information: serviceReport
(m) serviceFailure
(o) the following:
SeeLogs on security event log in-stance
delete log records
(m) "DateAndTime"
(m) "RC user login name"
(m) "Hostname of OMT"
(m) "Number of OMT session"
(m) "Display of OMT session" (o) "The affected RC user login
name"
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
n.a.
Error description: A security audit trail report as described in X.740 is given.
Error ID: n.a.
MOC: "SbsOcm":session
Version: n.a.
Error information: serviceReport
(m) serviceFailure
(o) the following:
(m) create User Profile
delete User Profile
set User Profile
import Security Data
export Security Data
import Password Dictionary
export Password Dictionary
delete Password Dictionary
abort User Sessionchange Own Password
-
8/12/2019 Rc_obr7.0 Output Manual Oml
48/54
48 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
change System Password
abort Unix Session
RC login
RC logoutSeeLogs on security event log in-stance
delete log records
reset Failed Login Counter
set Global Settings
lock Display
unlock Display
create Authorization Profile
delete Authorization Profile
set Authorization Profile
create Subprofile
delete Subprofile
set Subprofile
(m) "DateAndTime"
(m) "RC user login name"
(m) "Hostname of OMT"
(m) "Number of OMT session"
(m) "Display of OMT session"
(o) "The affected RC user loginname"
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
n.a.
Error description: A security audit trail report as described in X.740 is given.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
49/54
A50023-X4005-A2-4-7619 49
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
3.5 unauthorizedAccessAttempt
Error ID: n.a.
MOC: "SbsOim":sbsOimAuthProfile
Version: n.a.
Error information: securityServiceOrMechanismVio-lation
(m) unauthorizedAccessAttempt
(m) warning
(m) RC
(m) "RC user login name"
(m) RC (o) the following:
(m) unauthorized entered CLIcommand
(m) "DateAndTime"
(m) "RC user login name"
(m) "Hostname of OMT"
(m) "Number of OMT session"
(m) "Display of OMT session"
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
n.a.
Error description: A security service or mechanism violation as described inX.736 occurred.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
50/54
50 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
3.6 sbsOimFileTransferControl
Error ID: n.a.
MOC: "SbsOim":sbsOimFileTransferControl
Version: n.a.
Error information: "SbsOim":SbsUploadInfoType. Itdescribes the event type (startUp-load, endUpload, endConversion)which notification is related to.
The transfer identifier assigned byRC to each upload procedure.
The path name of the file uploaded.
The result of the upload (success,aborted, failed, none).
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
n.a.
Error description: This notification is used to inform the begin and the end of anupload regarding a file of measures.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
51/54
A50023-X4005-A2-4-7619 51
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
3.7 outOfHoursActivity
Error ID: n.a.
MOC: "SbsOim":sbsOimUserProfile
Version: n.a.
Error information: timeDomainViolation
(m) outOfHoursActivity
(m) warning
(m) RC
(m) "RC user login name"
(m) RC
(o) the following:
(m)command not in allowed time re-strictions
(m) "DateAndTime"
(m) "RC user login name"
(m) "Hostname of OMT"
(m) "Number of OMT session"
(m) "Display of OMT session"
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
n.a.
Error description: A security service or mechanism violation as described inX.736 occurred.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
52/54
52 A50023-X4005-A2-4-7619
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
3.8 authenticationFailure
Error ID: n.a.
MOC: "SbsOcm":session
Version: n.a.
Error information: securityServiceOrMechanismVio-lation
(m) authenticationFailure
(m) warning
(m) RC
(m) "RC user login name"
(m) RC (o) the following:
(m) RC login failed
RC login failed: OMT unknown
RC login failed: OMT has inappro-priate type
RC login failed: OMT not unlocked
RC login failed: Display host un-known
RC login failed: Display host not
unlockedRC login failed: Wrong password
RC login failed: Password expired
RC login failed: Out of allowed timeperiod
RC login failed: Invalid Unix userfor RC operator
RC login failed: RC operator ac-count blocked
(m) "DateAndTime"
(m) "RC user login name"
(m) "Hostname of OMT"
(m) "Number of OMT session"
(m) "Display of OMT session"
Immediate defenseaction:
n.a.
Proposed repair ac-tions:
n.a.
Error description: A security service or mechanism violation as described inX.736 occurred.
-
8/12/2019 Rc_obr7.0 Output Manual Oml
53/54
A50023-X4005-A2-4-7619 53
OutputsRadio Commander BR 7.0 / UMR 3.0
Output Manual OML:Non Standard Maintenance
4 Appendix
4.1 Specific Problems for the Alarm List
Error ID Specific Problems
502 Disk Generic HW Error
503 Mirror/SubMirror Failure
504 MetaDb Failure
505 Threshold crossed
506 OMT-OMP communication failure (OMT)
507 Disconnected BSS
508 1 O-Link down
509 LAN Card Failure
510 Possible Fault on a HSI Communication Board
511 Possible Fault on a PCM Communication Board
512 PCM Switch failure
513 External Alarm Device Failure
515 Log instance reached minor threshold
516 Log instance reached major threshold
517 Log instance reached critical threshold
518 The agent has hit configured threshold level
519 The MPA has hit configured threshold level
520 B-link Corba disconnected
521 R-link CMISE disconnected
522 Sub Mirror Resyncing
523 Network unavailable
524 The nbManagedElementId received doesn't match the NodeB configura-tion within RC
525 SubMirror failure
528 OMP-OMP Communication failure (OMP)
529 NetViewer Server indeterminate notification
530 NetViewer Server critical notification
531 NetViewer Server major notification
532 NetViewer Server minor notification
535 NetViewer Connection Down
Tab. 4.1 Specific Problems for the Alarm List in the GUI (without warnings)
-
8/12/2019 Rc_obr7.0 Output Manual Oml
54/54
Output Manual OML:Non Standard Maintenance OutputsRadio Commander BR 7.0 / UMR 3.0
536 Local SMLC state file does not exist!
Error ID Specific Problems
Tab. 4.1 Specific Problems for the Alarm List in the GUI (without warnings)