This phase shifter is ideal for relay testing in situations where current, voltage and phase angle must be varied
independently.
RAGNAR extends the application range of Programma's popular relay testing units SVERKER 750 and
SVERKER 650. When RAGNAR is used with either of these, you can test both directional overcurrent protections
and impedance protections.
The relay testing unit's variable current passes through RAGNAR, where it provides an accurate voltage phase-
angle reference. The voltage can then be varied up to 105 V, and the phase angle can be varied from 0° to 360°.
You set the voltage and phase angle easily using two dials on RAGNAR, and your settings appear instantly on
built-in displays in large easy-to-read numbers. The current is controlled from the relay testing unit.
What's more, since you can use voltage as a reference instead of current, you can use RAGNAR alone or
together with some other relay testing unit.
RAGNAR, like SVERKER 750 and SVERKER 650, features rugged design and construction.
RAGNARPhase Shifter
RAG
NAR
1. Connect the Phase Shifter RAGNAR to the Relay Testing Unit SVERKER and to the protective relay.
2. Set the voltage to a low value by turning RAGNAR's voltage dial.3. Set the current obtained from SVERKER to a low value.4. Set the phase angle roughly using the + and - buttons.5. Start the test. Vary the voltage and phase angle using the two
dials on RAGNAR. Vary the current using the dial on SVERKER
APPLICATION EXAMPLE
OtherApplication field: The instrument is intended for use in high-voltagesubstations and industrial environments.Protection: Thermostatic switch, miniature circuit breakers, inputsprotected from overcurrents and -voltages.Mains voltage: 115/230 V AC (switchable) ± 10%, 50-60 Hz.Dimensions instrument: 356 x 203 x 241 mm (14" x 8.0" x 9.5")Dimensions transport case: 610 x 290 x 360 mm (24.0" x 11.4" x 14.2")Weight: 16 kg (35 lbs), 23.7 kg (52.2 lbs) with accessories and transport case.Test lead set: With touch-proof contacts, 4 x 1 m (40")/2.5 mm2
Warranty: 1 year The above specifications are valid at nominal input voltage and anambient temperature of +25°C (+77°F). Specifications are subjectto change without notice.
SPECIFICATIONS
Output voltage Variable, 0-105 V AC (no-load voltage)
Phase angle Variable, 0-360°
Output current Obtained from relay testing unit.
Outputs
Max. reference voltage 0 - 250 V AC
Max. reference current 0 - 10 A AC*
Voltmeter Range: 0-200 V. Accuracy: ± (0.7% of
reading + 0.2 V). Resolution: 0.1 V.
Phase angle meter Range: 0-360°. Accuracy: (U > 2.0 V,
IR > 0.5 A, UR > 10.0 V) ± 1°
Resolution: 0.1°
Current shunt 0.33 Ω
Measurement section
* The reference current passing through RAGNAR must notexceed 10 A. If you expect the current to be higher, you must useeither the ammeter output on the relay testing unit or an externalshunt.
ORDERING INFORMATION
RAGNAR Phase ShifterComplete with test lead set GA-00080 and transport case GD-00182Mains voltage: 115/230 VArt.No: CC-19090
Test lead set