Download - Qc & dormitory
•DESIGN OF DORMITORY (using STAAD.Pro )
• QUALITY CONTROL (QA/QC)
PRESENTATION ON
INTRODUCTION TO DORMITORY:
The word dormi means: sleep. So technically any "room" or space used for the purposes of "sleeping" can be called a dormitory.
Buildup Area = 311 Sq.M
Type = G+1
Designed For 80 People
Dormitory Room Size = 6.50x5.54 M
Loads Considered As Per IS : 875 (II)
Floor Height = 3.35m (10’6”)
PLAN OF GROUND FLOOR
PLAN OF FIRST FLOOR
Isometric view
Elevation
REQUIREMENTS PROVIDED:
Area Allotted = 3 Sq. M Per Person
Water Closet = 1 Per 6 Persons
Bath Room + urinal = 1 Per 6 Persons
Wash Basin = 1 Per 4 Persons
Store Room = 1.69x1.5 M.
Corridor = 1.8 M
DESIGN OF FOOTING:
Load From Column = 946 KN
Factored Load = 1419 KN
Column Size = 0.23x0.45 M
Footing Size = 2.0x2.2 M
Plinth Beams = 0.3x 0.15m At Sunken Portion
= 0.3x0.23m At Other Portions
Roof Beams = 0.3x0.23m At Sunken Portion
= 0.38x0.23m At Other Portion
DESIGN OF BEAM:
DESIGN OF COLUMN
Columns = 0.45x0.23m
Circular column provided for portico columns of size = 0.3ø m.
DEAD LOAD:
LIVE LOAD:
Quality:
•A Product Should Meet Its Specification.
Quality Control:
• Checking The Quality & Strength Of The Material Which Are Used In The Field.
• LaboratoryQuality Assurance :
•Field
INTRODUCTION TO QUALITY CONTROL:
SPECIFIC DUTIES OF QUALITY ENGINEER:-
• Conduct The Test For Aggregates, Sand Barrow Material Etc.
• To Check The Performance Of The Batching Plant Cement.
• Rectification Of Failure Of Any Structure.
• Monitoring Construction Methods With Respect To Environmental Changes.
• Maintaining Records Of All Test Results And Approvals Or Rejection Of Completed Works.
• Accommodation For The Testing Laboratory & Office
• Technical Library
• Communication Facility
• Office Equipment
INFRASTRUCTURE:
TESTS:
• Sieve Analysis
•Specific Gravity
•Flakiness Index And Elongation Index
•Water Absorption Test
•Compressive Strength Test
•Slump Test
•Core Cutting Test
•Test On Cement
PRESENTEDBY
08UF1A011609UF5A014508UF1A0160
QUESTIONS/COMMENTS