MT9083 SeriesMT9083A/B/C ACCESS Master™850/1300 nm OTDR for Multimode Fiber 780/1310/1383/1490/1550/1625/1650 nm OTDR for Single Mode Fiber
Product Brochure
ACCESS Master Key Features •Readytotestinabout15seconds…andalldaywithoutrecharging •Specializedtestingmodessimplifyoperation •Highresolutionandhighdynamicrangeensurequickandthroughfiberevaluation •Intelligentanalysissoftwareidentifiesproblemsplices,connectorsandevenmacrobends •Rugged,sealeddesignprovidesyearsofserviceinthemostchallengingenvironments •IPtestingoptionverifiesthroughput,framelossandpoint-to-pointconnectivity •Testuptofourwavelengthswithasingleunit-singlemode,multimodeorboth •Uniquein-servicetestingwithouttheneedforexternalfilters •Verifyconnectorqualitywithoptionalconnectorinspectionmicroscope
2
All-in-One Solution that Reduces Testing Times to Install and Maintain FTTx, CATV, LAN, Access and Metro Networks
850/1300 nm OTDR for MMF 780/1310/1383/1490/1550/1625/1650 nm OTDR for SMF
Opticalfibersareakeytechnologyintoday’smoderncommunicationssystems,includingaccessnetworkssuchasFTTx,CATV,andopticalLANs.Moreover,optical-fibertechnologiesareplayingincreasinglyimportantrolesinmobilecommunicationsanddigitalbroadcastingsystems.Techniciansmaintainingthesediversesystemsareforcedtocarryalargevarietyoftestequipmenton-site,includingOTDRs,LightSources,OpticalPowerMeters,VisibleLightSources,etc.,aswellasanotebookcomputerforevaluatingtheFTTxQoS.Ontheotherhand,fiberconstructionrequiresmeasuringinstrumentswithdifferentfunctionsandperformance.Asanexample,FTTxaccessnetworksusesinglemode(SM)fiberwhereasopticalLANsusemultimode(MM)fiber.Inaddition,coreandbackbonenetworksutilizelongfiberswhileopticalaccessnetworksuseshortfibers,bothrequiringdifferenttypesofmeasuringinstrumentswithdifferentperformance.ButnowAnritsu’snewlineofMT9083ACCESSMasterOTDRssolvesalltheseproblemsbyprovidingallthemeasurementfunctionsandperformancerequiredforopticalfiberconstructionandmaintenanceinacompact,lightweight,all-in-oneunitthateliminatestheburdenofcarryingmanydifferenttestsetsandinstrumentson-site.Whateveryourwork,constructionormaintenance,longhaulorintra-building,AnritsuhasanMT9083modelforyourneeds.
MT9083 ACCESS MASTER SERIES OVERVIEW
MT9083 SeriesMT9083A/B/C ACCESS Master™
850/1300 nm OTDR for Multimode Fiber 780/1310/1383/1490/1550/1625/1650 nm OTDR for Single Mode Fiber
Full Scpi Command Support for Remote Operation or Automated TestingMultiple Models to Meet Any Testing Requirement •MT9083A:Generalpurpose,goodrange,upto38dB. •MT9083B:Highperformance,enhancedrangewithfull1×64PONsupport,upto42dB. •MT9083C:Ultra-highperformance,enhancedrangewithfull1×128PONsupport,upto45dB.
3
Enhanced Performance to Reduce Testing Time by 75%TheMT9083BandMT9083Cseriesfeaturehighdynamicrange(upto45dB)allowingfibersover200kmtobemeasured.Itisalsooptimizedatthemostcommonlyusedpulsewidthslike100nstoprovideexcellentresolutionandmeasurementdistancewhilegreatlyreducingtesttime.
New Feature Highlight
Optimized for Verifying Pon Splitters Up to 1 × 128 CountManyOTDRsclaimtobeabletotestsplitter-based,passiveopticalnetworks(PON)buttheMT9083deliversinawayotherswishtheycould.Withitshighdynamicrangeandquickdataacquisition,theMT9083providesunparalleledresolutionofsingleorcloselyspaced,cascadedsplittersuptoanindustry-leading1× 128count.
Feed cable from Central OfficeDrop Cable
Pedestal with splitter
OLT
COHome
Up to 1 128 count
Fig. 2: Improved measurement range from MT9083A to MT9083B/C (100 ns shown)
MT9083B/C(Enhanced Mode)
MT9083A
10 sec.
100 sec.
Wavelength: 1550 nm
Distance range: 50 km
Pulse width: 100 ns
20 40 60 80 100 120 (sec)
Fig 1: Typical PON 1 × 64 count System Measurement from the customer premise.
TheMT9083BorCEnhancedRangeModeandaPulsewidthof100nsprovidesexcellentdynamicrangewhilenotcompromisingdeadzoneresolutiontoclearlydisplaymultiple,highlosssplitters.
200 m
MT9083A Noise Floor
Measurementtime:10secMT9083B/C Noise Floor
Designed with the Features that Matter Most
Quick Startup TheACCESSMasterisreadyformeasurementabout15secondsafterpower-onsoproductiveworkcanstartimmediately.
Long Battery LifeSinceACpowerisnotalwaysavailablewhereyouneedit,especiallyatfiberpedestals,theMT9083typicallyprovidesupto8hoursofoperationonasinglecharge.Thiscoupledwithanoptionalcarcord(forcigarettelighteroperation)guaranteestheMT9083isreadywhenyouare.
PortableWithitslightweightdesignanduserfriendlydimensions,theMT9083isperfectfortheoutsideplantenvironmentandcaneasilybemanagedwithonehand.Theshoulderstrap(partoftheprotectoroption)furtherincreasesportabilitywhentravellingfromthetrucktothetestingsite.
RuggedTheMT9083featuresasolidcaseworkwithnofansorventstokeepdustormoisturefromenteringtheunit.Inaddition,theprotectoroption(MT9083A/B/C-010)includesrubberbumpersandadisplaycoverforadditionalprotectionfromthoseminormishaps.
Generous Data StorageWiththeabilitytostoreupto1,000tracesininternalmemoryandupto30,000viaaUSBdevice,theMT9083offersplentyofstorageforcollectingandmanagingdata.
No Experience RequiredWiththeACCESS Master,theexperienceisbuiltin. Withspecializedtestingmodes,automaticparameterselection,PASS/FAILindicatorsaswellasfeaturestovirtuallyeliminatethechancetoget“bad”results,theMT9083canmakeanyoneseemslikea20yearveteran.Letithelpyoumasteryournetwork.
Easy “drag and drop” File TransfersWhentheMT9083isconnectedtoaPCviaaUSBcable,theinternalmemoryoftheACCESSMastercanbedirectlyaccessed.Datacanbeselected,draggedanddroppedintothePCmemory,greatlysimplifyingfiletransfers.TheMT9083alsosupportsuseofUSBmemorysticks.
Common OTDR Data Format TheMT9083supportstheuniversalTelcordiaSR-4731(issue2)formatmakingitcompatiblewithnotonlylegacyAnritsuandNetTestproducts,butwithmanyothervendorsdata.
Free and Simple Software UpgradesFirmwareupgradesareeasilyperformedviaUSBandavailablefromtheAnritsuwebsiteforregisteredusersorthroughAnritsucustomersupport.
Active fiber check NotonlycanOTDRmeasurementsbeeffectedwhentheopticalfiberisin-servicebutthereisapotentialriskofdamagetothetransmitterandOTDRreceiver.Topreventtheseproblems,theMT9083verifiesiflightispresentbeforestartingmeasurementandwillnottransmitifitis.Anon-screenwarningandinternalOTDRprotectionarealsopartofthisusefulfeature.
Integrated Macrobend DetectionWithmanytechniciansmakingtheswitchfromcopperinstallationstoopticalfiber,installationissuessuchasmacrobendsareboundtooccur.Tohelppreventthis,AnritsuhasdevelopedamacrobenddetectionfeaturefortheMT9083thatwillalerttechnicianswhenapossiblemacrobendispresent.Thisprovidesahigherqualityofserviceforthecustomerandeliminatescostlytroubleshootingforyou.
Wavelengths for Today’s NetworksSometimesyoujustneedmorethanthetraditional1310and1550nmwavelengthstocertifyyournextgenerationnetworks.TheMT9083offersahostofspecializedwavelengthsincluding1383nmforwaterpeakverificationofCWDMcarryingfibers,1650nm(withintegratedfilter)forlivefibertroubleshooting,1490nmforverificationofvoice,dataandIPbasedvideoservicesand780nmforin-servicetroubleshootingofFTTxnetworks-withouttheneedforanyadditionalfilters.
Whenbuyingproducts,youtendtochooseonesthatareinnovativeandfromestablishedcompanies.Whenyouneedtoinstallandmaintainopticalnetworks,thisshouldalsoapply.Withover50yearsofcombinedOTDRdesign,Anritsu,deliversthefeaturesthatmatter. Havingbeeninthetestandmeasurementbusinessforalongtime,weunderstandthatthingslikeperformance,portability,reliability,easyoperationandofcoursepriceareimportant.
4
Compact, Light Weight and All-in-one
TheMT9083deliversfullfeaturedOTDRperformancepluslosstestsetandqualityofservicemeasurementinasurprisinglysmallandlightweightpackage.Atonly28.4cmwide× 20 cm tall ×7.7cmdeepand2.2kg(4.8lbs.),itisfieldportable,yetruggedenoughtowithstandtheoutsideplantenvironment.Whenequippedwithpowermeter,visuallightsourceandIPtestoptions,itreplacesseveral,largerpiecesoftestequipment.
Upto8hoursbatterylifeplusquickrecharge
OpticalPowermeteroptionswithupto+30dBmmeasurement range
Visiblelasersourceforeasyfiberidentificationandbend/breaklocation
Uptofourwavelengthsfromasingleportforanyapplication
DualUSBportsforeasydatatransferandconnectorinspectionmicroscope
IPoptionsforverifyingQoSof10/100/1000MBlinks
Numerickeypadwithdedicatedkeysforeasyoperation
Dedicatedfunctionkeysforselectingparameters
Rotarydialforprecisioncursormovement
Arrowkeysforquickzoomingandnavigationthroughmenus
STARTkeyforsimpleone-buttontesting
6.5inchcolor,TFT-LCDdisplaywithsimplemenus
Withitsversatilebuilt-infunctions,theACCESSMasterofferstheidealsolutionforefficientopticalfiberconstructionandmaintenance.
All-in-one Test Set
Therearetwotypes—aStandardtypeforindooruse,and anEnhancedtypeforusebothindoorsandoutdoors
5
Improved Short Fiber AnalysisAneventdeadzoneoflessthan1m(80cmtypical)andasamplingresolutionof5centimetersallowtheMT9083toevaluateconnectionsandtroubleshootcentraloffice,FTTxandintra-buildingfaultswithease–providingalevelofdetailneverbeforeseen.
Fig. 3: With its high resolution optics, the MT9083 provides exceptional detail allowing users to quickly determine where the problem is-even when events are closely spaced.
Full PON Testing ManyOTDRsclaimtobeabletotestPONsbutbeingabletodoitwithbothhighresolutionandhighrangeiswhatsetstheMT9083B/Capart.Splittersuptoasingle1×128orcloselyspaced,cascadedsplittersarecompletelyandaccuratelymeasuredwithindustryleadingresolution.
Waveform Comparison FunctionComparecurrentandstoredtracedatatoeasilyassesschangesovertimeandtolocateproblemsbeforetheyeffectserviceorcomparetracesatdifferentwavelengthstoidentifyinstallationissuessuchasmacrobending.
Supports Two Display Types Therearetwotypesof6.5inch,TFTcolorLCDs:thestandardtype(MT9083A/B/C),offeringeasyviewingforindoors,andtheenhancedtype(MT9083A1/B1/C1),offeringeasyviewingforworkingbothindoorsandoutdoors-evenindirectsunlight.
Extended Range Testing of 200 + km FibersInadditiontoitssuperbhigh-resolutionperformance,theMT9083alsofeaturesupto45dBofdynamicrangeallowingittoeasilytest200+kmspansmakingitaveryusefultoolforanynetworktype.
Dual-Mode High Resolution/Enhanced Range OperationWhilemanyOTDRsprovidegooddeadzoneresolutionorhighdynamicrange,theMT9083A-073,MT9083BandMT9083Cseriesfeaturesadual-modedesignthatallowsa singleunittoexcelinbothcategories.Theusercansimply selectHIGHRESOLUTION(HR)modeorENHANCEDRANGE(ER)basedonthecurrenttaskathand.WhenHRmodeisselected,thesemodesprovidesgoodmeasurementrangewithanindustryleadingdeadzone(<1m).WhenERmodeisselected,theyprovidesunparalleledperformanceformeasurementdistance,measurementspeedanddeadzone-allowinga100kmfibertobetestedinlessthan10seconds.ERmodeisalsousedfortestingPONnetworkswithupto128branches.
Up to 150,001 Data Points for Increased AccuracyTheMT9083Cseriesalsocollectsupto150,001witharesolutionofjust2m.Thisprovidesthenecessarydetailwheninstallingandmaintainingfiberspans.
Event Table with User Defined Thresholds PASS/FAILthresholdsforkeyacceptancecriteriasuchasspliceloss,connectorlossandreflectancecanbesetintheMT9083allowingtechnicianstoeasilyassessafiber’scondition.Failingvaluesareclearlyhighlightedintheeventtablealertingtechniciansofpotentialproblems.
Multiple Wavelengths and ModelsWithnineavailablewavelengthsspanningbothsinglemodeandmultimode,theACCESSMasterMT9083issuretomeetyourindividualneeds.Uptofourofthesewavelengthscanbecombinedintoasingleopticaloutputprovidingfullspectrumcharacterization.
Evaluationofaccessnetworksrangingfromafewkilometerstometronetworksreachingupto100kminlengthisbecomingcommonplace,requiringOTDRstohavetheperformanceandfunctionsforevaluatingbothshortandlongfibers.Designedwiththisinmind,theACCESSMasterdeliversonbothfronts.
Exceptional OTDR Performance from the World’s First OTDR Manufacturer
Fig. 4: Spans of over 200 km are also easily tested making the MT9083 the only tool you will need - for any network type.
Convenient Features
6
Fig. 5: MT9083B and MT9083C series provides high range and excellent resolution of PON systems
Simple OperationTosimplifytesting,theMT9083featuresdedicatedmeasurementmodesviathetopmenutoautomateandsimplifythetaskathand.
NETWORKS PC Software for Analysis and ReportingOncethedataiscollected,NetWorksPCemulationsoftwaremakesanalysisandreportgenerationabreeze.Professionalreportsincludingspliceloss,fiberacceptanceandexceptionsaswellasvariousprintingoptionsarepossiblewithonlyafewmouseclicks.
Productsthatoffermanyfeaturesareoftencomplicatedtouse.TheACCESSMasterhowever,simplifiesoperationbyofferingtask-specifictestingmodesthatautomatetestingandguidenoviceusers.Dedicatedtestingmodesareavailableforfaultlocation,cableinstallation,lossbudgettesting,visualfaultlocationandIPtesting.
Solutions for Various Measurement Needs
Fig. 6: Dedicated measurement modes simplify testing for any skill level.
Fault LocationFAULTLOCATEmodeisdesignedforthenoviceorsomeonewhoonlyusesanOTDRoccasionally.SimplyconnectthefiberandpressSTART.Theunitwillverifythefiberisconnectedcorrectly,selecttestingparametersandprovideatextresponseindicatingfault/breaklocation-easytoreadresultsforanyskilllevel.
General OTDR Testing Forthosewhohavemoreexperienceorwouldliketoperformmoreadvancedtesting,STANDARDOTDRmodeallowstheusertosetallparametersandcomparetracesmanually,automaticallyorsomewhereinbetween.
Optical Fiber Construction and CertificationWhenfinalcableacceptanceisthetaskathand,CONSTRUCTIONmodegreatlysimplifiesoperationthroughitsinnovativewizard.Selecttherequiredtestingwavelengths,numberoffibersandfilenamingschemeandconstructionmodeactsastheprojectmanagerguidingtheuserthroughthetesting,whileensuringconsistencywithtestingparametersandfilenames-virtuallyeliminatinguserinducederrorsandmissingfiles.
ValueWhateveryourconstructionormaintenanceneeds,thenewACCESS Master MT9083 is designed to reduce the time toinstall,commissionandmaintainyouropticalnetworks–withoutbreakingyourbudget.
Fig. 7: Comprehensive, professional reports are easily generated
7
Template Feature Tosimplifyfiberacceptance,theAccessMasterincorporatesanon-the-flytemplatefeaturetoquicklylocateandmeasureallsplicesinafibercable.Inaddition,anon-screenhighlightblocksouttheexpectedsplicelocationsduringtraceacquisition.
Fig. 8: Template Mode
Remote Command Support Tosimplifyandautomatetestinginmanufacturingandlabenvironments,theMT9083supportsSCPIcommands.ThroughtheuseofaUSBconverterandacommonscriptingprogramsuchasLabViewTM,theMT9083canbequicklyintegratedandimmediatelyreducetestingtimes,Remotecontrolcanalsobeusedforremote,unmannedmonitoringapplications.
Standard Stabilized Light SourceTheOTDRportalsofunctionsasastabilizedlightsourceprovidingcontinuouswave,270Hz,1kHzand2kHzmodulationsforeasyfiberidentification.Thisisstandardequipmentonallsinglemodemodels-achargeableoptiononmostotherOTDRs.
Standard or Optional Integrated Power MeterInthebaseunit,theOTDRportalsofunctionsasanintegratedpowermeterforverificationofopticalpowerlevels.Additionalpowermeteroptionsareavailableforhigherpowertransmissionsandloop-backtesting.
Visual Laser Source for Easy Fault Location and Fiber IdentificationAVisibleLightSourceisusefulfortrackingdownbadconnections,splicesandfibermanagementissuessuchasmacrobends.TheoptionalVisibleLightSourceisfactoryinstalledintheMT9083andfeaturesupto5km(3miles)ofoperation.
AnOTDR,OpticalPowerMeter,VisibleLightSource,andIPtesterarebuiltintoAnritsu’scompact,light-weightMT9083supportingtasksrangingfromsearchingforfaultsinopticalfiberstoQoSevaluationtoFTTxtroubleshootingwithjustoneunit.
A True All-in-One Tester
Data Table for Saved ResultsLosstestsetmeasurementsformultiplewavelengthscanbesavedintoaresultstableforeasycomparisonandarchiving.ThetablecanalsobesavedasatextfileandexportedtoaPCspread-sheetprogramforfurthermanipulationorintegrationintoastandardcompanytemplate.
Video Inspection Probe SupportWhenequippedwiththeoptionalconnectorvideoinspectionprobe(VIP),theMT9083becomesapowerfultoolforevaluatingconnectorcleanlinessandquality.Connectorendfacescanbesafelyviewedandimagesstoredtodocumentallaspectsofyournetwork.
FaultsthatcausedropsinFTTxservicespeedarehandleddifferentlyaccordingtowhetherthecauseisoutsideorinsidethebuilding.Inaddition,businessusersarestartingtothinkaboutguaranteedbandwidthservicesandhigher-speedgigabitservices.TheACCESSMasterhasabuilt-inIPNetworkConnectionCheckfunctionthatcanbeusedforbothopticalfibersandopticalaccessQoSevaluation.
Connection and Ping TestsThefirststepintestingaserviceistoverifycontinuity.Thebuilt-inIPConnectionTestFunctionsupportsbothPPPoEandDHCPservices.
FTTx Download Speed EvaluationFTTxserviceperformanceiseasilyevaluatedfromthedownloadthroughput.PreviousevaluationsystemswerealwayslimitedbythePCperformance(CPUspeed,memorysize,OS,load)andneverprovidedaccuratemeasurements.UsingtheMT9083DownloadThroughputMeasurementfunctionfreestheresultsfromtheimpactofPCperformanceandprovidesaccurateresults.ThisallowsthecausesofdropsinFTTxservicespeedstobepinpointedtothenetworksideortheuser’sPCside.
Throughput Measurement and Frame Counter TheACCESSMasterhasatwo-waythroughputmeasurementfunctionforefficientevaluationofguaranteedbandwidthservices.WhenanMT9083isconnectedtoeachendoftheservice,boththeuploadanddownloadspeedscanbeevaluated.Andsincethebuilt-inframecounterfunctionscanbeusedtomeasurereceivedframetypesandtocounterrorframes,networkusageefficiencycanbemeasuredeasilytoo.
Gigabit Ethernet SupportTheMT9083hasanoptionalbuilt-in1000BASE-TelectricalinterfaceforevaluatingGigabitEthernetthroughput(uptofulllinerate)forverifyingperformanceonincreasingcommonGigabitEthernetservice.
Faults IdentifiedWhenissuesarepresent,possiblecausesaredisplayedon-screentohelpisolatethesourceoftheproblem.
Complete Loss Test Set Features
Optical Access Network QoS Evaluation Using IP Testing
8
Fig. 9: VIP Mode
Item General Specifications
Dimensions and Mass
Withoutprotector(option010)Size:270(W)×165(H)×61(D)mm10.6×6.5×2.4inchesWeight:2.2kg(4.8lbs)includingbattery
Withprotector(option010) Size:284(W)×200(H)×77(D)mm11.2×7.9×3inchesWeight:2.9kg(6.4lbs)includingbattery
Display 6.5inchTFT-LCD(640×480,withbacklight,transparenttype),enhancedindoor/outdooroptionalInterface USB1.1,TypeA×1(memory),TypeB×1(USBmassstorage)
Data StorageInternalmemory:440MB(upto1000traces),Externalmemory(USB):upto30,000traceswith512MB
PowerSupply12VDC,100to240VAC,Allowableinputvoltagerange:90to264V,50/60Hz
BatteryType:LithiumionOperatingTime∗1:8hoursRechargeTime:<5hours(poweroff)
PowerSavingFunctionsBacklightoff:Disable/1to99minutesAutoshutdown:Disable/1to99minutes
VerticalScale 0.13,0.33,0.65,1.3,3.25,6.5,13dB/divIORSetting 1.400000to1.699999(0.000001steps)Units km,m,kft,ft,mi
LanguagesUserselectable(English,SimplifiedChinese,TraditionalChinese,French,German,Italian,Korean,Portuguese,Russian,SpanishandSwedish-contactAnritsuforavailabilityofothers)
SamplingPoints∗2 Normal:5001,Highdensity:20001or25001(MT9083AandBseries),upto150,001(MT9083Cseries)SamplingResolution∗3 5cm(min.)ReflectanceAccuracy Singlemode:±2dB,multimode:±4dBDistanceAccuracy ±1m±3×measurementdistance×10-5±markerresolution(excludingIORuncertainty)
Distance RangeSinglemode:0.5,1,2.5,5,10,25,50,100,200km(MT9083AandBseries,except780nm:0.5,1,2.5km) 0.5,1,2.5,5,10,25,50,100,200,300km(MT9083Cseries)Multimode:0.5,1,2.5,5,10,25,50,100km
Testing Modes
Faultlocate:Providesend/breaklocation,endtoendloss,fiberlengthStandardOTDR:Userselectableautomaticormanualset-upConstructionOTDR:Automated,multi-wavelengthtestingLightsource:StabilizedLightsource(CW,270Hz,1kHz,2kHzoutput)Losstestset(optional):PowermeterandLightsourceConnectorVideoInspectionProbeVisualfaultlocator(optional):Visibleredlightforfiberidentificationandtroubleshooting
FiberEventAnalysis
Autoormanualoperation,displayedintableformatUserdefinedPASS/FAILthresholds:-Reflectiveandnon-reflectiveevents:0.01to9.99dB(0.01dBsteps)-Reflectance:–70.0to–20.0dB(0.1dBsteps)-Fiberend/break:1to99dB(1dBsteps)Numberofdetectedevents:upto99Macrobend detection
OTDR Trace Format Telcordiauniversal.SOR,issue2(SR-4731)
Other Functions
Realtimesweep∗4:0.15sec.Lossmodes:2pointloss,dB/km,2pointLSA,spliceloss,ORLAveragingmodes:Timed(1to3600sec.)LiveFiberdetect:VerifiespresenceofcommunicationlightinopticalfiberConnectioncheck:AutomaticcheckofOTDRtoFUTconnectionqualityTraceoverlayandcomparison,Templatefunction,USBkeyboardsupport,Remotecontrol,VideooutputtoPC
EnvironmentalConditions
Operatingtemperatureandhumidity:0°to+40°C(MT9083AandBseries),<80%(non-condensing) 0°to+45°C(MT9083Cseries),<80%(non-condensing)Storagetemperatureandhumidity:–20°to+60°C,<80%(non-condensing)Vibration:ConformingtoMIL-T-28800EClass3Dustproof:MIL-T-28800EClass2Dripproof:IP51(IEC60529),JISC0920TYPEI
EMC EN61326-1,EN61000-3-2
LVD EN61010-1
Notes∗1:Typical,backlightoff,sweepinghaltedat25˚C,6hourstypicalcontinuoustesting∗2:Eitherhighdensityvalueisselecteddependingondistancerange∗3:Except780nm∗4:Resolution:LowDensity.Exceptmodels062,068-1sec.orless
Specifications
MT9083A/B/C ACCESS Master Common Specifications
9
10
OTDR Specifications
Options HR/ERMode Wavelength∗5 Fiber Type Pulse width Dynamic Range∗6,7 Deadzone
(Fresnel)∗8Deadzone
(Backscatter)∗9
MT9
083C 053 √ 1310/1550nm±25nm
Single Mode(SMF)10/125µm ITU-TG.652
3,10,20,50,100,200,500,1000,2000,4000,10000,20000ns
45/45 dB
≤1m,≤0.8m(typ.)
≤3.8/4.3m25/25 dB ∗10
(Pulsewidth:100ns)
057 √ 1310/1550/1625 nm ±25nm
45/45/43 dB≤3.8/4.3/4.8m25/25/23 dB ∗10
(Pulsewidth:100ns)
MT9
083B
053 √ 1310/1550nm±25nm
Single Mode(SMF)10/125µm ITU-TG.652
3,10,20,50,100,200,500,1000,2000,4000,10000,20000ns
42/41 dB ∗11
≤1m(80cmtyp.)
≤5/5.5m
055 √ 1310/1550nm±25nm,1650 nm ±5nm 42/41/35 dB ∗11 ≤5/5.5/6.5m
056 √ 1310/1490/1550nm±25nm 40/39/39 dB ∗11 ≤6/6.5/7.5m057 √ 1310/1550/1625nm±25nm 40/39/38 dB ∗11 ≤6/6.5/7.5m
058 √ 1310/1490/1550/1625 nm±25nm 38/37/37/36 dB ∗11 ≤7/7.5/7.5/8.5m
059 √ 1310/1550/1625 nm ±25nm,1383nm±2nm 38/37/37/36 dB ∗11 ≤7/7.5/8.5/7.5m
063 √ 1310/1550nm±25nm,850/1300nm±30nm
HYBRID(SMF/MMF)∗11
SMF:aboveMMF:3,10,20,50,100,200,500,1000,2000,4000 ns850nm:Notsupport1000,2000,4000ns
42/41 dB ∗11
29/28 dB ∗11≤5/5.5m,≤4/5m(3/4mtyp.)
MT9
083A
050 1310nm±25nm
Single Mode(SMF)10/125µm ITU-TG.652
3,10,20,50,100,200,500,1000,2000,4000,10000,20000ns
38.5dB
≤1m(80cmtyp.)
≤5m051 1550nm±25nm 37 dB ≤5.5m052 1645 nm to 1655 nm 33.5dB ≤6.5m073 √ 1310/1550nm±25nm 38/36.5dB ≤5/5.5m
054 1550nm±25nm,1645 nm to 1655 nm 36/33.5dB ≤5.5/6.5m
055 1310/1550nm±25nm, 1645 nm to 1655 nm 37.5/36/33.5dB ≤5/5.5/6.5m
056 1310/1490/1550nm±25nm 36/34.5/34.5dB ≤6/6.5/6.5m
057 1310/1550/1625nm±25nm 36/34.5/31.5dB ≤6/6.5/7.5m
058 1310/1490/1550/1625 nm±25nm 34/32.5/32.5/29.5dB ≤7/7.5/7.5/8.5m
059 1310/1550/1625 nm ±25nm,1383nm±2nm 34/32.5/29.5/33dB ≤7/7.5/8.5/7.5m
060 1490nm±25nm 36.5dB ≤5.5m061 1625nm±25nm 33.5dB ≤6.5m062 780nm±20nm
1550nmabove780nm:5,10ns
8dB(10ns) ≤1m ≤7m
068 780nm±20nm,1550nm±25nm 8/36.5dB
≤1m1550nm:(80cmtyp.)
≤7/5.5m
063 1310/1550nm±25nm,850/1300nm±30nm
HYBRID(SMF/MMF)∗12 Same as SMF & MMF 38/36.5dB,
28/27 dB≤1m(80cmtyp.)
≤5/5.5m,≤4/5m(3/4mtyp.)
064 850/1300nm±30nmMultimode(MMF)62.5/125µm∗12
3,10,20,50,100,200,500,1000,2000,4000ns850nm:NotSupport1000,2000,4000ns
28/27 dB ≤4/5m(3/4mtyp.)
065 850nm±30nm 28 dB ≤4m(3mtyp.)
LaserSafety∗13IECPub60825-1:2001Class1:option051,052,054,060,061,062,068IECPub60825-1:2001Class1M:option050,053,055,056,057,058,059,063,064,065,07321CFR1040.10ExcludesdeviationscausedbyconformancetoLaserNoticeN.50(issued26July2001)
l2
1.5 dB
0.5 dBl1: Fresnel reflectionl2: Back-scattered light
l1
∗5:25°C,Pulsewidth:1µs(allexcept850,1300,780nm), 850/1300nm:100ns,780nm:10ns
∗6:Pulsewidths:20µs(Options050to061,063,068,073,1310/1550nm)atDistancerange:100km Pulsewidth:4µs(Options063,0641300nm)atDistancerange:25km Pulsewidth:500ns(Options063,065850nm)atDistancerange:25km Pulsewidth:10ns(Options062,068780nm)atDistancerange:2.5km Averaging:180sec.,SNR=1,25°C
∗7:Dynamicrange(one-wayback-scatteredlight),SNR=1:TheleveldifferencebetweentheRMSnoiselevelandthelevelwherenearendback-scattering
occurs.
Distance
SNR = 1
Leve
l
∗8:Pulsewidth:3ns(Options050to061,063,064,065,068,073,1550nm) Pulsewidth:5ns(Options062,068,780nm) Returnloss:40dB,25˚C(Refertothefigureright)
∗9:Pulsewidth10ns,returnloss55dB,Deviation±0.5dB,25°C (Options050to055,060to063,068,073,MT9083C-057.Allexcept850/1300nm) Pulsewidth20ns,returnloss55dB,Deviation±0.5dB,25°C (Options056to059,exceptMT9083C-057) Pulsewidth3ns,returnloss40dB,Deviation±0.5dB,25°C (Options063to065.850/1300nm)
∗10:Pulsewidth:100ns(ERMode),Distancerange:100km Averaging:180sec.,SNR=1,25°C
∗11:Typical.Subtract1dBforguarantee∗12:Atmeasurementof50/125µmMMFiber,thedynamicrangedropsbyabot3.0dB∗13:Safetymeasuresforlaserproducts
ThisoptioncomplieswithopticalsafetystandardsinClass1,1MofIEC60825-1; thefollowingdescriptivelabelsareaffixedtotheproduct.
11
Light Source Specifications – Standard on all models ∗14
Stabilized Light Source(through OTDR port)
Item SpecificationWavelength∗16 Same as OTDR
SpectralWidth∗16≤5nm(1310nm) ≤10nm(1490/1550/1625nm), ≤3nm(1650nm),≤1nm(1383nm)
WavelengthAccuracy850/1300/1310/1490/1550/1625nm:±30nm780nm:±20nm,1383nm:±2nm,1650nm:±5nm
FiberType Same as OTDROpticalConnector Same as OTDROutputPower∗16 –5±1.5dBmOutputStability∗17 ±0.1dBModesofOperation∗18 CW,270Hz,1kHz,2kHzLaserSafety Same as OTDR
Loss Test Set Specifications – Optional on all Models ∗14, ∗15
Power meters (004, 005 and 007)OptionNumber MT9083A/B/C-007 MT9083A/B/C-004 MT9083A/B/C-005
FiberTypeSingleMode:10/125µm(G.652), Multimode:62.5/125µm
SingleMode:10/125µm(G.652)∗PConlyforUPCconnector SingleMode:10/125µm(G.652)
Measurement Range∗20 –67to+6dBm∗21 –50to+23dBm –43to+30dBmWavelengthRange 750 nm to 1700 nm 1200 nm to 1700 nm
CalibratedWavelengths850,1300,1310,1383,1490,1550,1625,1650nm
1310,1383,1490,1550,1625,1650nm
OpticalConnectorUniversal–usesLP-XX adapters
Universal–usesJXXXXadapters(sameasOTDR)
Universal–usesMA9005Badapters
Accuracy∗22 ±5%
Modulation CW,270Hz,1kHz,2kHz
Features Storereference,losstable
Visible Light Source (Option 002)
CentralWavelength 650nm±15nm(at25˚C)OpticalOutput 0±3dBm(CW)
OutputOpticalFiber 10/125µm,SMF(ITU-TG.652)
OpticalConnector 2.5mmuniversal
LaserSafety∗23 IECPub60825-1Class3R,21CFR1040.10ExcludesdeviationscausedbyconformancetoLaserNoticeN.50(issued26July2001)
Environmental Same as OTDR
∗14:Somemodelsdonotsupportbuilt-inlightsourceandpowermeter (Seenextpage)
∗15:Ifoption004,005or007isordered,thestandardintegratedpowermeterisnotavailable
∗16:CW,25˚C
∗17:CW,0°to40˚C(±1˚C)differencebetweenmax/min.valuesover1minute, SM fiber 2 m
∗18:Modulation+1.5%with10minutewarmup
∗19:CWinput,–20dBmat1550nm,23˚C±2UsingMasterFCconnector∗20:Peakpower,subtract3dBformodulatedtones ∗21:–60to+3dBm(Option007@850nm)
∗22:CW,model007:At–10dBm,1310/1550nm, At–10dBm,850nm,25˚C
model004/005:At0dBm,1310nmand1550nmUsingMasterFCconnector,Afterzerooffset
∗23:Safetymeasuresforlaserproducts ThisoptioncomplieswithopticalsafetystandardsinClass3RofIEC60825-1;thefollowingdescriptivelabelsareaffixedtotheproduct.
Power Meter Specifications – Standard on all models ∗14
Standard Integrated Power Meter ∗15
(through OTDR port)Item Specification
MaximumInput +10dBmMeasurement Range –50to–5dBmFiberType Same as OTDROpticalConnector Same as OTDRAccuracy∗19 ±6.5%
SupportedWavelengths
1310,1550,1625nmplus∗1490nm(056,058,060)∗1383nm(059)∗1650nm(050,051,053,054,055,057,061,063,068,073)
Features Storereference,losstable
LS: MT9083A/B/C standard built-in stabilized Light Source, OPM: MT9083A/B/C standard built-in Optical Power Meter
Battery pack: Z0921A AC adapter: Z0933A
Standard Light Source and Power Meter Built-in
Options MT9083A/B/C-001 MT9083A/B/C-011
Name IPNetworkConnectionCheckFunction GigabitEthernetUpgrade
MeasurementIFIFSpeed
10BASE-T/100BASE-TX:1port 10BASE-T/100BASE-TX/1000BASE-T:1port
10M/100MFull,10M/100MHalf,Autonegotiation,AutoMDI/MDI-X
ConnectivityCheckConnection ModeVLAN
OK/NGJudgmentPPPoE,DHCP,ManualVLANsetupispossibleintheDHCPModeandManualMode.SingleVLANtagissupported.VID:1to4094,COS:0to7
Connection TestPing TestTrace Route Test
CanbeexecutedaftertheconnectionisestablishedbyusingtheConnectivityCheckfunction.NumberofTimes:1to999,TimeoutThreshold:1to60sTimeoutThreshold:2to60s,Hops:1to255
DownloadThroughput MeasurementDownloadFileSizeDownloadThroughputValue
CanbeperformedaftertheconnectionisestablishedbyusingtheConnectivityCheckfunction.Thefullwirerateissupported.Upto1GBDownloadfilesize[bits]/Downloadtime[s]
ThroughputMeasurementFrameSize
Transmit Rate Transmit Duration Time ResolutionLossTolerance
CanbeperformedaftertheconnectionisestablishedbyusingtheConnectivityCheckfunction.64,128,256,512,768,1024,1280,1518,9018,9618:Theframesize9018and9618canbeselectedwhenthelinkspeedis1000M.1to100%ofthelineband(100%atfull-wirerate),instepsof1%5,10,15,20,30,60,180,300s1%or5%ofthelineband0,0.01,0.1,1,5,10%
Counter MeasurementMeasurement TimeFrameType
1to720min.,instepsof1min.Allframe,OnlyPPPoEframe,OnlyVLANframe
12
IP Testing Option
Options OpticalPort LS OPMMT9083A-050 1310 nm SM √ √MT9083A-051 1550 nm SM √ √MT9083A-052 1650 nm SM √ —MT9083B/C-053 1310/1550 nm SM √ √MT9083A-073 1310/1550 nm SM √ √
MT9083A-0541550 nm SM √ √1650 nm SM √ √
MT9083A/B-0551310/1550 nm SM √ √1650 nm SM √ √
MT9083A/B-056 1310/1490/1550 nm SM √ √MT9083A/B/C-057 1310/1550/1625 nm SM √ √MT9083A/B-058 1310/1490/1550/1625 nm SM √ √MT9083A/B-059 1310/1550/1625/1383 nm SM √ √
Model OpticalPort LS OPMMT9083A-060 1490 nm SM √ √MT9083A-061 1625 nm SM √ √MT9083A-062 780 nm SM — —
MT9083A/B-063850/1300 nm MMF √ —1310/1550 nm SM √ √
MT9083A-064 850/1300 nm MMF √ —MT9083A-065 850nmGI √ —
MT9083A-068780 nm SM — —1550 nm SM √ √
Battery LithiumIonsecondarybatteryVoltage,Capacity 11.1V,4200mAhDimensions and Mass 53(W)×19(H)×215(D)mm,330gtyp.
OperatingTemperatureCharging:+5°to+30˚C,≤80%RHDischarging:–20°to+60˚C,≤80%RHStorage:–20°to+50˚C,≤80%RH
RatedACInput 100to240Vac,50Hz/60HzRatedDCOutput 12Vdc,3ADimensions and Mass 60(W)×34(H)×122(D)mm,331±5gtyp.
EnvironmentalConditions
Operatingtemperature:0°to+40˚C,20to80%R.H.Storagetemperature:–20°to+80˚C,10to95%R.H.
Ordering Information
13
Please specify the model/order number, name and quantity when ordering.The names listed in the chart below are Order Names. The actual name of the item may differ from the Order Name.
1) Specify Base UnitIncludesACCESSMasterOTDR,ACcharger/adapter,linecord,batterypack(1),printedquickuser'sguideanduser’smanual(CD).
Model/Order No. Description
MT9083A/B/C ACCESSMasterbaseunit,StandarddisplayforindooruseMT9083A1/B1/C1 ACCESSMasterbaseunit,Enhanceddisplayforindoor/outdooruse
2) Select Optical ConfigurationIncludeschoiceofOTDRconnectoradapters–selectinstep5below.
MT9083C Series (OTDR Ultra-high Performance Model)
Model/Order No. HR/ER Mode Wavelength Application
MT9083C-053 √ 1310/1550nm,SM General-purposemodelforconstruction,maintenanceandfaultlocation
MT9083C-057 √ 1310/1550/1625nm,SM General-purposeplusenhancedmacrobenddetectionat1625nm
MT9083B Series (OTDR High Performance Model)
Model/Order No. HR/ER Mode Wavelength Application
MT9083B-053 √ 1310/1550nm,SM General-purposemodelforconstruction,maintenanceandfaultlocation
MT9083B-055 √ 1310/1550nm&1650nm,SM General-purposemodelsforconstruction,maintenanceandfaultlocationplus In-servicemeasurement–integratedfiltertoblocktransmissions
MT9083B-056 √ 1310/1490/1550nm,SM General-purposeplus1490nmforFTTx/PONapplicationsMT9083B-057 √ 1310/1550/1625nm,SM General-purposeplusenhancedmacrobenddetectionat1625nmMT9083B-058 √ 1310/1490/1550/1625nm,SM GeneralpurposeforanyapplicationorfullspectrumcharacterizationMT9083B-059 √ 1310/1383/1550/1625nm,SM General-purposeplussupportsWaterPeaktestingat1383nm
MT9083B-063 √ 850/1300nmMM,1310/1550nmSM Bestunitforcontractorsoranyonewhoinstallsormaintainshybridnetworks
MT9083A Series (OTDR Base Model)
Model/Order No. HR/ER Mode Wavelength Application
MT9083A-050 1310nm, SM General-purposemodelforconstruction,maintenanceandfaultlocationMT9083A-051 1550nm, SM General-purposemodelforconstruction,maintenanceandfaultlocationMT9083A-052 1650nm, SM In-servicemeasurement–integratedfiltertoblocktransmissionsMT9083A-073 √ 1310/1550nm, SM General-purposemodelforconstruction,maintenanceandfaultlocationMT9083A-054 1550nm&1650nm,SM General-purposemodelsforconstruction,maintenanceandfaultlocationplus
In-servicemeasurement–integratedfiltertoblocktransmissionsMT9083A-055 1310/1550nm&1650nm,SMMT9083A-056 1310/1490/1550nm,SM General-purposeplus1490nmforFTTx/PONapplications
MT9083A-057 1310/1550/1625nm,SM General-purposeplusenhancedmacrobenddetectionat1625nm
MT9083A-058 1310/1490/1550/1625nm,SM Generalpurposeforanyapplicationorfullspectrumcharacterization
MT9083A-059 1310/1383/1550/1625nm,SM General-purposeplussupportsWaterPeaktestingat1383nmMT9083A-060 1490nm,SM FTTx/PONtestingMT9083A-061 1625nm,SM Enhanced macrobend detectionMT9083A-062 780nm,SM FortroubleshootingliveFTTx/PONnetworks
MT9083A-068 780&1550nm,SM FortroubleshootingliveFTTx/PONnetworksplusgeneraltesting
MT9083A-063 850/1300nmMM,1310/1550nmSM BestunitforcontractorsoranyonewhoinstallsormaintainshybridnetworksMT9083A-064 850/1300nm,MM Multimode fiber modelMT9083A-065 850nm,MM Multimode fiber model
Note:Modelsnotedfeatureuser-selectableenhancedrange(ER)formeasuringPONsystems/detectingfaultsinshorttimeandhighresolution(HR)fortheshortestdeadzone.
3) Select Factory Installed OptionsMustbeaddedasseparate,chargeablelineitems.
Model/Order No. Description
MT9083A/B/C-010 Protectoroption(includesrubberbumpers,displaycoverandshoulderstrap)MT9083A/B/C-001 IPNetworkConnectionCheckFunctionMT9083A/B/C-011 GigabitEthernetUpgrade(requiresoptionMT9083A/B/C-001)
With Protector option -010Without Protector option -010
4) Select Loss Test Set OptionsOptical Power Meter
Must be added as separate, chargeable line items.
Model/Order No. Description
MT9083A/B/C-004 SMFOpticalPowerMeter(UPConly)
MT9083A/B/C-005 SMFHighPowerOpticalPowerMeter(UPC/APC)
MT9083A/B/C-007 SMF/MMFOpticalPowerMeter(UPC/APC)
Visible Light Source
Model/Order No. Description
MT9083A/B/C-002 VisibleLaserDiode
5) Select Connector TypesTheACCESSMasterMT9083canbeoptionedtofeatureuptothreeopticalports–singlemodeOTDR,multimodeOTDRandanOpticalPowerMeter(options-004,-005,and-007).Selectingasingleconnectorcodebelowwillpopulateallopticalportswiththatconnectortype orcustomercanselectdifferentadaptersbyspecifyingtheadapterforeachofthethreeopticalports–seeexamplesbelow.
Optical ConnectorsOne adapter type is provided for each port at no charge - must be added as separate line items.
NOTE: FC-APC and SC-APC are not available for MM OTDR or Optical Power Meter.
Model/Order No. Description Model/Order No. Description
MT9083A/B/C-025 FC-APCConnector-singlemodeOTDRonly(additionalchargeapplies) MT9083A/B/C-038 ST Connector
MT9083A/B/C-026 SC-APCConnector-singlemodeOTDRonly(additionalchargeapplies) MT9083A/B/C-039 DINConnector
MT9083A/B/C-033 LCConnector MT9083A/B/C-040 SC Connector
MT9083A/B/C-037 FC Connector MT9083A/B/C-043 HMS-10/AConnectorNote:UPCandAPCconnectorsarenotcompatible–theinternalopticsaredifferentandmustbespecifiedattimeororder.
14
Examples: 1) MT9083B-053 with MT9083B-004 Power Meter option Customercanspecify“MT9083B-040fortheSMOTDR”portand“MT9083B-037fortheOPM”portatnocharge.2) MT9083A-063 with MT9083A-007 Power Meter option Customercanspecify“MT9083A-040fortheSMOTDR”port,“MT9083A-037fortheMMOTDR”portand “MT9083A-037fortheOPM”portatnocharge.3) MT9083C-053 with no options Customercanspecify“MT9083C-026fortheSMOTDR”porthoweveranadditionalchargeapplies.
APCAngledPhysicalContactUPCUltraPhysicalContact
6) Select Accessories & Replacement ItemsAccessories
Must be added as separate, chargeable line items.
Model/Order No. Description
W2838AE MT9083SeriesACCESSMasterOperationManual(CD)
W2839AE HardcopyMT9083OperationManual
W3272AE HardcopyMT9083QuickUser'sGuide
B0582A SoftCarryingCase
B0583A HardCarryCaseforMT9083-attachestyle
B0549 HardCarryCaseforMT9083withhandleandwheels
Z0921A ReplacementBatteryPackforMT9083
Z0933A ReplacementACCharger/Adapter
Z0942A ExternalBatteryCharger
J1295 Car Plug Cord
OPTION-545VIP ConnectorVideoInspectionProbe(VIP)Option
NETWORKS PCEmulationSoftwareforDataAnalysisandReporting
MT9083A/B/C-ES210 12monthExtendedWarrantyService
MT9083A/B/C-ES310 24monthExtendedWarrantyService
Peripherals
BL-80R2 ThermalPrinterKit(mustalsoorderBL-100WACadapter,J1314printercableandBL-80-30paperrolls)
BL-100W ACAdapterforBL-80R2Printer
J1314 PrinterCableforBL-80R2Printer
BL-80-30 PrinterPaperforBL-80R2ThermalPrinter(10rolls/set)
Retrofit Options for existing units – unit must be returned to authorized service center
MT9083A/B/C-101 IPNetworkConnectionCheckFunction(Retrofit)
MT9083A/B/C-111 GigabitEthernetUpgrade(Retrofit-requiresoptionMT9083A/B/C-001orMT9083A/B/C-101)
MT9083A/B/C-110 ProtectorOption(Retrofit)
MT9083A/B/C-107 SMF/MMFOpticalPowerMeter(Retrofit)
MT9083A/B/C-104 SMFOpticalPowerMeter(Retrofit)
MT9083A/B/C-105 SMFHighPowerOpticalPowerMeter(Retrofit)
MT9083A/B/C-102 VisibleLD(Retrofit)
Replacement Adapters
Type OTDRandPowerMeters(MT9083A/B/C-004)
PowerMeter(MT9083A/B/C-005only)
PowerMeter(MT9083A/B/C-007only)
LC J1270 MA9005B-33 LP-LC
FC J0617B MA9005B-37 LP-FC
AngledFC(AFC) J0739A MA9005B-37 LP-FC
ST J0618D MA9005B-38 LP-ST
DIN J0618E MA9005B-39 LP-DIN
HMS-10A J0618F MA9005B-43 N/A
SC(UPCorAPC) J0619B MA9005B-40 LP-SC
15
Basic KitsModel/Order No. Z1093B
Name MT9083B1-053-BKIT
Configuration
Model Name
MT9083B1MT9083B-053MT9083B-010B0582A
ACCESS MasterSMF1.31/1.55µm OTDRProtectorSoftCarryingCase
Model/Order No. Z1094A
Name MT9083A1-063-BKIT
Configuration
Model Name
MT9083A1MT9083A-063MT9083A-010B0582A
ACCESS MasterMMF0.85/1.3µm&SMF1.31/1.55µm OTDRProtectorSoftCarryingCase
Model/Order No. Z1254A
Name MT9083A1-073-BKIT
Configuration
Model Name
MT9083A1MT9083A-073MT9083A-010B0582A
ACCESS MasterSMF1.31/1.55µm OTDRProtectorSoftCarryingCase
Deluxe KitsModel/Order No. Z1095B
Name MT9083B1-053-DKIT
Configuration
Model Name
MT9083B1MT9083B-053MT9083B-010B0582AMT9083B-007MT9083B-002NETWORKS
ACCESS MasterSMF1.31/1.55µm OTDRProtectorSoftCarryingCaseSMF/MMFOpticalPowerMeterVisibleLDNetWorks
Model/Order No. Z1255A
Name MT9083A1-073-DKIT
Configuration
Model Name
MT9083A1MT9083A-073MT9083A-010B0582AMT9083A-007MT9083A-002NETWORKS
ACCESS MasterSMF1.31/1.55µm OTDRProtectorSoftCarryingCaseSMF/MMFOpticalPowerMeterVisibleLDNetWorks
Note:Specifytheopticalconnector.-"5)SelectConnectorTypes".
Soft Carrying Case (B0582A) Hard Carrying Case (B0583A)-Attache style Hard Carrying Case (B0549)
Anritsu Corporation 5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 JapanPhone: +81-46-223-1111Fax: +81-46-296-1238
• U.S.A.Anritsu Company1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A.Toll Free: 1-800-267-4878Phone: +1-972-644-1777Fax: +1-972-671-1877
• CanadaAnritsu Electronics Ltd.700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, CanadaPhone: +1-613-591-2003 Fax: +1-613-591-1006
• Brazil Anritsu Eletrônica Ltda.Praca Amadeu Amaral, 27 - 1 Andar01327-010-Paraiso-São Paulo-BrazilPhone: +55-11-3283-2511Fax: +55-11-3288-6940
• Mexico Anritsu Company, S.A. de C.V.Av. Ejército Nacional No. 579 Piso 9, Col. Granada11520 México, D.F., MéxicoPhone: +52-55-1101-2370Fax: +52-55-5254-3147
• U.K.Anritsu EMEA Ltd.200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K.Phone: +44-1582-433200 Fax: +44-1582-731303
• FranceAnritsu S.A.16/18 avenue du Québec-SILIC 72091961 COURTABOEUF CEDEX, FrancePhone: +33-1-60-92-15-50Fax: +33-1-64-46-10-65
• GermanyAnritsu GmbHNemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55
• ItalyAnritsu S.p.A.Via Elio Vittorini 129, 00144 Roma, ItalyPhone: +39-6-509-9711 Fax: +39-6-502-2425
• SwedenAnritsu ABBorgafjordsgatan 13, 164 40 KISTA, SwedenPhone: +46-8-534-707-00 Fax: +46-8-534-707-30
• FinlandAnritsu ABTeknobulevardi 3-5, FI-01530 VANTAA, FinlandPhone: +358-20-741-8100Fax: +358-20-741-8111
• DenmarkAnritsu A/SKirkebjerg Allé 90, DK-2605 Brøndby, DenmarkPhone: +45-72112200Fax: +45-72112210
• RussiaAnritsu EMEA Ltd. Representation Office in RussiaTverskaya str. 16/2, bld. 1, 7th floor.Russia, 125009, MoscowPhone: +7-495-363-1694Fax: +7-495-935-8962
• United Arab EmiratesAnritsu EMEA Ltd.Dubai Liaison OfficeP O Box 500413 - Dubai Internet CityAl Thuraya Building, Tower 1, Suit 701, 7th FloorDubai, United Arab EmiratesPhone: +971-4-3670352Fax: +971-4-3688460
• SingaporeAnritsu Pte. Ltd.60 Alexandra Terrace, #02-08, The Comtech (Lobby A)Singapore 118502Phone: +65-6282-2400Fax: +65-6282-2533
• IndiaAnritsu Pte. Ltd.
India Branch Office3rd Floor, Shri Lakshminarayan Niwas, #2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, IndiaPhone: +91-80-4058-1300Fax: +91-80-4058-1301
• P.R. China (Hong Kong)Anritsu Company Ltd.Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong KongPhone: +852-2301-4980Fax: +852-2301-3545
• P.R. China (Beijing)Anritsu Company Ltd.Beijing Representative OfficeRoom 2008, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 100004, P.R. ChinaPhone: +86-10-6590-9230Fax: +86-10-6590-9235
• KoreaAnritsu Corporation, Ltd.8F Hyunjuk Building, 832-41, Yeoksam Dong, Kangnam-ku, Seoul, 135-080, KoreaPhone: +82-2-553-6603Fax: +82-2-553-6604
• AustraliaAnritsu Pty. Ltd.Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, AustraliaPhone: +61-3-9558-8177Fax: +61-3-9558-8255
• TaiwanAnritsu Company Inc.7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, TaiwanPhone: +886-2-8751-1816Fax: +886-2-8751-1817
Specifications are subject to change without notice.
CatalogNo.MT9083Series-E-A-1-(4.00)PrintedinJapan13/OCT/2009ddcn/CDT
0909
Printed on Recycled Paper
Video Inspection Probe (OPTION-545VIP)