Foundations, Drainage, and Site Considerations
Presented byBernard Ray Tillery, P.E.
Amarillo Testing and Engineering
![Page 2: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/2.jpg)
“The function of a residential foundation is to support the structure. The majority of foundations constructed in Texas consist of shallow, stiffened and reinforced slab-on-ground foundations. Many are placed on expansive clays and/or fills. Foundations placed on expansive clays and/or fills have an increased potential for movement and resulting distress. National building codes have general guidelines, which may not be sufficient for the soil conditions and construction methods in the State of Texas. The purpose of this document is to present recommended practice for the design of residential foundations to augment current building codes to help reduce foundation related problems. Where the recommendations in this document vary from published methods or codes, the differences represent the experience and judgment of the majority of the committee members. On sites having expansive clay, fill, and/or other adverse conditions, residential foundations shall be designed by licensed engineers utilizing the provisions of this document: (Recommended Practice for the Design of Residential Foundations). Expansive clay is defined as soil having a weighted plasticity index greater than 15 as defined by Building Research Advisory Board (BRAB) or a maximum potential volume change greater than 1 percent. This provision should also apply where local geology or experience indicates that active clay soils may be present. We propose that local and state governing bodies adopt this recommended practice.” Excerpt from: Recommended Practice for the Design of Residential Foundations, Version 1, By the Texas Section American Society of Civil Engineers © 2002
![Page 3: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/3.jpg)
Load-bearing values of soils
For SI: 1 pound per square foot = 0.0479 kPa.
a. When soil tests are required by Section R401.4, the allowable bearing capacities
of the soil shall be part of the recommendations.
b. Where the building official determines that in-place soils with an allowable
bearing capacity of less than 1,500 psf are likely to be present at the site, the
allowable bearing capacity shall be determined by a soils investigation.
![Page 4: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/4.jpg)
New LanguageCity of Amarillo amendments to the 2006 IRC
“R401.2 Requirements. Foundation construction shall be
capable of accommodating all loads according to Section R301
and of transmitting the resulting loads to the supporting soil.
Fill soils that support footings and foundations shall be
designed, installed and tested in accordance with accepted
engineering practice. Gravel fill used as footings for wood and
Pre-cast concrete foundations shall comply with Section R403.” (added to the end of paragraph -Section R401.2)
Concrete foundations will be designed by registered design professional licensed in the State of Texas or constructed in
compliance with The Panhandle Residential Foundation Manual
![Page 5: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/5.jpg)
The path to design residential foundations
IB C 1 80 5 .8 .2re fe ren cesW R I/P T I
S la b o n G rad e F o un d atio n D es ign
R 40 3.1 .8F o u da tion s on E xp a ns ive S o ils
R 40 3.1 .4M in im u m F o un d a tio n D e p th
R 4 02 .2C o n cre te S tre ng th /Q u a lity
R 4 03 ..1S ize o f F o o ting
IR CF o un d atio ns
C h a pte r 4
![Page 6: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/6.jpg)
New for 2008 for use with the 2006 IRC
![Page 7: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/7.jpg)
NEW - Foundation Table
![Page 8: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/8.jpg)
AssumptionsThe Table R403.1(a) is based on the following assumptions and are considered mandatory criteria if application of these approved design standards are utilized: 1. The generic configurations shown in this table are based on procedures recognized by the Reference (4) Wire Reinforcement Institute’s (WRI) Design of Slab-on-Ground Foundations WRI/CRSI-81. 2. The effective Plasticity Index (PI) of the sub-grade/fill is less than or equal to 20 when computed by the methods presented by the WRI. The determination of satisfaction this criteria shall be provided by the Building Official. The supporting foundation soils are assumed to have a minimum allowable soil bearing capacity of 1500 psf. 3. The top 8” of subgrade or finished fill soil are processed as specified minimum 90% compaction plus or minus 5% moisture content based on the Standard Proctor (ASTM D-698). Comment - The City of Amarillo does not require, but recommends a minimum of 95% compaction plus or minus 3% based on the Standard Proctor (ASTM D-698). 4. Uniform Loads are distributed across the interior floor slabs at 200 psf for single story, 275 psf for two story, and 350 psf for three story residential structures. Variations in above stated loadings should be taken into consideration in the final individual configuration. Structural demands imposed by concentrated application of loadings should receive enhanced foundation support. 5. All reinforcing steel is Grade 60 (60,000 psi), and all concrete is 3000 psi @ 28 day’s cure. All reinforcement must have at least 3” of cover where exposed directly to soil. 6. The approved foundation design standards are considered minimum standards for the City of Amarillo. Selected design dimensions and reinforcement sizes that exceed these provided standards can generally be considered acceptable.
![Page 9: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/9.jpg)
Amarillo 2-pour Slab-on-Grade (Typical)
Brick Veneer – ISO board at base course
![Page 10: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/10.jpg)
Brick Veneer – mortar at base course
Amarillo 2-pour Slab-on-Grade (Code)
![Page 11: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/11.jpg)
Interior Foundation Beam
Must be installed at maximum intervals of 20’ and/or under load-bearing walls
![Page 12: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/12.jpg)
2-pour Slab-on-Grade (Energy Efficient)
![Page 13: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/13.jpg)
Monolithic Slab-on-Grade (Code)
![Page 14: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/14.jpg)
Monolithic Slab-on-Grade (Energy Efficient)
![Page 15: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/15.jpg)
Typical Crawl Space
![Page 16: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/16.jpg)
Pier Detail
![Page 17: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/17.jpg)
Formed 2-Pour Slab-on-Grade
![Page 18: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/18.jpg)
Fireplace footing
![Page 19: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/19.jpg)
Basements
• Section R310.1 Amend: Emergency escape and rescue required.
• Exception: (Add to end of paragraph) . or designed as an interior storm shelter less than 400 square feet.
![Page 20: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/20.jpg)
Trenched Basement - (Inset 6’ minimum)
![Page 21: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/21.jpg)
Formed Basement - (Inset 6’ minimum)
![Page 22: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/22.jpg)
Formed Basement – Exterior foundation
includes perimeter drainage system
![Page 23: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/23.jpg)
CMU Basement - (Inset 6’ minimum)
![Page 24: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/24.jpg)
CMU Basement - Exterior foundation
includes perimeter drainage system
![Page 25: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/25.jpg)
Accessory Buildings
The following foundation details are for free standing, single story less than 10’ wall
height, accessory to another use, limited to area of 600 square feet or less
![Page 26: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/26.jpg)
Slab-on-grade - accessory structure
![Page 27: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/27.jpg)
Treated floor - accessory structure
![Page 28: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/28.jpg)
NON-Treated floor - accessory structure
![Page 29: Prfm Presentation](https://reader036.vdocuments.us/reader036/viewer/2022062513/555604bed8b42a8a5f8b56cc/html5/thumbnails/29.jpg)
Questions?
Bernard Ray Tillery, P.E.
Amarillo Testing and Engineering
Thank you