Download - Pretreatment plant
1
2
PRESENTATIOPRESENTATIONN
KURIEMAT POWER STATION I KURIEMAT POWER STATION I
WATER PRE WATER PRE TREATMENTTREATMENT
AT MOL (SHJ) – JUL. 2007AT MOL (SHJ) – JUL. 2007
FORFOR
PART OF OPERATION TRAININGPART OF OPERATION TRAININGUPPER EGYPT ELECTRICTY PROD CO. & EGYPTIAN UPPER EGYPT ELECTRICTY PROD CO. & EGYPTIAN
ELECTRICITY HOLDING COMPANYELECTRICITY HOLDING COMPANY
3
4
RAW WATER TREATMENTRAW WATER TREATMENT
WATER WATER CHEMISTRYCHEMISTRY
5
WHAT IS WATER?WHAT IS WATER?COLOURLESS, ODOURLESS, TASTELESS LIQUIDCOLOURLESS, ODOURLESS, TASTELESS LIQUIDPOLAR LIQUIDPOLAR LIQUIDHIGH DIELECTRIC CONSTANT (81 @ 17°C)HIGH DIELECTRIC CONSTANT (81 @ 17°C)EXTREMELY GOOD SOLVENT POWEREXTREMELY GOOD SOLVENT POWERWEAK ELECTROLYTEWEAK ELECTROLYTEDENSITY OF 1.00 @ 4°CDENSITY OF 1.00 @ 4°CALLOTROPIC FORMS: ICE(SOLID) & STEAM(GASALLOTROPIC FORMS: ICE(SOLID) & STEAM(GAS))
RAW WATER TREATMENT - WATER RAW WATER TREATMENT - WATER CHEMISTRYCHEMISTRY
6
Chemical FormulaChemical Formula
H2OH+ OH-
(H2O)n
HOH
RAW WATER TREATMENT - WATER RAW WATER TREATMENT - WATER CHEMISTRYCHEMISTRY
7
The Water Molecule
HHO
104°
RAW WATER TREATMENT - WATER RAW WATER TREATMENT - WATER CHEMISTRYCHEMISTRY
8
• TWO HYDROGEN ATOMS, 104deg APARTTWO HYDROGEN ATOMS, 104deg APART• DIPOLAR - POSITIVE CHARGE ON DIPOLAR - POSITIVE CHARGE ON
HYDROGEN. NEGATIVE CHARGE ON OXYGENHYDROGEN. NEGATIVE CHARGE ON OXYGEN• DUE TO HYDROGEN BOND HAS HIGH DUE TO HYDROGEN BOND HAS HIGH
ENERGY CONTENTENERGY CONTENT• HYDROGEN BOND CAUSES ICE TO EXPAND HYDROGEN BOND CAUSES ICE TO EXPAND
& CREATES SURFACE TENSION.& CREATES SURFACE TENSION.
WATER COMPOSITIONWATER COMPOSITION• WATER FORMULA = HWATER FORMULA = H2200
RAW WATER TREATMENT - WATER RAW WATER TREATMENT - WATER CHEMISTRYCHEMISTRY
9
The Water cycleThe Water cycleNatural SystemNatural System
RAW WATER TREATMENT - WATER RAW WATER TREATMENT - WATER CHEMISTRYCHEMISTRY
10
WATER IMPURITIESWATER IMPURITIES
–1 SUSPENDED SOLIDS1 SUSPENDED SOLIDS–22 DISSOLVED SOLIDS DISSOLVED SOLIDS–33 DISSOLVED GASES DISSOLVED GASES
RAW WATER TREATMENT - WATER RAW WATER TREATMENT - WATER CHEMISTRYCHEMISTRY
11
SUSPENDED SOLIDS: SUSPENDED SOLIDS: COMPOSITIONCOMPOSITION• LARGE PARTICLES – GRIT, SAND, ORGANICS
LARGER THAN 1 MICRON
• SMALL PARTICLES - TURBIDITY DUE TO CLAY, SAND, SILT, ORGANICS ETC. 0.5 TO 1 MICRON
• COLLIODAL PARTICLES - GENERALLY OF SILICA LESS THAN 1 MICRON
RAW WATER TREATMENT - WATER RAW WATER TREATMENT - WATER CHEMISTRYCHEMISTRY
12
SUSPENDED SOLIDS:SUSPENDED SOLIDS: EFFECTS EFFECTS RAW WATER TREATMENTRAW WATER TREATMENT
• SOLIDS PRESENT IN PROCESS USE CREATE VARIETY OF PROBLEMS.
• FOULING OF ION EXCHANGE RESINS & RO.
• DEPOSITS IN HEAT EXCHANGER TUBES AFFECTING HEAT TRANSFER & CAUSING CORROSION.
• POTENTIAL FOR RADIATION EXPOSURE IN NUCLEAR SECONDARY SYSTEMS
• INCREASED BOILER & COOLING TOWER BLOWDOWN
13
RAW WATER TREATMENTRAW WATER TREATMENT
TREATMENT OF TREATMENT OF WATER WATER
IMPURITIESIMPURITIES
14
RAW WATER TREATMENTRAW WATER TREATMENT
RAW WATER TREAT MENT MAINLY COMPRISE OF REMOVAL OF SUSPENDED SOLIDS, COLOR, BIOLOGICAL CONTAMINATION, ETC.
15
MAIN PROCESSES:MAIN PROCESSES:RAW WATER TREATMENTRAW WATER TREATMENT
• CLARIFICATION
– SETTLE OUT THOSE LARGER SUSPENDED PARTICLES THAT ARE READILY SETTLEABLE.
– CONDITION SMALLER MAKING THEM FILTERABLE
• FILTRATION
• SLUDGE HANDLING
• DISINFECTION
16
REMOVAL OF SUSPENDED SOLIDS:REMOVAL OF SUSPENDED SOLIDS:
RAW WATER TREATMENTRAW WATER TREATMENT
• LARGE PARTICLES– THESE CAN BE SETTLED IN SEDIMENTATION
BASINS IN THE FORM OF RESERVOIR OR TANK.
• SMALL PARTICLES– REMOVAL OF SMALL PARTICLES REQUIRE
CLARIFICATION EQUIPMENT.
17
RAW WATER TREATMENTRAW WATER TREATMENT
COAGULATICOAGULATIONON
18
CLARIFYING SYSTEM: CLARIFYING SYSTEM: COAGULATIONCOAGULATION
RAW WATER TREATMENTRAW WATER TREATMENT
• THE KEY TO CLARIFICATION IS THE ADDITION OF CHEMICALS TO AGGLOMERATE SMALL SUSPENDED SOLIDS SHORTENING THEIR SETTLEMENT TIME.
• THE PRIMARY FACTOR IS ELECTRICAL CHARGE. ALL PARTICLES OF TURBIDITY & COLOR HAVE USUALLY NEGATIVE ELECTRICAL SURFACE CHARGE.
19
CLARIFYING SYSTEM: CLARIFYING SYSTEM: COAGULATIONCOAGULATIONRAW WATER TREATMENTRAW WATER TREATMENT
• THE SIGN OF PARTICLE ELECTRICAL CHARGE & MAGNITUDE ARE AFFECTED BY THE pH & IONIC CONTENT OF THE SURROUNDING WATER.
• THIS (-VE ) CHARGE ATTRACTS A COMPACT LAYER OF OPPOSITE CHARGED IONS (COUNTER IONS) IN A VERY CLOSE FORM & MORE DIFFUSE LAYER FURTHER AWAY.
• THE ABOVE LAYER COMBINATION CREATES ELECTROSTATIC POTENTIAL THAT REPELS OTHER SIMILAR CHARGED PARTICLES.
20
21
22
CLARIFYING SYSTEM: CLARIFYING SYSTEM: COAGULATIONCOAGULATIONRAW WATER TREATMENTRAW WATER TREATMENT
• CHEMICALS CALLED COAGULANTS ARE ADDED TO BREAKDOWN THIS BARRIER BY INTRODUCING OPPOSITE (+VE) .
• COAGULANTS ARE METALLIC SALTS THAT INTRODUCE +VE METAL IONS CARRYING TWO OR MORE ELECTRICAL CHARGES.
• THIS INCREASES THE CONCENTRATION OF COUNTER IONS IN THE DIFFUSE LAYER THUS THE REPULSIVE FORCE IS REMOVED THAT ALLOWS THE PARTICLES TO COME IN CONTACT.
23
CLARIFYING SYSTEM:CLARIFYING SYSTEM: COAGULATION COAGULATIONRAW WATER TREATMENTRAW WATER TREATMENT
• ALUM (ALUMIMIUM SULPHATE IS THE MOST WIDELY USED COAGULANT)
• IN ADDITION TO NEUTRALIZING THE ELECTROSTATIC BARRIER THEY REACT WITH ALAKLINITY OF THE WATER TO FORM A TOUGH ALUMINIUM HYDROXIDE “FLOC” WHICH IS STABLE OVER pH RANGE 5.7-7.5.
• IRON SALTS LIKE FeCl3 PRECIPTATE HYDROXIDE FLOC OVER MUCH BROADER RANGE 5 TO 11 HENCE ARE USEFUL IN LIME SOFTENING PLANTS.
24
25
CLARIFYING SYSTEM: CLARIFYING SYSTEM: COAGULATIONCOAGULATIONRAW WATER TREATMENTRAW WATER TREATMENT
• ALUM HYDROLIZING REACTION RELEASES SULPHURIC ACID THAT REACTS WITH ALKALINTY FORMING CaSO4 & CO2.
• EACH ppm OF ALUM USED BRINGS DOWN THE ALKALINITY BY 0.45 ppm. THUS TO COUNTERACT THIS EFFECT 0.4 ppm OF LIME (90% CaO) PER ppm OF ALUM IS ADDED OR 0.5 ppm OF SODA ASH PER ppm OF ALUM.
26
CLARIFYING SYSTEM: CLARIFYING SYSTEM: COAGULATIONCOAGULATIONRAW WATER TREATMENTRAW WATER TREATMENT
• SODIUM ALUMINATE IS SLIGHTLY ALKALINE. USEFUL TO ADD WITH LOW Ph WATERS REDUCING THE CONSUMPTION OF LIME NEEDED FOR SOFTENING.
• THE QUANTITY OF ANY COAGULANT IS ACTUALLY IS CLOSELY CONTROLLED TO GIVE THE OPTIMUM pH FOR BEST COAGULATION.
27
RAW WATER TREATMENTRAW WATER TREATMENT• OPTIMUM DOSAGE OF CHEMICALS VARY WITH
– SUSPENDED PARTICLE SIZE & CONCENTRATION
– DETENTION TIME BEFORE COAGULATION
– WATER TEMPERATURE
– AMOUNT OF MIXING ETC.
• IN VIEW OF THE ABOVE IT IS EXTREMLY DIFFICULT TO PREDICT THE DOSAGES.
• IN PRACTICE IT IS BASED ON JAR TESTS ON THE WATER IN USE.
CLARIFYING SYSTEM:- COAGULATIONCLARIFYING SYSTEM:- COAGULATION
28
CLARIFYING SYSTEM:- COAGULATIONCLARIFYING SYSTEM:- COAGULATIONRAW WATER TREATMENTRAW WATER TREATMENT
• JAR TEST SHOULD BE RUN AT LEAST ONCE IN A MONTH OR WHENEVER THERE IS APPRCIABLE CHANGE IN WATER QUALITY.
• AS GUIDE, THE UPPER 100 mm IN A SAMPLE SHOULD BECOME CLEAR IN 2-4 MINUTES.
• WATER WITH LOW TURBIDITY MAY BE MORE DIFFICULT TO COAGULATE THAN THAT WITH HIGH TURBIDITY.
29
CLARIFYING SYSTEM:- COAGULATIONCLARIFYING SYSTEM:- COAGULATIONRAW WATER TREATMENTRAW WATER TREATMENT
………….…………..
…………..
…………..
………….
………….…………..…………..………….………….…………..
…………..
…………..
…………..…………..
………….
………….………….
………….…………..………….…………..………….…………..…………..………….…………. …………..………….…………..………….…………..…………..…………..………….………….………….
JAR TEST
Test Beakers
Drive Motor
30
RAW WATER TREATMENTRAW WATER TREATMENTCOAGULANT COAGULANT
AIDS AIDS USE OF USE OF
POLYMERSPOLYMERS
31
CLARIFYING SYSTEM: CLARIFYING SYSTEM: USE OF POLYMERSUSE OF POLYMERSRAW WATER TREATMENTRAW WATER TREATMENT
• POLYMERS ARE USED TO ENHANCE COAGULATION BY GROWING FLOC SIZE.
• THESE ARE POLYELCTROLYTES – SYNTHETIC ORGANIC POLYMERS OF HIGH MOLECULAR WEIGHTS CONTAINING CHEMICALS GROUPS THAT CAN INTERACT WITH SURFACE SITES ON COLLOIDAL PARTICLES.
• THESE ACT WITH EXTREMELY HIGH SPEED ENLARGING THE FLOC SIZE THUS IMPROVING SETTLEMENT.
32
CLARIFYING SYSTEM: CLARIFYING SYSTEM: USE OF POLYMERSUSE OF POLYMERSRAW WATER TREATMENTRAW WATER TREATMENT
• POLYMERS ARE EITHER CATIONIC (+veLY CHARGED) OR ANIONIC (-veLY CHARGED) OR NONIONIC.
• SLIGHTLY ANIONIC POLYMER ARE NORMALLY EFFECTIVE. ONCE AGAIN JAR TEST IS NEEDED TO MAKE THE BEST CHOICE.
• SOMETIMES FOR LESS TURBID WATERS A CATIONIC POLYMER MAY ACT AS PRIMARY COAGULANT.
33
CLARIFYING SYSTEM: CLARIFYING SYSTEM: FLOCCULATIONFLOCCULATIONRAW WATER TREATMENTRAW WATER TREATMENT
• FLOCCULATION IS SLOW STIRRING OF COAGULATED PARTICLES TO ENHANCE THE PARTICLE GROWTH
• NORMAL RETENTION TIMES ARE 20 TO 30 MINUTES
• FLOCCULATING TANKS CAN BE EXTERNAL OR INSIDE CLARIFIER
34
Particle in suspension
Polymer molecule
Agglommerated solids
RAW WATER TREATMENTRAW WATER TREATMENTPOLYMER AID ACTION
35
RAW WATER TREATMENTRAW WATER TREATMENT
CLARIFYINGCLARIFYINGEQUIPMENTEQUIPMENT
36
CLARIFYING SYSTEM: CLARIFYING SYSTEM: CLARIFYING EQUIPMENTCLARIFYING EQUIPMENTTHERE ARE NUMBER OF TYPES AND SHAPESTHERE ARE NUMBER OF TYPES AND SHAPESA FEW MOST COMMONLY USED ARE:A FEW MOST COMMONLY USED ARE:
RAW WATER TREATMENTRAW WATER TREATMENT
• CONVENTIONAL
• SOLIDS CONTACT
• SOILDS RECIRCULATION
• TUBE SETTLLER
• LEMELLA PLATE
37
CLARIFYING SYSTEM: CLARIFYING SYSTEM: TYPICAL SURFACE LOADING RATES (mTYPICAL SURFACE LOADING RATES (m33/h/m/h/m22))
RAW WATER TREATMENTRAW WATER TREATMENT
• CONVENTIONAL 1.2 -1.5
• SOLIDS CONTACT *2.5
• SOILDS RECIRCULATION* 2.5
• TUBE SETTLLER1.8
• LEMELLA PLATE (PROJECTED AREA)1.8
* RELATIVE TO SETTLING TANK SURFACE AREA
38
CLARIFYING SYSTEM: CLARIFYING SYSTEM: TYPICAL SURFACE LOADING RATES (mTYPICAL SURFACE LOADING RATES (m33/h/m/h/m22))
RAW WATER TREATMENTRAW WATER TREATMENT
• CONVENTIONAL 1.2 -1.5
• SOLIDS CONTACT *2.5
• SOILDS RECIRCULATION* 2.5
• TUBE SETTLLER1.8
• LEMELLA PLATE (PROJECTED AREA)1.8
* RELATIVE TO SETTLING TANK SURFACE AREA
39
40
41
42
43
44
RAW WATER TREATMENTRAW WATER TREATMENT
SOLIDS SOLIDS CONTACT/RECIRCULCONTACT/RECIRCULATING CLARIFIERSATING CLARIFIERS
45
CLARIFYING SYSTEM:CLARIFYING SYSTEM:SOLIDS RECIRCULATION CLARIFIERSSOLIDS RECIRCULATION CLARIFIERS
RAW WATER TREATMENTRAW WATER TREATMENT
• INDUSTRIAL CLARIFIERS EMPHASIZE ON SOLIDS CONTACT.
• A NUMBER OF DESIGNS ARE AVAILABLE. ACCORDING TO LATEST DEVELOPMENTS SOLIDS RECIRCULATION TYPE ARE MOSTLY PREFERRED DESIGN.
46
CLARIFYING SYSTEM:CLARIFYING SYSTEM:SOLIDS RECIRCULATION CLARIFIERSSOLIDS RECIRCULATION CLARIFIERS
RAW WATER TREATMENTRAW WATER TREATMENT
• SOILD RECICULATION CLARIFIERS COMBINE MIXING, FLOCCULATION AND SETTLING IN ONE TANK.
• INCOMING WATER IS MIXED WITH CHEMICALS & INTIMATE CONTACT WITH RECIRCULATING PRE FORMED SLUDGE IN A REACTION ZONE.
• FROM REACTION ZONE PASSES TO DETENTION ZONE WHERE GENTLE MIXING ENHANCES THE FORMATION OF FLOCS.
47
CLARIFYING SYSTEM:CLARIFYING SYSTEM:SOLIDS RECIRCULATION CLARIFIERSSOLIDS RECIRCULATION CLARIFIERS
RAW WATER TREATMENTRAW WATER TREATMENT
• THE RECIRCULATION RATE DEPENDS ON THE INCOMING WATER TURBIDITY. VARIABLE SPEED IS PROIVDED FOR RECIRCULATING DRIVE FOR THIS PURPOSE.
• CHEMICALS ARE ADDED INTO THE LOWER PORTION OF REACTION ZONE OF THE CLARIFIER. THESE CAN ALSO BE ADDED IN TO THE INCOMING RAW WATER FEED PIPE.
48
CLARIFYING SYSTEM:CLARIFYING SYSTEM:SOILDS RECIRCULATION CLARIFIERSSOILDS RECIRCULATION CLARIFIERS
RAW WATER TREATMENTRAW WATER TREATMENT
• FLOC GETS FULLY DENSIFIED WHEN WATER LEAVES AT BOTTOM, SETTLING RAPIDALLY AS CLEAR WATER RISES.
• DUE TO THIS EFFECT USE OF HIGHER RISE RATES BECOMES POSSIBLE THAT REDUCES THE SIZE OF THE CLARIFIER.
49
50
51
52
53
TROUBLE SHOOTING CLARIFIER (S)
54
55
56
57
58
RAW WATER TREATMENTRAW WATER TREATMENT
FILTRATIFILTRATIONON
59
FILTRATION:FILTRATION:RAW WATER TREATMENT RAW WATER TREATMENT
• FILTRATION COMPLETES THE WORK BEGUN BY CLARIFIERS
• FILTRATION IS BASICALLY A PROCESS OF PLACING A POROUS/PERVIOUS BARRIER ACROSS FLOWING WATER TO REMOVE MATTER HELD IN SUSPENSION.
• IN ITS SIMPLEST FORM CAN BE SURFACE OF THE BARRIER LIKE IN STRAINER OR BY REMOVAL THROUGHOUT THE DEPTH OF MEDIUM.
60
FILTRATION:FILTRATION:RAW WATER TREATMENT RAW WATER TREATMENT
• SURFACE FILTRATION IS LIMITED IN ITS REMOVAL CAPACITY. FOR INDUSTRIAL USE MEDIUM DEPTH IS THE ONLY PRACTICAL SOLUTION.
• GRANULAR MEDIA ARE STANDARD FOR THIS PURPOSE.
• IT FEATURES A BED OF GRADED FINE MEDIA SUPPROTED BY GRAVEL OF DIFFERENT GRADINGS THAT PREVENTS THE PERCOLATION OF FINE FILTERING MEDIA INTO THE COLLECTION SYSTEM.
61
FILTRATION:FILTRATION:RAW WATER TREATMENT RAW WATER TREATMENT
• OVERLYING WATER PERCOLATES THROUGH DOWN THROUGH THE MEDIA & IS COLLECTED AND REMOVED BY THE UNDERDRAIN SYTEM.
• VARIOUS MECHANISMS WORK DURING FILTRATION LIKE SIMPLE ADSORPTION, ELECTROSTATIC EFFECTS, CHEMICAL BRIDGING, OR A COMBINATION.
• THE PHYSICAL CHRACTERISTICS OF THE MEDIUM, FLOW RATE, PARTICLE SIZE, DENSITY, WATER TEMPERATURE AFFECT THE FILTER PERFORMANCE.
62
FILTER MEDIA
FLOCCULATION
SEDIMENTATION
FILTER PORE
STRAINING
WATER BEING FILTERED
INTERCEPTION
FLOC
0.5mm
BACTERIUM 0.001 mm
63
64
CROSS SECTION THROUGH SINGLE MEDIA UNSTRATIFIED BED
CROSS SECTION THROUGH SINGLE MEDIA STRATIFIED BED
CROSS SECTION THROUGH DUAL MEDIA STRATIFIED BED
CROSS SECTION THROUGH TRI MEDIA STRATIFIED BED
GRAIN SIZE GRAIN SIZE
GRAIN SIZE GRAIN SIZE
65
MEDIA PROPERTIES & SIZE:MEDIA PROPERTIES & SIZE:RAW WATER TREATMENT RAW WATER TREATMENT
• NATURAL SILICA SAND SP. GR.- 2.65.
• CRUSHED ANTHRACOAL SP. GR. 1.6 – 1.75
• ACTIVATED CARBON SP. GR. 0.4 – 0.7
• CRUSHED GARNET SP. GR. 4.1 TO 4.6
• MEDIA ARE SPECIFIED BY THE EFFECTAIVE SIZE AND UNIFORMITY COEFFICIENT.
• COMMERCIAL SCREENING IS UNIFORMITY COEFFICIENT 1.6 TO 1.7.
66
GRAIN SIZE
EFFECTIVE SIZE – d10 FOR WHICH 10% SAMPLE IS FINERUNIFORMITY COEFFICIENT – THE RATIO OF d60 FOR WHICH
60% SAMPLE IS FINER TO THE d10
67
BED DEPTH COMBINATIONS:BED DEPTH COMBINATIONS:RAW WATER TREATMENT RAW WATER TREATMENT
• 0.4-0.6 mm SAND 250-300 mm
• 1.0-1.2 mm SAND 600-900 mm
• 0.8-1.0 mm ANTHRACITE 300-600 mm
• 1.4-1.6 mm SAND/ANTHRACITE 750-900 mm
• 1.6-1.8 mm SAND/ANTHRACITE 900-1100 mm
• 2.0-4.0 mm SAND/ANTHRACITE 1250-1500 mm
68
RAW WATER TREATMENTRAW WATER TREATMENTPRESSUPRESSURERE
FILTERSFILTERS
69
VERTCAL PRESSURE MEDIA FILTER
FEATURESFEATURES
•BOTTOM MEDIA SUPPORT AND COLLECTION /DISTRIBUTION SYSTEM.
•FRONTAL PIPEWORK WITH ARRANGED NEST OF VALVES.
•INSTRUMENTATION.
•INLET OUTLET CONNECTIONS.
•VERTICAL CYLINDERICAL VESSEL INSIDE SUITABLY PROTECTED.
RAW WATER TREATMENT RAW WATER TREATMENT
BED PLATE
STRAINER
70
71
72
73
RAW WATER TREATMENTRAW WATER TREATMENTGRAVITGRAVITYY
FILTERSFILTERS
74
75
RAW WATER TREATMENT RAW WATER TREATMENT
SERVICE RUN GRAVITY FILTERS.
• DECLINING FLOW RATE.
• CONSTANT FLOW RATE.
GENERAL FILTER OPERATIONGENERAL FILTER OPERATION
76
RAW WATER TREATMENT RAW WATER TREATMENT
BACKWASH.
• DRAIN.
• AIR SCOUR.
• SETTLE
• BACKWASH WITH FILTERED WATER
• RINSE
GENERAL FILTER OPERATIONGENERAL FILTER OPERATION
77
78
GENERAL FILTER OPERATION GENERAL FILTER OPERATION PROBLEMS:PROBLEMS:
RAW WATER TREATMENT RAW WATER TREATMENT
EFFELUENT QUALITY.
• PARTICLE SIZE LESS THAN 10-20 MICRON NEED SOME MEANS OF FLOCCULATION.
• ACTIVATED SLUDGE PROCESS AND TRICKLING FILTERS HAVE 10-40% BY WEIGHT PARTICLE SIZE < 20 MICRON. IN THIS SIZE RANGE 60-90% REMOVAL IS OBTAINED.
79
GENERAL FILTER OPERATION GENERAL FILTER OPERATION PROBLEMS:PROBLEMS:
RAW WATER TREATMENT RAW WATER TREATMENT
SHORTER FILTER RUNS.
• INCREASE FILTRATION RATE
• CHANGE MEDIA GRAIN SIZE. FOR BIOLGICAL WASTE WATERS MEDIA GRAIN EFFECTIVE SIZE UP TO 2.5 mm CAN PROVIDE SATISFACTORY REMOVAL. RUN LENGTH CAN INCREASE 2 TO 3 TIMES THAN THAT WITH CONVENTIONAL 1.0 -2.0 mm. HOWEVER NEEDS CAREFUL STUDIES.
• INCREASE ALLOWABLE HEAD LOSS
80
GENERAL FILTER OPERATION GENERAL FILTER OPERATION PROBLEMS:PROBLEMS:
RAW WATER TREATMENT RAW WATER TREATMENT
INEFFECTIVE MEDIA CLEANING & MUDBALL FORMATION.
• INSUFFICIENT BACKWASH FLOWS.
• PROGRESSIVELY MEDIA MAY GET COATED DUE TO INSUFFICIENT CLEANING OR PRESENCE OF GREASE ETC. IN WASTE WATERS. THIS GROWTH ON MEDIA GRAINS LEADS TO MUDBALLING. CHLORINATION AND PROPER BACKWASH REGIME SHOULD BE FOLLOWED.
81
GENERAL FILTER OPERATION GENERAL FILTER OPERATION PROBLEMS:PROBLEMS:
RAW WATER TREATMENT RAW WATER TREATMENT
PLUGGED MEDIA SUPPORT SYSTEMS.• KEEP BACK WASH STORAGE WATER CLEAN.
• SELECT SUFFICIENT OPENING SIZE.
• ENSURE PROPER DISINFECTION OF INFLUENT AND BACKWASH WATER.
• AVOID SURGE OF WATER OR AIR INTO THE BACK WASH FLOWS.
82
GENERAL FILTER OPERATION GENERAL FILTER OPERATION PROBLEMS:PROBLEMS:
RAW WATER TREATMENT RAW WATER TREATMENT
MEDIA LOSS.• KEEP OPTIMUM BACK WASH FLOW RATE.
• KEEP MEDIA FREE FROM BIO FOULING SINCE ANY GROWTH AROUND GRAINS CAN REDUCE THEIR NET DENISTY.
• AVOID SURGE OF WATER OR AIR INTO THE BACK WASH FLOWS.
83
RAW WATER TREATMENTRAW WATER TREATMENTSLUDGSLUDGE E
HANDLIHANDLINGNG
84
SLUDGE HANDLING/TREATMENT:SLUDGE HANDLING/TREATMENT:RAW WATER TREATMENT RAW WATER TREATMENT
TYPICALLY COMPRISE.
• SLUDGE REMOVAL, COLLECTION & STORAGE.
• SLUDGE THICKENING.
• SLUDGE CONDITIONING.
• SLUDGE DEWATERING/DRYING RENDERING FOR TRANSPORTATION.
85
86
87
88
89
90
PLANT PLANT DATADATA
KURIMAT POWER STATIONKURIMAT POWER STATION
91
PLANT OVERVIEW:PLANT OVERVIEW: