Download - PRESSURE AND LEVEL MONITOR VERSION
Software rel. 2.3.x
PRESSURE AND LEVEL MONITOR VERSION
2
CONTENTS
● Legendofsymbols.....................................................................................................3INTRODUCTION ............................................................................................................4 Productdescription....................................................................................................4INTENDED USE .............................................................................................................4CONTENT OF THE PACKAGE .....................................................................................4PRECAUTIONS .............................................................................................................4RISKS AND PROTECTIONS BEFORE ASSEMBLY ....................................................5 Positioning..................................................................................................................5 Powersupplyandsensorconnection........................................................................5ASSEMBLY DIAGRAMS ...............................................................................................6CONTROLS IN THE MENU ...........................................................................................7 Firstswitchingon.......................................................................................................7 Controlsinthemenu..................................................................................................8 Workparameters........................................................................................................9MENU STRUCTURE ....................................................................................................10PRELIMINARY SETUP FOR USE ............................................................................... 11 Alarms...................................................................................................................... 11 Sensors....................................................................................................................14 Flowmetercalibration (TOBEUSEDFORAUTOMATICTANKCALIBRATIONONLY).............................15 Tank..........................................................................................................................18 Tankcalibration........................................................................................................19 Load/Savetank........................................................................................................23 Language.................................................................................................................25 Unitsofmeasurement..............................................................................................26 Displaycontrast........................................................................................................28 Alarmtones..............................................................................................................29 Keytones..................................................................................................................29 Operatingmode.......................................................................................................30 Setupmanagement..................................................................................................31 Testmenu.................................................................................................................33USE ..............................................................................................................................35MAINTENANCE / DIAGNOSTICS / REPAIRS ............................................................36 Troubleshooting........................................................................................................36END OF LIFE DISPOSAL ............................................................................................36TECHNICAL DATA ......................................................................................................37 Devicetechnicaldata...............................................................................................37 Setupmenu..............................................................................................................38GUARANTEE TERMS .................................................................................................39
3
● Legendofsymbols
= Genericdanger
= Warning
This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.
4
INTRODUCTION
Productdescription
VISIOisaverycompactandaccuratetop-notchmultifunctiondisplay,abletodisplayanykindofinformationconcerningagriculturaltreatments.Operatorcanselecttherequiredfunctionviasoftware.Itcandisplayseveraltypesofvalues,whichchangeaccordingtosetoperatingmodeandtypeofconnectedsensors.
INTENDED USE
This device is designed towork onagriculturalmachinery for spraying and cropsprayingapplications.ThemachineisdesignedandbuiltincompliancewithENISO14982standard(Electromagneticcompatibility-Forestryandfarmingmachines),harmonizedwith 2014/30/UEDirective.
CONTENT OF THE PACKAGE
ThetablebelowindicatesthecomponentsthatyouwillfindintheVISIOpackage:
Legend:
1 VISIO2 Fixingkit3 Instructionmanual (onCD-ROM)4 Installationsheet
PRECAUTIONS
•Donotaimwaterjetsattheequipment.•Donotusesolventsorfueltocleanthecaseoutersurface.•Donotcleanequipmentwithdirectwaterjets.•Complywiththespecifiedpowervoltage(12VDC).•Incaseofvoltaicarcwelding,removeconnectorsfromVISIOanddisconnectthepowercables.•OnlyuseARAGgenuinesparepartsandaccessories.
P o w e r c a b l e ,s e n s o r s a n dconnection cablesto be connectedto VISIO must beorderedseparately.
5
RISKS AND PROTECTIONS BEFORE ASSEMBLY
Allinstallationworksmustbedonewithbatterydisconnected,usingsuitabletoolsandanyindividualprotectionequipmentdeemednecessary.
Positioning
1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and athands' reach, but away from any moving organs.2) Secure VISIO to rail and push downuntil locked in place.3) Fasten wiring so that it does notinterfere with any moving parts.
Powersupplyandsensorconnection
Sensorsandpowersupplymustbeinstalledandconnectedbyqualifiedpersonnel.VISIOmustbeexclusivelyconnectedtoARAGequipment.WHENARCWELDINGISREQUIRED,MAKESURETHATEQUIPMENTPOWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF NEEDED.ARAGisnotliablefordamagetothesystem,persons,animalsorpropertycausedbyVISIOwrongorunsuitableassembly.Failuretoobservetheaboveinstructionsautomaticallyvoidsthewarranty.
Wirecolor (powercable) Connectionof
red positive
black negative
green countingabort-groundconnection
yellow countingabort-connection+12VDC
power supplysensors
6
ASSEMBLY DIAGRAMS
+12Vdc
GND
Counting abortGround
connection(green wire)
Counting abortConnection
+12VDC
(yellow wire)
* Ifyouwishtocalibratetankautomatically(seerelevantparagraph),temporarilyconnectaflowmeteratsensor2inlet.Oncecalibrationiscompleted,connectionwithpressuresensorshallberestored.
Legend:
1)Powercable2)Connectioncablefordoublesensor3)Flowmeter*4)Pressuresensor5)Levelsensor
7
CONTROLS IN THE MENU
Firstswitchingon
Atfirstswitchingon,VISIOwillrunaguidedprocedureallowingusertosetthedevice'sbasicsettings.
Press toscrollthroughitems,OKtosaveandmoveontonextsetting,orESCtogobacktoprevioussetting.
WARNING:Beforechangingoperatingmode,makesurethatallsensors/flowmetersareDISCONNECTEDfromthedevice.
8
Controlsinthemenu
Inthefollowingpages,accordingtothesetoperatingmode,somemenuitemscouldslightlydifferfromtheshownones.
SWITCHING ONAPressfor1secondBPressthekeyafewtimestoviewthevariousvaluesinextendedmode(ondisplaycentralpart)Everytimethedeviceisswitchedon,itwillshortlyshowapagewiththenameofdeviceandsoftwareversion
SWITCHING OFFAPressfor2seconds
ACCESS TO SETUP MENUFromthemainpage,presskeysatthesametimefor2secondstoopentheSetupMenu
SELECTION AND ACCESS TO MENU ITEMS
APressafewtimestoscrollthroughitems(selecteditemisindicatedbyablackline)BPresstoopentheselectedmenuitem
Thethreedotsunderanitemindicatepresenceofanothersetupmenu
9
EDITING A VALUEAPresstomovethroughdigitsBPressafewtimestoeditthehighlighteddigitCPresstoconfirm.ThedisplaygoesbacktopreviouspageDPresstoexitpagewithoutconfirmingmodification
Editedvaluemustfallwithintherangeshown
Workparameters
0
0% 50%25% 100%75%
0.0 bar
0
0% 50%25% 100%75%
0.0 bar
0% 50%25% 100%75%
0.0 bar
0% 50%25% 100%75% Fromthemainpage,presskeyfortwosecondstoopenWorkParametersmenu,andsetvaluesforLevelcorrection.
10
MENU STRUCTURE
Alarms
Min pressureMax pressureTank reserveMax level
Sensors
Calib. flowmeterMan. calibration
Options
Language
Units of measurem.
Flowrate
VolumelGalm
3
Display contrast
Alarm tones
Keytones
l/minGPMm
3/h
Operating mode
0.0 bar
0.0
0% 50%25% 100%75%
Tank
Capacity
Tank zero value
CalibrationMan. calibrationAuto calibration
Load/Save TankSave tank profileLoad tank profile
Pressure sensorMax pressurePress. zero value
Pressurebarpsi
Setup management
Save setupLoad setup
Test
Firmware versionBattery voltageDisplayKeysSensors
Level / Pressure
11
PRELIMINARY SETUP FOR USE
Alarms
Setthedesiredalarmdisplaythresholds.
Tank reserve alarm
Setthevalueoftheminimumfluidquantityleftinthetank.
1)Opentankreservealarmmenu(Setupmenu>Alarms>Tankreserve).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOKtoedittheselectedmenuitem
2)Todeactivatethealarm,press and
atthesametimeuntilthesetvalue
disappearsandthemessageOFFisdisplayedinstead.Carryoutthesameproceduretoenablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
12
Max tank level
Set themaximumtankcapacitypercentagevaluefor thedesiredalarmactivationthreshold.
1)Opentankmaxlevelmenu(Setupmenu>Alarms>Maxlevel).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
2) Toactivatethealarm,press and
atthesametimeuntilthemessage OFFgoesoffandthealarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
13
Pressure alarms
Setminimumandmaximumpressurethresholdsforalarmmessage.
1)OpenAlarmmenu(Setupmenu>Alarms).
Minimumandmaximumpressurealarmsaresetinthesameway.
Press OK toedittheselectedmenuitem.
2)Toactivatethealarm,press and
keyatthesametimeuntilmessage
OFFgoesoffandpressurealarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.
3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
14
Sensors
1)OpenSensorsmenu(Setupmenu>Sensors).
Themenuitemsdisplayedbelowchangeaccordingtothesetoperationmode:whenmoreitemsareavailable,selectthedesiredoneandpressOKtoeditit.
15
Flowmetercalibration (TOBEUSEDFORAUTOMATICTANKCALIBRATIONONLY)
Duetothedifferentsystemconfigurations(tubes,valves,etc.)ratereadingcouldnotbecorrect.Itisthereforerecommendedtoperformasprayingtest.Ifmeasuredvalueisdifferentfromactualvalue,changetherateconstantthroughanautomaticcalibrationprocedureormanuallycalculatetheconstant.
Manual calibration
Inordertomanuallysetrateconstant,calculateandsetsuitableconstantusingthefollowingformula:
1)Openmanualcalibrationmenu(Setupmenu>Calibration>Man.Calibration).UnderCalibrationmenu,selectMan.Calibration,toviewcurrentlysetconstantvaluebelowtheitem.PressOKtoeditthevalue.
Forflowmeterconstantvalue,refertothecorrespondingmanual.
2)Setflowmeterconstantvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
[quantity measured by equipment]
[actually sprayed quantity]x [constant indicated on flowmeter body]
16
Max. pressure
Setmaximumpressurethatcanbereadbysensor.
1)Opensensormaximumpressuresetting(Setupmenu>Sensors>Pressuresensor>Maxpressure).
Thedisplaywillshowthecurrentsettingbelowtheselecteditem.
Press OK toedittheselectedmenuitem.
2)Setsensormaximumpressure:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
17
Pressure zero value
Setpressuresensorzerovalue.Pressuresensormustberesetwheneversystemstatusandpressuresensorreadingareinconsistent(e.g.pressurereadingwhensystemisstopped).ThepressurezerovaluemustALWAYSbesavedWITHSYSTEMSTOPPED.
1)Openpressuresensorzerosetting(Setupmenu>Sensors>Pressuresensor>Press.zerovalue).
Thedisplaywillshowthecurrentsettingbelowtheselecteditem.
Press OK toedittheselectedmenuitem.
2) PressOK:VISIOwillcalculatethepressuresensorzerovalue,whichwillbeshowninthebottompartofthedisplay(e.g.,4,000mAintheimageontheside).
Ifasensormalfunctionoccurs,themessageCheck sensor!willbeshowninthetoppartofthedisplay.
18
Tank
Fromthismenuitispossibletoviewandsetanumberoftankvalues.-Capacity:thedisplayshowsthemaximumtankcapacityvalue,aspreviouslycalculatedthroughcalibration.Thisvalueisread-only.
Tank zero value
Setlevelsensorzerovalue.Thelevelsensormustberesetinthefollowingcases:1)Iftherearediscrepanciesbetweenthequantityoffluidinthetankandthevaluemeasuredbythelevelsensor(e.g.,fluidpresencedetectedbutemptytank).2)EVERYTIMEacalibrationcurveisuploadedviaUSB.ThetankzerovaluemustALWAYSbesavedWITHANEMPTYTANK.
1)Opentankzerovaluemenu(Setupmenu>Tank>Tankzerovalue).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
2)PressOK:VISIOwillsavethelevelsensorzerovalue,whichwillbeshowninthebottompartofthedisplay(e.g.,3.964mAintheimageontheside).
Ifasensormalfunctionoccurs,themessageCheck sensor!willbeshowninthetoppartofthedisplay.
19
Tankcalibration
Thetankprofilecalibrationcanbecarriedoutinmanualorautomaticmode.Duringcalibration,VISIOwillsaveupto200calibrationpointstocreatethetankprofilecurve.If necessary, the tank profile can be saved and reimported intoVISIO orcompatibleARAGComputers(Bravo180S/300S/400S)atalatertime(e.g.,whenreusingthesametank).Beforestartingtheprocedurecarryoutthefollowingoperations:1)Fill the tankwith cleanwaterWITHOUTADDINGCHEMICALSUBSTANCES.Thetankmustbefull.2)Visuallycheckthereachedlevel.
Automatic tank calibration
1)Openautomaticcalibrationmenu(Setupmenu>Tank>Autocalibration).Press OK toedittheselectedmenuitem.
2)Setthetankmaximumcapacityvalue,i.e.,thetheoreticalquantityoffluidthatwaspreviouslyintroduced:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.3)Starttankdraining.Thedisplaywillstartshowingtheincreasingmeasuredfluidquantityvalue(centralareaofthedisplay),theinstantflowratevalue(bottomright),andtheprogressivenumberofmeasuredcalibrationpoints(bottomleft).
Ifasensormalfunctionoccurs,themessageCheck sensor! willbeshowninthetoppartofthedisplay.
20
4) Oncethetankhasbeencompletelydrained,thevalueinthecentralareaofthedisplaywillstopchanging,andthemessageCompl. calib.?willappearinthedisplaytoppart.Press OK for1secondtocompletecalibration.
5) Thedisplaywillgobacktothepreviousmenuandwillshowtheacquiredvalue.Incaseofmeasurementerrors,orifitisnecessarytostopthecalibration,pressESCfor2secondstoquitthecalibrationprocedurewithoutsaving.Inthiscase,thecurvewillbetheonepreviouslymeasured,orthedefaultcurve.
21
Manual tank calibration
Toperformmanualcalibration,proceedasfollows:1)Calculate thesuitable calibration intervalwith respect to tankmaximumcapacity,bearinginmindthat:-itispossibletosaveupto200calibrationpoints;-ahighnumberofcalibrationpointsmakesformoreaccuratemeasurements.2)Adoptareliablemethodformeasuringthefluidquantitythatwaspreviouslycalculated.Example:
[2000 liters] = maximum tank capacity;[200 points] = set calibration points;[10 liters] * = measurement value in liters.*IMPORTANT:Setameasurementvaluethatisslightlyhigher(e.g.,11liters)thantheformula,inordertomakeupforanyerrorsintheevaluationoftankmaximumcapacity.
1) Openmanualcalibrationmenu(Setupmenu>Tank>Man.Calibration).Press OK toedittheselectedmenuitem.Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.
2)Starttankdraining.Once the measurement container is full, stop draining and, in the display central part, enter the volume of the drained fluid with respect to the previous calibration point:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstoconfirm.
[2000 liters]
[200 points]= [10 liters]
22
ThemessageStabilization willappearinthedisplaytoppartforafewseconds,thenitwillswitchbacktoRec. cal. point.
Thevalueofcalibrationpointswillincreasebyoneunit,andthevalueoftheprogressivelydrainedpartialvolumewillshowthequantityoffluidmeasureduptothatmoment.VISIOisreadyforanewmeasurement.
Itispossibletosavecalibrationpointsobtainedwithdifferentquantitiesofdrainedfluid.
4)Oncethetankhasbeenemptiedcompletely,press OK keyfor1secondtocompletethecalibrationprocessandsavetherelevantcurve.
5) Thedisplaywillgobacktothepreviousmenuandwillshowtheacquiredvalue.Incaseofmeasurementerrors,orifitisnecessarytostopthecalibration,pressESCkeyfor1secondtoquitthecalibrationprocedurewithoutsaving.Inthiscase,thecurvewillbetheonepreviouslymeasured,orthedefaultcurve.
23
Load/Savetank
ThetankcalibrationcanbesavedorloadedontoaUSBpendrive,inordertorestoreitifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallcalibrationoperations.Onceinstallationiscompleted,checkVISIOoperationanditisrecommendedtosavethetankconfigurationonaUSBpendrive.ToloadorsavethecalibrationcurveitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.
1)Opentankconfigurationmenu(Setupmenu>Tank>Load/SaveTank).Press OK toedittheselectedmenuitem.
Load tank profile
AllowstoselectthetankconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.
WARNING:ByloadingtheTANK.TKLfilecontainedintheUSBpendriveontotheVISIO,thecurrenttankprofilewillbelost.
1) Selectcontrolthrough .
2)PressOKtoconfirmloading,orESCtoquitwithoutsaving.
TheTANK.TKLfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.
24
Save tank profile
AllowssavingthetankconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.
1)Selectcontrolthroug .
2) PressOKtoconfirmsaving,orESCtoquitwithoutsaving.
IfaTANK.TKLfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.
25
Language
Setthedesiredlanguage.
Options
Language
English
Units of measurem.
Display contrast
Openlanguagesettingmenu(Setupmenu>Options>Language).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.
PressOK toeditlanguage.
2 1
2
Language
English
ČeskDeutsch
Español
1)Selectalanguagethrough .
2)PressOK tosave,orESC toquitwithoutsaving.
26
Unitsofmeasurement
Setunitofmeasurementforthevaluesdetectedbythedevice.
Flowrate units of measurement
1)Openinstantrateunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Flowrate).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectflowrateunitofmeasurement.
1)Selectaunitthrough .
2)Press OK tosave,orESC toquitwithoutsaving.
Volume units of measurement
1)Openvolumeunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Volume).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectvolumeunitofmeasurement.
1)Selectaunitthrough .
2)Press OK tosave,orESC toquitwithoutsaving.
27
Pressure units of measurement
Openpressureunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Pressure).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectpressureunitofmeasurement.
1) Selectaunitthrough key.
2) PressOKtosave,orESCtoquitwithoutsaving.
28
Displaycontrast
Setdisplaycontrast.
Opendisplaycontrastmenu(Setupmenu>Options>Displaycontrast).
Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.
1)Setavaluethrough .Everytimeyoupressit,valuewillincreaseby5%up
to100%.Usekey todecreasevalue
by5%.2)PressOK tosave,orESC toquitwithoutsaving.
29
Alarmtones
Enable/disablethealarmtones.
Openalarmtonesmenu(Setupmenu>Options>Alarmtones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.
1)Setstatusthrough .
2)PressOK tosave,orESC toquitwithoutsaving.
Keytones
Enable/disablekeytones.
1)Openkeytonesmenu(Setupmenu>Options>Keytones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.
1)Setstatusthrough .
2)PressOK tosave,orESC toquitwithoutsaving.
30
Operatingmode
Setrequiredoperatingmode.
Openoperatingmodemenu(Setupmenu>Options>Operatingmode).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK tochangetheoperatingmode.
1)Selecttherequiredoperatingmode
through .
2)PressOK tosave,orESC toquitwithoutsaving.
WARNING:OnceOKispressed,thepageontwhesidewillbedisplayed.Beforechangingoperatingmode,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmchanges.ConnectthesensorsREQUIREDFORTHE SET OPERATING MODE.
31
Setupmanagement
VISIOsettingscanbeloadedfromorsavedonaUSBpendriveinordertoreconfigureit ifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallmanualoperations.Onceinstallationiscompleted,andVISIOoperationhasbeenchecked,werecommendtosaveallsettingsontoaUSBpendrive.TobeabletousethefollowingfunctionsitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.
1)OpenSetupmanagementmenu(Setupmenu>Setupmanagement).
PressOK toedittheselectedmenuitem.
Load setupAllowstoselectaconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.WARNING:ByloadingtheSETUP.BIN filecontainedintheUSBpendriveontotheVISIO,allcurrentsettingswillbelost.
1)Selectthedesiredcontrolthrough key.2)PressOK toconfirmloading,orESC toquitwithoutsaving.
TheSETUP.BINfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.Ifsetupdownloadinvolveschangingoperatingmodeandusingdifferentsensorsthantheonesinuse,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmloading.Reconnectsensors.
32
Save setupAllowssavingVISIOconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.
1)Selectthedesiredcontrolthrough
key.2)PressOK toconfirmsaving,orESC toquitwithoutsaving.
IfaSETUP.BINfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.
33
Testmenu
ThismenuallowsusertoviewsomedataandcarryoutanoperationtestofVISIO:-Firmwareversion:thedisplayshowsthefirmwareversioninstalled.-Batteryvoltage:thedisplayshowsthepowervoltageofthedevice.
Display test
Displaytestchecksthedevicedisplaycorrectoperation.
1)Opendisplaytestmenu(Setupmenu>Test>Display).Press OK toperformthetest.
Allpixelsondisplayareturnedon.PressESCtogobacktopreviouspage.
Keys test
Keystestchecksthedevicekeyscorrectoperation.
Openkeystestmenu(Setupmenu>Test>Keys).
Press OK toperformthetest.
1)Pressanykeyandthecorrespondingdisplayareawillturnon.PressESC toquit:assoonasyouacknowledgetheswitch-ononofthecorrespondingareaonthedisplay,devicewillgobacktopreviouspage.
34
Sensors test
Sensorstestcheckscorrectoperationofthesensorsconnectedtothedevice.
Opensensorstestmenu(Setupmenu>Test>Sensors).
Press OK toperformthetest.
Thedisplaywillshowthecurrentsensorreadingbelowtheselecteditem.1)Severalsensorscouldbedisplayed,dependingonthesetoperatingmode.Inthiscase,selectrequiredsensor
through .
2)PressESCtoquit.
35
USE
Startliquidflowinthesystem.Themainpageshowsthedisplaydividedintothreehorizontalparts:-toppart:theprogressbarshowsthetanklevelinpercentage;-centralpart:thevaluerepresentsthevolumeoffluidinsidethetank;-bottompart:thevalueistheinstantworkpressure.
Pressthe key severaltimestoviewavalueinextendedmodeuntilvalueisondisplaycentralpart.
36
MAINTENANCE / DIAGNOSTICS / REPAIRS
•Cleanonlywithasoftwetcloth.•Donotuseaggressivedetergentsorproducts.•Donotcleanequipmentwithdirectwaterjets.
Troubleshooting
FAULT CAUSE REMEDY
VISIOisoffordoesnotswitchon
Nopowersupply Checkpowercableconnections
DeviceisOFF PresstheONkey
VISIOshowswrongdata
Wrongsetup Checkdisplayeddatasetup
Sensorfault ContactthenearestAssistanceCenterVISIOfault
Fillingpump(ifany)doesnotstart
PumpStopModulenotpowered
Checkpowersupplyconnection
END OF LIFE DISPOSAL
Disposeofthesystemincompliancewiththeestablishedlegislationinthecountryofuse.
37
TECHNICAL DATA
Devicetechnicaldata
Description VISIO
Display GraphicLCD,128x64pixels,back-lighting
Powersupplyvoltage 9÷16Vdc
Protectionagainstshort-circuit •
Protectionagainstpolarityinversion •
Max.frequency 1.2KHz
Analoginputs 4÷20mA
Digitaloutput-Maxcurrent 100mA
Maximumpowerinput(withnosensorsconnected) 160mA
Operatingtemperature -20°C÷70°C-4°F÷+158°F
Storagetemperature -30°C÷80°C-22°F÷+176°F
Size 126x79x66mm
Weight 245g
38
Setupmenu
Data Min. Max. Default UoM Notes
Calib. flowmeter Calibration 1 10000 OFF pls/l --
Alarms
Min.pressure 1.0 100.0 OFF bar Alarmcanbedisabledbysettingvalueto"OFF"
Max.pressure 1.0 100.0 OFF bar Alarmcanbedisabledbysettingvalueto"OFF"
Reservetank 1 1000 50 l/min. Alarmcanbedisabledbysettingvalueto"OFF"
Max.level 1 1000 OFF l/min. Alarmcanbedisabledbysettingvalueto"OFF"
Display Contrast 0 100 50 % --
Options
Language - - English -
Availablelanguages:Italiano,English,Español,Português,Français,Deutsch,Cesky,Polski,Русский,Magyar,ニホン .
Flowrateunitsofmeasurement - - l/min. l/min. Availableunitsofmeasurement:
l/min,GPM,m3/h
Volumeunitsofmeasurement - - l liters Availableunitsofmeasurement:
l,gal,m3
Pressureunitsofmeasurement - - bar bar Availableunitsofmeasurement:
bar,PSI
39
GUARANTEE TERMS
1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateofsaletotheclientuser(dateofthegoodsdeliverynote).Thecomponentsoftheapparatus,thatintheunappealableopinionofARAGarefaultyduetoanoriginaldefectinthematerialorproductionprocess,willberepairedorreplacedfreeofchargeatthenearestAssistanceCenteroperatingatthemomenttherequestforinterventionismade.Thefollowingcostsareexcluded:
- disassemblyandreassemblyoftheapparatusfromtheoriginalsystem;- transportoftheapparatustotheAssistanceCenter.2. Thefollowingarenotcoveredbytheguarantee:- damagecausedbytransport(scratches,dentsandsimilar);- damageduetoincorrectinstallationortofaultsoriginatingfrominsufficientor
inadequatecharacteristicsoftheelectricalsystem,ortoalterationsresultingfromenvironmental,climaticorotherconditions;
- damageduetotheuseofunsuitablechemicalproducts,forspraying,watering,weedkillingoranyothercroptreatment,thatmaydamagetheapparatus;
- malfunctioningcausedbynegligence,mishandling,lackofknowhow,repairsormodificationscarriedoutbyunauthorizedpersonnel;
- incorrectinstallationandregulation;- damageormalfunctioncausedbythelackofordinarymaintenance,suchascleaning
offilters,nozzles,etc.;- anythingthatcanbeconsideredtobenormalwearandtear.3. Repairingtheapparatuswillbecarriedoutwithintimelimitscompatiblewiththe
organizationalneedsoftheAssistanceCenter.Noguaranteeconditionswillberecognizedforthoseunitsorcomponentsthathavenotbeenpreviouslywashedandcleanedtoremoveresidueoftheproductsused;
4. Repairscarriedoutunderguaranteeareguaranteedforoneyear(360days)fromthereplacementorrepairdate.
5. ARAGwillnotrecognizeanyfurtherexpressedorintendedguarantees,apartfromthoselistedhere.NorepresentativeorretailerisauthorizedtotakeonanyotherresponsibilityrelativetoARAGproducts.Theperiodoftheguaranteesrecognizedbylaw,includingthecommercialguaranteesandallowancesforspecialpurposesarelimited,inlengthoftime,tothevaliditiesgivenhere.InnocasewillARAGrecognizelossofprofits,eitherdirect,indirect,specialorsubsequenttoanydamage.
6. ThepartsreplacedunderguaranteeremainthepropertyofARAG.7. Allsafetyinformationpresentinthesalesdocumentsregardinglimitsinuse,
performanceandproductcharacteristicsmustbetransferredtotheenduserasaresponsibilityofthepurchaser.
8. AnycontroversymustbepresentedtotheReggioEmiliaLawCourt.
CONFORMITY DECLARATION
The declaration of conformity is available at www.aragnet.com, in the relevant section.
42048 RUBIERA (Reggio Emilia) - ITALYVia Palladio, 5/ATel. +39 0522 622011Fax +39 0522 [email protected]
Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com
D20
287_
GB
-m04
03/2
017