THE DESIGNER’S ROLE IN
ANTICIPATING & ADDRESSINGCONSTRUCTION HURDLES
Presented by Ashley Rao, AIA LEED AP
Leers Weinzapfel Associates
Disclaimer: This presentation was developed by a third party and is not funded by WoodWorks or the Softwood Lumber Board.
COMMUNITY
INFRASTRUCTUREACADEMIC
CIVIC
MASS TIMBER
ADOHI HALLUNIVERSITY OF ARKANSAS
ADOHI HALLUNIVERSITY OF ARKANSAS
ARCHITECTURE & INTERIOR DESIGN
Leers Weinzapfel Associates
Modus Studio
Mackey Mitchell Architects
LANDSCAPE ARCHITECT
Olin
STRUCTURAL DESIGN
Equilibrium Consulting
Engineering Consultants, Inc
MEP/FP ENGINEERS
Bernhard TME
CIVIL ENGINEERS
Development Consulting, Inc.
SUSTAINABILITY
Entegrity
GRAPHIC DESIGN
Lizzy Lee Studio
CODE
Howe Engineers, Inc.
UNIVERSITY OF ARKANSAS
FACILITIES & PLANNING
UNIVERSITY OF ARKANSAS
HOUSING
UNIVERSITY OF ARKANSAS
FAY JONES SCHOOL OF
ARCHITECTURE
CONSTRUCTION MANAGER
Nabholz Construction
MASS TIMBER SUPPLIER
Binderholz / Holzpak
SITE PLAN
TYPICAL FLOOR PLAN
ANTICIPATINGCONSTRUCTION HURDLES
• CREATE A SHARED FOUNDATION OF KNOWLEDGE
• MAKE COST-EFFECTIVE DESIGN CHOICES
• EVALUATE CODE ISSUES EARLY
• CONSIDER SPECIES/FABRICATOR DIFFERENCES
• LEVERAGE PRE-FABRICATION POTENTIAL
2012 IBC
722.6.3 Design of fire-resistant exposed wood
members. The fire-resistance rating, in minutes, of
timber beams and columns with a minimum nominal
dimension of 6 inches (152 mm) is equal to:
Beams:
2.54Zb [4 -2(b/d)] for beams which may be exposed to
fire on four sides.
(Equation 7-18)
2.54Zb [4 -(b/d)] for beams which may be exposed to
fire on three sides.
(Equation 7-19)
Columns:
2.54Zd [3 -(d/b)] for columns which may be exposed to
fire on four sides
(Equation 7-20)
2.54Zd [3 -(d/2b)] for columns which may be exposed
to fire on three sides.
(Equation 7-21)
where:
b = The breadth (width) of a beam or larger side of a
column before exposure to fire (inches).
d = The depth of a beam or smaller side of a column
before exposure to fire (inches).
Z = Load factor, based on Figure 722.6.3(1).
TYPICAL MEMBER SIZE
SCREWS
TYPICAL MEMBER SIZE
SCREWS
TYPICAL MEMBER SIZE
TYPICAL MEMBER SIZE
SCREWS
COORDINATING PENETRATIONS
COORDINATING PENETRATIONS
PENETRATIONSCOORDINATING PENETRATIONS
ADDRESSINGCONSTRUCTION HURDLES
• PROTECT EXPOSED STRUCTURE
• ACCOMMODATE FIELD TOLERANCES
• ADDRESS NECESSARY FIELD MODIFICATIONS
TIMBER INSTALLATION
TRANSPORT PROTECTIONYARD STORAGE
STRUCTURE AS FINISH MATERIAL
STRUCTURE AS FINISH MATERIAL
STRUCTURE AS FINISH MATERIAL
CONCRETE COORDINATION & SEQUENCING
FIELD ADJUSTMENT MANUALTYPICAL CONNECTION
FIELD ADJUSTMENT MANUALFIELD ADJUSTMENT MANUALIF THE CONCRETE “OPENS”
FIELD ADJUSTMENT MANUALIF THE CONCRETE “CLOSES”
FIELD ADJUSTMENT MANUALFIELD DRILL JIG
MULTI-STORY COLUMN SPAN
STRUCTURE AS FINISH MATERIALFIELD MODIFIED
CORRECTLY INSTALLED
STRUCTURE AS FINISH MATERIAL
This concludes The American Institute of Architects Continuing Education Systems Course
QUESTIONS?
Ashley Rao, AIA LEED AP
Leers Weinzapfel Associates