Transcript
![Page 1: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/1.jpg)
PPPL:CAD Development of Modular CoilsPhase 4Aug 26, 2003
![Page 2: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/2.jpg)
1
1/2” Insulation gap was added between housings
![Page 3: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/3.jpg)
2
20 Degree segment view
![Page 4: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/4.jpg)
180 Degree Segment View
3
![Page 5: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/5.jpg)
4
Step-Up for connecting surfaces
Coil-Housing surfaces need to be brought inward too aid in clearing the adjacent housing
![Page 6: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/6.jpg)
Surface Clearances
5
11
1113
13
Former collision area
Former collision area
![Page 7: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/7.jpg)
Coil - 11
6
![Page 8: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/8.jpg)
Coil - 12
7
![Page 9: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/9.jpg)
Coil - 13
8
![Page 10: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/10.jpg)
Coil 11 - with 2” flange height
9
Extra room for clamps and cooling channel
* Surfaces not developed
![Page 11: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/11.jpg)
10
Coil 12 - with 2” flange height
* Partially developed surfaces
![Page 12: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/12.jpg)
11
Coil 13 - with 2” flange height
* Partially developed surfaces
![Page 13: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/13.jpg)
12
Collision not yet addressed
Simple edge chamfer should make them clear
![Page 14: PPPL: CAD Development of Modular Coils Phase 4](https://reader036.vdocuments.us/reader036/viewer/2022062322/5681505d550346895dbe5e3f/html5/thumbnails/14.jpg)
13
Section views with 2” flange height