![Page 1: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen](https://reader030.vdocuments.us/reader030/viewer/2022040613/5f0835a67e708231d420e10a/html5/thumbnails/1.jpg)
PL3CameraCalibration
1、First,installthecalibrationsoftware"SimpleBGC_GUI_2_40"onyourWindowscomputer.
2、LoosenthetwoscrewsintheredboxbelowandyoucanseetheUSBinterface.UsetheUSB
cabletolinkthecameraandthecomputer.
3、Placethecameraonthehorizontaltableandpressitflatwithyourhand.
4、Runthecameracalibrationsoftware"SimpleBGC_GUI_2_40".Andcompletethecalibration
accordingtothefollowingsteps:
![Page 2: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen](https://reader030.vdocuments.us/reader030/viewer/2022040613/5f0835a67e708231d420e10a/html5/thumbnails/2.jpg)
Table1:Clickonthelabeledredbox,selectCOM66orothermaximumvalues,andclickonthe
connection(BlueArrow)
![Page 3: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen](https://reader030.vdocuments.us/reader030/viewer/2022040613/5f0835a67e708231d420e10a/html5/thumbnails/3.jpg)
Table 2: After the connection is successful, the parameters on the right will change. The
arrow indicates that the connection is successful. Click Load(red rectangle)
Table3:Afterloading,selectfirmwaremarkedwithredboxandselectOpen
![Page 4: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen](https://reader030.vdocuments.us/reader030/viewer/2022040613/5f0835a67e708231d420e10a/html5/thumbnails/4.jpg)
Table4:Selectthewritingoftheredbox,andthearrowinthelowerleftcornerwillshow“从控
制器上成功载入参数”whenthewritingissuccessful.
Table5:clicktheredboxandthearrowinthelowerleftcornerwillshow”加速度计校准开
始”,andthearrowinthelowerrightcornerwillshowaslightchange.
Note:Ifyoucan'tseethevaluejumpinthelowerrightcorner,justwait10secondsforthenext
step.
![Page 5: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen](https://reader030.vdocuments.us/reader030/viewer/2022040613/5f0835a67e708231d420e10a/html5/thumbnails/5.jpg)
Table6:SelectCALIBGYRO,thelowerleftcornerwilldisplaytheEnglishletters,andthelower
rightcornerarrowvaluewilljumpslightly.
Note:Ifyoucan'tseethevaluejumpinthelowerrightcorner,justwait10secondsforthenext
step.
![Page 6: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen](https://reader030.vdocuments.us/reader030/viewer/2022040613/5f0835a67e708231d420e10a/html5/thumbnails/6.jpg)
Table7:ChooseWriting.ThelowerleftcornerofsuccessfulWritingwillshow”当前配置文件成
功写入控制器”
CalibrationiscompletedandpulledoutUSBcable.CheckwhetherPL3cameraworksproperlyby
electrifying.