Learning objectives
To state sub-systems in a measurementsystem
To understand main function in each sub-system
To understand the basic properties ofmeasurement systems
-
7/25/2019 PI2 Measurement
3/37
Basic components in a measurementsystem
Basic components in a measurement system are shown below:
It is also important to mention that a power supply is an important
element for the entire system.
Amplication and !onditioning
-
7/25/2019 PI2 Measurement
4/37
INSTRUMENTATION CHARACTERISTICS
Shows the performance of instruments to beused.
Divided into two categories: static and
dynamic characteristics. Static characteristics refer to the
comparison between steady output and idealoutput when the input is constant.
Dynamic characteristics refer to thecomparison between instrument output andideal output when the input changes.
-
7/25/2019 PI2 Measurement
5/37
STATIC CHARACTERISTICS
1. ACCURACY
Accuracy is the ability of aninstrument to show the exact reading.
Always related to the extent of thewrong reading/non accuracy.
Normally shown in percentage oferror which of the full scale readingpercentage.
-
7/25/2019 PI2 Measurement
6/37
STATIC CHARACTERISTICS
Example :
A pressure gauge with a range between
!" bar with an accuracy of # $% fs&full!scale' has a maximum error of:
$ x " bar ( # .$ bar
"
Notes: )t is essential to choose ane*uipment which has a suitable operatingrange.
-
7/25/2019 PI2 Measurement
7/37
STATIC CHARACTERISTICS
Example :
A pressure gauge with a range between
! " bar is found to have an error of# ."$ bar when calibrated by themanufacturer.
+alculate :
a. ,he error percentage of the gauge.b. ,he error percentage when the
reading obtained is -. bar.
-
7/25/2019 PI2 Measurement
8/37
STATIC CHARACTERISTICS
Answer :
a. Error ercentage ( # ."$ bar x " ( # ".$%
". bar
b. Error ercentage ( # ."$ bar x " ( # .$ % -. bar
,he gauge is not suitable for use for low range
reading. Alternative : use gauge with a suitable range.
-
7/25/2019 PI2 Measurement
9/37
STATIC CHARACTERISTICS
Example :
,wo pressure gauges &pressure gauge A and 0' have afull scale accuracy of # $%. Sensor A has a range of!" bar and Sensor 0 !" bar. 1hich gauge is moresuitable to be used if the reading is .2 bar3
Answer :Sensor A :
E*uipment max error ( # $ x " bar ( # .$ bar
"E*uipment accuracy4 .2 bar & in %' ( # .$ bar x " ( # $.5%
.2 bar
-
7/25/2019 PI2 Measurement
10/37
STATIC CHARACTERISTICS
Sensor 0 :
E*uipment max error ( # $ x " bar ( # .$ bar "
E*uipment accuracy4 .2 bar & in %' ( # .$ bar x " ( # $$%
.2 bar
+onclusion :
Sensor A is more suitable to use at a reading of .2 barbecause the error percentage $.5%' is smaller comparedto the percentage error of Sensor 0 $$%'.
-
7/25/2019 PI2 Measurement
11/37
2. PRECISION
An e*uipment which is precise is notnecessarily accurate.
Defined as the capability of aninstrument to show the same reading
when used each time &reproducibility ofthe instrument'.
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
12/37
STATIC CHARACTERISTICS
Example :6 : result
+entre circle : true value
XXX
XXXX
XXX
XXX
XXX
X X
X
xxHigh accuracy, high precision
Low accuracy, high precision
Low accuracy, low precision
-
7/25/2019 PI2 Measurement
13/37
Accuracy vs Precision
High Precision, but low
accuracy.
There is a systematic error"
-
7/25/2019 PI2 Measurement
14/37
Accuracy vs Precision #!ont$
%igh accuracy means that the mean is close to the truevalue& 'hile high precision means that the standarddeviation ( is small"
-
7/25/2019 PI2 Measurement
15/37
3. TOLERANCE
+losely related to accuracy of an
e*uipment where the accuracy of ane*uipment is sometimes referred to inthe form of tolerance limit.
Defined as the maximum error
expected in an instrument. Explains the maximum deviation of an
output component at a certain value.
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
16/37
4. RANGE OF SPAN
Defined as the range of reading between
minimum value and maximum value forthe measurement of an instrument.
7as a positive value e.g..:
,he range of span of an instrumentwhich has a reading range of 8"9+ to" 9+ is - 9+.
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
17/37
. !IAS
+onstant error which occurs during themeasurement of an instrument.
,his error is usually rectified through calibration.
Example :
A weighing scale always gives a bias reading. ,hise*uipment always gives a reading of " g even
without any load applied. ,herefore; if A with aweight of g weighs himself; the given readingwould be " g. ,his would indicate that there isa constant bias of " g to be corrected.
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
18/37
". LINEARITY
-
7/25/2019 PI2 Measurement
19/37
L#near#t$
)utput*eadings
Measured +uantity
-
7/25/2019 PI2 Measurement
20/37
%. SENSI&ITY
Defined as the ratio of change in output towardsthe change in input at a steady state condition.
Sensitivity &>' ( ?@
?@i
?@: change in outputB ?@i : change in input
Example ":
,he resistance value of a latinum Cesistance,hermometer changes when the temperatureincreases. ,herefore; the unit of sensitivity forthis e*uipment is hm/9+.
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
21/37
,ensitivity
&ar#at#'n '( t)e *)$s#+a, -ar#a,es
Most sensitive
-
7/25/2019 PI2 Measurement
22/37
STATIC CHARACTERISTICS
Example -:
ressure sensor A with a value of - barcaused a deviation of " degrees.
,herefore; the sensitivity of thee*uipment is $ degrees/bar.
Sensitivity of the whole system is &' (" x - x E x .. x n
1 . /0i0o
-
7/25/2019 PI2 Measurement
23/37
STATIC CHARACTERISTICS
Example:
+onsider a measuring system consisting of a transducer; amplifierand a recorder; with sensitivity for each e*uipment given below:
,ransducer sensitivity .- mF/9+
Amplifier gain -. F/mFCecorder sensitivity $. mF/F
,herefore;
Sensitivity of the whole system:
&' ( " x - x E ( .- mF x -. F x $. mF
9+ mF F
( -. mF/9+
-
7/25/2019 PI2 Measurement
24/37
Example :
,he output of a platinum resistance thermometer&C,D' is as follows:
+alculate the sensitivity of the e*uipment.
Answer :
Draw an input versus output graph. Grom that graph;the sensitivity is the slope of the graph.
> ( ?@ graph ( &H!-' ohm ( - ohm/9+?@i slope &-!"' 9+
nput#2!$ )utput#)hm$
3 3
133 .33
.33 433
/33 533
433 633
-
7/25/2019 PI2 Measurement
25/37
/. 0EA0 SPACE 0EA0 !AN0
Defined as the range of input reading when thereis no change in output &unresponsive system'.
Dead Space
)utput*eading
Measured7ariables
- +
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
26/37
. RESOLUTION
,he smallest change in input readingthat can be traced accurately.
Iiven in the form J% of full scale&% fs'K.
Available in digital instrumentation.
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
27/37
1. THRESHOL0
1hen the reading of an input isincreased from Lero; the input readingwill reach a certain value beforechange occurs in the output.
,he minimum limit of the input readingis JthresholdK.
STATIC CHARACTERISTICS
-
7/25/2019 PI2 Measurement
28/37
0YNAMIC CHARACTERISTICS
Explains the behaviour system ofinstruments system when the inputsignal is changed.
Depends on a few standard inputsignals such as Jstep inputK; JrampinputK dan Jsine!wave inputK.
-
7/25/2019 PI2 Measurement
29/37
0YNAMIC CHARACTERISTICS
Step )nput
Sudden change in input signal from steadystate.
,he output signal for this ind of input isnown as Jtransient responseK.
nput
Time
-
7/25/2019 PI2 Measurement
30/37
0YNAMIC CHARACTERISTICS
Camp )nput ,he signal changes linearly.
,he output signal for ramp input isJramp responseK.
nput
Time
-
7/25/2019 PI2 Measurement
31/37
0YNAMIC CHARACTERISTICS
Sine!wave )nput
,he signal is harmonic.
,he output signal is Jfre*uency responseK.
nput
Time
-
7/25/2019 PI2 Measurement
32/37
*esponse time
)ne 'ould lie to have ameasurement system 'ithfast response"
n other 'ords& the e8ect ofthe measurement system onthe measurement should be
as small as possible"
-
7/25/2019 PI2 Measurement
33/37
EAMPLE OF 0YNAMICCHARACTERISTICS
Cesponse from a -ndorder instrument:)utput
100%
90%
10%
trTime
-
7/25/2019 PI2 Measurement
34/37
EAMPLE OF 0YNAMICCHARACTERISTICS
Cesponse from a -ndorder instrument:
". Cise ,ime & tr '
,ime taen for the output to rise from"% to 2 % of the steady state value.
-. Settling time &ts'
,ime taen for output to reach a steady
state value.
, f
-
7/25/2019 PI2 Measurement
35/37
,ensor Performance!haracteristics
Trans(er Fun+t#'n5
The functional relationship bet'een physical input signal and electrical outputsignal" 9sually& this relationship is represented as a graph sho'ing therelationship bet'een the input and output signal& and the details of thisrelationship may constitute a complete description of the sensorcharacteristics" or e;pensive sensors 'hich are individually calibrated& this
might tae the form of the certied calibration curve"Sens#t#-#t$5
The sensitivity is dened in terms of the relationship bet'een input physicalsignal and output electrical signal" The sensitivity is generally the ratiobet'een a small change in electrical signal to a small change in physicalsignal" As such& it may be e;pressed as the derivative of the transfer function
'ith respect to physical signal" Typical units : &',ts6e,-#n" A Thermometer'ould have
-
7/25/2019 PI2 Measurement
36/37
,ensor Performance!haracteristics
A++ura+$5=enerally dened as the largest e;pected error bet'een actual and idealoutput signals" Typical 9nits : >elvin" ,ometimes this is ?uoted as a fraction ofthe full scale output" or e;ample& a thermometer might be guaranteedaccurate to 'ithin @ of ,) #ull ,cale )utput$
H$steres#s5
,ome sensors do not return to the same output value 'hen the input stimulusis cycled up or do'n" The 'idth of the e;pected error in terms of themeasured ?uantity is dened as the hysteresis" Typical units : >elvin or of,)
N'n,#near#t$ 8'(ten +a,,e9 L#near#t$:5
The ma;imum deviation from a linear transfer function over the specieddynamic range" There are several measures of this error" The most commoncompares the actual transfer function 'ith the best straight lineC& 'hich liesmid'ay bet'een the t'o parallel lines 'hich encompasses the entire transferfunction over the specied dynamic range of the device" This choice ofcomparison method is popular because it maes most sensors loo the best"
, P f
-
7/25/2019 PI2 Measurement
37/37
,ensor Performance!haracteristics
N'#se5All sensors produce some output noise in addition to the output signal" Thenoise of the sensor limits the performance of the system based on the sensor"Doise is generally distributed across the fre?uency spectrum" Many commonnoise sources produce a 'hite noise distribution& 'hich is to say that thespectral noise density is the same at all fre?uencies" ,ince there is an inverse
relationship bet'een the band'idth and measurement time& it can be saidthat the noise decreases 'ith the s?uare root of the measurement time"
Res',ut#'n5
The resolution of a sensor is dened as the minimum detectable signalEuctuation" ,ince Euctuations are temporal phenomena& there is somerelationship bet'een the timescale for the Euctuation and the minimum
detectable amplitude" Therefore& the denition of resolution must includesome information about the nature of the measurement being carried out"
!an9;#9t)5
All sensors have nite response times to an instantaneous change in physicalsignal" n addition& many sensors have decay times& 'hich 'ould represent
the time after a step change in ph sical signal for the sensor output to deca