Page 1: Permanent Reservoir / Water Zone Monitoring · up to 6 points of temp monitoring with a single 0.25” line Features & Benefits Permanent real-time downhole monitoring system can

BGES provides reliable permanent subsurface pressure and temperature monitoring options for optimal reservoir and/or water zone measurements.

The permanent monitoring system is installed in the well as an integral part of the completion. Its durable components are able to withstand extreme temperature conditions for long-term applications.

Downhole sensors include:

Piezo – cost-effective and rugged Quartz – high accuracy Piezometer – high temperature Thermocouple – high temperature multi-point RTD – precise temperature monitoring

Appl ica t ions Pressure/temperature monitoring for SAGD

plants (Injector / Producer Monitoring) CO2 storage caverns or other types of storage

wells Coalbed methane for fluid level monitoring and

pump protection Observation, production or injection wells Aquifer monitoring

Various high-temp monitoring applications — up to 6 points of temp monitoring with a single 0.25” line

Features & Benef i ts Permanent real-time downhole monitoring system can transmit 24x7 real-time pressure and temperature data to your desktop via DCS, SCADA

Re

serv

oir/C

ap

roc

k T

estin

g &

Da

ta A

cq

uisitio

n

Permanent Reservoir / Water Zone Monitoring

(4-20mA) or wireless.

Gauges are constructed with SS316 or Hastelloy C-276 to withstand severe operating conditions.

Solar power option is available.

Operat ion The suspended system is designed for installation without a service or drilling rig. Maximum run depths approach 3500 meters.

Piezo

Press.

Range 150psi – 20kpsi @ 150⁰C [1.03—137.9 MPa] Accuracy ± 0.050% full scale

Temp.

Max. Temp 150⁰C Accuracy ± 1.0°C

Quartz Sensor Press.

Range 5kpsi – 25kpsi @ 225⁰C [34.5—172.4 MPa] Accuracy ± 0.015% full scale Temp.

Max. Temp. 225⁰C Accuracy ± 0.15⁰C

Piezometer

Press.

Range 150psi – 3600psi @ 250⁰C [1.03—24.8 MPa] Accuracy ± 10% of the measured value

Temp.

Max. Temp. 250⁰C Accuracy ±0.1% full scale

Thermocouples Max. Temp. 800⁰C Accuracy ± 2⁰C RTD Max. Pressure 20 kpsi [137.9 MPa] Operating Range -40⁰C to 260⁰C Accuracy ± 0.05⁰C