Download - Periprosthetic fractures around the knee
![Page 1: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/1.jpg)
![Page 2: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/2.jpg)
TKA periprosthetic fractures
![Page 3: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/3.jpg)
Incidence
Risk Factors
Patient Evaluation
Classifications
Treatment
Complications
![Page 4: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/4.jpg)
0.3% to 2.5%
> 60 yrs old with osteoporotic bones
0.3% – 0.5%
0.6 %
Overall rate center around 1 %.Higher following revision arthroplasty as opposed to primary implantations.
Incidence
![Page 5: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/5.jpg)
Risk factors
Rheumatoid arthritis
Neurologic disorders
Chronic steroid therapy
Osteopenia/osteoporosis
In Supracondylar #:
-Anterior femoral notching weakens the anterior femur at the bone-component interface
In Tibia #: -Varus positioning and malrotation of the tibial component
In Patella # : -Axial extremity deformities or malalignment of the prosthesis,
-Extensive resections of the patella with thickness <15 mm
** BURNETT, R.S., BOURNE, R.B.: Periprosthetic fractures of the tibia and patella in total knee arthroplasty. Instr. Course Lect, 53: 217-235, 2004.
![Page 6: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/6.jpg)
Patient evaluation
The history and physical examination:
should focus on prefracture knee symptoms such as pain, instability, and stiffness
Infection Workup :
In patients with a loose implant or history of prefracture knee
pain.
Medical Optimization
High-quality Radiographs:
stability & periarticular bone stock.
Status of the soft tissues
The neurovascular status
![Page 7: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/7.jpg)
![Page 8: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/8.jpg)
Definition ??
• Neer 3 inches• Culp 9 cm• Sisto15 cm• In Stemmed
component 5 cm from the proximal end of the implant
Sisto DJ, Lachiewicz PF, Insall JN: Treatment of supracondylar fractures following prosthetic arthroplasty of the knee.ClinOrthop1985;196:265-272.
![Page 9: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/9.jpg)
RORABECK, C.H., TAYLOR, J.W.: Classification of periprosthetic fractures complicating total knee arthroplasty. Orthop. Clin. North Am., 30: 209-214, 1999
Classifications of supracondylar femur periprosthetic fractures
![Page 10: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/10.jpg)
SU, E.T., DEWAL, H., DI CÉSARE, P.E.: Periprosthetic femoral fractures above total knee replacements. J. Am. Acad. Orthop. Surg., 12: 12-20, 2004.
![Page 11: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/11.jpg)
Treament GOALS
stable joint
completed fracture healing (within 6 months)
"range of motion" and restored knee function to the level prior to the trauma.
A functionally favourable result:-- minimum range of motion of 90°
- shortening < 1 cm
- varus-/valgus-misalignment < 5°,
- minimal change in torsion and ante-/retroflexion < 10°
SU, E.T., DEWAL, H., DI CÉSARE, P.E.: Periprosthetic femoral fractures above total knee replacements. J. Am. Acad. Orthop. Surg., 12: 12-20, 2004.
![Page 12: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/12.jpg)
MITTLMEIER, T., STOCKLE, U., PERKA, C., SCHASER, K.D.: Periprosthetic fractures after total knee joint arthroplasty. Unfallchirurg, 108: 481-495; quiz 496, 2005.
![Page 13: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/13.jpg)
Open reduction and internal fixation
a) Dynamic Condylar Screw & Fixed Plade :-
-DIFFICULT to OBTAIN STABLE DISTAL FIXATION
-Limited ability to place blade more distally
-Difficult to change alignment
-Possibility of fragmenting periprosthetic bone
b) Condylar buttress plate:-
-no coronal stability
-varus collapse
![Page 14: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/14.jpg)
a) Retrograde intramedullary nailing:-
Indications:
-open boxes implants
-sufficient distal bone to allow purchase
with minimum 2 distal locking screws
Advantages
-More stable in medial comminution
than locked plates
-soft tissue–friendly
-minimally invasive
Disadvantages:
-Can not use in typically comminuted,
osteopenic distal bony fragments
![Page 15: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/15.jpg)
Indications-sufficiently long distal fragment is present
The main challenge -obtaining accepted alignment and stable distal fixation.
Disadvantages-an area of high-stress concentration is created between the
distal end of the nail and the femoral component.
b) Antegrade femoral nailing
![Page 16: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/16.jpg)
Percutaneous Technique of Distal End of the Femur Using Locked Plating Designs
ADVANTAGES:– Minimal dissection– Preserves blood supply– Rigid internal fixation– Use with/without cables– Unicortical screws– Multiple distal fixation screws
DISADVANTAGES– Can’t contour of titanium plates– More expensive than dynamic plate– Requires special training
CHALLENGE:- Avoid hyperextension & valgus deformity
![Page 17: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/17.jpg)
![Page 18: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/18.jpg)
![Page 19: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/19.jpg)
Role Of Revision Arthroplasty
Indications:
loose prosthesis
inadequate bone stock
nonunion supracondylar fractures that requires
tumor prosthesis.
Requirements:-
Surgeons who have the experience
and technical support
![Page 20: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/20.jpg)
![Page 21: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/21.jpg)
Tibia periprosthetic fractures
FELIX, N.A., STUART, M.J., HANSSEN, A.D.: Periprosthetic fractures of the tibia associated with total knee arthroplasty. Clin. Orthop. Relat. Res., 345: 113-124, 1997.
Felix classification
![Page 22: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/22.jpg)
Treatment
Indications:
Intraoperatively stable undisplaced fractures which are and first seen at the postoperative radiograph
Undisplaced fractures type II.
How ??
an adaptation of the postoperative weight bearing and radiographic controls
BURNETT, R.S., BOURNE, R.B.: Periprosthetic fractures of the tibia and patella in total knee arthroplasty. Instr. Course Lect, 53: 217-235, 2004
FELIX, N.A., STUART, M.J., HANSSEN, A.D.: Periprosthetic fractures of the tibia associated with total knee arthroplasty. Clin. Orthop. Relat. Res., 345: 113-124, 1997.
![Page 23: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/23.jpg)
• OSTEOSYNTHESIS +/- REVISION STEM SYSTEMS
Intraoperative # Subtype C
(type I - III)
• Revision arthroplasty
Loose tibial implant (subtype B)
ALL TYPES
• Loss of extension function is an indication for : osteosyntheticreconstruction,+/-revision arthroplasty
Type IV fractures
![Page 24: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/24.jpg)
![Page 25: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/25.jpg)
Periprosthetic Patellar Fractures
![Page 26: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/26.jpg)
PERIPROSTHETIC PATELLAR FRACTURES
Goldberg Classification
GOLDBERG, V.M., FIGGIE, H.E., 3rd, INGLIS, A.E., FIGGIE, M.P., SOBEL, M., KELLY, M., KRAAY, M.: Patellar fracture type and prognosis in condylar total knee arthroplasty. Clin. Orthop. Relat. Res., 236: 115-122, 1988
![Page 27: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/27.jpg)
• If Intact extensor mechansimConservativeTYPE I
• Stable implantstension band/screw
• loose implantsTension band/screw + revision TYPE II
• Type III A fractures with fixed implant are treated according to guidelines for the management of patellar tendon ruptures
• Type III B : stable conservative loose revision
Type III
CHALIDIS, B.E.,TSIRIDIS, E., TRAGAS, A.A., STAVROU, Z., GIANNOUDIS, P. V.: Management of periprosthetic patellar fractures - A systematic review of literature. Injury, 38: 714-724, 2007.CROSSETT, L.S., SINHA, R.K., SECHRIEST, V.E., RUBASH, H.E.: Reconstruction of a ruptured patellar tendon with achillestendon allograft following total knee arthroplasty. J. Bone Jt Surg., 84-A: 1354-1361, 2002.
TREATMENT
![Page 28: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/28.jpg)
in a systematic study analyzing complications of 415 periprosthetic femur fractures Herrera et al. observed:-
9% pseudarthroses/non-unions4% mechanical complications 3% infections with an overall revision rate, reaching 13%.
complications
HERRERA, D.A., KREGOR, P.J., COLE, P.A., LEVY, B.A., JONSSON, A., ZLOWODZKI, M.: Treatment of acute distal femur fractures above a total knee arthroplasty: systematic review of 415 cases (1981-2006). Acta Orthop., 79: 22-27, 2008.
![Page 29: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/29.jpg)
Take home message
![Page 30: Periprosthetic fractures around the knee](https://reader033.vdocuments.us/reader033/viewer/2022052700/55a1f7dd1a28ab596d8b4604/html5/thumbnails/30.jpg)