Preface
i
Preface
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
6/541
Preface
ii
Before reading the command reference
This device has two types of modes to use commands.
General mode: Mode to use terminal local set commands that do not involve display systemand configuration update (default)
Privileged mode: Mode to use all commands related to usual maintenance operation such asdisplay commands and configuration commands
Marks located at the top of descriptions for each command indicate following meanings:
Privilege Indicates that this command can be used in privileged mode.*
General Indicates that this command can be used in general mode.** When both are displayed, the command can be used in both modes.
Save Indicates that the settings can be saved.(Without an indication, the settings for the command cannot be saved.)
Notation in "Input format" includes following meanings.
Parameters enclosed in brackets can be omitted.
When multiple parameters are enclosed in a pair of brackets, all the parameters enclosedcan be omitted.
Example)
[P1] : P1 can be omitted.
[P1 P2] : P1 and P2 can be omitted. Either one of P1 or P2 cannot be omitted.
[P1[P2]] : P1 and P2 can be omitted. P2 can be omitted without omitting P1,but P1 cannot be omitted without omitting P2.
Commands described with multiple input formats vary parameters to be specified accordingto the settings.
In such a case, the key parameter is indicated as "Px (bold italic)" with an explanation.
Example)
P1 (aaa/bbb) P2 P3 : When aaa or bbb is specified in P1, specify P2 and P3.
P1 (ccc) P4 P5 : When ccc is specified in P1, specify P4 and P5.
GeneralMode
PrivilegedMode
enable
disable
Mode Transition and Command for Transition
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
7/541
Preface
iii
Notation in "Parameters" includes following meanings.
Braces indicate that one of the keywords delimited by | vertical bars must be selected.
indicates that subsequent parameter to be specified varies according to parameterspreviously specified.
In such a case, the affected parameter is indicated as "indent | (vertical bar)". All theparameters are affected as long as "indent |" continues.
* indicates a supplement for the parameter.
In command input, use ASCII characters (excluding control characters).
Usable characters:
[space] !"#$%&'()*+,-./0123456789:;?@ABCDEFGHIJKLMN
OPQRSTUVWXYZ [\]^_`abcdefghijklmnopqrstuvwxyz{|}~
Also, the following characters can be used as VLAN and PVC names.
Usable characters: (The first character must be an alphabetic character.)Alphanumeric characters, "-", and "_"
Finer restrictions are applied to some commands.
(For details, see the Note field of each command.)
Cautions
(1) No part of this manual may be reproduced without prior written permission of the publisher.
(2) The contents of this manual may be revised without prior notice.
(3) All efforts have been made to ensure the accuracy of all information in this manual.If you notice any part unclear, incorrect, or omitted in this manual, contact NEC.
(4) NEC assumes no liability for the result of operations despite (3).
(5) If you find any missing pages or pages out of order in this manual, please contact NEC for areplacement.
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
8/541
Preface
iv
(Blank page)
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
9/541
Preface
v
Contents
Preface..............................................................................................i
Before reading the command reference............................................................... ii
1 Operation Modes ..................................................................... 1-1
Logout.................................................................................................................... 1-2
Switch from general mode to privileged mode ....................................................... 1-3
Switch from privileged mode to general mode....................................................... 1-4
Setting of privileged mode password ..................................................................... 1-5Clearing of privileged mode password ................................................................... 1-6
Setting of login password....................................................................................... 1-7
Clearing of login password..................................................................................... 1-8
Setting of terminal prompt...................................................................................... 1-9
Setting of scroll control defaults ............................................................................ 1-10
Setting of local terminal scroll control.................................................................... 1-11
Setting of autonomous message output................................................................ 1-12
Setting of automatic logout time............................................................................ 1-13
Display of terminal information.............................................................................. 1-14
Registration of user account ................................................................................. 1-15
Display of user account......................................................................................... 1-16
Clearing of user account ....................................................................................... 1-17
2 Global Configuration............................................................... 2-1
Setting of administrator contact.............................................................................. 2-2
Setting of system name ......................................................................................... 2-3
Setting of system location ...................................................................................... 2-4
Display of system information ................................................................................ 2-5
Setting of date and time ......................................................................................... 2-6
Setting of timezone ................................................................................................ 2-7
Setting of daylight saving time ............................................................................... 2-8
Display of date and time ....................................................................................... 2-11
Clearing of daylight saving time ............................................................................ 2-12
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
10/541
Preface
vi
3 Administration Ports ............................................................... 3-1
Setting of outband IP address................................................................................ 3-2
Clearing of outband IP address.............................................................................. 3-3
Setting of in-band IP address................................................................................. 3-4Display of in-band port setup information............................................................... 3-5
Clearing of in-band IP address............................................................................... 3-6
Setting of default gateway...................................................................................... 3-7
Clearing of default gateway.................................................................................... 3-8
Setting of static route ............................................................................................. 3-9
Display of network information.............................................................................. 3-10
Clearing of static route.......................................................................................... 3-12
Setting of outband port speed/communication direction ....................................... 3-13
Setting of outband port flow control....................................................................... 3-14
Display of outband port setup information............................................................. 3-15
Block/unblock of in-band port................................................................................ 3-17
Setting of in-band port VLAN ................................................................................ 3-18
Clearing of in-band port VLAN.............................................................................. 3-19
Checking of connection......................................................................................... 3-20
4 Ports.......................................................................................... 4-1
Setting of port blocking/unblocking ........................................................................ 4-2
Setting of port speed and MDI/MDI-X .................................................................... 4-3
Setting of GbE port media...................................................................................... 4-5
Setting of flow control............................................................................................. 4-6
Setting of port link protection time.......................................................................... 4-7
Setting of SNMP link trap transmission.................................................................. 4-8
Setting of port frame .............................................................................................. 4-9
Setting of port mode.............................................................................................. 4-11
Setting of ATM transmission path clock ................................................................ 4-13
Display of port setting and status information ....................................................... 4-14
Setting of port cable length ................................................................................... 4-20
Display of port cable length settings ..................................................................... 4-21
Setting of impedance ............................................................................................ 4-23
Display of impedance setting ................................................................................ 4-24
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
11/541
Preface
vii
5 VLAN......................................................................................... 5-1
Setting of tagbase VLAN........................................................................................ 5-2
Clearing of tagbase VLAN...................................................................................... 5-3
Setting of portbase VLAN....................................................................................... 5-4Display of VLAN table per port............................................................................... 5-5
Display of VLAN table per VLAN............................................................................ 5-6
Setting of portbase VLAN and tagbase VLAN en bloc ........................................... 5-7
Setting of VLAN tag swapping ............................................................................... 5-8
Display of VLAN tag swapping information ............................................................ 5-9
Clearing of VLAN tag swapping ............................................................................ 5-10
Display of number of VLAN entries ....................................................................... 5-11
Setting of Ethernet type for VLAN tag recognition................................................. 5-13
Display of Ethernet type information for VLAN tag recognition .............................5-14
Setting of VLAN name .......................................................................................... 5-15
Clearing of VLAN name ........................................................................................ 5-16
6 QoS ........................................................................................... 6-1
Setting of maximum bandwidth limit function per input VLAN................................ 6-2
Setting of priority mapping function per input VLAN............................................... 6-4
Setting of priority discard function per input VLAN................................................. 6-7
Display of maximum bandwidth limit function per input VLAN ..............................6-11
Clearing of maximum bandwidth limit function per input VLAN.............................6-14
Setting of input CoS priority mapping.................................................................... 6-16
Display of input CoS priority mapping ................................................................... 6-17
Setting of input CoS priority mapping enable/disable............................................ 6-18
Display of input CoS priority mapping enable/disable ........................................... 6-19
Setting of L2 switch buffer..................................................................................... 6-20
Display of L2 switch buffer .................................................................................... 6-22
Setting of class mapping for switch fabric ............................................................. 6-24
Display of class mapping setting of switch fabric .................................................. 6-26
Setting of output bandwidth................................................................................... 6-27
Display of output bandwidth.................................................................................. 6-31
Setting the output WRED function ........................................................................ 6-34
Display of the output WRED function.................................................................... 6-36
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
12/541
Preface
viii
7 Switch Control ......................................................................... 7-1
Setting of frame size .............................................................................................. 7-2
Display of frame size.............................................................................................. 7-3
Setting of aging time .............................................................................................. 7-4Display of aging time.............................................................................................. 7-5
Display of MAC learning count per port ................................................................. 7-6
Display of MAC learning count per VLAN .............................................................. 7-8
Display of MAC learning count per device ............................................................. 7-9
Display of MAC learning information per port........................................................ 7-10
Clearing of MAC learning information per port...................................................... 7-12
Display of MAC learning information per VLAN .................................................... 7-13
Clearing of MAC learning information per VLAN................................................... 7-15
8 Route Control........................................................................... 8-1
Setting of spanning tree protocol enable/disable support ...................................... 8-2
Setting of spanning tree mode ............................................................................... 8-3
Display of spanning tree mode............................................................................... 8-4
Setting of switch priority ......................................................................................... 8-5
Setting of spanning tree timer ................................................................................ 8-6
Setting of hold count .............................................................................................. 8-7
Display of spanning tree switch information........................................................... 8-8
Setting of spanning tree enable/disable per port................................................... 8-10
Setting of priority per port...................................................................................... 8-11
Setting of path cost per port.................................................................................. 8-12
Display of spanning tree port information.............................................................. 8-13
Setting of edge port............................................................................................... 8-15
Display of edge port .............................................................................................. 8-16
Setting of point-to-point......................................................................................... 8-17
Display of point-to-point ........................................................................................ 8-18
Setting of link aggregation group .......................................................................... 8-19
Display of link aggregation setting status.............................................................. 8-21
Clearing of link aggregation group ........................................................................ 8-23
Setting of system priority....................................................................................... 8-24
Display of system priority ...................................................................................... 8-25
Setting of port priority............................................................................................ 8-26
Display of port priority ........................................................................................... 8-27
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
13/541
Preface
ix
Setting of link aggregation protection time ............................................................ 8-28
Display of link aggregation protection time............................................................ 8-29
9 Filters........................................................................................ 9-1
Setting/clearing of port isolate................................................................................ 9-2
Display of port isolate setting state ........................................................................ 9-4
Setting of input filtering .......................................................................................... 9-6
Display of input filtering.......................................................................................... 9-8
Clearing of input filtering ........................................................................................ 9-9
10 EtherOAM ............................................................................. 10-1
Setting of MEG...................................................................................................... 10-2Display of MEG setting information....................................................................... 10-3
Clearing of MEG ................................................................................................... 10-5
Setting of MEP...................................................................................................... 10-6
Display of MEP setting information ....................................................................... 10-8
Clearing of MEP.................................................................................................. 10-12
Setting of test target MEP ................................................................................... 10-13
Display of test target MEP................................................................................... 10-14
Clearing of test target MEP................................................................................. 10-15
Setting of associated MEP ID ............................................................................. 10-16
Clearing of associated MEP ID ........................................................................... 10-17
Setting of EtherOAM frame common information................................................ 10-18
Display of EtherOAM frame common information............................................... 10-19
Setting of Reply frame returning period .............................................................. 10-20
Display of Reply frame returning period.............................................................. 10-21
Display of EtherOAM MAC address.................................................................... 10-22
Setting of EtherOAM Continuity Check transmission .......................................... 10-23
Setting of RDI operation...................................................................................... 10-24
Display of final fault information .......................................................................... 10-25
Display of CCM error cause................................................................................ 10-26
Clearing of CCM error cause .............................................................................. 10-28
Executing of ETH-LB .......................................................................................... 10-29
Executing of ETH-LT........................................................................................... 10-31
Executing of ETH-DM ......................................................................................... 10-33
Executing of ETH-LM.......................................................................................... 10-35
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
14/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
15/541
Preface
xi
Setting of Egress CLP conversion priority........................................................... 12-10
Display of Egress CLP conversion setting status................................................ 12-11
Setting of CLP-PW Priority mapping ................................................................... 12-13
Display of CLP-PW Priority mapping setting status ............................................ 12-15
13 ATM-OAM ............................................................................. 13-1
Setting of ATM-OAM operation ............................................................................. 13-2
Setting of ATM-OAM flow point............................................................................. 13-4
Display of ATM-OAM setting information .............................................................. 13-6
Display of ATM-OAM status information ............................................................... 13-9
14 ATM-IMA ............................................................................... 14-1
Setting of IMA group ............................................................................................. 14-2
Display of IMA group setting information .............................................................. 14-4
Display of IMA group status information ............................................................... 14-5
Clearing of IMA group........................................................................................... 14-8
Setting of IMA clock mode .................................................................................... 14-9
Display of IMA clock mode setting information.................................................... 14-10
15 TDM-Path.............................................................................. 15-1
Setting of TDM group............................................................................................ 15-2
Display of TDM group setting information ............................................................. 15-3
Clearing of TDM group.......................................................................................... 15-4
Setting of TDM path.............................................................................................. 15-5
Display of TDM path setting information ............................................................... 15-6
Clearing of TDM path............................................................................................ 15-7
16 TDM over Packet.................................................................. 16-1
Setting of TDMoP mode........................................................................................ 16-2
Setting of TDMoP group........................................................................................ 16-4
Display of TDMoP group setting information......................................................... 16-6
Clearing of TDMoP group ..................................................................................... 16-8
Setting of TDMoP connection ............................................................................... 16-9
Display of TDMoP connection setting ................................................................. 16-11
Clearing of TDMoP connection ........................................................................... 16-14Setting of variation tolerance............................................................................... 16-15
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
16/541
Preface
xii
Display of variation tolerance.............................................................................. 16-17
Display of TDMoP path setting status information .............................................. 16-18
Setting of TDMoP format..................................................................................... 16-19
Display of TDMoP format setting ........................................................................ 16-21
Clearing of TDMoP format .................................................................................. 16-24
Setting of TDMoP blocking.................................................................................. 16-25
Resetting of CESoP device................................................................................. 16-26
Display of CESoP device status.......................................................................... 16-27
17 Clock Control ....................................................................... 17-1
Setting of port (line)-independent clock mode....................................................... 17-2
Setting of reference clock priority.......................................................................... 17-3
Setting of reference clock switchover mode.......................................................... 17-5
Resetting of reference clock.................................................................................. 17-6
Setting of reference clock group ........................................................................... 17-7
Display of reference clock information .................................................................. 17-9
Setting of adaptive clock ..................................................................................... 17-12
Display of adaptive clock setting......................................................................... 17-14
Clearing of adaptive clock................................................................................... 17-19
Setting of adaptive clock mode ........................................................................... 17-21Setting of adaptive clock format.......................................................................... 17-23
Clearing of adaptive clock format setting ............................................................ 17-25
18 Network Management ......................................................... 18-1
Setting of SNMP enable/disable ........................................................................... 18-2
Setting of SNMP manager .................................................................................... 18-3
Setting of SNMP trap manager ............................................................................. 18-4
Clearing of SNMP manager settings..................................................................... 18-5
Clearing of SNMP trap manager settings.............................................................. 18-6
Setting of SNMP unauthorized access trap transmission ..................................... 18-7
Display of SNMP setting information..................................................................... 18-8
Setting of access list ........................................................................................... 18-11
Display of access list........................................................................................... 18-12
Clearing of access list ......................................................................................... 18-13
Display of session............................................................................................... 18-14
Clearing of session ............................................................................................. 18-15
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
17/541
Preface
xiii
Setting of remote log enable/disable................................................................... 18-16
Setting of syslog server and message facility ..................................................... 18-17
Display of syslog server configuration information .............................................. 18-18
Clearing of syslog server..................................................................................... 18-19
Setting of syslog message level remapping........................................................ 18-20
Display of syslog message level mapping status................................................ 18-21
Clearing of syslog message level remapping...................................................... 18-22
Display of local log.............................................................................................. 18-23
Clearing of local log ............................................................................................ 18-25
Setting of NTP access time................................................................................. 18-26
Setting of IP address of NTP server.................................................................... 18-27
Display of NTP server setting information........................................................... 18-28
Clearing of IP address of NTP server ................................................................. 18-29
19 Network Test ........................................................................ 19-1
Starting of ATM loopback test............................................................................... 19-2
Setting of ATM loopback source ID....................................................................... 19-6
Display of ATM loopback source ID...................................................................... 19-7
Setting of ATM loopback monitoring mode ........................................................... 19-8
Display of ATM loopback monitoring configuration ............................................... 19-9Setting of ATM loopback monitoring function...................................................... 19-12
Display of ATM loopback monitoring information ................................................ 19-14
Clearing of ATM loopback monitoring function.................................................... 19-16
20 Monitors................................................................................ 20-1
Display of port counter .......................................................................................... 20-2
Clearing of port counter ........................................................................................ 20-5
Display of discard counter..................................................................................... 20-6
Registration of VLAN counter................................................................................ 20-9
Display of VLAN counter registration information................................................ 20-10
Clearing of VLAN counter registration................................................................. 20-11
Display of VLAN counter..................................................................................... 20-12
Clearing of VLAN counter ................................................................................... 20-16
Registration of PVC for OAM counter .................................................................20-17
Display of PVC for OAM counter......................................................................... 20-18
Clearing of PVC for OAM counter ....................................................................... 20-19
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
18/541
Preface
xiv
Display of cell counter information ...................................................................... 20-20
Display of cell counter information per F4........................................................... 20-23
Display of cell counter information per F5........................................................... 20-26
Display of cell counter information per IMA group port ....................................... 20-29
Clearing of cell counter information..................................................................... 20-31
Display of port (line) quality counter.................................................................... 20-32
Registration of EtherOAM counter ...................................................................... 20-34
Display of EtherOAM counter registration information ........................................ 20-35
Clearing of EtherOAM counter registration ......................................................... 20-37
Display of EtherOAM counter.............................................................................. 20-38
Setting of mirroring start or stop.......................................................................... 20-39
Display of mirroring settings................................................................................ 20-40
21 Maintenance and Operation ............................................... 21-1
Uploading of running configuration to FTP server................................................. 21-2
Uploading of startup configuration to FTP server.................................................. 21-3
Uploading of system log to FTP server................................................................. 21-4
Uploading of setting information to FTP server..................................................... 21-5
Uploading of fault information to FTP server......................................................... 21-6
Downloading of FPGA .......................................................................................... 21-7Downloading of software....................................................................................... 21-9
Downloading of running configuration from FTP server ...................................... 21-10
Downloading of startup configuration from FTP server ....................................... 21-11
Display of running configuration.......................................................................... 21-12
Display of startup configuration........................................................................... 21-14
Setting of trap transmission selection ................................................................. 21-16
Display of trap transmission selection setting status........................................... 21-19
Display of all setting information ......................................................................... 21-22
Saving of setting information............................................................................... 21-24
Clearing of startup configuration ......................................................................... 21-25
Display of current fault and alarm information..................................................... 21-26
Clearing of WR fault............................................................................................ 21-28
Display of past fault information .......................................................................... 21-29
Clearing of past fault information ........................................................................ 21-32
Display of device installation status and other various statuses..........................21-33
Display of bridge information for device .............................................................. 21-35
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
19/541
Preface
xv
Display of module ID information ........................................................................ 21-36
Display of various version information ................................................................ 21-38
Display of device temperature............................................................................. 21-40
Setting of autonomous rebooting enable/disable ................................................ 21-41
Display of autonomous rebooting settings .......................................................... 21-42
Display of CPU usage......................................................................................... 21-43
Display of memory usage.................................................................................... 21-44
22 Device Control ..................................................................... 22-1
Resetting of entire device...................................................................................... 22-2
Display of reset factor ........................................................................................... 22-4
23 Appendix .............................................................................. 23-1
Appendix 1 Commands shown by configuration display and show all.......23-2Appendix 2 Port (line) interface type conditions ........................................... 23-9
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
20/541
(blank page)
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
21/541
Operation Modes
1-1
1 Operation Modes
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
22/541
Operation Modes
1-2
General Privilege Save
exit
Logout
This command is used for logout from CLI.
Input format None
Parameter None
Default value None
Usage condition None
Note None
Input example *Switch# exit
Output item
Relatedcommands
enable Switch from general mode to privileged mode
disable Switch from privileged mode to general mode
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
23/541
Operation Modes
1-3
General Privilege Save
enable
Switch from general mode to privileged mode
Enables you to switch from general mode to privileged mode.
Input format None
Parameter None
Default value None
Usage condition Interactively enter your privileged mode password. When not setting this password,press [Enter].
Note None
Input example *Switch> enableInput enable password:
*Switch#
Output item
Relatedcommands
exit Logout
disable Switch from privileged mode to general mode
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
24/541
Operation Modes
1-4
General Privilege Save
disable
Switch from privileged mode to general mode
Enables you to switch from privileged mode to general mode.
Input format None
Parameter None
Default value None
Usage condition None
Note None
Input example *Switch# disable*Switch>
Output item
Relatedcommands
exit Logout
enable Switch from general mode to privileged mode
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
25/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
26/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
27/541
Operation Modes
1-7
General Privilege Save
set login password
Setting of login password
Sets your login password.
Input format None
Parameter None
Default value None
Usage condition Set your login password interactively.
Note Set this password with 4 to 16 ASCII characters other than [space], [!], [?], and [controlcharacter].
Input example *Switch# set login passwordInput old password:
Input new password:
Retype new password:
*Switch#
Output item
Relatedcommands
exit Logout
clear login password Clearing of login password
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
28/541
Operation Modes
1-8
General Privilege Save
clear login password
Clearing of login password
Clears your login password.
Input format None
Parameter None
Default value None
Usage condition Clear your login password interactively.
Note Set this password with 4 to 16 ASCII characters other than [space], [!], [?], and [controlcharacter].
Input example *Switch# clear login passwordInput old password:
*Switch#
Output item
Relatedcommands
exit Logout
set login password Setting of login password
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
29/541
Operation Modes
1-9
General Privilege Save
set terminal prompt
Setting of terminal prompt
Sets a terminal prompt.
Input format P1
Parameter P1: Terminal prompt name (1 to 20 characters)
Default value P1: Switch
Usage condition None
Notes Terminal prompts for other than the set terminal are set at reconnection.
Set this prompt name with ASCII characters other than ["], [?], and [control character].
When using [space], enclose the entire character string in double quotation marks.
Input example *Switch# set terminal prompt CX2200*CX2200#
Output item
Relatedcommand
None
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
30/541
Operation Modes
1-10
General Privilege Save
set terminal scroll system
Setting of scroll control defaults
Sets scroll control defaults.
Input formats - Specifying that screen scroll stop is off
P1 (off)
- Specifying that screen scroll stop is on
[P1 (on) ] [P2]
Parameters P1: Scroll control { off | on }
off: Screen scroll stop is off
on: Screen scroll stop is on
* When P1 is omitted, on is assumed.
When on is specified in P1.
P2: Number of scroll lines (1 to 99)
* When P2 is omitted, 22 is assumed.
Default values P1: on
P2: 22
Usage condition None
Note Scroll control defaults are set in all terminals at reconnection.
Input example *Switch# set terminal scroll system on*Switch#
Output item
Relatedcommand
show terminal config Display of terminal information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
31/541
Operation Modes
1-11
General Privilege Save
set terminal scroll local
Setting of local terminal scroll control
Sets local terminal scroll control.
Input formats - Specifying that screen scroll stop is off
P1 (off)
- Specifying that screen scroll stop is on
[P1 (on) ] [P2]
Parameters P1: Scroll control { off | on }
off: Screen scroll stop is off
on: Screen scroll stop is on
* When P1 is omitted, on is assumed.
When on is specified in P1.
P2: Number of scroll lines (1 to 99)
* When P2 is omitted, 22 is assumed.
Default value P1: on
P2: 22
Usage condition None
Notes Local terminal scroll control only for the set terminal is set.
A local terminal operates in scroll control default setting at reconnection.
Input example *Switch# set terminal scroll local on*Switch#
Output item
Relatedcommand show terminal config Display of terminal information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
32/541
Operation Modes
1-12
General Privilege Save
set terminal monitor
Setting of autonomous message output
Sets autonomous message output.
Input format P1
Parameter P1: Autonomous message control { enable | disable }
enable: Enables autonomous message output
disable: Disables autonomous message output
Default values P1: [RS-232C] enable
[telnet] disable
Usage condition None
Notes Autonomous message output is suppressed during command execution.
Terminals operate by default at reconnection.
Input example *Switch# set terminal monitor enable*Switch#
Output item
Relatedcommand
show terminal config Display of Show terminal information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
33/541
Operation Modes
1-13
General Privilege Save
set terminal logout
Setting of automatic logout time
Sets automatic logout time.
Input format P1
Parameter P1: Automatic logout time (0 to 60 minutes)
0: Disables automatic logout time setting
Default value P1: 5 minutes
Usage condition None
Note Automatic logout time for other than the set terminal is set at reconnection.
Input example *Switch# set terminal logout 60*Switch#
Output item
Relatedcommand
show terminal config Display of terminal information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
34/541
Operation Modes
1-14
General Privilege Save
show terminal config
Display of terminal information
Shows terminal information.
Input format None
Parameter None
Default value None
Usage condition None
Note None
Input example *Switch# show terminal configCurrent Terminal Configuration
==============================
Console TimeOut (minutes) : 60
Output Length : off
Alarm Monitor : disabled
Default Terminal Configuration
==============================
Console TimeOut (minutes) : 60
Output Length : 99
*Switch#
Output items Console TimeOut (minutes): Automatic logout time (minutes)
Output Length: Scroll control
off: Screen scroll stop is off
XX: Scroll line
Alarm Monitor: Autonomous message output controlenable: Enables autonomous message output
disable: Disables autonomous message output
Relatedcommands
set terminal scroll system Setting of scroll control defaults
set terminal scroll local Setting of local terminal scroll control
set terminal monitor Setting of autonomous message output
set terminal logout Setting of automatic logout time
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
35/541
Operation Modes
1-15
General Privilege Save
set user account
Registration of user account
Registers a user account or changes the password of the registered user account.
Input format P1 P2
Parameters P1: User account name (1 to 10 characters)
P2: Permission specification { read-only | read-write }
read-only: General mode
read-write: Privileged mode
Default value None
Usage condition Set your password interactively.
Notes Set a user account with ASCII characters other than ["], [?], and [control character].
When using [space], enclose the entire character string in double quotation marks.
You can register up to six user accounts except the default user account.
You can change the password of the registered user account by specifying the sameuser account name and user privilege as the registered user account and entering theold password.
Set the password with 4 to 16 ASCII characters other than [space], [!], [?], and [controlcharacter].
Input example *Switch# set user account cx2200 read-writeInput password:
Retype password:
*Switch#
Output item
Relatedcommands
show user account Display of user account
clear user account Clearing of user account
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
36/541
Operation Modes
1-16
General Privilege Save
show user account
Display of user account
Shows registered user account information.
Input format None
Parameter None
Default value None
Usage condition None
Note None
Input example *Switch# show user accountUser Information
================
User Name Rights
--------------------------------
admin read-write
ippan read-only
tokken read-write
cx2200 read-write
*Switch#
Output items User Name: User account name
Rights: Mode rights
read-only: General mode
read-write: Privileged mode
Relatedcommands
set user account Registration of user account
clear user account Clearing of user account
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
37/541
Operation Modes
1-17
General Privilege Save
clear user account
Clearing of user account
Clears a user account.
Input format P1
Parameter P1: User account name (1 to 10 characters)
Default value None
Usage condition None
Notes You cannot clear the default user account "admin".
Set a user account with 4 to 16 ASCII characters other than ["], [?], and [controlcharacter].
When using [space], enclose the entire character string in double quotation marks.
Input example *Switch# clear user account cx2200*Switch#
Output item
Relatedcommands
set user account Registration of user account
show user account Display of user account
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
38/541
(blank page)
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
39/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
40/541
Global Configuration
2-2
General Privilege Save
set system contact
Setting of administrator contact
Sets an administrator to contact.
Input format P1
Parameter P1: Administrator to contact (0 to 255 characters)
Default value None
Usage condition None
Notes To return the set administrator contact to the default value, set " " in P1.
Set an administrator contact with ASCII characters (excluding control characters) likenormal command entry.
Input example *Switch# set system contact abc*Switch#
Output item
Relatedcommand
show system information Display of system information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
41/541
Global Configuration
2-3
General Privilege Save
set system name
Setting of system name
Sets system name.
Input format P1
Parameter P1: System name (0 to 255 characters)
Default value None
Usage condition None
Notes To return the set system name to the default value, set " " in P1.
Set a system name with ASCII characters (excluding control characters) like normalcommand entry.
Input example *Switch# set system name CX2200*Switch#
Output item
Relatedcommand
show system information Display of system information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
42/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
43/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
44/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
45/541
Global Configuration
2-7
General Privilege Save
set system timezone
Setting of timezone
Sets timezone.
Input format P1
Parameter P1: Timezone (hh:mm)
: Sign - or +
hh: Hour (00-23)
mm: Minute (00-59)
Default value P1: +9:00
Usage condition Always specify a sign of time difference.
Note None
Input example *Switch# set system timezone +09:00*Switch#
Output item
Relatedcommands
date Setting of date and time
show system date Display of date and time
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
46/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
47/541
Global Configuration
2-9
When daylight saving time specification by week is specified in P1.
P5: a start day of the week { sunday | monday | tuesday | wednesday |thursday | friday | Saturday }
sunday: Sunday
monday: Monday
tuesday: Tuesdaywednesday: Wednesday
thursday: Thursday
friday: Friday
saturday: Saturday
P6: Start month (1-12)
P7: Start time (hh:mm)
hh: Hour (00-23)
mm: Minute (00-59)
P8: End week { first | second | third | fourth | last }
first: The first week
second: The second weekthird: The third week
fourth: The fourth week
last: The last week
P9: an end day of the week { sunday | monday | tuesday | wednesday |thursday | friday | saturday }
sunday: Sunday
monday: Monday
tuesday: Tuesday
wednesday: Wednesday
thursday: Thursday
friday: Fridaysaturday: Saturday
P10: End month (1-12)
P11: End time (hh:mm)
hh: Hour (00-23)
mm: Minute (00-59)
P12: Time difference by daylight saving time (hh:mm)
hh: Hour (00-23)
mm: Minute (00 to 59)
* When P12 is omitted, 01:00 is assumed.
Default value None
Usage condition In date specification, you cannot specify the same date for start/end date of daylightsaving time. Also, in specification of a day of week, you cannot specify the samemonth/date/day of week for start/end date of daylight saving time.
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
48/541
Global Configuration
2-10
Notes When daylight saving time starts, the clock is not set to the set start time, movingforward corresponding to the time difference by daylight saving time.
Example) When the start time is 1:00 and time difference by daylight saving time is 0:30
0:58 -> 0:59 -> 1:30
When daylight saving time ends, the clock is not set to the set end time, movingbackward corresponding to the time difference by daylight saving time.
Example) When the end time is 2:00 and time difference by daylight saving time is 0:30
1:58 -> 1:59 -> 1:30
If daylight saving time is shorter than time difference by daylight saving time, thespecified end date is changed to that of the next year.
If the start date or the end date is Feb. 29, daylight saving time is applied only to leapyears. If Feb. 29 is set as the start date and the daylight saving time is shorter than
time difference by daylight saving time, the end date is changed to that of the next yearof the leap year. If Feb. 29 is set as the end date and the daylight saving time is shorterthan time difference by daylight saving time, the start date is changed to that of theprevious year of a leap year.
During daylight saving time, (DST) is shown in the current time.
Input example *Switch# set system daylight-time first sunday 4 1:00 last saturday 102:00 0:30
*Switch#
Output item
Relatedcommands
date Setting of date and time
show system date Display of date and time
clear system daylight-time Clearing of daylight saving time
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
49/541
Global Configuration
2-11
General Privilege Save
show system date
Display of date and time
Shows system date and time.
Input format [P1]
Parameter P1: Showing type { detail }
detail: Detailed showing
* When P1 is omitted, setting of daylight saving time is not shown.
Default value None
Usage condition None
Note None
Input example *Switch# show system date detailSystem Date
===========
Current Date : 09/21/2006
Current Time : 14:14:47 (DST)
Time Zone : GMT +09:00Daylight Time Start : 04/02/2006 01:00
Daylight Time End : 10/28/2006 02:00
Daylight Time Offset: 00:30
*Switch#
Output items Current Date: Date
Current Time: Time
Time Zone: Time difference from Greenwich mean time
Daylight Time Start: Start date and time of daylight saving time
Daylight Time End: End date and time of daylight saving time
Daylight Time Offset: Time difference by daylight saving time
Relatedcommands
date Setting of date and time
set system timezone Setting of timezone
set system daylight-time Setting of daylight saving time
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
50/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
51/541
Administration Ports
3-1
3 Administration Ports
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
52/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
53/541
Administration Ports
3-3
General Privilege Save
clear ip address out-band
Clearing of outband IP address
Initializes the IP address of an outband port.
Input format None
Parameter None
Default value None
Usage condition None
Note If you log in via telnet communication, the login session close confirmation message isoutput.
Input example *Switch# clear ip address out-band*Switch#
Output item
Relatedcommands
set ip address out-band Setting of outband IP address
set ip route default Setting of default gateway
set ip route Setting of static route
show ip config Displays of network information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
54/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
55/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
56/541
Administration Ports
3-6
General Privilege Save
clear ip address in-band
Clearing of in-band IP address
Clears logical interface settings.
Input format None
Parameter None
Default value None
Usage condition None
Note None
Input example *Switch# clear ip address in-band*Switch#
Output item
Relatedcommands
set ip address in-band Setting of in-band IP address
show in-band information Display of in-band port setup information
set ip route default Setting of default gateway
set ip route Setting of static route
show ip config Display of network information
set in-band vid Setting of in-band port VLAN
clear in-band vid Clearing of in-band port VLAN
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
57/541
Administration Ports
3-7
General Privilege Save
set ip route default
Setting of default gateway
Sets a default gateway.
Input format P1
Parameter P1: IP address
Default value None
Usageconditions
If a default gateway is set in inband communication, a default gateway cannot be usedin outband communication. If a default gateway is set in inband communication, thedefault gateway that is already set in outband communication is disabled.
If a default gateway is set in outband communication, the default gateway that isalready set in inband communication is disabled.
You cannot set 0.xxx.xxx.xxx/127.xxx.xxx.xxx and 224.xxx.xxx.xxx to 255.xxx.xxx.xxxas the IP address. ("xxx" is any number.)
If you set 0 or 1 to all bits of the host part as the IP address, this setting may notprovide correct communication.
You can set the network addresses 192.168.128.0/24 and 192.168.129.0/24 as thegateway address but this setting does not provide correct communication.
Note If you log in via telnet communication, the login session close confirmation message isoutput.
Input example *Switch# set ip route default 10.20.30.40*Switch#
Output item
Relatedcommands
set ip address out-band Setting of outband IP addressclear ip address out-band Clearing of outband IP address
clear ip route default Clearing of default gateway
show ip config Display of network information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
58/541
Administration Ports
3-8
General Privilege Save
clear ip route default
Clearing of default gateway
Clears a default gateway.
Input format None
Parameter None
Default value None
Usage condition None
Note If you log in via telnet communication, the login session close confirmation message isoutput.
Input example *Switch# clear ip route default*Switch#
Output item
Relatedcommands
set ip route default Setting of default gateway
show ip config Display of network information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
59/541
Administration Ports
3-9
General Privilege Save
set ip route
Setting of static route
Sets a static route.
Input format P1 P2 P3 P4
Parameters P1: Routing domain (1 to 32)
P2: Destination address
P3: Subnet mask
P4: IP address (next hop)
Default value None
Usageconditions
You cannot use the network addresses set in the "set ip address inband" command(Setting of inband IP address) and "set ip address outband" command (Setting ofoutband IP address).
You cannot set 0.xxx.xxx.xxx/127.xxx.xxx.xxx and 224.xxx.xxx.xxx to 255.xxx.xxx.xxxas the IP address. ("xxx" is any number.)
If you set 0 or 1 to all bits of the host part as the gateway address or set 1 to all bits asthe destination address, this setting may not provide correct communication.
You cannot set the network addresses 192.168.128.0/24 and 192.168.129.0/24 as the
destination address. Also, you can set the gateway address for the network address192.168.128.0/24 or 192.168.129.0/24 but this setting does not provide correctcommunication.
Note If you log in via telnet communication, the login session close confirmation message isoutput.
Input example *Switch# set ip route 1 1.2.3.4 255.255.255.0 10.20.30.40*Switch#
Output item
Relatedcommands
set ip address out-band Setting of outband IP address
clear ip address out-band Clearing of outband IP address
clear ip route Clearing of static route
show ip config Display of network information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
60/541
Administration Ports
3-10
General Privilege Save
show ip config
Display of network information
Shows network information for outband/inband.
Input format None
Parameter None
Default value None
Usage condition 0.0.0.0 is shown in unset IP address and subnet mask.
Note None
Input example *Switch# show ip configIP Table
========
Management Port MAC Address IP Address Netmask
----------------------------------------------------------------------
out-band 00:0b:6d:02:31:4b 10.10.10.10 255.255.255.0
in-band 00:0b:6d:02:31:4c 0.0.0.0 0.0.0.0
IP Routing Table
================
Destination Gateway
Index Address Netmask Address Port
------------------------------------------------------------------
- 0.0.0.0 0.0.0.0 10.10.10.100 out-band
*Switch#
Output items Management Port: OSS port type
MAC Address: MAC address
IP Address: IP address
Netmask: Subnet mask
Index: Routing domain
Destination Address: Destination address
Gateway Address: Gateway address
Port: Band
out-band: Outband communication
in-band: Inband communication
-: No band
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
61/541
Administration Ports
3-11
Relatedcommands
set ip address out-band Setting of outband IP address
clear ip address out-band Clearing of outband IP address
set ip route default Setting of default gateway
clear ip route default Clearing of default gateway
set ip route Setting of static route
clear ip route Clearing of static route
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
62/541
Administration Ports
3-12
General Privilege Save
clear ip route
Clearing of static route
Clears a static route.
Input format P1
Parameter P1: Routing domain (1 to 32)
Default value None
Usage condition None
Note After this command is entered, execution is confirmed.
Input example *Switch# clear ip route 1Would you like to terminate remote session : (Y/N) : y
*Switch#
Output item
Relatedcommands
set ip route Setting of static route
show ip config Display of network information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
63/541
Administration Ports
3-13
General Privilege Save
set out-band speed
Setting of outband port speed/communication direction
Sets outband port speed/communication direction.
Input format - Specifying port speed (Auto-negotiation)
P1 (auto)
- Specifying the following port speed
-10m-half
-10m-full
-100m-half
-100m-full
P1 (10m-half | 10m-full | 100m-half | 100m-full) [P2]
Parameters P1: Port speed { 10m-half | 10m-full | 100m-half | 100m-full | auto }
10m-half: 10Mbps and Half Duplex
10m-full: 10Mbps and Full Duplex
100m-half: 100Mbps and Half Duplex
100m-full: 100Mbps and Full Duplex
auto: Auto-negotiation
When 10m-half, 10m-full, 100m-half, or 100m-full is specified in P1.
P2: Interface { mdi | mdi-x }
mdi: MDI modemdi-x: MDI-X mode
* When P2 is omitted, mdi is assumed.
Default value None
Usage condition None
Note If you log in via telnet communication, the login session close confirmation message isoutput.
Input example *Switch# set out-band speed auto*Switch#
Output item
Relatedcommand
show out-band information Display of outband port setup information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
64/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
65/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
66/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
67/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
68/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
69/541
Administration Ports
3-19
General Privilege Save
clear in-band vid
Clearing of in-band port VLAN
Clears an in-band port VLAN.
Input format None
Parameter None
Default value None
Usage condition None
Note None
Input example *Switch# clear in-band vid*Switch#
Output item
Relatedcommands
show in-band information Display of in-band port setup information
set ip address in-band Setting of in-band IP address
clear ip address in-band Clearing of in-band IP address
set ip route default Setting of default gateway
set ip route Setting of static route
set in-band admin Block/unblock of in-band port
set in-band vid Setting of in-band port VLAN
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
70/541
Administration Ports
3-20
General Privilege Save
ping
Checking of connection
Checks if connection with the host is correct. To cancel the connection test halfway, press Ctrl + c keycombination.
Input format P1 [P2]
Parameters P1: IP address
P2: Execution count (1 to 2147483647)
* When P2 is omitted, 4 times are assumed.
Default value None
Usageconditions
To cancel the connection test, press Ctrl + c .
You cannot set 0.xxx.xxx.xxx/127.xxx.xxx.xxx and 224.xxx.xxx.xxx to 255.xxx.xxx.xxxas the IP address. ("xxx" is any number.) Also, you can set the network addresses192.168.128.0/24 and 192.168.129.0/24 but this setting does not provide correctcommunication.
Note None
Input example *Switch# ping 192.168.1.212PING 192.168.1.212: 56 data bytes
64 bytes from 192.168.1.212: icmp_seq=0 ttl=255 time
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
71/541
Ports
4-1
4 Ports
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
72/541
Ports
4-2
General Privilege Save
set port admin
Setting of port blocking/unblocking
Blocking a port stops its operation, resulting in link down and communication unavailable. Unblocking itenables its operation.
Input format P1 P2
Parameters P1: Port number (1 to 26, 33 to 48) (Multiple values can be specified.)
P2: Port blocking/unblocking setting { enable | disable }
enable: Port unblocking
disable: Port blocking
Default value P2: enable
Usage condition When port blocking is set, the "LINK DOWN" message may be displayed. When portunblocking is set, the "LINK UP" message may be displayed. Whether "LINK DOWN"or "LINK UP" is displayed depends on the physical connection status of the set port.
Note None
Input example *Switch# set port admin 1 enable
*Switch#
Output item
Relatedcommand
show port information Display of port setting and status information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
73/541
Ports
4-3
General Privilege Save
set port speed
Setting of port speed and MDI/MDI-X
Sets a port speed and electrical interface (MDI/MDI-X) switching. If auto-negotiation is set as the portspeed, you cannot set MDI/MDI-X because the interface is automatically switched.
Input formats - Setting auto
P1 P2 (auto)
- Specifying the following port speed
- 10m-full
- 100m-full
- 1000m-fullP1 P2 (10m-full|100m-full|1000m-full) [P3]
Parameters P1: Port number (17 to 26) (Multiple values can be specified.)
P2: Port speed { 10m-full | 100m-full | 1000m-full | auto }
10m-full: 10Mbps and Full Duplex
100m-full: 100Mbps and Full Duplex
1000m-full: 1000Mbps and Full Duplex
auto: Auto-negotiation
When 10m-full, 100m-full, or 1000m-full is specified in P2.
P3: Interface { mdi | mdi-x }
mdi: MDI mode
mdi-x: MDI-X mode
* When omitted: mdi-x
Default value P2: auto
Usage condition - We recommend you to set auto-negotiation in the GbE ports
- The port (line) speed cannot be changed when an aggregation group is specified.
Notes If 100m-full is set for the FE port, SPEED-LED always goes on without reference to theport status.
If the port speed is fixed at 1000 Mbps for the GbE port (electrical interface), 1000Mbps fixed connection is performed using auto-negotiation. For connection with anassociated device that performs 1000 Mbps fixed connection without auto-negotiation,1000m-full link may become unstable. In 1000 Mbps connection, auto is always set formdi/mdi-x because auto-negotiation is always used.
For the GbE port (optical interface), auto-negotiation is not used in 1000m-full setting.However, if the associated device performs 1000 Mbps fixed connection using auto-negotiation, link may become unstable.
For the GbE port (optical interface), mdi/mdi-x setting is ignored.
Input example *Switch# set port speed 17 10m-full mdi*Switch#
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
74/541
Ports
4-4
Output item
Relatedcommand
show port information Display of port setting and status information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
75/541
Ports
4-5
General Privilege Save
set port type
Setting of GbE port media
Specifies a port (100BASE-TX/1000BASE-T or 1000BASE-X) used in the GbE port.
Input format P1 P2
Parameters P1: Port number (25 to 26) (Multiple values can be specified.)
P2: Interface type { electric | optical }
electric: 100BASE-TX/1000BASE-T
optical: 1000BASE-X
Default value P2: electric
Usage condition None
Note None
Input example *Switch# set port type 25 electric*Switch#
Output item
Relatedcommand
show port information Display of port setting and status information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
76/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
77/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
78/541
Ports
4-8
General Privilege Save
set port link-trap
Setting of SNMP link trap transmission
Sets whether to enable or disable SNMP link trap transmission.
This setting corresponds to ifLinkUpDownTrapEnable setting in the standard MIB ifMIB group.
Input format P1 P2
Parameters P1: Port number (1 to 26, 33 to 48) (Multiple values can be specified.)
P2: SNMP link trap transmission setting { enable | disable }
enable: Enables SNMP link trap transmission
disable: Disables SNMP link trap transmission
Default value P2: enable
Usage condition None
Note None
Input example *Switch# set port link-trap 1 enable*Switch#
Output item
Relatedcommand
show port information Display of port setting and status information
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
79/541
Ports
4-9
General Privilege Save
set port frame
Setting of port frame
Sets a port frame.
Input formats - Specifying the frame type E1/T1
P1 (e1|t1) [P2] [P3]
- Specifying the frame type SDH/SONET
P1 (sdh|sonet) P2 P3
Parameters P1: Frame type { e1 | t1 | sdh | sonet }
e1: E1 mode specification
t1: T1 mode specification
sdh: SDH physical frame layer
sonet: SONET physical frame layer
When e1 is specified in P1
P2: Line code { hdb3 | ami }
hdb3: HDB3
ami: AMI
* When P2 is omitted, hdb3 is assumed.
P3: Frame format { crc4 | crc4nocas | non-crc4 | unframed }
crc4: CRC4 multiframe
crc4nocas: CRC4 multiframe-no-CASnon-crc4: non-CRC4 (G.704 basic frame)
unframed: unframed
* When P3 is omitted, crc4 is assumed.
When t1 is specified in P1
P2: Line code { b8zs | ami }
b8zs: B8ZS
ami: AMI
* When P2 is omitted, b8zs is assumed.
P3: Frame format { esf | sf | sf-jpn | unframed }
esf: extended superframe
sf: superframesf-jpn: superframe-japanese
unframed: unframed
* When P3 is omitted, esf is assumed.
When sdh or sonet is specified in P1
P2: Port number (1)
P3: Idle cell method setting { idle | unassigned }
idle: idle cell idle cell method
unassigned: unassigned idle cell method
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
80/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
81/541
Ports
4-11
General Privilege Save
set port mode
Setting of port mode
Sets port mode.
Input format [P1 P2] [P3 P4] [P5 P6]
Parameters P1: TDM mode { tdm }
tdm: TDM mode specification
P2: TDM port number (1 to 16, 33 to 48) (Multiple values can be specified.)
P3: TDMoP mode { tdmop }
tdmop: TDMoP mode specification
P4: TDMoP port number (1 to 16, 33 to 48) (Multiple values can be specified.)
P5: ATMoP mode { atmop }
atmop: ATMoP mode specification
P6: ATMoP port number (1 to 16, 33 to 48) (Multiple values can be specified.)
Default values P1: tdm, P2: 1 to 16, 33 to 48
Usageconditions
If you enter a command specifying the same port number, an error occurs.
The previous values are retained for the omitted port numbers.
When the following settings are entered, an error occurs.set tdm group
set tdmop group
set ima group
set pvc static
set atm-shaper rate
If T1 mode is set for frame type and unframed is set for frame format in the port framesetting, an error occurs when the ATMoP mode is specified.
TDMoP mode and ATMoP mode have the different setting ranges for32T1E1H/32T1E1T line cards.
Line Card TDMoP Mode ATMoP Mode
32T1E1H 1 16 1 1632T1E1T 1 16, 33 48 -
Note None
Input examples *Switch# set port mode tdm 1-5 tdmop 6-10 atmop 11-16*Switch# set port mode tdmop 2-12
*Switch#
Output item
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
82/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
83/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
84/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
85/541
Ports
4-15
F2 Status Table
===============
Port MS-AIS MS-SD MS-RDI MS-ERR MS-REI
--------------------------------------------
1 --- --- --- --- ---
F3 Status Table===============
Port LOP P-AIS LCD
----------------------------
1 --- --- ---
*Switch# show port information 1,17,25
Line Port Information Table
===========================
Frame
Type Code Framing
------------------------
e1 hdb3 crc4
Port Link Alarm
Port Mode Admin Status Status
----------------------------------------
1 tdm enabled link-down los
Link Trap
Port Status
---------------
1 enabled
Cpusw Port Information Table============================
Port Link
Port Admin Speed Status MDI
------------------------------------------------------
17 enabled auto link-down auto mdi/mdi-x
Flowcontrol Flowcontrol
Port Configuration Status
----------------------------------
17 disabled disabled
Link Trap Protection Time Protection Time
Port Status Link Up(msec) Link Down(msec)
-------------------------------------------------
17 enabled 3000 500
Line2 Port Information Table
============================
Port Link
Port Admin Speed Status MDI
------------------------------------------------------
25 enabled auto link-down auto mdi/mdi-x
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
86/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
87/541
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
88/541
Ports
4-18
MS-RDI: MS-ERR detection status
---: No alarm
detect: Alarm detection
MS-ERR: MS-ERR detection status
---: No alarm
detect: Alarm detectionMS-REI: MS-REI detection status
---: No alarm
detect: Alarm detection
LOP: LOP detection status
---: No alarm
detect: Alarm detection
P-AIS: P-AIS detection status
---: No alarm
detect: Alarm detection
LCD: LCD detection status
---: No alarmdetect: Alarm detection
LinkStatus: Port physical link status
10m-full: 10 Mbps Full Duplex
100m-full: 100 Mbps Full Duplex
1000m-full: 1000 Mbps Full Duplex
1.5m-t1: T1 1.5 Mbps
2.048m-e1: E1 2.048 Mbps
155m: 155 Mbps
link-down: Link down
AlarmStatus: Alarm status
normal: No alarmlos: LOS detection
ais: AIS detection
lof: LOF detection
rai: RAI detection
lcd: LCD detection
LinkTrapStatus: SNMP trap transmission enable/disable setting
enabled: Enabled
disabled: Disabled
Port Speed: Port speed setting
10m-full: 10 Mbps Full Duplex
100m-full: 100 Mbps Full Duplex1000m-full: 1000 Mbps Full Duplex
auto: Auto-negotiation
MDI: Port MDI/MDI-X setting
mdi: MDI setting
mdi-x: MDI-X setting
auto mdi/mdi-x: Automatic recognition
FlowcontrolConfiguration: Flow control configuration
enabled: Flow control configuration enabled
disabled: Flow control configuration disabled
auto: Determined from alignment with the associated device
FlowcontrolStatus: Flow control statusenabled: Flow control enabled
disabled: Flow control disabled
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
89/541
Ports
4-19
TypeStatus: Current line type
electric: Electric module
optical: Optical module
---: Unsupported line (port) type
TypeConfiguration: Line (port) type settingelectric: Electrical line (port) selected
optical: Optical line (port) selected
SFPType: Type of optical module currently being used
1000BASE-SX: 1000BASE-SX module
1000BASE-LX: 1000BASE-LX module
1000BASE-ZX: 1000BASE-ZX module
1000BASE-BX10-D: 1000BASE-BX10-D module
1000BASE-BX10-U: 1000BASE-BX10-U module
OC3-SI15: OC3 Singlemode Interreach 15 Km
OC3-SL40: OC3 Singlemode Longreach 40 Km
OC3-SL80: OC3 Singlemode Longreach 80 KmOther: Unsupported optical module
unmount: Optical module not inserted
TxError: Optical module output error detection status
normal: No output error occurred
fail: An output error occurred
RxError: Optical module input error detection status
normal: No input error occurred
fail: An input error occurred
SFP Fault: SFP fault status
normal: No fault
fault(XXXXXXXX): Fault (fault information)SFPVendorInformation: Optical module vendor information
Vendor Name: Manufacturer name
Vendor OUI: OUI
Vendor Part Number: Manufacturing number
Vendor Revision: Version
Vendor Serial Number: Serial number
Relatedcommands
set port admin Setting of port blocking/unblocking
set port speed Setting of port speed and MDI/MDI-X
set port type Setting of GbE port media
set port flowcontrol Setting of flow control
set port protection-time Setting of port link down/recovery detection time
set port link-trap Setting of SNMP link trap transmission
set port frame Setting of port frame
set port clock Setting of ATM transmission path clock
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
90/541
Ports
4-20
General Privilege Save
set port cable-length
Setting of port cable length
Sets port cable length.
Input format - Specifying cable length (short)
P1 P2 (short) [P3]
- Specifying cable length (default)
P1 P2 (initial)
Parameters P1: Port number (1 to 16, 33 to 48) (Multiple values can be specified.)
P2: Length type { short | initial }short: short
initial: default
When short is specified in P2.
P3: Cable length { 133ft | 266ft | 399ft | 533ft | 655ft }
133ft: 133 ft
266ft: 266 ft
399ft: 399 ft
533ft: 533 ft
655ft: 655 ft
* When P3 is omitted, 133ft is assumed.
Default value P2: short, P3: 133ft
Usage condition The frame type needs to be set to the T1 mode.
Note None
Input examples *Switch# set port cable-length 3 short*Switch# set port cable-length 10-12,14-16 short 399ft
*Switch# set port cable-length 5 initial
*Switch#
Output item
Relatedcommands
set port frame Setting of port frame
set port mode Setting of port mode
show port cable-length Display of port cable length settings
-
7/27/2019 Pasolink Neo Te Cx2200_command Reference Ver_02.05
91/541
Ports
4-21
General Privilege Save
show port cable-length
Display of port cable length settings
Shows port cable length settings.
Input format [P1]
Parameter P1: Port number (1 to 16, 3