Download - PacScan 300 Series Brochure
-
PACSCAN 300 S
ERIES
DIGITA
L BIOMETRIC RULE
R
PacScan 300 SeriesDigital Biometric Ruler
Over 30 years of leadership in ophthalmic ultrasound brings you the PacScan 300 series, portable, digital biometric ruler.
Sonomed Escalon AccuracyA combination of high frequency, low noise probes and proprietary algorithms enables scan capture immediately upon applanation along the visual axis with precise measurement of corneal thickness, ACD, lens thickness, and axial length.
Sonomed Escalon UsabilityIntuitive interface, customized set-up, precise algorithms, and advanced hardware designs enable quick and easy examination of differ-ent eye types.
Sonomed Escalon ReliabilityConsistent and accurate results, time after time, year after year, we build unparalleled quality into every ultrasound system. Sonomed Escalon is still supporting instruments manu-factured over 20 years ago.
-
Features: Touch screen for easy operationEasy automatic calibration functionsSonomed Escalon dependability and accuracy
1. General:
Models: 300A A-Scan Only300P Pachymeter Only300AP A-Scan/Pachymeter
PacScan 300 Series Features: Touch Screen User Interface Large High Contrast LCD 5 Programmable User Profiles Portable Design Weighing 6 lbs (3 kg) Scan Viewer Archiving Software Power Requirements: PacScan System: 5W/90-250VAC Optional Printer: 9W/90-250VAC
2. A-Scan:
Scan Modes: Direct Contact/Immersion 5 Examination Modes: Cataract Dense Cataract Aphakic Pseudophakic (5 settings) Manual Review Screen for A-Scan Measurement Review Capability
Measurements: ACD, Lens, Vitreous, and AXL Individual Zone Velocities Average with Standard Deviations
Formulas: Available IOL Formulas: Binkhorst Regression-II Theoretic/T Holladay Hoffer-Q Haigis
Post-Refractive IOL Formulas: Latkany Myopic Regression Latkany Hyperopic Aramberri Double-K
Accuracy: Clinical Accuracy 0.1mm Electrical Accuracy 0.0484mm
A-Scan Probe Styles: Standard A-Scan Probe for Hand-Held, Immersion, or Slit Lamp Mounted Application
Soft-Touch A-Scan Probe for Hand-Held Use Minimizing Corneal Compression
3. Pachymeter:
Scan Modes: Map 1: 1 Point/Single Scan Map 2: 1 Point/Multiple Scans Map 3: 5 Point/Single Scan Map 4: 5 Point/Multiple Scans CCT Corrected IOP
Measurements: Variable Corneal Velocity Automatic Sensing Algorithm Measure Review Mode 256 Scan Average with Standard Deviation Measurement Accuracy Test (1 Micron)
Specifications: 125-1000 Micron Range Clinical Accuracy 5 Microns Electronic Accuracy 1 Micron Pachymeter Probe Styles: 20 MHz Straight Pachymeter Probe for Use When Patient is in Sitting Position
20 MHz 45 Degree Angled Pachymeter Probe for Use When Patient is in Supine Position
01
07
02
06
03
04 05 06
01 Model 300AP A-Scan / Pachymeter
02 Model 300A A-Scan Only
03 Model 300P Pachymeter Only
04 Direct Contact A-Scan Probe
05 Soft-Touch A-Scan Probe
06 Adjustable Legs for Angled Viewing from 0 to 45 Degrees
07 20 MHz Straight Pachymeter Probe
08 20 MHz 45 Degree Angled Pachymeter Probe
Sonomed Escalon, 1979 Marcus Avenue C105, Lake Success, NY 11042 Tel 800-227-1285 Fax 516-354-0900 www.sonomedescalon.com
SE-U-0201-A