INSIDE DIAMETER (DIM)
NOT IN CONTRACT
MISCELLANEOUSMISC
ELEVATIONEACH
ELECTRICALEXTERIOR
ELECELEVEA
NEG
NTSNONIC
MSN
NEGATIVE
NOT TO SCALENUMBER
NORTHMACHINE SCREW
CONCRETECOLUMNCONCRETE MASONRY UNITCLEARCEILING
DOUBLECONTINUOUS
DIMENSIONDOWN
DIAGONALDIAMETER
DRAWING
DIMDN
DWG
DBL
DIAGDIA
CONCCONT
CMUCLRCLG
COL
LINEARLINLTG
MAXMBMECHMFRMIN
MATL
MACHINE BOLTMECHANICALMANUFACTURERMINIMUM
LIGHTING
MAXIMUMMATERIAL
IDIN
HT HEIGHT
INCH
WF WIDE FLANGE (STEEL)
W/OW/
WDWITHOUTWOOD
WITH
GYPSUM WALLBOARD
FIRE EXTINGUISHER
FIXTURE
FACE OF CONCRETE
GALVANIZED SHEET METAL
FACE OF FINISHFOF
ADJ ADJACENT
CERAMIC TILE
APPROXIMATE
ABOVE FINISH FLOOR
ALTERNATEALUMINUM
BOTTOMBLOCK, BLOCKINGBUILDINGBOARD
ARCHITECTURAL
CAST IRON
CATCH BASINCTCI
BLDG
BOTBLK
CB
APPROXARCH
BD
AFF
ALTAL
GYP BDGSMGND
HMHORZ
HOLLOW METALHORIZONTAL
GROUND
FOS
GALV GALVANIZED
GAUGEGALLON
GENERAL
FACE OF STUDFEET, FOOTFOOTING
ACOUSTICAL CEILING TILEACCESS OR ACCESSIBLE
NUMBERPENNYEXISTING
AREA DRAIN
ACSACTAD
d#O
(E)(N) NEW
&
C
FLEX
FLUORFOC
FE
FIXTFLEXIBLEFLOORFLUORESCENT
FINISH (ED)
FLOOR DRAIN
FABRICATE
FOUNDATION
CONTRACTOR INSTALLED
PERFOFOI
PERFORATEDOWNER FURNISHED & OWNER INSTALLED
ODOFCI
OC
OWNER FURNISHEDOUTSIDE DIAMETERON CENTER(S)
W WEST
EXT
GAL
GEN
FTGGA
FT
FLR
FIN
FD
FAB
FDN
UONVERTVDFG VERTICAL GRAIN DOUGLAS FIR
UNLESS OTHERWISE NOTEDVERTICAL
STRT STRUCTURAL
THRU
TYPTP
SUSPT&G
THROUGH
TOP OF PAVEMENTTYPICAL
SUSPEND; SUSPENDEDTONGUE AND GROOVE
SPDSPEC
STDSSTSSD
STL
SLDSMD
SIM
SEE PLUMBING DWGS.SPECIFICATIONSSEE STRUCTURAL DWGS.STAINLESS STEEL
STEELSTANDARD
SEE LANDSCAPE DWGS.SEE MECHANICAL DWGS.
SIMILAR
SCDSCHED
SHT
SED
REQD
SSEE CIVIL DRAWINGSSCHEDULE; SCHEDULEDSEE ELECTRICAL DWGS.
SHEET
SOUTH
REQUIRED
PT
REINFREFRDRCP
PROPPREFABPLY
REINFORCED
REFLECTED CEILING PLANROOF DRAINREFERENCE
PREFABRICATE(D)PROPERTY
PLYWOOD
PERP PERPENDICULAR
DIAMETER OR ROUNDCENTERLINEANGLEAND
ANODIZEDANOD
AMERICAN SOCIETY FORASTM
AVERAGEAVG
AIRCONDITIONINGAC
TESTING & MATERIALS
BETWEENBTWBUILT-UP ROOFBURCABINETCAB
DRINKING FOUNTAINDEMOLISH
DFDEMO
DOORDR
FIRE ALARM CONTROL PANELFACPFLOOR AREA RATIOFAR
FINISHED FLOOR ELEVATIONFFE
GROUND FAULT CIRCUIT INTERRUPTEDGFCI
HB HOSE BIB
INFO INFORMATIONINSUL INSULATIONLAV LAVATORYLB POUND
PL PLATEPLAM PLASTIC LAMINATEPLBG PLUMBING
PRESSURE TREATED
PSI POUNDS PER SQUARE INCHPTD PAINTED
QTY QUANTITY
RESIL RESILIENTRO ROUGH OPENINGRWL RAIN WATER LEADER
SF SQUARE FOOT
TOC TOP OF CURB
TW TOP OF WALL
WIN WINDOWYD YARD
LF LINEAR FEET
A
A
05
K02
B05
W06
A21
12.01
N
E
S
W
00.00
00
A-123123 SF
12.01
12.01
C-01-a
W07
+ 8'-0"
CASEWORK TYPE
PREFIX DESIGNATES SPECIFICATIONDIVISION
REFER TO CASEWORK SCHEDULE
(OR CONTROL OR DATUM POINT)
MATCHLINE
SHEET KEYNOTE
PRODUCT KEYNOTE
WORK POINT
REFER TO DOOR SCHEDULE
REFER TO WINDOW SCHEDULE
REFER TO WALL TYPE SHEET
ASTERISK INDICATES PANIC HARDWARE
WINDOW NUMBER
WALL TYPE
DOOR NUMBER
EXTERIOR ELEVATION KEY
DETAIL NUMBERDETAIL SHEET
ELEVATION NUMBER
ELEVATION SHEET
SECTION KEY
SECTION NUMBERSECTION SHEET
DETAIL KEY
ROOM IDENTIFICATION
ROOM AREA [SQUARE FEET]
INTERIOR ELEVATION KEY
ELEVATION ORIENTATION
ELEVATION NUMBER
ELEVATION SHEET
ROOM NAME
ROOM NUMBER
GRID-LINE INDICATION
REFER TO SIGNAGE SCHEDULE
SIGNAGE NUMBER
SIGN LETTERROOM NUMBERBUILDING LETTER
ACCESSORY LETTERREFER TO ACCESSORY SCHEDULE
REFER TO WALL TYPE SHEET. SEE PLANS,EXTERIOR, & INTERIOR ELEVATIONS FORLOCATIONS.
WALL TYPE (ABOVE TYPICAL WALL)
FLUSH TRANSITIONBETWEEN ADJACENT SURFACES
CEILING HEIGHT
DIMPOINT
DIMENSION POINTDIM POINT NOTATION IS THE INTERSECTIONOF THE CENTER LINES OF THE STUDS OFEACH WALL ASSEMBLY
CLASSROOM
12.01
*
1. COORDINATE LAYOUT DIMENSIONS INDICATED ON THE STRUCTURAL,ELECTRICAL DRAWINGS WITH THOSE INDICATED ON THE ARCHITECTURALDRAWINGS. REPORT ALL DISCREPANCIES TO THE ARCHITECT BEFOREPROCEEDING WITH THE WORK.
2. IN THE EVENT THAT CERTAIN FEATURES OF THE NEW CONSTRUCTION ARENOT FULLY SHOWN IN THE CONSTRUCTION DOCUMENTS, THEIRCONSTRUCTION SHALL BE OF THE SAME CHARACTER AS SIMILARCONDITIONS THAT ARE SHOWN.
3. CHECK AND VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTINGCONDITIONS ON THE PROJECT SITE BEFORE THE WORK BEGINS. NOTIFY THEARCHITECT OF ANY DISCREPANCIES TO THE CONDITIONS SHOWN IN THECONTRACT DOCUMENTS BEFORE CONSTRUCTION BEGINS.
4. EXISTING CONDITIONS SHOWN ON THE DRAWINGS WERE OBTAINED FROMTHE OWNER-PROVIDED SURVEY DRAWINGS. THE ORIGINAL SURVEYS AREPROVIDED AS A REFERENCE TO THESE BID DOCUMENTS. VERIFY ALL EXISTINGCONDITIONS AND NOTIFY THE ARCHITECT OF ALL DEVIATIONS BEFOREPROCEEDING WITH THE WORK.
5. GELFAND PARTNERS ARCHITECTS HAS PREPARED THESE DOCUMENTSONLY FOR THE IMPROVEMENTS SPECIFIED, DETAILED, INDICATED, OR SHOWNAS NEW WORK AND ASSUMES NO RESPONSIBILITY FOR OTHERCONSTRUCTION, MATERIAL, OR EQUIPMENT NOTED, INDICATED, OR SHOWNAS "EXISTING" OR AS "PROVIDED BY OTHERS." UNLESS OTHERWISEINDICATED OR NOTED, GELFAND PARTNERS ARCHITECTS HAS NEITHERCHECKED NOR VERIFIED THE STRUCTURAL INTEGRITY, QUALITY OFCONSTRUCTION, ACCESSIBILITY TO, EGRESS FROM, OR DESIGN OF THEEXISTING CONSTRUCTION AND ANY OTHER WORK NOT INCLUDED AS PART OFTHE IMPROVEMENTS SPECIFIED, DETAILED, OR SHOWN ON THESEDOCUMENTS.
6. PROVIDE UL, GA, CBC, OR EQUAL LISTING NUMBERS FOR ALL FIRE-RATEDCEILING / FLOOR, ROOF, WALL, AND STRUCTURAL FRAME ASSEMBLIES. THECOMPONENTS AND INSTALLATION DETAILS SUCH AS NAILING SCHEDULESSHALL BE AS SHOWN ON PLANS AND MUST CONFORM IN EVERY PARTICULARWITH THE UL, GA, CBC, OR EQUAL LISTING NUMBERS SPECIFIED. CUSTOMDESIGNS WHICH COMBINE COMPONENTS FROM DIFFERENT APPROVEDDESIGNS BUT HAVE NOT BEEN TESTED AS A COMPLETE ASSEMBLY WILL NOTBE ACCEPTABLE.
7. PENETRATIONS OF PIPES, CONDUITS, ETC., IN WALLS REQUIRINGPROTECTED OPENINGS SHALL BE FIRE STOPPED. FIRE STOP MATERIAL SHALLBE A TESTED ASSEMBLY APPROVED BY THE STATE FIRE MARSHAL.
8. ADEQUATE ENGINEERING OBSERVATION AND TESTING SHALL BE PROVIDEDDURING CONSTRUCTION BY INSPECTOR OF RECORD PER TITLE 24.
9. DO NOT SCALE DIMENSIONS FROM PLANS. USE WRITTEN DIMENSIONS.WHERE NO DIMENSION IS PROVIDED, CONSULT THE ARCHITECT FORCLARIFICATION BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR ISRESPONSIBLE FOR ALL DIMENSIONS.
10. DRAWINGS AND SPECIFICATIONS REPRESENT FINISHED CONSTRUCTION.U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODSOF CONSTRUCTION.
11. NO DEVIATION FROM THE APPROVED DRAWINGS AND SPECIFICATIONS ISPERMITTED WITHOUT THE PRIOR CONSENT OF THE ARCHITECT. WRITTENCONSENT IS SUBJECT TO DSA APPROVAL. THE ARCHITECT'S INTERPRETATIONOF THESE DOCUMENTS SHALL BE FINAL.
12. LARGER SCALE DRAWINGS GOVERN IN CASE OF CONFLICT WITH SMALLERSCALE DRAWINGS.
13. OMISSIONS OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THEDRAWINGS, NOTES, SPECIFICATIONS, AND DETAILS SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT AND RESOLVED BEFORE PROCEEDINGWITH THE WORK.
14. FOR ADDITIONAL REQUIREMENTS, SEE SPECIFICATIONS.
15. ALL ITEMS ARE NEW U.O.N.
16. WORK INDICATED AS "OWNER FURNISHED" (O.F.C.I.) SHALL MEET ALLAPPLICABLE CODES AND REGULATORY REQUIREMENTS INDICATED WITHINTHESE DOCUMENTS AND SHALL BE INSTALLED AND FULLY OPERATIONALPRIOR TO THE FINAL APPROVAL AND OCCUPANCY OF THIS PROJECT
OWNER:
ARCHDIOCESE OF SAN FRANCISCOONE PETER YORKE WAYSAN FRANCISCO , CA 94109T: (415) 614-5500 F:(415) 614-5555
ARCHITECT:
GELFAND PARTNERS ARCHITECTS165 10TH STREET, SUITE 100SAN FRANCISCO, CA 94103T: (415) 346-4040 F: (415) 346-4103CONTACT: KAREN GATES
STRUCTURAL ENGINEER:
TENNEBAUM-MANHEIM ENGINEERS414 MASON STSAN FRANCISCO, CA 94102T: (415) 772-9891 F: (415) 772-9893CONTACT: NANCY TENNEBAUM
MECHANICAL & PLUMBING / ELECTRICAL ENGINEER:
E DESIGN C582 MARKET STREET, SUITE 400SAN FRANCISCO, CA 94103T: (415) 963-4303 F: (415)963-4341CONTACT: HENRY CHAN, MARCUS TAM
CLIENT:
MISSION NEIGHBORHOOD CENTERS, INC.362 CAPP STSAN FRANCISCO, CA 94110T: (415) 206-7752CONTACT: MARIA BERMUDEZ
LOCATION:
1245 ALABAMA STSAN FRANCISCO, CA 94110
ZONING DISTRICT:
RH-2 - RESIDENTIAL - HOUSE, TWO FAMILY
ASSESSOR PARCEL NUMBER:
4269/027
HEIGHT & BULK DISTRICT:
40-X
HISTORIC RESOURCE STATUS:
NOT A HISTORIC RESOURCE
EXISTING PARKING:
NON ACCESSIBLE: 0ACCESSIBLE: 0
TOTAL: 0
PROPOSED BICYCLE PARKING:
CLASS 1 TYPE : 3CLASS 2 TYPE: 4
TOTAL: 7
EXISTING OCCUPANCY: FIRST FLOOR: E - 5,240 SFSECOND FLOOR: R-2 - 4,630 SF
PROPOSED OCCUPANCY: FIRST FLOOR: ESECOND FLOOR: R-2
CONSTRUCTION TYPE: VB
APPROVED CONDITIONAL USE# 2016-006613 CUA
PLANNING COMMISSION MOTION NO. 19841
SEE T0.04
Current Codes
2016 Building Standards Administrative Code, Part 1, Title 24 C.C.R.2016 California Building Code (CBC), Part 2, Title 24 C.C.R.
(2009 International Building Code and 2010 CaliforniaAmendments)2016 California Electrical Code (CEC), Part 3, Title 24 C.C.R.
(2008 National Electrical Code and 2010 California Amendments)2016 California Mechanical Code (CMC) Part 4, Title 24 C.C.R.
(2009 Uniform Mechanical Code and 2010 CaliforniaAmendments)2016 California Plumbing Code (CPC), Part 5, Title 24 C.C.R.
(2009 Uniform Plumbing Code and 2010 California Amendments)2016 California Energy Code (CEC), Part 6, Title 24 C.C.R.2016 California Fire Code, Part 9, Title 24 C.C.R.
(2009 International Fire Code and 2010 California Amendments)2016 California Green Building Standards Code (CALGreen), Part 11,Title 24 C.C.R.2016 California Referenced Standards, Part 12, Title 24 C.C.R.Title 19 C.C.R., Public Safety, State Fire Marshal Regulations.
2016 San Francisco Building Code Amendments2016 San Francisco Electrical Code Amendments2016 San Francisco Mechanical Code Amendments2016 San Francisco Plumbing Code Amendments2016 San Francisco Green Building Code Amendments2016 San Francisco Fire Code
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission DateBUILDING PERMIT 5/30/17
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:49 P
M T0.00
NOTES & GENERALINFORMATION
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
PRE APPLICATION NOTESABBREVIATION PROJECT NOTES
APPLICABLE CODESPROJECT TEAM
SYMBOLS
REGIONAL MAP VICINITY MAPNN
PROJECT DATA
SHEET LIST
PARKING INFORMATION
SCOPE OF WORK
1245 ALABAMA ST
24TH ST
25TH ST
ALABAMA ST
FLOR
IDA ST
1245 ALABAMA ST
PLANNING
SEE TO.O3
-CHANGE OF OCCUPANCY AT 2ND FLOOR FROM R-2 TO B.-TENANT IMPROVEMENT ON 2ND FLOOR INCLUDING FINISHES,FIXTURES, ELECTRICAL UPGRADES, PATH OF TRAVELIMPROVEMENTS-EGRESS PATH IMPROVEMENTS AT 1ST FLOOR.
CALGREEN
EXEMPT PER (CGBC 301.3)PERMIT VALUATION <$200,000
GeneralT0.00 NOTES & GENERAL INFORMATIONT0.01 EGRESS PLANST0.02 ACCESS COMPLIANCET0.03 PREAPPLICATION NOTEST0.04 CONDITIONAL USE PERMIT
ArchitecturalA1.00 EXISTING SITE PLANA2.00 FIRST FLOOR PLANSA2.01 SECOND FLOOR PLANSA4.00 EXTERIOR ELEVATIONSA5.00 ENLARGED TOILET PLAN & INTERIOR
ELEVATIONSA5.01 ENLARGED STAIR PLAN AND DETAILSA8.00 SCHEDULESA9.00 WALL TYPES AND DETAILSA10.01 TYPICAL SIGNAGE & ACCESSIBILITY
DETAILS
MechanicalMP0.01 MECHANICAL & PLUMBING TITLE SHEETMP2.01 SECOND FLOOR MECHANICAL/PLUMBING
DEMOLITION & NEW PLANSMT24.01 MECHANICAL TITLE 24 SHEET
ElectricalE0.00 ELECTRICAL TITLESHEETE2.01 SECOND FLOOR ELECTRICAL DEMOLITIONE2.02 SECOND FLOOR LIGHTING AND POWER
PLANSET24.1 TITLE 24 LIGHTING FORMSET24.2 TITLE 24 LIGHTING FORMS
WD DW
PARKING LOT
OPEN HARDCOURTS FOR ADJACENT SCHOOL100 - 2 100 - 2 300 - 1
180'-0" EXIT ACCESSTRAVEL DISTANCE
100 - 235 - 23
300 - 2
100 - 1300 - 1
100 - 235 - 1835 - 19
188 SF
(E) OFFICE
2
674 SF
(E)CLASSROOM
2
616 SF
(E)CLASSROOM
3
784 SF
(E)CLASSROOM
1
175 SF
(E)ACCESSIBLE
MEETINGROOM
112 SF
(E) OFFICE
99 SF
(E)STORAGE
863 SF
(E)SANCTUARY
TOREMAIN
115 SF
(E)ACCESSIBLERECEPTION
108 SF
(E)MECHANCIAL
ROOM
95 SF
(E)ACCESSIBLE
OFFICE 3
80 SF
(E)ACCESSIBLE
TOILET
329 SF
(E)WARMINGKITCHEN
52 SF
(E)STORAGE
2
635 SF
(E)ACCESSIBLE
ENTRY
2
1
2
23
19
2 1 1
1
18
ALAB
AMA
STRE
ET
130 SF
OFFICE
221
226 SF
WORKSHOP
219
118 SF
OFFICE
218
117 SF
OFFICE/WAITING
217
232 SF
COMPUTERLAB
214
116 SF
OFFICE
213
116 SF
OFFICE
212
121 SF
OFFICE
209
122 SF
OFFICE
208
121 SF
OFFICE
207
367 SF
OFFICE
205
138 SF
OFFICE
201
61 SF
OFFICE
222
CLOCLO
CLO
245 SF
MEETINGROOM
227
86 SF
OFFICE
229
69 SF
COPIER
211
114 SF
OFFICE /WAITING
216
TOILET
BALCONY
TOILETMOBILITY
TOILET
CLO
CLOCLO
244 SF
OFFICE
202
STAIR 1
STAIR 2
HALL 1
HALL 2
100 - 4100 - 3
HALL 1ROOM OCCUPANT LOAD201 2214 5216 2217 2218 2219 5221 2222 1227 (half) 8
TOTAL 29
100 - 2 100 - 2
100 - 2100 - 2
300 - 1
50 - 5100 - 2100 - 2100 - 250 - 5100 - 2
100 - 1
100 - 2
15 - 17
100 - 1
HALL 2ROOM OCCUPANTLOAD202 3205 4207 2208 2209 2211 1212 2213 2227 (1/2) 9229 1
TOTAL 28
ROOM NAME
ROOM #
AREA SF
### - #
OCCUPANT LOAD
OCCUPANT MULTIPLIER
EGRESS PATH
9
3 4 2 2 2
1
22
1
522
8
252
1
2
100 - 2
29 TOTAL
28 TOTAL
140' EXIT ACCESS TRAVEL DISTANCE
130' EXIT ACCESS TRAVEL DISTANCE
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
SHEET NOTES
KEYNOTES
LEGEND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission DateBUILDING PERMIT 5/30/17
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:51 P
M T0.01
EGRESS PLANS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1" = 10'-0"1
FIRST FLOOR EGRESS PLAN (E) TOREMAIN
1" = 10'-0"2 SECOND FLOOR EGRESS PLAN
5
1. MAXIMUM ALLOWABLE EXIT ACCESS TRAVEL DISTANCE :200' (CBC TABLE 1016.2)
2. EXISTING HORIZONTAL 2 HR SEPARATION BETWEENFLOOR 1 AND FLOOR 2 PER PERMIT 2014-1110-1104
WD DW
OFFICE
221
WORKSHOP
219
OFFICE
218
OFFICE/WAITING
217
COMPUTERLAB
214
OFFICE
213
OFFICE
212
OFFICE
209
OFFICE
208
OFFICE
207
OFFICE
205
OFFICE
201
OFFICE
222CLOCLO
CLO
MEETINGROOM
227
OFFICE
229
COPIER
211
OFFICE /WAITING
216
TOILET
BALCONY
TOILETMOBILITY
TOILET
CLO
CLOCLO
OFFICE
202
STAIR 1
STAIR 2
HALL 1
HALL 2
LEGEND
PARTIALLYACCESSIBLE
ACCESSIBLE PATH OF TRAVELPATH OF TRAVELIMPROVEMENTS
PROGRAM
175 SF
(E)ACCESSIBLE
MEETINGROOM
115 SF
(E)ACCESSIBLERECEPTION
95 SF
(E)ACCESSIBLE
OFFICE 3
80 SF
(E)ACCESSIBLE
TOILET
635 SF
(E)ACCESSIBLE
ENTRY
ALAB
AMA
STRE
ET
PARTIALLYACCESSIBLEPROGRAM ONSECOND FLOOR
LEGEND
ACCESSIBLE
PARTIALLYACCESSIBLEPROGRAM ONSECOND FLOOR
STAFFENTRY
PROGRAM
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:56 P
M T0.02
ACCESS COMPLIANCE
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1" = 10'-0"1 SECOND FLOOR ACCESS PLAN
1" = 10'-0"2 FIRST FLOOR ACCESS PLAN
1245 Alabama St
Office
2nd Floor
$156,000 x
x
x
1245 Alabama St
x
x
x
x
x
x
x
x
None Existing
Accessible programis shared with 1stFloor ChildcareCenter - see 1/ T0.02
Accessible programis shared with 1stFloor ChildcareCenter - see 1/ T0.02
None Existing
shared with 1st FloorChildcare Center -
A5.01 - StairsA8.00 - DoorScheduleA10.01 - SignageDetails
x
Family Resource Center
1245 Alabama Street
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 6:12
:44 P
M T0.02A
UNREASONABLEHARDSHIP
APPLICATION
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:58 P
M T0.03
PREAPPLICATIONNOTES
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
3:00 P
M T0.04
CONDITIONAL USEPERMIT
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
PROPERTY LINE
PROPERTY LINE
PR
OP
ERTY
LIN
E
PR
OP
ERTY
LIN
E65
.00'
125.00'
125.00'
65.0
0'
ALA
BAM
A S
T
LOADING ZONE
(3) TYPE 2 BIKE LOCKERS
(E) TWO STORY STRUCTURE - NO ADDITIONS
1245 ALABAMA STLOT 027OWNER: ARCHDIOCESE OF SAN FRANCISCO
(4) TYPE 1 BIKE PARKING
(E) SCHOOLLOT 28OWNER: ARCHDIOCESE OF SAN FRANCISCO
(E) CHURCHLOT 26OWNER: ARCHDIOCESE OF SAN FRANCISCO
LINE OF EDGE OF BUILDING
GARBAGE & RECYCLING
(E) CATCH BASINTO REMAIN
(E) CATCH BASINTO REMAIN
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
SHEET NOTES
KEYNOTES
LEGEND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:31 P
M A1.00
EXISTING SITE PLAN
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1" = 10'-0"SITE PLAN EXISTING TO REMAIN1
N
WD DW
?1 ?2 ?3 ?4 ?5 ?6 ?7
?A
?C
?D
?E
?F
?4.5 ?5.8
100D
(E) CLASSROOM 2 (E) CLASSROOM 3
(E) CLASSROOM 1(E) ACCESSIBLE MEETING
ROOM
(E) OFFICE (E) OFFICE (E) STORAGE
(E) SANCTUARY TOREMAIN
(E) WARMINGKITCHEN
(E) ACCESSIBLEENTRY
A5.012
W3
W3
100B
100A
100C
101A101B 101C
101D
AREA OF WORK
AREA OF WORK
?1 ?2 ?3 ?4 ?5 ?6 ?7
?A
?B
?C
?D
?E
?F
?4.5 ?5.8
A4.004
A4.001
A4.003
A4.002
(E) CLASSROOM 2 (E) CLASSROOM 3
(E) CLASSROOM 1
(E) ACCESSIBLE MEETINGROOM
(E) OFFICE
(E) OFFICE (E) STORAGE
(E) SANCTUARY TOREMAIN
(E) ACCESSIBLERECEPTION
(E) MECHANCIALROOM
(E) ACCESSIBLEOFFICE 3
(E) ACCESSIBLETOILET
(E) WARMINGKITCHEN
52 SF
(E)STORAGE
2
391
(E) ACCESSIBLEENTRY
STAFF ENTRY
A5.011
NEW WALL - WALL TYPE PER PLAN
EXISTING WALL
DEMO WALL
DEMO DOOR & FRAME
NOT IN CONTRACT - NO WORK
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
SHEET NOTES
KEYNOTES
LEGEND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission DateBUILDING PERMIT 5/30/17
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:34 P
M A2.00
FIRST FLOOR PLANS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1/8" = 1'-0"FIRST FLOOR PROPOSED PLAN2
1/8" = 1'-0"FIRST FLOOR DEMO PLAN1
?1 ?2 ?3 ?4 ?5 ?6 ?7
?A
?B
?C
?D
?E
?F
?4.5 ?5.8
(E) OPENING TO REMAIN
201201A
222
221220 219 218 217 216
232
223 225A
225B224 226B
226A 227A
227B 227D
227C
200F
215 214 213 212
211
210
230
231
209208207206205203202
X233229A
229B
200C 200D
200E
?1 ?2 ?3 ?4 ?5 ?6 ?7
?A
?B
?C
?D
?E
?F
?4.5 ?5.8
201201A
222
221220 219 218 217 216
223 225A
225B224 226B
226A
200F
215 214 213 212
211
210
230
231
209208207206205203202
229A
229B
200C 200D
200E
200A
OFFICE
221
WORKSHOP
219
OFFICE
218
OFFICE/ WAITING
217
OFFICE / WAITING
216COMPUTER LAB
214
OFFICE
213
OFFICE
212
OFFICE
209
OFFICE
208
OFFICE
207
OFFICE
205
OFFICE
201
OFFICE
222
CLO
225
CLO
223
CLO
224
MEETING ROOM
227
OFFICE
229
COPIER
211TOILET
226A
TOILET
201A
MOBILITY TOILET
226B
CLO
230
CLO
231CLO
210
OFFICE
202
STAIR 1
STAIR 2
HALL 1
HALL 2
227A
A5.001
227B
2
2
200B
201BA5.0010
(E) BATHROOM
228
(E) BATHROOM
227
(E) BEDROOM
202
(E) BEDROOM
205
(E) BEDROOM
207
(E) BEDROOM
208
(E) BEDROOM
209
(E) STORAGE
211
(E) BEDROOM
212
(E) BEDROOM
213
(E) BEDROOM
214
(E) BEDROOM
216
(E) BEDROOM
217
(E) BEDROOM
218
(E) BEDROOM
219
(E) BEDROOM
220
(E) BEDROOM
221
(E) STORAGE
222
(E) TOILET
201A
(E) BEDROOM
201
(E) STORAGE
223
(E) STORAGE
224
(E) STORAGE
225
(E) TOILET
226
(E) TOILET
229
(E) STAIR 2
(E) STAIR 1
(E) CLOSET
210
(E) BEDROOM
203
(E) BEDROOM
204(E) BEDROOM
206
(E) BEDROOM
215
(E) CLOSET
230
(E) CLOSET
231
NEW WALL - WALL TYPE PER PLAN
EXISTING WALL
DEMO WALL
DEMO DOOR & FRAME
NOT IN CONTRACT - NO WORK
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
SHEET NOTES
KEYNOTES
LEGEND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission DateBUILDING PERMIT 5/30/17
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:36 P
M A2.01
SECOND FLOOR PLANS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1/8" = 1'-0"SECOND FLOOR DEMO PLAN1
1/8" = 1'-0"SECOND FLOOR PROPOSED PLAN2
FLOOR 10"
FLOOR 210' - 0"
ATTIC19' - 0"
GROUND LEVEL-1' - 11"
?1?2?3?4?5?6?7 ?4.5?5.8
FLOOR 10"
FLOOR 210' - 0"
ATTIC19' - 0"
GROUND LEVEL-1' - 11"
?A ?B ?C ?D ?E ?F
ADJACENT CHURCH
FLOOR 10"
FLOOR 210' - 0"
ATTIC19' - 0"
GROUND LEVEL-1' - 11"
?1 ?2 ?3 ?4 ?5 ?6 ?7?4.5 ?5.8
FLOOR 10"
FLOOR 210' - 0"
ATTIC19' - 0"
GROUND LEVEL-1' - 11"
?A?B?C?D?E?F
ADJACENT CHURCH
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
SHEET NOTES
KEYNOTES
LEGEND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:38 P
M A4.00
EXTERIOR ELEVATIONS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1/8" = 1'-0"NORTH ELEVATION1
1/8" = 1'-0"WEST ELEVATION2
1/8" = 1'-0"SOUTH ELEVATION3
1/8" = 1'-0"EAST ELEVATION4
A5.00 2A5.00
3
A5.00
4
A5.005
4' - 0
" CLR
30"X48" CLR
60"X56" CLR
A5.00
6
9
8
7
9' - 2"
4' - 1
"
60" MIN.
1' - 6
"
15.02
15.03
15.02
15.03
1' - 6
"
RELOCATE HANGER ANDPLUMBING AS REQUIREDTO MEET CLEARANCES
REPLACE @ EXISTING LOCATION
10.04
10.02
10.03
10.05
10.05
1' - 0" CLR
10.02
226B
226A
10.03
1' - 6" CLR0' -
11 13
/16"
W1
FLOOR 210' - 0"
?D
2ND FL CEILING18' - 0"
15.02
10.02
10.04
FLOOR 210' - 0"
?4
2ND FL CEILING18' - 0"
10.0415.03
15.01
10.01
FLOOR 210' - 0"
?4
2ND FL CEILING18' - 0"
15.02
10.02
10.05
FLOOR 210' - 0"
?D
2ND FL CEILING18' - 0"
10.01
15.01
10.05
FLOOR 210' - 0"
?4
2ND FL CEILING18' - 0"
15.03
15.01
10.04
10.03
15.02
10.01
FLOOR 210' - 0"
?C
2ND FL CEILING18' - 0"
10.01
15.03
15.01
FLOOR 210' - 0"
?4
2ND FL CEILING18' - 0"
10.05
FLOOR 210' - 0"
?C
2ND FL CEILING18' - 0"
15.02
10.03
201B
201A
15.0515.0110.05 10.03 10.04
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
SHEET NOTES
KEYNOTES
LEGEND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:40 P
M A5.00
ENLARGED TOILETPLAN & INTERIOR
ELEVATIONS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1/2" = 1'-0"MOBILITY ADULT TOILET ROOM1
1/2" = 1'-0"MOBILITY TOILET ELEVATION 12
1/2" = 1'-0"MOBILITY TOILET ELEVATION 23
1/2" = 1'-0"MOBILITY TOILET ELEVATION 34
1/2" = 1'-0"MOBILITY TOILET ELEVATION 45
1/2" = 1'-0"TOILET ELEVATION 56
1/2" = 1'-0"TOILET ELEVATION 67
1/2" = 1'-0"TOILET ELEVATION 78
1/2" = 1'-0"TOILET ELEVATION 89
10.01 MIRROR PER 1/A10.01 D10.02 GRAB BAR PER 1C/A10.0110.03 TOILET PAPER DISPENSER PER 1G/A10.0110.04 TOILET SEAT COVER DISPENSER10.05 PAPER TOWEL DISPENSER PER 1E/ A10.0115.01 WRAP EXPOSED PIPE WITH INSULATION15.02 ACCESSIBLE TOILET PER 1H/A10.0115.03 ACCESSIBLE LAVATORY PER 1A/A10.0115.05
1/2" = 1'-0"10 2ND FLOOR - EXISTING(1)
1. FOR TYPICAL ACCESSORY MOUNTING LOCATIONS, SEE 1/A10.01
4A5.01
5A5.01
A5.01
31' - 5 21/32"
ø 5'
- 0"
5' - 0
"
1' - 0"
3' - 7
3/8"
4' - 0
"
05.01
05.01
05.01
FLOOR 10"
FLOOR 210' - 0"
HALLWAY BEYOND1'
- 6"
1'-0" MIN 11" MIN3'
- 0"
05.01
05.02
FLOOR 10"
FLOOR 210' - 0"
1ST FLOOR CEILING9' - 0"
3' - 0
"
MATCH (E) TREAD11" MIN
TREAD DEPTH 3' - 0
"
1' - 0"
4' - 0
"
LOW WALL W/ WOOD TOP
FLOOR 10"
1
3' - 1
3/4"
3' - 0"
4' - 0
"
100D
?E
12A5.01
1'-11
" MIN
4" M
AX
1' MI
N
1'-0"
MIN
1'-11
" MIN
3' - 6" 3' - 6"05.01
05.02
05.0105.01
FLOOR 210' - 0"
05.01
3'-0"
T.O
. RAI
L
1'-0" MIN
3' - 0
"
1'-11" MIN
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
SHEET NOTES
KEYNOTES
LEGEND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:42 P
M A5.01
ENLARGED STAIR PLANAND DETAILS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1/4" = 1'-0"FIRST FLOOR DEMO STAIR 1 ENLARGED PLAN1
1/4" = 1'-0"FIRST FLOOR PROPOSED STAIR 2 ENLARGED PLAN2
1/2" = 1'-0"EXISTING STAIR AND NEW LANDING SECTION4
1/2" = 1'-0"NEW STAIR AND LANDING SECTION5
1/2" = 1'-0"Elevation 3 - a3
1/4" = 1'-0"FIRST FLOOR RCP DEMO6 1/4" = 1'-0"
FIRST FLOOR RCP PROPOSED7
1/4" = 1'-0"2ND FLOOR - EXISTING11
1/2" = 1'-0"Section 412
B
3' - 0"
6' - 8
"
Varies
6' - 8
"
0' - 1
0"
A
0' - 5"
0' - 6
"
FLOOR
C DOOR HARDWARE, TYPL 6' - 8
".
5' - 0".
C D AA
0' - 5"
0' - 6
"4'
- 0"
0' - 2
"
0' - 2"
2
6' - 8
"
2' - 8"
FLOOR
3' - 2
"
1
4' - 0
"
3' - 0"
GLAZING:
A FIRE RATED FIRELITE 90 MINB INT - TEMPERED
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:43 P
M A8.00
SCHEDULES
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1/4" = 1'-0"DOOR TYPES
DOOR SCHEDULE
LOCATION CODE DOOR DOOR
Type Mark ThicknessGlazing
Type
FRAME HARDWARE
H CloserH
Kickplate H Panic Comments
DETAILS DETAILS DETAILS SIGNAGE SIGNAGE
TAG INT/EXT RM. NAMEFIRE
RATING(N)/(E)DOOR
OPENING SIZEMTL. TYPE GROUP HEAD JAMB THRESHOLD
17/A10.01DETAIL VERBAGEWIDTH HEIGHT
FLOOR 1100A Exterior STAFF ENTRY - N 3' - 6" 6' - 8" HM A 0' - 1 3/4" - HM SET 01 Yes No No (E) EXIT STAIR DOWN100B Interior STAFF ENTRY 90 MIN N 5' - 0" 6' - 8" WD C 0' - 1 3/4" - HM SET 02 Yes Yes No -100C Interior STAFF ENTRY 90 MIN N 3' - 0" 6' - 8" WD A 0' - 1 3/4" - HM SET 03 Yes Yes No -100D Interior (E)
ACCESSIBLEENTRY
90 MIN N 3' - 0" 6' - 8" WD D 0' - 1 3/4" A HM SET 03 Yes Yes No 1G PUSH: CHILDCARE CENTERPULL: FAMILY RESOURCECENTER
101A Interior 90 MIN N 3' - 0" 6' - 8" WD A 0' - 1 3/4" - HM SET 04 Yes Yes No -101B Interior (E)
ACCESSIBLETOILET
90 MIN N 3' - 0" 6' - 8" WD A 0' - 1 3/4" - HM RE-USE (E) Yes Yes No (E)
101C Interior (E)ACCESSIBLEOFFICE 3
90 MIN N 3' - 0" 6' - 8" WD A 0' - 1 3/4" - HM RE-USE (E) Yes Yes No (E)
101D Interior (E) WARMINGKITCHEN
90 MIN N 3' - 0" 6' - 8" WD A 0' - 1 3/4" - HM SET 03 Yes Yes No -
FLOOR 2200A Interior HALL 2 - N 3' - 0" 6' - 8" WD B 0' - 1 3/4" B WD SET 05 No Yes No -200B Interior - N 3' - 0" 6' - 8" WD B 0' - 1 3/4" B WD SET 05 No Yes No -201B Interior TOILET - N 3' - 0" 6' - 8" WD A 0' - 1 3/4" - WD SET 06A No No No 1G ALL GENDER RESTROOM227A Interior MEETING
ROOM- N 2' - 8" 6' - 8" WD B 0' - 1 3/4" B WD SET 07 No Yes No 1G TBD
227B Interior MEETINGROOM
- N 2' - 8" 6' - 8" WD B 0' - 1 3/4" B WD SET 07 No Yes No 1G TBD
200C Interior STAIR 2 90 MIN E 3' - 0" 6' - 8" WD A 0' - 1 3/4" - - SET 08A No No -200D Interior STAIR 2 90 MIN E 3' - 0" 6' - 8" WD A 0' - 1 3/4" - - SET 08B No No -200E Interior STAIR 1 90 MIN E 3' - 0" 6' - 8" WD A 0' - 1 3/4" - - - No No -200F Exterior - E 2' - 6" 6' - 8" WD A 0' - 1 3/4" - - - No -201 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - No -201A Interior TOILET - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - No -202 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G203 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G205 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No -206 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No -207 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No -208 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No -209 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -210 Interior CLO - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -211 Interior COPIER - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -212 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -213 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -214 Interior COMPUTER
LAB- E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G
215 Interior COMPUTERLAB
- E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G
216 Interior OFFICE /WAITING
- E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G
217 Interior OFFICE/WAITING
- E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G
218 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -219 Interior WORKSHOP - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G220 Interior WORKSHOP - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 09 No Yes No 1G221 Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -222 Interior HALL 1 - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -223 Interior CLO - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -224 Interior - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -225A Interior CLO - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -225B Interior HALL 2 - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -226A Interior TOILET - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 06A No No No 1G ALL GENDER RESTROOM226B Interior HALL 2 - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - SET 06B No Yes No 1A ALL GENDER RESTROOM229A Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -229B Interior OFFICE - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -230 Interior HALL 2 - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -231 Interior HALL 2 - E 2' - 8" 6' - 8" WD A 0' - 1 3/4" - - - -Grand total: 49
1/4" = 1'-0"WINDOW TYPES
WINDOW SCHEDULE - PHASE 3
LEVEL TAG COUNTOPENING SIZE
FINISHHead
HeightGlazing
TypeSill
Height Operation TypeTypicalDetailWIDTH HEIGHT
FLOOR 1FLOOR 1 1 1 3' - 0" 4' - 0" 7' - 1 3/4" A 3' - 1 3/4" FIXED 36" x 48" 6/A10.00FLOOR 2FLOOR 2 2 2 2' - 8" 6' - 8" 6' - 8" B 0' - 0" FIXED 32" x 80"
GYPSUM BOARD
DOOR AS SCHEDULED
WOOD SHIM
WOOD CASING
(E) OR (N) HEADER, SSD
NOTE: SEE PLAN FOR WALL TYPE
(E) 5/8" GYP BD
(E) WD HEADER
(E) 1/2" GYP SHEATHING
7/8" CEMENT PLASTER OVERMETAL LATHE
2 LAYERS BUILDING PAPER - LAPOVER HM FRAME WEATHERFLANGE
HM DOOR FRAME W 2" WEATHERFLANGE
RAIN HOOD PER HARDWARESCHEDULE
PLASTER WEEP SCREED
GAP W/ 3/8" SEALANT - DO NOTOCCLUDE SCREED HOLES
EXPANSION FOAM INSULATION -INJECT INTO FRAME CAVITY
DOOR PER SCHEDULE
0' -
2"
0' - 1"
0' -
0 1/
4"
0' - 0 3/8"
VARIES
WEATHER STRIPPING
THERMAFIBER & FIRE CAULKING
(E) WOOD HEADER
SEE PLAN FOR WALL TYPE
1/2" M
IN
0' - 2
"
90 MINUTE RATED HM DOOR
90 MINUTE RATED HM FRAME
THERMAFIBER & FIRE CAULKING
(E) WOOD HEADER
SEE PLAN FOR WALL TYPE
1/2" M
IN
0' - 2
"
2 HR RATED FIRE-LITE FIRE RATEDGLAZING
2 HR RATED HM FRAME
WOOD STUD
FIBERGLASS BATT INSULATION R-13
5/8" TYPE 'X' GYP. BD.
5/8" TYPE 'X' GYP. BD.
1-HOUR RATED GA FILE NO. WP 3605
FIRE RATING 2-HOUR; GA FILE NO. WP 4230
SOUND RATING 52 (USG-810218)
2x4 STUDS AT 16" O.C.
(2) LAYERS 5/8" TYPE 'X'GYPSUM BOARD EACHSIDE OF WALL
SOUND ATTENUATIONBATT INSULATION
NOTE:SEE SPECIFICATIONS FORADDITIONAL INFORMATIONPERTAINING TO GYPSUMTYPES AND LOCATIONS;CORRIDORS, STAIRSHAFTS AND ELEVATORSHAFTS TO HAVEQUIETROCK; KITCHENS,BATHS, TRASH ROOM ANDLAUNDRY ROOMS TOHAVE PAPERLESSGYPSUM BOARD
WOOD STUD
SPRAY APPLIED FIRE-RESISTIVEMATERIAL
5/8" TYPE 'X' GYP. BD.
5/8" TYPE 'X' GYP. BD.
2-HOUR RATED UL FILE NO.
CONTRASTING COLORSTRIP AT TOP AND
BOTTOM TREAD,TYP.
2x12 STRINGERBEYOND [AT 30" O.C.,
TYP.]
2x12 P.T. STRINGERBEYOND [AT 30" O.C.,
TYP.]
7" M
AX
9/16"
MAX RADIU
S
1-1/4" MAX
0' - 2"
1 1/2" O.D. RAIL
RAIL BRACKETS
MIN 2" EMBEDMENT INTO BLOCK
+36"
A.F.
F
4X6 BLOCK WITH A34 CLIPS @ EACHEND
1-1/2" CLR
1-1/2
" CLR
LENGTH OF HANDRAIL EXTENSION:@ RAMP TOP AND BOTTOM,
TOP OF STAIR = 12"
@ BOTTOM OF STAIRS =12"+TREAD LENGTH
END OF SLOPE @ RAMP, BOTTOMOR TOP TREAD @ STAIR
0' -
1 1/
2"
0' -
0 1/
2"
TYP HANDRAIL BRACKET @EXISTING BLOCKING WHEREAVAILABLE, OTHERWISE 6'-0"O.C. PER DETAIL
WALL
1 1/2" OD SCHED 40 STEEL PIPEHANDRAIL
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission DateBUILDING PERMIT 5/30/17
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:45 P
M A9.00
WALL TYPES ANDDETAILS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
3" = 1'-0"INTERIOR WOOD DOOR HEAD - JAMB SIM2
3" = 1'-0"EXT DOOR HEAD @ WD STUD WALL1
3" = 1'-0"90 MINUTE RATED DOOR HEAD - JAMB SIM3
3" = 1'-0"2 HR WINDOW JAMB/ HEAD SIM - INTERIOR4
3" = 1'-0"INTERIOR PARTITION - WD STUDW1
3" = 1'-0"INT. WALL - 2-HOURW3
3" = 1'-0"INTERIOR WALL - 2-HOURW2
3" = 1'-0"STAIR NOSING DETAIL5
6" = 1'-0"TYPICAL HANDRAIL BRACKET6
3" = 1'-0"TYPICAL HANDRAIL EXTENSION7
ADUL
T
SOAP DISPENSER, W/SOAP CONTAINER,RECESSED
GRAB BARS
2' - 9
"
TO O
PERA
BLE
PART
6" TOE CLEARANCE
0' - 8"
27" M
IN
29" M
IN
34" M
AX
LAVATORY
TOILET TISSUE DISPENSER,SEMI-RECESSED, 3" MAX. F.O.WALL
HOT WATER SUPPLYAND WASTE PIPEINSULATED AT ALLLAVS.
PAPERTOWELDISPENSER
TOILETTISSUEDISPENSER
TOILET SEAT COVERDISPENSER, SANITARYNAPKIN DISPOSAL,TOILET TISSUEDISPENSER, RECESSED
ALARM
THERMOSTATSLIGHT SWITCHESPULL STATIONS
OUTLETS
1' -
3"
4' -
0" M
AX.
6' -
8"
FE
CO
NTR
OL
/ HA
ND
LE
48" M
AX.
TO E
XTIN
GU
ISH
ER
MISCELLANEOUS (THERMOSTATS, LIGHT SWITCHES, OUTLETS, MANUALPULL STATIONS, VISUAL/AUDIBLE ALARMS)
GRAB BARS ATACCESSIBLE TOILET
TOILET TISSUEDISPENSER, SEMI-RECESSED
GRAB BAR PLAN LAYOUT54
" MIN
17"- 18"
CL
1' - 6"
2' -
0"
3' -
4" M
AX.
7"-9
"
48" MIN. SST GRAB BAR.SEE A10.01 FOR MOUNTING.
SEMI-RECESSED TOILETTISSUE DISPENSER (3" MAX.FROM F.O. WALL)
36" MIN. SS GRAB BAR.
MIRROR,SURFACEMOUNTED
BOTTOM OFMIRRORED SURFACE
9" M
AX
TO P
APER
TO
WEL
S
40" M
AX
TO O
PER
ABLE
PAR
T
40" M
AX
TOILET SEATCOVER DISPENSER
7"-9"
19" M
IN
1' -
7"
24" M
IN- V
IF
12"
CL
5' - 0" CLR
CL
12" M
AX
17" -
19"
25" MAX17" MIN
ABC
DEFG
FLUSH HANDLE ON WIDESIDE
1-1/2" CLEAR SPACE AROUND GRAB BAR
14" M
IN
ADUL
T
CHILD
REN
AGE
3-4
FLUSH CONTROLS SHALL NOTREQUIRE TIGHT GRASPING,PINCHING, OR TWISTING OF THEWRIST. AND SHALL ACTIVATE WITH5 POUNDS FORCE MAX
FAUCET- OPERABLEWITHOUT TIGHT GRASPING,PINCHING, OR TURNING OFWRIST
1 1/2"
MIN
CLR
12" MAX 42" MIN
54" MIN
24" MIN
ACCESSIBLE WALL - MOUNT TOILET
T.O
. SEA
T
1' -
7"
ACCESSIBLE FLOOR MOUNT TOILET
T.O.
SEA
T
1' - 7
"
48" MIN
19" MAX
30" M
IN
17" MIN
18" M
INCLEARFLOORSPACE
CLEAR FLOOR SPACE AT LAVATORIES
HJ
0' -
0 1/
2"0'
- 1"
0' -
1"
0' -
0 1/
2"
PROVIDE SYMBOL AT ACCESSIBLERESTROOMS,NO SYMBOL AT NON-ACCESSIBLERESTROOMS
PROVIDE SCREW HOLES
PROVIDE SYMBOL AT ACCESSIBLERESTROOMS, NO SYMBOL AT NON-
ACCESSIBLE RESTROOMS
0' -
6"
1' -
0"
RAISEDTRIANGLE
SIGN FACE
DOOR
INTERNATIONAL SYMBOLOF ACCESSIBILITY (ISA-*) EXIT SIGN
TYPICAL FEMALE RESTROOM SIGN - FRONT VIEW
TYPICAL MALE RESTROOM SIGN - FRONT VIEW
TYPICAL UNISEX RESTROOM SIGN - FRONT AND SIDE VIEW
1 2
6" M
IN.
0' -
1"
0' -
0 1/
2"
0' -
0 1/
2"
0' -
6"
SIGN ON DOOR
0' -
0 1/
2"
1 20' -
0 1/
4"
SIGN ON DOOR
1' - 0
"
0' - 1
"0'
- 4"
0' - 0
1/2"
0' - 0
1/4"
TYPICAL ROOM NAME SIGN
STUDENT LEARNING CENTER
0' -
0 5/
8"
0' -
0 3/
8"EXIT RAMP DOWN
1' - 3"
0' - 5
"
0' - 0
3/8"
0' - 1
"
EXIT ROUTE SIGN
TYPE 1A
TYPE 1B
TYPE 1C
TYPE 1D TYPE 1E TYPE 1F TYPE 1G
GENERAL NOTES:
1. ALL SYMBOLS AND LETTERS TO BE RAISED MIN. 1/32" (0.794 mm) ABOVE SIGN/PLAQUE SURFACE TYP., TEXT TO BESANS-SERIF-UPPERCASE ACCOMPANIED BY CALIFORNIA CONTRACTED GRADE 2 BRAILLE.
2. ALL SYMBOLS AND LETTERS TO HAVE A COLOR WHICH CONTRASTS WITH SIGN BACKGROUND COLOR THAT MUST BE70% MINIMUM AND HAVE A NON-GLARE FINISH.
3. ALL SIGNS TO HAVE A COLOR WHICH CONTRASTS WITH DOOR COLOR.
4. ALL PLAQUES TO HAVE A COLOR WHICH CONTRASTS WITH WALL ADJACENT TO LATCH SIDE OF DOOR.
5. REFER TO DETAIL TYPICAL SIGNAGE LOCATION THIS SHEET FOR SIGN/PLAQUE LOCATION INFO.
6. WHERE GLAZING OCCURS ADJACENT TO DOOR, ATTACH PLAQUE WITH ADHESIVE TO GLAZING.
7. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE A MINIMUM OF 5/8 INCH(15.9 mm) AND A MAXIMUM OF 2 INCHES (51 mm) HIGH BASED ON THE HEIGHT OF THE UPPERCASE LETTER "T".
8. CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO AND A STROKE WIDTH-TO-HEIGHT RATIO PER 11B -703.2.6
9. CONTRACTED CALIFORNIA GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER PORTIONS OFTHESE STANDARDS. DOTS SHALL BE 1/10 INCH (2.54 mm) ON CENTERS IN EACH CELL WITH 3/10 INCH (7.6 mm) SPACEBETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH (0.635 mm) AND MAXIMUM OF .037 INCH (.9 mm) ABOVETHE BACKGROUND. THE DISTANCE BETWEEN CORRESPONDING DOTS FROM ONE CELL DIRECTLY BELOW SHALL BE AMINIMUM OF .395 INCH (10 mm) AND MAXIMUM OF .4 INCH (10.2 mm) PER TABLE 11B - 703.3.1
ROUNDED OR DOMED CALIFORNIA BRAILLE DOTS, EACH DISTINCT AND SEPARATE. DOTS WITH STRAIGHT SIDES AND FLATTOPS ARE NOT READABLE FOR MANY BRAILLE USERS.
10. BRAILLE SHALL BE POSITIONED BELOW CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT, OR CENTERED. IFTEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT.
11. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH
12. NO RAISED CHARACTERS SHALL BE ALLOWED ON GEOMETRIC TOILET SIGNS
13. ALL SIGNAGE WILL BE REVIEWED AND APPROVED BY THE LIGHTHOUSE FOR THE BLIND.
14. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHRACTERS WITHIN A MESSAGE SHALL BE 135PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER HEIGHT.
0' - 0 1/4"0' - 0 1/4" NOTES:1. FOR SIGN COLOR, USE BLUE COLOR NO. 15090(FEDRAL REGISTER STD. 595 B)
2. USE RAISED TRIANGLE ON RAISED CIRCLE
3. USE CONTRASTING COLOR FOR RAISED TRIANGLE
4. SIGN FACE SHALL BE 70%CONTRASTING COLOR BETWEENSIGN FACE AND DOOR
TYPICAL SIGN - SIDE VIEW
RAISEDTRIANGLE
SIGN FACE
DOOR
0' - 9 1/4"
0' -
7 1/
4"
1. SIGN SHALL BECONSTRUCTED OF 0.08"ALUMINUM.
2. LETTERING SYMBOL ANDBORDER SHALL BEREFLECTORIZED WHITEON A BLUE BACKGROUND.
3. LETTERING SHALL BE 1 INCH.
NO SMOKINGWITHIN 25 FTOF BUILDING
NO SMOKING SIGN
TYPE 1i
0' - 8"0'
- 8"
1.WHITE FIGURES AND LETTERS ONA BLUE BACKGROUND2. DIRECTIONAL ARROW VERIFYDIRECTION WITH ARCHITECT
TYPE 1H
ACCESSIBLE ENTRY SIGN
Consultants
Architect
Key Plan
Architect
A R C H I T E C T S165 Tenth Street Suite 100
San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103www. gelfand-partners.comG
Gelfand Partners
P
All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
Project
Drawing Record
Sheet
F
REN. 5-31-18NO. C17265
LISA JAYN
AT
OE
E
ST
LCI
ESD
IT
NAI
TC
R
IAC LOF
E
CA R H
GELFAND
Tennebaum-Manheim Engineers414 Mason Street, Suite 605San Francisco, CA 94102Tel (415) 772.9891 Fax (415) 772.9893
STRUCTURAL:
EDesignC Incorporated582 Market Street, Suite 400San Francisco, CA 94104Tel (415) 963.4303 Fax (415) 963.4341
MECHANICAL/ PLUMBING/ ELECTRICAL/ FIRE ALARM:
Issue/Submission Date
C:\Revit Projects\1431.01_1245 Alabama-2ndFloor_CENTRAL_karen.rvt5/3
0/201
7 12:1
2:46 P
M A10.01
TYPICAL SIGNAGE &ACCESSIBILITY DETAILS
1245 ALABAMA FAMILYRESOURCE CENTER
#1431
1245 ALABAMA ST, SANFRANCISCO CA
1/2" = 1'-0"FIXTURE AND ACCESSORY MOUNTING HEIGHTS- TYP U.O.N.1 3" = 1'-0"
TYPICAL SIGNAGE2