![Page 1: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/1.jpg)
OVERVIEW OF NYCT FACILITIES
• Locations Affected
• Site Details
• Site Pictures
• System Descriptions
• Impact Considerations
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 2: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/2.jpg)
NYCT FACILITIES: LOCATIONS AFFECTED
DOT BQE Map with NYCT Facilities
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 3: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/3.jpg)
NYCT FACILITIES: SITE DETAILS
Fan Plants
1. Furman Street at Cranberry, #6332 – Two (2) 250 HP Fans
2. Furman Street at Clark, #7230 – Four (4) 250 HP Fans (Missing on Proposal)
3. Furman Street at Montague, #5105 – Eight (8) 75 HP Fans
Traction Power Substations
1. Pierrepoint-Furman Street Substation, supplies 2,3 Train – Two (2) 3 MW units
2. Montague-Furman Street Substation, supplies R Train – Two (2) 3 MW units
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 4: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/4.jpg)
NYCT FACILITIES: SITE PICTURES
Furman Street at Cranberry, #6332
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 5: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/5.jpg)
NYCT FACILITIES: SITE PICTURES
Furman Street at Clark, #7230 (Missing on Proposal)
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 6: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/6.jpg)
NYCT FACILITIES: SITE PICTURES
Furman Street at Montague, #5105
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 7: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/7.jpg)
NYCT FACILITIES: SITE PICTURES
Pierrepoint-Furman Street Substation, supplies 2,3 Train
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 8: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/8.jpg)
NYCT FACILITIES: SITE PICTURES
Montague-Furman Street Substation, supplies R Train
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 9: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/9.jpg)
NYCT FACILITIES:SYSTEM DESCRIPTION - FAN PLANTS
Blows Fresh Air, Exhausts Smoke During a Fire Condition
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 10: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/10.jpg)
NYCT FACILITIES:SYSTEM DESCRIPTION - SUBSTATIONS
Supplies Power to the 3rd Rail for Trains
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 11: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/11.jpg)
NYCT FACILITIES:IMPACT CONSIDERATIONS
• System Effects
• Underground Fan Plant – Missing on Proposal
• New Facility Cost, Duration
• Recent Facility Expenses
• Environmental
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 12: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/12.jpg)
• Fan Plants (FP)
• FP location dictates fan sizes Relocating requires CFD analysis
• All FPs have emergency exit shafts from tunnel to street Must be accessible
• Traction Power Substations (TPSS)
• Recent Studies have called for system improvements No redundancy in area
NYCT FACILITIES:IMPACT CONSIDERATIONS: SYSTEM EFFECTS
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 13: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/13.jpg)
Furman Street at Clark, #7230 – Effects on this FP must be discussed
NYCT Tunnel
2 , 3 Train
NYCT Fan
Plant #7230
Flow of Air
NYCT FACILITIES:IMPACT CONSIDERATIONS: UNDERGROUND FAN PLANT
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 14: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/14.jpg)
Recent Expenses
Fan Plant Flood Proofing:
2015 to 2020 ~$2.8M / FP
* New facility cost and duration includes design and construction
NYCT FACILITIES:IMPACT CONSIDERATIONS: NEW FACILITY COST, DURATION
0
10
20
30
40
50
60
70
Fan Plant Substation
$70M
$50M
Average New Facility Cost ($M)
6 yrs
5 yrs
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents
![Page 15: OVERVIEW OF NYCT FACILITIES…2019/04/18 · NYCT FACILITIES: SITE DETAILS Fan Plants 1. Furman Street at Cranberry, #6332 –Two (2) 250 HP Fans 2. Furman Street at Clark, #7230](https://reader036.vdocuments.us/reader036/viewer/2022070110/604b39c3d7de786a8c42096b/html5/thumbnails/15.jpg)
• Require an Analysis of Reconstruction or Site Relocation
• Develop Documentation:
• Environmental Due Diligence Assessment (EDDA)
• SEQR Environmental Assessment
• Environmental Impact Statement (EIS)
• Construction Environmental Protection Plan (CEPP)
NYCT FACILITIES:IMPACT CONSIDERATIONS: ENVIRONMENTAL
As presented to the BQE Expert Panel for informational/background purposes only. https://bqe-i278.com/en/expert-panel/documents