Transcript
Page 1: OLLER R AL U TION MAN , KJR-120F3/BMK-E. KJR-120F1/BMK-E … · 2015-09-01 · Screw hole fixed on the wall,use one GB950-86 M4X20 Screw hole installed on 86 Electrician box, use

6. F

ront

cov

er in

stal

latio

n

Cut

ting

plac

e of

left

do

wn

side

wire

out

let

44mm

60m

m

Buc

klin

g

posi

tion

Bac

k co

ver

Stra

ight

hea

d

scre

wdr

iver

Fron

t cov

er

Fig.

4.1

Fig.

4.2

Fi

g.4.

3

86

Ele

ctric

ian

bo

x

Bac

k co

ver

Sig

nal s

witc

hing

w

ires

Fig.

4.4

Left

dow

n si

de w

ire

outle

t

Fig.

5.2

Fig.

5.1

Fig.

6.2

Fig.

6.1

(b) E

mbe

dded

86

elec

trici

an

b

ox w

iring

A

.Wiri

ng, t

hree

out

letti

ng p

ositi

ons

C.S

hiel

ded

wiri

ng

Wiri

ng

hole

86 Electrician box

Dia

met

er:

Φ8-

-Φ10

W

all h

ole

and

wiri

ng h

ole

Put

ty

Trap

P

utty

Trap

Put

ty

Trap

4. B

ack

cove

r ins

talla

tion

5. W

iring

1) U

se s

traig

ht h

ead

scre

wdr

iver

to in

sert

into

the

buck

ling

posi

tion

in th

e bo

ttom

of w

ire

cont

rolle

r, an

d sp

in th

e sc

rew

driv

er to

take

dow

n th

e ba

ck c

over

. (P

ay a

ttent

ion

to s

pinn

ing

dire

ctio

n, o

ther

wis

e w

ill d

amag

e th

e ba

ck c

over

!) (F

ig.4

.1)

2) U

se th

ree

GB

950-

86 M

4X20

scr

ews

to d

irect

ly in

stal

l the

bac

k co

ver o

n th

e w

all.

(Fig

.4.2

) 3)

Use

two

M4X

25 G

B82

3-88

scre

ws

to in

stal

l the

bac

k co

ver o

n th

e 86

ele

ctric

ian

box,

and

use

on

e G

B95

0-86

M4X

20 s

crew

s fo

r fix

ing

on th

e w

all.

(Fig

.4.3

)

Whe

n un

der i

nsta

llatio

n,

rese

rve

certa

in le

ngth

of

the

conn

ectin

g w

ire fo

r co

nven

ient

to ta

ke d

own

the

wire

d re

mot

e co

ntro

ller w

hile

dur

ing

mai

nten

ance

.

Avoi

d th

e w

ater

ent

er in

to t

he

wire

d re

mot

e co

ntro

ller,

use

trap

and

putty

to

se

al

the

conn

ecto

rs

of

wire

s du

ring

wiri

ng in

stal

latio

n. (F

ig.5

.2)

Afte

r adj

ustin

g th

e fro

nt c

over

and

then

buc

kle

the

front

cov

er; a

void

cl

ampi

ng th

e co

mm

unic

atio

n sw

itchi

ng w

ire d

urin

g in

stal

latio

n. (F

ig.6

.1)

4) A

djus

t the

leng

th o

f tw

o pl

astic

scr

ew b

ars

in th

e ac

cess

ory

to b

e st

anda

rd le

ngth

from

the

elec

tri-

cal b

ox s

crew

bar

to th

e w

all.

Mak

e su

re w

hen

inst

all t

he s

crew

bar

to th

e el

ectri

cal b

ox s

crew

bar

, m

ake

it as

flat

as

the

wal

l. (F

ig.4

.4)

5) U

se c

ross

hea

d sc

rew

s to

fix

the

wire

con

trolle

r bot

tom

cov

er in

the

elec

tric

cont

rol b

ox th

roug

h th

e sc

rew

bar

. Mak

e su

re th

e w

ire c

ontro

ller b

otto

m c

over

is o

n th

e sa

me

leve

l afte

r ins

talla

tion,

an

d th

en in

stal

l the

wire

con

trolle

r bac

k to

the

botto

m c

over

. 6)

Ove

r fas

ten

the

scre

w w

ill le

ad to

def

orm

atio

n of

bac

k co

ver.

Scr

ew h

ole

inst

alle

d on

the

wal

l,use

th

ree

GB95

0-86

M4X

20

Scr

ew h

ole

inst

alle

d on

86

Ele

ctric

ian

box,

use

two

M4X

25 G

B82

3-88

Scr

ew h

ole

fixed

on

the

wal

l,use

on

e G

B95

0-86

M4X

20

Cor

rect

inst

all t

he b

ack

cove

r and

firm

ly b

uckl

e th

e fro

nt c

over

and

bac

k co

ver,

othe

rwis

e w

ill m

ake

the

front

cov

er d

rop

off.

(Fig

.6.2

)

Tha

nk y

ou v

ery

muc

h fo

r pur

chas

ing

our p

rodu

ct.

Bef

ore

usin

g yo

ur u

nit,

plea

se re

ad th

is m

anua

l car

eful

ly a

nd k

eep

it fo

r fut

ure

refe

renc

e.

WIR

ED

RE

MO

TE

CO

NT

RO

LLE

RIN

STA

LLA

TIO

N M

AN

UA

L

SAFE

TY P

REC

AU

TIO

N

Rea

d th

e sa

fety

pre

caut

ions

car

eful

ly b

efor

e in

stal

ling

the

unit.

S

tate

d be

low

are

impo

rtant

saf

ety

issu

es th

at m

ust b

e ob

eyed

. C

onfo

rm th

ere

is n

o ab

norm

al p

heno

men

a du

ring

test

ope

ratio

n af

ter c

ompl

ete,

then

ha

nd t

he m

anua

l to

the

user

. M

eani

ng o

f mar

ks:

W

AR

NIN

G

CA

UTI

ON

Mea

ns im

prop

er h

andl

ing

may

lead

to p

erso

nal d

eath

or

seve

re in

jury

.

Mea

ns im

prop

er h

andl

ing

may

lead

to p

erso

nal i

njur

y or

pr

oper

ty lo

ss.

OTH

ER P

REC

AU

TIO

NS

WA

RN

ING

CA

UTI

ON

Plea

se e

ntru

st th

e di

strib

utor

or p

rofe

ssio

nals

to in

stal

l the

uni

t. In

stal

latio

n by

oth

er p

erso

ns m

ay le

ad to

impe

rfect

inst

alla

tion,

ele

ctric

sho

ck o

r fire

. St

rictly

follo

w th

is m

anua

l. Im

porp

er in

stal

latio

n m

ay le

ad to

ele

ctric

sho

ck o

r fire

. R

eins

talla

tion

mus

t be

perf

orm

ed b

y pr

ofes

sion

als.

im

prop

er in

stal

latio

n m

ay le

ad to

ele

ctric

sho

ck o

r fire

. D

o no

t dis

asse

mbl

e yo

ur a

ir co

nditi

oner

at w

ill.

A

rand

om d

isas

sem

bly

may

cau

se a

bnor

mal

ope

ratio

n or

hea

ting,

whi

ch m

ay re

sult

in fi

re.

Do

not i

nsta

ll th

e un

it in

a p

lace

vul

nera

ble

to le

akag

e of

flam

mab

le g

ases

. O

nce

flam

mab

le g

ases

are

leak

ed a

nd le

ft ar

ound

the

wire

con

trolle

r, fir

e m

ay o

ccur

e.

The

wiri

ng s

houl

d ad

apt t

o th

e w

ire c

ontr

olle

r cur

rent

. O

ther

wis

e, e

lect

ric le

akag

e or

hea

ting

may

occ

ur a

nd re

sult

in fi

re.

The

spec

ified

cab

les

shal

l be

appl

ied

in th

e w

iring

. No

exte

rnal

forc

e m

aybe

app

lied

to th

e te

rmin

al.

Oth

erw

ise,

wire

cut

and

hea

ting

may

occ

ur a

nd re

sult

in fi

re.

Do

not p

lace

the

wire

d re

mot

e co

ntro

ller n

ear t

he la

mps

, to

avoi

d th

e re

mot

e si

gnal

of t

he c

ontr

olle

r to

be d

istu

rbed

. (re

fer t

o th

e rig

ht fi

gure

)

1 2 3 4 5

1 3 2 1 1

GB

950-

86 M

4X20

(Fo

r Mou

ntin

g on

the

Wal

l)

M4X

25 G

B82

3-88

(F

or M

ount

ing

on th

e E

lect

rical

Sw

itch

Box

)

1 2 3

1 1 1

RV

VP

-0.5

mm

2 x3

6 73 2

81

1. In

stal

latio

n Lo

catio

n

Do

not i

nsta

ll th

e un

it in

a p

lace

with

muc

h oi

l, st

eam

, sul

fide

gas.

Oth

erw

ise,

the

pr

oduc

t may

def

orm

and

fail.

2.

Pre

para

tion

befo

re in

stal

latio

n

1) C

heck

whe

ther

the

follo

win

g as

sem

blie

s ar

e co

mpl

ete.

No.

N

ame

Qty

. R

emar

ks

Wire

con

trolle

r

Inst

alla

tion

Man

ual

Ow

ner's

Man

ual

For M

ount

ing

on th

e W

all

2) P

repa

re th

e fo

llow

ing

asse

mbl

ies

on th

e si

te.

3-co

re s

hiel

ded

cabl

e

Ele

ctric

ian

box

Wiri

ng T

ube(

Insu

latin

g S

leev

e an

d Ti

ghte

ning

S

crew

)

Qty

.(em

bede

d

into

wal

l)

3. N

ote

to in

stal

latio

n of

wir

e co

ntro

ller:

1) T

his

inst

alla

tion

man

ual c

onta

ins

info

rmat

ion

abou

t th

e pr

oced

ure

of in

stal

ling

Wire

d R

emot

e C

ontro

ller.

Ple

ase

refe

r to

Ind

oor

Uni

t In

stal

latio

n M

anua

l fo

r co

nnec

ting

betw

een

Wire

d R

emot

e C

ontro

ller a

nd In

door

Uni

t. 2)

Circ

uit o

f Wire

d R

emot

e C

ontro

ller i

s lo

w v

olta

ge c

ircui

t. N

ever

con

nect

it w

ith a

sta

ndar

d 22

0V/3

80V

circ

uit

or p

ut it

into

a s

ame

Wiri

ng T

ube

with

the

circ

uit.

3) T

he s

hiel

d ca

ble

mus

t be

conn

ecte

d st

able

to th

e gr

ound

, or t

rans

mis

sion

may

fail.

4)

Do

not

atte

mpt

to

exte

nd t

he s

hiel

d ca

ble

by c

uttin

g, if

it is

nec

essa

ry,

use

Term

inal

C

onne

ctio

n B

lock

to c

onne

ct.

5) A

fter f

inis

hing

con

nect

ion,

do

not u

se M

egge

r to

have

the

insu

latio

n ch

eck

to th

e si

gnal

w

ire. P

last

ic s

crew

bar

Cro

ss ro

und

head

woo

d

mou

ntin

g sc

rew

C

ross

roun

d he

ad

mou

ntin

g sc

rew

Pla

stic

exp

ansi

on p

ipe

For f

ixin

g on

the

86 e

lect

ricia

n bo

x

No.

N

ame

Rem

arks

S

peci

ficat

ion

(onl

y fo

r ref

eren

ce)

EPA B

19mm 84mm

44mm

46m

m

60m

m

P

Q A

B P

Q

E

P

Q

E

3-co

re s

hiel

ding

wire 3-co

re s

hiel

ding

wire

INST

ALL

ATIO

N P

RO

CED

UR

E A

ND

MAT

CH

ING

SET

TIN

G O

F W

IRE

CO

NTR

OLL

ER

QEP Q

E A

C22O

V

rellortnoC eri

W

Scr

ew

Fron

t cov

er

Con

trol p

anel

1. W

ired

rem

ote

cont

rolle

r str

uctu

re s

ize

figur

e2.

Wiri

ng s

ketc

h:

3. W

iring

figu

re

mm02

mm021

120mm

Figu

re A

Ada

pter

Fo

r sup

plyi

ng p

ower

for w

ire c

ontro

ller

For c

onne

ctin

g w

ire c

ontro

ller

and

mai

n un

it

Ada

pter

: IN

PU

T

AC

220V

OU

TPU

T

AC

10V

Out

door

Uni

tel

ectri

c co

ntro

l box

Ple

ase

purc

hase

the

3-C

ore

Shi

eld

Cab

le o

f 0.5

mm

2 x3

dur

ing

inst

alla

tion.

1) D

urin

g in

stal

latio

n, m

ake

sure

cor

rect

ly w

iring

the

5

wiri

ng te

rmin

als

of th

e w

ire c

ontro

ller:

A, B

con

nect

to

outp

ut te

rmin

al o

f ada

pter

; P, Q

, E s

houl

d co

nnec

t to

the

P, Q

, E te

rmin

als

of th

e w

iring

soc

ket i

n th

e el

ectri

c co

ntro

l box

thro

ugh

3-co

re s

hiel

ded

wire

. 2)

The

tigh

teni

ng to

rque

rang

e of

scr

ew is

:0.8

~1.2

N •

m

(8~1

2 kg

f • c

m).

Wiri

ng s

ocke

t in

the

mai

n un

it el

ectri

c co

ntro

l boxB

lack

Blu

e

Whi

te

EP QB

lack

Blu

e

Whi

te

MAN-I-WRC

MCH

-061

5

MO

DE

L: K

JR-1

20F/

BM

K-E,K

JR-1

20F1

/BM

K-E

KJR

-120

F2/B

MK

-EK

JR-1

20F3

/BM

K-E

. ,,

Top Related