Download - Objectives of shunt compensation
![Page 1: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/1.jpg)
1
STATIC SHUNT COMPENSATION
Presented by
T.S.L.V.Ayyarao
![Page 2: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/2.jpg)
2
OBJECTIVES OF SHUNT COMPENSATION
Steady-state transmittable power can be increased. Voltage profile can be controlled. Shunt connected reactors (fixed or mechanically
switched) are applied to minimize line over voltage under light load conditions.
Shunt connected capacitors are applied to maintain voltage levels under heavy load conditions.
![Page 3: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/3.jpg)
3
MIDPOINT REGULATION FOR LINE SEGMENTATION
Consider two bus transmission model with ideal var compensator at the midpoint.
The compensator divides line into 2 parts.
![Page 4: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/4.jpg)
4
MIDPOINT REGULATION FOR LINE SEGMENTATION
Midpoint var compensator exchange only reactive power with the line.
Real power is same at each terminal
![Page 5: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/5.jpg)
5
MIDPOINT REGULATION FOR LINE SEGMENTATION
The transmitted power is
The relation between P, Q and angle
![Page 6: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/6.jpg)
6
MIDPOINT REGULATION FOR LINE SEGMENTATION
Midpoint shunt compensation significantly increase the transmittable power.
Mid point of the transmission line is the best location for the compensator.
Voltage sag is maximum at the mid point.
![Page 7: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/7.jpg)
7
END OF LINE VOLTAGE SUPPORT TO PREVENT VOLTAGE INSTABILITY
Consider a radial Transmission line
![Page 8: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/8.jpg)
8
END OF LINE VOLTAGE SUPPORT TO PREVENT VOLTAGE INSTABILITY
![Page 9: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/9.jpg)
9
END OF LINE VOLTAGE SUPPORT TO PREVENT VOLTAGE INSTABILITY
Reactive shunt compensation can effectively increase the voltage stability limit and regulates the terminal voltage.
End of the line is the best location for compensator.
![Page 10: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/10.jpg)
10
IMPROVEMENT OF TRANSIENT STABILITY
![Page 11: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/11.jpg)
11
IMPROVEMENT OF TRANSIENT STABILITY
![Page 12: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/12.jpg)
12
IMPROVEMENT OF TRANSIENT STABILITY
![Page 13: Objectives of shunt compensation](https://reader031.vdocuments.us/reader031/viewer/2022012306/54be28b04a7959ee018b459f/html5/thumbnails/13.jpg)
13
POWER OSCILLATION DAMPING