![Page 1: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/1.jpg)
New Methods for Testing and Extraction of Soluble Salts Presented by: Dr. Lisa D. Detter-Hoskin, Principal Research Scientist Georgia Tech Research Institute
![Page 2: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/2.jpg)
Introduction• This webinar will describe the most
commonly used field methods for the retrieval and analysis of soluble salts on steel and other nonporous substrates.
![Page 3: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/3.jpg)
SSPC Guide 15• A guide that describes the most
commonly used field methods for extraction and analysis of soluble salts
• Recently revised– Expected to be published in July 2013
![Page 4: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/4.jpg)
Field Methods for Measuring Soluble Salts by Conductivity• Fully Automated Conductivity Measurement
– Soluble Salt Meter– Surface Salinity Meter– Continuous Flow Extraction Fiber Strip
• Multi-Step Conductivity Measurement – Surface Swab or Wash/Probe Type Conductivity
Meter Technique– Adhesively Bonded Latex Patch or Cell/Probe Type
Conductivity Meter Technique– Saturated Special Filter Paper/Concentric Ring
Conductivity Meter Technique
![Page 5: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/5.jpg)
Fully Automated Conductivity Measurement
• Direct real-time automated systems• Measures solution salinity from
conductance• Hand-held and portable• Self calibrating and paperless
![Page 6: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/6.jpg)
Soluble Salt Meter
![Page 7: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/7.jpg)
Continuous Flow Extraction Fiber Strip
![Page 8: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/8.jpg)
Advantages• Some sensors will attach magnetically to some metals• Methods are real time• All critical steps are automated and pre-measured• Reduced setup• Testing can be performed on vertical, horizontal and
overhead surfaces• Methods are paperless; digital output• Reduction in consumables and no hazardous materials
required• Readings may be recorded• Sensor test area is standardized and cannot be
manipulated
![Page 9: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/9.jpg)
Limitations• Meters may not conform to curved and
irregular surfaces• Sensors will not adhere to a surface that
is not magnetic• Measures conductivity of total soluble
salts rather than a specific ion• Fully automated conductivity
measurement techniques must be purchased as systems and are not interchangeable
![Page 10: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/10.jpg)
Surface Swab or Wash/Probe Type Conductivity Meter Technique
![Page 11: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/11.jpg)
Advantages• The swabbing retrieval method provides a
means for acquiring samples of salt from steel or other non-porous surfaces using readily available materials
• Retrievals can be conducted on a range of surfaces without regard to surface irregularities or condition
• The swabbing method can be used on large areas to indicate general surface contamination by salts
• The extractions also provide sufficient sample size for several analyses to be performed for different ions
![Page 12: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/12.jpg)
Limitations• Swabbing methods are difficult to
perform in an overhead or vertical position
• Swabbing is not well suited for measuring salt levels of small, localized contamination such as craters or pits
• There is a risk of contamination of a sample by the operator if gloves or any other equipment used for these procedures become damaged
![Page 13: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/13.jpg)
Adhesively Bonded Latex Patch or Cell/Probe-Type Conductivity Meter Technique
![Page 14: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/14.jpg)
Adhesively Bonded Latex Patch or Cell/Probe-Type Conductivity Meter Technique
![Page 15: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/15.jpg)
Advantages• Cells can conform to curved and irregular
surfaces• Cells such as these are commercially
available in a variety of sizes• If reagent water has been used as the
extraction liquid, conductivity can be determined using commercially available conductivity meters
![Page 16: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/16.jpg)
Limitations• The adhesively attached cells only
accommodate a small amount of extraction liquid
• No in-line determination of conductivity can be performed with these cells
![Page 17: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/17.jpg)
Limitations• The cell may not adhere well to heavily
rusted surfaces, but it may adhere to abrasive blast cleaned surfaces so well as to cause difficulty in removing the patch
• The cell may leak through the hole introduced by the syringe
• The cells are consumable and can be used only once
• The patch cell will add background conductivity
![Page 18: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/18.jpg)
Limitations• Dilution of extraction liquid introduces
greater error in final result• No standard procedure for the intensity of
rubbing, thus making the result subject to operator
• Flexible patches can be stretched to 10% more than their original intended footprint influencing the final result
• When acidic extraction solutions are used, patch cell is not suitable for conductivity measurement
![Page 19: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/19.jpg)
Advantages• Suitable for a wide range of shapes,
orientations, surface and finishes• Battery operated and portable
![Page 20: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/20.jpg)
Limitations• No in-line determination of
conductivity can be performed with this unit
• Water may be lost from the filter paper introducing error
• The filter paper is a consumable and can be used only to extract salts
• Background correction for the blank filter paper must be manually performed
![Page 21: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/21.jpg)
Field Methods Measuring Specific Ions• Chloride Ion paper Strip Test of Swab/Wash or
Latex Patch/Cell Extracts• Chloride Ion Detection Tube Test of
Swab/Wash or Latex Patch/Cell Extracts• Ferrous Ion Paper Strip Test of Swab/Wash or
Latex Patch/Cell Extracts• Field Drop Titration for Chloride of
Swab/Wash or Latex Patch/Cell Extracts• Latex Sleeve Methodology• Field Detection Sulfate Ion by Visual Turbidity• Qualitative Field Detection of Ferrous Ions
![Page 22: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/22.jpg)
Chloride Ion Paper Strip Test of Swab/Wash or Latex Patch/Cell Extracts
• Chloride ion paper test strips are utilized to determine chloride ion concentrations of swab- or patch cell-extracted solutions
![Page 23: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/23.jpg)
Chloride Ion Paper Strip Test of Swab/Wash or Latex Patch/Cell Extracts
![Page 24: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/24.jpg)
Chloride Ion Detection Tube Test of Swab/Wash or Latex Patch/Cell Extracts
• Sealed vacuum tubes are utilized to determine chloride ion concentrations of swab- or patch cell-extracted solutions
![Page 25: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/25.jpg)
Ferrous Ion Paper Strip Test or Swab/Wash or Latex Patch/Cell Extracts• Ferrous ion paper test strips are
utilized to determine ferrous ion concentrations of swab- or patch cell-extracted solutions
![Page 26: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/26.jpg)
Field Drop Titration for Chloride of Swab/Wash or Latex Patch/Cell Extracts
• Test kit is used to analyze the solution collected from the surface using swab or patch cell extraction methods
![Page 27: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/27.jpg)
Field Drop Titration for Chloride of Swab/Wash or Latex Patch/Cell Extracts
![Page 28: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/28.jpg)
Field Drop Titration for Chloride of Swab/Wash or Latex Patch/Cell Extracts
• The chart below is used to determine the concentration of chloride ion in the sample
No. of Drops From Bottle 4 Concentration of Chloride Ion
1 Less than 2μg/cm2
2 2-4μg/cm2
3 4-6μg/cm2
4 8-10μg/cm2
![Page 29: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/29.jpg)
Latex Sleeve Methodology• This method uses a small flexible
chloride-free latex sleeve with a self-contained adhesive edge. A proprietary solution is dosed into the sleeve, and the sleeve is attached to the structure being tested, forming a cavity. The solution is massaged against the surface being tested for a specified period of time and is then removed. The sleeve then is removed and extracted solution tested for levels of chlorides.
![Page 30: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/30.jpg)
Latex Sleeve Methodology
![Page 31: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/31.jpg)
Advantages• This method is very simple to
perform, as all components are pre-measured
• The adhesive sleeve can conform to curved and irregular surfaces. Tests can be performed on vertical, horizontal, and overhead surfaces
• For extremely rough or pitted surfaces, the seal ring may be doubled, thereby allowing testing to be performed
![Page 32: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/32.jpg)
Advantages• The kit form of this method provides a
pre-measured volume of extraction solution and a fixed area of the sleeve opening.
• All components are one-time usage, eliminating cross contamination from test to test
• In hot weather or on hot surfaces, the encapsulated extract solution will not evaporate
![Page 33: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/33.jpg)
Advantages• The extractions also provide
sufficient sample size for analyses to be performed for different ions
• Acidic extraction liquids normally provide improved extraction efficiency compared to reagent water
![Page 34: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/34.jpg)
Limitations• The adhesive sleeve may not adhere
well to rusted surfaces, but may adhere so well to clean or grit blasted surfaces that it is difficult to remove the adhesive sleeve from the surface
• No in-line conductivity can be performed with the sleeves
• The sleeves are consumable and can be used only once
![Page 35: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/35.jpg)
Field Detection Sulfate Ion by Visual Turbidity
• Works on the principle that if sulfate is present in the extracted salt solution, it becomes turbid (cloudy) when barium chloride is added
![Page 36: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/36.jpg)
Qualitative Field Detection of Ferrous Ions
• Blotting paper is treated with potassium ferricyanide solution. The blotting paper is moistened and placed in contact with the steel surface to be tested. On contact with ferrous ions, the paper shows blue spots
![Page 37: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/37.jpg)
Summary• This webinar described several ways
to test for soluble salts on a surface. The technique selected is based on whether you want to know both the quantity and the type of soluble salt that is on the surface or, whether you just want to know if soluble salts are present.
![Page 38: New Methods for Testing and Extraction of Soluble Salts](https://reader033.vdocuments.us/reader033/viewer/2022051001/56814c53550346895db96977/html5/thumbnails/38.jpg)
Questions?