ENERGY UNDER CONTROL
Tracking Energy
ENERTRAK
www.enertrak.in
Panel Meters
Demand Controllers
Multi Source Utility System
Timers
RTC Based Street Light Controllers
GSM/GPRS/RS485 Modems
Softwares
Manual & AMF DG Controllers
Engine Safety Unit
Protection Relays
Servo Controllers
Pump Controllers with SCADA
On Line Energy Management
Data Logger
Approved OEM to EICHER
-:Our Product Range:-
Nomenclature
Size
Rating
Display
Features
3 Phase Voltmeter
96X96
3X240V , CL 1.0
Single Line LED
Display For showing Voltage of Three Phase Voltage (L-N & L-L). Available in single phase also.
NomenclatureSizeRatingDisplayFeatures
Three Phase VIF,Run Hr.,RPM96X963X240V, 3X-/5A , Aux Supply 240V, CL 1.0Three Line LEDAny Combination of V,A,F &Run Hr. Field Programmable CT ratios in scrolling mode. Available in single phase also.
Nomenclature Three Phase Current Size 96X96Rating 3X-/5A , Aux Supply 240V, CL 1.0Display Single Line LEDFeatures
Nomenclature Three Phase VIF, PF, kW, kWh, KVA, KVAh, RPM,Run Hr.
Size 96X96Rating 3X240V, 3X-/5A , Aux Supply 240V, CL 1.0
Display Three Line LED
Features Any Combination of VIF, PF, kW, kWh, KVA, KVAh, RPM,Run Hr. Field Programmable CT ratios in scrolling mode .Available With Rs485 also.
Nomenclature Three Phase VIF, PF, kW, kWh, KVA, KVAh, KVAr, KVArh, RPM Run hr
Size 96X96
Rating 3X240V, 3X-/5A , Aux Supply 240V, CL 1.0
Display Three Line LED
Features Any Combination of VIF ,PF,kW,kWh,KVA,KVAH,KVAr,KVArh & RPM . Field Programmable CT ratios in scrolling mode. Available With RS 485 also.
Nomenclature Three Phase kWh (Single Source & Dual Source)
Size 96 X 96
Rating 240 V , -/5A,CL 1.0
Display Two Line LED
Features Kwh with field programmable CT ratio
TAFV0410
TAFI0410
TMF25
TMF28
TMF42
TEN34
Nomenclature Three Phase VIF, PF, kW, KVA, kWh,RPM,Run Hr.Size 96X96Rating 3X240V, 3X-/5A , Aux Supply 240V, CL 1.0Display 3 Line LEDFeatures Any Combination of V, A, F, PF, kW, KVA, kWh & Run Hr. Field
Programmable CT ratios in scrolling mode. Available in single phase also.
TMF15
Hold ScrollSetup
TAFV0810
YRB
V
Enertrak
K
TAFI0410
V
Enertrak
TMF25
Prog
Enertrak
V
A
Hz
B
Y
R
TMF28
Enertrak
W
A
PF
VA
VL-L
VL-N
Hz
K
K
K
B
Y
R
Cal
Wh VAh
Cap Ind
Prog
Page
TMF42
Enertrak
W
A
PF
VAr
VA
VL-L
VL-N
Hz
K
K
K
B
Y
R
M
M
M
Cal
THD Wh VAhVArhCap Ind
Prog
Page
CAL
Prog
Enertrak
TEN34
1600 Imp/kWh
kWh
0.11
10100
100010000
1000001000000
Display For showing of Current Three Phase (R,Y,B) with field programmable CT Ratio. Available in single phase also.
kW
A
PF
Cap IndB
Y
R
kVA
VL-L
VL-N
Hz
TMF15
Prog
Enertrak
Enertrak
www.enertrak.in
Digital Panel MetersVoltmeter/Ammeter/Multifunction Meter
Nomenclature 1 Phase Servo Controller
Size 96X96Rating 240 V , -/5A, CL 1.0
Display Dual Line LED
Features SCR based zero cross over control with field programmable voltage & current setting
Nomenclature 3 Phase Demand Controller
Size 96X96
Rating 240V, -/5A , Aux Supply 240V, CL 1.0
Display Three Line LED
Features Any Combination of V/I/F/KW/Pf/Kwh. Field Programmable CT ratio.Tripping on over Volt, Amp, Frequency, kW, kVA.
3 Phase Multi Source Utility System175X76X225 mm3 X 240V, 10-60A , 50Hz , CL 1.0Single Line LCDProgrammable thru “Tarang” software in house designed based on advancedmicroprocessor & RTC. It uses inbuilt Latching Relay thereby eliminatingthe requirement of expensive contractor
NomenclatureSizeRatingDisplayFeatures
Nomenclature Timer / Controller (1Phase/3Phase) Size 128X164X90 mmRating 240V, 50Hz, 10-60A, CL 1.0Display Single Line LCD Features
Nomenclature Data Logger Size 96X96Rating 3 X 240V,-/5A , Aux Supply 240V, Cl 1DisplayFeatures
Nomenclature Eb-DG Controller / Current Limiting Device (CLD) SizeRating 3X240V , 10-40 Amp., Display Single Line LCD Features Current Limiting device with switching of Electricity board supply to the
Diesel generator supply ,there by saving fuel of DG.
ESC-091
TMF42
EURO 3
TMF15
Timer / Controller
EBDGWC
Nomenclature Pump Controller & Data Acquisition System
Size 175X76X225 mmRating 3X240V, 10-60A, 50Hz, CL 1.0Display 1 Line LCD
Features Specially Design for high degree of precision in controlling action of water supply system under PWD with SCADA
Pump Controller
240V, 50Hz,
Class 1
Program
Timer / Controller
Electronic, 1-Phase, 2-WireScroll (UP)
Scroll(Down)
In Built Disconnector
Enertrak
Three Line LEDAny Combination of V/I/F/KW/Pf/Kwh. Field Programmable CT ratio. inbuilt Data Recording & Export by RS232 Commination with energy auditing software.
Field Programmable intelligent time operated devices based on advancedmicroprocessor & RTC. It uses inbuilt Latching Relay thereby eliminatingthe requirement of expensive contractor
96X96
kW
A
PF
Cap IndB
Y
R
kVA
VL-L
VL-N
Hz
TMF15
Prog
Enertrak
Controller / TimersPump Controller/Demand Controller/Prepaid Meter
Enertrak
www.enertrak.in
Nomenclature Engine Safety Unit
Size 96X96Rating 240 V, -/5A, Auxiliary Supply 8V to 36V
Display Single Line LED Display Features LED Indication and Alarm for various commonly occuring of DG. Additional
Prevention Circuitry for Fan Jamming.
Nomenclature DG Controller
Size 96X96Rating 3X240 V, -/5A, Auxiliary Supply 8V to 36V Display 16X2 LCD Display Features Universal DG Controller that can be used with almost all types of DG and
has programmable option for water / air cooling and 1&3 phase Selection.
Nomenclature AMF Controller Size 96X96Rating 3X240 V, -/5A, Auxiliary Supply 8V to 36V Display 16X2 LCD Display Features It can be used with most of the contemporary gensets. The programable
features ensure that a single product can match the majority of therequirement of the genset industry.
Nomenclature Engine Safety Unit
Size 96X96Rating 3X240 V, -/5A, Auxiliary Supply 8V to 36V Display No DisplayFeatures It has been designed to protect the DG Sets from various external &
internal faults. It ensures that the tripping of the various relay are doneprecisely as per the programmed requirements.
Nomenclature Voltage Protection Relay, Current Protection Relay.
Size 96X96
Rating 240V, -/5A , Aux Supply 240V, Cl 1.0
Display Single Line LED Display
Features It Provides triping action on user programmable higher and lower limits. It has potential free output for hooter and other relay. Also available in Current & Frequency Model.
Nomenclature Protection Relay Unit
Size 96X96
Rating 3X240 V, -/5A, Auxiliary Supply 8V to 36V
Display 16X2 LCD Display
Features It is an Universal Protection Relay unit for generator and other applicationsthe device can be programmed on site for 1 or 3 phase application
EESU-3300
EDGC-6600
EAMF-9900
EPRU-5500
EESU-2200
EVPR1010
FL100
70
60
50
40
30
20
10
½
LL
LLOP
HWT/HCT
Low Fuel
RWL/Fan F.
Emer.
Canopy Temp.
OS/US
Chg. Alt/V-BF
Low Bat
RPM
Run H
Stop Reset Accept Scroll
Prog.
Vdc
A/CoolW/Cool
PIU
+
EnertrakEESU-3300
Service Due
%
EnertrakEDGC-6600
Start Accept
Down Up
Prog.
LLOP
RWL/Fan F.
HWT/HCT
Low Fuel
OV/UV
OS/US
Chg. Alt/V-BF
OC
Emer./
Canopy Temp.
Service
Due
Low
Bat
Mains
Stop
Reset
EnertrakEAMF-9900
LLOP
RWL/Fan F.
HWT/HCT
Low Fuel
OV/UV
OS/US
Chg. Alt/V-BF
OC
DG ONMains ON
Prog.
Start Accept
Down Up
Stop
Reset
MCB
GCB
Load
ON DG
Load
ON Mains
EnertrakEPRU-5500
Down Up
Prog.SPP
Earth Fault
Reverse
Ph. Seq.
Current
Unbalance
Over / Under
Voltage
Timer
Over
Current
Reset
Over / Under
RPM
Protection Relay Unit
EnertrakEESU-2200
Power On
LLOP
HWT/HCT
LFL
DG ON
Emer.
canopy TestReset
StartStop
Engine Safety Unit
Enertrak
Trip
Ok
Voltage Protection Relay EVPR-1010
Prog.
DG Controller & Relay Enertrak
IT-3 EPIP, RIICO Industrial Area, Sitapura, Jaipur (Raj.)
Tel. / Fax 0141-277076, # +91-8233000062
email : [email protected], [email protected]