Descriptive TechnicalDocumentation- Model-dependent -
DTD no. 12-9800
Model(s): T 9800, T 9820
05.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
This information should not be duplicated or passed on without Miele approval. All rights reserved. 05.12.2006, US_am
Contents
General Information
A Warning and Safety Instructions
B Modification History
C Technical Data
D Layout of Electrical Components
Function Groups
010 Housing, Front panel1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 010-24 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 010-34.1 Lid Remove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 010-34.2 Front panel Remove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 010-44.3 Side panel Remove. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 010-5
020 Door, Lock1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-12 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-22.1 Door lock (A2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-2
4 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-34.1 Door Remove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-34.2 Door hinge Remove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-34.3 Door hinge Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-44.4 Door lock (A2) Remove. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-4
030 Drum, rear bearing, sensor, heater bank1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-22 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-42.1 No-load detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-42.2 Residual moisture measurement . . . . . . . . . . . . . . . . . . . . . . . . . 030-42.3 Heater control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-52.4 Temperature limiter with manual reset (1F1, 2F1, 3F1) . . . . . . . . 030-52.5 NTC temperature sensor drying air (1R30) . . . . . . . . . . . . . . . . . 030-52.6 NTC temperature sensor heating/drying (2R30) . . . . . . . . . . . . . 030-52.7 Drum light (H3/6) (Interior drum light) . . . . . . . . . . . . . . . . . . . . . . 030-6
3 Fault Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-73.1 Temperature limiter with manual reset (F1) has tripped . . . . . . . 030-7
Descriptive Technical DocumentationDTD no. 12-9800 1
05.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
4 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-94.1 Heater bank Replace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-94.2 Rear bearing Replace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 030-10
031 Heating (Gas)1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-22 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-32.1 Gas unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-32.1.1 Gas solenoid valve (Y57). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-32.1.2 Gas ignition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-32.1.3 Safety time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-52.1.4 Temperature sensor heating/drying (2R30) . . . . . . . . . . . . . . . . . 031-52.1.5 Temperature limiter (1F1, 2F1) . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-6
4 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-74.1 Gas burner Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-74.2 Gas solenoid valve Remove. . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-94.3 Gas solenoid valve Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-114.4 Gas burner Remove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-134.5 Gas burner Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031-14
040 Motor, Fan1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 040-2
050 Air duct, Front bearing1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 050-2
090 Fascia panel, Control/Power electronic1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-22 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-32.1 Dryer function after a power interruption . . . . . . . . . . . . . . . . . . . 090-32.2 Programming function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-32.2.1 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-32.2.2 Programming function drying outcome (residual moisture)
Cottons/Hot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-32.2.3 Programming function drying outcome (residual moisture)
Permanent press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-32.2.4 Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-32.2.5 Programming function Additional cooldown phase. . . . . . . . . . 090-32.2.6 Programming function Prompt to clean air ducts . . . . . . . . . . . 090-32.2.7 Acoustical acknowledgment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-42.2.8 Conductivity setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-42.2.9 Stand-by . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-42.3 Residual moisture sensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-42.4 Overriding time control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-42.5 Insufficient air detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-52.6 Operating hours meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-5
3 Fault Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-63.1 LED Anti-Crease/End lights up solid. . . . . . . . . . . . . . . . . . . . . . . 090-63.2 LED Clean air paths lights up solid . . . . . . . . . . . . . . . . . . . . . . . . 090-73.3 LED Clean air paths flashes rapidly . . . . . . . . . . . . . . . . . . . . . . . 090-8
Descriptive Technical Documentation2 DTD no. 12-9800
This information should not be duplicated or passed on without Miele approval. All rights reserved. 05.12.2006, US_am
3.4 LED Rotary iron flashes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-83.5 LED Hand iron flashes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-93.6 All program LEDs flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-103.7 F 0 No fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-103.8 F 1 Short circuit in NTC temperature sensor heating/drying
(2R30) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-113.9 F 2 Open circuit in NTC temperature sensor heating/drying
(2R30) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-113.10 F 3 NTC temperature sensor drying air (1R30) Short circuit . . 090-133.11 F 4 NTC temperature sensor drying air (1R30) Open circuit . . 090-133.12 F 50 Motor stalls and heater is on for 3 seconds . . . . . . . . . . . . . 090-143.13 F 55 Overriding time limit exceeded, approx. 180 min . . . . . . . . . 090-143.14 F 66 Air leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-16
4 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-174.1 Programming mode summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-174.2 Demonstration mode Activate / Deactivate . . . . . . . . . . . . . . . . 090-194.3 Service mode summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-204.4 Program selection module (EW) - Service view. . . . . . . . . . . . . . 090-224.5 Program selection module (EW) and fascia support panel
Remove. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-22
100 Electrical system1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100-24 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100-34.1 Fuses Replace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100-3
Descriptive Technical DocumentationDTD no. 12-9800 3
05.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation4 DTD no. 12