Page 1: Model 7000XTR High Flow Rate Control ValveXTR+VALVE+SPEC.pdfModel 7000XTR High Flow Rate Control Valve ... •Soft water brine refill • Variable reserve ... Cycles Up to 6 cycles

Model 7000XTR High Flow Rate Control ValveP

art N

o. 4

2730

Rev

A 5

/08

Front (without cover)

t

The residential 7000XTR offers a two-line, sixteen character LCD backlit display for easy entering of master, diagnostic, and user programming. No need to memorize codes or letters to program or read screens! Time of day is maintained during power failures, offering peace of mind and steady, treated water as needed.

Features •Shiftkey:Allowsdigitselectioninuserandmaster programming modes •Diagnostics -Currentflowrate -Peakflowrate(canbereset) -Totalizer(canbereset) - Hours between last two regenerations - Hours since last regeneration -Volumeremaining(adjustable) -Softwareversion •Userprogrammingmode •Masterprogrammingmode •Programmableauxiliaryrelayoutput - Dry contact relay - Program entire regeneration - Program during cycle position •LEDstatusindicator -Blue:Inservice -Green:Inregeneration -Red:Error •Upto35GPMflowsforresidential/commercialsofteningand filtrationapplications •Reliableopticalelectronicseliminatemicroswitchpositioning •Electronictimerprovidesquicksetupandprogramming •Quick-connectclipsalloweasyinstallationandmaintenance •Regeneratesupto10cu.ft.softeners

Options •High-flowbypassvalve •High-flowdistributionsystem •Plumbingconnectionsin3/4"-1-1/2"NPT,BSPandSweat •Softwaterbrinerefill •Variablereserve •Meterdelayed,immediate,ortimeclockregeneration •Doublebackwash •Environmentalcover(NEMA-3Rrated) •Auxiliaryswitch •Filterorsoftenercontrolvalves

Back (without cover)t

Valve SpecificationsValve material Fiber-reinforcedpolymer

Inlet/Outlet 1"or1-1/4"NPTorBSP,1",1-1/4",1-1/2"Sweat

Cycles Upto6cycles

Flow Rates (50 psi Inlet) - Valve AlonePiston Standard HighFlow FilterContinuous 28 36 37Peak(25psidrop) 36 46 47Cv(flowat1psidrop) 7-1/10 9-1/5 9-1/2Max.backwash(25psidrop) 7 16 31

RegenerationDownflow/Upflow Downflow onlyAdjustablecycles YesTime available Upto240minutespercycle

Meter InformationMeteraccuracy +5/-8%(2-40gpm)Metercapacityrange(gal.) 1,000-9,900,000

DimensionsDistributor pilot 1-1/20"O.D.or32mmO.D.Drain line 3/4"or1"NPTQuickConnectInjectorbrinesystem 1610Brine line 3/8"or1/2"QuickConnectMountingbase 2-1/2"-8"NPSMHeight from top of tank 8"

Typical ApplicationsWater softener 8"-24"diameterFilters 8"-24"diameter

Additional InformationElectricalrating 24VAC,50/60HzMax.VA 15Estimatedshippingweight 11lbs.

Pressure Hydrostatic:300psiWorking:20-125psi

Temperature 34o-110oF