Download - Mitsubishi Power Systems Americas
UTSR 2012W ORKSHOP
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
Mitsubishi Power Systems Americas, Inc. October, 2012
C O M B U S T I O N T U R B I N E D E V E L O P M E N T E F F O RT S
A G E N D A
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
Thermal Cycle Long Term Perspective (High efficiency)
Japanese National Project (1,700 ºC Turbine Inlet Temperature)
Nuclear Combustion Turbine (Helium closed circuit)
Pebble Bed Modular Reactor, PBMR
Oxy-Fuel IGCC with Carbon Capture
(Central Research Institute of Electric Power Industry, CREIPI)
Fuel Cell based triple combined cycle
(New Energy & Industrial Technology Development Organization, NEDO)
M I T S U B I S H I P O W E R S Y S T E M S A M E R I C A S
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
Established in April 2001 HQ Lake
Mary, FL
Turbine Manufacturing
Facility, Savannah GA
Blade and Vane Manufacturing
Facility Orlando
Repair Facility
Orlando
$40MM
$91MM $133MM
$225MM
$550MM
2001 2006 2007 2009 2011
Cap
ital In
vestm
en
t In
itia
ted
$400 Million Inventory
7
1800
MPSA’S 11 YEAR GROWTH
MPSA HQ,
GT Repair Center
Field Service
Wind Turbine Blades
CT Blade & Vane
Manufacturing Center
Savannah Combustor
Manufacturing
Gas Turbine
Manufacturing
Rotor Service Facility
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
(1500+300)
T H E R M A L C Y C L E L O N G T E R M P E R S P E C T I V E
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
E F F E C T O F T I T O N P E R F O R M A N C E
50
55
60
TIT
D Class
F Class
G Class
J Class
C/C Efficiency
2192°F 2372°F 2552°F 2732°F 2912°F
1200°C 1300°C 1400°C 1500°C 1600°C
Early 2011
> 8,000 Actual Operating Hours 1997
C/C
EF
FIC
IEN
CY
(L
HV
%)
1 on 1 GTGCC / 60 Hz
Historical high fuel prices in
Japan
Commitment to reduce CO2
emissions
E F F I C I E N C Y O F T H E R M A L P O W E R G E N E R AT I O N
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
Gro
ss E
ffic
iency [%
]
40
45
50
55
60
65
70
1990 1995 2000 2005 2010 2015
USC(coal)
(LHV %)
75
GTCC (LNG)
② IGCC
②+③
IGCC + SOFC
① GTCC
(1,700℃)
③ GTCC + SOFC (LNG)
① GTCC (1,700 ℃)
② IGCC(Gasification)
③ GTCC + SOFC
(Hybrid Cycle)
J A PA N E S E N AT I O N A L P R O J E C T ( 1 , 7 0 0 º C )
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
J A PA N E S E N AT I O N A L P R O J E C T M O T I V AT I O N
Energy security :
Most of the energy resources in Japan are imported
Global Warming :
Kyoto Protocol target = 6% reduction of CO2 emission
Combined Cycle Power Plant :
Improved Performance (60% → 62-65% LHV)
Turbine Inlet Temperature :
Higher (1500ºC → 1700ºC)
Exhaust Gas Recirculation
With EGR
Without EGR
Low O2
High Efficiency Cooling Steam
Steam Air
Steam Air
Air
Steam
Profile
Shroud Turbulator
Steam/Air Hybrid Cooling
High Efficiency Compressor / Turbine
Multi Stage Analysis
Higher Loading
End Wall Treatment
Advanced 3D Airfoil
Shock Wave
Advanced Super Alloy
Better than MGA1400DS * Creep Strength :100℃ Higher with Same strength * Anti Oxidation:100℃ Higher Limit * Thermal fatigue:50℃ Higher with Same strength
Advanced TBC
Tem perature(℃)
The
rmal con
ductivity(kcal/m
h℃)
Advanced TBC
C onventional TBC
Feedback
Material Calculation system Evalu
atio
n o
f ap
plic
atio
n
Sele
ctio
n b
y e
xp
erim
en
t
Sele
ctio
n o
f can
did
ate
10E
5 k
ind
s o
f mate
rial
Cry
sta
l Data
Base
Navigation System
Various databases Calculation of
electronic state (band)
Selection of optimum candidate materials and estimation of their properties
J A PA N E S E N AT I O N A L P R O J E C T S C O P E
E X H A U S T G A S R E C I R C U L AT I O N
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
再循環ライン
再循環冷却器
ガスタービン 蒸気タービン
排ガスボイラ
再循環送風機再循環ライン
再循環冷却器
ガスタービン 蒸気タービン
排ガスボイラ
再循環送風機
Heat recovery
steam generator
Gas turbine Steam turbine
EGR cooler
EGR line EGR blower
ガスタービン
HRSG
蒸気タービン
吸気
再循環ライン 復水器
発電機
発電機
Steam condenser
Generator
Steam turbine EGR line
Generator
Gas turbine
Air intake
Blower
Cooler
Without EGR
With EGR ratio 35%
Hot spot
degC
Part of the Exhaust Gas from
HRSG branches out
and is mixed with fresh air and
introduced to compressor inlet.
temperature (CFD)
Plant image of GTCC with EGR
P E B B L E B E D M O D U L A R R E A C TO R
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
P E B B L E B E D M O D U L A R R E A C TO R
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
O X Y- F U E L I G C C W I T H C C S
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
M H I I G C C T E C H N O L O G Y
The plant will capture 90% of the CO2 and
transport is to a nearby oil field (EOR and
sequestration)
400MW plant operating flexibly to increase
generation of fertilizer during low electricity
demand.
Air Blown Technology
O2 Blown Technology
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
O2/CO2 Blown
Gasification
Dry Gas clean-up
under high CO
concentration
Oxy-fuel system and semi-closed combustion turbine system.
Simplified CO2 removal and Capture System without Shift
Reactor.
O2/CO2 Firing
Combustor
Oxygen
ガス ガス 化炉
ガス
精製
ガス
精製
CO 2 圧縮 圧縮 Storage
ガスタ
ービン
ガスタ
ービン
排熱回 収ボイラ
排熱回 収ボイラ
蒸気タービン 蒸気タービン
CO 2 CO 2
ガス Gasifi
cation ガス
精製
GCU
CO 2 圧縮 Comp.
ガスタ
ービン
Gas
turbine 排熱回 収ボイラ
HRSG
蒸気タービン Steam turbine
CO 2 CO 2
Coal
Oxygen
Central Research Institute of Electric Power Industry
O X Y- F U E L I G C C P R O J E C T
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
O X Y- F U E L I G C C P R O J E C T
O2/CO2
Blown
Gasification
Semi-closed
Gas turbine
(O2/CO2
Firing Combustor)
石炭
ガス化炉
石炭
ガス化炉 フィルタ ( 集じん)
フィルタ ( 集じん)
酸素
製造設備
酸素
製造設備
燃焼器 燃焼器
Regenerator
汽水
分離器
汽水
分離器
HRSG
圧縮機 圧縮機
蒸気ター ビン
CO 2
O 2
CO 2
Steam
CO 2 + H 2 O
環境
設備
環境
設備 復水器
復水ポンプ
復水器
復水ポンプ
圧縮機 ガスター ビン
乾式
脱硫
乾式
脱硫 石炭
ガス化炉 Gasification フィルタ
( 集じん) Dust Filter
酸素
製造設備 ASU
燃焼器 Combustor
汽水
分離器
Water
Separator
圧縮機 Comp. 圧縮機 Comp.
蒸気ター ビン
Steam
turbine
Heater
Coal
CO 2
O 2
CO 2
Storage
CO 2 + H 2 O
環境
設備
Hg Removal
復水器
復水ポンプ Condenser
圧縮機 Comp.
ガスター ビン
Gas turbine
乾式
脱硫
Dry
DeSOx
Dry Gas
Clean-up
F C B A S E D T R I P L E C O M B I N E D C Y C L E
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
N E D O 2 0 0 K W S O F C M G T C O M B I N E D C Y C L E
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
Target Result
Systems 200kW Class
Power Output
SOFC 204kW-DC (188kW-AC)
MGT 41kW-AC
Total 229kW-AC
Electrical Efficiency
> 50% 52.1%-Net AC as LHV
Project Results (2004~2009)
Natural Gas
Exhaust Gas
Inverter
Air
Micro Gas Turbine
Recirculation
Blower
SOFC
Combustor
Recuperator
SOFC-MGT Power System
Module
Cartridge
Sub-Module
2 5 0 K W S O F C M G T C O M B I N E D C Y C L E
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
Spec Plan for Demonstration System
Capacity:250kW class (Net)
Efficiency:55% over (LHV/Net)
Total Heat Efficiency:73% over(Hot water)
Fuel:City gas
Footprint: 14m×5m=70m2
MGT
SOFC Vessel
TOYOTA MGT MST-250H
L A R G E S C A L E T R I P L E C O M B I N E D C Y C L E
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.
410MW
1600℃
460℃ 680℃
SOFC
Inverter
Air
Natural
Gas
(NG)
Gas Turbine
(G/T)
Steam turbine
Heat Recovery Steam
Generator
Exhaust
gas
condenser
Efficiency : >70%(LHV Net) SOFC Durability : >90,000 hours
T H A N K S F O R Y O U R AT T E N T I O N
This document and any attachments contain proprietary information and are the sole and exclusive property of Mitsubishi Power Systems Americas, Inc., “MPSA”. Your receipt of this information is an acknowledgement of a
confidential relationship between you and MPSA. This information is to be used solely by you for the purpose for which it is furnished. Neither these documents, nor any information obtained there from is to be reproduced,
transmitted, disclosed, discussed with any third party, or used otherwise, in whole or in part, without first receiving the express written authorization of MPSA.