Download - Microwave Site Master™ S820E
Microwave Site Master™ S820E“Site Master: Proven Accuracy and Reliability
you can trust”
Slide 1
Advanced Architecture
World’s first 40 GHz handheld cable & antenna analyzer = widest frequency coverage
Highest Dynamic Range 110 dB typical
Highest corrected directivity = highest measurement accuracy
The most built-in Waveguide calibration support, 10 bands standard + 4 custom
Full 4 receiver VNA architecture
Will support full reversing S-Parameter measurements (Future VNA Option)
1 Hz frequency resolution across full range of operation, even up to 40 GHz
Slide 2
1 MHz to 8, 14, 20, 30, 40 GHz Cable and Antenna AnalyzerHighest RF Immunity (+17 dBm)
250 x 177 x 61 mm (10.0 x 7.1 x 2.4 in) <3.0 kg (6.6 lbs)
Advanced Architecture
Uses same sampler technology as our premium VectorStar™ VNA models
Instant On from standby mode
Highest RF Immunity +17 dBm
650 us/point measurement speed typical
New efficient circuitry delivers >4 hour battery life
Rugged K(m) connectors on units 20 GHz and above. Easily convert to N(f) type without compromising field ruggedness
Measure long, embedded transmission systems easily with USB Transmission Sensor and USB Extenders
Slide 3
Ruggedized K(m) test ports easily and robustly converted to N(f)
using 71693-R adapters stands up to rugged field use
Easy to use (Integrated Help)
Integrated Help function
System Info Tab displays instrument info, hardware info and software info in one convenient screen
FAQ Tab displays multiple frequently asked questions. Touch any of the desired questions to reveal the answer. Some FAQ answers may include hyperlinks to the built-in User Guide for more detailed information
User Guide Tab provides easy access to the instrument’s full HTML based user guide. No longer need to carry a hardcopy with you in the field
Slide 4
Help screen illustrating multiple help selection tabs
Easy to use (Easy Guided Calibration)
Easy Guided Calibration
4 step Cal Setup allows you to select from a variety of calibration types, choose the calibration type that best suits your needs
Choose between Coaxial or Waveguide line type and following calibration steps will change accordingly
Select the DUT connector type, photos provide examples of what each connector typically looks like
Once DUT connector type is selected, the selection of built-in calibration kits is narrowed down to models that fit the chosen DUT type
Slide 5
S820E Guided Calibration simplifiescalibration process, minimizes errors
Easy to use (S820D-like Classic Mode)
S820D-like Classic Mode
Mimics the same basic GUI operation as the former S810D/S820D models
Supports 2-Port Cable Loss like the S8X0D series but uses extendable USB sensors instead of basic diode detectors
1-port measurements like the S8X0D models, no Smith Chart, no 1-port phase measurement helps to minimize confusion and reduce errors with new users
Switch to Advanced Mode when comfortable to gain access to more measurement types and more performance enhancing user control features like adjustable IFBW
Slide 6
820D-like Classic Mode GUISimilar flow of operation compared
to previous S8X0D models
Easy to use (All connectors conveniently located on top)
All connectors located on top
Allows instrument to be used while in protective softcase
No need to spend time looking for desired connector
Keeps sides clear for easy handling
Reduces risk of cabling getting caught or snagged on nearby items
Slide 7
1. RF Port 1 6. DC Power Input
2. RF Port 2 7. Two USB 2.0 Type A ports
3. BNC External Trigger Input 8. Ethernet Port 10/100 MB/s
4. BNC External Reference Input 9. 3.5 mm Aux Headphone Jack Output
5. USB Type Mini B
Versatile features and options (Advanced Mode)
Advanced Mode (Default)
Additional measurement types like Smith Chart, 1-Port Phase, Transmission (2 port) Transmission (Ext. Sensor)
Dual Display Format
Mix any 2 measurement types
Simultaneously measure RL/VSWR and 2-Port Cable loss using external sensor
Supports different calibration types for each display, EG:Upper trace has standard 1-port OSL calibration, lower trace has 2-Port external sensor transmission calibration
Slide 8
820E Advanced ModeDual Display
Versatile features and options (Advanced Mode Continued)
System Function Tool Bar
Provides one-touch access to common system functions like Preset, Save, Help, Screenshot, Mode Selector, Full Screen
User Defined Shortcuts
Quick one-touch access to six favorite user defined shortcuts. Recall favorite setups without having to open Menu screen or File menu
Additional Markers (8 vs 6) and additional marker functions
Slide 9
820E Advanced ModeSystem Function Tool Bar
And User Defined Shortcuts
Versatile features and options (High Accuracy Power Meter)
Measure True RMS power accurately using Anritsu MA series USB power sensors
As low as ±0.16 dB uncertainty
Supports Inline High Power Measurements with MA24105A
Easily configure upper/lower measurement limits and scale
Displays both dBm and Watts simultaneously
Choose which one you prefer as the main readout
Easily add offsets to correct for external loss/gain
Easily set relative measurements
Slide 10
820E-High Accuracy Power Meter
Versatile features and options (Standard Features)
3 Year Warranty (1 year on battery)
2-Port Transmission Measurements
2-Port Cable Loss Measurement (requires external USB Sensor)
High Accuracy Power Meter (requires external USB Sensor)
Ethernet 10/100 port
Remote Control/PC File Transfer
3 USB ports (2 Type A, 1 Type mini-B)
Remote Control/PC File transfer
Peripheral device support
Large Internal Memory
Internally store >2000 files
Sweeps, setups, screenshotsSlide 11
820E-0720 includes two 71693-R ruggedized adapters
as standard accessories
Versatile features and options (Standard Features)
Built-in GPS support (requires 2000-1723-R)
10 user selectable languages
Fast preview of stored sweeps
Large 800 x 600 8.4” Easy to read High Resolution TFT Touchscreen
Supports Daylight & Nighttime modes
Touch screen provides efficient GUI and ease of use, with or without gloves
Alphanumeric keyboard
EZ Name Quick Matrix for fast saving
Can lock touch screen and use cursor mode or USB mouse for instrument control
Slide 12
820E-0720 includes two 71693-R ruggedized adapters
as standard accessories
Versatile features and options (Standard Features)
Active Thermal Management
Allows for faster warmup
Provides superior measurement stability
Passes stringent MIL-PRF-28800F Section 4.5.6.3 Explosive Atmosphere Requirement
Increases MTBF and reliability
Hi Capacity Li-Ion field replaceable battery
Extend field operating time by adding a spare optional battery
Hot swappable when externally powered
S820E-0720 model comes standard with two 71693-R ruggedized K(f) to N(f) adapters
Slide 13
820E-0720 includes two 71693-R ruggedized adapters
as standard accessories
Versatile features and options (Standard Features)
easyTest™ Tools
Generate and share measurement script files among multiple users
Display images, work instructions, details
Allows multiple users to achieve consistent results with reduced errors
Saves valuable time in the field
Line Sweep Tools (LST) Software
Edit sweeps, rename, archive
Generate PDF or HTML reports
Convert RL/VSWR to DTF
Convert RL/VSWR to Smith Chart
Slide 14
820E-0720 includes two 71693-R ruggedized adapters
as standard accessories
New accessories supporting S820E (New calibration kits)
New series of high performance coaxial calibration OSL/TOSL kits
Specified across full instrument operating temperature range: -10°C to +55°C. This is an industry leading first
Newly developed and manufactured by Anritsu, not 3rd party OEM like most competitor’s offerings
Provides unbeatable performance up to 40 GHz.
K type (2.92mm) mechanically compatible with SMA and 3.5mm connectors
1-year recommended calibration cycle
Slide 15
OSLX50A-XX, TOSLX50A-XXHigh performance, full temperature
Coaxial Calibration Kits
New accessories supporting S820E (New calibration kits)
New series of high performance coaxial calibration OSL/TOSL kits
Male and Female Models with through component have equal electrical length
Each calibration kit comes with its own soft case pouch, and includes hardcopy of technical data sheet
Cal coefficients are built into S820E firmware, just select the model and the analyzer takes care of the rest
Other Anritsu hand held analyzers will support new calibration kits via future firmware updates
Slide 16
OSLX50A-XX, TOSLX50A-XXHigh performance, full temperature
Coaxial Calibration Kits
New accessories supporting S820E (New Flexible Cables)
New series of 40 GHz high performance phase-stable test port extension cables
Available with Ruggedized K(f) connectors to mate securely to S820E test ports
Available with standard K type connectors
Can be used with Anritsu bench top VNA’s like VectorStar™ and Lightning™
Provides best performance/price ratio
Highly flexible for easy connection and usage
Available in 0.6m and 1.0m lengths
Slide 17
14 Series Phase-Stable Flexible Cables
New accessories supporting S820E (USB Transmission Sensor)
New SC8268 USB Transmission Sensor
Designed to optimize 2-Port cable loss measurement/2-Port Transmission (Ext. Sensor) measurement
Provides full coverage from 1 MHz to 40 GHz
Delivers most accurate results with lowest uncertainty
Slide 18
SC8268 USB Transmission Sensor
New accessories supporting S820E (USB Extender + Cat 5e)
New 2000-1717-R USB Extender
Extends USB Sensor up to 85m for measuring 2-Port cable loss on embedded cables, or on any DUT with ends located physically far from each other
Completely passive, requires no additional power source
Use with standard Cat 5e cable available everywhere (Cat 6 recommended for best results)
Use with 2100-28-R Cat 5e cable to extend up to 22.5m or purchase custom length from local cable supplier
Slide 19
S820E shown with 2000-1717-R USB Extender and 2100-28-R cable and SC8268 USB Transmission Sensor
Microwave Site Master™ S820E Cable/Antenna Analyzer
Slide 20
Advanced architecture, Easy to use, Versatile features and options
“Site Master: Proven Accuracy and Reliability you can trust”