Get Universal Connectivity fServer.
MatrikonOPC Universal SCADA Serdevices, protocols and APIs. Matrito support most popular PLC protobetween vendors. Here is a list of
UCS Plug-in for DNP3 UCS Plug-in for IEC 60870 UCS Plug-in for Lufkin Mod UCS Plug-in for Modbus UCS Plug-in for OMNI Flow UCS Plug-in for ROC/ROC+
Supported OPC Specifications:
OPC A&E (OPC Alarms and OPC DA (OPC Data Access) OPC DA (OPC Data Access) OPC DA (OPC Data Access) OPC DA (OPC Data Access) OPC HDA (OPC Historical D OPC HDA (OPC Historical D OPC Security 1.00 OPC Unified Architecture
Advanced MatrikonOPC Server
Advanced functions make OPC inteprocess data, and make OPC soluti
Functionality consists of a collectiocombinations depending on each
OPC Security:Nativcrucial for implement
DCOM based, "all-or-
complete control oveper-item basis. Gran
intentional un-authorlayer to a systems o
Device Communica
the OPC Server to acneed for specialized
MatrikonOPC UniSCADA Server
r all your SCADA connectivity needs
er is a single OPC Server that provides connonOPC Universal SCADA Server offers a wideols delivering a cutting edge and new horizoatrikonOPC SCADA Connectivity Server Plug
us
Computers
vents) 1.1
1.0a
2.0
2.05a
3.0
ta Access) 1.1
ta Access) 1.2
Functions
gration easier, allowing MatrikonOPCs latestons more secure and reliable. MatrikonOPC S
n of components engineered to work togetheatrikonOPC servers requirements.
e support for the OPC Foundation's OPC Secuing secure OPC architectures. Instead of relyi
nothing" OPC data access permissions, this f
r item browsing, adding, reading, and writinglar control over data access helps prevent a
ized OPC data access. This role based securiterall Defense-in-Depth strategy.
tion Redundancy:Maximize OPC data relia
cess multiple data-sources in a redundant fasardware and/or additional custom software.
versal
in one OPC
ctivity to multiplerange of plug-insof connectivity
-ins:
servers to bettererver Advanced
in various
rity specification isng on global,
nction offers
- on a per-user- cidental or
y adds another
ility by enabling
hion without the
-
8/14/2019 MatrikonOPC Server for SCADA UCS Datasheet
2/2
Data Calculations:
the OPC Server side.MatrikonOPC servers
network traffic volum
Alarms and EventsEvents based on thebased on the calcula
Engine. The Matrikon
type, severity, and c
Maximum InteropeHDA, and OPC A&E s
MatrikonOPC serversmaximum interopera
Offline Mode:develServer configuration
items even when the
plant commissioning;the project, when all
now be run at any ti
User Defined Tag nMatrikonOPC server.
MatrikonOPC Aliasing
OPC items.Under Development:
This OPC Server is currently under
specifications, plug-in may get add
MatrikonOPC U
SCADA Server
MatrikonOPC servers allow processing of raw
Using a variety of math functions, constants,help reduce OPC client side computing requir
e by performing data conditioning right on th
:MatrikonOPCs Server enables users to triggOPC items value. Also, Alarms and Events caed value of pre-processed items using the po
OPCs Advanced Framework enables client fil
tegory and is OPC Compliant.
rability:Strict adherence to the OPC Foundaecifications. Backwards compatible and fully
strictly adhere to the OPC Foundations specibility with other vendors OPC products.
oped to aid system-integration; this functionby allowing OPC Clients to access data from
underlying data-source is not available. For
instead of delaying HMI graphic screen testithe OPC Servers' data-sources are available
e using the Offline Mode random test data.
ames:Enables the creation of virtual OPC ItWhether used for testing or for user-defined
extends all MatrikonOPC servers to work wi
development. Depending on the course of th
ed or removed upon suites release. Please b
iversal
OPC item data on
and equations ements and
e OPC Server side.
er Alarms andn be triggeredwerful Calculation
ering by event
tions OPC DA, OPCcompliancy tested,
fications to ensure
lity simplifies OPCll configured OPC
xample: during
g until the end ofsuch tests can