Philips CR444B W30L120 1xLED88/840 AC-MLO / Luminaire Data Sheet

Luminous emittance 1:

Luminaire classification according to CIE: 100CIE flux code: 69 93 99 100 100

LED cleanroom – hygienic and efficient

Customers operating highly hygienic facilities require special IP65, easy-to-clean, dust-free luminaires that meet all lighting requirements and norms. Moreover, to ensure the integrity of these areas (and stay within budget), they also need to minimize costly downtime and maintenance.

With the latest LED engine on board, this LED cleanroom luminaire represents the ideal solution, delivering market-leading energy performance – far beyond fluorescent solutions – over 50,000 hours of maintenance-free operation. This means extremely low operational cost over the total lifetime of the luminaire, and so an excellent financial return on investment.

Luminous emittance 1:

Page 1

Project 1

01.12.2014

OperatorTelephone

Faxe-Mail

Room 1 / Summary

Height of Room: 2.743 m, Mounting Height: 2.743 m, Light loss factor: 0.80

Values in Lux, Scale 1:155

Surface [%] Eav [lx] Emin [lx] Emax [lx] u0

Workplane / 546 29 1000 0.053

Floor 67 328 7.03 806 0.021

Ceiling 86 223 111 356 0.498

Walls (4) 86 111 12 468 /

Workplane:Height: 0.760 mGrid: 128 x 128 Points Boundary Zone: 0.000 m

Illuminance Quotient (according to LG7): Walls / Working Plane: 0.219, Ceiling / Working Plane: 0.409.

Luminaire Parts List

Specific connected load: 10.00 W/m² = 1.83 W/m²/100 lx (Ground area: 120.00 m²)

No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]

1 15Philips CR444B W30L120 1xLED88/840 AC-MLO (1.000)

6300 6300 80.0

Total: 94500 Total: 94500 1200.0

Page 2

Project 1

01.12.2014

OperatorTelephone

Faxe-Mail

Room 1 / Luminaire parts list

15 Pieces Philips CR444B W30L120 1xLED88/840 AC-MLOArticle No.: Luminous flux (Luminaire): 6300 lmLuminous flux (Lamps): 6300 lmLuminaire Wattage: 80.0 WLuminaire classification according to CIE: 100CIE flux code: 69 93 99 100 100Fitting: 1 x LED88/840/- (Correction Factor 1.000).

Page 3

Project 1

01.12.2014

OperatorTelephone

Faxe-Mail

Room 1 / Photometric Results

Total Luminous Flux: 94500 lmTotal Load: 1200.0 WLight loss factor: 0.80Boundary Zone: 0.000 m

Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²] direct indirect total

Workplane 408 138 546 / /

Floor 235 92 328 67 70

Ceiling 0.00 223 223 86 61

Wall 1 14 138 151 86 41

Wall 2 11 94 105 86 29

Wall 3 9.05 67 76 86 21

Wall 4 26 88 114 86 31

Uniformity on the working planeu0: 0.053 (1:19) Emin / Emax: 0.029 (1:35)

Illuminance Quotient (according to LG7): Walls / Working Plane: 0.219, Ceiling / Working Plane: 0.409.

Specific connected load: 10.00 W/m² = 1.83 W/m²/100 lx (Ground area: 120.00 m²)