©Mammoth-WEBCO, Inc.
1
Mammoth Water-Source Heat PumpsMammoth Water-Source Heat Pumps
©Mammoth-WEBCO, Inc.
2
Introduction to Mammoth-WEBCOIntroduction to Mammoth-WEBCO
1935 - Began as Brown Sheet Iron and Steel Company manufacturing industrial gravity and forced-air furnaces
1953 – Acquired by private investors and renamed Mammoth Furnace Company and was the largest industrial furnace manufacturer
1965 – Acquired by Lear Siegler, Inc. and expanded into Heat Pump and Coil manufacturing
1986 – Acquired by Nortek, Inc. and joined their CES Group, Inc., largest group of custom HVAC manufacturers in North America
2009 – WEBCO, Inc. merged with Mammoth, Inc. to form Mammoth-WEBCO, Inc.
©Mammoth-WEBCO, Inc.
3
You’ll Find Mammoth In Every MarketDelivering custom-engineered air conditioning solutions
You’ll Find Mammoth In Every MarketDelivering custom-engineered air conditioning solutions
Manufacturing
Education
Healthcare
Offices Pharmaceutical
High-Tech
Food Processing
Hotel/Motel Retail
Amusement
Government
Hospitality
©Mammoth-WEBCO, Inc.
4
integrated Prefabricated Equipment Centers (iPEC™)
Custom chillers and chiller plants ULTRALINE™ packaged DX
Roof-mounted air systems V-Cube™ floor-by-floor self-
contained RMZ Vari-Zone Custom DX and
multi-zone rooftop units And…
We Continue to Grow Our CapabilitiesWe Continue to Grow Our Capabilities
©Mammoth-WEBCO, Inc.
5
Mammoth Water-Source Heat PumpsMammoth Water-Source Heat Pumps
Water-source / Ground-source heat pump solutions
Horizontal and vertical, indoor configurations
Low-sound condominium unit
©Mammoth-WEBCO, Inc.
6
Holland, Michigan PlantHolland, Michigan Plant
New Factory Building - 45,000 Square Feet Manufactures All Water Source Products Manufacturing heat pumps for over 35 years
©Mammoth-WEBCO, Inc.
7
Small Single Circuit Horizontal And Vertical UnitsSmall Single Circuit Horizontal And Vertical Units
10 different sizes from ¾ ton to 6 ton. “N” vintage equipment, available in
standard and low (geothermal) temp applications.
Horizontal units:▼ Standard and mirror image, end discharge ▼ orientations available.
Vertical Units:▼ Right and left hand orientations.
©Mammoth-WEBCO, Inc.
8
Horizontal & Vertical UnitsGeneralHorizontal & Vertical UnitsGeneral
Galvanized G60 steel casing Access panels; compressor section, fan
section and electrical box 2-sided filter bracket with 1" thick filter Threaded female NPT water connections Condensate drain connection Supply duct connection Fully insulated with 3/4", 1½ lb. coated
fiberglass
©Mammoth-WEBCO, Inc.
9
Medium Horizontal LineMedium Horizontal Line
070H 6 ton 086H 7 ton 100H 8 ton 120H 10 ton 142H 12 ton
©Mammoth-WEBCO, Inc.
10
Medium Vertical UnitsMedium Vertical Units
070V 6 ton 086V 7 ton 100V 8 ton 120V 10 ton 142V 12 ton
©Mammoth-WEBCO, Inc.
11
V-Cube SlimLarge Vertical Units -V-Cube SlimLarge Vertical Units -
170V 14 ton 210V 17 ton 270V 22 ton 310V 25 ton 360V 30 ton 440V 37 ton 540V 49 ton
©Mammoth-WEBCO, Inc.
12
V-Cube SlimV-Cube Slim
14 through 49 Tons (Sizes 170-540)
Dual Scroll Compressor Units High EER’s & COP’s Quiet Operation Thermal Expansion Valves Heat Pumps (sizes 170-360)
or Cooling Only Optional VAV, Waterside
Economizers, Hot Gas Reheat, DDC Controls, Double Wall, …
©Mammoth-WEBCO, Inc.
13
100% Outside Air Units100% Outside Air Units
©Mammoth-WEBCO, Inc.
14
100% Outside AirSizes100% Outside AirSizes
Small Cabinet ▼ Size 071 Nominal 6 tons▼ Size 111 Nominal 9 tons▼ Size 141 Nominal 12 tons▼ Size 181 Nominal 15 tons
Large Cabinet▼ Size 221 Nominal 19 tons▼ Size 271 Nominal 23 tons▼ Size 321 Nominal 28 tons▼ Size 381 Nominal 32 tons
©Mammoth-WEBCO, Inc.
15
100% Outside AirUnit Features100% Outside AirUnit Features
Dual scroll compressors Thermal expansion valves Multi-blade low leak outside air damper with motor. 2" thick, 30% efficient pleated filters
▼ Additional 4” filters are optional Four-row evaporator coil ( six-row optional ) IAQ drain pan with side condensate drain connection. Hot gas reheat coil for dehumidification Hot gas by-pass Foil-faced foam insulation - no fiberglass. Belt drive fan assembly. Optional Mammoth MDDC controls.
©Mammoth-WEBCO, Inc.
16
Water-to-Water UnitsWater-to-Water Units
1 thru 30 tons Includes:
▼ Compressor▼ Source side HX▼ Load side HX▼ TX valve
Unit can heat or cool water Part of the High Efficiency Unit Family
©Mammoth-WEBCO, Inc.
17
MCHH units“Condo Heat Pumps”MCHH units“Condo Heat Pumps”
Mechanical cooling, hot water heating.
NC sound levels – 30 heating, 36 cooling.
Designed for closet installation.
Positive water shut off.
©Mammoth-WEBCO, Inc.
18
What’s Coming?What’s Coming?
“U” vintage single circuit 410A systems. “M” vintage twins & Quads 410A systems. “E” series large twin and quad circuits (410A). “D” vintage make up air units, (410A)
indoor/outdoor applications. “K” vintage water to water units, 5 to 50 tons,
(410A).
©Mammoth-WEBCO, Inc.
19
“E” Vintage Large Units“E” Vintage Large Units
Coming soon: “stock” cooling only, VFD, 410a refrigerant, double wall construction, fan wall design, pre-painted cabinet, ESP capability of up to 3”, Mammoth DDC controls,
Sizes available: 170 / 14 ton 210 / 17.5 ton 270 / 22 ton 310 / 25 ton 360 / 30 ton 440 / 40 ton 540 / 45 ton 620 / 52 ton 720 / 60 ton
20©Mammoth-WEBCO, Inc.
Control OptionsControl Options
©Mammoth-WEBCO, Inc.
21
HP-4 MicroprocessorHP-4 Microprocessor
Incorporated in all Mammoth heat pumps. High & low voltage protection. Random start time delay from 5 to 35 seconds. Compressor anti-short cycle protection (5min.) Electronic condensate alarm. Compressor lock out with auto reset. Fan interlock, with compressor operation. Emergency shut down / field supplied signal. Dry contacts for fault indication to DDC control. Aux contacts with compressor operation. Test pin jumper / disables timing circuits for
testing. LED fault identification / status indication Removable terminal strip for thermostat wire
connections.
©Mammoth-WEBCO, Inc.
22
HP-4 MicroprocessorHP-4 Microprocessor Room temperature control
▼ Can be used with any HEAT PUMP T-stat.▼ Mammoth heat pumps fail to heat (RV)
energized for cooling (“O”) terminal.▼ LED unit status codes:▼ “on” steady = Normal operating mode▼ 1 flash = High or low pressure trip.▼ 2 flashes = Emergency shut down (by others)▼ 3 flashes = Auxiliary switch fault.▼ 4 flashes = Condensate alarm▼ 5 flashes = Low voltage fault▼ 6 flashes = High voltage fault▼ 4 tries on auto re-set in 6000 seconds (1.6 hrs)
Lock out occurs, and must be re-set manually. (remove call for compressor at t-stat or cycle power to unit)
©Mammoth-WEBCO, Inc.
23
HP-4 MicroprocessorTypical WiringHP-4 MicroprocessorTypical Wiring
P1 terminal block (t-stat wiring)
P1-8 lock out alarm out put
P1-7 Call for compressor “Y”P1-6 NSB signal
P1-5 Supply Fan “G”
P1-4 24VAC (-)
P1-3 24VAC (-) “O”P1-2 2 hr overrideP1-1 24VAC (+) “R”
©Mammoth-WEBCO, Inc.
24
HP-4 MicroprocessorTypical WiringHP-4 MicroprocessorTypical Wiring
Other contact points / P2 terminal strip
P2-8 A.D. Contacts (NC)
P2-7 A.D. Contacts (com) P2-6 A.D. Contacts (NO)
P2-5 Unoccupied Input P2-4 Emergency Shutdown
P2-3 24 VAC (-)
P2-2 Dry Contacts Alarm
P2-1 Dry Contacts Alarm
©Mammoth-WEBCO, Inc.
25
Mammoth DDC controlsMammoth DDC controls
I/O Zone 560 Space temperature control 5 digital Outputs, 6 universal
inputs. 100% stand alone control. Capable of communication: via
BACnet, Modbus, N2, Lon talk. Includes communication with
intelligent space sensors, and keypad/display units.
For use with standard CAV heat pumps without water side economizers or hot gas re-heat.
Orders must include minimum of one key pad per order.
©Mammoth-WEBCO, Inc.
26
Supply air temp / monitor only
Water HX LWT
Water HX EWT
(thermistor/dry contact) net work
Comp Lckt / overflow, compr#1HP-4 alarm, comp#2 alarm
Load shed, Comp#1Q* HP4 alarmComp#2Q* HP4 alarm
Emergency shut down, External start, dirty filter*
Typical WiringTypical Wiring
©Mammoth-WEBCO, Inc.
27
“Rnet”Room/return air Temperature (RS Std)Or RS Pro
Fan start
Call for #1 comp
Call for #2 comp.
Reversing valve
Common alarm
Typical WiringTypical Wiring
©Mammoth-WEBCO, Inc.
28
Mammoth DDC controlsMammoth DDC controls
I/O Zone 583 Space temperature control 5 digital outputs, 8 universal inputs. 3 analog
outputs 100% stand alone control. Capable of communication: via BACnet,
Modbus, N2, Lon talk. Includes communication with intelligent space
sensors, and keypad/display units. For use with standard CAV heat pumps with
water side economizers or hot gas re-heat. Orders must include minimum of one key pad
per order.
©Mammoth-WEBCO, Inc.
29
I/O Zone 583I/O Zone 583
Typical wiring the same as 560 except 583 has three analog outputs
Analog outputs require DC relay for single stage, USC for multi stage or actuator for modulation of control
Outputs normally used for re-heat, 3ater side economizers or aux heat
Used for CAV with de-humidification and hot gas re-heat.
Also special applications with water to water units.
©Mammoth-WEBCO, Inc.
30
560 & 583 Control InterfaceRoom temperature control560 & 583 Control InterfaceRoom temperature control
RS Plus offers a local setpoint adjustment and override to an occupied mode and LED indication of current status.
RS Pro offer the same and a large LCD display.
Both sensors provide precision temperature measurement, communication capabilities, able to mate up with key pad for commissioning and maintenance.
RS Plus
RS Pro
©Mammoth-WEBCO, Inc.
31
I/O Flex 6126Discharge air controller
I/O Flex 6126Discharge air controller
6 digital outputs, rated at 5 amps @ 250VAC.
12 universal inputs, configurable for dry contact, thermistor/RTD, 0 to 20ma, 0-10 VDC.
6 analog outputs, 1&2 are 0-10 VDC or 0-20ma, outputs 3 through 6 are 0-10 VDC only.
Used in large twin, make up air units, primary use for units that have modulation control of heat source or control of VFD,
32©Mammoth-WEBCO, Inc.
WSHP Job ReferencesWSHP Job References
©Mammoth-WEBCO, Inc.
33
Pacific Bell ParkLocation: San Francisco, CAPacific Bell ParkLocation: San Francisco, CA
A wide range of units were installed throughout the park. They include small horizontal heat pumps, twin circuit verticals, V-Cube Lites, and V-Cubes
Mammoth worked with the developer to provide special arrangements and performance that better suited the layout of the park.
©Mammoth-WEBCO, Inc.
34
Viacom Location: New York, NYViacom Location: New York, NY
Viacom selected V-Cubes and horizontal heat pumps that worked with their open and closed ceilings. Quick delivery was a key point for many units.
Some units utilize DDC controls and VAV to service the studio and larger areas of the building.
©Mammoth-WEBCO, Inc.
35
Quality Living Assisted Care FacilityLocation: Omaha, Nebraska
Quality Living Assisted Care FacilityLocation: Omaha, Nebraska
Quality Living added a new east campus to their facility. The new campus utilized Mammoth high efficiency geothermal heat pumps.
The new addition operates more than twice total hours at less cost than the older campus with a conventional boiler and tower system.
©Mammoth-WEBCO, Inc.
36
Texas Motor Speedway CondominiumsFort Worth, TXTexas Motor Speedway CondominiumsFort Worth, TX
Mammoth was awarded the project because of energy savings, noise control, flexibility in right/left hand configuration and meeting the tight closet fit.
©Mammoth-WEBCO, Inc.
37
Sherman Hospital, 255 bedLocation: Chicago, ILSherman Hospital, 255 bedLocation: Chicago, IL
Worlds Largest Geothermal Hospital
Over $1.0 Million energy savings annually
732 Mammoth Water-to-Air Terminal Units
18 Governair RSA Air Handlers with Vestibules & Governair controls
©Mammoth-WEBCO, Inc.
38
Mammoth Water-Source Heat PumpsMammoth Water-Source Heat Pumps
How can we help you today?