Download - LNG – Fundamental Principles
![Page 1: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/1.jpg)
1 - 2010-09-26
TPG 4140 Natural Gas 2011LNG – Fundamental PrinciplesJostein Pettersen
![Page 2: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/2.jpg)
2 - 2010-09-26
Outline
• Why LNG?
• What is LNG ?
• Applications of LNG
• LNG trade and LNG chain
• Gas pre-treatment
• Gas liquefaction
• LNG storage and loading
• LNG transport
• LNG receiving terminals
![Page 3: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/3.jpg)
3 - 2010-09-26
Why produce LNG?LNG is mainly produced for transportation purposes•In situations where the gas market is far from the source of the natural gas itis more economical to transport the gas as LNG instead of in a natural gaspipeline.•LNG also offers greater flexibility than pipeline gas
![Page 4: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/4.jpg)
4 - 2010-09-26
What is LNG ? LNG = Liquefied Natural Gas
LNG is a cryogenic liquidA cryogenic liquid is the liquid form of any element or compoundthat liquefies at a temperature below –73 °C (-100 °F) at atmosphericpressure. Common cryogenic liquids are: Nitrogen, Oxygen, Helium, Hydrogen and LNG
• LNG is natural gas that has been cooled and condensed to a liquid
• At atmospheric pressure LNG has a temperature of about –162 ºC or -260 ºF
• LNG contains about 85-95 % methane• LNG is colorless, odorless, non-corrosive and non-toxic• Evaporated LNG can displace oxygen and cause human
suffocation• Flammability range, 5-15 vol % concentration in air• Autoignition temperature, 540°C
![Page 5: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/5.jpg)
5 - 2010-09-26
LNG Density1 m3 LNG correspondsto 600 Sm3 natural gas
S = Standard state, 15°C, 1 atm
At temperatures above -110 ºC LNG vapour is lighter than air
LNG is lighter than waterLNG Density: 450 kg/m3
Water density: 1000 kg/m3
![Page 6: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/6.jpg)
6 - 2010-09-26
Main components in LNG
Component Formula MW (kg/kmol) NBP (°C) NFP (°C)
Nitrogen N2 28.013 - 195.5 - 209.9
Methane CH4 16.043 - 161.6 -182.5
Ethane C2H6 30.07 -88.6 -183.3
Propane C3H8 44.097 -42.0 -187.7
nButane nC4H10 58.124 -0.5 -138.4
iButane iC4H10 58.124 -11.8 -159.6
nPentane C5H12 72.151 36.06 -129.8
MW=Molecular weightNBP=Normal Boiling PointNFP= Normal Freezing Point
One mol is defined as 6.022•1023 atoms/molecules of a substanceThe volume of one mol is 23.644 liters at standard conditions (15°C, 1 atm.)
![Page 7: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/7.jpg)
7 - 2010-09-26
Types of LNG plants• Base-load plants
Large plants which are directly based on a specific gas field development and are the main plants for handling the gas. A base-load plant has typically a production capacity of above 3 Mtpa (million tons per annum) of LNG. The main world-wide LNG production capacity come from this type of plants
• Peak-shaving plantsSmaller plants that are connected to a gas network. During the period of the year when gas demand is low, natural gas is liquefied and LNG is stored. LNG is vaporized during short periods when gas demand is high. These plants have a relatively small liquefaction capacity (as 200 tons/day) and large storage and vaporization capacity (as 6000 tons/day). Especially in the US many such plants exist
• Small-scale plantsSmall-scale plants are plants that are connected to a gas network for continuous LNG production in a smaller scale. The LNG is distributed by LNG trucks or small LNG carriers to various customers with a small to moderate need of energy or fuel. This type of LNG plants typically has a production capacity below 500 000 tpa. In Norway and China several plants within this category is in operation.
![Page 8: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/8.jpg)
8 - 2010-09-26
LNG Chain
Gas Production
Pipeline
LNG Plant
LNG Shipping
LNG Receiving Terminal
PowerGeneratio
n
GasDistributio
n
ElectricityTransmissio
n
GasMarketing
EndUser
EndUser
Air Liquefaction:Nitrogen, Oxygen,
ArgonRemote Cooling
Super Freeze/ Cryogenic Storag
e
Cold Energy Power Recover
y
15-20 % 30-45 % 10-30 % 15-25 %
Cost Distribution in the LNG value Chain – (numbers are indicative)
LNG Cold Utilization
![Page 9: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/9.jpg)
9 - 2010-09-26
Heating value and Wobbe Index
UHV=Upper Heating Value, LHV=Lower heating value
28.964MW
GHVspgr
GHVWobbeIndex ==GHV: Gross Heating Value (MJ/Sm3)
(same as Upper Heating Value)spgr: specific gravity (-)MW: Molecular weight (kg/kmol)
The final LNG product has requirements for heating value and wobbe index
Substance UHV UHV UHV LHV LHV LHVkJ/kg kWh/kg MJ/Sm3 kJ/kg kWh/kg MJ/Sm3
Nitrogen 0 0 0 0 0 0Methane 55496 15,42 37,66 50010 13,89 33,93Ethane 51875 14,41 65,97 47484 13,19 60,39Propane 50345 13,98 93,90 46353 12,88 86,45Butane 49500 13,75 121,69 45714 12,70 112,38Pentane 49011 13,61 149,56 45351 12,60 138,39
![Page 10: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/10.jpg)
10 - 2010-09-26
Gross Calorific Value range for various pipeline networks
![Page 11: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/11.jpg)
11 - 2010-09-26
Applications of LNG
• Pipeline gas for household and industry
• Gas fired power production
• Maritime fuel
• Fuel for cars and buses
• LNG cold utilization
![Page 12: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/12.jpg)
12 - 2010-09-26
Natural gas liquefaction plants
Source: CERA
Kenai
ShtokmanSnøhvit
Yamal
Marsa el Brega Sakhalin
Deltana
Peru LNG
Bolivia LNG
Arzew
Mariscal Sucre
AtlanticLNG Mauritania
Angola LNG
Yemen LNG
Gassi Touil Skikda
Idku Arun
Bintulu BruneiCentral SalawesiTangguh
IchthysSunrise
Darwin LNG
Browse BasinAustralia NWS 1-5
PlutoGorgon
PilbaraBontang
Baltic LNG
Bontang
Damietta
Equatorial Guinea
Akwa Ibom
Liquefaction Plant – Existing/ Under ConstructionLiquefaction Plant – Proposed
NIOC LNG
Persian LNG
Abu Dhabi LNG
Oman LNG
Pars LNG (Iran)QG IV
QG IIIQG IIQG I
RasGas 1-5RasGas 6/7
OK LNG
NLNG 1-6
OK LNG
Brass LNG
NLNG 7/8/9
![Page 13: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/13.jpg)
13 - 2010-09-26
Gas processing and liquefaction
![Page 14: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/14.jpg)
14 - 2010-09-26
Simplified LNG plant block diagram
Endflash
HHCExtraction
CH4/N2
Fuelgas
Power&
heat
(C5+) (C4 and C3)
(CO2 and H2S)
![Page 15: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/15.jpg)
15 - 2010-09-26
Air cooled condensers
Plant example: Atlantic LNG –Trinidad (Air cooled)
Compressors
Jetty
Jetty
Cold boxes(Heat exchangers)
![Page 16: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/16.jpg)
16 - 2010-09-26
Gas conditioning (pre-treatment)• Acid Gas (CO2 and H2S) removal
− Acid gas causes corrosion, reduces heating value, and may freeze and create solids in cryogenic process
− Typical requirements for LNG: Max 50 ppmv CO2, Max 4 ppmv H2S(ppmv - parts per million by volume)
• Dehydration (water removal)− Water will freeze in cryogenic process
− Typical requirement: Max 1 ppmw (weight) H2O
• Mercury removal− Mercury can cause corrosion problems, especially in aluminium heat exchangers
− Requirement: Max 0.01 µg/Nm3
![Page 17: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/17.jpg)
17 - 2010-09-26
MDEA process for CO2 removal
![Page 18: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/18.jpg)
18 - 2010-09-26
Water removal by adsorption • Adsorption in to a solid material
− Used in “deep” gas processing like Kårstø, Snøhvit with cold process systems
− Removal of smaller amounts of water
− Extreme dryness, down to 0.1 ppm
• Porous structure that contains very large internal surface area
− 200 – 800 m2/g
• Strong affinity for water
− 5 – 15 % by weight
• Solids like
− Molecular sieve (3A or 4A type)
− Silica gel
• Regenerative process
![Page 19: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/19.jpg)
19 - 2010-09-26
Water removal by adsorption
![Page 20: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/20.jpg)
20 - 2010-09-26
Natural gas path through liquefaction
pressure-enthalpy diagram (C1:89.7% C2:5,5% C3:1.8% N2:2.8%)
1
10
100
-900 -800 -700 -600 -500 -400 -300 -200 -100 0 100 200
Enthalpy [kJ/kg]
Pres
sure
[bar
a]
-200oC -150oC -100oC -50oC 0oC 50oC
PrecoolingLiquefactionSubcooling
Expansion
JT Throttling
End flash LNG
![Page 21: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/21.jpg)
21 - 2010-09-26
Liquefaction process
![Page 22: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/22.jpg)
22 - 2010-09-26
Vapour pressure of pure fluids relevant for LNG processes Refrigerant Vapour Pressure
1
10
100
-200 -150 -100 -50 0 50
Temp(C)
Pre
ssur
a(B
ara)
LNG Range
N2
C1 Ethylene
CO2
C2
C3
n-C4
![Page 23: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/23.jpg)
23 - 2010-09-26
Liquefaction process licensors –Base load LNG plants (3+ Mtpa)• Air Products and Chemicals Inc (APCI)
− World leader since since the 1970s – ca 80 operating trains− C3MR process ( ca 70 trains)− AP-XTM Hybrid (QatarGas II, III and IV, RasGas III: Six trains of 7.8 Mtpa each, Start up 2008)
• ConocoPhillips (Optimised) Cascade− Trinidad: Atlantic LNG - 4 trains− Egypt: Idku− Alaska: Kenai (Operating since 1969!)− Australia: Darwin LNG− Equatorial Guinea
• Shell DMR – Double Mixed Refrigerant (Sakhalin, 2 x 4.8 Mtpa –start-up 2007)PMR (same as C3MR – but parallel MR circuits) – no references
• Linde/Statoil MFC® Mixed Fluid Cascade Process (Snøhvit, 4.3 Mtpa – start up 2007)
• Axens Liquefin™ (No references)
Mtpa = Million tonnes per year
![Page 24: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/24.jpg)
24 - 2010-09-26
Simplified cascade process for natural gas liquefaction
MethaneEthylenePropane
NG12 °C-32 °C
1.4 bar 7 bar
-96 °C
1.4 bar 19 bar
LNG -155 °C
1.4 bar 45 bar
![Page 25: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/25.jpg)
25 - 2010-09-26
Cascade Process (ConocoPhillips)
![Page 26: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/26.jpg)
26 - 2010-09-26
Temperature stages in cascade process
![Page 27: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/27.jpg)
27 - 2010-09-26
Example of single-mix refrigerant cycle for natural gas liquefaction (Prico cycle)
LNG
NG
5 bar
30 bar
12 °C
-155 °C
12 °C
-155 °C -155,5 °C
6,5 °C
99,8 °C
Composition:
NG Refrig
C1 0.897 0.360
C2 0.055 0.280
C3 0.018 0.110
nC4 0.001 0.150
N2 0.028 0.100
![Page 28: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/28.jpg)
28 - 2010-09-26
Temperature – enthalpy diagram of Prico example
-200
-150
-100
-50
0
50
100
150
-1500 -1000 -500 0 500 1000 1500
Enthalpy, x 10^6 kJ/hr
Tem
pera
ture
, C
Mixed refrigerant dew point line
Mixed refrigerant bubble point line
NG bubble point line
NG dew point line
Mixed refrigerant 30 bar
Mixed refrigerant 5 bar
NG 60 bar
LNG
NG
5 bar
30 bar
12 °C
-155 °C
12 °C
-155 °C -155,5 °C
6,5 °C
99,8 °C
![Page 29: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/29.jpg)
29 - 2010-09-26
Hot/Cold Composite Curves for Single Mixed Refrigerant Cycle
-180
-160
-140
-120
-100
-80
-60
-40
-20
0
20
40
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Duty, x 10^6 kJ/hr
Tem
pera
ture
, C
![Page 30: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/30.jpg)
30 - 2010-09-26
C3MR Process
![Page 31: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/31.jpg)
31 - 2010-09-26
Heat exchangers
![Page 32: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/32.jpg)
32 - 2010-09-26
Kettle type heat exchanger
• Shell and tube exchanger with separator function
• Flooded
• Tube bundle submerged in boiling liquid
Refrigerant vapour to compressor suction
Refrigerant liquid feedRefrigerant liquidsupply (if needed)
Hot stream inlet
Hot stream outlet
![Page 33: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/33.jpg)
33 - 2010-09-26
Cryogenic Heat Exchangers
Plate-Fin Heat Exchangers
Spiral-Wound Heat Exchangers
![Page 34: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/34.jpg)
34 - 2010-09-26
Spiral Wound Heat Exchanger (SWHE)
• Picture showing Snøhvit subcooler (25-HX-102)
• Specialized ”proprietary” type of heat exchanger
• Large capacity in one unit
• Reasonably robust, and well proven in gas liquefaction
• Issues
− Complexity of thermal/hydraulic analysis
− Flow distribution on shell side
− Exclusive knowledge
− Leakage – but tubes can be plugged
![Page 35: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/35.jpg)
35 - 2010-09-26
![Page 36: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/36.jpg)
36 - 2010-09-26
![Page 37: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/37.jpg)
37 - 2010-09-26
Spiral Wound LNG Heat Exchanger
![Page 38: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/38.jpg)
38 - 2010-09-26
Plate fin (PFHE)• Stack of plain and folded plates• Brazed in vacuum furnace• Compact, multi stream capability• Pressures up to ca 120 bar• Issues
− Thermal stress− Flow distribution and flow
instability− For clean service only!− Limited size (brazing process)− Cannot be repaired or plugged
Fin height 5-10 mm
![Page 39: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/39.jpg)
39 - 2010-09-26
123456789
10111213
Block or CoreHeaderNozzleWidthStacking heightLengthPassage outletCover sheetParting sheetHeat transfer finDistribution finSide barEnd bar
![Page 40: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/40.jpg)
40 - 2010-09-26
Production of plate-finheat exchangers (Linde)
![Page 41: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/41.jpg)
41 - 2010-09-26
LNG storage and loading
![Page 42: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/42.jpg)
42 - 2010-09-26
LNG tank containment principles
![Page 43: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/43.jpg)
43 - 2010-09-26
• Pre-stressed concrete outer walls constructed by slipforming, sheathed internally with a gas-tight layer of nickel-alloyed steel.
• Inner tank in nickel-alloyed steel, separated from the outer walls by a layer of perlite - a variety of volcanic obsidian highly suitable for insulation
• Extra layer of steel and insulation at the transition between outer wall and tank bottom to protect it against strong local stresses should the inner tank begin to leak.
• Heating cables under the tanks will ensure that the ground remains above 0°C in order to prevent frost heaving.
Above-ground full-containment LNG tank design
![Page 44: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/44.jpg)
44 - 2010-09-26
Rollover - principles
T1ρ1
T2> T1ρ2< ρ1
evaporation
heatheat
Light components evaporatesDensity increases
ρ2 becomes larger than ρ1 due tocomposition changeRollover of the liquid phases may then occurThis gives a sudden pressureincrease due to flash vaporization
T = Temperature (°C)ρ = Density (kg/m3)
![Page 45: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/45.jpg)
45 - 2010-09-26
Typical storage and loading system
![Page 46: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/46.jpg)
46 - 2010-09-26
![Page 47: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/47.jpg)
47 - 2010-09-26
LNG ships
![Page 48: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/48.jpg)
48 - 2010-09-26
LNG transportation – technical aspects• LNG is transported at – 163 deg. C and at atmospheric pressure
• This extreme low temperature require that the LNG is transported and handled with special consideration, i.e.
− Completely separated from the ship’s hull
− LNG temperature must be maintained during the voyage – requiring efficient insulation of the cargo tanks
− All cargo handling equipment must be able to operate at the extreme low temperature of -163 degr. C
• Two basically different cargo containment systems are used:
− Self supported independent tanks (Moss Rosenberg spherical tanks, IHI SPB, cylindrical tanks)
− Membrane tanks (Gaz Transport and Technigaz (GTT))
• Market share between the two concepts has been about. 50/50 - but the membrane concept has been increasingly selected for recent newbuilding orders.
![Page 49: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/49.jpg)
49 - 2010-09-26
Spherical tank cargo containment systems (Moss Rosenberg )
![Page 50: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/50.jpg)
50 - 2010-09-26
Spherical LNG cargo tanks – pros & cons• Advantages
− Independent from the ship’s hull – hull stresses not transferred into the cargo tanks
− Very robust design
− No sloshing problems
− Can operate with partly filled tanks
− Allow simultaneous building of hull and cargo tanks
− Easy to inspect
− Easy to detect and repair leakages
• Disadvantages
− Low volumetric utilisation of the hull
− Larger physical dimensions for same capacity compared with prismatic tanks
− Visibility from bridge reduced compared with ships with prismatic tanks
− Require return cargo (‘heel’) on ballast voyage to keep cargo tanks cooled
![Page 51: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/51.jpg)
51 - 2010-09-26
![Page 52: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/52.jpg)
52 - 2010-09-26
LNGC – Membrane cargo containment system(GT No. 96, MK I and MK III, and CS1)
![Page 53: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/53.jpg)
53 - 2010-09-26
Mark III (Technigaz) Membrane system
![Page 54: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/54.jpg)
54 - 2010-09-26
Inside membrane tank
![Page 55: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/55.jpg)
55 - 2010-09-26
Membrane cargo containment system (GTT) – pros & cons
• Advantages− High volumetric utilisation of ship’s hull− Less sensitive to temperature changes as inner membrane (invar steel) has very low
thermal contraction coefficient− Limited need for heel on ballast voyage
• Disadvantages− Cargo tanks are an integrated part of the ship’s hull - hull stresses transferred to cargo
tanks− Does not allow simultaneous construction of hull and cargo tanks− Difficult to detect and costly to repair leakages− Restricted filling ratio
![Page 56: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/56.jpg)
56 - 2010-09-26
LNG CarriersGrowth in the average capacity
![Page 57: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/57.jpg)
57 - 2010-09-26
LNG Receiving Terminals
![Page 58: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/58.jpg)
58 - 2010-09-26
Gas quality parameters – N2 injection
![Page 59: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/59.jpg)
59 - 2010-09-26
Sabine Pass LNG TerminalArtist’s Rendition
Source: Cheniere Energy, Inc.
![Page 60: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/60.jpg)
60 - 2010-09-26
LNG receiving terminal - principles
![Page 61: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/61.jpg)
61 - 2010-09-26
Vaporizer options
• Need a heat source
Basically the following options are available (or a combination of them):
• Heat from seawater − Open Rack Vaporizers – ORV
• Heat of combustion, by burning a portion of the natural gas− Submerged Combustion Vaporizers – SCV
• Heat from waste heat recovery or by direct burning of natural gas− Direct Fired Heaters – DFH
• Heat from ambient air − Ambient Air Vaporizers - AAV
![Page 62: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/62.jpg)
62 - 2010-09-26
New technology entering the market• Offshore LNG terminals has been an issue since the early 1990s
• In general floating storage and re-gasification unit (FSRU) can be divided into two groups
− Near-shore terminals. Gravity based structures (GBS) sited at 15 to 25 meters water depth. Normally constructed in concrete, due to its durability and track record in offshore oil and gas operations in general. Concrete is also the preferred choice for secondary containment in the LNG storage system.
− Offshore terminals. For the far shore options several different designs have been proposed based on vessel design, barge design or partly submerged structures. As an alternative to traditional low temperature storage sub sea caverns have also been proposed.
![Page 63: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/63.jpg)
63 - 2010-09-26
Example of offshore solution: Høegh SRV
• Dedicated ships
• Required modifications:
− Connection for submerged turret buoy and flexible export riser
− Regasification plant onboard
− Send out capacity 400 t/h, i.e. about 7 days discharge time
− Weather limit for continous sendout: Hs = 11 m
![Page 64: LNG – Fundamental Principles](https://reader034.vdocuments.us/reader034/viewer/2022042513/56d6bfb41a28ab3016975544/html5/thumbnails/64.jpg)
64 - 2010-09-26
Thank you