Page 1: Liquid target system for New TPC experiment

Liquid target system for New TPC experiment

•System•Target cell•Performance in test experiment•Plan for next experiment•Perspective

Page 2: Liquid target system for New TPC experiment

L.T. System

CFRP (1mm)

Page 3: Liquid target system for New TPC experiment

Target

~500 mm145 mm

40 mm

33 m

m

25mm

Kapton Cell

Target stage

Temperature sensor (Cernox)

Page 4: Liquid target system for New TPC experiment

Target Cell (Kapton 125 um)Nagai manufacturing Co.,Ltd.( www.nagai-mfg.co.jp )Plastic molding, etc.

Leak test (2 atm) using N2 gas.

Page 5: Liquid target system for New TPC experiment

Shielding

Page 6: Liquid target system for New TPC experiment

Operation

• 145 mm   long target cell

Filled gas with 1.35 atm using default preserver tank (120x6 litter)

• Temperature controll (Lake Shore)

set requested temperature

The heat voltage is controlled automatically.

Page 7: Liquid target system for New TPC experiment

17K15.8K

Test  (Hydrogen)

Page 8: Liquid target system for New TPC experiment

For next experiment

100 mm longer

Page 9: Liquid target system for New TPC experiment

TargetCollimatorHole 31.7x24 mm

2 T

T=3 GeV, N=105, (x,y)=(8mm,4mm)

(In&Out&Upbar)No LH2 3 No buffer 11LH2 12

33x25 mm

Setup

(100)3 mm

Page 10: Liquid target system for New TPC experiment

Further

• Helium 4

The liquidized was achieved using copper cell at Suzuki co.

R&D for the target cell

Kapton Aramid, etc.