![Page 1: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/1.jpg)
adLIGO R&D 1LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Two SOS optics were used to represent the Reaction Mass and either the ITM or ETM masses. Optics had 3 degrees of freedom.
![Page 2: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/2.jpg)
adLIGO R&D 2LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Keyence CCD displacement measuring heads. Heads come with a target range and a ± working tolerance.
Laser output port.
CCD Camera
![Page 3: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/3.jpg)
adLIGO R&D 3LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
The heads propagate a 635nm beam to each of the 4 optic surfaces that reflect back to the CCD camera measuring the displacement.
![Page 4: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/4.jpg)
adLIGO R&D 4LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
The output values and settings can be set on the controller locally or on a laptop.
![Page 5: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/5.jpg)
adLIGO R&D 5LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Laptop settings
![Page 6: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/6.jpg)
adLIGO R&D 6LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Laptop grid screen showing the gap and optic thicknesses realtime.
GAP measurement shown is the value between the white cursors. Scale was set for 4mm between grids lines
![Page 7: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/7.jpg)
adLIGO R&D 7LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Beam propagation paths to the optic, reflected back to the CCD camera port
![Page 8: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/8.jpg)
adLIGO R&D 8LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T0802012.0” by ¼”optics S1 & S2 are parallel < 10 arc seconds.
Optic 1 in the test mass dummy is a 50% reflector.
Optic 2 in the
Reaction mass dummy is a 99% reflector
![Page 9: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/9.jpg)
adLIGO R&D 9LIGO-G9900XX-00-M
50% BS
(TEST MASS)
HR
(REACTION MASS)
AUTO COLLIMATOR
MONITOR &
RETICLE PATTERN
OPTICAL AUTOCOLLIMATOR METHOD
![Page 10: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/10.jpg)
adLIGO R&D 10LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Camera view from the autocollimator eyepiece showing a properly aligned reflection.
![Page 11: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/11.jpg)
adLIGO R&D 11LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Reticle pattern and cross hair as image is retro-reflected +/- 30 minutes scale.
Our tolerance for the parallelism is .08 degrees (~0.5mins) so we need to split the space between the tick marks.
![Page 12: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/12.jpg)
adLIGO R&D 12LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
Reticle pattern shown with optic shifted in pitch’d(up) and yaw’d (right)
![Page 13: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/13.jpg)
adLIGO R&D 13LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
This demonstrates a typical image when both optics are pitch’d & yaw’d off.
![Page 14: LIGO-G9900XX-00-M adLIGO R&D1 AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware (Keyence)T080201 Two SOS optics were used to represent](https://reader031.vdocuments.us/reader031/viewer/2022032723/56649d1b5503460f949f1162/html5/thumbnails/14.jpg)
adLIGO R&D 14LIGO-G9900XX-00-M
AdLIGO Bench Testing of Proposed Quad Alignment & Gap Setting Hardware
(Keyence)T080201
This image show both optics aligned in yaw, but the second optic is pitched up.