Download - Leax Arkivator Telecom Catalogue 2014 (2)
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
1/113
CONNECTORS • JUMPER CABLES
EMP & GROUNDING • CABLE CLAMPS
POWER SPLITTERS & TAPPERS
COMBINERS • ABSORBERS
• REPEATERS
ACTIVE DAS • PASSIVE DAS • ANTENNAS
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
2/1133Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
While all efforts have been made to provide accurate specifications at time of printing, Leax Arkivator Telecom AB
is not responsible for any errors or omissions in this catalogue. All specifications are subject to change without prior
notice and neither Leax Arkivator Telecom AB nor its employees may be held responsible for discrepancies between
the printed specifications and those actually in effect at any given time. Please check actual specifications at www.arkivator.se before ordering.
© Leax Arkivator Telecom AB, Sweden
All rights reserved. 2014 Leax Arkivator Telecom AB.
INFO & ORDER: [email protected]
WEB: www.leax.com
SALES OFFICE
Ordering products from Leax ArkivatorTelecom is easy. Orders can be placed
directly via telephone or e-mail.
Visit Leax Arkivator Telecom´s websitefor updated product specifications,mounting descriptions and much more.
Leax Arkivator Telecom AB
Stridsvagnsvägen 14
SE-291 39 Kristianstad, Sweden
PHONE: +46 (0) 8 752 02 20
CONTENTS
INTRODUCTION
CONNECTORS
FEEDER & JUMPER CABLES
EMP & GROUNDING
CABLE CLAMPS
PASSIVES
COMBINERS
REPEATERS
REPEATER ANTENNAS
INDOOR ANTENNAS
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
3/1134 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
LEAX Arkivator Telecom AB is a global technology supplier servicing the
coaxial and RF industry in both the broadcasting and telecom sectors. Our
focus is to develop and manufacture the most innovative, dependable and
long-lasting products on the market.
Building on traditionAt LEAX Arkivator Telecom, our focus is on the development and manu-
facture of innovative, long-lasting RF products offering superior reli-
ability and performance at a reasonable price for the worldwide market.
Previously Teracom Components, we became Exir Telecom in 2008
after becoming part of the Exir Group. Though the brand names are
new, our products continue to be built with experience and tradition
stretching back to the first RF infrastructures to be built in Sweden.
Today our position on the worldwide market continues to grow stronger
thanks to the extensive production knowledge and manufacturing ca-
pacity available to us as part of the Exir / Arkivator Group now owned
by the LEAX Group.
Where new ideas come firstLEAX Arkivator telecom invests heavily in time and costs the develop-
ment of new ideas and products that will improve the quality and reliabil-
ity of the world’s telecom systems. An excellent example is the first ever
easy-to-use, single piece connector that we introduced back in 1998, an
innovation that revolutionized the market. By studying problems on-site
together with installers, our experienced R&D engineers excel at develop-
ing products that simplify installation, improve performance and enhance
overall system reliability.
Our PhilosophyModern communication places great demands on the systems that pro-
cess the information being exchanged throughout the world. It goes
without saying that these systems must be built with reliable products.
When developing new technology it is of the utmost importance to un-
derstand how this technology will be integrated into our everyday lives.
And to understand this, we must be close to the people who use it. It is
from this perspective that we view evolving technologies. We stay close
to our customers, the universities, the technicians using our products,
and to those using our customers’ own innovations on a daily basis. Only
with a clear understanding of the ultimate aim of the technology can we
build the finest quality products available.
Trusted around the worldAt LEAX Arkivator Telecom we work together with major international
operators, system suppliers and cable manufacturers who have used our
products ever since the telecom boom. These companies trust the per-
formance our products deliver, and we are dedicated to maintaining their
confidence while creating new, high quality products. The single piece
connector and our market leading built-in weatherproofing system are
examples of designs that save telecom customers money while provid-
ing long-term system stability.
Leax Arkivator Telecom
Introduction and
General Information
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
4/1135Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Having been around since long before the dawn of modern tele-
communications, The Exir Telecom brand offers the benefit of far-
reaching experience and in-depth knowledge.
As a customer you can benefit from our knowledge of sourcing
and manufacturing within the telecoms sector. LEAX Arkivator
Telecom offers the chance to establish a channel for service, good
quality and cost saving solutions.
Unbeatable quality and advantages
with Exir Telecom branded components.
Unrivalled Industry knowledge with
LEAX Arkivator Telecom products.
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
5/1136 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
AT CABLE ENTRY
O-ring at cable entry prevents water leakage between
connector and plastic cable jacket.
BETWEEN CONNECTOR’S FRONT AND BACK PIECES
O-ring to prevent moisture migration during installation.
AROUND OUTER COPPER TUBE
Double O-rings prevent leakage between connector
and outer conductor.
INSIDE THE CONNECTOR HEAD
A leaking antenna can cause damage throughout the
system. O-rings at the connector head stop such
water leakage and protect the rest of the system
from further damage.
SILVER-PLATED CONTACT SURFACES
All contact surfaces are silver-plated to achieve
maximum conductivity.
VIBRATION RESISTANT CONSTRUCTION
The double O-rings sealing the outer conductor
provide added stability to protect against the
wear otherwise caused by cable vibrations.
HIGH CONTACT PRESSURE ON OUTER CONDUCTOR
The connector’s mechanical construction allows great
pressure to be applied to the area of contact with the
cable’s outer conductor when tightened around the
cable. A specially designed slot keeps the outer
conductor of the cable in place.
Design Features for Preventing Intermodulation
O-Ring Sealing for Guaranteed Water Protection
1
1 3
2 4
3
2
31 2
1 432
Reliable Connector Design
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
6/1137Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
HOW WE STOP WATER FROM GETTING IN With simpler products there is a sizeable risk that water and moisture will
enter into the antenna system. This can occur in various ways, the most
likely of which being through poorly sealed connectors, jumper cables or
grounding kits.
External sealants do not protect against moisture that migrates within
the feeder system. Water that collects in antenna panels or amplifiers
can travel down through the system if the connector interface is not
waterproof. Should a crack or hole appear in the feeder cable’s plastic
jacket, water will enter and travel along the outer conductor to nearby
connectors. Our built-in O-ring system prevents migration of this kind
from occurring inside antenna lines.
FROM THE COLDEST TO THE WARMESTCLIMATIC CONDITIONS
Exir Telecom branded products are developed to withstand all climatic
conditions. They have been designed primarily for the harsh Scandina-
vian climate, made to function in the freezing cold of near Arctic winters.
Our products have been tested for performance in a variety of extreme
climatic conditions, from the coldest to the warmest temperatures and
at various humidity levels. They are also proven to be dust-tight and able
to withstand the pressure of desert installation.
Products branded Exir Telecom are designed to operate problem-free
for a minimum of 25 years without any maintenance or any external
sealing. Our products have built-in weather protection consisting of
O-ringsmade of EPDM. These O-rings feature completely seamless
surfaces, superior workability of the sealing under extreme climatic
actions and very good resistance to climatic changes, ozone and UV-
radiation. O-rings of this type are used in the most demanding and
highly critical applications including nuclear power plants, military
uses and various medical equipment.
As our products require no external sealing whatsoever, you will never
have to worry about the unnecessary cost, time-consumption and an-
noyance of taping ever again.
EXCEEDS IP 68The International Standards IP Protection Classification established by
IEC (International Electrotechnical Commission) provides a system for
specifying enclosures of electrical equipment on the basis of the de-
gree of protection required. In order to be awarded IP68 classification
a product must be able to withstand a water pressure of 0.1 bar for 30
minutes. This corresponds to a depth one metre of water.
Exir Telecom’s products for exposed situations have been successfully
tested to withstand 2.5 bar. This means that they can safely operate at
depths of 25 metres under water, which far exceeds the requirements of
the international IP68 standard.
SNOW AND ICE
HUMIDITY AND HEAVY RAIN
DUST AND SAND STORMS
SALT WATER AND STRONG WINDS
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
7/1138 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Keeping your workforce up to date with
the rapid advancements in today’s
mobile telephone technology requires a
commitment to continuous training.
But can you afford the time it takes for
installers to attend training courses
when there are deadlines to be met?
LEAX Arkivator Telecom recognises these pressures, which is why we have developed
a series of flexible, on-site training courses designed to fit around your work schedule
- not ours.
This increasingly popular training option minimises ’lost’ time travelling to an off-site
venue, and allows installers to conveniently update their skills at their place of work even
if the network is being constructed at several sites simultaneously. A typical connector
installation course lasts half a day and can accommodate up to eight participants.
Our on-site training scheme is actually a series of related courses which focus on
the practical aspects of working with connectors and cables. This is a vitally impor-
tant area, as incorrectly installed connectors can result in major power dissipation.
In simple terms, doing the job right the first time results in the highest level of cost
efficiency in the long run.
HANDS-ON TRAINING FOR EVERYONEAll of our instructors have extensive ’hands-on’ experience working with mobile tele-
phony networks in a variety of situations. This means they are capable of answering
questions on both a theoretical and practical level.
During our Connector Installation Course all participants are given the opportunity to
install each of the connector types available in our program. Our qualified instructors are
on hand to answer questions and to lend a helping hand when needed. They also check
each installation to ensure that it meets the required standards of workmanship.
All participants receive a personalised certificate of achievement upon successful
completion of our courses.
LEARN MORE AT LEAX ARKIVATOR TELECOM
LEAX Arkivator Telecom also holds advanced, 5-day courses geared primarily to tech-
nical supervisors, purchasers and project managers.
EXAMPLES OFCOURSES
CONNECTORINSTALLATION COURSE
Basic course covering techniquesfor proper connector installation.
INTRODUCTORY COURSE
This course provides introductory
theory and practical training relat-
ing to such areas as planning and
building fully operational antenna
lines for cellular telephony.
ADVANCED COURSE
This course offers an in-depth look
into various aspects of RF as well
as examines essential issues when
planning and building fully opera-
tional antenna lines
For more detailed information
regarding courses, please contact us.
On-site Training
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
8/1139Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
CONNECTORS
Exir Telecom branded connectors offer many built-in advantages, such as an ex-
panding inner conductor for superior electrical performance, longer body construc-
tion for reduced stress on cables, and advanced weather protection features which
completely eliminate the need for putty tape or any other external weatherproofing.
The LEAX range of connectors are also fully tested and suitable for less harsh envi-
ronments and indoor applications. All of our products have been tested in extreme
climatic conditions. Our connectors are fast and easy to install, and are fully compat-
ible with all major cable brands.
Exir branded Connectors
1/2” Flexible Foam Dielectric
1/2” Flexible Foam Dielectric Right Angle
1/2” Foam Dielectric - Tighten Inner Conductor
1/2” Foam Dielectric Contact Springs
1/2” Foam Dielectric Right Angle
7/8” Foam Dielectric - Contact Springs
7/8” Foam Dielectric - Expanding Inner Conductor
1 1/4” Foam Dielectric
1 5/8” Foam Dielectric
Tools for Foam and Superflex Connectors
LEAX branded Connectors
Connector, N Male for RGC8
Connectors, N Male for 3/8” in, FS
Connectors, 1/2” Foam Dielectric
Connectors, 7/8” Foam Dielectric
Adapter
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
9/11310 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Connectors
1/2” Superflexible Foam Dielectric
* During intermodulation measurement attached cables are exposed to shock and vibration.
NM-S012-A0 NF-S012-A0
7 16 M- S01 2-A0 7 16 F- S0 12 -A0
COMMON FOR ALL
CABLE FORMAT 1/2"
CONNECTOR OPERATING
FREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Acome HPL 50-1/2 SF
Andrew FSJ4-50B
Cablewave S-FLC 12
Condumex RF 1/2”-50 SF
Eupen 5092 1/2” Hiflex
Leoni FlexLine 1/2” SNK Cables RFF 1/2"-50
RFS Cellflex SCF12-50J
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 5 - 6 min
WEIGHT 190 g (0.42 lb)
DIAMETER 27 mm (1.06 in)
LENGTH 76 mm (2.99 in)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 25
TOOL KIT CONK-S012-B0
ARTICLE NM-S012-A0 NF-S012-A0 716M-S012-A0 716F-S012-A0
CONNECTOR N male N female DIN 7/16 male DIN 7/16 female
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
IP68-classified and water-pressure proof tested down to 25 m
High quality O-rings on outer conductor and cable jacket ensure
functional integrity even after accidental damage to cable jacket
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
10/11311Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Connectors
1/2” Superflexible Foam Dielectric Right Angle
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
CABLE FORMAT 1/2"
CONNECTOR OPERATING
FREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Acome HPL 50-1/2 SF
Andrew FSJ4-50B
Cablewave S-FLC 12
Condumex RF 1/2”-50 SF
Eupen 5092 1/2” Hiflex
NK Cables RFF 1/2"-50RFS Cellflex SCF12-50J
INTERMODULATION*
2 x 20 W transmitter
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
11/113118 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com Revision B
l i l
l i
i li i l
i l i i i l
l
i i i i
i l i
i i ll i
l
i
Connectors
1/2” Foam Dielectric - Tighten Inner Conductor
* During intermodulation measurement attached cables are exposed to shock and vibration.
ARTICLE 00NM-F012-G1 00NF-F012-G1 716M-F012-G1 716F-F012-G1
CONNECTOR N male N female DIN 7/16 male DIN 7/16 female
DIAMETER 27 mm (1.06 in) 27 mm (1.06 in) 34 mm (1.34 in) 29 mm (1.14 in)
LENGTH 81.5 mm (3.21 in) 79.5 mm (3.13 in) 71 mm (2.79 in) 71 mm (2.79 in)
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
IP68-classified and water-pressure proof tested down to 25 m
No need for amalgamating tape or other external weatherproofing
High quality O-rings on outer conductor and cable jacket ensure
functional integrity even after accidental damage to cable jacket
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
NM-F012-G1 NF-F012-G1
7 16 M-F 01 2- G1 7 16 F- F0 12 -G1
COMMON FOR ALL
CABLE FORMAT 1/2"
CONNECTOR OPERATING
FREQUENCY 0 - 2500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Andrew LDF4-50
NK Cables RFA 1/2” -50
Cellflex LCF 1/2” Cu2Y
RFS LCF 1/2” -50 Cu2Y
Cablewave FLC 12
Eupen 5128
Acome HPL 50- 1/2” flex
Leoni FlexLine 1/2” RCondumex RF 1/2” -50
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 2 - 3 min
WEIGHT 190 g (0.42 lb)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 25
TOOL-KIT CONK-F012-G0 (std.)
CONK-F012-F0 (basic)
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
12/11312 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com Revision B
oam e ectr c- g ten nner on uctor
Connectors
1/2” Foam Dielectric - Contact Springs
* During intermodulation measurement attached cables are exposed to shock and vibration.
ARTICLE 00NM-F012-H1 00NF-F012-H1 716M-F012-H1 716F-F012-H1
CONNECTOR N male N female DIN 7/16 male DIN 7/16 female
DIAMETER 27 mm (1.06 in) NM 27 mm (1.06 in) NF 34 mm (1.34 in) 7/16m 29 mm (1.14 in) 7/16f
LENGTH 68 mm (2.68 in) NM 66 mm (2.60 in) NF 57 mm (2.25 in) 7/16m 55 mm (2.17 in) 7/16f
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
High quality O-rings on outer conductor and cable jacket ensure
functional integrity even after accidental damage to cable jacket
Designed to maintain high pre sure on contact surfaces to reduce
intermodulation
NM-F012-H1 NF-F012-H1
7 16 M-F 01 2- H1 7 16 F- F0 12 -H1
COMMON FOR ALL
CABLE FORMAT 1/2"
CONNECTOR OPERATING
FREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Andrew LDF4-50
NK Cables RFA 1/2” -50
Cellflex LCF 1/2” Cu2Y
RFS LCF 1/2” -50 Cu2Y
Cablewave FLC 12
Eupen 5128
Acome HPL 50- 1/2” flex
Leoni FlexLine 1/2” RCondumex RF 1/2” -50
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 2 - 3 min
WEIGHT 190 g (0.42 lb)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 25
TOOL-KIT CONK-F012-H0 (std.)
CONK-F012-F0 (basic)
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
13/11313Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Connectors
1/2” Foam Dielectric Right Angle
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
High quality O-rings on outer conductor and cable jacket ensure
functional integrity even after accidental damage to cable jacket
Designed to maintain high pre sure on contact surfaces to reduce
intermodulation
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
CABLE FORMAT 1/2"CONNECTOR OPERATINGFREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Andrew LDF4-50
NK Cables RFA 1/2"-50
Cellflex LCF 1/2" Cu2Y
RFS LCF 1/2"-50 Cu2Y
Cablewave FLC 12
Eupen 5128
Acome HPL 50-1/2” flex
Leoni FlexLine 1/2” R
Condumex RF 1/2”-50
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 2 - 3 min
WEIGHT 180 g (0.40 lb)
DIAMETER 25 mm (1.06 in)
LENGTH 60 mm (2.36 in)
WITH 49.5 mm (1.95 in)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 25
TOOL-KIT CONK-F012-G0 (std.)
CONK-F012-F0 (basic)
ARTICLE 00NM-FO12-AI00 716M-F012-AI00
CONNECTOR N male right angle DIN 7/16 male right angle
00NM-FO12-AI00 716M-F012-AI00
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
14/11314 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Connectors
7/8” Foam Dielectric - Contact Springs
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
High quality O-rings on outer conductor and cable jacket ensurefunctional integrity even after accidental damage to cable jacket
Designed to maintain high pre sure on contact surfaces to reduce
intermodulation
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
CABLE FORMAT 7/8"
CONNECTOR OPERATINGFREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Acome HPL 50-7/8” flex
Acome HPL 50-7/8” LA
Acome M5423 7/8 UP
Andrew AVA5-50
Andrew LDF5-50A
Cablewave FLC 78
Cellflex LCF 7/8” Cu2Y
Cellflex LCF78-50JA
Condumex RF 7/8”-50
Eupen 5228
Eupen 5228A EC5-50A
Leoni FlexLine 7/8” R
NK Cables RF 7/8"-50
NK RFA 7/8”Tsvetlit PK50-22-39-C 7/8"R
HANSEN 7/8"
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 2 - 3 min
WEIGHT 180 g (0.40 lb)
DIAMETER 39.5 mm (1.56 in)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 25
TOOL KIT CONK-F078-AJ00
ARTICLE 00NM-F078-AF00 00NF-F078-AF00 716M-F078-AF00 716F-F078-AF00
CONNECTOR N male N female DIN 7/16 male DIN 7/16 female
LENGTH 73 mm (2.87 in) NM 71 mm (2.80 in) NF 62 mm (2.44 in) 7/16m 60 mm (2.36 in) 7/16f
00NM-F078-AF00 00NF-F078-AF00
716M-F078-AF00 716F-F078-AF00
Revision B
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
15/11315Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Connectors
7/8” Foam Dielectric - Expanding Inner Conductor
PRODUCT FEATURES
Reusable
Expanding inner conductor
Auto-flaring for faster installation
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
High quality O-rings on outer conductor and cable jacket ensurefunctional integrity even after accidental damage to cable jacket
Designed to maintain high pre sure on contact surfaces to reduce
intermodulation
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
CABLE FORMAT 7/8"
CONNECTOR OPERATINGFREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Acome HPL 50-7/8” flex
Acome HPL 50-7/8” LA
Acome M5423 7/8 UP
Andrew AVA5-50
Andrew LDF5-50A
Cablewave FLC 78
Cellflex LCF 7/8” Cu2Y
Cellflex LCF78-50JA
Condumex RF 7/8”-50
Eupen 5228
Eupen 5228A EC5-50A
Leoni FlexLine 7/8” R
NK Cables RF 7/8"-50
NK RFA 7/8”Tsvetlit PK50-22-39-C 7/8"R
HANSEN 7/8"
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 2 - 3 min
WEIGHT 180 g (0.40 lb)
DIAMETER 39.5 mm (1.56 in)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 25
TOOL KIT CONK-F078-AJ00
ARTICLE 00NM-F078-AG00 00NF-F078-AG00 716M-F078-AG00 716F-F078-AG00
CONNECTOR N male N female DIN 7/16 male DIN 7/16 female
LENGTH 73 mm (2.87 in) NM 71 mm (2.80 in) NF 62 mm (2.44 in) 7/16m 60 mm (2.36 in) 7/16f
00NM-F078-AG00 00NF-F078-AG00
716M-F078-AG00 716F-F078-AG00
Revision B
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
16/11316 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Connectors
1 1/4” Foam Dielectric
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
High quality O-rings on outer conductor and cable jacket ensure
functional integrity even after accidental damage to cable jacket
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
CABLE FORMAT 1 1/4"
CONNECTOR OPERATINGFREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Acome HPL 50-1 1/4 flex
Andrew LDF6-50
Cablewave FLC 114
Cellflex LCF 1 1/4” Cu2Y
Condumex RF 1 1/4”-50
Eupen 5328
Eupen Hiflex EC6-50-HF
Leoni FlexLine 1 1/4” RNK Cables RFA 1 1/4"-50
RFS LCFS114-50JA
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 3 - 4 min
WEIGHT 700 g (1.54 lb)
DIAMETER 51 mm (2 in)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 20
TOOL KIT CONK-F114-AB00
ARTICLE 00NM-F114-AD00 00NF-F114-AD00 716M-F114-AD00 716F-F114-AD00
CONNECTOR N male N female DIN 7/16 male DIN 7/16 female
LENGTH 110 mm (4.33 in) NM 108 mm (4.25 in) Nf 98 mm (3.86 in) 7/16m 97 mm (3.82 in) 7/16f
00NM-F114-AD00 00NF-F114-AD00
716M-F114-AD00 716F-F114-AD00
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
17/11317Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Connectors
1 5/8” Foam Dielectric
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
High quality O-rings on outer conductor and cable jacket ensure
functional integrity even after accidental damage to cable jacket
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
CABLE FORMAT 1 5/8"
CONNECTOR OPERATINGFREQUENCY 0 - 7500 MHz
VSWR / RETURN LOSS
0 - 2000 MHz 1.036 / -35 dB
0 - 2500 MHz 1.065 / -30 dB
CABLE COMPATIBILITY Acome HPL 50-158 flex
Andrew AVA7-50
Andrew LDF7-50A
Cablewave FLC 158
Cellflex LCF 1 5/8" Cu2Y
Condumex RF 1 5/8”-50
Leoni FlexLine 1 5/8” RNK Cables RFA 1 5/8"-50
RFS LCF158-50JA
INTERMODULATION*
2 x 20 W transmitter < -156 dBc
CONNECTING TIME 3 - 4 min
WEIGHT 1100 g (2.42 lb)
DIAMETER 65 mm (2.48 in)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 10
TOOL KIT CONK-F158-AC00
ARTICLE 00NM-F158-AD00 00NF-F158-AD00 716M-F158-AD00 716F-F158-AD00
CONNECTOR N male N female DIN 7/16 male DIN 7/16 female
LENGTH 138 mm (5.43 in) NM 135 mm (5.32 in) NF 125 mm (4.92 in) 7/16m 124 mm (4.88 in) 7/16f
00NM-F158-AD00 00NF-F158-AD00
716M-F158-AD00 716F-F158-AD00
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
18/11318 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
PRODUCT PROFILE
The Exir telecom branded tool kits are designed to enable fast instal-
lation of our connectors. Tools can be ordered separately or in kits. All
connectors and tool kits are delivered with illustrated mounting instruc-
tions. We also offer courses in connector installation.
Cable Preparation Tools
for Cable Connectors
ARTICLE KIT-BAG CONTENTS CONNECTORSCONK-S012-B0 Cable peeler, cable holders, inner conductor tightener (with torque) and flaring tool, open
wrenches, wrench for N and DIN 7/16, silicone gasket protector, N to DIN 7/16 adapter, brush.
xxxx-S012-A0
xxxx-716M-S012-B0
CONK-F012-G0Standard Cable peeler, cable holders, inner conductor tightener (with torque) and flaring tool,
open wrenches, wrench for N and DIN 7/16, N to DIN 7/16 adapter, brush.
xxxx-F012-G1
xxxx-F012-AH00
xxxx-F012-AI00
CONK-F012-H0Standard Cable peeler, cable holders, flaring tool, open wrenches, wrench for N and DIN 7/16, brush. xxxx-F012-H1
CONK-F012-F0Basic
Cable peeler, inner conductor tightener, N to DIN 7/16 adapter.
xxxx-F012-G1
xxxx-F012-H1
xxxx-F012-AH00
xxxx-F012-AI00
CONK-F078-AJ00Standard Cable peeler, cable holders, open wrenches, wrench for N and DIN 7/16, brush,
razor blades, inner conductor tightener 7/16, N to DIN 7/16 adapter.
xxxx-F078-AE02
xxxx-F078-AF00
xxxx-F078-AG00
CONK-F078-G0Basic
Cable peeler, inner conductor tightener, N to DIN 7/16 adapter.
xxxx-F078-AE02xxxx-F078-AF00
xxxx-F078-AG00
CONK-F114-AB00 Cable peeler, cable holders, hook spanners, wrench for N and DIN 7/16, brush, cutting jig. xxxx-F114-AD00
CONK-F158-AC00 Cable peeler, cable holders, hook spanners, wrench for N and DIN 7/16, brush, cutting jig. xxxx-F158-AD00
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
19/11319Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Tools
Tools for Foam and Superflex Connectors
CABLE PEELER
PEEL-S012-B0 1/2” flexible
PEEL-F012-F0 1/2”
PEEL-F078-G0 7/8”
PEEL-F114-A0 1 1/4”
PEEL-F158-A0 1 5/8”
OPEN WRENCHES
OCST-S012-A1 1/2” flexible
OCST-F012-H0 1/2” H1
OCST-S012-A1 1/2” G1OCST-F078-B0 7/8”
INNER CONDUCTORSTRAINERS AND FLARING TOOLS
ISFL-S012-B0 1/2” flexible
FLAT-F012-H0 1/2” H1
ISFL-F012-B0 1/2” G1
ICST-7160-C0* 7/16 without torque
SPANNERS
014-51510 1 1/4” and 1 5/8”
CABLE HOLDERS
CABH-0012-A1 1/2” flexible
CABH-F012-A1 1/2”
CABH-0078-A1 7/8”
CABH-0114-A1 1 1/4”
CABH-0158-A1 1 5/8”
WRENCH
OCST-N716-A1 N and DIN 7/16”
ADAPTER
ICST-000N-A1 N to DIN 7/16”
SILICONE GASKET PROTECTOR
CONT-S012-A1 1/2” flexible
SILICONE GREASE
014-54502 Silicone grease
BRUSH
014-54500 Plastic brush
RAZOR BLADES
014-54503 Big for 7/8”10 pieces
014-54504 Small for
1/2”, 1 1/4”, 1 5/8”
CUTTING JIGS
CJIG-F114-A1 1 1/4”
CJIG-F158-A1 1 5/8”
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
20/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com22
Connectors
N Male for RGC8
COMMON FOR ALL 716M-RGC8-BA00
IMPEDANCE 50 Ohm
INSERTION LOSS ≤ 0.05×√F(GHz) dB
VSWR / RETURN LOSS
824 - 960 MHz ≤ -24.3 dB (1.13)
1710 - 2690 MHz ≤ -23.1 dB (1.15)
INTERMODULATION
3rd order < -155 dBc (112 dBm)
3rd order test method Two +43 dBm Carriers
OPERATING TEMPERATURE -55 °C to +85 °C
CONTACT ATTACHMENT
Outer Crimp
Inner Solder
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
21/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com 23
Connectors
N Male for 3/8” in, FS
COMMON FOR ALL 716M-F038-BA00
CABLE FORMAT 50 Ohm
IMPEDANCE 3/8”
INSERTION LOSS ≤ 0.05×√F(GHz) dB
VSWR / RETURN LOSS
824 - 960 MHz ≤ -28.3 dB (1.08)
1710 - 2690 MHz ≤ -26.5 dB (1.10)
INTERMODULATION
3rd order < -155 dBc (112 dBm)
3rd order test method Two +43 dBm Carriers
OPERATING TEMPERATURE -55 °C to +85 °C
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
22/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com20
Connectors
1/2” Foam Dielectric
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
High quality O-rings
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
COMMON FOR ALL
CABLE FORMAT 1/2"
VSWR / RETURN LOSS
0 - 2700 MHz 1.10 / -26.5 dB
CABLE COMPATIBILITY Andrew LDF4-50
NK Cables RFA 1/2"-50
Cellflex LCF 1/2" Cu2Y
RFS LCF 1/2"-50 Cu2Y
Cablewave FLC 12
Eupen 5128
Acome HPL 50-1/2” flex
Leoni FlexLine 1/2” R
Condumex RF 1/2”-50
INTERMODULATION*
2 x 20 W transmitter < -155 dBc
CONNECTING TIME 3 - 4 min
DIAMETER
OPERATING TEMP. -55 °C to +80 °C
ARTICLE 00NM-F012-BA00 00NM-F012-BA00 716M-F012-BA00 716F-F012-BA00
CONNECTOR N male N female DIN 7/16 male DIN 7/16 femaleLENGTH ??? mm (in) ??? mm (in) 50 mm (1.97 in) ?? (?? in)
WEIGHT ??? mm (in) ??? mm (in) 118 g (0.26 lb) 104 g (0.23 lb)
Revision A
* During intermodulation measurement attached cables are exposed to shock and vibration.
00NM-F012-BA00 00NF-F012-BA00
716M-F012-BA00 716F-F012-BA00
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
23/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com 21Revision A
Connectors
7/8” Foam Dielectric
PRODUCT FEATURES
Reusable
Auto-flaring for faster installation
High quality O-rings
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
COMMON FOR ALLCABLE FORMAT 7/8"
VSWR / RETURN LOSS
0 - 2700 MHz 1.10 / -26.5 dB
CABLE COMPATIBILITY Acome HPL 50-7/8” flex
Acome HPL 50-7/8” LA
Acome M5423 7/8 UP
Andrew AVA5-50
Andrew LDF5-50A
Cablewave FLC 78
Cellflex LCF 7/8” Cu2Y
Cellflex LCF78-50JA
Condumex RF 7/8”-50
Eupen 5228
Eupen 5228A EC5-50A
Leoni FlexLine 7/8” R
NK Cables RF 7/8"-50
NK RFA 7/8”
Tsvetlit PK50-22-39-C 7/8"R
HANSEN 7/8"
INTERMODULATION*
2 x 20 W transmitter < -155 dBc
CONNECTING TIME 3 - 4 min
DIAMETER 35 mm (1.38 in)
OPERATING TEMP. -55 °C to +80 °C
ARTICLE 00NM-F078-BA00 00NM-F078-BA00 716M-F078-BA00 716F-F078-BA00
CONNECTOR N male N female DIN 7/16 male DIN 7/16 femaleLENGTH ??? ??? 57 mm (2.24 in)
WEIGHT ??? ??? 195 g (0.43 lb)
* During intermodulation measurement attached cables are exposed to shock and vibration.
00NM-F078-BA00 00NF-F078-BA00
716M-F078-BA00 716F-F078-BA00
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
24/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com24
Adapter
Revision A
ELECTRICAL CHARACTERISTICS
FREQUENCY RANGE 824 - 960 & 1710 - 2690 MHz
IMPEDANCE 50 Ohm
INSERTION LOSS
0 - 3000 MHz < 0.1 dB
RETURN LOSS/VSWR
0 - 3000 MHz < 32 dB (1.05)
INTERMODULATION
3rd order ≤ -155 dBc (112 dBm) @ 910 MHz
3rd order test method Two +43 dBm Carriers
OPERATING TEMPERATURE -40 °C to +85 °C
SEALING O-ring
PLATING Silver-plated
ARTICLE NO
7/16M-7/16M 716M-716M-BA00
7/16F-7/16F 716F-716F-BA00
7/16M-7/16F 716M-716F-BA00
7/16M-NF 716M-00NF-BA00
7/16M-NM 716M-00NM-BA00
7/16F-NF 716F-00NF-BA00
7/16F-NM 716F-00NF-BA00
NF-NF 00NF-00NF-BA00
NM-NM 00NM-00NM-BA00
NF-NF 00NM-00NF-BA00
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
25/11325Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
FEEDER & JUMPER CABLES
The LEAX branded feeder cable range provides a very good standard feeder cable
solution. These cables are cased in black polyethylene and as usual very well posi-
tioned price wise.
Exir Telecom branded jumper cables are water-pressure proof down to 25 meters,
which is equivalent to a pressure of 2.5 bar and far exceeds the requirements for IP68-
classification. Consequently there is no need for tape or any other external weather-
proofing. All jumper cables are available in any length and offer a generous bending
radius. Every cable is tested and can as an option come individually labeled with the re-
sults to identify its measured return loss performance within the 0-3000 MHz range.
LEAX branded Feeder Cables
RG8 Link Cable
Feeder Cable, Foam Coaxial Cable, 3/8” in, Black PE Jacket
Feeder Cable, Foam Coaxial Cable, 1/2” in, Black PE Jacket
Feeder Cable, Foam Coaxial Cable, 7/8” in, Black PE Jacket
Exir branded Jumper Cables
1/2” Foam Dielectric Cable
1/2” Superflexible Foam Dielectric Cable
1/2” Superflexible Foam Dielectric Cable - Angle Connector
LEAX branded Jumper Cables
1/2” Superflexible Foam Dielectric Cable
1/2” Superflexible Foam Dielectric Cable - Angle Connector
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
26/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com 29
PRODUCT STRUCTURE
DESIGNATION MATERIAL DIAMETER (mm)
1 Inner Conductor Copper clad aluminium 2.74±0.025
2 Dielectric Foam Polyethylene 7.24±0.13
3 Outer Conductor Bonded aluminum foil --
3 Outer Conductor Tinned copper wire braid Nom. 8.13
4 Jacket Blac polyethylene, PE 10.16±0.2
RG8 Link Cable
ELECTRICAL FEED-F0R8-AA00
IMPEDANCE 50 Ohm
RETURN LOSS/VSWR
5 - 3000 MHz ≤ 1.20
MAX OPERATING VOLTAGE 3.0
VELOCITY 85%
CAPACITANCE Nom. 78
INSULATION RESISTANCE 5000
SCREENING EFFECTIVENESS 90
ENVIRONMENTAL
OPERATING TEMPERATURE -40°C ~ +80°C
BENDING RADIUS ONCE 25
REPEATED BENDING RADIUS 76
FLEXIBLE APPLICATION RADIUS 102
COMPLIANCY RoHS
ATTENUATION @ 20°C AND SEA LEVEL
FREQUENCY (MHZ) ATTENUATION (DB/100M)
140 6.0
350 9.0
900 15.0
1800 20.0
1900 21.0
2500 25.0
3000 28.0
4000 34.0
5000 38.0
6000 42.0
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
27/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com 27
Feeder Cable
Foam Coaxial Cable, 3/8” in, Black PE Jacket
ELECTRICAL FEED-F038-AA00
IMPEDANCE 50 Ohm
RETURN LOSS
824 - 960 MHz ≤ -24.3 (1.13)
1710 - 2170 MHz ≤ -24.3 (1.13)
MAX OPERATING FREQUENCY 13000 MHz
VELOCITY 88 %
CAPACITANCE 76 pF/m
PASSIVE INTER-MODULATION ≤ -155 dBc @ 2 x 20W (43dBm)
RF PEAK POWER RATING ≥ 15.6 KW
RF PEAK VOLTAGE ≥ 4000 V
JACKET SPARK TEST (RMS) ≥ 5000 V
DIELECTRIC RESISTANCE ≥ 5000 MOhm / Km
MECHANICAL
MIN BEND RADIUS, MULTIPLE BENDS 95 mm
MIN BEND RADIUS, SINGLE BEND 40 mm
BENDING MOMENT 1.9 Nm
TENSILE STRENGTH ≥ 1100 N
ENVIRONMENTAL
OPERATING TEMPERATURE -55°C ~ +85°C
INSTALLATION TEMPERATURE -40°C ~ +60°C
STORAGE TEMPERATURE -70°C ~ +85°C
RELATIVE HUMIDITY 0 ~ 95%
COMPLIANCY ROHS 2002/95/EC
ATTENUATION AND AVERAGE POWER
FREQUENCY (MHZ) ATTENUATION (DB/100M) AVERAGE POWER (KW)
450 MHZ 7.52 1.03
824 MHZ 10.40 0.74
960 MHZ 11.30 0.68
1000 MHZ 11.56 0.67
1800 MHZ 16.00 0.48
2000 MHZ 16.97 0.45
2200 MHZ 17.91 0.43
2500 MHZ 19.26 0.40
2700 MHZ 20.13 0.38
Revision A
PRODUCT STRUCTURE
DESIGNATION MATERIAL DIAMETER (mm)
1 Inner Conductor Copper clad aluminum wire 3.30±0.05
2 Dielectric Physical Foam Polyethylene 8.30±0.20
3 Outer Conductor Corrugated copper tube 9.60±0.25
4 Jacket Black polyethylene, PE 11.20±0.30
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
28/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com26
Feeder Cable
Foam Coaxial Cable, 1/2” in, Black PE Jacket
ELECTRICAL FEED-F012-AA00
IMPEDANCE 50 Ohm
RETURN LOSS
824 - 960 MHz ≤ -24.3 (1.13)
1710 - 2170 MHz ≤ -24.3 (1.13)
MAX OPERATING FREQUENCY 8800 MHz
VELOCITY 88 %
CAPACITANCE 76 pF/m
PASSIVE INTER-MODULATION ≤ -155 dBc @ 2 x 20W (43dBm)
RF PEAK POWER RATING ≥ 40 KW
RF PEAK VOLTAGE ≥ 4000 V
JACKET SPARK TEST (RMS) ≥ 8000 V
DIELECTRIC RESISTANCE ≥ 5000 MOhm / Km
MECHANICAL
MIN BEND RADIUS, MULTIPLE BENDS 125 mm
MIN BEND RADIUS, SINGLE BEND 50 mm
BENDING MOMENT 3.8 Nm
TENSILE STRENGTH ≥ 1100 N
ENVIRONMENTAL
OPERATING TEMPERATURE -55°C ~ +85°C
INSTALLATION TEMPERATURE -40°C ~ +60°C
STORAGE TEMPERATURE -70°C ~ +85°C
RELATIVE HUMIDITY 0 ~ 95%
COMPLIANCY ROHS 2002/95/EC
ATTENUATION AND AVERAGE POWER
FREQUENCY (MHZ) ATTENUATION (DB/100M) AVERAGE POWER (KW)
450 MHZ 4.75 1.61
824 MHZ 6.56 1.16
960 MHZ 7.12 1.07
1000 MHZ 7.28 1.05
1800 MHZ 10.06 0.76
2000 MHZ 10.67 0.72
2200 MHZ 11.25 0.68
2500 MHZ 12.09 0.63
2700 MHZ 12.63 0.60
Revision A
PRODUCT STRUCTURE
DESIGNATION MATERIAL DIAMETER (mm)
1 Inner Conductor Copper clad aluminum wire 4.80±0.03
2 Dielectric Physical Foam Polyethylene 12.20±0.2
3 Outer Conductor Regular corrugated copper tube 13.90±0.25
4 Jacket Black polyethylene, PE 15.70±0.20
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
29/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com28
Feeder Cable
Foam Coaxial Cable, 7/8” in, Black PE Jacket
ELECTRICAL FEED-F078-AA00
IMPEDANCE 50 Ohm
RETURN LOSS
824 - 960 MHz ≤ -24.3 (1.13)
1710 - 2170 MHz ≤ -24.3 (1.13)
MAX OPERATING FREQUENCY 5000 MHz
VELOCITY 88 %
CAPACITANCE 76 pF/m
PASSIVE INTER-MODULATION ≤ -155 dBc @ 2 x 20W (43dBm)
RF PEAK POWER RATING ≥ 91 KW
RF PEAK VOLTAGE ≥ 6000 V
JACKET SPARK TEST (RMS) ≥ 8000 V
DIELECTRIC RESISTENCE ≥ 5000 MOhm / KM
MECHANICAL
MIN BEND RADIUS, MULTIPLE BENDS 250 mm
MIN BEND RADIUS, SINGLE BEND 125 mm
BENDING MOMENT 19.0 Nm
TENSILE STRENGTH ≥ 1450 N
ENVIRONMENTAL
OPERATING TEMPERATURE -55°C ~ +85°C
INSTALLATION TEMPERATURE -40°C ~ +60°C
STORAGE TEMPERATURE -70°C ~ +85°C
RELATIVE HUMIDITY 0 ~ 95%
COMPLIANCY ROHS 2002/95/EC
ATTENUATION AND AVERAGE POWER
FREQUENCY (MHZ) ATTENUATION (DB/100M) AVERAGE POWER (KW)
450 MHZ 2.44 3.44
824 MHZ 3.38 2.49
960 MHZ 3.67 2.29
1000 MHZ 3.76 2.24
1800 MHZ 5.21 1.61
2000 MHZ 5.53 1.52
2200 MHZ 5.83 1.44
2500 MHZ 6.27 1.34
2700 MHZ 6.55 1.28
Revision A
PRODUCT STRUCTURE
DESIGNATION MATERIAL DIAMETER (mm)
1 Inner Conductor Copper tube 8.90±0.10
2 Dielectric Physical Foam Polyethylene 22.50±0.40
3 Outer Conductor Regular corrugated copper tube 24.90±0.30
4 Jacket Black polyethylene, PE 27.30±0.20
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
30/11330 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Jumper Cables
1/2” Foam Dielectric Cable
PRODUCT FEATURES
10-year comprehensive warranty
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
Each cable individually tested an labelled with return loss graph,
0 - 2200 MHz
* Typical return loss connecto r.** During intermodulation measurement attached cables are exposed to shock and vibration.
*** XX is the length of the cable. For example: AB05=0.5 m, AB10=1.0 m.
DIN 7/16 TO DIN 7/16
ARTICLE CONNECTORS
JBB0-F012-ABxx*** DIN 7/16 male to DIN 7/16 male
JAB0-F012-ABxx DIN 7/16 female to DIN 7/16 male
DIN 7/16 TO N
ARTICLE CONNECTORS
JBD0-F012-ABxx DIN 7/16 male to N male
JAD0-F012-ABxx DIN 7/16 female to N male
N TO N
ARTICLE CONNECTORS
JDD0-F012-ABxx N male to N male
JCD0-F012-ABxx N female to N male
COMMON FOR ALL
CABLE TYPE 1/2"
FREQUENCY RANGE 0 - 5000 MHz
VSWR / RETURN LOSS
0 - 1000 MHz 1.08 / -28 dB (-35 dB)*
1000 - 2200 MHz 1.10 / -26 dB (-35 dB)*
INTERMODULATION**
2 x 20 W transmitter < -156 dBc
OPERATING TEMPERATURE -55 °C to +80 °C
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
31/11331Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Jumper Cables
1/2” Superflexible Foam Dielectric Cable
PRODUCT FEATURES
Each cable individually tested
10-year comprehensive warranty
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
Designed to maintain high pressure on contact surfacces to reduce
intermodulation
* Typical performance for jumpers of ordinary length.
** During intermodulation measurement, cables were exposed to shock and vibration.
*** XX is the length of the cable. For example: AC05=0.5 m, AC10=1.0 m.
COMMON FOR ALL
CABLE TYPE 1/2" Superflex
FREQUENCY RANGE 0 - 5000 MHz
VSWR / RETURN LOSS
0 - 2700 MHz 1.12 / -25 dB*
INTERMODULATION**
2 x 20 W transmitter < -160 dBc
OPERATING TEMPERATURE -55 °C to +80 °C
DIN 7/16 TO DIN 7/16
ARTICLE CONNECTORS
JBB0-S012-ACxx*** DIN 7/16 male to DIN 7/16 male
JAB0-S012-ACxx DIN 7/16 female to DIN 7/16 male
DIN 7/16 TO N
ARTICLE CONNECTORS
JBD0-S012-ACxx DIN 7/16 male to N male
JBC0-S012-ACxx DIN 7/16 male to N female
N TO N
ARTICLE CONNECTORS
JDD0-S012-ACxx N male to N male
JCC0-S012-ACxx N female to N female
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
32/11332 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Jumper Cables
1/2” Superflexible Foam Dielectric Cable- Angle Connector Angle Connector
PRODUCT FEATURES
Each cable individually tested
10-year comprehensive warranty
Outstanding VSWR and IM values
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
COMMON FOR ALL
CABLE TYPE 1/2" Superflex
FREQUENCY RANGE 0 - 5000 MHz
VSWR / RETURN LOSS
0 - 2700 MHz 1.12 / -25 dB*
INTERMODULATION**
2 x 20 W transmitter < -160 dBc
OPERATING TEMPERATURE -55 °C to +80 °C
* Typical performance for jumpers of ordinary length.
** During intermodulation measurement, cables were exposed to shock and vibration.
*** XX is the length of the cable. For example: AC05=0.5 m, AC10=1.0 m.
1/2” Superflexible Foam Dielectric Cable - Angle Connector
Revision C
DIN 7/16 TO DIN 7/16
ARTICLE CONNECTORS
JBA1-S012-ACxx*** DIN 7/16 male angle to DIN 7/16 female
JBB1-S012-ACxx DIN 7/16 male angle to DIN 7/16 male
DIN 7/16 TO N
ARTICLE CONNECTORS
JBC1-S012-ACxx DIN 7/16 male angle to N female
JBD1-S012-ACxx DIN 7/16 male angle to N male
JDA1-S012-ACxx DIN 7/16 female to N male angle
JDB1-S012-ACxx DIN 7/16 male to N male angle
N TO N
ARTICLE CONNECTORS
JDC1-S012-ACxx N male angle to N female
JDD1-S012-ACxx N male angle to N male
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
33/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com34
Jumper Cables
1/2” Superflexible Foam Dielectric Cable
* Typical return loss connecto r.** During intermodulation measurement attached cables are exposed to shock and vibration.
*** XX is the length of the cable. For example: BA05=0.5 m, BA10=1.0 m.
Revision C
PRODUCT FEATURES
Outstanding VSWR and IM values
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
COMMON FOR ALL
CABLE TYPE 1/2" Superflex
FREQUENCY RANGE 0 - 5000 MHz
VSWR / RETURN LOSS
0 - 2700 MHz 1.12 / -25 dB*
INTERMODULATION**
2 x 20 W transmitter < -160 dBc
OPERATING TEMPERATURE -55 °C to +80 °C
1/2” Superflexible Foam Dielectric Cable
DIN 7/16 TO DIN 7/16
ARTICLE CONNECTORS
JBB0-S012-BAxx*** DIN 7/16 male to DIN 7/16 male
JAB0-S012-BAxx DIN 7/16 female to DIN 7/16 male
DIN 7/16 TO N
ARTICLE CONNECTORS
JBD0-S012-BAxx DIN 7/16 male to N male
JBC0-S012-BAxx DIN 7/16 male to N female
N TO N
ARTICLE CONNECTORS
JDD0-S012-BAxx N male to N male
JCC0-S012-BAxx N female to N female
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
34/113Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com 33
Jumper Cables
1/2” Superflexible Foam Dielectric Cable- Angle Connector Angle Connector
PRODUCT FEATURES
Outstanding VSWR and IM values
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
COMMON FOR ALL
CABLE TYPE 1/2" Superflex
FREQUENCY RANGE 0 - 5000 MHz
VSWR / RETURN LOSS
0 - 2700 MHz 1.12 / -25 dB*
INTERMODULATION**
2 x 20 W transmitter < -160 dBc
OPERATING TEMPERATURE -55 °C to +80 °C
* Typical performance for jumpers of ordinary length.
** During intermodulation measurement, cables were exposed to shock and vibration.
*** XX is the length of the cable. For example: BA05=0.5 m, BA10=1.0 m.
Revision C
1/2” Superflexible Foam Dielectric Cable - Angle Connector
DIN 7/16 TO DIN 7/16
ARTICLE CONNECTORS
JBA1-S012-BAxx*** DIN 7/16 male angle to DIN 7/16 female JBB1-S012-BAxx DIN 7/16 male angle to DIN 7/16 male
DIN 7/16 TO N
ARTICLE CONNECTORS
JBC1-S012-BAxx DIN 7/16 male angle to N female
JBD1-S012-BAxx DIN 7/16 male angle to N male
JDA1-S012-BAxx DIN 7/16 female to N male angle
JDB1-S012-BAxx DIN 7/16 male to N male angle
N TO N
ARTICLE CONNECTORS
JDC1-S012-BAxx N male angle to N female
JDD1-S012-BAxx N male angle to N male
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
35/11335Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
EMP & GROUNDING
Exir Telecom branded EMP protectors and grounding kits protect telecom sites
from lightning strikes and surges that damage equipment and cause system
breakdown. The products have been tested with a lightning pulse of 50 kA,
10/350 ms, and have passed without sustaining any damage or loss of perfor-
mance.
Thanks to our O-ring protection system, the grounding kits are water-pressure
proof down to 25 metres, which is equivalent to a pressure of 2.5 bar and far ex-
ceeds the requirements for IP68-classification. Consequently there is no need
for tape or any other external weatherproofing.
Exir branded EMP & Grounding
EMP Protectors, Triple Band
EMP Protectors, Gas discharge tube, DC-3000 MHz
EMP Protectors, Short circuit, 750 - 3000 MHz
Grounding Kits, Lightning Protection for Foam Dielectric Cables
Tool Kits
Grounding Kit, Lightning Protection for 1/2” Superflexible Foam Dielectric Cable
External Grounding Kits - Lightning Protection for Connectors
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
36/11336 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
EMP Protectors
Triple Band
PRODUCT FEATURES
10-year comprehensive warranty
Designed to maintain high pressure oncontact surfaces to reduce
intermodulation
IP68-classified and water-pressure proof tested down to 25 m
No need for amalgamating tape or other external weatherproofing
MOUNTING BRACKET
The EMP protector is available with
grounding bracket for mounting di-
rectly on grounding bars on request.
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
FREQUENCY RANGE 806 - 960 MHz
1710 - 2170 MHz
VSWR / RETURN LOSS
806 - 890 MHz 1.17 / -22 dB
890 - 960 MHz 1.12 / -25 dB
1710 - 2200 MHz 1.12 / -25 dB
INTERMODULATION*
2 x 20 W Tx < -156 dBc
IMPEDANCE 50 ohmSURGE CURRENT 100 kA
HANDLING CAPABILITY (test pulse 8/20 µs)
ENERGY test pulse 4 kV 1.2/50 µs
test pulse 2 kA 8/20 µs
WEIGHT 560 g (1.23 lb)
DIMENSIONS 30 x 40 x 110 mm
H x W x D (1.17 x 1.56 x 4.29 in)
OPERATING TEMP. -55 °C to +80 °C
PIECES IN BOX 25
ARTICLE EMPP-0822-AA00 EMPP-0822-AB00 EMPP-0822-AC00 EMPP-0822-AD00
CONNECTORS DIN 7/16 female to RX/TX - DIN 7/16 male to RX/TX - N female to RX/TX - N male to RX/TX -
DIN 7/16 male to antenna DIN 7/16 female to antenna N male to antenna N female to antenna
INPUT POWER 600 W 600 W 150 W 150 W
EMP Protectors, Triple Band
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
37/11337Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
EMP Protectors
Gas discharge tube, DC - 3000 MHz
COMMON FOR ALL
FREQUENCY RANGE DC - 3000 MHz
VSWR / RETURN LOSS 1.22 / -20 dB
IMPEDANCE 50 ohm
DISCHARGE VOLTAGE 230 or 90 V*
IMPULSE DISCHARGE CURRENT
1 impulse (8/20 µs) 20 kA
5 impulses (8/20 µs) in 3 min 10 kA
IMPULSE SPARK OVER VOLTAGE
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
38/11338 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
EMP Protectors
Short circuit, 750 - 3000 MHz
PRODUCT FEATURES
Made of silver-plated brass
Protected from both ways
10-year comprehensive warranty
No need for amalgamating tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
Designed to maintain high pressure on contact surfaces to reduce
intermodulation
* During intermodulation measurement attached cables are exposed to shock and vibration.
COMMON FOR ALL
FREQUENCY RANGE 750 - 3000 MHz
VSWR / RETURN LOSS 1.22 / -20 dB
INTERMODULATION*
2 x 20 W Transmitter < -156 dBc
IMPEDANCE 50 ohm
SURGE CURRENT 100 kA
HANDLING CAPABILITY Test pulse 8/20 µs
ENERGY test pulse 4 kV 1.2/50 µs
test pulse 2 kA 8/20 µs
WEIGHT 400 g
DIMENSIONS 113 x 34 x 34 mm
H x W x D (4.44 x 1.33 x 1.33 in)
OPERATING TEMP. -55 °C to +80 °C
ARTICLE EMPP-0830-AK00 EMPP-0830-AM00 EMPP-0830-AL00
CONNECTOR 7/16 f - 7/16 M Nf - Nm 7/16 f - 7/16 f
INPUT POWER 600 W 150 W 600 W
Revision B
EMP Protectors, Short circuit, 750 - 3000 MHz
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
39/11339Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Grounding Kits
Lightning Protection for Foam Dielectric Cables
ARTICLE GROU-F012-AB00 GROU-F078-AB00 GROU-F114-AB00 GROU-F158-AB00
CABLE COMPATIBILITY Andrew LDF4-50 Acome HPL 50-7/8” flex Acome HPL 50-1 1/4 flex Acome HPL 50-158 flex
NK Cables RFA 1/2"-50 Acome HPL 50-7/8” LA Andrew LDF6-50 Andrew AVA7-50
Cellflex LCF 1/2" Cu2Y Acome M5423 7/8 UP Cablewave FLC 114 Andrew LDF7-50A
RFS LCF 1/2"-50 Cu2Y Andrew AVA5-50 Cellflex LCF 1 1/4” Cu2Y Cablewave FLC 158
Cablewave FLC 12 Andrew LDF5-50A Condumex RF 1 1/4”-50 Cellflex LCF 1 5/8" Cu2Y
Eupen 5128 Cablewave FLC 78 Eupen 5328 Condumex RF 1 5/8”-50
Acome HPL 50-1/2” flex Cellflex LCF 7/8” Cu2Y Eupen Hiflex EC6-50-HF Leoni FlexLine 1 5/8” R
Leoni FlexLine 1/2” R Cellflex LCF78-50JA Leoni FlexLine 1 1/4” R NK Cables RFA 1 5/8"-50Condumex RF 1/2”-50 Condumex RF 7/8”-50 NK Cables RFA 1 1/4"-50 RFS LCF158-50JA
Eupen 5228 RFS LCFS114-50JA
Eupen 5228A EC5-50A
Leoni FlexLine 7/8” R
NK Cables RF 7/8"-50
NK RFA 7/8”
Tsvetlit PK50-22-39-C 7/8"R
HANSEN 7/8"
GROUND CONN. Cable clip, M5 Cable clip, M5 Cable clip, M5 Cable clip, M5
DIMENSIONS 50 x 25 x 32 mm 50 x 32 x 43 mm 50 x 43 x 57 mm 52 x 54 x 68 mm
H x W x D (front view) (1.97 x 0.98 x 1.26 in) (1.97 x 1.26 x 1.69 in) (1.97 x 1.69 x 2.24 in) (2.05 x 2.13 x 2.68 in)
CONTACT AREA >25 mm² (0.04 in²) >25 mm² (0.04 in²) >25 mm² (0.04 in²) >25 mm² (0.04 in²)
WEIGHT 242 g (0.53 lb) 306 g (0.66 lb) 424 g (0.94 lb) 556 g (1.23 lb)
CABLE LENGTH 600 mm (23.64 in) 600 mm (23.64 in) 600 mm (23.64 in) 600 mm (23.64 in)
OPERATING TEMP. -55 °C to +80 °C -55 °C to +80 °C -55 °C to +80 °C -55 °C to +80 °C
TOOL KITS CPKI-0000-C0 CPKI-0000-C0 CPKI-0000-C0 CPKI-0000-C0
Grounding Kits, Lightning Protectionfor Foam Dielectric Cables
Revision A
PRODUCT FEATURES
Reusable
Fast and easy installation
Large contact surface area
Fits multiple cable brands
10-year comprehensive warranty
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
PRODUCT PROFILE
Our Exir Telecom branded grounding kits feature an efficient design enabling multiple units
to be mounted very close together. A simple, adjustable construction allows for easy attach-
ment to a wide range of cables from various manufacturers. These grounding kits are reusable
and 100% weatherproof without the need for tape or any other external weatherproofing.
The contact surfaces are designed to closely fit the corrugated surface of the outer con-
ductor, thus avoiding unnecessary pressure. As a result, the effect of grounding on the
VSWR measurement of the antenna line is barely detectable.
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
40/11340 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Tool Kits
Mounting Grounding Kits
PRODUCT PROFILE
The Exir Telecom branded tool kits provide installers all they
need for installing grounding kits quickly and easily. Our ground-
ing devices require only one small opening in the cable jacket in
order to function properly. The opening is made using a hot tip
cutting tool together with a simple template. Fully illustrated
instructions are included with every grounding kit.
The complete tool kit includes a cordless, butane powered
cutting tool, one spare tip and templates. Additional cutting
tools and templates can be ordered separately as needed.
Note: The above photos illustrate the general installation procedure. Please visit www.exirtelecom.com for complete instructions on how toinstall grounding kits from Exir Telecom.
COMPLETE TOOL KIT
ARTICLE CONTENTS
CPKI-0000-C1 Cordless, butane powered cutting tool, spare tip and
templates for 1/2”, 7/8”, 1 1/4” and 1 5/8” cables.
SINGLE TOOLS
ARTICLE CONTENTS
EJIG-F012-A0 Template for 1/2” cable
EJIG-F078-A0 Template for 7/8” cable
GTEM-F114-AA00 Template for 1 1/4” cable
GTEM-F158-AA00 Template for 1 5/8” cable
014-12015 Cordless, butane powered cutting tool with spare tip
1 2 3
4 5 6
Tool Kits
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
41/11341Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Grounding Kit, Lightning Protection for 1/2” Superflexible Foam
Dielectric Cable
Grounding Kit
Lightning Protection for 1/2” Superflexible Foam Dielectric Cable
ARTICLE GROU-S012-AA00
CABLE COMPATIBILITY Acome HPL 50-1/2 SF
Andrew FSJ4-50B
Cablewave S-FLC 12
Condumex RF 1/2”-50 SF
Eupen 5092 1/2” Hiflex
Leoni FlexLine 1/2” S
NK Cables RFF 1/2”-50
RFS Cellflex SCF12-50J
GROUND CONN. Cable clip, M5
CONTACT AREA >20 mm² (0.44 in²)
WEIGHT 200 g (0.44 lb)
DIMENSIONS 18 x 27 x 34 mm
H x W x D (0.71 x 1.06 x 1.34 in)
CABLE LENGTH 600 mm (23.64 in)
OPERATING TEMP. -55 °C to +80 °C
Revision A
PRODUCT FEATURES
Reusable
Fast and easy installation
Large contact surface area
Fits multiple cable brands
10-year comprehensive warranty
PRODUCT PROFILE
Exir Telecom branded grounding kits feature an efficient design enabling
multiple units to be mounted very close together. A simple, adjustable
construction allows for easy attachment to a wide range of cables from
various manufacturers. These grounding kits are reusable.
The contact surfaces are designed to closely fit the corrugated surface
of the outer conductor, thus avoiding unnecessary pressure. As a result,
the effect of grounding on the VSWR measurement of the antenna line
is barely detectable.
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
42/11342 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
External Grounding Kits
Lightning Protection for Connectors
ARTICLE EXGR-F012-AA00 EXGR-F078-AA00 EXGR-F114-AA00 EXGR-F158-AA00
CONNECTOR xxxx-F012-G1 xxxx-F078-AE02 xxxx-F114-AD00 xxxx-F158-AD00
COMPATIBILITY xxxx-F012-H1 xxxx-F078-AF00
xxxx-F078-AG00
CONTACT AREA >25 mm2 (0.04 in2) >25 mm2 (0.04 in2) >25 mm2 (0.04 in2) >25 mm2 (0.04 in2)
CABLE LENGTH 600 mm (23.64 in) 600 mm (23.64 in) 600 mm (23.64 in) 600 mm (23.64 in)
OPERATING TEMP. -55 °C to +80 °C -55 °C to +80 °C -55 °C to +80 °C -55 °C to +80 °C
PIECES IN BOX 50 50 50 50
PRODUCT FEATURES
Reusable
Non-corrosive
Fast and easy installation
Large contact surface area
10-year comprehensive warranty
Made of silver-plated brass and stainless steel
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
PRODUCT PROFILEThe external grounding kit is designed to be mounted around the connector
and to cause the connector itself to function as a grounding device.
This solution is very easy to install and provides extra protection at the
feeder connector.
Revision A
External Grounding Kits
Lightning Protection for Connectors
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
43/11344 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
CABLE CLAMPS
Exir Telecom branded cable clamps make cable installation easier, saving you
valuable time. Moreover, they provide protection from the damage that high
winds inflict upon improperly fastened cables damage that may lead to in-
creased reflection due to mechanical stress. Our cable clamps are manufactured
of corrosion resistant stainless steel and are designed to achieve a perfect dis-
tribution of pressure on cables.
We offer cable clamps for use with flat, round and angle tower members, as well
as for wall attachment. Our clamps are convenient to carry and easy to mount
- features your installers will appreciate.
Exir branded Cable Clamps
Cable Clamps for Flat (1.5 - 23 mm) and Round (8 - 23 mm) Tower Members
Cable Clamps for 40 mm Angle Tower Members
Cable Clamp Single
Cable Clamp Double
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
44/11344 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Cable Clamps for Flat (1.5 - 23 mm) and
Round (8 - 23 mm) Tower Members
Cable Clamps
For Flat (3-25 mm) and Round (8-25 mm) Tower Members
STANDARD CLAMPS
1/2” CABLE
ARTICLE CABLE NO. OF CABLES
CL23-1C012-B0 1/2" 1
CL23-2C012-B0 1/2" 2
CL23-3C012-B0 1/2" 3
CL23-4C012-B0 1/2" 4
CL23-5C012-B0 1/2" 5
7/8” CABLE
ARTICLE CABLE NO. OF CABLES
CL23-1C078-B0 7/8" 1
CL23-2C078-B0 7/8" 2
CL23-3C078-B0 7/8" 3
CL23-4C078-B0 7/8" 4
CL23-5C078-B0 7/8" 5
1 1/4” CABLE
ARTICLE CABLE NO. OF CABLES
CL23-1C114-B0 1 1/4" 1
CL23-2C114-B0 1 1/4" 2
CL23-3C114-B0 1 1/4" 3
1 5/8” CABLE
ARTICLE CABLE NO. OF CABLES
CL23-1C158-B0 1 5/8" 1
CL23-2C158-B0 1 5/8" 2
CL23-3C158-B0 1 5/8" 3
Typical usage examples for clamps.
Revision A
PRODUCT FEATURES
Made of stainless steel and U.V. resistent Fiberglass P.A.
Fast and easy assembly
Secured with wrench or hex key
Various cable dimensions
Supports up to 5 cable runs
No need for adapters or drilling holes
Minimises utilised space on towers, reducing wind load
Protective interlayers safeguard against cable deformation
For use with 3 - 25 mm (0.12 - 1.0 in) flat and 8 - 25 mm
(0.31 - 1.0 in) round members
1x.. 2x.. 3x.. 4x.. 5x..
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
45/11345Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Cable Clamps for 40 mm Angle Tower
Members
Cable Clamps
for 40 mm Angle Tower Members
STANDARD CLAMPS
1/2” CABLE
ARTICLE CABLE NO. OF CABLES
CL40-1C012-B0 1/2" 1
CL40-2C012-B0 1/2" 2
CL40-3C012-B0 1/2" 3
CL40-4C012-B0 1/2" 4
CL40-5C012-B0 1/2" 5
7/8” CABLE
ARTICLE CABLE NO. OF CABLES
CL40-1C078-B0 7/8" 1
CL40-2C078-B0 7/8" 2
CL40-3C078-B0 7/8" 3
CL40-4C078-B0 7/8" 4
CL40-5C078-B0 7/8" 5
1 1/4” CABLE
ARTICLE CABLE NO. OF CABLES
CL40-1C114-B0 1 1/4" 1
CL40-2C114-B0 1 1/4" 2
CL40-3C114-B0 1 1/4" 3
1 5/8” CABLE
ARTICLE CABLE NO. OF CABLES
CL40-1C158-B0 1 5/8" 1
CL40-2C158-B0 1 5/8" 2
CL40-3C158-B0 1 5/8" 3
Revision A
PRODUCT FEATURES
Made of stainless steel and U.V. resistent Fiberglass P.A.
Fast and easy assembly
Various cable dimensions
Supports up to 5 cable runs
Secured with wrench or hex key
For use with 40 mm (1.57 in) angle members
No need for adapters or drilling holes
Minimises utilised space on towers, reducing wind load
Protective interlayers safeguard against cable deformation
Typical usage examples for clamps.
1x.. 2x.. 3x.. 4x.. 5x..
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
46/11347Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Cable Clamp SingleCable Clamp Single
STANDARD CLAMPS
1/2” CABLE
ARTICLE CABLE NO. OF CABLES
CLS0-1C012-A0 1/2" 1
CLS0-2C012-A0 1/2" 2
CLS0-3C012-A0 1/2" 3
CLS0-4C012-A0 1/2" 4
7/8” CABLE
ARTICLE CABLE NO. OF CABLES
CLS0-1C078-A0 7/8" 1
CLS0-2C078-A0 7/8" 2
CLS0-3C078-A0 7/8" 3
CLS0-4C078-A0 7/8" 4
1 1/4” CABLE
ARTICLE CABLE NO. OF CABLES
CLS0-1C114-A0 1 1/4" 1
CLS0-2C114-A0 1 1/4" 2
CLS0-3C114-A0 1 1/4" 3
CLS0-4C114-A0 1 1/4" 4
1 5/8” CABLE
ARTICLE CABLE NO. OF CABLES
CLS0-1C158-A0 1 5/8" 1
CLS0-2C158-A0 1 5/8" 2
CLS0-3C158-A0 1 5/8" 3
CLS0-4C158-A0 1 5/8" 4
Revision A
PRODUCT FEATURES
Fast and easy assembly
Supports up to 4 cable runs
Minimises utilised space on towers, reducing wind load
PRODUCT PROFILE
Cable clamp single is a unit designed for safe simultaneous fixation of
coaxial cables on mountain surface. All components are specially con-
structed to work as a whole unit to support quick installation. No ad-
ditional parts for applying are required. All parts are manufactured ac-
cording to European standards. The clamps are made of environmental
protected plastic which provides UV resistance in all environments.
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
47/11348 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Cable Clamp Double
STANDARD CLAMPS
1/2” CABLE
ARTICLE CABLE NO. OF CABLES
CLD0-2C012-A0 1/2" 2
CLD0-4C012-A0 1/2" 4
CLD0-6C012-A0 1/2" 6
CLD0-8C012-A0 1/2" 8
7/8” CABLE
ARTICLE CABLE NO. OF CABLES
CLD0-2C078-A0 7/8" 2
CLD0-4C078-A0 7/8" 4
CLD0-6C078-A0 7/8" 6
CLD0-8C078-A0 7/8" 8
1 1/4” CABLE
ARTICLE CABLE NO. OF CABLES
CLD0-2C114-A0 1 1/4" 2
CLD0-4C114-A0 1 1/4" 4
CLD0-6C114-A0 1 1/4" 6
1 5/8” CABLE
ARTICLE CABLE NO. OF CABLES
CLD0-2C158-A0 1 5/8" 2
CLD0-4C158-A0 1 5/8” 4
CLD0-6C158-A0 1 5/8” 6
Cable Clamp Double
Revision A
PRODUCT FEATURES
Fast and easy assembly
Supports up to 8 cable runs
Minimises utilised space on towers, reducing wind load
PRODUCT PROFILE
Cable clamp double is a unit designed for safe simultaneous fixation of co-
axial cables on mountain surface. All components are specially constructed
to work as a whole unit to support quick installation. No additional parts
for applying are required. All parts are manufactured according to Euro-
pean standards. The clamps are made of environmental protected plastic
which provides UV resistance in all environments.
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
48/11350 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
PASSIVES
The Exir Telecom branded high performance power splitters and tappers are made
from solid copper and silver-plated to provide the most consistent and reliable elec-
trical specifications. They are water-pressure proof down to 25 metres, which cor-
responds to a pressure of 2.5 bar and far exceeds the requirements for IP68-clas-
sification. This eliminates the need for tape or any other external weatherproofing.
The LEAX range of passives cover all frequencies are rated IP66 and a cost ef-
ficient alternative for indoor use.
Exir branded Passives
Tappers, Broadbanded n dB-coupler 380 - 470 and 790 - 2700 MHz
Power Splitters, Hybrid n dB-coupler, 806 - 960 MHz
Power Splitters, Hybrid 3 dB-coupler 1710 - 2170 MHz
3 dB Hybrid, 698 - 2690 MHz
2-Way Power Splitter, 790 - 2700 MHz
3-Way Power Splitter, 790 - 2700 MHz
4-Way Power Splitter. 790 - 2700 MHz
Absorbers, 100 W
Absorbers, 50 W
Absorbers, 25 W
Absorbers, 5 W
LEAX branded Passives
Directional Coupler, 380 - 2700 MHz
Directional Coupler, 698 - 2700 MHz (2 pages)
Wideband Power Splitter, 2/3/4-way, 380-2700 MHz
Wideband Reactive Power Splitter, 2/3/4-way, 698-2700 MHz
Wideband Reactive Power Splitter, 2/3/4-way, 698-2700 MHz
Hybrid Coupler, 698-2700 MHz
Attenuator, 2 W - 200 W
Absorbers
100 W
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
49/11351Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
PRODUCT FEATURES
Extremely small
Very low insertion loss
Made of si lver-plated brass
10-year comprehensive warranty
EPDM O-rings eliminate water intrusion
IP68-classified and water-pressure proof tested down to 25 m
No need for amalgamating tape or other external weatherproofing
In Out
Out ndB
* During intermodulation measurement attached cables are exposed to shock and vibration.
Revision C
Tappers
Broadbanded n dB-coupler 380 - 470 and 790 - 2700 MHz
ARTICLE DBCM-0602-AA00 /DBCM-0602-AA01
DBCM-0702-AA00 /DBCM-0702-AA01
DBCM-1002-AA00 /DBCM-1002-AA01
DBCM-1302-AA00 /DBCM-1302-AA01
DBCM-1502-AA00 /DBCM-1502-AA01
DBCM-2002-AA00 /DBCM-2002-AA01
CONNECTORS DIN 7/16 female /
N female
DIN 7/16 female /
N female
DIN 7/16 female /
N female
DIN 7/16 female /
N female
DIN 7/16 female /
N female
DIN 7/16 female /
N female
INPUT POWER 600 / 150 W 600 / 150 W 600 / 150 W 600 / 150 W 600 / 150 W 600 / 150 W
PIECES IN BOX As requested / 50 As requested / 50 As requested / 50 As requested / 50 As requested / 50 As requested / 50FREQUENCY RANGE 380 - 470 MHz 380 - 470 MHz 380 - 470 MHz 380 - 470 MHz 380 - 470 MHz 380 - 470 MHz
790 - 2700 MHz 790 - 2700 MHz 790 - 2700 MHz 790 - 2700 MHz 790 - 2700 MHz 790 - 2700 MHz
COUPLING ATTENUATION
380 - 470 MHz -9 dB (13 % of Pin) -10 dB (10 % of Pin) -15 dB (3 % of Pin) -17 dB (2 % of Pin) -21 dB (0.8 % of Pin) -28 dB (0.15 % of Pin)
790 - 2700 MHz -6 dB (25 % of Pin) -7 dB (20 % of Pin) -10 dB (10 % of Pin) -13 dB (5 % of Pin) -15.1 dB (3 % of Pin) -20 dB (1 % of Pin)
OUTPUT PERCENTAGE 25 % / 75 % 20 % / 80 % 10 % / 90 % 5 % / 95 % 3 % / 97 % 1 % / 99 %
VSWR / RETURN LOSS
380 - 470 MHz 1.5 / 14 dB 1.5 / 15 dB 1.22 / 20 dB 1.12 / 25 dB 1.12 / 25 dB 1.12 / 25 dB
790 - 2700 MHz 1.5 / 14 dB 1.5 / 15 dB 1.22 / 20 dB 1.12 / 25 dB 1.12 / 25 dB 1.12 / 25 dB
INSERTION LOSS -0.05 dB -0.05 dB -0.05 dB -0.05 dB -0.05 dB -0.05 dB
IMPEDANCE 50 ohm 50 ohm 50 ohm 50 ohm 50 ohm 50 ohm
INTERMODULATION*
2 x 20 transmitter < -156 dBc < -156 dBc < -156 dBc < -156 dBc < -156 dBc < -156 dBc
WEIGHT 350 g (0.76 lb) 350 g (0.76 lb) 350 g (0.76 lb) 350 g (0.76 lb) 350 g (0.76 lb) 350 g (0.76 lb)
DIMENSIONS 72 x 78 x 25 mm 72 x 78 x 25 mm 72 x 78 x 25 mm 72 x 78 x 25 mm 72 x 78 x 25 mm 72 x 78 x 25 mm
H x W x D (2.84 x 3.06 x 0.97 in) (2.84 x 3.06 x 0.97 in) (2.84 x 3.06 x 0.97 in) (2.84 x 3.06 x 0.97 in) (2.84 x 3.06 x 0.97 in) (2.84 x 3.06 x 0.97 in)
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
50/11352 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Power Splitters, Hybrid n dB-coupler, 806 - 960 MHz
Power Splitters
Hybrid n dB-coupler, 806 - 960 MHz
PRODUCT FEATURES
Extremely good VSWR
Made of silver-plated brass
10-year comprehensive warranty
EPDM O-rings eliminate water intrusion
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
COMMON FOR ALL
INPUT POWER 700 W
FREQUENCY RANGE 806 - 960 MHz
VSWR / RETURN LOSS 1.06 / -31 dB
ISOLATION -33 dB
IMPEDANCE 50 ohm
WEIGHT 2000 g (4.4 lb)
OPERATING TEMP. -55 °C to +80 °C
DIMENSIONS 135 x 90 x 50 mm
H x W x D (5.32 x 3.55 x 1.96 in)
ARTICLE DBCM-0305-AA00 DBCM-0605-AA00 DBCM-1005-AA00 DBCM-1305-AA00
CONNECTORS DIN 7/16 female DIN 7/16 female DIN 7/16 female DIN 7/16 female
COUPLING ATTENUAT. 3 dB ±0.1 6 dB ±0.3 10 dB ±0.3 13 dB ±0.3
OUTPUT PERCENTAGE 50% / 50% 25% / 75% 10% / 90% 5% / 95%
Out
COMBINING SIGNALSFROM TWO TX / RXs
In
In
Absorber
In
SPLITTING SIGNALSFROM ONE TX / RX
Out
Out
Absorber
In
SPLITTING SIGNALS
FROM TWO TX / RXs
Out
Out
In
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
51/11353Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Power Splitters, Hybrid 3 dB-coupler 1710 -
2170 MHz
Power Splitters
Hybrid 3 dB-coupler 1710 - 2170 MHz
PRODUCT FEATURES
Extremely small
Very low insertion loss
Made of si lver-plated brass
10-year comprehensive warranty
EPDM O-rings eliminate water intrusion
IP68-classified and water-pressure proof tested down to 25 m
No need for amalgamating tape or other external weatherproofing
Out
COMBINING SIGNALSFROM TWO TX / RXs
In
In
Absorber
In
SPLITTING SIGNALSFROM ONE TX / RX
Out
Out
Absorber
In
SPLITTING SIGNALSFROM TWO TX / RXs
Out
Out
In
COMMON FOR ALL
FREQUENCY RANGE 1710 - 2170 MHz
COUPLING ATTENUAT. 3 dB ±0.15
OUTPUT PERCENTAGE 50% / 50%
RETURN LOSS -25 dB
ISOLATION -28 dB
IMPEDANCE 50 ohm
WEIGHT 1500 g (3.3 lb)
OPERATING TEMP. -55 °C to +80 °C
DIMENSIONS 96 x 95 x 50 mm
H x W x D (3.78 x 3.74 x 1.96 in)
ARTICLE DBCM-1722-AA01 DBCM-1722-AB01
CONNECTORS DIN 7/16 female N female
INPUT POWER 600 W 150 W
Revision A
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
52/11354 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
3 dB Hybrid
698 - 2690 MHz
3 dB Hybrid, 790-2700 MHz
Revision B
PRODUCT FEATURES
High Performance
High Reliability
Low Noise Figure
ROHS Compliant
IP67-classified
ARTICLE DBCM-0727-AA00 DBCM-0727-AA01
ELECTRICAL
FREQUENCY RANGE 698 - 2690 MHz
INSERTION LOSS ±0.8 dB
COUPLING VALUE 3.1 dB
VSWR 1.3:1 Max
ISOLATION 18 dB Min
POWER HANDLING 50 W
PIM (3rd Order 2*43dBm) -150 dBc typical
IN/OUT IMPEDANCE 50 Ohm nominal
ENVIRONMENTAL
OPERATING TEMPERATURE -20 to +70 °C
MECHANICAL
DIMENSIONS H x W x D
HYBRID 270 x 64 x 33 mm
(10.63 x 2.52 x 1.30 in)
270 x 57 x 52 mm
(10.63 x 2.24 x 2.04 in)
BRACKET 100 x 114 x 12 mm
(3.94 x 4.49 x 0.47 in)
100 x 114 x 12 mm
(3.94 x 4.49 x 0.47 in)
RF CONNECTOR N (F) 7/16 (f)
FINISH Grey colour epoxy coating
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
53/11355Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
2-Way Power Splitter, 790 - 2700 MHz2-Way Power Splitter
790 - 2700 MHz
PRODUCT FEATURES
Made from silver-plated brass
10-year comprehensive warranty
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
Out
In
Side view
Out
ARTICLE AT2G-716F-AB00 AT2G-00NF-AB00
FREQUENCY RANGE 790 - 2700 MHz 790 - 2700 MHz
INPUT POWER
790 - 960 MHz 1000 W 300 W
1700 - 2200 MHz 700 W 150 W
2500 - 2700 MHz 500 W 100 W
CONNECTORS DIN 7/16 female N female
INPUTS/OUTPUTS 1/2 1/2
VSWR / RETURN LOSS 1.17 / -22 dB 1.17 / -22 dB
INSERTION LOSS
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
54/11356 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
3-Way Power Splitter, 790 - 2700
MHz
3-Way Power Splitter
790 - 2700 MHz
PRODUCT FEATURES
Made from silver-plated brass
10-year comprehensive warranty
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 mOut
In
Side view
Out
ARTICLE AT3G-716F-AB00 AT3G-00NF-AB00
FREQUENCY RANGE 790 - 2700 MHz 790 - 2700 MHz
INPUT POWER
790 - 960 MHz 1000 W 300 W
1700 - 2200 MHz 700 W 150 W
2500 - 2700 MHz 500 W 100 W
CONNECTORS DIN 7/16 female N female
INPUTS/OUTPUTS 1/3 1/3
VSWR / RETURN LOSS 1.17 / -22 dB 1.17 / -22 dB
INSERTION LOSS
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
55/11357Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
4-Way Power Splitter
790 - 2700 MHz
PRODUCT FEATURES
Made from silver-plated brass
10-year comprehensive warranty
No need for tape or other external weatherproofing
IP68-classified and water-pressure proof tested down to 25 m
In
Out
Side view
Out
ARTICLE AT4G-716F-AB00 AT4G-00NF-AB00
FREQUENCY RANGE 790 - 2700 MHz 790 - 2700 MHz
INPUT POWER
790 - 960 MHz 1000 W 300 W
1700 - 2200 MHz 700 W 150 W
2500 - 2700 MHz 500 W 100 W
CONNECTORS DIN 7/16 female N female
INPUTS/OUTPUTS 1/4 1/4
VSWR / RETURN LOSS 1.17 / -22 dB 1.17/ -22 dB
INSERTION LOSS
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
56/11358 Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Absorbers
100 W
PRODUCT FEATURES
Rohs compliant
COMMON FOR BOTH
FREQUENCY RANGE 0 - 3000 MHz
INPUT POWER (at 25 °C) 100 W
IMPEDANCE 50 ohm
RETURN LOSS
0 - 1000 MHz 35 dB
1000 - 2500 MHz 32 dB
2500 - 3000 MHz 18 dB
OPERATING TEMPERATURE -55 °C to +80 °C
DIMENSIONS 125 x 135 x 125 mm
H x W x D (4.93 x 5.32 x 4.93 in)
WEIGHT 2400 g (5.28 lb)
Absorbers, 100 W
Revision B
ARTICLE LDB0-0100-A0 LDB0-0100-B0 LDB0-0100-C0 LDB0-0100-D0
CONNECTOR DIN 7/16 female DIN 7/16 male N female N male
-
8/20/2019 Leax Arkivator Telecom Catalogue 2014 (2)
57/11359Leax Arkivator Telecom AB P +46 8 752 02 20 [email protected] www.leax.com
Absorbers, 50 W
Absorbers
50 W
PRODUCT FEATURES
Rohs compliant
Available with BNC
COMMON FOR BOTH
FREQUENCY RANGE DC – 4000 MHz
INPUT POWER (at 25 °C) 50 W
PEAK POWER 5 kW
IMPEDANCE 50 ohm ± 2%
RETURN LOSS
0 - 2000 MHz 26 dB
2000 - 4000 MHz 20.8 dB
OPERATING TEMPERATURE -55 to +125°C
DIMENSIONS 72 x 50 x 94 mm
H x W x D (2.83 x 1.97 x 3.7 in)
WEIGHT 540 g (1.19 lb)
ARTICLE LDB0-0050-A0 LDB0-0050-B0
CONNECTOR DIN 7/16 female DIN 7/16 male
Revision B
-
8/20/2019 Leax Arkivator Telec