SPK is a large water content, gas fired, condensing boiler entirely in stainless steel AISI 316L, complete of modulating premix burner. In practice, it is the basic heating element that constitutes the extraordinary project MULTIINOX. A product able to redefine the concept of boiler.
SPK for compactness and flexibility of installation, as well as for the silence of operation, is an alternative to the low water content boilers, both, floor standing and wall hung mounted, marrying all their advantages, that are translated in: • rapid amortization • high reliability in the time • simplified maintainability.
The merits of the UNICAL low water content boilers are well known, but whereas the thermician recognizes the indispensability of the large water content, that means elimination of the primary ring and its pump, here is the SPK to fill a technological void.
SPK 116LARGE WATER CONTENT, STAINLESS STEEL,
CONDENSING BOILER
LARGE WATER CONTENT, PREMIX, CONDENSING BOILER
MODEL 119 kW output (115 kW input)
EFFICIENCY CLASS
WORKING TEMPERATURE No temperature limitation on the return connection
SUPPLY Natural gas or LPG
Thermal element with vertical development
in stainless steel AISI 316L
Large water content: 104 liters
Modulation ratio up to 1:4
Efficiency up to 107,3%
Two return connections (high and low temperature)
HIGH MODULATION PREMIX BURNER
ELECTRONIC PANEL BOARD HSCP
COMPACT DIMENSIONS
EASY AND FAST INSTALLATION
The combustion SPK 116 is constituted by:• heat exchanger with vertical tube bundle, completely in
stainless steel • smoke pipe in stainless steel of 42,4 mm diameter, with
multi-fin self-cleaning inserts in Al/Si/Mg
The combustion is produced downward from the top. The flame develops in the combustion chamber, on which bottom the multi-fin pipes, slightly tilted, are engaged, for a better thermal exchange and functional outflow of the condensates. The produced condensate is collected in an underlying tray that acts as smoke chamber. The whole cycle happens under positive pressure for an easier evacuation of the smokes.
output 119 kW (115 kW input)
maximum certified efficiency up to 107,3 % to the minimum modulated output
high modulation ratio up to 1:4
thermal element with vertical development, entirely in stainless steel AISI 316L complete of premix modulating burner
special smoke pipes (Unica patent) in stainless steel with multi-fin inserts in Al/Si/Mg with high thermal conductibility, on purpose designed to improve the outflow of the condensate and to optimize the water circulation
cylindrical combustion chamber with passing bottom
vertical burner complete of safety devices
smoke non return valve
electronic controlling system HSCP with proportional regulation seasonal efficiency + 30% higher ithan the conventional boilers
optional modulating pump directly managed by the boiler, to assure the maximum condensation at all working regimes
manometric head available to the smokes outlet: + 70 Pa
compact dimensions: height 1710 x width 550 x depth 610 mm
1 - Gas pressure switch2 - Fan3 - Combustion chamber door4 - Furnace 5 - Panel board6 - Boiler water7 - Vertical smoke pipes in stainless steel with aluminum fins
2
3
4
5
6
7
89
1
SPK 116strength’s points
BREVETTO
Multiradial aluminum fins
External pipe in stainless steel
AISI 316L
8 - Condensate tray witn level sensor9 - Smoke chamberG - Gas supply connection 3/4’M - C.H. flow connection 2’’Rat - High temperature return
connection 2’’Rbt - Low temperature return
connection 2’’
Premix burner Main protagonist for a perfect combustion and, therefore, an optimum efficiency, is the Modulating Fan (1000 to 6000 rpm) of which the boiler is equipped.
The number of revolutions per minute of the fan, together with the opening of the gas valve and the flame control, are directly programmed and checked by the electronics of the burner (BMM Burner Module Manager) and, at their turn, managed by the HSCP controller.
The modulation of the output depends on the number of revolutions of the fan, that vary, therefore, according to the temperature required by the C.H.system, the set point temperature and the actual measured temperature.
The opening of the valve gas is produced for “Venturi effect” in the fan COCHLEA and the mixture air and gas happens in its inside before being introduced in combustion chamber (premix). The combustion happens on the cylindrical burner surface made of special fabric in FeCr Alloy.
Fan gasket
GAS
AIR
Air inlet Fan
The wide surface on which the combustion happens guarantees• low combustion temperature• reduced turbulencewith the following advantages:
greater transmitted energy in comparison to a traditional burner with the same flame temperature
absolute working safety due to the absence of turbulences
limited production of pollutants for the complete oxidation of the molecules of methane • excellent combustion efficiency: maximum
CO2 = 9,1% • attainment of the condensation regime already with
return temperatures of (54°C) • optimization of the efficiency thanks to the low
smoke temperature and “air excess” • low NOX emissions: 82,14 mg/kWh (weighted value
according to EN 297 A3).
Hydrodynamics The heat exchange with the system is guaranteed by specific return collectors (one for high and one for low temperature) to exploit at the most the efficiency of the heat exchanger.
Large diameter flanges (M/Rat/Rbt: DN 125) assure the maximum circulation with low pressure losses.
The water, through the forced circulation, winds completely the stainless steel tube bundle of the boiler and, once heated, is pushed in the flow pipe.
CONFIGURATION:
The valve is directly fitted on on the fan. Insi-
de the volute of the fan takes place
the air/gas premixing exactly calibrated.
* at nominal input in condensation
Power and flexibility Unical supplies the best possible motor and the most effective and flexible way to control it, in function of the heating system that needs to be managed. In this case it is possible to exploit both, the suitability of the burner modulation and the boiler condensation for the maximum energetic saving !
HSCP: Heating System Control Panel is the new control system. It is made to be the clear, simple and flexible dialogue window with the boiler, in order to notice and to automatically connect among them, via eBUS, more devices in different points of the heating system.
This, unlike the connections pin to pin, allows the simple expansion of the system through the connection of special multifunction cards SHC (Slavic Heating Controller) for the management of the passive loads and / or further active energetic resources; in this way it is possible to exploit several functions. Thanks to the SHCs it is possible to use, and then to buy, only the optional necessary cards and to set the functions through the variation of a simple dedicated parameter.
Every SHC checks up to 3 heating circuits, has 3 entries for NTC temperature sensors and 2 entries for PT1000 probes for solar circuits. It is possible to connect up to n°4 cards SHC and therefore to manage up to 12 heating circuits.
Dimensions and technical data C
od. 4
7581
- E
d.1
- 06
/201
3SPK 116
NOMINAL OUTPUT 50/30 °C kW 119
NOMINAL OUTPUT 80/60 °C kW 113
EFFICIENCY CLASS HHHH CE
NOMINAL INPUT kW 115
WATER EFFICIENCY * % 103,8
EFFICIENCY TO THE NOMINAL OUTPUT % 107,3
Height mm 1710
Width mm 550
Depth mm 610
WEIGHT kg 270
A low tension feeder is available in case of mounting in the boiler house panel board.
The card BCM (Burner Cascade Manager) elaborates the data related to the measured flow temperature and the temperature calculated by the system; then if a modulating pump is connected, will have: • Increase of the pump flow rate if the Delta T increases
too much • Reduction of the pump flow rate if the Delta reduces
too much.
- MULTIFUNCTION MODULE SHC (zones management) Code 00362317 It is possible to pilot uo to a maximum of 4 cards SHC
- MULTIFUNCTION MODULES FEEDER Code 00362379
- Probe PT 1000 for management of solar collectors Code 00362282
Accessories (optional) Condensate neutralization systems (optional)- CONDENSATE NEUTRALIZERS Code 00262827 KIT NH 300 (up to 300 kW)
- Recharge of salts forneutralizers Refill NH 25 kg Code 00262830
SIDE VIEW FRONT VIEW REAR VIEW
Unical AG declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves the right to introduce those modifications to its products that it considers necessary or useful, without compromising the essential characteristics of the said products.
AG S.p.A. 46033 casteldario - mantova - italy - ph. +39 0376 57001 - fax +39 0376 660556 - [email protected] - www.unical.eu