B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
AKENT C. LEIGH PREPARED: DATE:
CHECKED:
ENGINEER:
APPROVED: 7YQL0SCALE: NONE
REVDRAWING NO.FSCMSIZE
CREVISION STATUS
0 0
1
1
2
2
3 4 5 6 7 8 9
LTR DESCRIPTION DATE APPROVAL
KLRT4-m26cd-yyyzz4-Channel
Remote UnitTVRO
01-15-2018
SHEET 1 OF 11REFERENCESNO. TITLE DWG NUMSHT DESCRIPTION
1 Title Sheet, List of References & Index
DRAWING INDEX
8 KLRT4-526MM-S4B Installation Control Drawing: Outline & Mounting
- -
01-15-2018Initial Release- KCLEIGH
18011503 -7YQL0-18011503_ - MD-KLRT4-m26cd-yyyzz_.cdr
-
9 FCU Functional DiagramKLRT4-526MM-S4B
KLfiber Market Brochure
11 Typical Commercial TVRO ConfigurationKLfiber
- -
NOTES:
1. KLaaabb-m2ncM-yyyzz corresponds to laser modifications for military spec connectors.
2. KLaaabb-m2ncC-yyyzz corresponds to laser modifications for commercial grade connectors.
3. KLaaabb-m2ncd-S4zz corresponds to a Remote Unit configured with a single serial M&C port.
4. KLaaabb-m2ncd-S42zz corresponds to a Remote Unit configured with dual serial M&C ports.
5. This document provides information pertaining only to the 4-channel TVRO Remote Unit variations. KLfiber additionally provides 256 unique 6-channel TVRO unit variations when special ordered.
6. There are 260 different 4-Channel configurations of the KLfiber Remote Unit as listed on sheets 2 & 3.
10 Typical TVRO ConfigurationKLfiber Military
1 KLfiber Part Number Configuration Control 7YQL0-18011501
2 KLRT4 TVRO Non-Multiplexed Units Configuration Listing (Sheet 1 of 2)
- -
4-7 KLRT4 TVRO Configuration Listing (Sheets 1-4 of 4)Multiplexed Units
-
3 KLRT4 TVRO Non-Multiplexed Units Configuration Listing (Sheet 2 of 2)
-- -
KL - 2 -RaaT4 m ncd yyyBzz
G GPS - 50 Ohm
M MUX/DEMUX
S SARSAT - 50 Ohm
T1 1-Channel TVRO - 75 Ohm
T2 2-Channel TVRO - 75 Ohm
T4 4-Channel TVRO - 75 Ohm
T6 6-Channel TVRO - 75 Ohm
V 2-Ch Tx/Rx VSAT - 50 Ohm
X Tracker - 50 Ohm
Application
CC Commercial RF & I/O
CM Commercial RF & MILSPEC I/O
MC MILSPEC RF & Commercial I/OMM MILSPEC RF & I/O
Config RF & I/O
N NoneS2 RS232-Unit I/O
S22 RS232-Unit I/O & RS232-Comm Port
S4 RS422-Unit I/OS42 RS422-Unit I/O & RS232-Comm PortS5 RS485-Unit I/O
S52 RS485-Unit I/O & RS232-Comm PortT EoC-Unit I/O
T2 EoC-Unit I/O & RS232-Comm PortW Wireless-Unit I/O
W2 Wireless-Unit I/O & RS232-Comm Port
M_C
C Standard Central Unit
CW4 WDM 4:n Central Unit
CW8 WDM 8:n Central Unit
M04 WDM 4:n Multiplexer
M08 WDM 8:n Multiplexer
M16 WDM 16:n Multiplexer
R Standard Remote Unit
RW4 WDM 4:n Remote Unit
RW8 WDM 8:n Remote Unit
S System Configuration
Unit Type
B Bcst
D LNB & Bcst
L LNB
LA LNA
N No Output Power
Power
Input/Output RF/M&C Chan's
Input/Output Optical Chan's
m:
n:
aaa: bb:
cd:
yyy: zz:
KK
KLfiber
LL
LM LNB & (Maintenance Cut-Off)
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A
18011503 - SHEET 2 OF
KLRT4-m2ncd-yyyzz Remote Unit Configurations
Non-Multiplexed Units (Sht 1 of 2)
1 KLRT4-424CC-NL 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O None LNB
2 KLRT4-424CC-NLM 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O None LNB (Maint)
3 KLRT4-424CC-NN 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O None None
4 KLRT4-424CM-NL 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O None LNB
5 KLRT4-424CM-NLM 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O None LNB (Maint)
6 KLRT4-424CM-NN 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O None None
7 KLRT4-424MC-NL 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O None LNB
8 KLRT4-424MC-NLM 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O None LNB (Maint)
9 KLRT4-424MC-NN 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O None None
10 KLRT4-424MM-NL 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O None LNB
11 KLRT4-424MM-NLM 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O None LNB (Maint)
12 KLRT4-424MM-NN 4 Chans 4 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O None None
13 KLRT4-426CC-S2L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS232-Unit I/O LNB
14 KLRT4-426CC-S2LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS232-Unit I/O LNB (Maint)
15 KLRT4-426CC-S4L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS422-Unit I/O LNB
16 KLRT4-426CC-S4LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS422-Unit I/O LNB (Maint)
17 KLRT4-426CC-S5L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS485-Unit I/O LNB
18 KLRT4-426CC-S5LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS485-Unit I/O LNB (Maint)
19 KLRT4-426CC-TL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O EoC-Unit I/O LNB
20 KLRT4-426CC-TLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O EoC-Unit I/O LNB (Maint)
21 KLRT4-426CC-WL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O Wireless-Unit I/O LNB
22 KLRT4-426CC-WLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O Wireless-Unit I/O LNB (Maint)
23 KLRT4-426CM-S2L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O LNB
24 KLRT4-426CM-S2LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O LNB (Maint)
25 KLRT4-426CM-S4L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O LNB
26 KLRT4-426CM-S4LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O LNB (Maint)
27 KLRT4-426CM-S5L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O LNB
28 KLRT4-426CM-S5LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O LNB (Maint)
29 KLRT4-426CM-TL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O LNB
30 KLRT4-426CM-TLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O LNB (Maint)
31 KLRT4-426CM-WL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O LNB
32 KLRT4-426CM-WLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O LNB (Maint)
33 KLRT4-426MC-S2L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O LNB
34 KLRT4-426MC-S2LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O LNB (Maint)
35 KLRT4-426MC-S4L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O LNB
36 KLRT4-426MC-S4LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O LNB (Maint)
37 KLRT4-426MC-S5L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O LNB
38 KLRT4-426MC-S5LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O LNB (Maint)
39 KLRT4-426MC-TL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O LNB
40 KLRT4-426MC-TLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O LNB (Maint)
41 KLRT4-426MC-WL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O LNB
42 KLRT4-426MC-WLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O LNB (Maint)
43 KLRT4-426MM-S2L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS232-Unit I/O LNB
44 KLRT4-426MM-S2LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS232-Unit I/O LNB (Maint)
45 KLRT4-426MM-S4L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS422-Unit I/O LNB
46 KLRT4-426MM-S4LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS422-Unit I/O LNB (Maint)
Model Number RF/M&C OPTICAL Function Configuration M&C Output Power
Remote Converter Unit Configurations
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A
18011503 - SHEET 2 OF
KLRT4-m2ncd-yyyzz Remote Unit Configurations
Non-Multiplexed Units (Sht 2 of 2)
Model Number RF/M&C OPTICAL Function Configuration M&C Output Power
Remote Converter Unit Configurations
47 KLRT4-426MM-S5L 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS485-Unit I/O LNB
48 KLRT4-426MM-S5LM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS485-Unit I/O LNB (Maint)
49 KLRT4-426MM-TL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O EoC-Unit I/O LNB
50 KLRT4-426MM-TLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O EoC-Unit I/O LNB (Maint)
51 KLRT4-426MM-WL 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O Wireless-Unit I/O LNB
52 KLRT4-426MM-WLM 4 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O Wireless-Unit I/O LNB (Maint)
53 KLRT4-526CC-S22L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS232-Unit I/O & RS232-Comm Port LNB
54 KLRT4-526CC-S22LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
55 KLRT4-526CC-S42L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS422-Unit I/O & RS232-Comm Port LNB
56 KLRT4-526CC-S42LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
57 KLRT4-526CC-S52L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS485-Unit I/O & RS232-Comm Port LNB
58 KLRT4-526CC-S52LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
59 KLRT4-526CC-T2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O EoC-Unit I/O & RS232-Comm Port LNB
60 KLRT4-526CC-T2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
61 KLRT4-526CC-W2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB
62 KLRT4-526CC-W2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
63 KLRT4-526CM-S22L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O & RS232-Comm Port LNB
64 KLRT4-526CM-S22LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
65 KLRT4-526CM-S42L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O & RS232-Comm Port LNB
66 KLRT4-526CM-S42LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
67 KLRT4-526CM-S52L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O & RS232-Comm Port LNB
68 KLRT4-526CM-S52LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
69 KLRT4-526CM-T2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O & RS232-Comm Port LNB
70 KLRT4-526CM-T2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
71 KLRT4-526CM-W2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O & RS232-Comm Port LNB
72 KLRT4-526CM-W2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
73 KLRT4-526MC-S22L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O & RS232-Comm Port LNB
74 KLRT4-526MC-S22LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
75 KLRT4-526MC-S42L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O & RS232-Comm Port LNB
76 KLRT4-526MC-S42LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
77 KLRT4-526MC-S52L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O & RS232-Comm Port LNB
78 KLRT4-526MC-S52LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
79 KLRT4-526MC-T2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O & RS232-Comm Port LNB
80 KLRT4-526MC-T2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
81 KLRT4-526MC-W2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O & RS232-Comm Port LNB
82 KLRT4-526MC-W2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
83 KLRT4-526MM-S22L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS232-Unit I/O & RS232-Comm Port LNB
84 KLRT4-526MM-S22LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
85 KLRT4-526MM-S42L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS422-Unit I/O & RS232-Comm Port LNB
86 KLRT4-526MM-S42LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
87 KLRT4-526MM-S52L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS485-Unit I/O & RS232-Comm Port LNB
88 KLRT4-526MM-S52LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
89 KLRT4-526MM-T2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O EoC-Unit I/O & RS232-Comm Port LNB
90 KLRT4-526MM-T2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
91 KLRT4-526MM-W2L 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB
92 KLRT4-526MM-W2LM 5 Chans 6 Chans 4-Channel TVRO - 75 Ohm; Standard Remote Unit MILSPEC RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A
KLRaaT4-m2ncd-yyyzz Remote Unit Configurations
Multiplexed Units (Sheet 1 of 4)
SHEET 4 OF
18011503 -
1 KLRW4T4-421CC-NL 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit Commercial RF & I/O None LNB
2 KLRW4T4-421CC-NLM 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit Commercial RF & I/O None LNB (Maint)
3 KLRW4T4-421CM-NL 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit Commercial RF & MILSPEC I/O None LNB
4 KLRW4T4-421CM-NLM 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit Commercial RF & MILSPEC I/O None LNB (Maint)
5 KLRW4T4-421MC-NL 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit MILSPEC RF & Commercial I/O None LNB
6 KLRW4T4-421MC-NLM 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit MILSPEC RF & Commercial I/O None LNB (Maint)
7 KLRW4T4-421MM-NL 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit MILSPEC RF & I/O None LNB
8 KLRW4T4-421MM-NLM 4 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 4:n Remote Unit MILSPEC RF & I/O None LNB (Maint)
9 KLRW8T4-521CC-S2L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O LNB
10 KLRW8T4-521CC-S2LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O LNB (Maint)
11 KLRW8T4-521CC-S4L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O LNB
12 KLRW8T4-521CC-S4LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O LNB (Maint)
13 KLRW8T4-521CC-S5L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O LNB
14 KLRW8T4-521CC-S5LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O LNB (Maint)
15 KLRW8T4-521CC-TL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O LNB
16 KLRW8T4-521CC-TLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O LNB (Maint)
17 KLRW8T4-521CC-WL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O LNB
18 KLRW8T4-521CC-WLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O LNB (Maint)
19 KLRW8T4-521CM-S2L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O LNB
20 KLRW8T4-521CM-S2LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O LNB (Maint)
21 KLRW8T4-521CM-S4L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O LNB
22 KLRW8T4-521CM-S4LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O LNB (Maint)
23 KLRW8T4-521CM-S5L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O LNB
24 KLRW8T4-521CM-S5LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O LNB (Maint)
25 KLRW8T4-521CM-TL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O LNB
26 KLRW8T4-521CM-TLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O LNB (Maint)
27 KLRW8T4-521CM-WL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O LNB
28 KLRW8T4-521CM-WLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O LNB (Maint)
29 KLRW8T4-521MC-S2L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O LNB
30 KLRW8T4-521MC-S2LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O LNB (Maint)
31 KLRW8T4-521MC-S4L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O LNB
32 KLRW8T4-521MC-S4LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O LNB (Maint)
33 KLRW8T4-521MC-S5L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O LNB
34 KLRW8T4-521MC-S5LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O LNB (Maint)
35 KLRW8T4-521MC-TL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O LNB
36 KLRW8T4-521MC-TLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O LNB (Maint)
37 KLRW8T4-521MC-WL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O LNB
38 KLRW8T4-521MC-WLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O LNB (Maint)
39 KLRW8T4-521MM-S2L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O LNB
40 KLRW8T4-521MM-S2LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O LNB (Maint)
41 KLRW8T4-521MM-S4L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O LNB
42 KLRW8T4-521MM-S4LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O LNB (Maint)
43 KLRW8T4-521MM-S5L 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O LNB
44 KLRW8T4-521MM-S5LM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O LNB (Maint)
Model Number RF/M&C OPTICAL Function Configuration M&C Output Power
Remote Converter Unit Configurations
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A SHEET 5 OF
KLRaaT4-m2ncd-yyyzz Remote Unit Configurations
Multiplexed Units (Sheet 2 of 4)
18011503 -
45 KLRW8T4-521MM-TL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O LNB
46 KLRW8T4-521MM-TLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O LNB (Maint)
47 KLRW8T4-521MM-WL 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O LNB
48 KLRW8T4-521MM-WLM 5 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O LNB (Maint)
49 KLRW8T4-522CC-S2L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O LNB
50 KLRW8T4-522CC-S2LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O LNB (Maint)
51 KLRW8T4-522CC-S4L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O LNB
52 KLRW8T4-522CC-S4LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O LNB (Maint)
53 KLRW8T4-522CC-S5L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O LNB
54 KLRW8T4-522CC-S5LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O LNB (Maint)
55 KLRW8T4-522CC-TL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O LNB
56 KLRW8T4-522CC-TLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O LNB (Maint)
57 KLRW8T4-522CC-WL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O LNB
58 KLRW8T4-522CC-WLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O LNB (Maint)
59 KLRW8T4-522CM-S2L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O LNB
60 KLRW8T4-522CM-S2LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O LNB (Maint)
61 KLRW8T4-522CM-S4L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O LNB
62 KLRW8T4-522CM-S4LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O LNB (Maint)
63 KLRW8T4-522CM-S5L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O LNB
64 KLRW8T4-522CM-S5LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O LNB (Maint)
65 KLRW8T4-522CM-TL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O LNB
66 KLRW8T4-522CM-TLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O LNB (Maint)
67 KLRW8T4-522CM-WL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O LNB
68 KLRW8T4-522CM-WLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O LNB (Maint)
69 KLRW8T4-522MC-S2L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O LNB
70 KLRW8T4-522MC-S2LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O LNB (Maint)
71 KLRW8T4-522MC-S4L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O LNB
72 KLRW8T4-522MC-S4LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O LNB (Maint)
73 KLRW8T4-522MC-S5L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O LNB
74 KLRW8T4-522MC-S5LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O LNB (Maint)
75 KLRW8T4-522MC-TL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O LNB
76 KLRW8T4-522MC-TLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O LNB (Maint)
77 KLRW8T4-522MC-WL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O LNB
78 KLRW8T4-522MC-WLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O LNB (Maint)
79 KLRW8T4-522MM-S2L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O LNB
80 KLRW8T4-522MM-S2LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O LNB (Maint)
81 KLRW8T4-522MM-S4L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O LNB
82 KLRW8T4-522MM-S4LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O LNB (Maint)
83 KLRW8T4-522MM-S5L 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O LNB
84 KLRW8T4-522MM-S5LM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O LNB (Maint)
85 KLRW8T4-522MM-TL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O LNB
86 KLRW8T4-522MM-TLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O LNB (Maint)
87 KLRW8T4-522MM-WL 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O LNB
88 KLRW8T4-522MM-WLM 5 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O LNB (Maint)
Model Number RF/M&C OPTICAL Function Configuration M&C Output Power
Remote Converter Unit Configurations
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A SHEET 6 OF
KLRaaT4-m2ncd-yyyzz Remote Unit Configurations
Multiplexed Units (Sheet 3 of 4)
18011503 -
89 KLRW8T4-621CC-S22L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O & RS232-Comm Port LNB
90 KLRW8T4-621CC-S22LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
91 KLRW8T4-621CC-S42L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O & RS232-Comm Port LNB
92 KLRW8T4-621CC-S42LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
93 KLRW8T4-621CC-S52L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O & RS232-Comm Port LNB
94 KLRW8T4-621CC-S52LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
95 KLRW8T4-621CC-T2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O & RS232-Comm Port LNB
96 KLRW8T4-621CC-T2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
97 KLRW8T4-621CC-W2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB
98 KLRW8T4-621CC-W2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
99 KLRW8T4-621CM-S22L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O & RS232-Comm Port LNB
100 KLRW8T4-621CM-S22LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
101 KLRW8T4-621CM-S42L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O & RS232-Comm Port LNB
102 KLRW8T4-621CM-S42LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
103 KLRW8T4-621CM-S52L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O & RS232-Comm Port LNB
104 KLRW8T4-621CM-S52LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
105 KLRW8T4-621CM-T2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O & RS232-Comm Port LNB
106 KLRW8T4-621CM-T2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
107 KLRW8T4-621CM-W2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O & RS232-Comm Port LNB
108 KLRW8T4-621CM-W2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
109 KLRW8T4-621MC-S22L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O & RS232-Comm Port LNB
110 KLRW8T4-621MC-S22LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
111 KLRW8T4-621MC-S42L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O & RS232-Comm Port LNB
112 KLRW8T4-621MC-S42LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
113 KLRW8T4-621MC-S52L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O & RS232-Comm Port LNB
114 KLRW8T4-621MC-S52LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
115 KLRW8T4-621MC-T2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O & RS232-Comm Port LNB
116 KLRW8T4-621MC-T2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
117 KLRW8T4-621MC-W2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O & RS232-Comm Port LNB
118 KLRW8T4-621MC-W2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
119 KLRW8T4-621MM-S22L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O & RS232-Comm Port LNB
120 KLRW8T4-621MM-S22LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
121 KLRW8T4-621MM-S42L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O & RS232-Comm Port LNB
122 KLRW8T4-621MM-S42LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
123 KLRW8T4-621MM-S52L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O & RS232-Comm Port LNB
124 KLRW8T4-621MM-S52LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
125 KLRW8T4-621MM-T2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O & RS232-Comm Port LNB
126 KLRW8T4-621MM-T2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
127 KLRW8T4-621MM-W2L 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB
128 KLRW8T4-621MM-W2LM 6 Chans 1 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
129 KLRW8T4-622CC-S22L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O & RS232-Comm Port LNB
130 KLRW8T4-622CC-S22LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
131 KLRW8T4-622CC-S42L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O & RS232-Comm Port LNB
132 KLRW8T4-622CC-S42LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
Model Number RF/M&C OPTICAL Function Configuration M&C Output Power
Remote Converter Unit Configurations
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A
KLRaaT4-m2ncd-yyyzz Remote Unit Configurations
Multiplexed Units (Sheet 4 of 4)
SHEET 7 OF
18011503 -
133 KLRW8T4-622CC-S52L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O & RS232-Comm Port LNB
134 KLRW8T4-622CC-S52LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
135 KLRW8T4-622CC-T2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O & RS232-Comm Port LNB
136 KLRW8T4-622CC-T2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
137 KLRW8T4-622CC-W2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB
138 KLRW8T4-622CC-W2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
139 KLRW8T4-622CM-S22L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O & RS232-Comm Port LNB
140 KLRW8T4-622CM-S22LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
141 KLRW8T4-622CM-S42L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O & RS232-Comm Port LNB
142 KLRW8T4-622CM-S42LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
143 KLRW8T4-622CM-S52L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O & RS232-Comm Port LNB
144 KLRW8T4-622CM-S52LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
145 KLRW8T4-622CM-T2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O & RS232-Comm Port LNB
146 KLRW8T4-622CM-T2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
147 KLRW8T4-622CM-W2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O & RS232-Comm Port LNB
148 KLRW8T4-622CM-W2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit Commercial RF & MILSPEC I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
149 KLRW8T4-622MC-S22L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O & RS232-Comm Port LNB
150 KLRW8T4-622MC-S22LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
151 KLRW8T4-622MC-S42L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O & RS232-Comm Port LNB
152 KLRW8T4-622MC-S42LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
153 KLRW8T4-622MC-S52L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O & RS232-Comm Port LNB
154 KLRW8T4-622MC-S52LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
155 KLRW8T4-622MC-T2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O & RS232-Comm Port LNB
156 KLRW8T4-622MC-T2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
157 KLRW8T4-622MC-W2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O & RS232-Comm Port LNB
158 KLRW8T4-622MC-W2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & Commercial I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
159 KLRW8T4-622MM-S22L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O & RS232-Comm Port LNB
160 KLRW8T4-622MM-S22LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS232-Unit I/O & RS232-Comm Port LNB (Maint)
161 KLRW8T4-622MM-S42L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O & RS232-Comm Port LNB
162 KLRW8T4-622MM-S42LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS422-Unit I/O & RS232-Comm Port LNB (Maint)
163 KLRW8T4-622MM-S52L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O & RS232-Comm Port LNB
164 KLRW8T4-622MM-S52LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O RS485-Unit I/O & RS232-Comm Port LNB (Maint)
165 KLRW8T4-622MM-T2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O & RS232-Comm Port LNB
166 KLRW8T4-622MM-T2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O EoC-Unit I/O & RS232-Comm Port LNB (Maint)
167 KLRW8T4-622MM-W2L 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB
168 KLRW8T4-622MM-W2LM 6 Chans 2 Chans 4-Channel TVRO - 75 Ohm; WDM 8:n Remote Unit MILSPEC RF & I/O Wireless-Unit I/O & RS232-Comm Port LNB (Maint)
Model Number RF/M&C OPTICAL Function Configuration M&C Output Power
Remote Converter Unit Configurations
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A
KLRT4-m26cd-SyyBz O&MFiber Converter Unit
SHEET 8 OF
18011503 -
NOTES:
1. FCA COMM (J7) is available upon request and is a special order item.
2. All dimensions, unless otherwise specified, are in inches.
Note 1
VIEW A-A
4.8
5”
1.6
0”
3.2
5”
3
4
5
6
1
2
7
8
A
A
12
.62
”
11.8
5”
18.18"
18.99 +.01/.00"
TOP VIEWPowder coat:
RAL 7032 or Equiv
M14 CAPTIVEMOUNTING SCREWS
LID
LIDSCREW
BASE
KLRT4-526cM-Sx2LM Shown
B CCC
90-250VAC
A
FTx 1
Tx 3
Tx 2
Tx 4
FIBER OUTPUT
+12VDC
POWER
+24VDC
C
C
C
C
C
C-LH/HKuLO-H
C-RH/VKuLO-V
Ku HI-H
Ku HI-V
LNB
+13VDC
+18VDC
L-BAND I/O
FE US SU EF C
A
B
C
KLfiberRemote Unit
Fiber Alarm
FCA COMM
B
MAINTENANCE
Fiber Input
D
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
REVDRAWING NO.FSCMSIZE
C 7YQL0SCALE: N/A
Bias-T
DCGND
Bias-T
DCGND
Bias-T
DCGND
Bias-T
DCGND
J3
J5
J4
J6
Typical KLfiber Remote UnitTVRO Functional Diagram
SHEET 9 OF
18011503 -
M&C SYSTEM REMOTE UNIT XMT
M&C SYSTEM RCVREMOTE UNIT
M28876/11C1P1 (MILSPEC ONLY)
L-Band
FiberXMTR NO.1
A1
DS5
DS6
DS7
FCU Fiber to DataConverter
SYSTEMMonitor
&Control(M&C)
FCU
INTERNALM&C
FL1
+12VDCREG
LNG
+24VDCREG
FCU POWER
+13VDCREG
+18VDCREG C/Ku RHCP
Ku Lo V
C/Ku LHCPKu Lo H Ku Hi V
Ku Hi H
++12VDC
+12VDC
DS8
+12VDCDS1
+13VDC
DS2
DS3
+24VDC
+18VDCDS4
NOTES:
1. DS 1 provides an On-Line status of the FCU +12VDC power supply output.
2. DS2 provides
3. DS3 displays the status of the +13VDC provided for the LNB. DS4
4. DS5 through DS8 display the operational status of each individual fiber optic converter.
a. When an individual converter LED is extinguished, the fiber optic signal is available at the corresponding transmitter output.
5. The illustrated FCU M&C factory
configuration is implemented by utilizing an RS-422 configuration.
an On-Line status of the FCU +24VDC power supply output.
displays status of he +13VDC provided for the LNB.
b. When an individual converter LED is illuminated, it is an indication of a fiber converter fault. This indicates that no fiber optic signal output is available f r o m t h e c o r r e s p o n d i n g transmitter output.
7. Unless otherwise stated, Color Code implemented: RED [+24VDC]; BLU [+12VDC]; VIO [MON]; BLK [GND]4. Primary AC color codes i l l u s t r a t e d s u p p o r t E U R O specifications. UL Listed cordage is an acceptable alternative: AC Line [BLK]; AC Neut [WHT]; and Safety Ground [GRN].
4. This FCU presents a regulated +13VDC to J3 and J4 to provide the Integrated Receiver/Decoders (IRDs) with the correct polarization voltage necessary for either Right Hand Circular Polarization (RHCP) or Vertical Linear polarization to enable the correct cross-connection of their respective inputs through a passive switch. The FCU also presents a regulated +18VDC to J5 and J6 to provide the IRDs with the correct po lar izat ion vo l tage necessary for either Left Hand Circular Polarization (LHCP) or Horizontal Linear polarization to enable the correct cross-connection of their respective inputs through a passive switch.
6. Commercial systems do not utilize the MILSPEC J3 connector.
LNB
J1
J2
FiberXMTR NO.3
A3
FiberXMTR NO.2
A2
FiberXMTR NO.4
A4
FCU RF to DataConverter
AntennaMonitor
&Control(M&C)
+13VDC
+18VDC
FiberInput
AC PWRInput
AntennaM&C
J3J1 J2 J4 J5 J6 J7
B
+13VDC +18VDC
C/KuLORHCP/V KuHI HKuHI V
C/KuLOLHCP/H
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
SCALE:
C 7YQL0REVDRAWING NO.CAGESIZE
KLRT4-426MM-S4L SHOWN
Fusion Terminal Assembly
2
FIBER SPLICING TABLE
FUNCTION COLOR
Rmte Antenna XMT M&C BLURmte Antenna RCV M&C ORGC/KuLO RHCP/V GRNKuHI V BRN
SLTWHT
KuHI VC/KuLO LHCP/H
9
27 2 ea
Satellite Receiver
Satellite Receiver
Satellite Receiver
C/KuLO RHCP or V
C/KuLO LHCP or H
KuHI Vert
KuHI Horz
Passive Switchor
Matrix Switch
4 X 8 or 4 X 16
THRES 1500
FREQ 1210
SAT 125WSea Tel, inc.DAC2202
Antenna Control Unit
TRACKING
SEARCHING
POWER
TARGET
INITIALIZING
ERROR
SHIPSATELLITEANTENNA
STATUS
NEXT
TRACK
ENTER
RESET
POWER
SETUPSETUP
NID 0000
Fusion Terminal Assembly
B
C
CC
90-250VAC
A
F
Fiber Link
Tx 1
Tx 3
Tx 2
Tx 4
D
FIBEROUTPUT
+12VDC
POWER
+24VDC
C
C
C
KLfiberRemote Unit
C
C
C/KuLOLHCP-H
C/KuLORHCP-V
Ku HI H
Ku HI V
LNB
+13VDC
+18VDC
L-BAND I/O
FE US SU EF
C
A
B
C
1W-4001
1W-4003
1W-4004
1W-4005
C RHCP or V / KuLO V
C LHCP or H / KuLO H
KuHI Vert
KuHI Horz
KLCT4-526MM-S4B SHOWN
None
Typical KLfiber Military TVRO Configuration
SHT 10 OF
18011503 -
B
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
H
G
F
E
D
C
A
SCALE:
C 7YQL0REVDRAWING NO.CAGESIZE
1 1 1 1 1 1
Ku HIAC PWR
InputAntenna
M&C
J1 J2 J4 J5 J6 J7J3-1 J3-2 J3-3 J3-4 J3-5 J3-6
LHCP RHCPRS-422 M&C
Fiber Optic Connection Panel
IN OUTC RH/VKuLO V
C LH/HLH/HV H
C RH/VKuLO V KuHI HKuHI V
+13VDC +18VDC
C LH/HKuLO H
Typical KLfiber Commercial TVRO Configuration
SHT 11 OF
Fusion Terminal Assembly
1 2 3 4 5 6
1 2 3 4 5 6
Fusion Terminal Assembly
FIBER SPLICING TABLE
FUNCTION COLOR
Rmte Antenna XMT M&C BLURmte Antenna RCV M&C ORGC/KuLO RHCP/V GRNKuHI V BRN
SLTWHT
KuHI VC/KuLO LHCP/H
1 2 3 4 5 6
1 2 3 4 5 6
Satellite Receiver
Satellite Receiver
Satellite Receiver
C RHCP or V / KuLO V
C LHCP or H / KuLO H
KuHI Vert
KuHI Horz
Passive Switchor
Matrix Switch
4 X 8 or 4 X 16
THRES 1500
FREQ 1210
SAT 125WSea Tel, inc.DAC2202
Antenna Control Unit
TRACKING
SEARCHING
POWER
TARGET
INITIALIZING
ERROR
SHIPSATELLITEANTENNA
STATUS
NEXT
TRACK
ENTER
RESET
POWER
SETUPSETUP
NID 0000
18011503 -
B
C
C
90-250VAC
A
F
Fiber Link
Tx 1
Tx 3
Tx 2
Tx 4
FIBEROUTPUT
+12VDC
POWER
+24VDC
C
C
C
KLfiberRemote Unit
C
C
C/KuLOLHCP-H
C/KuLORHCP-V
Ku HI H
Ku HI V
LNB
+13VDC
+18VDC
L-BAND I/O
FE US SU EF
C
A
B
C
KLRT4-426MC-S4L SHOWN
C 1W-4001
1W-4003
1W-4004
1W-4005
C RHCP or V / KuLO V
C LHCP or H / KuLO H
KuHI Vert
KuHI Horz
KLCT4-526MC-S4B SHOWN