kitchen RoomTable of contentsProject Cover1Table of contents2Luminaire parts list3PHILIPS FBS285/218 NORMALLuminaire Data Sheet4FBS285/218 NORMALLDC (Polar)5LDC (Linear)6UGR-Table7Summary8Luminaire parts list9Photometric Results103D Rendering11Room SurfacesIsolines (E, Perpendicular)12Value Chart (E, Perpendicular)13Room 1
kitchen RoomCalculation Surface 2
kitchen Room / Luminaire parts list
2 PiecesPHILIPS FBS285/218 NORMALSee our luminaire
Article No.:catalog for an image of
Luminous flux (Luminaire): 1356 lmthe luminaire.
Luminous flux (Lamps): 2400 lm
Luminaire Wattage: 48.0 W
Luminaire classification according to CIE: 100
CIE flux code: 56 89 98 100 57
Fitting: 2 x PL L 18W (Correction Factor 1.000).
PHILIPS FBS285/218 NORMAL / Luminaire Data Sheet
kitchen Room
See our luminaire catalog for an image of the luminaire.
Luminaire classification according to CIE: 100CIE flux code: 56 89 98 100 57
Luminous emittance 1:
Luminous emittance 1:
PHILIPS FBS285/218 NORMAL / LDC (Polar)
Luminaire: PHILIPS FBS285/218 NORMAL Lamps: 2 x PL L 18W
PHILIPS FBS285/218 NORMAL / LDC (Linear)
Luminaire: PHILIPS FBS285/218 NORMAL Lamps: 2 x PL L 18W
PHILIPS FBS285/218 NORMAL / UGR-Table
Luminaire: PHILIPS FBS285/218 NORMAL Lamps: 2 x PL L 18W
The UGR values have been calculated according to CIE Publ. 117 Spacing-to-Height-Ratio = 0.25.
Height of Room: 3.000 m, Mounting Height: 3.000 m, Light loss factor:0.67
Values in Lux, Scale 1:39
Surface [%]Eav [lx]Emin [lx]Emax [lx]u0
Workplane/108301290.277
Floor30513.98860.078
Ceiling322519350.764
Walls (4)32623.63154/
Workplane:Height:
0.760 m
Grid:Boundary Zone:128 x 128 Points0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.710, Ceiling / Working Plane: 0.234.
Luminaire Parts List
No.PiecesDesignation (Correction Factor) (Luminaire) [lm] (Lamps) [lm]P [W]
12PHILIPS FBS285/218 NORMAL (1.000)1356240048.0
Total: 2712Total: 480096.0
Specific connected load: 16.00 W/m = 14.86 W/m/100 lx (Ground area: 6.00 m)
Room 1 / Luminaire parts list
2 PiecesPHILIPS FBS285/218 NORMALSee our luminaire
Article No.:catalog for an image of
Luminous flux (Luminaire): 1356 lmthe luminaire.
Luminous flux (Lamps): 2400 lm
Luminaire Wattage: 48.0 W
Luminaire classification according to CIE: 100
CIE flux code: 56 89 98 100 57
Fitting: 2 x PL L 18W (Correction Factor 1.000).
Room 1 / Photometric Results
Total Luminous Flux: 2712 lm Total Load: 96.0 W Light loss factor: 0.67Boundary Zone: 0.000 m
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m]Workplanedirect86indirect21total108//
Calculation Surface 29022113//
Floor391251304.88
Ceiling0.002525322.57
Wall 1422163326.38
Wall 2491967326.83
Wall 3311849324.98
Wall 4491867326.81
Uniformity on the working plane u0: 0.277 (1:4)Emin / Emax: 0.232 (1:4)
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.710, Ceiling / Working Plane: 0.234. Specific connected load: 16.00 W/m = 14.86 W/m/100 lx (Ground area: 6.00 m)
Room 1 / 3D Rendering
Room 1 / Calculation Surface 2 / Isolines (E, Perpendicular)
Position of surface in room: Marked point:(-0.008 m, -0.002 m, 0.760 m)
Values in Lux, Scale 1 : 22
Grid: 32 x 32 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax113 83 129 0.739 0.645
Room 1 / Calculation Surface 2 / Value Chart (E, Perpendicular)
Not all calculated values could be displayed. Position of surface in room:Marked point:(-0.008 m, -0.002 m, 0.760 m)
Values in Lux, Scale 1 : 22
Grid: 32 x 32 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax113 83 129 0.739 0.645