![Page 1: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/1.jpg)
J 5A Molar Volume Lab
Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP.
![Page 2: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/2.jpg)
Materials NeededEudiometer
400 ml beaker
Ring stand
Buret clamp
Two hole rubber stopper
Copper wire
![Page 3: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/3.jpg)
Chemicals Needed
Magnesium ribbon, 3.5 – 4.0 cm length
6 M Hydrochloric Acid
![Page 4: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/4.jpg)
Read the procedure. Assemble all equipment.
Copper Wire
Magnesium ribbon
![Page 5: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/5.jpg)
Measure the magnesium ribbon.
Magnesium ribbon
![Page 6: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/6.jpg)
Use an analytical balance to get the mass of the magnesium ribbon.
Magnesium
![Page 7: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/7.jpg)
Pour 10 ml of 6M HCl directly into the eudiometer. Use the graduations on eudiometer to measure.
![Page 8: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/8.jpg)
Fill the eudiometer all the way to the brim with distilled water.
![Page 9: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/9.jpg)
Curl the magnesium ribbon and secure to the copper wire.
![Page 10: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/10.jpg)
The magnesium is attached to the copper on the rubber stopper.
Magnesium
![Page 11: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/11.jpg)
Magnesium ribbon
The rubber stopper is placed in the end of the eudiometer.
![Page 12: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/12.jpg)
The eudiometer is inverted in a beaker of water.
![Page 13: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/13.jpg)
Allow the magnesium ribbon and the HCl to react in the eudiometer until the reaction is complete.
![Page 14: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/14.jpg)
Bubbles begin to form at the magnesium ribbon.
Bubbles
![Page 15: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/15.jpg)
Increased Bubbles
As the reaction advances the bubbles become more intense.
![Page 16: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/16.jpg)
Pocket of Gas
As gas forms, the water is pushed out of the eudiometer through the holes in the rubber stopper.
![Page 17: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/17.jpg)
Read the ml
This is the amount of gas that has been collected in the eudiometer.
![Page 18: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/18.jpg)
Place the eudiometer in a large graduated cylinder filled with water.
![Page 19: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/19.jpg)
Keep one finger over the holes in the rubber stopper when placing the eudiometer in the graduated cylinder.
![Page 20: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/20.jpg)
Level inside tube
Level inside cylinder
Make the water level inside tube be on the same level as the water level in the graduated cylinder.
![Page 21: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/21.jpg)
The two levels are the same for the final reading.
![Page 22: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/22.jpg)
Final reading for the volume of the gas in the eudiometer.
Final reading
![Page 23: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/23.jpg)
Read the barometric pressure
Mercury level
![Page 24: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/24.jpg)
700 mmHg
800 mmHg
Level of mercury
![Page 25: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/25.jpg)
700 mmHg
54 mmHg
![Page 26: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/26.jpg)
![Page 27: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/27.jpg)
Take the reading on the thermometer.
![Page 28: J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP](https://reader036.vdocuments.us/reader036/viewer/2022062422/56649ece5503460f94bdb371/html5/thumbnails/28.jpg)
Final CalculationsRead the volume of the gas collected in the eudiometer and record in the data table.
Record the barometric pressure.
Record the room temperature.
Determine the water vapor pressure using a water vapor pressure table.