Jan.2011 International Catalogue 2011
S
Delixi Electric: Who are we Reliable Quality
A global company at your service
A reliable company serving you with reliable product
Delixi was founded in 1984 in Zhejiang province with sales over 1.5BM€,employing more than 15000 people.
Delixi created an international Joint Venture in November 2007,named Delixi Electric Ltd., in order to serve you
worldwide,with core LV products having the right quality at the right price.
Our products are designed for Residential/Building/Energy/infrastructure and Industrial markets.Delixi Electric
employs 5200 people world wide.
Dedicated R&D center
International quality control of suppliers
International quality control of plants
Fully automatized distribution center
Network of recognized 600 distributors world wide
Ⅰ
Delixi Electric: Who are we Reliable Quality
A global company at your service
A reliable company serving you with reliable product
Delixi was founded in 1984 in Zhejiang province with sales over 1.5BM€,employing more than 15000 people.
Delixi created an international Joint Venture in November 2007,named Delixi Electric Ltd., in order to serve you
worldwide,with core LV products having the right quality at the right price.
Our products are designed for Residential/Building/Energy/infrastructure and Industrial markets.Delixi Electric
employs 5200 people world wide.
Dedicated R&D center
International quality control of suppliers
International quality control of plants
Fully automatized distribution center
Network of recognized 600 distributors world wide
For more details, please contact your local Delixi Electrc Company.
Ⅱ
Ⅲ
1
Contents
Miniature Circuit Breakers&Switch Disconnectors
Residual Current Devices
Control Devices Surge Protective Devices
Distribution BoxAccessories for MCB&RCBO
3-18 19-32 33-36 37-40 41-42 43-47
Molded Case Circuit Breaker
Air Circuit Breaker48-63 64-82
Current Transformer Meter Digital Time Switch Voltage Stabilizer148-150 151-163 164-167 168-174
Din-railIndustrial Plug& Socket
Fuse Cable ConnectorControl Signal Copper Terminal Block Series
175-202 203-208 210-215 216-220 221209
Contactor&Thermal Overload Relay
Definite-purpose Contactors
Relays86-127 128-134 135-146
Pow
er Energy
Distribution
Low-voltage
Managem
entFinal D
istributionD
istribution
Low-voltage
Protection
Motor C
ontrol &
Managem
entP
ower E
nergy C
omponents
Industrial Control
2
Final Distribution
Contents
Final Distribution
s
Accessories for MCB&RCBO
Control Devices
Surge Protective Devices
CDB6 18mm Miniature Circuit Breaker
CDB6s 18mm Miniature Circuit Breaker
CDB2 27mm Miniature Circuit Breaker
CDB3 Phase-neutral Circuit Breaker
CDB5 Switch Disconnector
CDB6LE Residual Current Operated Circuit Breaker
CDB6v Residual Current Protection Module
CDB2LE Residual Current Operated Circuit Breaker
CDB3LE Residual Current Operated Circuit Breaker
CDL7 Electromagnetic Type Residual Current Switch
CDCH8 Modular Contactor
CDRT8 Time Relay
CDY1 Surge Protective Devices
CDPZ50 Series
JXF
SD,OF,MX+OF
Busbar
1~5
1~5
Distribution Box
Power Distribution Box
Miniature Circuit Breaker & Switch Disconnector
Residual Current Devices
Lighting Distribution Box
4
8
12
15
17
20
23
26
29
31
33
36
37
39
41
43
45
3-18
19-32
33-36
37-40
41-42
43-47
3
Final Distribution
18mm MCB 27mm MCB
S
In: 1-63AA
CDB2
In: 63-125ABreaking Capacity: 10kA
CDB6
In: 1-63ABreaking Capacity: 3/4.5 kA
18mm 1P+N MCB
CDB3
In: 6-32ABreaking Capacity: 3kA
CDB5
In: 20-100A
Switch Disconnectors
Accessories page** *
MX+OF SD OF
Miniature Circuit Breaker & Switch Disconnectors Product Overview
CDB6s
Breaking Capacity: 4.5/6 kA
4 8 12
15 17
33
4
Final Distribution
Function
1361016202532405063
22222222222
1361016202532405063
44444444444
CDB6a1D1CDB6a1D3CDB6a1D6CDB6a1D10CDB6a1D16CDB6a1D20CDB6a1D25CDB6a1D32CDB6a1D40CDB6a1D50CDB6a1D63
CDB6a2D1CDB6a2D3CDB6a2D6CDB6a2D10CDB6a2D16CDB6a2D20CDB6a2D25CDB6a2D32CDB6a2D40CDB6a2D50CDB6a2D63
CDB6a1B1CDB6a1B3CDB6a1B6CDB6a1B10CDB6a1B16CDB6a1B20CDB6a1B25CDB6a1B32CDB6a1B40CDB6a1B50CDB6a1B63
CDB6a2B1CDB6a2B3CDB6a2B6CDB6a2B10CDB6a2B16CDB6a2B20CDB6a2B25CDB6a2B32CDB6a2B40CDB6a2B50CDB6a2B63
CDB6a1C1CDB6a1C3CDB6a1C6CDB6a1C10CDB6a1C16CDB6a1C20CDB6a1C25CDB6a1C32CDB6a1C40CDB6a1C50CDB6a1C63
CDB6a2C1CDB6a2C3CDB6a2C6CDB6a2C10CDB6a2C16CDB6a2C20CDB6a2C25CDB6a2C32CDB6a2C40CDB6a2C50CDB6a2C63
3
CDB6L1D1CDB6L1D3CDB6L1D6CDB6L1D10CDB6L1D16CDB6L1D20CDB6L1D25CDB6L1D32CDB6L1D40CDB6L1D50CDB6L1D63
CDB6L1C1CDB6L1C3CDB6L1C6CDB6L1C10CDB6L1C16CDB6L1C20CDB6L1C25CDB6L1C32CDB6L1C40CDB6L1C50CDB6L1C63
CDB6L1B1CDB6L1B3CDB6L1B6CDB6L1B10CDB6L1B16CDB6L1B20CDB6L1B25CDB6L1B32CDB6L1B40CDB6L1B50CDB6L1B63
1361016202532405063
22222222222
4.5
2P 3
TypeRating(A) Width
D curve
Reference
C curveB curve
Breaking Capacity(kA)
CDB6 18mm Miniature Circuit BreakerStandard: IEC 60898-1 Trip Curve: B, C and D curvesBreaking Capacity: 3000 /4500A
Order Information
RoHS
Note: Width refers to multiple of 9 mm.
CDB6 miniature circuit breaker combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
1P
5
Final Distribution
Order Information
CDB6 18mm Miniature Circuit BreakerStandard: IEC 60898-1 Trip Curve: B, C and D curvesBreaking Capacity: 3000 /4500A
CDB6L2D1CDB6L2D3CDB6L2D6CDB6L2D10CDB6L2D16CDB6L2D20CDB6L2D25CDB6L2D32CDB6L2D40CDB6L2D50CDB6L2D63
CDB6L2C1CDB6L2C3CDB6L2C6CDB6L2C10CDB6L2C16CDB6L2C20CDB6L2C25CDB6L2C32CDB6L2C40CDB6L2C50CDB6L2C63
CDB6L2B1CDB6L2B3CDB6L2B6CDB6L2B10CDB6L2B16CDB6L2B20CDB6L2B25CDB6L2B32CDB6L2B40CDB6L2B50CDB6L2B63
1361016202532405063
44444444444
4.5
Note: Width refers to multiple of 9 mm.
RoHS
1361016202532405063
66666666666
CDB6a3D1CDB6a3D3CDB6a3D6CDB6a3D10CDB6a3D16CDB6a3D20CDB6a3D25CDB6a3D32CDB6a3D40CDB6a3D50CDB6a3D63
CDB6a3B1CDB6a3B3CDB6a3B6CDB6a3B10CDB6a3B16CDB6a3B20CDB6a3B25CDB6a3B32CDB6a3B40CDB6a3B50CDB6a3B63
CDB6a3C1CDB6a3C3CDB6a3C6CDB6a3C10CDB6a3C16CDB6a3C20CDB6a3C25CDB6a3C32CDB6a3C40CDB6a3C50CDB6a3C63
3
CDB6L3D1CDB6L3D3CDB6L3D6CDB6L3D10CDB6L3D16CDB6L3D20CDB6L3D25CDB6L3D32CDB6L3D40CDB6L3D50CDB6L3D63
CDB6L3C1CDB6L3C3CDB6L3C6CDB6L3C10CDB6L3C16CDB6L3C20CDB6L3C25CDB6L3C32CDB6L3C40CDB6L3C50CDB6L3C63
CDB6L3B1CDB6L3B3CDB6L3B6CDB6L3B10CDB6L3B16CDB6L3B20CDB6L3B25CDB6L3B32CDB6L3B40CDB6L3B50CDB6L3B63
1361016202532405063
66666666666
4.5
CDB6a4D1CDB6a4D3CDB6a4D6CDB6a4D10CDB6a4D16CDB6a4D20CDB6a4D25CDB6a4D32CDB6a4D40CDB6a4D50CDB6a4D63
CDB6a4B1CDB6a4B3CDB6a4B6CDB6a4B10CDB6a4B16CDB6a4B20CDB6a4B25CDB6a4B32CDB6a4B40CDB6a4B50CDB6a4B63
CDB6a4C1CDB6a4C3CDB6a4C6CDB6a4C10CDB6a4C16CDB6a4C20CDB6a4C25CDB6a4C32CDB6a4C40CDB6a4C50CDB6a4C63
1361016202532405063
88888888888
3
TypeRating(A) Width
D curve
Reference
C curve
Breaking Capacity(kA) B curve
3P
4P
6
Final Distribution
CDB6 18mm Miniature Circuit BreakerStandard: IEC 60898-1 Trip Curve: B, C and D curvesBreaking Capacity: 3000 /4500A
RoHS
Technical Data
1-63 230/400400
B Curve:the magnetic release operates between 3 and 5 In
C Curve:the magnetic release operates between 5 and 10 In
D Curve:the magnetic release operates between 10 and 14 In
Up to 25mm cables2
1-63 M5 2.5 4.5
MCB CDB6 18mm Circuit Breaker
Breaking Capacity Icn
Tripping Curve(see following tripping curve pictures)
Protection DegreeTropicalizationAmbient Temperature
4000 times10000 times2treatment 2-5℃~+40℃
MechanicalFeatures
Connection
Installation
35mm Din-railMounting
AccessoriesOFSDMX+OF
Contact AccessoryFault-indicating AccessoryShunt -trip release
ElectricalFeatures
Rate current(A) Poles Voltage(V) Breaking capactiy Icn(KA)
RateCurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
StandardCertificationPolesRated Current InRated Voltage UeInsulation Voltage Ui
IEC60898-1
1,3,6,10,16,20,25,32,40,50,63 A230/400V AC500V
1-4P
Electrical DurabilityMechanical Durability
CDB6L4D1CDB6L4D3CDB6L4D6CDB6L4D10CDB6L4D16CDB6L4D20CDB6L4D25CDB6L4D32CDB6L4D40CDB6L4D50CDB6L4D63
CDB6L4C1CDB6L4C3CDB6L4C6CDB6L4C10CDB6L4C16CDB6L4C20CDB6L4C25CDB6L4C32CDB6L4C40CDB6L4C50CDB6L4C63
CDB6L4B1CDB6L4B3CDB6L4B6CDB6L4B10CDB6L4B16CDB6L4B20CDB6L4B25CDB6L4B32CDB6L4B40CDB6L4B50CDB6L4B63
1361016202532405063
88888888888
4.5
Note: Width refers to multiple of 9 mm.
TypeRating(A) Width
D curve
Reference
C curve
Breaking Capacity(kA) B curve
Order Information
CB, CE, RoHS
1P 2P, 3P, 4P
~
3/4.53/4.5
7
Final Distribution
CDB6 Miniature Circuit Breaker Tripping Curve
CDB6 18mm Miniature Circuit BreakerStandard: IEC 60898-1 Trip Curve: B, C and D curvesBreaking Capacity: 3000 /4500A
Overall Dimensions
The Sketch Map of Installation with BreakersAccessory
SD OF CDB6 MX+OF
RoHS
8
Final Distribution
Function CDB6s miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
CDB6s 18mm Miniature Circuit BreakerStandard: IEC 60898-1Trip Curve: B, C and D curvesBreaking Capacity: 4500 /6000A
Order Information
1P
2P
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
CDB6s1B1
CDB6s1B2
CDB6s1B3
CDB6s1B4
CDB6s1B5
CDB6s1B6
CDB6s1B8
CDB6s1B10
CDB6s1B13
CDB6s1B16
CDB6s1B20
CDB6s1B25
CDB6s1B32
CDB6s1B40
CDB6s1B50
CDB6s1B63
Type
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
Rating(A)
WidthD curveC curve
ReferenceB curve
CDB6s2B1
CDB6s2B2
CDB6s2B3
CDB6s2B4
CDB6s2B5
CDB6s2B6
CDB6s2B8
CDB6s2B10
CDB6s2B13
CDB6s2B16
CDB6s2B20
CDB6s2B25
CDB6s2B32
CDB6s2B40
CDB6s2B50
CDB6s2B63
CDB6s1C1
CDB6s1C2
CDB6s1C3
CDB6s1C4
CDB6s1C5
CDB6s1C6
CDB6s1C8
CDB6s1C10
CDB6s1C13
CDB6s1C16
CDB6s1C20
CDB6s1C25
CDB6s1C32
CDB6s1C40
CDB6s1C50
CDB6s1C63
CDB6s2C1
CDB6s2C2
CDB6s2C3
CDB6s2C4
CDB6s2C5
CDB6s2C6
CDB6s2C8
CDB6s2C10
CDB6s2C13
CDB6s2C16
CDB6s2C20
CDB6s2C25
CDB6s2C32
CDB6s2C40
CDB6s2C50
CDB6s2C63
CDB6s1D1
CDB6s1D2
CDB6s1D3
CDB6s1D4
CDB6s1D5
CDB6s1D6
CDB6s1D8
CDB6s1D10
CDB6s1D13
CDB6s1D16
CDB6s1D20
CDB6s1D25
CDB6s1D32
CDB6s1D40
CDB6s1D50
CDB6s1D63
CDB6s2D1
CDB6s2D2
CDB6s2D3
CDB6s2D4
CDB6s2D5
CDB6s2D6
CDB6s2D8
CDB6s2D10
CDB6s2D13
CDB6s2D16
CDB6s2D20
CDB6s2D25
CDB6s2D32
CDB6s2D40
CDB6s2D50
CDB6s2D63
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4Note: Width refers to multiple of 9 mm.
9
Final Distribution
CDB6s 18mm Miniature Circuit Breaker
Order Information
Standard: IEC 60898-1 Trip Curve: B, C and D curvesBreaking Capacity: 4500 /6000A
3P
4P
Type WidthRating(A)
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
D curveC curve
CDB6s3B1
CDB6s3B2
CDB6s3B3
CDB6s3B4
CDB6s3B5
CDB6s3B6
CDB6s3B8
CDB6s3B10
CDB6s3B13
CDB6s3B16
CDB6s3B20
CDB6s3B25
CDB6s3B32
CDB6s3B40
CDB6s3B50
CDB6s3B63
CDB6s4B1
CDB6s4B2
CDB6s4B3
CDB6s4B4
CDB6s4B5
CDB6s4B6
CDB6s4B8
CDB6s4B10
CDB6s4B13
CDB6s4B16
CDB6s4B20
CDB6s4B25
CDB6s4B32
CDB6s4B40
CDB6s4B50
CDB6s4B63
CDB6s3C1
CDB6s3C2
CDB6s3C3
CDB6s3C4
CDB6s3C5
CDB6s3C6
CDB6s3C8
CDB6s3C10
CDB6s3C13
CDB6s3C16
CDB6s3C20
CDB6s3C25
CDB6s3C32
CDB6s3C40
CDB6s3C50
CDB6s3C63
CDB6s3D1
CDB6s3D2
CDB6s3D3
CDB6s3D4
CDB6s3D5
CDB6s3D6
CDB6s3D8
CDB6s3D10
CDB6s3D13
CDB6s3D16
CDB6s3D20
CDB6s3D25
CDB6s3D32
CDB6s3D40
CDB6s3D50
CDB6s3D63
CDB6s4C1
CDB6s4C2
CDB6s4C3
CDB6s4C4
CDB6s4C5
CDB6s4C6
CDB6s4C8
CDB6s4C10
CDB6s4C13
CDB6s4C16
CDB6s4C20
CDB6s4C25
CDB6s4C32
CDB6s4C40
CDB6s4C50
CDB6s4C63
CDB6s4D1
CDB6s4D2
CDB6s4D3
CDB6s4D4
CDB6s4D5
CDB6s4D6
CDB6s4D8
CDB6s4D10
CDB6s4D13
CDB6s4D16
CDB6s4D20
CDB6s4D25
CDB6s4D32
CDB6s4D40
CDB6s4D50
CDB6s4D63
1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Note: Width refers to multiple of 9 mm.
ReferenceB curve
10
Final Distribution
Ratecurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
CDB6s 18mm Miniature Circuit BreakerStandard: IEC 60898-1Trip Curve: B, C and D curvesBreaking Capacity: 4500 /6000A
Technical Data
MCB CDB6s 18mm Circuit Breaker
Standard
4000 times
10000 times
2
treatment 2
-5℃~ 40℃
Up to 25mm cables2
1-63 M5 2.5 4.5
35mm Din-railMounting
Connection
MechanicalFeatures
IEC 60898-1
KEMA CB CE RoHS
500V AC
Breaking Capacity Icn
Certitication
poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
B curve;the magnetic release operates between 3 and 5 InC curve;the magnetic release operates between 5 and 10 InD curve;the magnetic release operates between 10 and 14 In
Tripping Curve ( see following tripping curve pictures)
Ambient Temperture
Tropicalization
Protection Degree
AccessoriesContact Accessory OF
SD
MX+OF
Fault-indicating Accessory
Ratecurrent(A)
Poles VoltageElectricalFeatures
1-4P
230/400V AC
Electrical Durability
Mechanical Durability
Installation
Shunt-trip Release
1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63
6
4.5
4.5
1-40
50,63
1-63
Type
B,C
B,C
D
1P 230/400 2P, 3P, 4P 400
1P 230/400 2P, 3P, 4P 4001P 230/400 2P, 3P, 4P 400
Breaking capacity lcn(kA)
~ +
(V)
11
Final Distribution
CDB6s 18mm Miniature Circuit BreakerStandard: IEC 60898-1Trip Curve: B, C and D curvesBreaking Capacity: 4500 /6000A
Tripping Curves
Overall Dimensions
Accessory
:67.21–0.43
88 m
ax
SD OF MX+OFCDB6s
Unit: mm
1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63
12
Final Distribution
Function
6380100125
6666
2P CDB2H2D63CDB2H2D80CDB2H2D100CDB2H2D125
CDB2H2C63CDB2H2C80CDB2H2C100CDB2H2C125
6380100125
9999
3P CDB2H3D63CDB2H3D80CDB2H3D100CDB2H3D125
CDB2H3C63CDB2H3C80CDB2H3C100CDB2H3C125
6380100125
12121212
4P CDB2H4C63CDB2H4C80CDB2H4C100CDB2H4C125
CDB2H4D63CDB2H4D80CDB2H4D100CDB2H4D125
Type Rating(A)
Width(in mod.of 9mm)
ReferenceC curve D curve
6380100125
3333
CDB2H1D63CDB2H1D80CDB2H1D100CDB2H1D125
1P CDB2H1C63CDB2H1C80CDB2H1C100CDB2H1C125
Order Information
CDB2 miniature circuit breaker combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
CDB2 27mm Miniature Circuit BreakerStandard: IEC 60947-2Trip Curve: C and D curvesBreaking Capacity: 10000A
13
Final Distribution
Technical Data
CDB2 27mm Miniature Circuit BreakerStandard: IEC 60947-2Trip Curve: C and D curvesBreaking Capacity: 10000A
63~125 1P2P,3P,4P
230400
1010
Breaking Capacity Icn
C curve the magnetic release operates between 5 and 10 InD curve the magnetic release operates between 10 and 14 In
CDB2 27mm Circuit Breaker
Standard
Certification
IEC60947-2
Poles
230/400V AC
63,80,100,125ARated Current In
Rated Voltage Ue
500VInsulation Voltage Ui
Rating(A)
Poles Voltage(V)
Breaking capacity(kA)
Tripping Curve (see following tripping curve pictures)
Protection Degree
Tropicalization
Ambient Temperature
Up to 50mm cables2
-5℃~+40℃
treatment 2
2
Ratecurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
63-125 M7 4 5.5
35mm Din-rail
Shunt-trip Release:
OF
MX+OF
Electrical Durability
Mechanical Durability
Contact Accessory:
1-4P
~
Mounting
Accessories
Connection
MechanicalFeatures
Installation
ElectricalFeatures
MCB
CB, SEMKO, CE
14
Final Distribution
CDB2 27mm Miniature Circuit BreakerStandard: IEC 60947-2Trip Curve: C and D curvesBreaking Capacity: 10000A
MX+OF OF CDB2
Tripping Curves
Overall Dimensions
Accessories
15
Final Distribution
Function
IEC60898-1
CE
1P+N
6,10,16,20,25,32A
230V AC
500V
3KABreaking Capacity Icn
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10In
-
Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Ratecurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
6-32 M4 2 3
ElectricalFeatures
CDB3a5C6
CDB3a5C10
CDB3a5C16
CDB3a5C20
CDB3a5C25
CDB3a5C32
2
2
2
2
2
2
6
10
16
20
25
32
1P+N
CDB3 phase-neutral circuit breakers combine the following functions:Protection of circuits against overload currentsProtection of circuits against short-circuit currentsControlIsolation
Order Information
Technical Data
CDB3 Phase-neutral Circuit BreakerStandard: IEC 60898-1Trip Curve: C curvesBreaking Capacity: 3000A
2
treatment 2
5℃~+40℃
Protection Degree
Ambient Temperature
Tropicalization
4000 times
16000 times
Electrical Durability
Mechanical Durability
Up to 10mm cables2
35mm Din-rail
Mechanical Features
MCB
Connection
Installation
Mounting
CDB3 18mm Circuit Breaker
16
Final Distribution
CDB3 Phase-neutral Circuit BreakerStandard: IEC 60898-1Trip Curve: C curvesBreaking Capacity: 3000A
Overall Dimensions
Tripping Curves
5
2
1
10000
5000
20001h
1000500
200
100
50
20
10
0.5
0.2
0.1
0.05
0.005
0.02
0.002
0.01
0.0010.5 1 2 3 4 5 7 10 20 30 50 100 20070
17
Final Distribution
Type Voltage(V)
1P 230
3P 400
4P 400
2P
Width(in mod.of 9mm)2222
6666
8888
4444
400
Reference
CDB5120CDB5132CDB5163CDB51100
CDB5320CDB5332CDB5363CDB53100
CDB5420CDB5432CDB5463CDB54100
CDB5220CDB5232CDB5263CDB52100
Rating(A)203263100
203263100
203263100
203263100
Order Information
Standard: IEC 60947-3
CDB5 Switch Disconnector
CDB5 switch disconnectors combine the following functions: Making and breaking normal load circuits Isolation
combine the following functions:Function
18
Final Distribution
Standard: IEC 60947-3
CDB5 Switch Disconnector
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Ratecurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
20-100 M7 4 5.5
l
CDB5 Switch Disconnector
Standard
Rated Short-circuitMaking Capacity
Capacity for 1s
Protection Degree
Ambient Temperature
Tropicalization
Storage Temperature
Up to 50mm cables2
35mm Din-rai
Overall Dimensions
Technical Data
Electrical Durability
Mechanical Durability
2
-5℃~+40℃
treatment 2
-25℃~+55℃
1500 times
8500 times
Switch Disconnector
ElectricalFeatures
20,32,63,100A
500V
IEC60947-3
1066A(Ie:20~63A)
1692A(Ie:100A), Peak current
756A(Ie:20~63A)
1200A(Ie:100A),1s
1-4P
230/400V AC
Short-time Withstand
Connection
Installation
Mounting
Mechanical Features
19
Final Distribution
Sensitivity: 30,50,100,200,300mAIn: 6-60ABreaking Capacity: 3kA
CDB6LE
CDL7
CDB6v
18mm RCBO
CDB3LE
Sensitivity: 30mAIn: 6-40ABreaking Capacity: 4.5kAPoles: 1P+N
Phase-neutral RCBO
Add-on RCD
Sensitivity: 30,100,300mAIn: 63-100ABreaking Capacity: 10kA
CDB2LE
27mm RCBO
RCCB
OverviewResidual Current Devices
Poles: 1P+N, 2P, 3P, 3P+N, 4P
Sensitivity: 30,100,300mAIn: V32A, V63APoles: 1P+N, 2P, 3P, 3P+N, 4P
Poles: 1P+N, 2P, 3P, 3P+N, 4P
20 23
26 29
31
In: 25-100APoles: 2P,4P
Sensitivity:10,30,100,300mA
20
Final Distribution
Function CDB6LE electronic type residual current operated circuit breakers combine the following functions: Overload protection Protection against short-circuit current Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation
CDB6LE Residual Current Operated Circuit Breaker
61016202532405060
400 30 111111111111141414
61016202532405060
400 30 101010101010121212
CDB6LEa3C6SCDB6LEa3C10SCDB6LEa3C16SCDB6LEa3C20SCDB6LEa3C25SCDB6LEa3C32SCDB6LEa3C40SCDB6LEa3C50SCDB6LEa3C60S
CDB6LEa3D6SCDB6LEa3D10SCDB6LEa3D16SCDB6LEa3D20SCDB6LEa3D25SCDB6LEa3D32SCDB6LEa3D40SCDB6LEa3D50SCDB6LEa3D60S
777777888
CDB6LEa2C6SCDB6LEa2C10SCDB6LEa2C16SCDB6LEa2C20SCDB6LEa2C25SCDB6LEa2C32SCDB6LEa2C40SCDB6LEa2C50SCDB6LEa2C60S
230 30 61016202532405060
230
3P+N
3P
2P
1P+N 30 555555666
CDB6LEa1C6SCDB6LEa1C10SCDB6LEa1C16SCDB6LEa1C20SCDB6LEa1C25SCDB6LEa1C32SCDB6LEa1C40SCDB6LEa1C50SCDB6LEa1C60S
CDB6LEa1D6SCDB6LEa1D10SCDB6LEa1D16SCDB6LEa1D20SCDB6LEa1D25SCDB6LEa1D32SCDB6LEa1D40SCDB6LEa1D50SCDB6LEa1D60S
61016202532405060
CDB6LEa6C6SCDB6LEa6C10SCDB6LEa6C16SCDB6LEa6C20SCDB6LEa6C25SCDB6LEa6C32SCDB6LEa6C40SCDB6LEa6C50SCDB6LEa6C60S
CDB6LEa6D6SCDB6LEa6D10SCDB6LEa6D16SCDB6LEa6D20SCDB6LEa6D25SCDB6LEa6D32SCDB6LEa6D40SCDB6LEa6D50SCDB6LEa6D60S
CDB6LEa2D6SCDB6LEa2D10SCDB6LEa2D16SCDB6LEa2D20SCDB6LEa2D25SCDB6LEa2D32SCDB6LEa2D40SCDB6LEa2D50SCDB6LEa2D60S
Type Width ReferenceC curve D curve
Voltage(V)
Sensitivity(mA)
Rating(A)
Order Information
Note: 1. Width refers to multiple of 9 mm. 2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with "W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T".
Standard: IEC 61009-1Electronic type: ACBreaking Capacity: 3000ASensitivity: 30,50,100,200,300mA
21
Final Distribution
Type Width ReferenceC curve D curve
Voltage(V)
Sensitivity(mA)
Rating(A)
Order Information
4004P 30 CDB6LEa4C6SCDB6LEa4C10SCDB6LEa4C16SCDB6LEa4C20SCDB6LEa4C25SCDB6LEa4C32SCDB6LEa4C40SCDB6LEa4C50SCDB6LEa4C60S
CDB6LEa4D6SCDB6LEa4D10SCDB6LEa4D16SCDB6LEa4D20SCDB6LEa4D25SCDB6LEa4D32SCDB6LEa4D40SCDB6LEa4D50SCDB6LEa4D60S
61016202532405060
131313131313161616
CDB6LE Residual Current Operated Circuit BreakerStandard: IEC 61009-1Electronic type: ACBreaking Capacity: 3000ASensitivity: 30,50,100,200,300mA
Note: 1. Width refers to multiple of 9 mm. 2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with "W",100mA is marked with "Y",200mA is marked with "R",300mA is marked with "T".
Ratecurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
6-32 M4 2.0 3.040-60 M5 2.5 4.5
RCBO CDB6LE Residual Current Operated Circuit Breaker
AC
1P+N,2P,3P,3P+N,4P
6,10,16,20,25,32,40,50,60A
500V
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Standard
3KABreaking Capacity
Sensitivity 30,50,100,200,300mA
Tripping Curve(see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10D curve:the magnetic release operates between 10 and 14
Protection DegreeTropicalizationAmbient Temperature
Contact Accessory:Fault-indicating Accessory:
OF
SD
ElectricalFeatures
35mm Din-rail
Technical Data
2000 times2000 times2treatment 2 -5℃~+40℃
6-32A,Up to 16mm2 2 cables, 40-60A,Up to 25mm cables
230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P
Electrical DurabilityMechanical Durability
Installation
Mounting
Accessories
Connection
Mechanical Features
CDB6LE Residual Current Operated Circuit Breaker
IEC 61009-1
22
Final Distribution
CDB6LE Residual Current Operated Circuit BreakerStandard: IEC 61009-1Electronic type: ACBreaking Capacity: 3000ASensitivity: 30,50,100,200,300mA
Tripping Curves
Accessories
CDB6LEOFSD
Overall Dimensions
23
Final Distribution
Order Information
Function CDB6v can be assembled with CDB6s to be residual current breaker overcurrent Protection of persons against indirect contacting Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products marked "G"
Note: Width refers to mutultiple of 9mm.
CDB6v Residual Current Protection Module Standard: IEC 61009-1Electronic type: ACSensitivity: 30,100,300mA
Frame Type Voltage(V)
Sensitivity(mA) Width Reference
V32 1P+N 230 30 5 CDB6v321N100 5 CDB6v321NR100300 5 CDB6v321NR300
2P 400 30 7 CDB6v322P 100 7 CDB6v322PR100
300 7 CDB6v322PR3003P 30 10 CDB6v323P
100 10 CDB6v323PR100300 10 CDB6v323PR300
3P+N 30 11 CDB6v323N100 11 CDB6v323NR100300 11 CDB6v323NR300
4P 30 13 CDB6v324P100 13 CDB6v324PR100300 13 CDB6v324PR300
V63 1P+N 230 30 6 CDB6v631N100 6 CDB6v631NR100300 6 CDB6v631NR300
2P 400 30 8 CDB6v632P100 8 CDB6v632PR100300 8 CDB6v632PR300
3P 30 12 CDB6v633P100 12 CDB6v633PR100300 12 CDB6v633PR300
3P+N 30 14 CDB6v633N100 14 CDB6v633NR100300 14 CDB6v633NR300
4P 30 16 CDB6v634P100 16 CDB6v634PR100300 16 CDB6v634PR300
CDB6LE Residual Current Operated Circuit Breaker
24
Final Distribution
Technical Data
CDB6v Residual Current Protection Module Standard: IEC 61009-1Electronic type: ACSensitivity: 30,100,300mA
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
RCD CDB6v Residual Current Protection Module
Rated Insulation Voltage
Breaking Capacity
Sensitivity
IEC61009-1
AC
V32 In≤32A V63 In≤63A
500V A
30,100,300mA
Tripping Indication
Manual control:allows for two kinds of resetCDB6v resets at the same time with breakerCDB6v resets before breaker
“G” products offer overvoltage protection
280V±5% AC,applicable toproducts with 1P+N and 2P
2000 times(In≤25A) 1000times(In>25A)
Protection Degree IP20
Tropicaliation treatrment 2
Ambient Temperature -5℃~+40℃
-Up to 16mm cables(V32)-Up to 25mm cables(V63)
Ratecurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
V32V63
M4M5
2.22.5
3.04.5
ElectricalFeatures
On CDB6v is a residual opening current indication, which distinguish residual current from other faults
2
2
after CDB6s assembled with reference to CDB6s parameters
Connection
Installation
1P+N, 2P, 3P, 3P+N, 4P
Manual Control
yElectrical Durabilit
Mechanical Durability 2000 times
~
230/400V AC
;
1000 times(In>25A)
Mechanical Features
25
Final Distribution
CDB6v Residual Current Protection Module Standard: IEC 61009-1Electronic type: ACSensitivity: 30,100,300mA
Overall Dimensions
Assembly
Protection of persons against indirect contacting Supplementary protection of persons against direct contacting Prevention of electric-caused fire Overvoltage protection by products marked“G”
+
45±0.32
63±0.37
90±0.5
99±0.5
117±0.57
V32
1P+N
2P
3P
3P+N
4P
Pole
54±0.37
72±0.43
108±0.57
126±0.64
144±0.72
V63
CDB6v can be assembled with CDB6s to be residual current breaker overcurrent
26
Final Distribution
RCBO CDB3LE Residual Current Operated Circuit Breaker
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10 In
Connection
Installation
Mounting
Mechanical Features
35mm Din-rail
Ratecurrent(A)
ScrewRated Torque(Nm)
Limiting Torque(Nm)
6-40 M5 2.5 4.5
Technical Data
IEC61009-1
AC
1P+N
6,10,16,20,25,32,40A
230V AC
500V
4.5KA
30mA
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity
Sensitivity
Electrical LifeMechanical LifeProtection DegreeTropicalizationAmbient Temperature
2Up to 16mm cables
Electrical Features
3P 638010063801006380100
303030100100100300300300
12 CDB2LEH3D63SCDB2LEH3D80SCDB2LEH3D100SCDB2LEH3D63YCDB2LEH3D80YCDB2LEH3D100YCDB2LEH3D63TCDB2LEH3D80TCDB2LEH3D100T
CDB2LEH3C63SCDB2LEH3C80SCDB2LEH3C100SCDB2LEH3C63YCDB2LEH3C80YCDB2LEH3C100YCDB2LEH3C63TCDB2LEH3C80TCDB2LEH3C100T
638010063801006380100
303030100100100300300300
6 CDB2LEH1D63SCDB2LEH1D80SCDB2LEH1D100SCDB2LEH1D63YCDB2LEH1D80YCDB2LEH1D100YCDB2LEH1D63TCDB2LEH1D80TCDB2LEH1D100T
CDB2LEH1C63SCDB2LEH1C80SCDB2LEH1C100SCDB2LEH1C63YCDB2LEH1C80YCDB2LEH1C100YCDB2LEH1C63TCDB2LEH1C80TCDB2LEH1C100T
1P+N
638010063801006380100
303030100100100300300300
9 CDB2LEH2D63SCDB2LEH2D80SCDB2LEH2D100SCDB2LEH2D63YCDB2LEH2D80YCDB2LEH2D100YCDB2LEH2D63TCDB2LEH2D80TCDB2LEH2D100T
CDB2LEH2C63SCDB2LEH2C80SCDB2LEH2C100SCDB2LEH2C63YCDB2LEH2C80YCDB2LEH2C100YCDB2LEH2C63TCDB2LEH2C80TCDB2LEH2C100T
2P
3P+N 638010063801006380100
303030100100100300300300
12 CDB2LEH6D63SCDB2LEH6D80SCDB2LEH6D100SCDB2LEH6D63YCDB2LEH6D80YCDB2LEH6D100YCDB2LEH6D63TCDB2LEH6D80TCDB2LEH6D100T
CDB2LEH6C63SCDB2LEH6C80SCDB2LEH6C100SCDB2LEH6C63YCDB2LEH6C80YCDB2LEH6C100YCDB2LEH6C63TCDB2LEH6C80TCDB2LEH6C100T
Type Width ReferenceC curve
Rating(A)
Sensitivity(mA) D curve
Order Information
Function CDB2LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Protection of electrical installations against insulation faults (fire hazard, etc) Isolation
CDB2LE Residual Current Operated Circuit BreakerStandard: IEC 60947-2Electronic type: ACBreaking Capacity: 10000ASensitivity: 30, 100, 300mA
Note: Width refers to multiple of 9mm .
27
Final Distribution
RCBO CDB3LE Residual Current Operated Circuit Breaker
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10 In
Connection
Installation
Mounting
Mechanical Features
35mm Din-rail
Ratecurrent(A)
ScrewRated Torque(Nm)
Limiting Torque(Nm)
6-40 M5 2.5 4.5
Technical Data
IEC61009-1
AC
1P+N
6,10,16,20,25,32,40A
230V AC
500V
4.5KA
30mA
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity
Sensitivity
Electrical LifeMechanical LifeProtection DegreeTropicalizationAmbient Temperature
2Up to 16mm cables
Electrical Features
CDB2LE Residual Current Operated Circuit Breaker
4P 638010063801006380100
303030100100100300300300
15 CDB2LEH4D63SCDB2LEH4D80SCDB2LEH4D100SCDB2LEH4D63YCDB2LEH4D80YCDB2LEH4D100YCDB2LEH4D63TCDB2LEH4D80TCDB2LEH4D100T
CDB2LEH4C63SCDB2LEH4C80SCDB2LEH4C100SCDB2LEH4C63YCDB2LEH4C80YCDB2LEH4C100YCDB2LEH4C63TCDB2LEH4C80TCDB2LEH4C100T
Note: Width refers to multiple of 9mm .
Technical Data
Contact Accessory:
Standard
Poles
Rated Current In
RCBO CDB2LE Residual Current Operated Circuit Breaker
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity
Sensitivity
IEC60947-2
AC
1P+N,2P,3P,3P+N,4P
63,80,100A
500V
10KA
30,100,300mA
Connection
Ratecurrent(A)
Screw Rated Torque(Nm)
Limiting Torque(Nm)
63-100 M7 4 5.5Installation
Electronic Type
Tripping Curve ( see following tripping curve pictures)
C curve:the magnetic release operated between 5 and 10 In
D curve:the magnetic release operated between 10 and 14 In
Protection Degree
Tropicalization
Ambient Temperature
8500 times
2
treatment 2
-5℃~+40℃
Accessories Shunt -trip Release:
OF
MX+OF
Up to 50mm cables2
1500 times
Mechanical Durability
Electrical Durability
Type Width ReferenceC curve
Rating(A)
Sensitivity(mA) D curve
Order Information
Standard: IEC 60947-2Electronic type: ACBreaking Capacity: 10000ASensitivity: 30, 100, 300mA
230V for 1P+N; 400V for 2P/3P/3P+N/4PElectrical Features
Mechanical Features
28
Final Distribution
CDB2LE Residual Current Operated Circuit Breaker
Overall Dimensions
Accessories
CDB2LEMX+OF OF
Standard: IEC 60947-2Electronic type: ACBreaking Capacity: 10000ASensitivity: 30, 100, 300mA
Tripping Curvee
29
Final Distribution
RCBO CDB3LE Residual Current Operated Circuit Breaker
Tripping Curve (see following tripping curve pictures)
C curve:the magnetic release operates between 5 and 10 In
Connection
Installation
Mounting 35mm Din-rail
Ratecurrent(A)
ScrewRated Torque(Nm)
Limiting Torque(Nm)
6-40 M5 2.5 4.5
IEC61009-1
AC
1P+N
6,10,16,20,25,32,40A
230V AC
500V
4.5KA
30mA
Standard
Electronic Type
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Breaking Capacity
Sensitivity
Protection DegreeTropicalizationAmbient Temperature
2000 times2000 times2treatment 2 -5℃~+40℃
2Up to 16mm cables
Function
CDB3LE Residual Current Operated Circuit BreakerStandard: IEC 61009-1Electronic type: ACBreaking Capacity: 4500ASensitivity: 30mA
CDB3LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc) Isolation
Type
1P+N
Width (mm)36
Rating(A)
6101620253240
CDB3LEL5C6SCDB3LEL5C10SCDB3LEL5C16SCDB3LEL5C20SCDB3LEL5C25SCDB3LEL5C32SCDB3LEL5C40S
Reference C curve
Order Information
Technical Data
Mechanical Features
Electrical Features
Electrical DurabilityMechanical Durability
30
Final Distribution
Overall Dimensions
Tripping Curve
CDB3LE Residual Current Operated Circuit BreakerStandard: IEC 61009-1Electronic type: ACBreaking Capacity: 4500ASensitivity: 30mA
31
Final Distribution
CDL7 electromagnetic type residual current switch combine the following functions: Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc)
CDL7 Electromagnetic Type Residual Current SwitchStandard: IEC 61008RCCB Type: A , ACSensitivity: 10, 30, 100, 300mA
Function
Order Information
10301003001030100300103010030030100300301003003010030030100300
42P
84P
CDL7210LCCDL7210SCCDL7210YCCDL7210TCCDL7216LCCDL7216SCCDL7216YCCDL7216TCCDL7225LCCDL7225SCCDL7225YCCDL7225TCCDL7240SCCDL7240YCCDL7240TCCDL7263SCCDL7263YCCDL7263TCCDL7280SCCDL7280YCCDL7280TCCDL72100SCCDL72100YCCDL72100TC
CDL7410LCCDL7410SCCDL7410YCCDL7410TCCDL7416LCCDL7416SCCDL7416YCCDL7416TCCDL7425LCCDL7425SCCDL7425YCCDL7425TCCDL7440SCCDL7440YCCDL7440TCCDL7463SCCDL7463YCCDL7463TCCDL7480SCCDL7480YCCDL7480TCCDL74100SCCDL74100YCCDL74100TC
CDL7410LACDL7410SACDL7410YACDL7410TACDL7416LACDL7416SACDL7416YACDL7416TACDL7425LACDL7425SACDL7425YACDL7425TACDL7440SACDL7440YACDL7440TACDL7463SACDL7463YACDL7463TACDL7480SACDL7480YACDL7480TACDL74100SACDL74100YACDL74100TA
CDL7210LACDL7210SACDL7210YACDL7210TACDL7216LACDL7216SACDL7216YACDL7216TACDL7225LACDL7225SACDL7225YACDL7225TACDL7240SACDL7240YACDL7240TACDL7263SACDL7263YACDL7263TACDL7280SACDL7280YACDL7280TACDL72100SACDL72100YACDL72100TA
10
16
25
40
63
80
100
10301003001030100300103010030030100300301003003010030030100300
10
16
25
40
63
80
100
32
Final Distribution
CDL7 Electromagnetic Type Residual Current SwitchStandard: IEC 61008RCCB Type: A , ACSensitivity: 10, 30, 100, 300mA
Technical Data
Overall Dimensions
RCCB CDL7 Electromagnetic Type Residual Current Switch
Connection
Installation
Mounting 35mm Din-rail
Standard
Certification
Type
IEC61008
KEMA、CB
AC, A
2P、4P
230/400V AC
500V
10,30,100,300mA
no
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Sensitivity
1000 times
2000 times
Tripping Indication
Fault Curren Indicator Mechanical indication in the front
Protection Degree 2
Tropicalization
Up to 16mm2 cables(In>63A)Up to 35mm2
Treatment 2
Ambient Temperature -25℃~+40℃
ScrewRatecurrent(A)
Rated Torque(Nm)
Limiting Torque(Nm)
25-100 M5 2.0 4.5
Not need
Overload or Short Circuit Protection
Instantaneous, rated residualoperated current unadjustable
10,16,25,40,63,80,100P
Mechanical Features
Electrical Features
Power source Auxilary
A
y
Mechanical Durability
Electrical Durabilit
,
,
33
Final Distribution
The sketch map of installation with breakers
Remote Control Auxiliaries
SD OF Breaker MX+OF
OF contact auxiliaryIndicate ON or OFF state of the breakerBasic type of auxiliary contact:1NO+1NCConnection: 1-4mm2 cables
SD fault-indicating switch Sent out fault signal on the font when breaking down Indicator on the front to show fault trip Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables
MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip once got signal Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables
Tripping DeviceOF, SD must be assembled on the left ,one auxiliary only Each time only one auxiliary accepted in the left of MCB MX+OF must be assembled on the right, one MX+OF only CDB6LE can't assemble MX+OF
Introductions
SD OF MX+OF
AccessoryCDB6,CDB6LE
Order Information
type Width(mm) Voltage(V) Reference
OF 9 CDB6OF
SD 9 CDB6SD
MX+OF 18
18
18
18
18
18
18
CDB6MX110
CDB6MX130
CDB6MX230
CDB6MX400
CDB6MX12
CDB6MX24
CDB6MX48
AC 110-130V
AC 130V
AC 230V
AC 400V
AC/DC 12V
AC/DC 24V
AC/DC 48V
34
Final Distribution
type Width(mm) Voltage(V) Reference
OF 9 CDB6sOF
SD 9 CDB6sSD
The sketch map of installation with breakers
OF contact auxiliaryIndicate ON or OFF state of the breakerBasic type of auxiliary contact:1NO+1NCConnection:1-4mm2 cables
SD fault-indicating switch Sent out fault signal when breaking down Indicator on the front to show fault trip Basic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables
MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip while given signalBasic type of auxiliary contact:1NO+1NC Connection:1-4mm2 cables
OF,SD must be assembled on the left ,one auxiliary only Each time only one auxiliary accepted in the left of MCB MX+OF must be assembled on the right, one MX+OF only CDB6s can't assemble MX+OF while assembled with CDB6v
SD OF MX+OFCDB6s
AccessoryCDB6s
Order Information
IntroductionsTripping Device
Remote Control Auxiliaries
MX+OF 1 CDB6sMX24
CDB6sMX48
CDB6sMX110
CDB6sMX230
18
18
18
18 AC230-400V
AC/DC12-24V
AC/DC24-48V
AC110-127V
35
Final Distribution
Type Width(mm) Description Reference
OF 18 1NO 1NC CDB2OF11
18 2NO 2NC CDB2OF22
MX+OF 18 CDB2MX24
18 AC48V~130V DC48V CDB2MX48
18 AC230V-400V DC110V-130V CDB2MX230
The sketch map of installation with breakers
MX+OF OF Breaker
OF contact auxiliaryIndicate ON or OFF state of the breakerBasic type of auxiliary contact:2NO+2NCConnection: 1-4mm2 cables
MX+OF shunt trip release Indicate ON or OFF state of the breaker Make the assembled breaker trip once got signal Basic type of auxiliary contact:1NO+1NC Connection: 1-4mm2 cables
MX+OF, OF must be assembled on the left Each time only one auxiliary accepted in the left of MCB
AccessoryCDB2,CDB2LE
Order Information
Tripping Device
Remote Control Auxiliaries Introductions
AC/DC24V
36
Final Distribution
Technical Data
AccessoryBusbar
A
A
A
A
A
A
A
A
Order Information
PIN-TYPE
U-TYPE
1
2
3
4
1
2
3
4
1.21.51.51.51.21.51.51.51.21.51.51.51.21.51.51.51.21.51.51.51.21.51.51.51.21.51.51.51.21.51.51.5
61013166101316610131661013166101316610131661013166101316
4063708040637080406370804063708040637080406370804063708040637080
Type PoleThickness of pin (mm)
Section cross (mm2)
Max. current(A) End feed-in
A Reference Dimension(mm)
CBB14012PCBB16315PCBB17015PCBB18015PCBB24012PCBB26315PCBB27015PCBB28015PCBB34012PCBB36315PCBB37015PCBB38015PCBB44012PCBB46315PCBB47015PCBB48015PCBB14012FCBB16315FCBB17015FCBB18015FCBB24012FCBB26315FCBB27015FCBB28015FCBB34012FCBB36315FCBB37015FCBB38015FCBB44012FCBB46315FCBB47015FCBB48015F
StandardMaterial of busbarMaterial of insulationShort-circuit strengthNominal voltageOperating voltageSurge voltageClima stability
IEC 60664E-CU-F25PVC50kA415VMax 500V4kVIEC 60068-2
5791157911579115791157911579115791157911
37
Final Distribution
CDCH8 Modular ContactorStandard: IEC 61095
Function
Pole Reference
CDCH8202MCDCH8202NCDCH8252MCDCH8252N
2P 20
25
Current (A)
220V230V220V230V
Voltage (V)
Order Information
Technical Data
Standard
Certification
Type
Rated Voltage Ue
Rated Insulation Voltage Ui
Conventional Thermal Current(I )
Rated Current(le)
Rated power
Operation Frequency
Operation Time
Making&Breaking capacity
With stand Overcurrent Capacity
Short-circuit Protection
Ambient Temperature
Connection
Coil Voltage(Us)
Allowable Voltage ofControlloop(V)
Rated Power of Coil
Operating:85%~110%UsRelease:20%~75%Us
Start:16VAHolding:4VAWorking power:1.4W
Techenical Data of Coil
Building Control Command Devices CDCH8 Modular Contactor
IEC 61095
KEMA CE CB
AC-7bAC-7a
230V AC
500V AC
20A/25A
9A/10A20A/25A
1.2kw/1.4kw4kw/5.4kw
≥30000times
30times/h1200times/h
8le1.5le
AC-7b,8le,10S
Adapted to fuse :RT18-32X/32
Adapted to breaker :CDB6s-63/C32
-5℃~+40℃
Both 1 and 2 lines can be usedCDCH8-20 1~2.5mm , CDCH8-25,1~4mm2 2
~
220/230V AC
CDCH8 Modular Contactor provide:Automatic control on equipment in buildingsSwitch on or Swith off lighting or other equipments
38
Final Distribution
CDCH8 Modular ContactorStandard: IEC 61095
Overall Dimensions
Wiring Diagram
39
Final Distribution
Function
CDRT8 Time RelayStandard:IEC 60947.5
Order Information
Technical Data
CDRT8 Time Relay provide:Disconnect DelayConnect Delay
Limit delay time Delay type Reference
CDRT810B
CDRT8120B
CDRT8480A
power delay
power delay
off delay
10
120
480
480
power delay CDRT8480B
Standard
Rated Voltage Ue
Rated Current(le)
Delay Type
Timing Range
Contact TypeContact NumberRated Control Supply Voltage(Us)Operating Voltage Range
Rated WattageInsulation ResistanceInsulation Strength
Connection
Limit Delay TimeConventional Thermal Current(l )
CDRT8 Time RelayBuilding Control Command Devices
up to 1mm cables2
To each:AC 1760V 5s
Disconnect between the
contact position:AC 1000V 1min
<1W>
85%-110%Us230V AC1Normally open contact
8A10s 120s 480s
Off dalay
Power delay
5A
230V AC
th
Electrical Durability 30000 times
IEC 60947.5
40
Final Distribution
CDRT8 Time RelayStandard:IEC 60947.5
Wiring Diagram
19max
68max
Overall Dimensions
41
Final Distribution
Function
CDY1 Surge Protective Devices Standard: IEC61643
CDY1 surge protective devices provide: Applicable to household appliances and the like to offer protection When there is an over-voltage caused by either lightning strike or operation in the circuit
Order InformationImax(kA)
Uc (V)
Up (kV)
Reference
1P 2P 3P 4P 1P+N 3P+N
20 275 1.3 CDY1201275 CDY1202275 CDY1203275 CDY1204275 CDY1205275 CDY1206275
385 1.5 CDY1201385 CDY1202385 CDY1203385 CDY1204385 CDY1205385 CDY1206385
420 1.8 CDY1201420 CDY1202420 CDY1203420 CDY1204420 CDY1205420 CDY1206420
40 275 1.5 CDY1401275 CDY1402275 CDY1403275 CDY1404275 CDY1405275 CDY1406275
385 1.8 CDY1401385 CDY1402385 CDY1403385 CDY1404385 CDY1405385 CDY1406385
420 2.0 CDY1401420 CDY1402420 CDY1403420 CDY1404420 CDY1405420 CDY1406420
60 275 1.8 CDY1601275 CDY1602275 CDY1603275 CDY1604275 CDY1605275 CDY1606275
385 2.2 CDY1601385 CDY1602385 CDY1603385 CDY1604385 CDY1605385 CDY1606385
420 2.5 CDY1601420 CDY1602420 CDY1603420 CDY1604420 CDY1605420 CDY1606420
80 275 2.0 CDY1801275 CDY1802275 CDY1803275 CDY1804275 CDY1805275 CDY1806275
385 2.2 CDY1801385 CDY1802385 CDY1803385 CDY1804385 CDY1805385 CDY1806385
420 2.5 CDY1801420 CDY1802420 CDY1803420 CDY1804420 CDY1805420 CDY1806420
100 275 2.2 CDY11001275 CDY11002275 CDY11003275 CDY11004275 CDY11005275 CDY11006275
385 2.5 CDY11001385 CDY11002385 CDY11003385 CDY11004385 CDY11005385 CDY11006385
420 2.5 CDY11001420 CDY11002420 CDY11003420 CDY11004420 CDY11005420 CDY11006420
ReferenceImax (kA)
Uc (V)
Up (kV) 1P 2P 3P 4P 1P+N
Imax(kA)
Uc (V)
Up (kV)
Reference
1P 2P 3P 4P 1P+N 3P+N
20 275 1.3 CDY1201275 CDY1202275 CDY1203275 CDY1204275 CDY1205275 CDY1206275
385 1.5 CDY1201385 CDY1202385 CDY1203385 CDY1204385 CDY1205385 CDY1206385
420 1.8 CDY1201420 CDY1202420 CDY1203420 CDY1204420 CDY1205420 CDY1206420
40 275 1.5 CDY1401275 CDY1402275 CDY1403275 CDY1404275 CDY1405275 CDY1406275
385 1.8 CDY1401385 CDY1402385 CDY1403385 CDY1404385 CDY1405385 CDY1406385
420 2.0 CDY1401420 CDY1402420 CDY1403420 CDY1404420 CDY1405420 CDY1406420
60 275 1.8 CDY1601275 CDY1602275 CDY1603275 CDY1604275 CDY1605275 CDY1606275
385 2.2 CDY1601385 CDY1602385 CDY1603385 CDY1604385 CDY1605385 CDY1606385
420 2.5 CDY1601420 CDY1602420 CDY1603420 CDY1604420 CDY1605420 CDY1606420
80 275 2.0 CDY1801275 CDY1802275 CDY1803275 CDY1804275 CDY1805275 CDY1806275
385 2.2 CDY1801385 CDY1802385 CDY1803385 CDY1804385 CDY1805385 CDY1806385
420 2.5 CDY1801420 CDY1802420 CDY1803420 CDY1804420 CDY1805420 CDY1806420
100 275 2.2 CDY11001275 CDY11002275 CDY11003275 CDY11004275 CDY11005275 CDY11006275
385 2.5 CDY11001385 CDY11002385 CDY11003385 CDY11004385 CDY11005385 CDY11006385
420 2.5 CDY11001420 CDY11002420 CDY11003420 CDY11004420 CDY11005420 CDY11006420
ReferenceImax (kA)
Uc (V)
Up (kV) 1P 2P 3P 4P 1P+N 3P+N
Reference
42
Final Distribution
CDY1 Surge Protective Devices Standard: IEC61643
Technical Data
Overall Dimensions
CDY1-80 CDY1-100CDY1-60CDY1-40CDY1-201P, 1P+N, 2P, 3P, 3P+N, 4P10
20
275
1.3
385
1.5
420
1.8
20
40
30
60
40
80
50
100
275
1.5
420
2.0
275
1.8
420
2.5
385
2.2
275
2.0
420
2.5
385
2.2
275
2.2
420
2.5
385
2.5
TypePole Nominal discharge current In(8/20us) kAMaximum discharge current Imax(8/20us) kA Maximum continuous operational voltage Uc V Protection level Up kV Leakage current (75%Uc 1mA) uA Response time ns
≤20
≤25
385
1.8
Standard: IEC 61643
Certification: SEMKO, CB
43
Final Distribution
Function
Order Information
CDPZ50 Series Lighting Distribution BoxStandard: IEC60439-1 IEC60670
Material No. of loop ReferenceFull plastic Surface installation 4 CDPZ50PM4IP30F(fire-retardancy) 6 CDPZ50PM6IP30F
8 CDPZ50PM8IP30F12 CDPZ50PM12IP30F15 CDPZ50PM15IP30F18 CDPZ50PM18IP30F24 CDPZ50PM24IP30F36 CDPZ50PM36IP30F
Flush installation 4 CDPZ50PR4IP30F6 CDPZ50PR6IP30F8 CDPZ50PR8IP30F12 CDPZ50PR12IP30F15 CDPZ50PR15IP30F18 CDPZ50PR18IP30F24 CDPZ50PR24IP30F36 CDPZ50PR36IP30F
Full plastic Surface installation 4 CDPZ50PM4IP30NF(Non fire-retardancy) 6 CDPZ50PM6IP30NF
8 CDPZ50PM8IP30NF12 CDPZ50PM12IP30NF15 CDPZ50PM15IP30NF18 CDPZ50PM18IP30NF24 CDPZ50PM24IP30NF36 CDPZ50PM36IP30NF
Flush installation 4 CDPZ50PR4IP30NF6 CDPZ50PR6IP30NF8 CDPZ50PR8IP30NF12 CDPZ50PR12IP30NF15 CDPZ50PR15IP30NF18 CDPZ50PR18IP30NF24 CDPZ50PR24IP30NF36 CDPZ50PR36IP30NF
Installation
Material ReferenceHolistic steel-plastic Surface installation 6 CDPZ50M6
8 CDPZ50M812 CDPZ50M1216 CDPZ50M1620 CDPZ50M2024 CDPZ50M24
Flush installation 6 CDPZ50R68 CDPZ50R812 CDPZ50R1216 CDPZ50R1620 CDPZ50R2024 CDPZ50R24
Installation No. of loop
CDPZ50 series lighting distribution box provide: Protection against overload Protection against over voltage Protection against leakage
44
Final Distribution
Surface installation Flush installation
CDPZ50 Series Lighting Distribution BoxStandard: IEC60439-1 IEC60670
Technical Data
Unit:mmOverall Dimensions
CDPZ50
Surface installationA
ThicknessC909090909090
B200200200200200364
Flush installationA163199272343413282
B220220220220220383
171207279351423303
6812162024
Holistic steel-plasticLoop number
CDPZ50P
Surface installationA B
Flush installationA B
Full plasticLoop number4681215182436
110147183255310362270270
200200200200200218324459
126162198270324378261261
200200200200200216310441
ThicknessC9090909090909090
Full Plastic
Optional
Material
Fire-resistancy Fire-resistancy
Protection grade
Rated operation voltage
Rated insulated voltage
Rated operating current
Withstand current
IP30
230/400V
500V
100A
6kA
Box:Metal, Cover:Plastic
CDPZ50 CDPZ50PType
45
Final Distribution
Order Information
Thick
Overall Installation Mounting plate
(mm)
Lock
JXF-2520/14 IP43 Improved 1.0 250 200 140 290 150 170 158 1.0 1 JXF252014BJXF-3025/14 IP43 Improved 1.0 300 250 140 340 200 220 208 1.0 1 JXF302514BJXF-3025/18 IP43 Improved 1.0 300 250 180 340 200 220 208 1.0 1 JXF302518BJXF-3030/14 IP43 Improved 1.0 300 300 140 340 250 220 258 1.0 1 JXF303014BJXF-3030/18 IP43 Improved 1.0 300 300 180 340 250 220 258 1.0 1 JXF303018BJXF-4030/14 IP43 Improved 1.0 400 300 140 440 250 320 258 1.0 1 JXF403014BJXF-4030/20 IP43 Improved 1.0 400 300 200 440 250 320 258 1.0 1 JXF403020BJXF-5040/14 IP43 Improved 1.0 500 400 140 540 350 420 358 1.0 2 JXF504014BJXF-5040/20 IP43 Improved 1.0 500 400 200 540 350 420 358 1.0 2 JXF504020BJXF-5040/25 IP43 Improved 1.0 500 400 250 540 350 420 358 1.0 2 JXF504025BJXF-6040/14 IP43 Improved 1.2 600 400 140 640 350 520 358 1.2 2 JXF604014BJXF-6040/20 IP43 Improved 1.2 600 400 200 640 350 520 358 1.2 2 JXF604020BJXF-6040/25 IP43 Improved 1.2 600 400 250 640 350 520 358 1.2 2 JXF604025BJXF-6050/14 IP43 Improved 1.2 600 500 140 640 450 520 458 1.2 2 JXF605014BJXF-6050/20 IP43 Improved 1.2 600 500 200 640 450 520 458 1.2 2 JXF605020BJXF-6050/25 IP43 Improved 1.2 600 500 250 640 450 520 458 1.2 2 JXF605025BJXF-7050/16 IP43 Improved 1.2 700 500 160 740 450 620 458 1.2 2 JXF705016BJXF-7050/20 IP43 Improved 1.2 700 500 200 740 450 620 458 1.2 2 JXF705020BJXF-7050/25 IP43 Improved 1.2 700 500 250 740 450 620 458 1.2 2 JXF705025BJXF-8060/20 IP43 Improved 1.5 800 600 200 840 550 720 558 1.5 2 JXF806020BJXF-8060/25 IP43 Improved 1.5 800 600 250 840 550 720 558 1.5 2 JXF806025BJXF-10080/20 IP43 Improved 1.5 1000 800 200 1040 750 920 758 1.5 2 JXF1008020BJXF-10080/25 IP43 Improved 1.5 1000 800 250 1040 750 920 758 1.5 2 JXF1008025BJXF-10080/30 IP43 Improved 1.5 1000 800 300 1040 750 920 758 1.5 2 JXF1008030B
JXF-2520/14 IP43 1.0 250 200 140 290 150 170 158 1.0 1 JXF252014JXF-3025/14 IP43 1.0 300 250 140 340 200 220 208 1.0 1 JXF302514JXF-3025/18 IP43 1.0 300 250 180 340 200 220 208 1.0 1 JXF302518JXF-3030/14 IP43 1.0 300 300 140 340 250 220 258 1.0 1 JXF303014JXF-3030/18 IP43 1.0 300 300 180 340 250 220 258 1.0 1 JXF303018JXF-4030/14 IP43 1.0 400 300 140 440 250 320 258 1.0 1 JXF403014JXF-4030/20 IP43 1.0 400 300 200 440 250 320 258 1.0 1 JXF403020JXF-5040/14 IP43 1.0 500 400 140 540 350 420 358 1.0 1 JXF504014JXF-5040/20 IP43 1.0 500 400 200 540 350 420 358 1.0 2 JXF504020JXF-5040/25 IP43 1.0 500 400 250 540 350 420 358 1.0 2 JXF504025JXF-6040/14 IP43 1.2 600 400 140 640 350 520 358 1.2 2 JXF604014JXF-6040/20 IP43 1.2 600 400 200 640 350 520 358 1.2 2 JXF604020JXF-6040/25 IP43 1.2 600 400 250 640 350 520 358 1.2 2 JXF604025JXF-6050/14 IP43 1.2 600 500 140 640 450 520 458 1.2 2 JXF605014JXF-6050/20 IP43 1.2 600 500 200 640 450 520 458 1.2 2 JXF605020JXF-6050/25 IP43 1.2 600 500 250 640 450 520 458 1.2 2 JXF605025JXF-7050/16 IP43 1.2 700 500 160 740 450 620 458 1.2 2 JXF705016JXF-7050/20 IP43 1.2 700 500 200 740 450 620 458 1.2 2 JXF705020JXF-7050/25 IP43 1.2 700 500 250 740 450 620 458 1.2 2 JXF705025JXF-8060/20 IP43 1.5 800 600 200 840 550 720 558 1.5 2 JXF806020JXF-8060/25 IP43 1.5 800 600 250 840 550 720 558 1.5 2 JXF806025JXF-10080/20 IP43 1.5 1000 800 200 1040 750 920 758 1.5 2 JXF1008020JXF-10080/25 IP43 1.5 1000 800 250 1040 750 920 758 1.5 2 JXF1008025JXF-10080/30 IP43 1.5 1000 800 300 1040 750 920 758 1.5 2 JXF1008030
Function JXF power distribution box provide: Control, monitering, measurement and protection for the electric power loops and main power controlling equipment.
JXF Power Distribution BoxStandard: EN60529
46
Final Distribution
(mm)
Thick
Overall Installation
Dimension(mm)
Mounting plate Lock
JXF-2520/14 IP54 1.2 250 200 140 320 150 215 148 2.0 1 JXF252014QJXF-3025/14 IP54 1.2 300 250 140 370 200 265 198 2.0 1 JXF302514QJXF-3025/18 IP54 1.2 300 250 180 370 200 265 198 2.0 1 JXF302518QJXF-3030/14 IP54 1.2 300 300 140 370 250 265 248 2.0 1 JXF303014QJXF-3030/18 IP54 1.2 300 300 180 370 250 265 248 2.0 1 JXF303018QJXF-4030/14 IP54 1.2 400 300 140 470 250 365 248 2.0 1 JXF403014QJXF-4030/20 IP54 1.2 400 300 200 470 250 365 248 2.0 1 JXF403020QJXF-5040/14 IP54 1.2 500 400 140 570 350 465 348 2.0 2 JXF504014QJXF-5040/20 IP54 1.2 500 400 200 570 350 465 348 2.0 2 JXF504020QJXF-5040/25 IP54 1.2 500 400 250 570 350 465 348 2.0 2 JXF504025QJXF-6040/14 IP54 1.5 600 400 140 670 350 565 348 2.0 2 JXF604014QJXF-6040/20 IP54 1.5 600 400 200 670 350 565 348 2.0 2 JXF604020QJXF-6040/25 IP54 1.5 600 400 250 670 350 565 348 2.0 2 JXF604025QJXF-6050/14 IP54 1.5 600 500 140 670 450 565 448 2.0 2 JXF605014QJXF-6050/20 IP54 1.5 600 500 200 670 450 565 448 2.0 2 JXF605020QJXF-6050/25 IP54 1.5 600 500 250 670 450 565 448 2.0 2 JXF605025QJXF-7050/16 IP54 1.5 700 500 160 770 450 665 448 2.0 2 JXF705016QJXF-7050/20 IP54 1.5 700 500 200 770 450 665 448 2.0 2 JXF705020QJXF-7050/25 IP54 1.5 700 500 250 770 450 665 448 2.0 2 JXF705025QJXF-8060/20 IP54 1.5 800 600 200 870 550 765 548 2.0 2 JXF806020QJXF-8060/25 IP54 1.5 800 600 250 870 550 765 548 2.0 2 JXF806025QJXF-10080/20 IP54 1.5 1000 800 200 1070 750 965 748 2.0 2 JXF1008020QJXF-10080/25 IP54 1.5 1000 800 250 1070 750 965 748 2.0 2 JXF1008025QJXF-10080/30 IP54 1.5 1000 800 300 1070 750 965 748 2.0 2 JXF1008030Q
Order Information
JXF Power Distribution BoxStandard: EN60529
47
Final Distribution
Technical Data
handle lock
hingedoor
box
Unit: mm
Overall Dimensions
JXF IP43 JXF IP54
Protection grade
Standard:
Certificate
Rated voltage
Rated insulated voltage
Rated operating current
Withstand current
Sheet thickness
Mounting plate thickness
Hinge
Sealing rubber gasket
Cable gland
JXF IP43 Improved
sealing rubber gasket
sealing rubber gasket
wall fixing bracket
Type
JXF Power Distribution BoxStandard: EN60529
JXF-2520/14 IP54 1.2 250 200 140 320 150 215 148 2.0 1 JXF252014QJXF-3025/14 IP54 1.2 300 250 140 370 200 265 198 2.0 1 JXF302514QJXF-3025/18 IP54 1.2 300 250 180 370 200 265 198 2.0 1 JXF302518QJXF-3030/14 IP54 1.2 300 300 140 370 250 265 248 2.0 1 JXF303014QJXF-3030/18 IP54 1.2 300 300 180 370 250 265 248 2.0 1 JXF303018QJXF-4030/14 IP54 1.2 400 300 140 470 250 365 248 2.0 1 JXF403014QJXF-4030/20 IP54 1.2 400 300 200 470 250 365 248 2.0 1 JXF403020QJXF-5040/14 IP54 1.2 500 400 140 570 350 465 348 2.0 2 JXF504014QJXF-5040/20 IP54 1.2 500 400 200 570 350 465 348 2.0 2 JXF504020QJXF-5040/25 IP54 1.2 500 400 250 570 350 465 348 2.0 2 JXF504025QJXF-6040/14 IP54 1.5 600 400 140 670 350 565 348 2.0 2 JXF604014QJXF-6040/20 IP54 1.5 600 400 200 670 350 565 348 2.0 2 JXF604020QJXF-6040/25 IP54 1.5 600 400 250 670 350 565 348 2.0 2 JXF604025QJXF-6050/14 IP54 1.5 600 500 140 670 450 565 448 2.0 2 JXF605014QJXF-6050/20 IP54 1.5 600 500 200 670 450 565 448 2.0 2 JXF605020QJXF-6050/25 IP54 1.5 600 500 250 670 450 565 448 2.0 2 JXF605025QJXF-7050/16 IP54 1.5 700 500 160 770 450 665 448 2.0 2 JXF705016QJXF-7050/20 IP54 1.5 700 500 200 770 450 665 448 2.0 2 JXF705020QJXF-7050/25 IP54 1.5 700 500 250 770 450 665 448 2.0 2 JXF705025QJXF-8060/20 IP54 1.5 800 600 200 870 550 765 548 2.0 2 JXF806020QJXF-8060/25 IP54 1.5 800 600 250 870 550 765 548 2.0 2 JXF806025QJXF-10080/20 IP54 1.5 1000 800 200 1070 750 965 748 2.0 2 JXF1008020QJXF-10080/25 IP54 1.5 1000 800 250 1070 750 965 748 2.0 2 JXF1008025QJXF-10080/30 IP54 1.5 1000 800 300 1070 750 965 748 2.0 2 JXF1008030Q
IP43
EN60529
CE
220/400V
660V
400A
15kA
1.0~1.5mm
1.0~1.5mm
Normal
Seal band
Top and bottom
IP43
1.0~1.5mm
1.0~1.5mm
Enhanced
Black rubber gasket
bottom only
IP54
1.2~1.5mm
2.0mm
Enhanced
Black rubber gasket
bottom only
48
Low-voltage
Distribution
Contents
Low-voltage Distribution
Molded Case Circuit BreakerCDM1 Molded Case Circuit Breaker
CDMLE Earth-Leakage Circuit Breaker
Air Circuit BreakerCDW7 Air Circuit Breaker
49-6349
57
64-8264
49
Distribution
Low
-voltage
CDM1 Moulded Case Circuit BreakerStandard: IEC 60947-2
Function CDM1 moulded case circuit breaker provide:To distribute electric powerTo protect power line and equipments against overload, undervoltage and short-circuit faults (In≤400A)To infrequently start and control AC motors
Type
CDM1-63 3P
4P
CDM1-100 2P
3P
4P
In A
10162025324050631016202532405063162025324050638010016202532405063801001620253240506380100
ReferenceType MCDM163M103CDM163M163CDM163M203CDM163M253CDM163M323CDM163M403CDM163M503CDM163M633CDM163M104CDM163M164CDM163M204CDM163M254CDM163M324CDM163M404CDM163M504CDM163M634CDM1100M162 CDM1100M202 CDM1100M252 CDM1100M322 CDM1100M402 CDM1100M502 CDM1100M632 CDM1100M802 CDM1100M1002 CDM1100M163 CDM1100M203 CDM1100M253 CDM1100M323 CDM1100M403 CDM1100M503 CDM1100M633CDM1100M803CDM1100M1003CDM1100M164CDM1100M204CDM1100M254CDM1100M324CDM1100M404CDM1100M504CDM1100M634CDM1100M804CDM1100M1004
Order Information
Type LCDM163L103CDM163L163CDM163L203CDM163L253CDM163L323CDM163L403CDM163L503CDM163L633----------------------------------CDM1100L163 CDM1100L203 CDM1100L253 CDM1100L323 CDM1100L403 CDM1100L503CDM1100L633CDM1100L803 CDM1100L1003------------------
50
Low-voltage
Distribution
Note: The connection mode for CDM1 is the fixed type front connection.
CDM1 Moulded Case Circuit BreakerStandard: IEC 60947-2
Order Information
Type In A
100125160180200225
CDM1-225 2P
10012516018020022510012516018020022520022525031535040020021525031535040040050063040050063040050063070080040050063070080070080010001250
ReferenceType MCDM1225M1002 CDM1225M1252 CDM1225M1602 CDM1225M1802 CDM1225M2002CDM1225M2252CDM1225M1003CDM1225M1253CDM1225M1603CDM1225M1803CDM1225M2003CDM1225M2253CDM1225M1004CDM1225M1254CDM1225M1604CDM1225M1804CDM1225M2004CDM1225M2254CDM1400M2003CDM1400M2253CDM1400M2503CDM1400M3153CDM1400M3503CDM1400M4003CDM1400M2004 CDM1400M2254 CDM1400M2504 CDM1400M3154CDM1400M3504CDM1400M4004 CDM1630M4003CDM1630M5003CDM1630M6303CDM1630M4004CDM1630M5004CDM1630M6304CDM1800M4003CDM1800M5003CDM1800M6303CDM1800M7003CDM1800M8003CDM1800M4004 CDM1800M5004 CDM1800M6304 CDM1800M7004 CDM1800M8004 CDM11250M7003 CDM11250M8003CDM11250M10003CDM11250M12503
Type L------------CDM1225L1003CDM1225L1253CDM1225L1603CDM1225L1803CDM1225L2003CDM1225L2253------------CDM1400L2003CDM1400L2253CDM1400L2503CDM1400L3153CDM1400L3503CDM1400L4003------------CDM1630L4003CDM1630L5003CDM1630L6303------CDM1800L4003 CDM1800L5003 CDM1800L6303 CDM1800L7003 CDM1800L8003 ------------------
3P
4P
CDM1-400 3P
4P
CDM1-630 3P
4P
CDM1-800 3P
4P
CDM1-1250 3P
51
Distribution
Low
-voltage
CDM1-63
CDM1-100
CDM1-225
CDM1-400
CDM1-630
CDM1-800
CDM1-1250
230V AC400V AC
ReferenceMNCDM163MN230*CDM163MN400*CDM1100MN230*CDM1100MN400*CDM1225MN230*CDM1225MN400*CDM1400MN230*CDM1400MN400*CDM1630MN230*CDM1630MN400*CDM1800MN230*CDM1800MN400*CDM11250MN230*CDM11250MN400*
MXCDM163MX230*CDM163MX400*CDM1100MX230*CDM1100MX400*CDM1225MX230*CDM1225MX400*CDM1400MX230*CDM1400MX400*CDM1630MX230*CDM1630MX400*CDM1800MX230*CDM1800MX400*CDM11250MX230*CDM11250MX400*
OFCDM163OF*
CDM1100OF*
CDM1225OF*
CDM1400OF*
CDM1630OF*
CDM1800OF*
CDM11250OF*
SDCDM163SD*
CDM1100SD*
CDM1225SD*
CDM1400SD*
CDM1630SD*
CDM1800SD*
TR(Round Handle)CDM163TR
CDM1100TR
CDM1225TR
CDM1400TR
CDM1630TR
CDM1800TR
TS(Square Handle)CDM163TS
CDM1100TS
CDM1225TS
CDM1400TS
CDM1630TS
CDM1800TS
Order Information for Assessories
CDM1 Moulded Case Circuit BreakerStandard: IEC 60947-2
61 11
72 12
83 13
94
15 0
Connection
Phase partition
Motor mechanism
Round handle mechanism
Quadrate handle mechanism
Shunt release contactor R
Alarm contactor
Auxiliary contactor
Undervoltage release contactor
Note 1: MN and MX could be sold with CDM1 product and installed by manufactory 2: *means the connecting type; Blank: terminal connection; D5: 500mm wire connection
1 2
3
11
10
9
4
5
6
7
8
12
13
Voltage (V) Type
Plug-type front connectionPlug-type rear connection
Stationary type rear connection
Plug-type connection terminal
52
Low-voltage
Distribution
CDM1 Moulded Case Circuit BreakerStandard: IEC 60947-2
Technical Data
Main technical parameters are shown in the table below
Type MType LType MType L
Cycles/hElectricalMechanical FixedPlug-in
Constructional featuresThermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrentThe circuit breaker can be fixed type or plug-in typeFor 4-pole circuit breakers:N-pole without overcurrent release, it switches on and off with other poles ( N-pole lead-make, lag-break)Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part
standard IEC 60947-2
MCCB KEMA,SEMKO,CB,CE
MCCB CDM1
TypeFrame size rated current ANumber of polesRated frequency HzRated current In A
Rated insulation voltage Ui VRated impulse withstand voltage Uimp VRated operationalvoltage Ue VIcu kA(400V)Ics kA(400V)Arcing distance mmDurability
Power consumpution (W)
CDM1-6363
3P,4P50/6010 16 20 25 32 40 50 63
690
6000
400
502530185012040006000 2530
CDM1-100100
2P,3P,4P
16 2025 3032 4050 6380 100800
8000
400 / 690
50353026
12015008500 4050
CDM1-400400
200 350250 315400
690/750
6000/8000
400
705040301006010004000 40110
CDM1-800800
400 500630 700800
690
6000
400
70504030
205002500 135190
CDM1-12501250
3P
700 8001000 1250
85-45-
205002500 240300
CDM1-225225
100 125160 180200 225
50353026
12010007000 6075
CDM1-630630
3P,4P
400 500630
40069065454234
6010004000 150200
53
Distribution
Low
-voltage
The accessories are fixed into the circuit breaker.■ Remote tripping:
MX or MN releases are used to trip the circuit breaker.■ This release trips the circuit breaker when the control voltage drops below the trip-
ping threshold: □ Tripping threshold between 35% to 70% of the rated voltage□ Circuit-breaker closing is possible only if the voltage exceeds 85% of the rated
voltage.■ Circuit-breaker tripping by an MN release meets the requirements of standard
IEC 60947-2.
MN (Undervoltage Release)
Accessories
Technical dataRated operating voltage Ue(V)Drop-out voltage(V)Pick-up voltage(V)
230V, 400V AC(0.35~0.7) Ue(0.85~1.1) Ue
MX (Shunt Release)
Technical dataRated control voltage US(V)Operating voltage(V)
230V, 400V AC(0.7~1.1) US
■ MX shunt release:□ The MX release trips the circuit breaker when the control voltage rises above 0.7 x Un.□ Control signals can be of the impulse type (u 20 ms) or maintained.
■ Indication contacts:□ These common-point changeover contacts can be used to remotely indicate circuit-breaker status information for indications, electrical locking, relays, etc.□ They comply with international standard IEC 60947-5.■ Functions:□ OF (ON/OFF): indicates the position of the circuit-breaker contacts.□ SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload v short-circuit v operation of a voltage release v operation of the“push-to-trip” button Returns to de-energised state when the circuit breaker is reset.
OF (Auxiliary Contactor)
Rated thermal current Ith 3ARated operating current 1NO+1NC (Change over)2NO+2NC (Change over)
SD (Alarm Contactor)
Rated thermal current Ith 3ARated operating current
1NO+1NC
Technical data
0.4A (400V AC)
Technical data
0.26A (400V AC)0.4A (400V AC)
power source input
“Trip” position
Arm Switch wiring diagram
Auxiliary Contact wiring diagram
power source input
Standard: IEC 60947-2
CDM1 Moulded Case Circuit Breaker
54
Low-voltage
Distribution
CDM1 Moulded Case Circuit BreakerStandard: IEC 60947-2
Type
CDM1-63LCDM1-63MCDM1-63MCDM1-100MCDM1-100LCDM1-100MCDM1-100MCDM1-225MCDM1-225LCDM1-225MCDM1-225MCDM1-400L,MCDM1-400MCDM1-630L,MCDM1-630MCDM1-800L,MCDM1-800MCDM1-1250M
Poles
334233423343434343
b117117117129129129129126126126126215215200200243243375
Overall DimensionsL 135135135150150150150165165165165257257270270280280406
L1 2121215151515164646464105105118118102102104
W767610365929212275107107142140184182240210280210
H89999910387103103124108124124146146160160146146190
H2212828242524242424242436364141343458
H17482828768878710487104104100100108108103103140.5
Overall Dimensions
■ Overall and cut-out diagram of round handle
Unit:mm
2P 3P 4P
e
2P 3P 4P
hinge
Φd3.53.53.54.54.54.54.55.55.55.55.56.56.5777710
Install dimensionsa252525--303030--35353544445858707070
55
Distribution
Low
-voltage
■ Overall and cut-out diagram of square handle
■ Centrally revolvable type
Dimension for handle mechanism(centrally revolvable type)
■ Eccentrically rotating
Unit:mm
Unit:mm
Dimension for handle mechanism(eccentrically revolvable type)
FrameCDM1-63CDM1-100CDM1-225CDM1-400CDM1-630CDM1-800
FrameCDM1-100CDM1-225CDM1-400CDM1-630CDM1-800
A117129126215200243
A3535656048
B253035445870
B11.531151515
H495454768376
H4648616166
hinge
Standard: IEC 60947-2
CDM1 Moulded Case Circuit Breaker
56
Low-voltage
Distribution
Characteristic Curve of Circuit Breaker
CDM1-63 Time / current characteristic curve CDM1-100 Time / current characteristic curve CDM1-225 Time / current characteristic curve
For power distribution
CDM1-400 Time / current characteristic curve CDM1-630 Time / current characteristic curve
CDM1 Moulded Case Circuit BreakerStandard: IEC 60947-2
Delay trip
Instantaneous tripDelay trip
For power distribution
max
min
Instantaneous current
Delay trip Instantaneous trip
Instantaneous trip
min
max
For power distribution
Instantaneous trip
Instantaneous trip
Delay trip
max
min
Delay trip
For power distribution
Instantaneous trip
Instantaneous trip
Delay trip
Delay trip
min
max
max
Instantaneous current
Delay trip Instantaneous trip
For power distribution
min
57
Distribution
Low
-voltage
Coding System
Country codeCD
Product nameM1LE
Breaking capacityM
L: L type M: M type
Current16
16: 16A … 400: 400A
Pole3
3:3 pole4:4 pole
Frame current100
100:100A225:225A400:400A
Usage
Blank fordistributionprotection
Residual currentL
S:30mAY:100mAT:300mAF:500mAKY:30/100/500mAKT:100/300/500mA
N PoleA
For CDM1LE4pole:A=A type (Direct connect)B=B type (Direct connect,lead-make, lag break)
Constructional featuresThermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrentThe residual operating current value can be fixed or adjustableThe residual operating current protection can be with time-delay or without time-delay Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the position indication contact, for detail see the accessories part
CDM1LE Earth-Leakage Circuit BreakerStandard: IEC 60947-2
Function
58
Low-voltage
Distribution
Order Information
CDM1LE Earth-Leakage Circuit BreakerStandard: IEC 60947-2
Note:* express residual current.
ReferenceType MCDM1LE100M163*CDM1LE100M203*CDM1LE100M253*CDM1LE100M323*CDM1LE100M403*CDM1LE100M503*CDM1LE100M633*CDM1LE100M803*CDM1LE100M1003*CDM1LE100M164*ACDM1LE100M204*ACDM1LE100M254*ACDM1LE100M324*ACDM1LE100M404*ACDM1LE100M504*ACDM1LE100M634*ACDM1LE100M804*ACDM1LE100M1004*ACDM1LE100M164*BCDM1LE100M204*BCDM1LE100M254*BCDM1LE100M324*BCDM1LE100M404*BCDM1LE100M504*BCDM1LE100M634*BCDM1LE100M804*BCDM1LE100M1004*BCDM1LE225M1003*CDM1LE225M1253*CDM1LE225M1403*CDM1LE225M1603*CDM1LE225M1803*CDM1LE225M2003*CDM1LE225M2253*CDM1LE225M1004*ACDM1LE225M1254*ACDM1LE225M1404*ACDM1LE225M1604*ACDM1LE225M1804*ACDM1LE225M2004*ACDM1LE225M2254*ACDM1LE225M1004*BCDM1LE225M1254*BCDM1LE225M1404*BCDM1LE225M1604*BCDM1LE225M1804*BCDM1LE225M2004*BCDM1LE225M2254*B
CDM1LE-100 3P
4P A
4P B
CDM1LE-225 3P
4P A
4P B
Rated current In A162025324050638010016202532405063801001620253240506380100100125140160180200225100125140160180200225100125140160180200225
Type LCDM1LE100L163*CDM1LE100L203*CDM1LE100L253*CDM1LE100L323*CDM1LE100L403*CDM1LE100L503*CDM1LE100L633*CDM1LE100L803*CDM1LE100L1003*CDM1LE100L164*ACDM1LE100L204*ACDM1LE100L254*ACDM1LE100L324*ACDM1LE100L404*ACDM1LE100L504*ACDM1LE100L634*ACDM1LE100L804*ACDM1LE100L1004*ACDM1LE100L164*BCDM1LE100L204*BCDM1LE100L254*BCDM1LE100L324*BCDM1LE100L404*BCDM1LE100L504*BCDM1LE100L634*BCDM1LE100L804*BCDM1LE100L1004*BCDM1LE225L1003*CDM1LE225L1253*CDM1LE225L1403*CDM1LE225L1603*CDM1LE225L1803*CDM1LE225L2003*CDM1LE225L2253*CDM1LE225L1004*ACDM1LE225L1254*ACDM1LE225L1404*ACDM1LE225L1604*ACDM1LE225L1804*ACDM1LE225L2004*ACDM1LE225L2254*ACDM1LE225L1004*BCDM1LE225L1254*BCDM1LE225L1404*BCDM1LE225L1604*BCDM1LE225L1804*BCDM1LE225L2004*BCDM1LE225L2254*B
Type
59
Distribution
Low
-voltage
Order Information
CDM1LE Earth-Leakage Circuit BreakerStandard: IEC 60947-2
Order Information for Accessories
CDM1LE400MN400 CDM1LE400MX400
CDM1LE225MN400 CDM1LE225MX400
CDM1LE100MN400 CDM1LE100MX400400V AC230V AC CDM1LE100MN230 CDM1LE100MX230 CDM1LE100OF CDM1LE100SD CDM1LE100TS CDM1LE100TRCDM1LE-100
CDM1LE225MN230 CDM1LE225MX230 CDM1LE225OF CDM1LE225SD CDM1LE225TS CDM1LE225TRCDM1LE-225
CDM1LE400MN230 CDM1LE400MX230 CDM1LE400OF CDM1LE400SD CDM1LE400TS CDM1LE400TRCDM1LE-400
Voltage(V)
Type ReferenceMN* MX* OF SD TS(Square Handle) TR(Round Handle)
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
CDM1LE400L2004*ACDM1LE400L2254*ACDM1LE400L2504*ACDM1LE400L3154*ACDM1LE400L3504*ACDM1LE400L4004*ACDM1LE400L2004*BCDM1LE400L2254*BCDM1LE400L2504*BCDM1LE400L3154*BCDM1LE400L3504*BCDM1LE400L4004*B
CDM1LE400L2003*CDM1LE400L2503*CDM1LE400L3153*CDM1LE400L3503*CDM1LE400L4003*
CDM1LE400M2004*ACDM1LE400M2254*ACDM1LE400M2504*ACDM1LE400M3154*ACDM1LE400M3504*ACDM1LE400M4004*ACDM1LE400M2004*BCDM1LE400M2254*BCDM1LE400M2504*BCDM1LE400M3154*BCDM1LE400M3504*BCDM1LE400M4004*B
CDM1LE400M2003*CDM1LE400M2503*CDM1LE400M3153*CDM1LE400M3503*CDM1LE400M4003*
4P A
4P B
CDM1LE-400 3PType L
ReferenceType
Note:* express residual current.
200250315350400
200225250315350400200225250315350400
Rated current In A Type M
Note 1: MN and MX could be sold with CDM1LE product and installed by manufactory 2: *means the connecting type; Blank: terminal connection; D5: 500mm wire connection
60
Low-voltage
Distribution
Technical Data
CodeAB
NoteN(direct connect)N(direct connect N pole lead-make, lag-break)
Table for 4 pole CDM1LE (Neutral line)
Maximum break time for residual operating current protectionNumber of polesMax. breaktime S
Without delayWith delay
TypeFrame size rated current ARated current In A
Rated frequency HzRated insulation voltage Ui VRated operational voltage Ue VRated impulse withstand voltage Uimp VNumber of polesIcu kA(400V)Ics kA(400V)Rated residualoperating current IΔn (mA)Rated residual non-operating current I Δn(mA)Durability
CDM1LE-10010016 20 25 32 40 50 63 80 10050/6080040080003P, 4P5035352230/100/500100/300/500100/300/5001/2 I Δn
1500850010000
Type MType LType MType LWithout delay
With delay
ElectricalMechanicalTotal
CDM1LE Earth-Leakage Circuit BreakerStandard: IEC 60947-2
The residual operating current value can be fxed or adjusted The residual operating current protection can be with time-delay or without time-delayVarious accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped positionindication contact, for detail see the accessories part
Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent
Constructional features
CDM1LE-400400200 250 315350 400
_50_30100/300/500
100/300/5001/2 I Δn
100040005000
CDM1LE-225225100 125 140 160180 200 225
5035352230/100/500100/300/500100/300/5001/2 I Δn
100070008000
I Δn0.20.5/1.15/2.15
2 I Δn0.10.35/1/2
5 I Δn0.040.25/0.9/1.9
10 I Δn0.040.25/0.9/1.9
fixed or adjusted
61
Distribution
Low
-voltage
Power source input
CDM1LE Earth-Leakage Circuit BreakerStandard: IEC 60947-2
■ Centrally revolvable type
FrameDimension
Dimension for handle mechanism
CDM1LE-10049
CDM1LE-22555
CDM1LE-40074
Unit:mm
Handle mechanism
■ Square Handle
AccessoriesThe accessories are fixed into the circuit breaker.■ Remote tripping:
MX or MN releases are used to trip the circuit breaker.■ This release trips the circuit breaker when the control voltage drops below the trip
ping threshold: □ tripping threshold between 0.35 and 0.7 times the rated voltage □ circuit-breaker closing is possible only if the voltage exceeds 0.85 times the rated
voltage.■ Circuit-breaker tripping by an MN release meets the requirements of standard
IEC 60947-2.
MN (Undervoltage Release)Technical dataRated operating voltage Ue(V)Drop-out voltage(V)Pick-up voltage(V)
230V, 400V AC(0.35~0.7) Ue(0.85~1.1) Ue
62
Low-voltage
Distribution
“Trip” position
Arm Switch wiring diagram
Auxiliary Contact wiring diagram
Power source input
MX (Shunt Release)
Technical dataRated control voltage Us(V)Operating voltage(V)
■ MX shunt release:□ The MX release trips the circuit breaker when the control voltage rises above 0.7 x Un.□ Control signals can be of the impulse type (u 20 ms) or maintained.
■ Indication contacts:□ These common-point changeover contacts can be used to remotely indicate circuit-breaker status information for indications, electrical locking, relays, etc.□ They comply with international standard IEC 60947-5.■ Functions:□ OF (ON/OFF): indicates the position of the circuit-breaker contacts.□ SD (trip indication): indicates that the circuit-breaker has tripped due to: v overload v short-circuit v operation of a voltage release v operation of the“push-to-trip” button Returns to de-energised state when the circuit breaker is reset.
OF (Auxiliary Contactor)
Rated thermal current Ith 3ARated operating current1NO+1NC (Change over)2NO+2NC (Change over)
Technical data
SD (Alarm Contactor)
Rated thermal current Ith 3ARated operating current
1NO+1NC
Technical data
230V, 400V AC(0.7~1.1) Us
0.4A (400V AC)
0.26A (400V AC)0.4A (400V AC)
CDM1LE Earth-Leakage Circuit BreakerStandard: IEC 60947-2
63
Distribution
Low
-voltage
Type
CDM1LE-100L
CDM1LE-100M
CDM1LE-225L
CDM1LE-225M
CDM1LE-400L,M
Poles
3434343434
150max150max150max150max165max165max165max165max257max257max
94max94max110max110max94max94max110max110max150max150max
75max75max92max92max72max72max90max90max107max107max
Key to Overall Dimensions
92max122max92max122max107max142max107max142max150max198max
CDM1LE Earth-Leakage Circuit BreakerStandard: IEC 60947-2
Overall Dimensions
Installation sizea b Φd
30603060357035704895
129129129129126126126126194194
4×Φ4.56×Φ4.54×Φ4.56×Φ4.54×Φ4.56×Φ4.54×Φ4.56×Φ4.54×Φ4.56×Φ6.5
Overall sizeL1 L2 L3 L4
Unit:mm
64
Low-voltage
Distribution
CDW7 Air Circuit BreakerStandard: IEC 60947-2
ApplicationApplied to power distribution of AC 50Hz/60Hz, rated operational voltage 400/690V, rated current 200A~6300A and lowerFor power distribution and protecting circuit and power supply equipment aganist harm from overload, undervoltage, short circuit, earthing, and other faultsCircuit breaker which ampere frame size is under 630A can protect motor aganist overload,undervoltage and shortcircuitCore parts use intelligent control unit which has accurate discrimination protection, it can avoid unnecessary power failure and enhance the reliability of power supply system
Standard and CertificationStandard: IEC60947-2Approved certification: CB, CE, KEMA
Operating condition and installation recommendation
Ambiant temperature
Altitude
Environmental humidity
Degree of pollutionInstallation position
Category of installation
Ambient temperature shall be controlled between+40℃ and -5℃, the average temperature in 24 hours shall not exceed +35℃Note:contacting manufacturer about circuit breaker used in place where ambient temperature is higher than +40℃ or lower than -5℃Altitude of installation position shall not exceed than 2000mThe relative humidity of the installation position shall not exceed 50% when the maximum temperature reached +40℃, but there can be higher relative humidity under lower temperature, for example, i t can reach 90% at 20℃. Cons ider ing tha t condensation occurred on product surface when temperature changesⅢ
Vertically mounting, tolerance on slope in any direction shall not exceed 5°Main circuit and undervoltage trip coil, power transformer primary coil:ⅥAuxiliary circuit,control circuit:Ⅲ
65
Distribution
Low
-voltage
Standard: IEC 60947-2
Parameter and characteristics
TypeNumber of polesUtilization categoriesArc-over distance (mm)Rated opertional voltage (V)Rated insulation voltage (V)Rated impulse withstand voltage (V)Rated frequency (Hz)Rated current (A)
Rated ultimate short circuit breaking capacity (kA)
Rated service short circuit breaking capacity (kA)
Rated short circuit making capacity (kA)
Rated short circuit withstand current (kA)
Service life(c/o cycles)
CDW7-10003, 4B0400690800050200/400/630/800/100042--30--88--30--90001000
CDW7-20003, 4B0400/690800800050630/800/1000/1250/1600/200065505040176105404090001000
CDW7-32003, 4B0400/6908008000502000/2500/32008065805022014350504500500
CDW7-63003, 4B04008008000504000/5000/6300120--100--264--85--1500500
UeUiUimp
In
Icu
Ics
Icm
Icw
mechanicalelectrical
AC 400VAC 690VAC 400VAC 690VAC 400VAC 690VAC 400VAC 690V
CDW7 Air Circuit Breaker
Certification approved: IEC 60947-1 IEC 60947-2
66
Low-voltage
Distribution
structural feature of ESW series intelligent controller
SEPECIFICATION 1-LCD interface display 2-Fault and alarm reset button 3-“Fault/Alarm” LED In normal state, this LED is off. In case of fault release, the red LED will flash quickly; in case of alarm, the red LED will be on constantly 4-“Normal” LED As long as the controller is on and operates normally, the green LED always flashes 5-Communication indicator The communication state indication is as follows: Profibus: OFF if no communication; ON if communication exists Modbus: OFF if no communication; flash if communication exists Device Net: Flash if no communication; ON if communication exists 6-Curve LEDs Red LEDs exist behind the curve. In case of fault release, the corresponding LED will flash indicating the fault type; During the parameter setting process, the LED is always on and indicates the current item.
Keypad 7-Measure key l, used to switch to the default measurement menu. 8-Set key 2, used to switch to the parameter setting menu. 9-Protection Key 3, used to switch to the protection parameter setting menu. 10-Info key 4, used to switch to the historical record and maintenance menu. 11-Up, Move up the cursor through the menu items on the current level, or increment the value of the selected parameter. 12-Down, Move down the cursor through the menu items on the current level, or decrement the value of the selected parameter. 13-Exit, exit from the current level and return to the upper level, or cancel the current parameter selection. 14-Select, Select to enter into the next level from the current item, or select the current parameter, or store the change.
Outline and operation of ECW series intelligent controller ECWS-H (Applicable to CDW7-1000)
Standard: IEC 60947-2
Protection characteristics
ECWS-H
RESET
Warn/ Alarm
Healthy
Bus
1
2
3
4
5
6
7 8 9 10
11 12 13 14
Isd
Ir1
Ir2
Ir4
Ir3
ELECTRIC
ECWS-H
CDW7 Air Circuit Breaker
Controller
Device
Floor plate
Interlocking deviceReset deviseMagnetic flux converterContactorBasic circuit
Chassis and other units
Mutual inductor
AC power supplyDC power supplyUPS
Chassis
Sensor
Relay
Power supplyaccessoriesAccessories
67
Distribution
Low
-voltage
SEPECIFICATION 1-Reset button of Fault release In case of breakers tripping, breakers cant be reclosed until this button is pressed.2-voltmeter display Display the phase current ,normally display the Max.phase current.3-light—emitting diode Indicators Display Setting , test , fault and Categorization 4-Ammeter display Display each of the phase current value and earth or leakage current value. Normally display Max. phase current value and can display the value of setting , test and fault current or time .5-Key button Setting , test, check various state and Categorization6-“lighting clear ”or “reset ”button When it is pressed ,the controller enters into normal run state , The breaker cant be closed until the button is pressed in case of setting, test, fault.7-Shaft hole for test current8-Shield As soon as the controller enters into normal run state ,the shield need to be sealed to protect the setting parameter.
ECW-M(applicable to CDW72000/3200/6300)
Standard: IEC 60947-2
ECW-M
1
2
3
4
5
6
7
8
CDW7 Air Circuit Breaker
68
Low-voltage
Distribution
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
SPECIFICATION1-Mechanical reset button(the button will pop up when fault tripping or test tripping, circuit breaker won’t be closed without pressing down,when the button is pressed down,fault indication is reset immediately)2-LCD display screen3-Warn and alarm reset4-Warn/ alarm LED When normally operated, LED is off When fault tripping , red LED will blink quickly When alarming, red LED is opening eternally5-“Healthy” LED:green LED will blink continuously as long as the controller is energized and operating healthily6-Communication lamp Communication status is indicated as follows Profibus:off when without communication,on uninterrupted when in communication Modbus:off when without communication,blinking when in communication Device Net:blinking when without communication,on uninterrupted when in communication7-Curve LED A red LED lamp is hided in curve When triped by failure , the regarding LED will blink to indicate the failure type, when the protection reference is set, the lighting LED will indicate the set option8-There is a 16pin test connector in the bottom of front plate of test terminal,you can insert a plug-in portable power box and inspection -unit
Keypad 9-Measurement function key1, navigated to measurement default theme menu10-Setting function key2, navigated to parameter setting theme menu11-Protection function key3, navigated to protection parameter setting theme menu12-Information function key4, navigated to history and maintenance theme menu13-Move upwards from the current used level to change the menu content,or change the selected parameter14-Move downwards from the current used level to change the menu content,or change the selected parameter15-Exit the current used level to back the parent menu,or cancel the current parameter16-Choose to enter the currrent programme leading to son menu,or select the current parameter, store the modification
ECW-H (enhanced type ,applicable to CDW7 2000/3200/6300)
ECW-H
RESET
Warn/ Alarm
Healthy
Bus
TEST
1
2
3
4
5
6
7
8
9 10 11 12
13 14 15 16
Isd
Ir1
Ir2
Ir4
Ir3
ELECTRIC
69
Distribution
Low
-voltage
ECWS- H
ECW series intelligent controller function feature
Intelligent controller function
Different curves available
for long time delay
protection
Different curves available
for inverse short time
delay protection
Definite short time delay
protection
Instantaneous protection
Current unbalance (open
phase) protection
Earth protection
Earth fault alarm
Neutral phase protection
Load monitor
ECW - M
ECW - H
DO Signal alarm functionMCR and out-of-limit tripping protectionEarth fault or leakage protection (either)
Over-voltage protectionUnder-voltage protectionVoltage unbalance protectionOver-currency protectionUnder-frequency protectionPhase protectionInverse power protectionDemand protectionZonal system interlock protectionCommunication function
Long time delay protection
Definite time delay +
inverse time delay for
short time delay protection
Instantaneous protection
Earthing protection
Load monitor
Different curves available
for long time delay
protection
Different curves available
for inverse short time
delay protection
Definite short time delay
protection
Instantaneous protection
MCR and out-of-limit
tripping protection
Current unbalance (open
phase) protection
Earth protection
Earth fault alarm
Neutral phase protection
Load monitor
Max. phase currentFour phase current (I1, I2, I 3, IN) and earth current
Four phase current (I1, I2, I 3, IN) and earth currentThermal capacity
Digital displayLED indicationKey operationDigital setting of protection parameters
LCD display of Chinese GUILED indicationKey operation
Fault logSelf-diagnosis functionFeature test function
Up to 8 fault logsUp to 8 alarm logsUp to 8 position logsHistorical current peakContact equivalenceNumber of operating cyclesFault clock functionSelf-diagnosis fault logSelf-diagnosis functionFeature test function
note:* can measure voltage,frenquency,voltage unbalance rate,phase-sequency detection, power,energy,demand paramteter(current,power),harmonic
Basic functionProtection
Addtional function* Human-machine DigitalMaintenanceMeasurement
Four phase current (I1, I2, I 3, IN) and earth currentThermal capacity
Up to 8 fault logsUp to 8 alarm logsUp to 8 position logsHistorical current peakContact equivalenceNumber of operating cyclesClock functionSelf-diagnosis function
LCD display of Chinese GUILED indicationKey operation
MCR and out-of-limit tripping protectionDO Signal alarm functionCommunication function
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
70
Low-voltage
Distribution
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
ECW-H intelligent controllers
Ir1=(0.4~1)ln
≥2h≤1h15,30,60,120,240,360,480,600,720,840,960
8.4,16.9,33.8,67.5,135,202.5,270,337.5,405,472.5,540
Ir2=(1.5~15)In ±10%Ts=K/10(N2-1),(Ts≥20ms)0.1,0.2,0.3,0.40.06,0.13,0.2,0.27
Ir4=(0.2~1.0)In±10%
0.1s~1s(Rank difference 0.1s)
Basic protectionLong time
Basic configuration of ECW intelligent controllerCurrent Setting
Actioncharacteristics
Short timeCurrent settingAccuracyActioncharacteristics
Instantaneous
Current settingAccuracyEarth faultCurrent settingAccuracyActioncharacteristics
CDW7-1000ECWS-H intelligent controllersIr1=(0.4~1)ln
≥2h≤2h8,12.8,19.2,32,48,64,80,108,144,224,320,480,640,800,960,11203.32,5.32,8.00,13.32,20.00,26.66,33.30,45.00,60.00,93.32,133,200,266,333,400,4331.25,2.00,3.00,5.00,7.50,10.0,12.5,16.8,22.5,35.0,50.0,75.0,100,125,150,162
Ir2=(1.5~15)In±15%Ts=K/10(N2-1),(Ts≥20ms)0.1,0.2,0.3,0.40.06,0.13,0.2,0.27
1.05×Ir1 h1.3×Ir1 h1.5Ir1
2.0Ir1
3.0Ir1
Time setting(S)Resettable time(S)
Time setting
conventional non-trippingconventional tripping
Inverse time-limitDefinite time-delay
Inverse time-limitDefinite time-delay
note:*pick-up shall not be crossed due to having three-stage protection simultaneously
CDW7-2000~6300ECW-M intelligent controllers
Ir1=(0.4~1)ln
≥2h≤1h15,30,60,120,240,480
8.4,16.9,33.8,67.5,135,270
Ir2=(0.4~15)In ±10%I2Ts=(8Ir1)2ts0.1,0.2,0.3,0.40.06,0.16,0.25,0.34
Ir4=(0.2~1.0)In±10%
0.1~0.4s (Rank difference 0.1s)
ECW-MCDW7-2000Ir3=1In~50KA+OFF±15%
ECWS-H ECW-HCDW7-1000~6300A(1.0~20)ln±15%
Ir4=(0.2~1.0)In±10%
0.1s~1s (Rank difference 0.1s)
CDW7-3200Ir3=1In~75KA+OFF±15%
CDW7-6300IIr3=1In~100KA+OFF±15%
71
Distribution
Low
-voltage
undervoltage releaseThe undervoltage release automatically opens a circuit breaker when voltage drops to a value ranging between 35% to 70% of the line voltage. after tripping,the circuit breaker cannot be re-closed again when the voltage lowers than 35% or until returns to 85% of line voltage.
Undervoltage releaseRated operational voltage Ue V Operation voltage V Range of closing voltage VRange of non-closing voltage VConsumption CDW7-2000~6300 CDW7-1000
AC 380V (0.35~0.7)Ue(0.85~1.1)Ue≤0.35Ue36VA5VA
Shunt releaseThe shunt release shall open the circuit breaker when the supply drops to a value ranging between voltage rise between 70% to 110% of the line voltage
AC380 AC220 DC220 DC11036VA 24VA 24W 24W5VA 5VA 5W 5W(0.7~1.1)Usless than 30ms
Closing voltage releasePower supply Us V Consumption CDW7-2000~6300 CDW7-1000 Operational voltage V Breaking time
AC380 AC220 DC220 DC11036VA 24VA 24W 24W10VA 10VA 10W 10W(0.85~1.1)Usless than 70ms
Closing voltage releaseClosing release shall close the circuit breaker when supply voltage drops to a value ranging between 85% to 110%
Auxiliary Functions
AC220V(0.35~0.7)Ue(0.85~1.1)Ue≤0.35Ue24VA5VA
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
Shunt releasePower supply Us V Consumption CDW7-2000~6300 CDW7-1000Operational voltage V Breaking time
72
Low-voltage
Distribution
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
AC-15Four normal open four normal close6AEqual to circuit breaker operationperformance10110.3101.10.310
DC-13
1116Pe*1.11.16Pe*10
AC380 AC220 DC220 DC11085VA 85VA 85VA 85VA110VA 110VA 110VA 110VA150VA 150VA 150VA 150VA80VA 80VA 80VA 80VA(0.85~1.1)Usless than 5s
Electric motorMotor operator shall complete energy storage when line voltage rise to between 85% to110%
Auxiliary switch
Utilizaiton categoryAuxiliary contact default typeConventional thermal current IthAuxiliary contact's energized operationalperformanceMaking&breakingcapacity
note:* when Pe≥50W,T0.95e’s upper limit≤300ms
I/Ie makingI/IebreakingU/UecosΦor T0.95I/IeU/UecosΦor T0.95operation cycles
In≤2000A2000A<In≤3200A3200A<In≤6300A
Making and breaking capacity of auxiliary contact under normal or abnormal conditions
Motor operator structureRated control power supply volage Us V
Power consumption
Operational voltage VEnergy storage time
CDW7-2000~6300
CDW7-1000
Undernormalconditions
Underabnormalconditions
73
Distribution
Low
-voltage
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
Current rating (A)200, 400630800, 1000200, 400630800, 1000
Overall DimensionUnit:mm
CDW7-1000A fixed circuit breaker overall and mounting dimension horizonal/vertical connection diagram
CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension Pole3P
4P
N6121281616
L2---707070
L1244244244314314314
L266266266336336336
74
Low-voltage
Distribution
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
Current rating (A)200, 400630800, 1000200, 400630800, 1000
CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring Pole3P
4P
L284284284354354354
L1194194194264264264
L3557575557575
L4638383638383
L2---707070
N6121281616
H68106810
CDW7-1000A drawout circuit breaker overall and horizonal/vertical connection diagram
75
Distribution
Low
-voltage
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
CDW7-2000A fixed circuit breaker vertical connection diagram
TypeCDW7-2000*
CDW7-3200
CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical wiring
a1015202030
note:* CDW7-2000 mounting dimension is same regardless of different current used in"horizonal-wiring" or"vertical-wiring"
Pole3P4P
3P4P
L1362457457422537
CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical connection dimension(CDW7-2000)
In A400~8001000~160020002000~25003200
L4340435435400515
L3292292292352352
L2318413413378493
76
Low-voltage
Distribution
Standard: IEC 60947-2
CDW7 Air Circuit Breaker
door
77
Distribution
Low
-voltage
Standard: IEC 60947-2
CDW7 Air Circuit Breaker
TypeCDW7-2000 1)
CDW7-3200
CDW7-6300(4000/5000A)CDW7-6300
CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection In A400~8001000~160020002000~25003200~400040005000~63005000~6300
Pole3P
4P3P4P3P4P3P
L1375375470435550813928928
L2335335430395510773888888
L3292292292352352352352352
L4265265360325440703818818
L5247247247307307307307307
W1461461461471471494494494
W2507507507517517540540540
note: 1) CDW7-2000 the mounting dimension is same regardless of different current used in"horizonal-connected" or "vertical-connected"
CDW7-2000~6300 panel cut-out dimension and mounting dimension Type
CDW7-2000CDW7-3200CDW7-6300
a
306366366
b
346406406
c3P0 0189(4000/5000A)246.5(6300A)
CDW7-1000 panel cut-out dimension
CDW7-2000~6300 panel cut-out dimension
a1015202030203030
CDW7-1000A fixed type CDW7-1000A drawout type
CDW7-2000~6300A drawout typeCDW7-2000~6300A fixed type
4P47.557.5246.5(4000/5000A)--
b179179179189189212212212
78
Low-voltage
Distribution
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
■ ECWS-H type intelligent release unit connection diagram
■ Sign interpretation in connection diagram:----Connected by userSB1 shunt pushbutton(self-prepared)SB3 undervoltage pushbutton(self-prepared)FU fuseDF auxiliary switchM electric motor lamp(self-prepared)
□ 41、42 when controller power choose DC,the output is DC24V,user can select DC power module
□ 43、44 circuit breaker status detection terminal(used when MCR function included)□ 45 overload pre-alarm signal output□ 46 automatic diagnosis alarm signal output□ 47 fault trip alarm signal output□ 48 earthing but non-tripping,only alarm signal output□ 49 four groups of contacts output common terminal□ 50、51 externally sensor input terminal□ 58 able to directly connect to power supply(automatic pre-energization),also able
to join up with normal open pushbutton to connect to power supply(manual pre-energization)
■ 1:Q、F、X with different current ratings shall connect with different sources.■ 2:If users have special requirements£¬the auxiliary switches can reach up to a maximum of 6ON6OFF. At this condit ion, the 45 - 49 output terminals will become the auxiliary switch contacts. For the detailed wiring diagram , please see the dotted line part of the diagram. At this time, the external sensor and supplementary functions are not available.
Auxiliary connection diagramn
----Connected by manufacturerSB2 close pushbuttonX closing voltage releaseF closing voltage releaseSA electrical path switchQ undervoltage instantaneous (or time-delay) releaseXT circuit breaker wiring terminal
79
Distribution
Low
-voltage
■ ECW-M intelligent release connection diragram
Pin functions:Pin 1# and 2#: Auxiliary power input,pin 1# is positive for DC inputPin 3#, 4#, 5#: Fault trip contact output (4# is common terminal); contact capacity: AC380V, 16APin 6# and 7#, 8# and 9#: Two groups of auxiliary contacts for breaker status; contact capacity: AC380V, 16A12#,13#(Contact1)and 14#,15#(Contact2)and 16#,17#(Contact3)and 18#,19#(Contact4):Output of four groups of signal for controllers,contact capacity:4A/240V 7A/24VDC20#: Earth protection21#~24#:input of voltage signal (Note:the order cant be wrong)
Note: 1. If the control voltage values of Q, F, X, and M are different to each other, these components can be connected to different power supply units; in the applica-tion, the shunt release and closing electromagnet shall be connected serially with normally open and normally closed auxiliary contacts (the part enclosed by dotted lines shall be connected by the user; the part represented by a two-dot chain line is the wiring of circuit 51); Note 2: The pin 35# can be connected to the power supply directly (automatic pre-energy storage) or connected serially to a normally open button and then to the power supply (manual pre-energy storage); Note 3: If the user requests, pin #6~#7 can be connected to normally closed con-tacts; Note 4: The ECW power supply module I is a DC power supply module, and it can be omitted if the power supply is AC power supply; the polarity and lead-ins/lead-outs shall not be reversed (for draw-out type circuit breakers, the lead-outs of the power supply module has been connected before the circuit break is shipped from the fac-tory); Note 5: In case of circuit 47, the auxiliary contacts are four closed and four open contacts; pin #25 and #26 are input terminals of an external current transformer , used for earth fault protection as (3P+N)T type ; Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open contacts (or five closed and five open contacts); pin #25, #26, and #51 form normally open and normally closed contacts; Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module and other conversion modules must be ordered; ECW power supply module lV and ECW201 relay module must be ordered separately; Note 8:Pin #12~#19 input/output contacts can be user-defined programmable signal contacts.
Components:Q - Under-voltage releaseF - Shunt releaseX – Closing electromagnetDF - Auxiliary switchM - MotorSB1—Button for closingSB2—Button for shunt
Standard: IEC 60947-2
CDW7 Air Circuit BreakerStandard: IEC 60947-2
CDW7 Air Circuit Breaker
80
Low-voltage
Distribution
■ Pin function:□ 1#、2#: 1# is the front terminal when DC is supplied by auxiliary power□ 3#、4#、5#:
fault trip contact output(4 is the common termincaoln)contact capacit: AC380V、16A□ 6#、7#和8#、9#:
two groups of circuit breaker status auxiliary terminal: contact capacit:AC380V、16A□ 10#、11#: respectively as the communication leading-out of RS485A ,RS485B□ 12#: overload pre-alarm signal output□ 13#: communication remote control shunt release output□ 14#: communication remote control closing output or instantaneous short time-delay
trip signal output□ 15#: communication remote control energy storage or long time-delay trip signal output□ 16#: S-earth(RS-485 transmissionn common ground wire□ 17#: load monitor output1□ 19#: signal output common earth wire□ 21#: neutral voltage signal N phase□ 23#: voltage signal B phase
■ ECW-H intelligent release connection diagram
■ components:Q- undervoltage releaseF- shunt releaseX- closing voltage releaseDF- auxiliary switchM- electric motor
■ 1: different power supply can be connected respectively if the control supply voltage of Q、F、X、M are different the shunt release、closing release shall respectively,join up with normal open、normal close auxiliary contacts(the broken line part of diagram is connected by user own;double point line is 51 circuit connection)
■ 2: terminal 35# can directly connect to power supply(automatic pre-energy storage),or join up with normal open pushbutton to connect power supply(manual pre-energy storage)
■ 3: terminal 6#~7# can lead out normal close contact if user suggested
■ 4: ECW power supply module is DC power supply module,the module doesn't exist when power supply current is AC,polarity,incoming line and leading-out line shall not connected reversely(leading-out terminal of power supply module in drawout type had been connected before sale)
■ 5: in 47 circuit,auxiliary contact is 4 open 4 close;25#、26# is input terminal of external sensor
■ 6: in 51 circuit,auxiliary contact is 6open6close(5open 5close);25#、26#、51# form normal open normal close contact(earth-leakage protection excluded)7: if using profibus or other protocols, user shall order ECW-H+HP transformation module and others;ECW power supply moduleV,ECW201 relay module and others shall order seperately
■ 8: #12~#19 output input contacts are programmableself-defined signal contaccts
□ 18#: load monitor signal 2□ 20#: PE line ,shield earth wire□ 22#: voltage signal A phase□ 24#: voltage signal C phase
■
Standard: IEC 60947-2
CDW7 Air Circuit Breaker
81
Distribution
Low
-voltage
■ ECWS-H ECW-H overcurrent proteciton curver
■ ECW-M overcurrent protection curve
Other Additional Parameter
Standard: IEC 60947-2
CDW7 Air Circuit Breaker
82
Low-voltage
Distribution
Order Instruction
Note:for any special requirement,please contact with the manufacturer.
Customer Sets purchased Date
Mode CDW7 Fixed Draw-out 3 Poles 4Poles
AC400 AC690 Rated current In= ARated voltage
H Type Intelligent electronic trip
Mechanical interlock
Accessaries
Basic function Overload long delaytime protection
Short-circuit short delay time protection
Short-circuit instantaneous protection
Earthing protection Load monitoring function(Not available for L type)
Metering function
Power supply AC 230V AC 400V DC 220V DC 110V
Under-voltage trip
Under-voltage instantaneous trip
Under-voltage time-delay trip
AC 230V AC 400V
1s 3s 5s
AC 230V AC 400V DC 220V DC 110V
AC 230V AC 400V DC 220V DC 110V
AC 230V AC 400V DC 220V DC 110V
Shunt trip
Energy releasing electromagnet
Motor Driven
Interphase barrier
N phase external connection
Escutcheon
Earth-leakage CT(Only for cable)
Auxiliary switch
Auxiliary Connection Terminal
standard(4a4b) special(6a6b)
1-lock,1-key
Steel-cable interlock
Interlocking rod with 3 switches
2-lock,1-key
Interlocking rod with 2 switches
Door interlock(Available for Draw-out type)
3-lock, 2-key
Standard: IEC 60947-2
CDW7 Air Circuit Breaker
83
Protection
Motor C
ontrol &
Motor Control & Protection
Contents
Contactor&Thermal Overload RelayCDC17-K Mini AC Contactor
CDC17 AC Contactor
CDR17 Thermal Overload Relay
CJX2 AC Contactor
JRS2 Thermal Overload Relay
JRS1D Thermal Overload Relay
CJX2-F AC Contactor
Definite Purpose ContactorCDC9 Switching Capacitor Contactor
CDCK8 Air Condition Contactor
RelayCDZ17 Contactor Relay
CDZ8 Miniature Relay
Electronic Time Relay
XJ9 Phase Failure and Sequence Protection Relay
86-12786
89
100
106
112
117
123
128
131
128-134
135-146135
139
143
146JSZ3
84
Motor C
ontrol &
Protection
Motor Control and Protection ProductOverview
Contactor
CDC17-K
Current:6-12A Pole:3P,4P Coil Voltage:AC24-400V
CDR17-18
Setting Current:0.1-18A Trip class:10A
CDR17
Setting Current:0.1-185A Trip class:10A, 10
JRS2
Setting Current:55-630A Trip class:10A,10
JRS1D
Setting Current:0.1-93A Trip class:10A,10
JRS2
Setting Current:55-630A Trip class:10A,10
CDC17
Current:9-185A Pole:3P Coil Voltage:AC24-400V
CDC17
Current:115-1000A Pole:3P Coil Voltage:AC110-400V
CJX2
Current:9-95A Pole:3P Coil Voltage:AC36-400V
CJX2-F
Current:115-630A Pole:3P Coil Voltage:AC36-400V
Thermal Overload Relay
86
89
89
106
117
100
100
123
112
123
85
Protection
Motor C
ontrol &
Motor Control and Protection ProductOverview
Definite Purpose Contactor
Control Relay
CDCK8CDC9
CDZ8
Current: 25-45A Poles: 1P,2P Application: Air Conditioner Features: Compact Convenient and reliable connection Suitable for high-temperature enviroment
CDZ17
Contact: 13, 22, 31, 40, 04, 44, 53, 62, 71, 80
Coil Voltage: AC36-380V DC22-440V Features: Large capacity of contacts Scalable accessories Longer life
Contact: 2Z,3Z,4Z Coil Voltage: AC6-220V DC6-220V Features: PCB type and plug-in type are availble Convenient installation High sensitivity Wide range of application
128 131
135139
Current: 25-65A Poles: 3P Application: Power factor correction Features: A unique limiting module Effectively inhibit the inrush current
86
Motor C
ontrol &
Protection
Function
Order Information
24VB
110VF
127VS
220VM
380VQ
400VV
Coil voltage code
coil voltage *
Rated current(A)
6
9
12
Main contact Auxiliary contact
NO NC NO NC
3
3
4
2
3
3
4
2
3
3
4
0
0
0
2
0
0
0
2
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
0
MoterP(kW) 380V
2.2
4
4
36VC
Coil FrequencyCoil Voltage Auxiliary contact Main contactRate current Model
CDC17-K 6 30 10 * ·
Reference Description
50Hz5
Coil frequency code
coil frequency·
60Hz6
CDC17-K Mini AC ContactorStandard: IEC 60947-4-1
CDC17-K AC contactor provide:□ Remote make & break of circuits □ Frequent start and stop of motors
CDC17K63010*·
CDC17K63001*·
CDC17K64000*·
CDC17K62200*·
CDC17K93010*·
CDC17K93001*·
CDC17K94000*·
CDC17K92200*·
CDC17K123010*·
CDC17K123001*·
CDC17K124000*·
Reference
87
Protection
Motor C
ontrol &
CDC17-K Mini AC ContactorStandard: IEC 60947-4-1
Technical Data
Model
Main circuit characteristics
Rated operational current
Rated operational voltage
Rated insulation voltage
Rated conventional thermal current
Pole
Power of controlled
3-phase cage motor
Electric durabilities
Operating rate
Electric durabilities
Operating rate
Mechanical durabilities
Matched Fuse
Cable connection
Coil
Coil voltage(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
Auxliary contact
Rated conventional thermal current
Rated insulation voltage
Rated operational current
Control capacity
6
2.6
3.5
1.2
220/230, 380/400, 660/690
690
16
3, 4
1.5
2.2
3
100
1200
20
600
1000
2
4
AC 24,36,110,127,220,380,400
85%~110% Us
20%~75% Us
30
4.5
690
10
0.95
0.15
360
33
9
3.5
5
1.5
20
2.2
4
5.5
CDC17-K06 CDC17-K09 CDC17-K12
12
5
6
2
3
4
7.5
380V/400V, AC-3
380V/400V, AC-4
660V/690V, AC-3
660V/690V, AC-4
220V/230V, AC-3
380V/400V, AC-3
660V/690V, AC-3
AC-3
AC-4
Inflexible cable
Cross Section of Cable
380V, AC-15
220V, DC-13
AC-15
DC-13
RT16-16 RT16-20
A
A
A
A
V
V
A
kW
kW
kW
×104 operations
cycles/h
×104 operations
cycles/h
×104 cycles
number of piece
mm2
V
V
V
VA
VA
V
A
A
A
VA
W
88
Motor C
ontrol &
Protection
CDC17-K Mini AC ContactorStandard: IEC 60947-4-1
Working Conditions
■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures
■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
Overall Dimensions
89
Protection
Motor C
ontrol &
Standard: IEC 60947-4-1
CDC17 AC Contactor
Coil voltage code
Coil frequency code
coil voltage *
coil frequency 50Hz5
60Hz6
Order Information
Rate current (A)
0
1
0
1
0
1
0
1
0
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
1
0
1
0
1
0
1
0
1
0
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
9
12
18
25
32
40
50
65
80
95
115
150
185
225
265
330
400
500
630
800
1000
MoterP(kW) 380V
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
220
265
335
450
560
Reference Description
Coil FrequencyCoil Voltage Auxiliary contact Rate current Model
24VB
110VF
127VS
220V M
380VQ
400VV
36VC
Reference
CDC17910*
CDC17901*
CDC171210*
CDC171201*
CDC171810*
CDC171801*
CDC172510*
CDC172501*
CDC173210*
CDC173201*
CDC174011*
CDC175011*
CDC176511*
CDC178011*
CDC179511*
CDC1711522*
CDC1715022*
CDC1718522*
CDC1722522*
CDC1726522*
CDC1733022*
CDC1740022*
CDC1750022*
CDC1763022*
CDC1780022*
CDC17100022*
Auxiliary contactNO NC
CDC17 9 10 * ·
90
Motor C
ontrol &
Protection
CDC17 AC ContactorStandard: IEC 60947-4-1
Technical Data Technical Data
380V / 400V, AC-3
380V / 400V, AC-4
660V, AC-3
660V, AC-4
380V/400V, AC-3
660V, AC-3
AC-3
AC-4
A
A
A
A
V
V
A
kW
kW
×104 operations
cycles/h
×104 operations
cycles/h
×104 cycles
V
V
V
VA
VA
W
mm2
mm2
Kg
Front mount
Side mount
Front mount
CDC17-12
12
5
8.9
2
20
5.5
7.5
1 2
CDC17-18
18
7.7
12
3.8
32
7.5
9
RT16-32
1 2
4
6
0.335
CDC17-25
25
8.5
18
4.4
40
11
15
110
11
3~4
CDR17-32
RT16-40
1 2
0.513
CDC17-9
9
3.5
6.6
1.5
380 / 400 660
690
20
4
5.5
100
1200
20
300
1000
AC 24, 36, 48, 110, 127, 220, 230, 380, 400
85%~110%Us
20%~75%Us
70
8
1.8~2.7
CDF4
-
CDLA2 or CDLA3
CDJL17-1
CDR17-18
RT16-20
1 2
2.5
4
0.315
Number of Piece
Flexible cable
Inflexible cable
Model
Main circuit characteristics
Rated operational current
Rated operational voltage
Rated insulation voltage
Rated conventional thermal current
Power of controlled
3-phase cage motor
Electric durabilities
Operating rate
Electric durabilities
Operating rate
Mechanical durabilities
Coil
Coil voltage(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
Heat dissipation
Accessories
Auxiliary contact
Time-delay block
Mechanical Interlock
Matched Relay
Matched Fuse
Cross Section of Cable
Weight
CDC17-32
32
12
21
7.5
50
15
18.5
80
800
RT16-50
1 2
6
10
0.510
91
Protection
Motor C
ontrol &
CDC17 AC ContactorStandard: IEC 60947-4-1
380V / 400V, AC-3
380V / 400V, AC-4
660V, AC-3
660V, AC-4
380V/400V, AC-3
660V, AC-3
AC-3
AC-4
A
A
A
A
V
V
A
kW
kW
×104 operations
cycles/h
×104 operations
cycles/h
×104 cycles
V
V
V
VA
VA
W
mm2
mm2
Kg
Front mount
Side mount
Front mount
Number of Piece
Flexible cable
Inflexible cable
CDC17-95
95
44
55
21.3
125
45
45
RT16-200
1 2
50 25
50 -
CDC17-50
50
24
39
12
80
22
33
RT16-80
1 2
16
25 -
CDC17-40
40
18.5
34
9
380 / 400 660
690
60
18.5
30
80
1200
20
300
800
AC 24, 36, 48, 110, 127, 220, 230, 380, 400
85%~110%Us
20%~75%Us
200
20
6~10
CDF4
-
CDLA2 or CDLA3
CDJL17-2
CDR17-95
RT16-63
1 2
10
16 -
1.14
CDC17-65
65
28
42
14
80
30
37
RT16-100
1 2
25
25 -
CDC17-80
80
37
49
17.3
125
37
45
60
600
RT16-125
1 2
50 25
50 -
1.35
Model
Main circuit characteristics
Rated operational current
Rated operational voltage
Rated insulation voltage
Rated conventional thermal current
Power of controlled
3-phase cage motor
Electric durabilities
Operating rate
Electric durabilities
Operating rate
Mechanical durabilities
Coil
Coil voltage(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
Heat dissipation
Accessories
Auxiliary contact
Time-delay block
Mechanical Interlock
Matched Relay
Matched Fuse
Cross Section of Cable
Weight
Technical Data Technical Data
92
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
380V/400V, AC-3
380V/400V, AC-4
660V, AC-3
660V, AC-4
380V/400V, AC-3
660V, AC-3
AC-3
AC-4
A
A
A
A
V
V
A
kW
kW
×104 operations
cycles/h
×104 operations
cycles/h
×104 cycles
V
V
V
VA
VA
W
mm2
mm2
Kg
Front mount
Side mount
Front mount
Number of Piece
Flexible cable
Inflexible cable
CDC17-150
150
60
110
61
150
75
100
1 2
120 -
- 25x3
CDC17-115
115
52
86
49
380 / 400 660
690
150
55
80
60
1200
20
300
600
AC110,127,220,230,380,400
85%~110%Us
20%~75%Us
559
33
9.5~14
-
CDFC17-11,CDFC17-12
-
CDJL17-3
CDR17-185
RT16-200
1 2
95 50
- 20x3
2.15
CDC17-185
185
79
118
69
210
90
110
695
45
13~15
CDC17-265
265
105
170
98
300
132
160
300
30
1198
83
18~25
RT16-400
1 2
240 -
- 32x4
6.6
Technical Data Technical Data
RT16-250
1 2
150 -
- 25x3
CDC17-225
225
85
135
82
225
110
129
600
JRS2-400
RT16-250
1 2
185 -
- 32x4
Model
Main circuit characteristics
Rated operational current
Rated operational voltage
Rated insulation voltage
Rated conventional thermal current
Power of controlled
3-phase cage motor
Electric durabilities
Operating rate
Electric durabilities
Operating rate
Mechanical durabilities
Coil
Coil voltage(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
Heat dissipation
Accessories
Auxiliary contact
Time-delay block
Mechanical Interlock
Matched Relay
Matched Fuse
Cross Section of Cable
Weight
CDC17-330
330
117
225
118
330
160
220
1 2
240 -
- 30x5
6.6
93
Protection
Motor C
ontrol &
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
380V / 400V, AC-3
380V / 400V, AC-4
660V, AC-3
660V, AC-4
380V/400V, AC-3
660V, AC-3
AC-3
AC-4
A
A
A
A
V
V
A
kW
kW
×104 operations
cycles/h
×104 operations
cycles/h
×104 cycles
V
V
V
VA
VA
W
mm2
mm2
Kg
Front mount
Side mount
Front mount
Number of Piece
Flexible cable
Inflexible cable
CDC17-500
500
147
355
145
500
265
335
JRS2-630
RT16-630
185
40x5
CDC17-800
800
242
530
215
800
450
500
600
RT17-4/1000
-
60x5
CDC17-630
630
188
460
170
800
335
450
1050
12
10~18
-
RT16-800
240
50x5
22.8
CDC17-400
400
138
305
135
380 / 400 660
690
500
220
280
60
300
20
30
600
AC110,127,220,230,380,400
85%~110%Us
20%~75%Us
780
10
8~14
-
-
CDFC17-21
-
JRS2-400
RT16-500
2
150
30x5
9.36
Model
Main circuit characteristics
Rated operational current
Rated operational voltage
Rated insulation voltage
Rated conventional thermal current
Power of controlled
3-phase cage motor
Electric durabilities
Operating rate
Electric durabilities
Operating rate
Mechanical durabilities
Coil
Coil voltage(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
Heat dissipation
Accessories
Auxiliary contact
Time-delay block
Mechanical Interlock
Matched Relay
Matched Fuse
Cross Section of Cable
Weight
CDC17-1000
1000
-
580
-
1000
560
560
RT17-4/-1250
80x5
Technical Data Technical Data
94
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
CDC17-9~95 Contactor Accessories
Thermal overload relays
Contactor
Top of auxiliarycontact
Air delay head
Mechanicalinterlockingmodule
Thermal overload relays
9 12 18 25 32 40 50 65 80 95
2 Poles:CDF411,CDF402,CDF4204 Poles:CDF404,CDF413,CDF422,CDF431,CDF440
Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4
CDJL171,CDJL17265,CDJL17295
CDR17-959-10-12A…75-80-95A
CDR17-324.5-5-6.3A…23-25-32
CDR17-180.1-0.13-0.15A…14-16-18
Mechanical interlocking module
Top of auxiliary contact
Air delay head
95
Protection
Motor C
ontrol &
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
Side auxiliarycontact
Top of auxiliary contact
Air delay head
Mechanical interlocking module
Thermal overload relays
CDC17-115~1000 Contactor Accessories
Contactor
Top of auxiliarycontact
Air delay head
Side auxiliarycontact
Mechanicalinterlockingmodule
Thermal overload relays
115 150 185 225 265 330 400 500 630 800 1000
2 Poles:CDF411,CDF402,CDF4204 Poles:CDF404,CDF413,CDF422,CDF431,CDF440Only applicable for CDC17-115~330
Making time-delay:CDLA2DT0,CDLA2DT2,CDLA2DT4Breaking time-delay:CDLA3DT0,CDLA3DT2,CDLA3DT4Only applicable for CDC17-115~330
CDFC1711,CDFC1721,CDFC1712Only applicable for CDC17-115~500
CDJL173150,CDJL173225,CDJL173330Only applicable for CDC17-115~330
JRS2-40080-125A…250-400A
JRS2-630320-500A400-630A
JRS2-18055-88A…150-180AOnly applicable for CDC17-115~630
96
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
Accessories
1
0
2
0
1
2
3
4
NO
1
2
0
4
3
2
1
0
NC
CDF4 Top of auxiliary contact
Pole ContactWiring diagram Reference
2P
4P
Recommended Contactor
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDC17 115~330
0.1-3S
0.1-30S
10-180S
0.1-3S
0.1-30S
10-180S
CDLA2ON0
CDLA2ON2
CDLA2ON4
CDLA3OFF0
CDLA3OFF2
CDLA3OFF4
CDLA Air delay head
Delay Type Wiring diagram
Making time-delay
Breaking time-delay
Delay Range Reference
CDFC17 Side auxiliary contact
NO NC
1
2
1
1
1
2
CDFC1711
CDFC1721
CDFC1712
PoleContact
Wiring diagram Reference
2P
3P
CDC17 115~330
CDC17 115~330
CDC17 115~330
CDF411
CDF402
CDF420
CDF404
CDF413
CDF422
CDF431
CDF440
Recommended Contactor
Recommended Contactor
13 23 31
14 24 32
97
Protection
Motor C
ontrol &
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
Accessories
Mechanical interlocking module
Working Conditions■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures
■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
CDC17-9~32A
CDC17-40~65A
CDC17-80~95A
CDC17-115~150A
CDC17-185~225A
CDC17-265~330A
CDJL171
CDJL17265
CDJL17295
CDJL173150
CDJL173225
CDJL173330
Contactor Specifications Reference
98
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
Overall Dimensions
CDC17-9~32
CDC17-40~95
Note:C1max-Contactor+CDF4 C2max-Contactor+CDLA
TypeCDC17-9~12CDC17-18CDC17-25CDC17-32CDC17-40~65CDC17-80~95
Amax454556.556.57585
Cmax77829195115123
Bmax68687979127127
C1max109115124127145153
C2max133138149152170178
a35±0.21
40±0.21
40±0.21
b59±0.28
66±0.43
105±0.57
c4.5
4.5
6.5
3 d
2- da
99
Protection
Motor C
ontrol &
Standard: IEC 60947-4-1
CDC17 AC ContactorStandard: IEC 60947-4-1
CDC17 AC Contactor
CDC17-115~150
CDC17-185~330
CDC17-400~500
TypeCDC17-185CDC17-225CDC17-265, 330
A138138171
B180199207
A1111111144
C163163201
C19595119
a1404848
a2202525
a3808096
b1158172180
b2154172180
CDC17-630~1000
Φ
91111
Φ17711
b3150150166
4848
100
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload Relay
18
32
690
690
CDR17-18
CDR17-32
0.1~0.13~0.150.12~0.16~0.180.18~0.2~0.250.25~0.32~0.360.35~0.4~0.50.5~0.6~0.70.63~0.72~0.90.9~1~1.21.2~1.6~1.81.8~2~2.52.5~3.2~3.63.5~4~4.84.5~5~6.35~6~76.3~7.2~99~10~1211~13~1514~16~184.5~5~6.35~6~76.3~7.2~99~10~1212~16~1818~20~2523~25~32
CDR1718P15CDR1718P18CDR1718P25CDR1718P36CDR1718P5CDR1718P7CDR1718P9CDR17181P2CDR17181P8CDR17182P5CDR17183P6CDR17184P8CDR17186P3CDR17187CDR17189CDR171812CDR171815CDR171818CDR17326P3CDR17327CDR17329CDR173212CDR173218CDR173225CDR173232
Order Information
CDR17 18 P15
Reference Description
Setting current Rated current Model
Function CDR17 series thermal overload relay provide:□ Protection of circuits and motors against overload□ Protection of circuits and motors against phase loss□ Motor starters installation in association with contactors
RatedinsulationvoltageUi V
Frame sizerated current
Type Range of currentsetting A
Recommended contactorReference
CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-9~18CDC17-25~32CDC17-25~32CDC17-25~32CDC17-25~32CDC17-25~32CDC17-25~32CDC17-25~32
101
Protection
Motor C
ontrol &
Order Information
95
185
690
690
9~10~1212~16~1818~20~2523~25~3230~36~4037~45~5048~55~6555~63~7063~70~8075~90~9537~45~5048~55~6555~63~7063~70~8075~90~9590~100~115105~115~135120~135~150130~150~160150~160~185
CDR17-95
CDR17-185
CDR179512CDR179518CDR179525CDR179532CDR179540CDR179550CDR179565CDR179570CDR179580CDR179595CDR1718550CDR1718565CDR1718570CDR1718580CDR1718595CDR17185115CDR17185135CDR17185150CDR17185160CDR17185185
CDC17-40~95CDC17-40~95CDC17-40~95CDC17-40~95CDC17-40~95CDC17-40~95CDC17-40~95CDC17-40~95CDC17-40~95CDC17-40~95CDC17-115~185CDC17-115~185CDC17-115~185CDC17-115~185CDC17-115~185CDC17-115~185CDC17-115~185CDC17-115~185CDC17-185CDC17-185
RatedinsulationvoltageUi V
Frame sizerated current
Type Range of currentsetting A
Recommended contactorReference
Standard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload Relay
102
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload Relay
Technical Data
AC-15
50
690
220/230
1.64/1.57
6
AC-15
50
690
660/690
6
6
50
690
380/400
0.95/0.9
6
50
690
660/690
0.55/0.52
6
690
220/230
0.23/0.22
6
DC-13
-10℃~+55℃
CDR17-18, 32, 95
CDR17-185
690V
Yes
Yes
Yes
Yes
Yes
Yes
Yes
±22.5°
DC-13
690
220/230
6
6
Temperature compensation
Trip class 10A
10
Rated insulation voltage Ui V
Structure characteristics
Overload protection
Phase-failure protection
Manual reset
Automatic reset
Stop button
Test button
Trip direction
Tolerance on slope in any direction
Control circuit
Utilization category
Rated frequency Hz
Rated insulation voltage Ui V
Rated operational voltage Ue V
Rated operational current Ie A
Conventional free air thermal current Ith A
Contact circuit
Utilization category
Rated frequency Hz
Rated insulation voltage Ui V
Rated operational voltage Ue V
Rated operational current Ie A
Conventional free air thermal current Ith A
103
Protection
Motor C
ontrol &
SequenceMultiples of setting current
Trip timeInitial condition
Ambient temperatureTrip class 10A Trip class 10
Limits of operation of relays when energized on all poles
1 1.05 >2h >2h From cold state +20℃
2 1.2 <2h <2h
From hot state(immediately following sequence 1 test)
3 1.5 <2min <4min
From hot state(immediately following sequence 1 test)
4 7.2 2s<Tp≤10s 4s<Tp≤10s From cold state +20℃
Limits of operation when energized on two poles
Any two poles
The third-pole
1 1.0 0.9 >2h >2h From cold state +20℃
2 1.15 0 <2h <2h
From hot state(immediately following sequence 1 test)
Trip Characteristic
Accessories
Name Reference
CDR17-18 CDR1718J
CDR17-32 CDR1732J
CDR17-95 CDR1795J
Standard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload Relay
Base Thermal Overload Relay
104
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload Relay
Work conditions
Ambient temperature: -10℃~+55℃, daily average temperature ≤35℃
Altitude: ≤2000m Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3
Installation conditions
Installation Type: Ⅲ Installation position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 22.5°
22.5 22.5
Wire Connection Picture
FU-FuseKM-ContactorFR-RelaySB1-Stop ButtonSB2-Start Button
360°
105
Protection
Motor C
ontrol &
■ CDR17-18
■ CDR17-32
Overall Dimensions
■ CDR17-95
■ CDR17-185
Standard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
CDR17 Thermal Overload Relay
106
Motor C
ontrol &
Protection
Order Information
Rated current(A)
9
12
18
25
32
40
50
65
80
95
ReferenceAuxiliary contact
NO
1
0
1
0
1
0
1
0
1
0
1
1
1
1
1
NC0
1
0
1
0
1
0
1
0
1
1
1
1
1
1
Motor P(kW) 380V
5.5
7.5
10
15
18.5
30
33
37
45
55
Coil voltage code
coil voltage*
36VC
110VF
127VS
220VM
380VQ
400VV
Coil frequency code
coil frequency·
50Hz5
60Hz6
Reference Description
Coil FrequencyCoil Voltage Auxiliary contact Rate current Model
Function CJX2 AC contactors provide:□ Remote make & break of circuits □ Frequent start and stop of motors
CJX2 AC ContactorStandard: IEC 60947-4-1
CJX2 9 10 * ·
CJX2910*·
CJX2901*·
CJX21210*·
CJX21201*·
CJX21810*·
CJX21801*·
CJX22510*·
CJX22501*·
CJX23210*·
CJX23201*·
CJX24011*·
CJX25011*·
CJX26511*·
CJX28011*·
CJX29511*·
107
Protection
Motor C
ontrol &
Standard: IEC 60947-4-1
AC-3
AC-4
AC-3
AC-4
AC-3
AC-3
AC-4
AC-3
AC-4
AC-3
AC-4
AC
DC
AC-15
DC-13
380V,
380V,
660V,
660V,
220V,
380V,
660V,
CJX2-09
380, 660
690
25
9
3.5
6.6
1.5
4
5.5
2.2
100
20
1000
1200
300
RT16-20
1.5
AC36,110,127,220,380,400
85%~110%Us
20%~75%Us
70
8
1.8~2.7
F4
FC6
SK4
10
380
220
360
33
CJX2-12
25
12
5
8.9
2
5.5
7.5
3
RT16-20
1.5
CJX2-18
32
18
7.7
12
3.8
7.5
10
4
RT16-32
2.5
CJX2-25
40
25
18
8.5
4.4
11
15
5.5
RT16-40
4
110
11
3~4
CJX2-32
50
32
21
12
7.5
15
18.5
7.5
80
20
800
600
300
RT16-50
6
CJX2-40
60
40
34
18.5
9
18.5
30
11
80
15
800
600
300
RT16-63
10
200
20
6~10
CJX2-50
80
50
39
24
12
22
33
15
RT16-80
16
CJX2-65
80
65
42
28
14
30
37
18.5
RT16-80
16
Technical Data
CJX2 AC Contactor
CJX2-80
125
80
49
37
17.3
37
45
22
60
10
600
600
300
RT16-100
25
Front mount
Side mount
Front mount
V
V
A
A
A
A
A
kW
kW
kW
×104 operations
×104 operations
×104 cycles
cycles/h
cycles/h
mm2
V
V
V
VA
VA
W
A
V
V
VA
W
Model
Main circuit characteristics
Rated operational voltage
Rated insulation voltage
Conventional thermal current
Rated operational
current
Power of controlled
3-phase cage
motor
Electric durabilities
Mechanical durabilities
Operating rate
Matched Fuse
Cable connection cross section
Coil
Coil voltage(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
Heat dissipation
Accessories
Auxiliary contact
Time-delay block
Mechanical InterlockRated conventional thermal current
Rated operational voltage
Rated control capacity
FR632H FR695HX
CJX2-95
125
95
55
44
21.3
45
55
25
RT16-125
35
108
Motor C
ontrol &
Protection
Contactor
9 12 18 25 32 40 50 65 80 95
Top of auxiliary contact
Thermal overload relays
Top of auxiliary contact
CJX2 AC ContactorStandard: IEC 60947-4-1
Thermal overload relays
JRS1D-25 0.1-0.16A ... 17-25A
JRS1D-36 23-32A 30-40A
JRS1D-93 23-32A ... 80-93A
Air delay head
Mechanical interlocking module
Side auxiliary contact
2 Poles:F411,F402,F420 4 Poles: F404,F413,F422,F431,F440
Making time-delay: SK420,SK422,SK424 Breaking time-delay: SK430,SK432,SK434
9-32A: FR632H 40-95A: FR695HX
2 Poles: FC611, FC602, FC620
Air delay head
Mechanical interlocking module
Side auxiliary contact
CJX2 Contactor Accessories
109
Protection
Motor C
ontrol &
Accessories
Standard: IEC 60947-4-1
CJX2 AC Contactor
SK4 Air delay head
Delay Type
0.1-3S
0.1-30S
10-180S
0.1-3S
0.1-30S
10-180S
Delay Range
SK420
SK422
SK424
SK430
SK432
SK434
Reference
Making time-delay
Breaking time-delay
Wiring diagram
F4 Top of auxiliary contact
1
2
0
4
3
2
1
0
NC
4P
2P
Pole
1
0
2
0
1
2
3
4
NOContact
F411
F402
F420
F404
F413
F422
F431
F440
ReferenceWiring diagram
FC6 Side auxiliary contact
NO NC
0
1
2
2
1
0
PoleContact
Wiring diagram
FC602
FC611
FC620
Reference
2P
61
62
51 61
52 62
53 63
54 64
53
54
110
Motor C
ontrol &
Protection
Standard: IEC 60947-4-1
CJX2 AC Contactor
Working Conditions
■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures
■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
Mechanical interlocking module
CJX2-9~32
CJX2-40~95
FR632H
FR695HX
Contactor Specifications Reference
Accessories
111
Protection
Motor C
ontrol &
Overall Dimensions
CJX2-09~32
CJX2-40~95
Amax
47
47
57
57
77
87Note: C1max is auxiliary contact group +F4 C2max is air-delay contact+SK4
Bmax
76
76
86
86
129
129
Cmax
82
87
97
102
116
127
C1max
115
120
130
135
149
160
C2max
115
120
130
135
149
160
a
35
40
40
b
50/60
50/60
100/110
Product Type
CJX2-09~12
CJX2-18
CJX2-25
CJX2-32
CJX2-40~65
CJX2-80~95
Unit:mm
Standard: IEC 60947-4-1
CJX2 AC Contactor
d
4.5
4.5
6.5
112
Motor C
ontrol &
Protection
Function
JRS1D Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
JRS1D relay provide:□ Protect motor and circuit□ Possess overload and phase failure protection functions.
Order Information
25
36
93
0.1~0.16
0.16~0.25
0.25~0.4
0.4~0.63
0.63~1
1~1.6
1.6~2.5
2.5~4
4~6
5.5~8
7~10
9~13
12~18
17~25
23~32
30~40
23~32
30~40
37~50
48~65
55~70
63~80
80~93
RT16-4
RT16-4
RT16-4
RT16-4
RT16-4
RT16-4
RT16-6
RT16-10
RT16-16
RT16-20
RT16-20
RT16-25
RT16-35
RT16-50
RT16-63
RT16-80
RT16-63
RT16-80
RT16-100
RT16-100
RT16-125
RT16-125
RT16-160
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-09~32
CJX2-12~32
CJX2-18~32
CJX2-25~32
CJX2-25~32
CJX2-32
CJX2-40~95
CJX2-40~95
CJX2-50~95
CJX2-50~95
CJX2-65~95
CJX2-80~95
CJX2-95
Reference Description
Setting current Rated current Model
JRS1D 25 P16
Current setting(A)
Recommended fuse
Frame size rated current(A)
Recommended contactor
Reference
JRS1D25P16
JRS1D25P25
JRS1D25P4
JRS1D25P63
JRS1D251
JRS1D251P6
JRS1D252P5
JRS1D254
JRS1D256
JRS1D258
JRS1D2510
JRS1D2513
JRS1D2518
JRS1D2525
JRS1D3632
JRS1D3640
JRS1D9332
JRS1D9340
JRS1D9350
JRS1D9365
JRS1D9370
JRS1D9380
JRS1D9393
113
Protection
Motor C
ontrol &
Technical Data
50
500
380
0.95
5
5
DC-13
50
500
220
0.15
5
5
-5℃~+40℃
JRS1D-25, 36
JRS1D-93
660V
Yes
Yes
Yes
Yes
Yes
Yes
Yes
±5°
AC-15
th
JRS1D Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
50
500
220
1.64
5
5
Temperature compensation
Trip class 10A
10
Rated insulation voltage Ui V
Structure characteristics
Overload protection
Phase-failure protection
Manual reset
Automatic reset
Stop button
Test button
Trip direction
Tolerance on slope in any direction
Auxiliary circuit
Utilization category
Rated frequency Hz
Rated insulation voltage Ui V
Rated operational voltage Ue V
Rated operational current Ie A
Conventional free air thermal current I A NO
NC
114
Motor C
ontrol &
Protection
Thermal Overload Relay Reference
JRS1D-25 JRS1D25J
JRS1D-36 JRS1D36J
JRS1D-93 JRS1D93J
Accessories
SequenceMultiples of setting current
Trip timeInitial condition
Ambient temperatureTrip class
10ATrip class 10
Limits of operation of relays when energized on all poles
1 1.05 >2h >2h From cold state +20℃
2 1.2 <2h <2h
From hot state(immediately following sequence 1 test)
3 1.5 <2min <4min
From hot state(immediately following sequence 1 test)
4 7.22s<Tp≤10s
4s<Tp≤10s From cold state +20℃
Limits of operation when energized on two poles
Any two poles
The third-pole
1 1.0 0.9 >2h >2h From cold state +20℃
2 1.15 0 <2h <2h
From hot state(immediately following sequence 1 test)
Trip Characteristic
JRS1D Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
115
Protection
Motor C
ontrol &
�c
�c
�c
Ambient temperature: -5℃~+40℃, daily average temperature ≤35℃ Altitude: ≤2000m
Pollution class: 3
y. Vertically mounting.
�c
Installation Type: Ⅲ Installation position: Unobvious shake and impact shock is necessarTolerance on slope in any direction shall not exceed 5°
5° 5°
Humidity:The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change
Installation Conditions
Work Conditions
FU-FuseKM-ContactorFR-RelaySB1-Stop ButtonSB2-Start Button
JRS1D Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
Wire Connection Picture
360°
116
Motor C
ontrol &
Protection
JRS1D-25 / Z
JRS1D-36 / Z
JRS1D-93 / Z
Unit: mm
Overall Dimensions
JRS1D Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
117
Protection
Motor C
ontrol &
CJX2-F 9 10 *
Reference Description
Coil FrequencyCoil VoltageAuxiliary contactRate currentModel
Order Information
Function CJX2-F AC contactors provide:□ Remote make & break of circuits □ Frequent start and stop of motors
CJX2-F AC ContactorStandard: IEC 60947-4-1
coil voltage
*36V
C
110V
F
220V
M
380V
Q
400V
V
Coil voltage code
Coil frequency code
coil frequency·
50Hz5
60Hz6
115
150
185
225
265
330
400
500
630
CJX2F115*
CJX2F150*
CJX2F185*
CJX2F225*
CJX2F265*
CJX2F330*
CJX2F400*
CJX2F500*
CJX2F630*
55
75
90
110
132
160
200
250
335
Rated current (A) ReferenceMotor P(kW) 380V
118
Motor C
ontrol &
Protection
Technical Data
AC
DC
AC-15
DC-13
cooper
conductor
cooper bar
number of Piece
cross section
number of Piece
dimension
380V, AC-3
380V, AC-4
660V, AC-3
660V, AC-4
380V, AC-3
380V, AC-4
660V, AC-3
660V, AC-4
AC-3
AC-4
CJX2-F185
275
185
79
118
69
90
40
110
63
600
100
600
120
RT16-425
1
150
/
/
800
55
24
CJX2-F225
275
225
85
137
82
110
45
129
75
600
100
600
120
RT16-500
1
150
/
/
800
55
24
CJX2-F265
315
265
105
170
98
132
55
160
90
600
80
600
120
RT16-630
1
185
/
/
1200
13
12
CJX2-F330
380
330
117
235
118
160
63
220
110
600
80
600
120
RT16-800
1
240
/
/
1200
13
12
CJX2-F400
450
400
138
303
135
200
72
280
129
600
80
300
120
RT16-800
2
150
2
30×5
1200
20
14
CJX2-F500
630
500
147
353
145
250
80
335
140
600
80
300
120
RT17-1000
2
185
2
40×5
1250
24
18
CJX2-F150
200
150
60
108
61
75
30
100
55
1000
120
600
120
RT16-355
1
95
/
/
550
45
16
CJX2-F AC ContactorStandard: IEC 60947-4-1
CJX2-F630
800
630
188
462
170
335
100
450
160
600
80
300
120
RT17-1250
2
240
2
50×5
1650
22
20
Model
Main circuit characteristics
Rated operational voltage
Rated insulation voltage
Rated conventional thermal current
Rated operational
current
Power of controlled
3-phase cage motor
Mechanical durabilities
Electric durabilities
Operating rate
Matched Fuse
Cable
connection
Coil
Rated voltage power control(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
Heat dissipation
Auxliary contact
Rated conventional thermal current
Rated operational
voltage
Rated control capacity
V
V
A
A
A
A
A
kW
kW
kW
kW
×104 cycles
×104 operations
cycles/h
cycles/h
mm2
V
V
V
VA
VA
W
A
V
V
VA
W
CJX2-F115
1000
380,660
200
115
52
86
49
55
25
80
45
1000
120
600
120
RT16-250
1
95
/
/
AC36,110,220,380,400
85%~110%Us
20%~75%Us
550
45
16
10
380
220
360
33
119
Protection
Motor C
ontrol &
CJX2-F AC ContactorStandard: IEC 60947-4-1
Top of auxiliary contact
Air delay head
Thermal overload relays
CJX2-F Contactor Accessories
Contactor
Top of auxiliary contact
Air delay head
Thermal overload relays
2 Poles:F411,F402,F420 4 Poles: F404,F413,F422,F431,F440
Making time-delay : SK420,SK422,SK424 Breaking time-delay : SK430,SK432,SK434
JRS2-180 55-88A ... 150-180A
JRS2-400 80-125A ... 250-400A
JRS2-630 320-500A 400-630A
115 150 185 225 265 330 400 500 630
120
Motor C
ontrol &
Protection
Accessories
F4 Top of auxiliary contact
SK4 Air delay head
1
0
2
0
1
2
3
4
1
2
0
4
3
2
1
0
F411
F402
F420
F404
F413
F422
F431
F440
NO NC
2P
4P
Pole Contact Wiring diagram Reference
0.1-3S
0.1-30S
10-180S
0.1-3S
0.1-30S
10-180S
Delay Type Delay Range Reference
Making time-delay
Breaking time-delay
Wiring diagram
SK420
SK422
SK424
SK430
SK432
SK434
CJX2-F AC ContactorStandard: IEC 60947-4-1
121
Protection
Motor C
ontrol &
Working Conditions
■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures
■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
CJX2-F AC ContactorStandard: IEC 60947-4-1
122
Motor C
ontrol &
Protection
Overall Dimensions
CJX2-F AC ContactorStandard: IEC 60947-4-1
HaModel Amax Bmax Cmax P S F M H L X1(200~500v) (600~1000v)
X1 Ga
CJX2-F115
CJX2-F150
CJX2-F185
CJX2-F225
CJX2-F265
CJX2-F330
CJX2-F400
CJX2-F500
CJX2-F630
167
167
171
171
202
213
213
233
309
163
171
174
197
203
206
206
238
304
80
80
80
80
96
96
80
80
180
15
15
15
15
15
15
20
20
30
10
10
10
10
10
10
15
15
20
107
107
103.5
103.5
141
145
145
146
155
124
124
127
127
147
158
158
172
202
147
150
154
172
178
181
181
208
264
131
131
131
131
147
147
146
150
181
M6
M8
M8
M10
M10
M10
M10
M10
M12
20
20
20
25
25
25
25
30
40
37
40
40
48
48
48
48
55
80
172
172
183
183
215
220
220
233
256
110~1120
110~1120
110~1120
110~1120
110~1120
110~1120
170~1180
170~1180
170~1180
CJX2-F115~330
CJX2-F400~500
CJX2-F630
Unit: mm
123
Protection
Motor C
ontrol &
Function
JRS2 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
JRS2 relay provide:□ Protect motor and circuit□ Possess overload and phase failure protection functions.
JRS2 12P5 P16
Reference Description
F:Installed independently
Setting current
Rated current
Model
Order Information
Frame size rated current( A )
Current setting(A) Reference Recommended fuse
180
400
630
55~88
63~90
80~110
90~120
110~135
120~150
135~160
150~180
80~125
125~200
160~250
200~320
250~400
320~500
400~630
JRS218088F
JRS218090F
JRS2180110F
JRS2180120F
JRS2180135F
JRS2180150F
JRS2180160F
JRS2180180F
JRS2400125F
JRS2400200F
JRS2400250F
JRS2400320F
JRS2400400F
JRS2630500F
JRS2630630F
-125
-125
-200
-200
-200
-200
-250
-250
-200
-400
-400
-500
-500
-630
-630
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
RT16
124
Motor C
ontrol &
Protection
JRS2 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
JRS2 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
Temperature compensation
10A
10
Rated insulation voltage Ui V
Structure characteristics
Overload protection
Phase-failure protection
Manual reset
Automatic reset
Stop button
Test button
Trip direction
Tolerance on slope in any direction
Utilization category
Rated frequency Hz
Rated insulation voltage Ui V
Rated operational voltage Ue V
Rated operational current Ie A
Conventional free NO
NC
-5℃~+40℃
JRS2-180
JRS2-400, 630
660V
Yes
Yes
Yes
Yes
Yes
Yes
Yes
±5°
5
5
5
5
5
5
50
380
220
1.64
50
380
380
0.95
DC-13
50
500
220
0.16
Auxiliary circuit
AC-15
Trip class
125
Protection
Motor C
ontrol &
JRS2 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
JRS2 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
SequenceMultiples of setting current
Trip timeInitial condition
Ambient temperatureTrip class
10ATrip class 10
Limits of operation of relays when energized on all poles
1 1.05 >2h >2h From cold state +20℃
2 1.2 <2h <2hFrom hot state(immediately following sequence 1 test)
3 1.5 <2min <4minFrom hot state(immediately following sequence 1 test)
4 7.22s<Tp≤10s
4s<Tp≤10s
From cold state +20℃
Limits of operation when energized on two poles
Any two poles
The third-pole
1 1.0 0.9 >2h >2h From cold state +20℃
2 1.15 0 <2h <2hFrom hot state(immediately following sequence 1 test)
Trip Characteristic
126
Motor C
ontrol &
Protection
JRS2 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
Work Conditions
Ambient temperature: -5℃~+40℃, daily average temperature ≤35℃ Altitude: ≤2000m Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum temperature reaches +40℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change Pollution class: 3
Installation Conditions
Installation Type: Ⅲ Installation position: Unobvious shake and impact shock is necessary. Vertically mounting. Tolerance on slope in any direction shall not exceed 5°
5° 5°
Wire Connection PictureFU-FuseKM-ContactorFR-RelaySB1-Stop ButtonSB2-Start Button
360°
127
Protection
Motor C
ontrol &
Overall Dimensions
JRS2 Thermal Overload RelayStandard: IEC 60947-4-1 IEC 60947-5-1
■ JRS2-180/F
■ JRS2-400~630/F
50 50
171
146
25x4
10.570
Unit: mm
128
Motor C
ontrol &
Protection
CDC9 Switching Capacitor ContactorStandard: IEC 60947-4-1 IEC 60947-5-1
Order Information
CDC92511*·
CDC92520*·
CDC92502*·
CDC93211*·
CDC93220*·
CDC93202*·
CDC94311*·
CDC94320*·
CDC94302*·
CDC96312*·
CDC96321*·
CDC99512*·
CDC99521*·
Rated current(A)
25
32
43
63
95
ReferenceAuxiliary contact
NO
1
2
0
1
2
0
1
2
0
1
2
1
2
NC1
0
2
1
0
2
1
0
2
2
1
2
1
CDC9 9 10 * ·
Reference Description
Coil FrequencyCoil Voltage Auxiliary contact Rate current Model
380V
Q
400V
V
Coil voltage code
36V
C
110V
F
127V
S
220V
M
Coil frequency code
50Hz5
60Hz6
coil voltage *
Function CDC9 switching capacitor contactors provide:□ Switch three-phase unipolar or multipolar capacitor group,to improve their power factor□ Reduce the current closing of the impact of capacitor
coil frequency·
129
Protection
Motor C
ontrol &
CDC9 Switching Capacitor ContactorStandard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
380V, AC-6b
220V, AC-6b
380V, AC-6b
380V, AC-6b
380V, AC-6b
V
V
A
Kvar
Kvar
A
×104 operations
×104 operations
operations/h
mm2
V
V
V
A
CDC9-32
23
9
18
32
CDC9-43
29
10
20
43
CDC9-63
43
15
30
63
CDC9-95
400
63
22.5
45
95
120
Model
Main circuit
Rated operational voltage
Rated insulation voltage
Controlled capacitor rate capacity
Controlled capacitor rate capacity
Rate conventional thermal current
Control inrush current capacity
Mechanical life
Electric life
Operating frequency
Cable connection cross section
of copper conductor
Coil
Coil voltage(Us)
Operational voltage
Drop-out voltage
Auxiliary contact
Rate conventional thermal current
Minimum load can be connected
CDC9-25
380
500
17
6
12
25
≤20ln
100
10
300
4
AC36,110,127,220,380,400
85%~110%Us
20%~75%Us
10
6V×10mA
130
Motor C
ontrol &
Protection
CDC9 Switching Capacitor ContactorStandard: IEC 60947-4-1 IEC 60947-5-1
Working Conditions
■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures
■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
131
Protection
Motor C
ontrol &
Function
CDCK8 Air Condition ContactorStandard: IEC 60947-4-1 IEC 60947-5-1
CDCK8 air condition contactor provide:□ Remote make & break of circuits □ Frequent start and stop of motors
CDCK8 25 1 10 * ·
Reference Description
Coil FrequencyCoil Voltage Auxiliary contactPoleRate current Model
Order Information
Rated current(A)
25
32
45
25
32
Auxiliary contact
NO0
0
0
0
0
0
0
NC1
0
1
0
0
0
0
Pole
1P
1P
1P
2P
2P
Coil voltage *
36V
C
110V
F
220V
M
Coil frequency code
Coil frequency·
50Hz5
60Hz6
Coil voltage code
CDCK825101*·
CDCK825100*·
CDCK832101*·
CDCK832100*·
CDCK845100*·
CDCK825200*·
CDCK832200*·
Reference
132
Motor C
ontrol &
Protection
CDCK8 Air Condition ContactorStandard: IEC 60947-4-1 IEC 60947-5-1
Technical Data
CDCK8-25
690
4
220
32
25
2.5(3)
100
8
300
8le
RT16-40
6
AC36,110,220
70%~110%Us
20%~60%Us
36
4
5
220
100
CDCK8-32
40
32
3.2(4)
RT16-50
10
Model
Main circuit characteristics
Rate insulation voltage
Rated voltage shock tolerance
Rated operational voltage
Rate conventional thermal current
Rate operational current
Power of controlled
single-phase motor
Mechanical life
Electric life
Operating frequency
Short time withstand current
Matched fuse
Connecting line
Coil
Auxiliary contact
Rate conventional thermal current
Rated operational voltage V
Control capability
V
kV
V
A
A
kW(Hp)
x104 operations
x104 operations
operations/h
A
mm2
V
V
V
VA
VA
A
V
VA
Coil voltage(Us)
Operational voltage
Drop-out voltage
Inrush
Sealed
220V,
AC-8b
AC-8b
AC-8b
AC-8b
10S
AC-1
CDCK8-45
50
45
4.5(5)
RT16-63
16
133
Protection
Motor C
ontrol &
CDCK8 Air Condition ContactorStandard: IEC 60947-4-1 IEC 60947-5-1
Working Conditions■ Ambient temperature:-5℃~+40℃, the daily average temperature ≤ 35℃ ■ Altitude: ≤ 2000 m ■ Humidity: Maximum temperature is +40℃, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20℃, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special measures
■ Pollution Level: 3 ■ Installation Type: Ⅲ ■ Installation position: should be installed in the absence of a significant shake and
shock and vibration place
Install Location
134
Motor C
ontrol &
Protection
CDCK8 Air Condition ContactorStandard: IEC 60947-4-1 IEC 60947-5-1
Overall Dimensions
Product type
CDCK8-25,32
CDCK8-25/01,32/01
CDCK8-25,32
CDCK8-45
Bmax
62
69
61.5
67
Unit:mm
1P
1P
2P
1P
Pole Amax
70
70
86
85
135
Protection
Motor C
ontrol &
Function CDZ17 contactor relays provide:□ Remote make & break of circuits□ Start, stop and control of small capacity motors□ Boost signals, interlock electric, transfer signals or control various kinds of magnetic
coils
Standard: IEC 60947-5-1
CDZ17 Contactor Relay
Order Information
Rated current(A)
6
9
6
9
ReferenceContact blocks NO
1
2
3
4
0
1
2
3
4
0
4
5
6
7
8
4
5
6
7
8
NC
3
2
1
0
4
3
2
1
0
4
4
3
2
1
0
4
3
2
1
0
CDZ17613*
CDZ17622*
CDZ17631*
CDZ17640*
CDZ17604*
CDZ17913*
CDZ17922*
CDZ17931*
CDZ17940*
CDZ17904*
CDZ17644*
CDZ17653*
CDZ17662*
CDZ17671*
CDZ17680*
CDZ17944*
CDZ17953*
CDZ17962*
CDZ17971*
CDZ17980*
Coil voltage
*24V
B
36V
C
110V
F
220V
M
380V
Q
400V
V
440V
X
Coil power supply
DC
Z
AC
Default
48V
E
Coil voltage code
Coil power supply
CDZ17 9 13 M
Default: AC
Z:DCCoil voltageContact blocksRated currentModel
Reference Description
136
Motor C
ontrol &
Protection
Standard: IEC 60947-5-1
CDZ17 Contactor Relay
24
6
36
9
NO
4
5
6
7
8
24
4
36
6
NO
1
2
3
4
0
690
8000
16
12V 10mA
100
1000
3000(AC)
RT16-202.5(X2)
AC36, 110, 220, 380,400; DC24, 48, 110, 220, 440
80%~110%Us
20%~75%Us(AC) 10%~75%Us(DC)
70(AC) 7(DC)
8(AC)
2.8(AC)
0.32(Single,AC)
0.52(Single,DC)
Coil voltage(Us) V
Operational voltage V
Drop-out voltage V
Inrush VA
Sealed VA
Heat dissipation W
6A 9A
Single Double
48
2.5
110
6
110
1
220/230
6
NC
3
2
1
0
4
1200(DC)
6.5(DC)
220
0.5
380/400
4
440
0.2
690
1.5
0.36(double,AC)
0.56(double,DC)
48
3.5
110
9
110
1.5
220/230
9
NC
4
3
2
1
0
220
0.6
380/400
6
440
0.3
690
3
Technical Data
Model
Rated operational voltage V DC-13
Rated operational voltage A
Rated operational current V AC-15
Rated operational current A
Contact assemble
Rated insulation voltage V
Rated impulse withstand voltage V
Rated conventional thermal current A
Minimum load can be connected
Electric durabilities(x104 operations)
Mechanical durabilities(x104 cycles)
Operating rate(cycles/h)
Matched Fuse
Cross Section of Cable mm2 (maximum)
Coil
Weight Kg
137
Protection
Motor C
ontrol &
■ Installation Type: Ⅲ ■ Installation position: Unobvious shake and impact shock is necessary. Vertically
mounting. Tolerance on slope in any direction shall not exceed 5°
■ Ambient temperature: -15℃~+50℃, daily average temperature ≤35℃ ■ Altitude: ≤2000m■ Humidity: The relative humidity of the installtion position shall not exceed 50%
when the maximum temperature reaches +50℃. But there can be higher relative humidity under lower temperature. For example, it can reach 90% when temperature is at 20℃. Special measures should be taken against condensation occuring on product surface caused by temperature change
■ Pollution class: 3
Work Conditions
Installation Conditions
Standard: IEC 60947-5-1
CDZ17 Contactor Relay
25° 25°
138
Motor C
ontrol &
Protection
Overall Dimensions
CDZ17-80/Z,71/Z,62/Z,53/Z,44/Z
CDZ17-40, 31, 22, 13, 04
CDZ17-80, 71, 62, 53, 44
CDZ17-40/Z, 31/Z, 22/Z, 13/Z, 04/Z
Standard: IEC 60947-5-1
CDZ17 Contactor Relay
Unit: mm
139
Protection
Motor C
ontrol &
yCDZ8 Miniature Rela
Function Used to implement the conversion of intermediate control signals and low-power output, In the field of industrial control, used in conjunction with contactors, relays, circuit breakers, etc.
2 5A L AC
None AC
L DC
None DC
Accessory
3 5A L AC
None AC
L DC
None DC
Accessroy
4 3A L AC
None AC
L DC
None DC
Accessory
CDZ8052L*1
CDZ8052*1
CDZ8052L*Z1
CDZ8052*Z1
CDZ8PYF08AXXKH
CDZ8053L*1
CDZ8053*1
CDZ8053L*Z1
CDZ8053*Z1
CDZ8PYF11AXXKH
CDZ8034L*1
CDZ8034*1
CDZ8034L*Z1
CDZ8034*Z1
CDZ8PYF14AXXKH
Rated voltage code
Rated voltage*
6V
I
12V
J
24V
B
48V
E
110V
F
127V
S
220V
M
36V
C
Poles Rated Current LED Voltage Type Reference
Order Information
230V
N
140
Motor C
ontrol &
Protection
yCDZ8 Miniature Rela
Technical Data
2Z 3Z 4Z
Contact
5A 5A 3A
AC 6-220V
DC 6-220V
≤50mΩ
Silver Alloy
≥105 times (1800 Ops/h)
≥107 times (18000 Ops/h)
LED
DC:≤ 75%Ue, AC:80%Ue
DC:≥10%Ue, AC:30%Ue
110%Ue
0.9
1.2
≤20ms
≤20ms
1300VAC/1min
1500VAC/1min
1800VAC/1min
-25~+55℃
35%~85%RH
86~106KPa
10G(Sine half-wave pulse:11ms)
10~55Hz Double amplitude:1.0mm
Plug-in terminals
35g
6
40
6
11.5
12
160
12
40
24
600
24
160
36
1440
36
370
48
2600
48
600
110
11000
110
3750
220
42000
127
4100
220
14000
Form
Capacity
Nominal coil voltage
Resistance
Materials
Electrical life expectancy
Mechanical life expectancy
DC(W)
AC(VA)
Between contacts
Between
contacts(different pole)
Between Contact and coil
Type Description
Operating voltage (25℃)
Release voltage (25℃)
Maximum voltage (25℃)
Coil consumption
Operating time (Rated voltage)
Release time (Rated voltage)
Dielectric Strength
Ambient temperature
Humidity
Atmospheric pressure
Shock resistance
Vibration resistance
Install model
Weight
Coil Specifications (25℃)
Rated voltage V.DCCoil resistanceΩ(±10%)
Rated voltage V.ACCoil resistance Ω(±10%)
141
Protection
Motor C
ontrol &
yCDZ8 Miniature Rela
Matched relay socket
CDZ8PYF08AXXKH
Outline dimensions(mm) Mount dimensions Wiring diagram
CDZ8PYF11AXXKH
CDZ8PYF14AXXKH
2Z
3Z
4Z
Accessories
142
Motor C
ontrol &
Protection
yCDZ8 Miniature Rela
Overall Dimensions
■ CDZ8-4Z
■ CDZ8-2Z
■ CDZ8-3Z
Unit: mm
143
Protection
Motor C
ontrol &
Function
Standard: IEC 60947-5-1
JSZ3 Series Electronic Time Relay
JSZ3 Series eletroms time relay provideRated AC frequency 50Hz & controlling voltage 400V or below.
Order Information
Relay mode Rated working voltage Relay time Reference
Relay after power-on
A: 0.05-0.5s/5s/30s/3MB: 0.1-1s/10s/60s/6MC: 0.5-5s/50s/5M/30MD: 1-10s/100s/10M/60ME: 6s-60s/10M/60M/6hF: 0.2M-2M/20M/2h/12hG: 0.4M-4M/40M/4h/24h A: 0.05-0.5s/5s/30s/3MB: 0.1-1s/10s/60s/6MC: 0.5-5s/50s/5M/30MD: 1-10s/100s/10M/60ME: 6s-60s/10M/60M/6hF: 0.2M-2M/20M/2h/12hG: 0.4M-4M/40M/4h/24h A: 0.05-0.5s/5s/30s/3MB: 0.1-1s/10s/60s/6MC: 0.5-5s/50s/5M/30MD: 1-10s/100s/10M/60ME: 6s-60s/10M/60M/6hF: 0.2M-2M/20M/2h/12hG: 0.4M-4M/40M/4h/24h
120V
240V
400V
JSZ3AA120JSZ3AB120JSZ3AC120JSZ3AD120JSZ3AE120JSZ3AF120JSZ3AG120JSZ3AA240JSZ3AB240JSZ3AC240JSZ3AD240JSZ3AE240JSZ3AF240JSZ3AG240JSZ3AA400JSZ3AB400JSZ3AC400JSZ3AD400JSZ3AE400JSZ3AF400JSZ3AG400
Be used as time-control component in the automatic controlling cir-cuit, according to the scheduled time turn on or off the circuit.
Rated DC control power voltage 220V or below.
144
Motor C
ontrol &
Protection
Standard: IEC 60947-5-1
JSZ3 Series Electronic Time Relay
Relay mode Rated working voltage Relay time Reference
Relay after power-off
1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s5S: 0.5s-5s6S: 0.6s-6s10S: 1s-10s20S: 2s-20s30S: 3s-30s60S: 6s-60s100S: 10s-100s180S: 18s-180s4M: 0.4min-4min5M: 0.5min-5min6M: 0.6min-6min10M: 1min-10min20M: 2min-20min30M: 3min-30min1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s5S: 0.5s-5s6S: 0.6s-6s10S: 1s-10s20S: 2s-20s30S: 3s-30s60S: 6s-60s100S: 10s-100s180S: 18s-180s4M: 0.4min-4min5M: 0.5min-5min6M: 0.6min-6min10M: 1min-10min20M: 2min-20min30M: 3min-30min1S: 0.1-1s 2S: 0.2-2s 3S: 0.3s-3s5S: 0.5s-5s6S: 0.6s-6s10S: 1s-10s20S: 2s-20s30S: 3s-30s60S: 6s-60s100S: 10s-100s180S: 18s-180s4M: 0.4min-4min5M: 0.5min-5min6M: 0.6min-6min10M: 1min-10min20M: 2min-20min30M: 3min-30min
JSZ3F1S120JSZ3F2S120JSZ3F3S120JSZ3F5S120JSZ3F6S120JSZ3F10S120JSZ3F20S120JSZ3F30S120JSZ3F60S120JSZ3F100S120JSZ3F180S120JSZ3F4M120JSZ3F5M120JSZ3F6M120JSZ3F10M120JSZ3F20M120JSZ3F30M120JSZ3F1S240JSZ3F2S240JSZ3F3S240JSZ3F5S240JSZ3F6S240JSZ3F10S240JSZ3F20S240JSZ3F30S240JSZ3F60S240JSZ3F100S240JSZ3F180S240JSZ3F4M240JSZ3F5M240JSZ3F6M240JSZ3F10M240JSZ3F20M240JSZ3F30M240JSZ3F1S400JSZ3F2S400JSZ3F3S400JSZ3F5S400JSZ3F6S400JSZ3F10S400JSZ3F20S400JSZ3F30S400JSZ3F60S400JSZ3F100S400JSZ3F180S400JSZ3F4M400JSZ3F5M400JSZ3F6M400JSZ3F10M400JSZ3F20M400JSZ3F30M400
120V
240V
400V
Order Information
145
Protection
Motor C
ontrol &
Technical Data
Standard: IEC 60947-5-1
JSZ3 Series Electronic Time Relay
Overall Dimensions
Condition AC-15 DC-13 Repetitive errorRated themal currentMechanical life Electric lifePower lossWorking mode Reset modeContactor enduranceRelay time
Temp.Install mode
-5℃~+40℃Install mounted, Din rail mounted, Panel mounted
400V/1.95A; 240V/1.5A; 120V/3.0A 250V/0.27A; 125V/0.55A ≤5% 5A ≥1×106 times ≥1×105 times ≤3W A: Relay after power-on F:Relay after power-off A:Power-off reset F:External device reset A:5A (Resistive) F:1A(Resistive) JSZ3A: 0.05s-0.5s/5s/30s/3M,0.1s-1s/10s/60s/6M0.5s-5s/50s/5M/30M,1s-10s/100s/10M/60M6s-60s/10M/60M/6h,0.2M-2M/20M/2h/12h0.4M-4M/40M/4h/24h JSZ3F: 0.1s-1s,0.2s-2s,0.3s-3s,0.5s-5s,0.6s-6s,1s-10s,2s-20s,3s-30s,6s-60s,10s-100s,10s-120s,10s-180s,0.4M-4M,0.5M-5M,0.6M-6M,1M-10M,2M-20M,3M-30M
Unit: mm
ELECTRIC
146
Motor C
ontrol &
Protection
Function
Technical Data
Order Information
Overall Dimensions
XJ9 Phase Failure And Sequence Protection Relay
Rated AC frequency of 50Hz, rated control supply voltage AC 400V.Phase failure and phase sequence protector.
XJ9 phace failare and sequence proctection relay provide:
Standard: IEC 60947-5-1
Phase failuresequency protection
Function
380V400V
Voltage
XJ9380XJ9400
Reference
IEC 60947-5-1 400-480V(adjustable), Reaction time: 1.5-4S(adjustable)320-400V(adjustabe). Reaction time: 2-9S(adjustable)Reaction time ≤2S
1 NO,1NC5A ResistiveAC 400V≥1×106 times≥1×105 times≤1WAC400V×3
Standard Overvoltage protectionUndervoltage protectionPhase failure & phase Wrong protect timeContactor modeContactor endurancePower voltageMechanical lifetimeElectrical lifetimePower loss Contactor capacity
Unit: mm
XJ9
91Max
35.5 83Max
24Max
147
Managem
entP
ower E
nergy
Contents
Power Energy Management
Meter
LMK
72 Series Panel Meter
96 Series Panel Meter
Current Transformer
Digital Time Switch
Voltage Stabilizer
KG316T Digital Time Switch
KG316TD Digital Time Switch
KG816 Series Digital Time Switch
TND
SJW
SBW Three-phase Compensation AC Voltage Stabilizer
1~5
Series Current Transformer
DDS607 Single-phase Electronic Watt-hour Meter
DTS607 Three-phase Four-Wire Electronic Watt-hour Meter
DSS607 Three-phase Three-Wire Electronic Watt-hour Meter
Three-phase Full Automatic AC Voltage Stabilizer
Single-phase Full Automatic AC Voltage Stabilizer
148-150148
151-163152
154
157
165
166
167
160
162
164-167
168-174169
171
173
148
Pow
er Energy
Managem
ent
LMK Series Current TransformerStandard: IEC 60044-1
Class: 0.5Maximum Voltage: 0.66KV
LMK-0.66-20
LMK-0.66-30
LMK-0.66-40
LMK-0.66-50
LMK-0.66-60
LMK-0.66-80
LMK-0.66-100
LMK-0.66-120
30/5 50/5 75/5 100/5 100/5 150/5 200/5 100/5 200/5 250/5 300/5 250/5 300/5 400/5 500/5 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5
5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75
20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 35 35 35 35 35 35 35 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 6060 60 60 60 60 60 60 60 60 60
5 3 2 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
LMKP63020 LMKP65020 LMKP67520 LMKP610020 LMKP610020 LMKP615020 LMKP620020 LMKP610030 LMKP620030 LMKP625030 LMKP630030 LMKP625040 LMKP630040 LMKP640040 LMKP650040 LMKP630050 LMKP640050 LMKP650050 LMKP660050 LMKP675050 LMKP680050 LMKP6100050 LMKP650060 LMKP660060 LMKP675060 LMKP680060 LMKP6100060 LMKP6120060 LMKP6150060 LMKP660080 LMKP675080 LMKP680080 LMKP6100080 LMKP6120080 LMKP6150080 LMKP6200080 LMKP6250080 LMKP6600100 LMKP6750100 LMKP6800100 LMKP61000100 LMKP61200100 LMKP61500100 LMKP62000100 LMKP62500100 LMKP63000100 LMKP61500120 LMKP62000120 LMKP62500120 LMKP63000120 LMKP64000120 LMKP65000120
30×10 30×10 30×10 40×10 40×10 40×10 40×10 50×10 50×10 50×10 50×10 50×10 50×10 50×10 60×20 60×20 60×20 60×20 60×20 60×20 60×20 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30
LMK Series Current Transformer provide: Function
Order Information
Measuring and transforming the high current to low current.
Model Current ratio(A)
Rated Load(VA)
Bar (mm)
Number of Turnsthrough the core
ReferenceDiameter(mm)
149
Managem
entP
ower E
nergy
Class: 1Maximum Voltage: 0.66KV
LMK Series Current TransformerStandard: IEC 60044-1
Order Information
5 3 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1111
LMK-0.66-20
LMK-0.66-30
LMK-0.66-40
LMK-0.66-50
LMK-0.66-60
LMK-0.66-80
LMK-0.66-100
LMK-0.66-120
30/5 50/5 75/5 100/5 150/5 200/5 100/5 200/5 250/5 300/5 250/5 300/5 400/5 500/5 600/5 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 1200/5 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5
5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75
20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 35 35 35 35 35 35 35 35 45 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
LMKP6P13020 LMKP6P15020 LMKP6P17520 LMKP6P110020 LMKP6P115020 LMKP6P120020 LMKP6P110030 LMKP6P120030 LMKP6P125030 LMKP6P130030 LMKP6P125040 LMKP6P130040 LMKP6P140040 LMKP6P150040 LMKP6P160040 LMKP6P130050 LMKP6P140050 LMKP6P150050 LMKP6P160050 LMKP6P175050 LMKP6P180050 LMKP6P1100050 LMKP6P1120050 LMKP6P150060 LMKP6P160060 LMKP6P175060 LMKP6P180060 LMKP6P1100060 LMKP6P1120060 LMKP6P1150060 LMKP6P1200060 LMKP6P160080 LMKP6P175080 LMKP6P180080 LMKP6P1100080 LMKP6P1120080 LMKP6P1150080 LMKP6P1200080 LMKP6P1250080 LMKP6P1600100 LMKP6P1750100 LMKP6P1800100 LMKP6P11000100 LMKP6P11200100 LMKP6P11500100 LMKP6P12000100 LMKP6P12500100 LMKP6P13000100 LMKP6P11500120 LMKP6P12000120 LMKP6P12500120 LMKP6P13000120 LMKP6P14000120 LMKP6P15000120
30×10 30×10 30×10 40×10 40×10 40×10 40×10 40×1050×10 50×10 50×10 50×10 50×10 50×10 50×10 60×20 60×20 60×20 60×20 60×20 60×20 60×20 60×20 60×20 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 80×10 or 60×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 100×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30 120×10 or 80×30
Model Current ratio(A)
Rated Load(VA)
Bar (mm)
Number of Turnsthrough the core
ReferenceDiameter(mm)
150
Pow
er Energy
Managem
ent
Unit: mm
LMK Series Current Transformer
Technical Data
Overall Dimensions
LMK-0.66-20LMK-0.66-30LMK-0.66-40LMK-0.66-50LMK-0.66-60LMK-0.66-80LMK-0.66-100LMK-0.66-120
Model87799999126118136136
H
68607582102125170190
W
4237404040404041
D
Standard: IEC 60044-1
Primary current: 100A-5000A Secondary approval: 5A, 1A Maximum voltage: 0.66kV Class: 0.5, 1.0, 3.0 Short time thermal current: Ith=100Ih Rated security coefficient: FS<5
Standard: IEC 60044-1
151
Managem
entP
ower E
nergy
Meter Overview
MeterSingle-phase
Three-phase
DDS607
Specification1.5(6)A, 3(6)A2.5(10)A, 5(20)A5(30)A, 10(40)A15(60)A, 20(80)A30(100)A
Type: Single-phase
DTS607
Specification1.5(6)A, 3(6)A2.5(10)A, 5(20)A5(30)A, 10(40)A15(60)A, 20(80)A30(100)A
Type: Three-phase Four-wire
DSS607
Specification1.5(6)A, 3(6)A5(20)A, 10(40)A15(60)A. 20(80)A30(100)A
Type: Three-phase Three-wire
Panel Meter
teWatt-hour Me r
72 Series
Specification 72x72mm
96 Series
Specification 96x96mm
Type: Ammeter Voltmeter Frequency meter
Type: Ammeter Voltmeter Frequency meter
152
154 157
160 162
152
Pow
er Energy
Managem
ent
Order Informationn
Type A (Import chip)Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type A (Import chip) Type C (Domestic chip)Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) Type C (Domestic chip) LCD without 485 communicationsLCD without 485 communications LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD without 485 communications LCD with 485 communications LCD with 485 communications LCD with 485 communications LCD with 485 communications LCD with 485 communications and infrared communicationsLCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications LCD with 485 communications and infrared communications
1.5(6)A2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A 30(100)A1.5(6)A 2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A 30(100)A1.5(6)A 2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A1.5(6)A 5(20)A 10(40)A 15(60)A1.5(6)A 2.5(10)A 5(20)A 5(30)A 10(40)A 15(60)A 20(80)A
30(100)A
DDS607N16M4ADDS607N110M4A DDS607N120M4A DDS607N130M6A DDS607N140M4A DDS607N160M4A DDS607N180M4A DDS607N1100M3ADDS607N26M4C DDS607N210M4C DDS607N220M4C DDS607N230M6C DDS607N240M4C DDS607N260M4C DDS607N280M4C DDS607N2100M3CDDS607N16M4CD DDS607N110M4CD DDS607N120M4CD DDS607N130M6CD DDS607N140M4CD DDS607N160M4CD DDS607N180M4CDDDS607N16M4CD485 DDS607N120M4CD485 DDS607N140M4CD485 DDS607N160M4CD485DDS607N116M4CD485I DDS607N110M4CD485I DDS607N120M4CD485I DDS607N130M6CD485I DDS607N140M4CD485I DDS607N160M4CD485I DDS607N180M4CD485I DDS607N1100M3CD485I
Function Description Current specification Reference
Note: Users need special specifications can be customized
Function
DDS607 Single-phase Electronic Watt-hour MeterStandard:IEC 620531-21
DDS607 single-phase watt-hour meter provide:Measuring the active energy in the single-phase AC power network withfrequency of 50Hz or 60Hz.Measuring the active energy for enterprises, transformer substation or power substation. And be used as the automation meter in power transmission and distribution.
153
Managem
entP
ower E
nergy
DDS607 Single-phase Electronic Watt-hour MeterStandard:IEC 620531-21
Technical Data
Overall Dimensions
Single-phase Type A,C Mete Sr ingle-phase LCD Meter
Unit: mm
Standard
CertificateWorking voltage(V)
Power loss
Optional functions
230V
Voltage circuit ≤2W per10VA, Current circuit ≤4VA
LCD display, Infrared communication, 485 communication
IEC 620531-21
KEMA
-10℃~+45℃
-25℃~+55℃
0.9~1.1(Ref. voltage)
0.8~1.15(Ref. voltage)
<75%
Should be installed in the height of 1.8m vertically and the angularity≤1°
Normal working temp.
Limited working temp.
Normal working voltage
Limited working voltage
Relative humidity
Installation location
154
Pow
er Energy
Managem
ent
Function
Standard: IEC 62053-21
DTS607 Three-phase Four-wire Electronic Watt-hour Meter
DTS607 Three Phase four-wire watt-hour meter provide:Measuring the active energy in the three-phase four-wire AC power network atfrequency of 50Hz or 60Hz.Measure the active energy of enterprises, transformer substation or powerstations, and be used as automation meters of power transmission and distribution network.
Order Information
Voltage(V) Grade Current(A)
57.7/100
230/400
1 1.5(6) 3(6)1.5(6)3(6)5(20)10(40)15(60)20(80)30(100)
1
Reference
DTS607WY16M4DTS607WY16M2DTS607NV16M4DTS607NV16M2DTS607NV120M4DTS607NV120M5DTS607NV120M6DTS607NV120M7DTS607NV120M8
NOTE: “M” expresses the current multiple in the standard codes. Transformer function (H) is merely available for 1.5(6)A and 3(6)A.
155
Managem
entP
ower E
nergy
Technical Data
57.7/100V, 230/400VVoltage circuit≤2W per10VA, Current circuit≤4VALCD display, Infrared communication, 485 communication
Working voltagePower lossOptional functions
-10℃~+45℃-25℃~+55℃0.9~1.1(Ref. voltage)0.8~1.15(Ref. voltage)<75%Should be installed in the height of 1.8m vertically and the angularity≤1°.
Normal working temp.Ultimate working temp.Normal working voltageUltimate working voltageRelative humidityInstallation location
Standard: IEC 62053-21
DTS607 Three-phase Four-wire Electronic Watt-hour Meter
Wiring Diagram
■ Wiring diagram for 3 x 57.7/100V ≤3 x 3(6)A with voltage transformer
■ Wiring diagram for 3 x 230/400V ≤3 x 3(6)A with current transformer
156
Pow
er Energy
Managem
ent
Unit: mm
■
■
Wiring diagram for 3 x 230/400V ≥3 x 2.5(10)A direct
Wiring diagram for impulse testing
pulse pulse pulse pulse
Overall Dimensions
Wiring Diagram
Standard: IEC 62053-21
DTS607 Three-phase Four-wire Electronic Watt-hour Meter
157
Managem
entP
ower E
nergy
Order Information
Function
DSS607 Single-phase Electronic Watt-hour MeterStandard: IEC 62053-21
Voltage(V) Grade
100
400
1
Reference
DSS607Y16M4DSS607Y16M2DSS607V16M4DSS607V16M2DSS607V120M4DSS607V140M4DSS607V160M4DSS607V180M4DSS607V1100M3
1
Current(A)
1.5(6)3(6)1.5(6)3(6)5(20)10(40)15(60)20(80)30(100)
NOTE: “M” expresses the current multiple in the standard codes. Transformer function (H) is merely available for 1.5(6)A and 3(6)A.
DSS607 Single-phase electronic watt-hour meter provides:Measuring the active energy in the three-phase three-wire AC power network at frequency of 50Hz or 60Hz.Measure the active energy of enterprises, transformer substation or power sta-tions, and be used as automation meters of power transmission and distribution network
158
Pow
er Energy
Managem
ent
■ Wiring diagram for 3 x 400V ≤3 x 3(6)A with current transformer
■ Wiring diagram for 3 x 100V ≤3 x 3(6)A with voltage transformer
Wiring Diagram
Standard IEC 62053-21
℃~
℃~
℃
℃
~
~
<75%
Technical Data
DSS607 Single-phase Electronic Watt-hour MeterStandard: IEC 62053-21
159
Managem
entP
ower E
nergy
DSS607 Single-phase Electronic Watt-hour MeterStandard: IEC 62053-21
■ Wiring diagram for 3 x 400V ≥3 x 2.5(10)A direct
■ Wiring diagram for impulse testing
Overall DimensionsUnit: mm
pulse pulse pulse pulse
Wiring Diagram
160
Pow
er Energy
Managem
ent
Order Information
Standard: IEC 60051
72 Series Panel Meter
30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A 150/5A 160/5A 200/5A 250/5A 300/5A 400/5A 600/5A 800/5A 1000/5A 1600/5A 5000/5A 10000/5A 5A 15A 20A 25A 30A 40A 50A 60A 80A 100A 5A300V 500V 600V 500V45-55HZ (200V)
72×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.5 72×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.5
72×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.5 72×72×67.572×72×67.572×72×67.5 72×72×67.5
72TA30 72TA40 72TA50 72TA60 72TA75 72TA80 72TA100 72TA150 72TA160 72TA200 72TA250 72TA300 72TA400 72TA600 72TA800 72TA1000 72TA1600 72TA5000 72TA1000072TA5A
72TA15A 72TA20A 72TA25A 72TA30A 72TA40A 72TA50A 72TA60A 72TA80A 72TA100A 72CA5A 72TV300V 72TV500V 72TV600V 72CV5500V72THZ01200V
AC Type External connection transformer 2 times of current overload
AC Type Direct connection AC TypeDirect connection 2 times of current overload
DC TypeAC Type
DC Type AC Type
Type Accuracy Specification Note Shape(mm) Reference rating
1.5
2.5
1.51.5
1.0
Ammeter
Voltmeter
Frequency meter
Function 72 series panel meter provide: 72T applies to measure the current, voltage or frequency in the AC circuit.
72C applies to measure the current or voltage in the DC circuit.Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and other electric-control facilities in the AC transmission circuit system
161
Managem
entP
ower E
nergy
Standard: IEC 60051
72 Series Panel Meter
Overall Dimensions
Technical Data
Dielectric strength test
Impact te
::
IEC 60051Standard
Frequency 50Hz/60Hz
s Mt ax acceleration 147m/s2
4s90-25℃~+40(25%~80%)RHNo mildew, insects, salt mist, dew in the air,few sands and dusts are permitted.Shall be installed Verticallyv
。
Response timeAngular Deflection
TempHumidityEnvironment
Installation:
.
Voltage 2000V, duration 1 minute
30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A 150/5A 160/5A 200/5A 250/5A 300/5A 400/5A 600/5A 800/5A 1000/5A 1600/5A 5000/5A 10000/5A 5A 15A 20A 25A 30A 40A 50A 60A 80A 100A 5A300V 500V 600V 500V45-55HZ (200V)
72×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.5 72×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.5
72×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.572×72×67.572×72×67.572×72×67.5 72×72×67.5 72×72×67.572×72×67.572×72×67.5 72×72×67.5
72TA30 72TA40 72TA50 72TA60 72TA75 72TA80 72TA100 72TA150 72TA160 72TA200 72TA250 72TA300 72TA400 72TA600 72TA800 72TA1000 72TA1600 72TA5000 72TA1000072TA5A
72TA15A 72TA20A 72TA25A 72TA30A 72TA40A 72TA50A 72TA60A 72TA80A 72TA100A 72CA5A 72TV300V 72TV500V 72TV600V 72CV5500V72THZ01200V
AC Type External connection transformer 2 times of current overload
AC Type Direct connection AC TypeDirect connection 2 times of current overload
DC TypeAC Type
DC Type AC Type
Type Accuracy Specification Note Shape(mm) Reference rating
1.5
2.5
1.51.5
1.0
Ammeter
Voltmeter
Frequency meter
162
Pow
er Energy
Managem
ent
96 Series Panel MeterStandard: IEC 60051
96×96×67.596×96×67.596×96×67.5 96×96×67.596×96×67.596×96×67.5 96×96×67.596×96×67.596×96×67.5 96×96×67.596×96×67.596×96×67.5 96×96×67.596×96×67.596×96×67.5 96×96×67.596×96×67.596×96×67.596×96×67.596×96×67.5
96×96×67.596×96×67.596×96×67.596×96×67.596×96×67.596×96×67.596×96×67.596×96×67.596×96×67.596×96×67.596×96×67.5 96×96×67.596×96×67.596×96×67.596×96×67.5
96TA30 96TA40 96TA50 96TA60 96TA75 96TA80 96TA100 96TA150 96TA160 96TA200 96TA250 96TA300 96TA400 96TA600 96TA800 96TA1000 96TA1600 96TA5000 96TA10000 96TA5A 96TA15A 96TA20A 96TA25A 96TA30A 96TA40A 96TA50A 96TA60A 96TA80A 96TA100A 96CA5A 96TV300V 96TV500V 96TV600V 96CV50096THZ01200V
30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A 150/5A 160/5A 200/5A 250/5A 300/5A 400/5A 600/5A 800/5A 1000/5A 1600/5A 5000/5A 10000/5A 5A 15A 20A 25A 30A 40A 50A 60A 80A 100A 5A300V 500V 600V 500V45-55HZ (200V)
AC Type External connection transformer
AC Type Direct connection AC TypeDirect connection
DC TypeAC Type
DC Type AC Type
Ammeter
Voltmeter
Frequency meter
1.5
2.5
1.51.5
1.0
Order Information
Type Accuracy Specification Note Shape(mm) Reference rating
Function 96 series panel meter provide: 96T applies to measure the current, voltage or frequency in the AC circuit.
96C applies to measure the current or voltage in the DC circuit.Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and other electric-control facilities in the AC transmission circuit system
163
Managem
entP
ower E
nergy
96 Series Panel MeterStandard: IEC 60051
Technical Data
Overall Dimensions
Dielectric strength test
:
Installation:
Frequency 50Hz/60HzStandard IEC 60051
Impact testResponse timeAngular DeflectionTempHumidity:Environment
-25℃~+40(25%~80%)RHNo mildew, insects, salt mist, dew in the air,few sands and dusts are permitted.Shall be installed Verticallyv
Max acceleration 147m/s≤ 4s90。
.
Voltage 2000V, duration 1 minute
2
164
Pow
er Energy
Managem
ent
Time Switch Overview
KG316T
Max.switch times per day:10-on-10-off, 8-on-8-off Reset:Power-off reset
KG816B
Max.switch times per day:8-on-8-off Reset:key-button reset
KG316TD
Max.switch times per day:16-on-16-off Reset:key-button reset
KG816A
Max.switch times per day:16-on-16-off Reset:key-button reset
165
166
167
167
165
Managem
entP
ower E
nergy
KG316T Series Digital Time Switch provide:Rated AC frequency of 50Hz, rated AC control voltage 400V or below.Be used as time control components in automatic control circuit, according to thescheduled time to turn-on or off the circuits.
Function
KG316T Series Digital Time Switch
Standard: IEC 60947-5-1
Technical Data
Order Information
Output loops Reference
10-on-10-off (Single output)
8-on-8-off (Double output)
AC:230VAC:400V AC:230VAC:400V
KG316T230KG316T400KG316T2230KG316T2400
Wiring Diagram
INPUT OUTPUT
SO
UR
CE
SO
UR
CE
LOA
D
N
LOAD 1 LOAD 2
IN L1 OUT L1 OUT L2
Single output Double output
Overall DimensionsUnit: mm
Control time
Using modeControl powerRated control voltage
Rated thermal cur.
Mechanical lifeElectrical lifePower lossTemp.
Setting Value range from 1min to168hOperation by daily or weeklyAC-15: 240V/3A 400V/1.9A
6kW
10A
≥1×106 times≥1×105 times≤3W-5℃~+40℃
Standard IEC 60947-5-1
Accuracy y
Display modet
BatteryTime-set Mode
Install Mode
Digital LED displayDigital Keyswitch settingtInner alkaline batteryInstall mounted, Din rail mounted
Display modet
BatteryTime-set Mode
Install Mode
Rated control voltage
230/400V AC
2
~
166
Pow
er Energy
Managem
ent
Function KG316TD Series Digital Time Switch provide:Rated AC frequency of 50Hz, rated control supply voltage AC 400V or below.Any circuit equipments that need to be turned-on-or-off timely.
KG316TD Series Digital Time Switch
Standard: IEC 60947-5-1
Order Information
Technical Data
y400V/1.9A
r.
Setting Value range from 1min to168hOperation by daily or weeklAC-15: 240V/3A
6kW
10A
≥1×106 times≥1×105 times≤3W-5℃~+40℃
IEC 60947-5-1
Digital LED displayDigital Keyswitch settingt
Install mounted, Din rail mounted Inner rechangeable battery
Control time
Using modeControl powerRated control voltage
Rated thermal cu
Mechanical lifeElectrical lifePower lossTemp.
Standard
Accuracy
Display modet
BatteryTime-set Mode
Install Mode
Display modet
BatteryTime-set Mode
Install Mode
Managem
entP
ower E
nergy
Wiring Diagram
Overall DimensionsUnit: mm
KG316TD230KG316TD400
Output loops
16-on-16-off
Rated control voltage
AC:230VAC:400V
Reference
230/400V AC
167
Managem
entP
ower E
nergy
Unit: mm
KG816A
KG816B
Order Information
Technical Data
KG816 Series Digital Time Switch provide:Rated AC frequency of 50Hz, rated AC control voltage 230V or below.Be used as time control components in automatic control circuit, according to the scheduled time to turn-on or off the circuits.
KG816 Series Digital Time SwitchStandard:IEC 60947-5-1
Function
Cover Output loops Rated control voltage Reference
Non-transparent cover 16-on-16-off AC:230V KG816A230
Transparent cover 8-on-8-off AC:230V KG816B230
Standard IEC 60947-5-1Control time Setting value range from 1min to 168 hrs
Using mode AC-15: 240V/3A; 400V/1.9A
Countrol power ≤6kW
Rated control voltage 230VAC
Rated thermal cur. 10A
Accuracy ≤2s/day
Mechanical life ≥1X10
Electrical life ≥1X10
6
5
Power loss ≤4.5W
-5℃ ℃
Display mode Digital LED display
Time-set Mode Digital Keyswitch setting
Battery Inner rechangable battery
Install Mode Din rail mounted
Operate by daily or weekly
Overall Dimensions
Temp. ~+40
66
8787
36
45.5
168
Pow
er Energy
Managem
ent
Voltage Stabilizer Overview
TND
Type: Single-phase Specification: 0.5kVA, 1kVA 1.5kVA, 2kVA, 3kVA, 5kVA, 7kVA, 10kVA, 15kVA, 20kVA, 30kVA
SJW
Type: Three-phase Specification: 1.5kVA, 3kVA 4.5kVA, 6kVA, 9kVA, 15kVA, 20kVA, 30kVA, 45kVA, 60kVA
SBW
Type: Three-phase Compensation Specification: 10kVA, 15kVA 30kVA, 50kVA, 100kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA, 600kVA, 800kVA
Single-phase
Three-phase
169
171
173
169
Managem
entP
ower E
nergy
TND Single-phase Full Automatic AC Voltage StabilizerStandard: EN 61000-6-2 EN 61000-6-4 EN 61558-1
This product is constructed by connecting three stabilizers with Y-connection
Wide input voltage range, high efficiency, over-load protection, short adjusting time,high regulation accuracy, same input and output voltage waveform, small volume,
less weight.It's available in the electric equipments and facilities in housing, school, shop, office
and precision instrument for scientific experiment.
TND single-phase AC voltage stabilizer provide:Function
Europe plug British plug
TNDP5HE230TND1HE230TND1P5HE230-----
TNDP5HB230TND1HB230TND1P5HB230-----
---TND2H230TND3H230TND5H230
TND10H230
Desktop
Terminal connect
220V 0.5K1K1.5K2K3K5K7K10K
TNDP5HE220TND1HE220TND1P5HE220-----
TNDP5HB220TND1HB220TND1P5HB220-----
---TND2H220TND3H220TND5H220TND7H220TND10H220
Cabinet 220V 10K15K20K30K
10K15K20K30K
----
----
TND10GH220TND15GH220TND20GH220TND30GH220
Desktop 230V
230V
0.5K1K1.5K2K3K5K7K10K
Cabinet--
--
----
TND10GH230TND15GH230TND20GH230TND30GH230
Order Information
TND7H230
ReferenceShape Output voltage
Power rating
170
Pow
er Energy
Managem
ent
Technical Data
Overall DimensionsUnit: mm
Withstand voltage 1500V/1min
TND-0.5 TND-1 TND-1.5 TND-2 TND-3 TND-5 TND-7 TND-10 TND-10 TND-15 TND-20 TND30
Desktop
Cabinet type
Product shape Model Wide×Length×Hight
Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1
TND0.5kVA~5kVA TND7kVA~30kVA 220±4%,110±4% 220±4%184V±4V(set up according to the customers request)246V±4Vsingle-phase 160V~240V >90% <1s(when input voltage change 10%) 50/60Hz -50℃~40℃ below 90% 2(500VA), 4(1000VA), 6(1500VA), 8(2000VA)12(3000VA), 20(5000VA), 25(7000VA), 40(10KVA)85(15KVA), 73(20KVA), 109(30KVA)
Certification: CE
W 190 160 135 205 190 155205 190 155240 270 200225 305 235225 310 290240 387 360240 387 360310 340 535340 360 640340 380 780425 390 845
L H
Type Output voltage
Phase Input voltage range Efficiency Voltage regulation speed FrequencyEnviroment temperature,relative temperature Rated maximum output current(A)
Voltage regulation accuracyUndervoltage protectionOvervoltage protection
TND Single-phase Full Automatic AC Voltage Stabilizer
Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1
171
Managem
entP
ower E
nergy
SJW Three-phase Full Automatic AC Voltage Stabilizer
6kVA9kVA15 kVA20 kVA30 kVA45 kVA
Deskto 1p .5 kVA3kVA4.5 kVA
SJW1P5SJW3SJW4P5
Cabinet SJW6GSJW9GSJW15GSJW20GSJW30GSJW45G
SJW three-phase AC voltage stabilizer provide:
This product is constructed by connecting three stabilizers with Y-connectionWide input voltage range, high efficiency, over-load protection, short adjusting
time, high regulation accuracy, same input and output voltage waveform, smallvolume, less weight.
It's available in the electric equipments and facilities in housing, factory, shool,shop, office and precision instrument for scientific experiment.
Function
Order Information
Overall Dimensions
Technical Data
Type
Output voltage
Input voltage rangeEfficiencyVoltage regulation speedFrequencyWaveform distortion:Withstand voltageTemperature riseEnvironment temp.
Voltage regulation accuracyLow-voltage protection Over-voltage protection
SJW 1.5KVA~60KVA380V ±4%340V±7V(adjustable)420V ±7V280~415V90%<1s(voltage fluctuation≥10%) 50/60HzNo additional distortion1500V/1min<+60℃-5℃~+40℃
ReferenceShape Power rating
172
Pow
er Energy
Managem
ent
■ Cabinet
ELECTRIC
PHASE C
PHASE B
PHASE A
PROTECT
OUTPUT VOLTAGE
VOLTAGE TEST
SJW9 HIGH ACCURACY FULL-AUTOMATIC AC VOLTAGE STABILIZER
WORKING
WORKING
WORKING
Wide x Length x HightShape
W L H
485485485278320350425440550600
315315315322325350390415450495
16516516566575085584587511701300
Model
Desktop
Cabinet
SJW-1P5 SJW-3 SJW-4.5 SJW-6 SJW-9 SJW-15 SJW-20 SJW-30 SJW-45 SJW-60
Overall Dimensions
SJW Three-phase Full Automatic AC Voltage Stabilizer
173
Managem
entP
ower E
nergy
Function
Type Output voltage
Input voltage rangeEfficiencyVoltage regulation speedFrequencyWaveform distortionInsulation resistanceWithstand voltageTemperature riseEnvironment temp.
Voltage regulation accuracyLow-voltage protection Over-voltage protection
SBW 10KVA~1600KVA380V ±3%340V ±7V425V ±7V304~456≥98%<1s(voltage fluctuation≥10%) 50/60Hz≤1%≥2MΩ
2000V/1min<+60℃-5℃~+40℃
This product is designed and developed with the international advanced compensation technology. It can keep the output voltage in steady state automatically when the network voltage fluctuated or the load current varied. It's provided with over-voltage, over-current, phase sequence protection function.
SBW three-phase compensation AC voltage stabilizer provide:
SBW Three-phase Compensation AC Voltage Stabilizer
10k15k30k50k100k150k200k250k300k400k500k600k800k
Power rating Reference
VAVAVAVAVAVAVAVAVAVAVAVAVA
SBW10SBW15SBW30SBW50SBW100SBW150SBW200SBW250SBW300SBW400SBW500SBW600SBW800
Order Information
Technical Data
V
174
Pow
er Energy
Managem
ent
Overall Dimensions
Unit: mm
Wide x Length x HightModel
W L H
SBW-10SBW-20SBW-50SBW-100SBW-200SBW-500SBW-800SBW-1000SBW-1600
75075080085010501400135010501300
580580570645750110011007501100
SBW Three-phase Compensation AC Voltage Stabilizer
117011701300146018502100220022002200
175
Com
ponentsIndustrial C
ontrol
Contents
Industrial Control Components
AccessoriesRT16 Fuse
RT18 Fuse
CCF Series Cable Connector
Control SignalLD11 Indicator Light
LAY5
LAY7
LAY8
CDPM Moving Industrial Plugs
CDP Fixed Industrial Plugs
CDSM Moving Industrial Sockets
CDSF Fixed Industrial Sockets
CDPS Multi-function Plugs and Sockets
TB Series Copper Terminal Blocks
DINR Din-rail
Pushbutton
Pushbutton
Pushbutton
Switches
Switches
Switches
175-202177
181
191
197
203
206
209
211
212
213
214
215
221
217
203-221
176
Industrial Control
Com
ponents
Indicator Light
LD11
IP degree:IP65
SpecificationAC/DC: 6V 12V 24V 36V 48V 110V 230VAC: 230V 400V
Control Signal Overview
Pushbutton Switches
LAY8IP degree:IP55
SpecificationAC-15: 660V/1.5A
400V/2.5A 230V/4.5A
DC-13: 440V/0.2A
230V/0.4A 110V/0.8A
LAY7IP degree:IP55
SpecificationAC-15: 660V/1.1A
400V/2.0A 230V/3.3A
DC-13: 440V/0.25A
230V/0.5A 110V/1A
LAY5IP degree:IP55
SpecificationAC-15: 380V/2A 230V/3.3ADC-13: 230V/0.5A 110V/1.1A
177
181 191
197
177
Com
ponentsIndustrial C
ontrol
Function LD11 Series of indicator light provide: Pilot signal, anticipating signals Emergency signals and other instructions incidents signal use
Standard: IEC 60947-5
LD11 Indicator Light
Order Information
Overall Dimensions Unit:mmTypeStep-downType ReferenceRated voltageButton colourInstallation
dimension
A: Full coverhead & longterminal
22:¢22
AC.DC 6V
AC.DC 12V
AC.DC 24V
AC.DC 110V
AC.DC 230V
AC 230V
LD1122A21T7LD1122A21T3LD1122A21T4LD1122A21T5LD1122A21T8LD1122A21J7LD1122A21J3LD1122A21J4LD1122A21J5LD1122A21J8LD1122A21B7LD1122A21B3LD1122A21B4LD1122A21B5LD1122A21B8LD1122A21F7LD1122A21F3LD1122A21F4LD1122A21F5LD1122A21F8LD1122A21M7LD1122A21M3LD1122A21M4LD1122A21M5LD1122A21M8LD1122A41M7LD1122A41M3LD1122A41M4LD1122A41M5LD1122A41M8
2: Resistance type 4: Capacitancetype
AC230 400≤20
AC/DC6 12 24 36 48 110 230≤5030000≥402500V AC 1minIP65
Technical Data
Rated voltage(V)
Rated current(mA)Working life(H)Brightness of light(cd/m2)Power frequency withstand voltageDegree of protection
178
Industrial Control
Com
ponents
Order Information
Overall Dimensions Unit:mmTypeStep-downType ReferenceRated voltageButton colourInstallation
dimensionAC 400V
AC.DC 6V
AC.DC 12V
AC.DC 24V
LD1122A41Q7LD1122A41Q3LD1122A41Q4LD1122A41Q5LD1122A41Q8LD1122B21T7LD1122B21T3LD1122B21T4LD1122B21T5LD1122B21T8LD1122B21J7LD1122B21J3LD1122B21J4LD1122B21J5LD1122B21J8LD1122B21B7LD1122B21B3LD1122B21B4
AC.DC 110V
AC.DC 230V
AC 230V
AC 400V
LD1122B21B5LD1122B21B8LD1122B21F7LD1122B21F3LD1122B21F4LD1122B21F5LD1122B21F8LD1122B21M7LD1122B21M3LD1122B21M4LD1122B21M5LD1122B21M8LD1122B41M7LD1122B41M3LD1122B41M4LD1122B41M5LD1122B41M8LD1122B41Q7LD1122B41Q3LD1122B41Q4LD1122B41Q5LD1122B41Q8
B: Half cover head&long terminal
22:¢22 2: Resistance type 4: Capacitancetype
Standard: IEC 60947-5
LD11 Indicator Light
179
Com
ponentsIndustrial C
ontrol
Order Information
Overall Dimensions Unit:mmTypeStep-downType ReferenceRated voltageButton colourInstallation
dimension
C: Full coverhead & shortterminal
22:¢22 2: Resistance type 4: Capacitancetype
AC.DC 6V
AC.DC 12V
AC.DC 24V
AC 230V
AC 400V
LD1122C21T7LD1122C21T3LD1122C21T4LD1122C21T5LD1122C21T8LD1122C21J7LD1122C21J3LD1122C21J4LD1122C21J5LD1122C21J8LD1122C21B7LD1122C21B3LD1122C21B4LD1122C21B5LD1122C21B8LD1122C41M7LD1122C41M3LD1122C41M4LD1122C41M5LD1122C41M8LD1122C41Q7LD1122C41Q3LD1122C41Q4LD1122C41Q5LD1122C41Q8
Standard: IEC 60947-5
LD11 Indicator Light
180
Industrial Control
Com
ponents
AC.DC 6V
AC.DC 12V
AC.DC 24V
AC 230V
AC 400V
LD1122D21T7LD1122D21T3LD1122D21T4LD1122D21T5LD1122D21T8LD1122D21J7LD1122D21J3LD1122D21J4LD1122D21J5LD1122D21J8LD1122D21B7LD1122D21B3LD1122D21B4LD1122D21B5LD1122D21B8LD1122D41M7LD1122D41M3LD1122D41M4LD1122D41M5LD1122D41M8LD1122D41Q7LD1122D41Q3LD1122D41Q4LD1122D41Q5LD1122D41Q8
Order Information
Overall Dimensions Unit:mmTypeStep-downType ReferenceRated voltageButton colourInstallation
dimension
22:¢22 2: Resistance type 4: Capacitancetype
D: Half cover head&short terminal
Standard: IEC 60947-5
LD11 Indicator Light
181
Com
ponentsIndustrial C
ontrol
Function LAY5 series of pushbutton switches provide:
Control and indicate the status of the circuit
Technical Data
Working Condition
Temperature
Ralative humidity
Above sea level
Pollution grade
-5 ~+40
50%(40 ) 90%(20 )
2000m3
≤
≤
6V 12 24 110 230 380
2303.3
1101.1
3802
2300.5
AC-15
DC-13
LED
Usage mode Rated valve(Ue)(Ie)
VA
Rated voltageRated current
(Ue)(Ie)
VA
Rated voltageRated current
30 10
AC6( ) DC3( )
6IP55
IlluminatedSelective-type, Key-tpyeEmergency stop,1
Flush type
Selective-type, Key-tpyeEmergency stop,1Flush type Illuminated
(Ith) A
Mechanical endurance
Electric endurance
105
105
Rated thermal current
Protect degree
Power supplier voltage
Neon lampFilament lamp
Illuminated pushbutton
,
LAY5 Pushbutton SwitchesStandard: IEC 60947-5
182
Industrial Control
Com
ponents
LAY5 Pushbutton Switches
Order Information
B
E
A
A
LAY5BA15LAY5BA25LAY5BA31LAY5BA42LAY5BA55LAY5BA65
LAY5EA15LAY5EA25LAY5EA31LAY5EA42LAY5EA55LAY5EA65
LAY5
123456
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
Flush Button
Name Material Type Color NO + NC Reference
Unit: MM
Dimension
Metal
Plastic
Momentary
Momentary
WhiteBlack
GreenRedYellowBlue
123456
WhiteBlack
GreenRedYellowBlue
B D LAY5BD21
LAY5BD33
LAY5BD45LAY5BD53
LAY5BD252:2 C R
3:3 L C R
4:2 C R
5:3 L C R
LAY5
Name Material Type NO + NCReference
Unit: MM
Dimension
p
p
p
p
Metal
Selective Button Switch
Selective
Operation
button withshort handle
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
Standard: IEC 60947-5
183
Com
ponentsIndustrial C
ontrol
LAY5 Pushbutton Switches
Order Information
E
B
E
D
J
J
LAY5ED21
LAY5ED33LAY5ED45LAY5ED55
LAY5ED25
LAY5BJ21
LAY5BJ33LAY5BJ45
LAY5BJ55
LAY5BJ25
LAY5EJ21
LAY5EJ33LAY5EJ45LAY5EJ55
LAY5EJ25
2:2
3:3
4:2 C R
5:3 L C R
2:2 C R
3:3 L C R
4:2 C R
5:3 L C R
2:2 C R
3:3 L C R
4:2 C R
5:3 L C R
LAY5
C R
L C R
Name Material Type NO + NCReference
Unit: MM
Dimension
Selective SwitchesOperation
Plastic Selectiveswitch withshort handle
p
p
p
p
Metal
Plastic
Selectiveswitch withshort handle
Selectiveswitch withshort handle
p
p
p
p
p
p
p
p
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
Standard: IEC 60947-5
184
Industrial Control
Com
ponents
LAY5 Pushbutton Switches
Order Information
B G LAY5BG21
LAY5BG33LAY5BG45LAY5BG55
LAY5BG25
LAY5EG21
LAY5EG33LAY5EG45LAY5EG55
LAY5EG25
2:2 C R
3:3 L C R
4:2 C R
5:3 L C R
2:2 C R
3:3 L C R
4:2 C R
5:3 L C R
LAY5
B C: 40 LAY5BC31LAY5BC42LAY5BC35LAY5BC45
34
LAY5
Key-operated Selective SwitchesName Material Type NO + NC
Reference
Unit: MM
DimensionOperation
Name Material Type NO + NCReference
Unit: MM
Dimension
Metal Key-operatedselectiveswitches
p
p
p
p
reset
reset
E GPlastic Key-operatedselectiveswitches
p
p
p
p
reset
reset
Color
Metal
Mushroom Button
Mushroom GreenRed
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
Standard: IEC 60947-5
185
Com
ponentsIndustrial C
ontrol
B
E
E
R: 60
C: 40
R: 60
LAY5BR31LAY5BR42LAY5BR35LAY5BR45
LAY5EC31LAY5EC42LAY5EC35LAY5EC45
LAY5ER31LAY5ER42LAY5ER35LAY5ER45
34
34
34
LAY5Name Material Type NO + NC
Reference
Unit: MM
DimensionColor
Mushroom Button
Metal Mushroom GreenRed
Plastic Mushroom GreenRed
Plastic Mushroom GreenRed
Order Information
LAY5 Pushbutton Switches
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
Standard: IEC 60947-5
186
Industrial Control
Com
ponents
Order Information
B
B
B
S:
S:
S:
LAY5
4: 30
5: 40
6: 60
3
4
3
4
34
LAY5BS431LAY5BS442LAY5BS435LAY5BS445
LAY5BS531LAY5BS542LAY5BS535LAY5BS545
LAY5BS631LAY5BS642LAY5BS635LAY5BS645
Name Material Type NO + NCReference
Unit: MM
DimensionColor
Emergency Stop Button
Head
Metal Emergency GreenRed
Metal Emergency GreenRed
Metal Emergency Green
Red
LAY5 Pushbutton Switches
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
Standard: IEC 60947-5
187
Com
ponentsIndustrial C
ontrol
LAY5ES431LAY5ES442LAY5ES435LAY5ES445
LAY5ES531LAY5ES542LAY5ES535LAY5ES545
LAY5ES631LAY5ES642LAY5ES635LAY5ES645
E
E
E
S:
S:
S:
LAY5
4: 30
5: 40
6: 60
34
3
4
34
Name Material Type NO + NCReference
Unit: MM
DimensionColor
Emergency Stop Button
Head
Plastic Emergency GreenRed
Plastic Emergency Green
Red
Plastic Emergency GreenRed
Order Information
LAY5 Pushbutton Switches
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
Standard: IEC 60947-5
188
Industrial Control
Com
ponents
Order Information
B L8:
L8:
LAY5BL8325
LAY5BL8425
2:
LAY5
3:
4:
5: 1NO+1NC
5: 1NO+1NC
Two-head ButtonName Material Type NO + NC
Reference
Unit: MM
DimensionNo.of headHead
Metal Two-head Flush button 2
B Metal Two-head One high, 2: 2one low
LAY5 Pushbutton SwitchesStandard: IEC 60947-5
189
Com
ponentsIndustrial C
ontrol
LAY5 Pushbutton Switches
LAY5BW31*5LAY5BW33*1LAY5BW34*2LAY5BW35*5LAY5BW36*5LAY5BW37*5LAY5BW38*5
LAY5BW84*5
LAY5EW31*5LAY5EW33*1LAY5EW34*2LAY5EW35*5LAY5EW36*5LAY5EW37*5LAY5EW38*5
LAY5EW84*5
LAY5
T:6VB:24VF:110VN:230VQ:380V
T:6VB:24VF:110VN:230VQ:380V
T:6VB:24VF:110VN:230VQ:380V
T:6VB:24VF:110VN:230VQ:380V
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
5: 1NO+1NC
1: 1NO2: 1NC3: 2NO4: 2NC5: 1NO+1NC
5: 1NO+1NC
*
Illuminated Pushbutton Switches
ReferenceName Material Type NO + NCColor Voltage Light
B Metal W3 Flush
B Metal
e
E Plastic W3 Flush
E Plastic
1345678
WhiteGreen
RedYellow
BluePure whitePure blue
1345678
WhiteGreen
RedYellow
Blue
Pure bluPure white
4 One highone low
4 One highone low
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380VThe pure white and pure blue are only available for LED lamp.
Order Information
*
*******
*
*******
*NL
Neon
LEDBlank: Filament
NL
Neon
LED
Blank:
Filament
W8:Two head
W8:Two head
NL
Neon
LED
Blank:
Filament
NL
Neon
LED
Blank:
Filament
Standard: IEC 60947-5
190
Industrial Control
Com
ponents
Order Information
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380VThe pure white and pure blue are only available for LED lamp.
101: 1NO102: 1NC103: 2NO104: 2NC105: 1N0+1NC
LAY5BE101LAY5BE102LAY5BE103LAY5BE104LAY5BE105
LAY5
BE
B V:
LAY5
T:6VB:24VF:110VN:230VQ:380V
LAY5BV*1LAY5BV*3LAY5BV*4LAY5BV*5LAY5BV*6LAY5BV*7LAY5BV*8
*
Indication Lamp
Reference
Unit: MM
DimensionName Material Type ColorVoltage Light
Metal Indication 1345678
WhiteGreen
RedYellow
BluePure whitePure blue
Auxiliary contact
NL
Neon
LED
Reference DimensionName Type Contact
Base
*
*******
Blank:
Filament
LAY5 Pushbutton SwitchesStandard: IEC 60947-5
191
Com
ponentsIndustrial C
ontrol
Function LAY7 series of pushbutton switches provide: Control and indicate the status of the circuit
2303.31101
6601.14400.25
AC-15
DC-13
38022300.5
/hm
Vh
LED(Ue)
(Ue)(Ie)
(Ue)(Ie)
VA
VA
Usage mode Rated valveRated voltageRated current
Rated voltageRated current
Mechanical endurance 105
Electric endurance 105
ARated thermal current
Protect degree
Operation frequency T
Contact resistance
Illuminated pushbutton
Power supplier voltage Neon lampFilament lampWorking voltageLifetime
IP55
101200
50
30 10 IlluminatedSelective-type, Key-tpyeEmergency stop,0.5
Flush type
6 1 IlluminatedSelective-type, Key-tpyeEmergency stop,0.5
Flush type
Technical Data
lth
LAY7 Pushbutton Switches
6, 12, 241000≥
110, 220, 3802000≥
6, 12, 243000≥
≤
,
,
,
,
,
-5 ~+40
50%(40 ) 90%(20 )
2000m3
Temperature
Ralative humidity
Above sea level
Pollution grade
Working Condition
≤
≤
Standard: IEC 60947-5
192
Industrial Control
Com
ponents
Order Information
BN
BNZS
GN
GNZS
LAY711BN12LAY711BN22LAY711BN32LAY711BN42LAY711BN52LAY711BN62
LAY711BNZS32LAY711BNZS42
LAY711GN32LAY711GN42
LAY711GNZS32LAY711GNZS42
LAY7
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
123456
34
34
34
2 223 254 30
2 223 254 30
2 223 254 30
2 223 254 30
Flush Button
Name NO + NC Type Color Installation
Momentary WhiteBlackGreenRedYellowBlue
GreenRed
GreenRed
GreenRed
Reference
Unit: MM
Dimension
Maintained
Momentary
Maintained
LAY7 Pushbutton SwitchesStandard: IEC 60947-5
193
Com
ponentsIndustrial C
ontrol
LAY711JN32LAY711JN42
LAY7
2 223 254 30
LAY7
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
234
234
2 223 254 30
2 223 254 30
20:2 C R
21:2 C R
30:3 L C R
31:3 L C R
33:3 L C R
20:2 C R
21:2 C R
30:3 L C R
31:3 L C R
33:3 L C R
LAY711X2022LAY711X2132LAY711X3042LAY711X3122
LAY711XB2022LAY711XB2132LAY711XB3042LAY720XB3022LAY720XB3322
LAY720X3022
Flush Button
Name NO + NC Type Color InstallationReference
Unit: MM
Dimension
Reference
Unit: MM
Dimension
34
Green
Red
Selective SwitchesName TypeNO + NC Operation Color Installation
p
p
p
p
p
Green
Red
Black
Green
Red
Black
X Selectivebutton withshort handle
XB Selectivebutton withlong handle
JN Full protection
Order Information
LAY7 Pushbutton SwitchesStandard: IEC 60947-5
194
Industrial Control
Com
ponents
LAY7 Pushbutton Switches
Order Information
Y LAY711Y202LAY711Y212LAY711Y302LAY711Y312LAY720Y332
LAY7
2 223 254 30
20:2 C R
21:2 C R
30:3 L C R
31:3 L C R
33:3 L C R
M
MZS
LAY711M32LAY711M42
LAY711MZS32LAY711MZS42
LAY7
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO 01: 1NC20: 2NO 02: 2NC11: 1NO+1NC
2 223 254 30
2 223 254 30
34
34
Key-operated Selective Switches
Name Type OperationNO + NC Installation
Key-operated p
p
p
p
p
Name NO + NC Type InstallationColor
GreenRed
Green
Red
Mushroom Button
Momentary
Reference
Unit: MM
Dimension
Reference
Unit: MM
Dimension
Maintained
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
Standard: IEC 60947-5
195
Com
ponentsIndustrial C
ontrol
LAY710ZS32LAY701ZS42
LAY711ZS32LAY711ZS42
LAY7
Emergency Stop ButtonName NO + NC Type Color Installation
Reference
Unit: MM
Dimension
LAY7 *
Illuminated Pushbutton SwitchesName TypeNO + NC Voltage LightInstallation
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380VThe pure white and pure blue are only available for LED lamp.
Reference
Unit: MM
Dimension
Order Information
LAY7 Pushbutton Switches
Color
10: 1NO 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC
ZS:Emergency
NLBlank:
Neon
LED
Filament
3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue
10: 1NO 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC
D: Momentary (Illuminated)
T: 6V B: 24V F: 110V N: 230V Q: 380V
2: Φ22 3: Φ25 4: Φ30
2: Φ22 3: Φ25 4: Φ30
3: Green 4: Red
*LAY711D3*2LAY711D4*2LAY711D5*2LAY711D6*2LAY711D7*2LAY711D8*2
******
NL
Neon
LEDBlank:Filament
10: 1NO 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC
DZS: Maintained (Illuminated)
T: 6V B: 24V F: 110V N: 230V Q: 380V
3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue
2: Φ22 3: Φ25 4: Φ30
LAY711DZS2*2LAY711DZS4*2LAY711DZS5*2LAY711DZS6*2LAY711DZS7*2LAY711DZS8*2
******
NL
Neon
LEDBlank:Filament
10: 1NO 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC
DM: Momentary (Illuminated)
T: 6V B: 24V F: 110V N: 230V Q: 380V
3: Green 4: Red
2: Φ22 3: Φ25 4: Φ30
LAY711DM3*2LAY711DM4*2
**
NL
Neon
LEDBlank:Filament
10: 1NO 01: NC 20: 2NC 02: 2NC 11: 1NO+1NC
DMZS: Maintained (Illuminated)
T: 6V B: 24V F: 110V N: 230V Q: 380V
3: Green 4: Red
2: Φ22 3: Φ25 4: Φ30
LAY711DMZS3*2LAY711DMZS4*2
**
Standard: IEC 60947-5
196
Industrial Control
Com
ponents
LAY7 Pushbutton Switches
Order Information
LAY7
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
T: 6VB: 24VF: 110VN: 230VQ: 380V
XD1XD2XD3
LAY7XD11*2LAY7XD23*2LAY7XD34*2LAY7XD15*2LAY7XD26*2LAY7XD37*2LAY7XD38*2
LAY7
T: 6VB: 24VF: 110VN: 230VQ: 380V
2 22
BE LAY7BE101LAY7BE102LAY7BE103LAY7BE104LAY7BE105
LAY7
101: 1NO 102: 1NC103: 2NO104: 2NC105: 1N0+1NC
*
*
2 223 254 30
Illuminated Selective Switches
Reference
Unit: MM
Dimension
Reference
Unit: MM
Dimension
Name OperationTypeNO + NC Color Voltage LightInstall
34
Green
Red C R
L C R
20:2p
30:3p
NLBlank:
Neon
LED
Filament
Indication LampName Color Voltage InstallType
Neon
LED
Filament 1345678
WhiteGreen
RedYellow
BluePure whitePure blue
Base
Name Type Contact
Auxiliary contact
Reference
Unit: MM
Dimension
Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380VThe pure white and pure blue are only available for LED lamp.
XD: Selective (Illuminated)
*
22
**
LAY711XD203*2LAY711XD204*2LAY711XD303*LAY711XD304*
**
Standard: IEC 60947-5
197
Com
ponentsIndustrial C
ontrol
Function LAY8 series of pushbutton switches provide:Control and indicate the status of the circuit
AC-15
DC-13
(Ue)
(Ie)
m
V
mA
230 380AC
20
6 12 24 36 48 110 220AC, DC
50
Usage mode Rated valve
(Ue)(Ie)
(Ue)(Ie)
VA
VA
Rated voltageRated current
Rated voltageRated current
Mechanical endurance 105
Electric endurance 105
3802.5
2300.4
6601.5
4400.2
2304.5
1100.8
1050
IP55
30 3
6( )
SelectiveKey-tpyeEmergency stop,0.5
Flush type
Key-tpyeEmergency stop,0.5
Flush type 1( )Illuminated
(Ith)ARated thermal current
Protect degreeContact resistance
Illuminated pushbutton
Rated working voltage
Rated working currentPower supply
Technical Data
LAY8 Pushbutton Switches
≤≤
≤
,
,
-5 ~+40
50%(40 ) 90%(20 )
2000m
3
Temperature
Ralative humidity
Above sea level
Pollution grade
Working Condition
≤
≤
Standard: IEC 60947-5
198
Industrial Control
Com
ponents
LAY8 Pushbutton Switches
LAY811BN1LAY811BN2LAY811BN3LAY811BN4LAY811BN5LAY811BN6
LAY811BNZS3LAY811BNZS4LAY811BNZS5
LAY811S3LAY811S4LAY811S5
LAY8
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
Flush Button
Name NO + NC Type Color
BN Momentary
BNZS Maintained
S Waterproof
123456
WhiteBlackGreenRedYellowBlue
345
GreenRedYellow
345
GreenRedYellow
Reference
Unit: MM
Dimension
Order Information
Standard: IEC 60947-5
199
Com
ponentsIndustrial C
ontrol
LAY811X202LAY811X213LAY811X304LAY811X312LAY820X332
LAY811XB202LAY811XB213LAY811XB304LAY811XB312LAY820XB332
LAY8
234
234
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
20:2 C R
21:2 C R
30:3 L C R
31:3 L C R
33:3 L C R
20:2 C R
21:2 C R
30:3 L C R
31:3 L C R
33:3 L C R
Reference
Unit: MM
Dimension
Selective SwitchesName TypeNO + NC Operation Color
p
p
p
p
p
X Selectivebutton withshort handle
XB Selectivebutton withlong handle
p
p
p
p
p
GreenRed
Black
Green
Red
Black
LAY8 Pushbutton Switches
Order Information
Standard: IEC 60947-5
200
Industrial Control
Com
ponents
Y
LAY8
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
20:2 C R
21:2 C R
30:3 L C R
31:3 L C R
33:3 L C R
LAY811M3LAY811M4
LAY811MZS3LAY811MZS4
LAY8
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO 01: 1NC
20: 2NO02: 2NC11: 1NO+1NC
LAY811Y20LAY811Y21LAY820Y30LAY811Y31LAY811Y33
Key-operated Selective Switch
Name Type OperationNO + NC Reference
Unit: MM
Dimension
Key-operated p
p
p
p
p
Reference
Unit: MM
DimensionName NO + NC Type Color
Mushroom Button
M Momentary 34
GreenRed
34
GreenRed
MZS Maintained
LAY8 Pushbutton Switches
Order Information
Standard: IEC 60947-5
201
Com
ponentsIndustrial C
ontrol
LAY8 Pushbutton Switches
Order Information
ZS LAY811ZS3LAY811ZS4
LAY8
34
Emergency Stop ButtonName NO + NC Type Color
Reference
Unit: MM
Dimension
Emergency Green
Red
LAY8
LAY811D3*4LAY811D4*4LAY811D5*2LAY811D6*2LAY811D7*2LAY811D8*2
LAY811DZS4*4LAY811DZS3*4
LAY811DZS5*2
LAY811DZS7*4LAY811DZS6*2
LAY811DZS8*4
LAY811DS3*4LAY811DS4*4LAY811DS5*2
*Reference
Unit: MM
Dimension
Illuminated Pushbutton Switches
Name TypeNO + NC VoltageColor Power
Note:Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380VThe pure white and pure blue are only available for LED lamp.
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
10: 1NO01: 1NC20: 2NO02: 2NC11: 1NO+1NC
DZS: Maintained (Illuminated)
D: Momentary (Illuminated)
T: 6V B: 24V F: 110V N: 230V Q: 380V
3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue
T: 6V B: 24V F: 110V N: 230V Q: 380V
3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue
2: AC/DC 4: AC
2: AC/DC 4: AC
DS:Waterproof (Illuminated)
T: 6V B: 24V F: 110V N: 230V Q: 380V
3: Green 4: Red 5: Yellow 6:Blue 7:Pure white 8:Pure blue
2: AC/DC 4: AC
Standard: IEC 60947-5
202
Industrial Control
Com
ponents
LAY8 Pushbutton Switches
Order Information
101: 1NO102: 1NC103: 2NO104: 2NC105: 1N0+1NC
LAY8BE101LAY8BE102LAY8BE103LAY8BE104LAY8BE105
LAY8
BE
Base
Name Type Contact
Auxiliary contact
Reference
Unit: MM
Dimension
Standard: IEC 60947-5
203
Com
ponentsIndustrial C
ontrol
2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 160 80 100 125 160 200 250 125 160 200 250 300 315 355 400 315 355 400 450 500 630
Order Information
RT16002 RT16004 RT16006 RT16008 RT160010 RT160012 RT160016 RT160020 RT160025 RT160032 RT160040 RT160050 RT160063 RT160080 RT1600100 RT1600125 RT1600160 RT16180 RT161100 RT161125 RT161160 RT161200 RT161250 RT162125 RT162160 RT162200 RT162250 RT162300 RT162315 RT162355 RT162400 RT163315 RT163355 RT163400 RT163450 RT163500 RT163630
ReferenceFuse-link Rate current In(A) Suitable fuse bases
RT16-00
RT16-1
RT16-2
RT16-3
Weight(g)
170
450
660
850
RT16-00
RT16-1
RT16-2
RT16-3
RT16 FuseStandard: IEC 60269
Function RT16 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current
204
Industrial Control
Com
ponents
Technical Data
Accessory-puller
Order Information
RT16 FuseStandard: IEC 60269
ReferenceFuse Base Rate current In(A) Material Weight(g)
Ceramic Resin Ceramic Resin Ceramic Resin Ceramic Resin
RT1600ZTRT1600ZSRT161ZTRT161ZSRT162ZTRT162ZSRT163ZTRT163ZS
RT16-00
RT16-1
RT16-2
RT16-3
160
250
400
630
200
700
1150
1280
Material Usage Reference
ABS(frame resistance) Assemble and replace RT16 fuse RT16C
Rated working current 2-630A
Rated operation voltage 500/660V
Rated breaking capacity 120KA(500V), 50KA(660V)
205
Com
ponentsIndustrial C
ontrol
a
b
c
d
e
A
B
C1
C2
D
E
F
G
78.5
29
57
49
6
30
120
61
85
100
25
7.5
135
48
62
67
6
58
200
83
96
175
25
10.5
30
150
58
72
67
6
64
250
99
112
200
25
10.5
30
150
67
85
67
6
64
250
105
120
210
25
10.5
30
Unit: mm
Overall Dimensions
RT16 FuseStandard: IEC 60269
RT16-00 RT16-1 RT16-2 RT16-3Type
206
Industrial Control
Com
ponents
RT18 FuseStandard: IEC 60269
Function RT18 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current
ReferenceCylindrical Fuse Rate current In(A) Weight(g)
2 4 6 8 1012162025322 4 6 8 101216202532405063
RT1810382RT1810384RT1810386RT1810388RT18103810RT18103812RT18103816RT18103820RT18103825RT18103832RT1814512RT1814514RT1814516RT1814518RT18145110RT18145112RT18145116RT18145120RT18145125RT18145132RT18145140RT18145150RT18145163
RT18-32
RT18-63
8
20
Order Information
207
Com
ponentsIndustrial C
ontrol
RT18 FuseStandard: IEC 60269
1P
2P
3P
1P
2P
3P
1P
2P
3P
1P
2P
3P
1P
2P
3P
1P
2P
3P
Material:Resin
With Indicator
Material:Resin
Material:Nylon
With Indicator
Material:Nylon
Material:Resin
With Indicator
Material:Resin
RT1832ZXB
RT1832Z2XB
RT1832Z3XB
RT1832ZB
RT1832Z2B
RT1832Z3B
RT1832ZX
RT1832Z2X
RT1832Z3X
RT1832Z
RT1832Z2
RT1832Z3
RT1863ZXB
RT1863Z2XB
RT1863Z3XB
RT1863ZB
RT1863Z2B
RT1863Z3B
RT18-32X
RT18-32
RT18-32X
RT18-32
RT18-63X
RT18-63
32
32
32
32
63
63
82
82
82
82
206
206
Rated working current 2-63A
Rated operation voltage 380V
Rated breaking capacity 100KA
Order Information
Technical Data
Holder of fuse PoleRate current In(A)
NoteWeight (g)
Reference
Without Indicator
Without Indicator
Without Indicator
208
Industrial Control
Com
ponents
RT18 FuseStandard: IEC 60269
Overall Dimensions
RT18-32RT18-63
10×3814×51
10.513.8
38±0.651 -1.0
+0.6
10.3±0.114.3±0.1
Type Size L C Hmax
Cylindrical Fuse
Unit: mm
RT18-32RT18-63
Type A B C D E F G
6378
6076
79103
3535
80110
1825
5475
Holder of fuse
209
Com
ponentsIndustrial C
ontrol
CCF Series Cable Connector
.
Thread specification: International metric standardMaterial: Nylon 66Working temp.: -40℃~+100℃Max temp. in short time: +120℃Installation: Standard threaded holeColour: Black & gray
Technical Data
7.6-4.6 12 12.5 8.5 18/19 CCFMG12IP68B CCFMG12IP68W
10-6 16 16.5 15 22/22 CCFMG16IP68B CCFMG16IP68W
14-9 20 20.5 15 27/27 CCFMG20IP68B CCFMG20IP68W
18-13 25 25.5 15 33/33 CCFMG25IP68B CCFMG25IP68W
25-18 32 33 15 41/41 CCFMG32IP68B CCFMG32IP68W
30-24 40 41 20 50/50 CCFMG40IP68B CCFMG40IP68W
41-30 50 51 22 62/62 CCFMG50IP68B CCFMG50IP68W
51-40 63 64 25 75/75 CCFMG63IP68B CCFMG63IP68W
7-3.5 7 12.5 8 17/19 B CCFPG7IP54W
8-4.5 9 15.2 8.5 22/19 B CCFPG9IP54W
10.5-6 11 18.6 9 24/22 CCFPG11IP54W
12.5-7.5 13.5 20.4 9.6 27/24 B CCFPG135IP54W
14-8.5 16 22.5 10 30/27 C B CCFPG16IP54W
18-12.5 21 28.3 12 36/33 CCFPG21IP54W
25-18 29 37 15 46/41 CCFPG29IP54W
30-23 36 47 15 57/50 CCFPG36IP54W
39-30 42 54 15.5 64/62 CCFPG42IP54W
45-35 48 59.3 15.5 70/65 CCFPG48IP54W
GrayPanel hole(mm)
Thread external diameter (mm)
Cabel range (mm) Black
ReferenceSpanner sizeA&F
Threadlength(mm)
Order Information
---
---
---
---
---
---
---
---
---
---
210
Industrial Control
Com
ponents
Industrial Plugs&Sockets Overview
CDSF Fixed Industrial Sockets
Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A
CDPS Multi-function Plugs and Sockets
Pole: 2P+E Voltage:110V, 230V Current:16A
CDSM Moving Industrial Sockets
Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A
CDPM Moving Industrial plugs
Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A
CDP Fixed Industrial Plugs
Pole: 2P+E~3P+N+E Voltage:110~415V Current:16,32,63,125A
211
212
213
214
215
211
Com
ponentsIndustrial C
ontrol
63
125
63
125
63
125
2P+E
3P+E
3P+N+E
CDPM363IP67
CDPM3125IP67
CDPM463IP67
CDPM4125IP67
CDPM563IP67
CDPM5125IP67
230-25067
400-41567
400-415 67
Moving Industrial Plugs
CDPM Moving Industrial PlugsStandard: IEC 60309-1-2
b
a
PG
16Amp 32Amp
63Amp 125Amp
295
124
50
295
124
50
3 4
295
124
50
5
230
109
36
230
109
36
230
109
36
3 4 5
a b c
212
Industrial Control
Com
ponents
CDP Fixed Industrial Plugs
Fixed Industrial Plugs
63Amp
319312215710919628812729
419312215710919628812729
519312215710919628812729
abcdefghPG
CDP316IP44
CDP332IP44
CDP416IP44
CDP432IP44
CDP516IP44
CDP532IP44
CDP316IP441
CDP332IP441
CDP363IP67
67
67
67 63
63
63
3P+E
3P+N+E
CDP463196
CDP5631967
230~250
400~415
400~415
Standard: IEC 60309-1-2
213
Com
ponentsIndustrial C
ontrol
CDSM316IP441
CDSM363IP67
CDSM3125IP67
63
125
67
2P+E
CDSM463IP67
CDSM4125IP67
63
125
67
67
3P+E
3P+N+E
CDSM563IP67
CDSM5125IP67
63
125
63Amp 125Amp
324011236
424011236
524011236
330012650
430012650
530012650
abPG
Moving Industrial Sockets
CDSM Moving Industrial Sockets
230~250
400~415
400~415
a
b PG
32Amp16Amp
3 4 53 4 5
Standard: IEC 60309-1-2
a 131 139 149 149 154
100 90 90 9076 66 b
130
Poles
214
Industrial Control
Com
ponents
CDSF Fixed Industrial Sockets
Fixed Industrial Sockets
Pole No. IPNominalvoltage(V)
Nominalcurrent(A) Reference
44
44
44
110~130
230~250
400~415
16
32
16
32
16
32
16Amp
PolesabM
32Amp
31288625
41289025
51299625
31419725
51419725
514310425
3P+E
2P+E
2P+E
CDSF316IP441
CDSF332IP441
CDSF316IP44
CDSF332IP44
CDSF416IP44
CDSF432IP44
44
230~400
240~415
16
32
63
125
63
125
63
125
67
67
67
230~250
400~415
230~400
240~415
3P+N+E
2P+E
Polesabcdefgh
PG
3193122157109196
27013029
4193122157109196
27013029
5193122157109196
27013029
3220140185130178
32015036
4220140185130178
32015036
5220140185130178
32015036
CDSF516IP44
CDSF532IP44
CDSF363IP67
CDSF3125IP67
CDSF463IP67
CDSF4125IP67
CDSF563IP67
CDSF5125IP67
3P+E
3P+N+E
63Amp 125Amp
Standard: IEC 60309-1-2
215
Com
ponentsIndustrial C
ontrol
1 Plug
1 Plug
1 Plug
1 Plug
Multi-function Plugs and Sockets
CDPS Multi-function Plugs&SocketsStandard: IEC 60309-1-2
216
Industrial Control
Com
ponents
Copper Terminal Block Overview
TB010
Hole:4, 6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150
TB019
Hole:4, 6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150
TB007
Hole:6, 8, 10, 12, 14, 16 Hole diameter(mm):5.2, 6 Screw dimension(mm):M4*8, M5*10 Max current(A):100, 150
TB043
Hole:78, 109, 116, 133 Hole diameter(mm):5~9 Screw dimension(mm):M4*8~M6*12 Max current(A):100~200
TB112
Hole:2x7, 2x15, 4x7, 4x11, 4x15 Hole diameter(mm):5.2 Screw dimension(mm):M4 Max current(A):125
Copper Terminal Block Overview
217
218
219
220
220
217
Com
ponentsIndustrial C
ontrol
TB010 Series Copper Terminal Block
Order Information
218
Industrial Control
Com
ponents
TB019 Series Copper Terminal Block
Order Information
219
Com
ponentsIndustrial C
ontrol
TB007 Series Copper Terminal Block
Order Information
220
Industrial Control
Com
ponents
TB112 Series Copper Terminal Blocks TB043 Series Copper Terminal Blocks
Order Information
6513265
132
221
Com
ponentsIndustrial C
ontrol
CDIN01E*
CDIN01N*
CDIN02T*
0.8
0.9
1.0
DIN Rail Series
Order Information
Overall Dimensions
1000=1000mm
2000=2000mm
5000=5000mm
means length*
ReferenceThickness(mm)
Unit:mm
222
A Company to Serve You Where You Are
AlgeriaPhone: +213 5 600 600 11
ChilePhone:+56-2-4822100
Colombia / Venezuela / Ecuador / Peru / BoliviaPhone:+57 3212056531
EgyptPhone:+20 10 011 3238 - +20 11 811 3546
IsraelPhone:+972 543311087
Kenya / Tanzania / Uganda / Rwanda / BurundiPhone:+97150 5536433
MalaysiaPhone:+601 93227688
MoroccoPhone:+212 661 114 6999
Nigeria / Ghana / LiberiaPhone:+234 8035059040
Philippines / Laos / Bangladesh Phone:+86 158 6807 8915
Pakistan Phone:+92 300 8465 789
Russia / KazakhstanPhone: +7 916 693 59 84
Santo Domingo / Trinidad andTobago / JamaicaPhone: +809 861 5803
Saudi Arabia / YemenPhone:+966-50 440 62 69
Turkey / Romania / Serbia / Bulgaria / Macedonia / Montenegro / Albania / Moldova / Syria / Lebanon / Jordan / Iran / Iraq / Central Asia Phone:+90 5335256771
UAE / Qatar / Oman / Bahrain / Kuwait Phone:+97150 5536433
Vietnam / Cambodia Phone:+8490 381 3973
E-mail Address:[email protected]
223
Memo
224
Memo
Jan.2011