1 7063-513 March 17, 2014
VOYAGEUR WOOD INSERTAutomatic Combustion Control (ACC)
Model(s):VOYAGEUR-MBKVOYAGEUR-PMH
HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
Hot glass will cause burns.• Do not touch glass until it is cooled• NEVER allow children to touch glass• Keep children away• CAREFULLY SUPERVISE children in same room as
fireplace.• Alert children and adults to hazards of high temperatures• High temperatures may ignite clothing or other
flammablematerials.• Keepclothing, furniture,draperiesandotherflammable
materials away.
WARNING
If the information in these instruc-tions is not followed exactly, a firemayresultcausingpropertydamage, personal injury, or death.
• Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthis or any other appliance.
• Donotoverfire-Ifheaterorchimneycon-nectorglows,youareoverfiring.Overfiringwillvoidyourwarranty.
• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.
WARNINGFire Risk.For use with solid wood fuel only.Otherfuelsmayoverfireandgeneratepoisonousgases(i.e.carbonmonoxide).
Installationandserviceofthisapplianceshouldbeperformedbyqualifiedpersonnel.Hearth&HomeTechnologiesrecommendsNFIcertifiedprofessionals,ortechnicianssupervisedbyanNFIcertifiedprofessional.
WARNING
Installation ManualInstallation & Appliance Set-Up
INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.
NOTICE: DO NOT DISCARD THIS MANUAL
NOTEToobtainaFrenchtranslationofthismanual,pleasecontactyourdealerorvisitwww.quadrafire.com
Pourobtenirunetraductionfrançaisedecemanuel,s’ilvousplaîtcontactervotrerevendeurouvisitezwww.quadrafire.com
2 7063-513 March 17, 2014
VOYAGEUR
TABLE OF CONTENTS
Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwill result in death or serious injury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedmay result in death or serious injury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,may result in minor or moderate injury.• NOTICE: Indicates practices which may cause damage to the appliance or to property.
1 Important Safety InformationA.InsertCertification .............................................................3B.BTU&EfficiencySpecifications........................................3C.MobileHomeApproved .................................................... 3D.GlassSpecifications .........................................................3E.Non-CombustibleMaterials ...............................................3F.CombustibleMaterials ........................................................3
2 Getting StartedA. Design and Installation Considerations ................................4B. Draft ..............................................................................4C.NegativePressure ...........................................................5D.ToolsAndSuppliesNeeded .............................................5E. Inspect Appliance and Components ................................5F. Install Checklist ...............................................................6
3 Dimensions and ClearancesA. Appliance Dimensions ......................................................7B.ClearancestoCombustibles ..............................................8C. Calculating Alternate Floor Protection ..............................10D.LocatingYourStove&Chimney .......................................11E.ChimneyTerminationRequirements .................................11F. 2-10-3 Rule .......................................................................12
4 Chimney SystemsA. Venting Systems ...............................................................13B. Inspections........................................................................13C. Larger Chimneys ..............................................................13D. Masonry Chimney.............................................................13E.MetalHeatCirculatingMasonry.......................................15F.PrefabricatedMetalChimney ............................................15G. Securing Chimney Components.......................................16H.AlteringtheFireplace ........................................................16I. Zero-Clearance Fireplace ..................................................17J.OvalizingRoundStainlessSteelLiners ............................17K.ChimneyHeight/RiseandRun .......................................17
5 Appliance Set-UpA.OutsideAirKitInstallation ..................................................18B.SecuringStovePipe/LinertoFlueCollar ..........................19C.LevelingLegs ...................................................................19D.OptionalElbowFlueAdapterInstallation ..........................19E.SecuringAppliancetoStovePipe/Liner............................20F.Surround&TrimKitInstallation .........................................20G.StandardSurround&CastTrimKit .................................21H.AllCastSurroundKit .......................................................22I. Blower Cord Installation on Left Side ................................22
6 Mobile Home Installation7 Accessory List
A. Accessory List ....................................................................26B.ServiceandMaintenanceLog ...........................................27
March 17, 2014 7063-513 3
VOYAGEUR
TheQuadra-FireVoyageurmeetstheU.S.EnvironmentalProtectionAgency’s1990particulateemissionstandards.
Model: Voyageur Wood Insert
Laboratory: IntertekReport No: 100116597
Type: SolidFuelType,ListedRoomHeater
Standard: UL1482 and ULC S628-93 and (UM)84-HUD,MobileHomeApproved.
EPACertified: 4.1 grams per hour
Efficiency: 77.6%
EPA BTU Output: 11,550 to 23,930
Heating Capacity: 1,303to2,335sqftdepend-ing on climate zone
Vent Size: 6 inches
Firebox Size: 1.87cubicfeet
Max Wood Length: 18 inches
Max First Hour BTUs: 53,100 @ 75.3% B415 TestedEfficiency
Fuel: Cord Wood
Shipping Weight: 355lbs
1 Important Safety InformationA.InsertCertification
NOTE:Hearth&HomeTechnologies,manufacturerofthisappliance,reservestherighttoalteritsproducts,theirspecificationsand/orpricewithoutnotice.
C. Mobile Home Approved • Thisapplianceisapprovedformobilehomeinstalla-
tions when not installed in a sleeping room and when anoutsidecombustionairinletisprovided.
• Thestructuralintegrityofthemobilehomefloor,ceil-ing,andwallsmustbemaintained.
• Theappliancemustbeproperlygroundedtotheframeofthemobilehomewith#8coppergroundwire,andchimneymustbe listed toUL103HTora listedUL-1777fulllengthsixinch(152mm)diameterlinermustbeused.
• OutsideAirKit,partOAK-ACCmustbeinstalledinamobilehomeinstallation.
Improper installation, adjustment, alteration, service ormaintenance can cause injury or property damage. Forassistanceoradditionalinformation,consultaqualifiedinstaller,serviceagencyoryourdealer.
Quadra-FireisaregisteredtrademarkofHearth&HomeTechnologies.
•Installationanduseofanydamagedappliance.•Modificationoftheappliance.• Installation other than as instructed by Hearth & HomeTechnologies.•Installationand/oruseofanycomponentpartnotapprovedbyHearth&HomeTechnologies.•Operatingappliancewithoutfullyassemblingallcomponents.•Operatingappliancewithoutlegsattached(ifsuppliedwithunit).•DoNOTOverfire-Ifapplianceorchimneyconnectorglows,youareoverfiring.Anysuchactionthatmaycauseafirehazard.
WARNING
Fire Risk.
Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:
B.BTU&EfficiencySpecifications
D.GlassSpecificationsThisstoveisequippedwith5mmceramicglass.Replaceglass only with 5mm ceramic glass. Please contact your dealer for replacement glass.
Hearth&HomeTechnologiesWILLNOTwarrantystovesthatexhibitevidenceofover-firing.Evidenceofover-firingincludes,butisnotlimitedto: • Warpedairtube • Deterioratedrefractorybrickretainers • Deterioratedbaffleandotherinteriorcomponents
E. Non-Combustible MaterialsMaterialwhichwillnotigniteandburn,composedofanycombinationofthefollowing: - Steel - Plaster - Brick - Iron -Concrete -Tile - Glass - SlateMaterials reported as passing ASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C.
F. Combustible MaterialsMaterialmadeof/orsurfacedwithanyofthefollowingma-terials: - Wood - Compressed Paper -PlantFibers -Plastic -Plywood/OSB -SheetRock(drywall)Anymaterialthatcanigniteandburn:flameproofedornot,plastered or un-plastered.
NOTE:Thisinstallationmustconformwithlocalcodes.IntheabsenceoflocalcodesyoumustcomplywiththeUL1482,(UM)84-HUDandNPFA211intheU.S.A.andtheULCS628-93andCAN/CSA-B365InstallationCodesinCanada.
4 7063-513 March 17, 2014
VOYAGEUR
Install Guide2 Getting Started
A. Design and Installation Considerations
Beforeinstalling,determinethefollowing:
• Typeofchimneyconnectortobeused · singlewall,6inch(152mm)diameter,stainlesssteel,or ·doublewall,6inch(152mm)diameter,stainlesssteel• Consultpage28forclearancestocombustibles• Poweroutletlocatedclosebyforoptionalblower
B. DraftDraft is thepressuredifferenceneededtoventappliancessuccessfully. When a appliance is drafting successfully, all combustion byproducts are exiting the home through thechimney.Considerationsforsuccessfuldraftinclude:• Preventingnegativepressure• LocationofapplianceandchimneyTobesurethatyourapplianceburnsproperly:• Duringalowburn,thechimneydraft(staticpressure)should
beapproximately-.04inchwatercolumn(W.C.)• Duringahighburnthechimneydraftshouldbeapproximately
-.10inch(W.C.)• MeasuretheW.Cat6inches(152mm)abovethetopofthe
applianceafteronehourofoperationateachburnsetting.
NOTICE: Hearth & Home Technologies assumes no
Checkbuildingcodespriortoinstallation.
• InstallationMUST complywith local, regional, state andnational codes and regulations.
• Consult insurance carrier, local building, fire officials orauthoritieshavingjurisdictionaboutrestrictions,installationinspection, and permits.
CAUTION
WARNING
• DONOTCONNECTTHISUNITTOACHIMNEYFLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
Mayallowfluegasestoenterthehouse.
Asphyxiation Risk.
• Installationanduseofanydamagedappliance.• Modificationoftheappliance.• Installation other than as instructed byHearth &Home
Technologies.• Installationand/oruseofanycomponentpartnotapproved
byHearth&HomeTechnologies.• Operatingappliancewithoutfullyassemblingallcomponents.• Operatingappliancewithoutlegsattached(ifsuppliedwith
unit).• DoNOTOverfire-Ifapplianceorchimneyconnectorglows,
youareoverfiring.Anysuchactionthatmaycauseafirehazard.
WARNINGFire Risk.Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:
responsibility for the improper performance of theappliancesystemcausedby:
• Inadequatedraftduetoenvironmentalconditions• Downdrafts• Tightsealingconstructionofthestructure• Mechanicalexhaustingdevices• Overdraftingcausedbyexcessivechimneyheights• Idealperformanceiswithheightofchimneybetween
14-16feet(4.26-4.88m)measuredfromthebaseofthe appliance.
March 17, 2014 7063-513 5
VOYAGEUR
C. Negative Pressure Negativepressure results from the imbalanceofair avail-ablefor theappliancetooperateproperly. Itcanbestron-gestinlowerlevelsofthehouse.
Causesinclude:
• Exhaustfans(kitchen,bath,etc.)• Rangehoods• Combustionairrequirementsforfurnaces,waterheaters
andothercombustionappliances• Clothesdryers• Locationofreturn-airventstofurnaceorairconditioning• ImbalancesoftheHVACairhandlingsystem• Upperlevelairleakssuchas: - Recessed lighting - Attic hatch - Duct leaks
Tominimizetheeffectsofnegativeairpressure:• Installtheoutsideairkitwiththeintakefacingprevailing
winds during the heating season• Ensureadequateoutdoorairforallcombustionappliances
andexhaustequipment• Ensurefurnaceandairconditioningreturnventsarenot
locatedintheimmediatevicinityoftheappliance• Avoid installing theapplianceneardoors,walkwaysor
small isolated spaces• Recessedlightingshouldbea“sealedcan”design• Attichatchesweatherstrippedorsealed• Atticmountedductworkandairhandlerjointsandseams
taped or sealed• Basementinstallationsshouldbeavoided
D. Tools And Supplies Needed Beforebeginningtheinstallationbesurethefollowingtoolsandbuildingsuppliesareavailable:
Reciprocating saw Framing material
Pliers Hightempcaulkingmaterial
Hammer Gloves
Phillipsscrewdriver Framingsquare
Flatbladescrewdriver Electricdrillandbits
Plumbline Safetyglasses
Level Tapemeasure
Misc. screws and nails
1/2-3/4in.length,#6or#8self-drillingscrews
E. Inspect Appliance and Components• Removeapplianceandcomponentsfrompackagingand
inspect for damage.• Vent system components and doors are shipped in
separate packages.• Reporttoyourdealeranypartsdamagedinshipment.• Readalltheinstructionsbeforestartingtheinstallation.
Follow these instructions carefully during the installationtoensuremaximumsafetyandbenefit.
Inspect appliance and components for damage. Damaged parts may impair safe operation.
WARNING
• DoNOTinstalldamagedcomponents.• DoNOTinstallincompletecomponents.• DoNOTinstallsubstitutecomponents.Report damaged parts to dealer.
Fire Risk.
WARNING
• Negativepressurecancausespillageofcombus-tionfumes,sootandcarbonmonoxide.
• Applianceneedstodraftproperlyforsafety.
Asphyxiation Risk.
6 7063-513 March 17, 2014
VOYAGEUR
ATTENTION INSTALLER:Follow this Standard Work Checklist
Thisstandardworkchecklististobeusedbytheinstallerinconjunctionwith,notinsteadof,theinstructionscontainedinthisinstallationmanual.
Customer: Date Installed: Lot/Address: Location of Fireplace: Installer: Dealer/ Distributor Phone #: Serial #: Model (circle one): VOYAGEUR-MBK VOYAGEUR-PMH
WARNING! Risk of Fire or Explosion! Failuretoinstallfireplaceaccordingtotheseinstructionscanleadtoafireorexplosion.
Appliance Install Verifiedclearancestocombustibles.(Pg.8)Fireplaceisleveledandlinerissecuredtoappliance.(Pg.18)Hearthextensionsize/heightdecided.(Pg.22)Outsideairkitinstalled.(Pg.15)Floorprotectionrequirementshavebeenmet.Themasonrychimneyisinspectedbyaprofessionalandiscleanorthefactorybuiltmetalchimneyisinstalledaccordingtothemanufacturer’s instructions and clearances.
Chimney Section 4 (Pg. 10)Chimneyconfigurationcomplieswithdiagrams.Chimney installed, locked and secured in place with proper clearance. Chimneymeetstheminimumheightrequirements.Roofflashinginstalledandsealed.Terminationsinstalledandsealed.
Clearances Section 3 (Pg. 7)Combustiblematerialsnotinstalledinnon-combustibleareas.Verifiedallclearancesmeetinstallationmanualrequirements.Mantelsandwallprojectionscomplywithinstallationmanualrequirements.Protectivehearthstripsandhearthextensioninstalledpermanualrequirements.
Appliance Setup Section 5 (Pg. 15)Allpackagingandprotectivematerialsremoved.Firebrick,baffleandceramicblanketinstalledcorrectly.Alllabelshavebeenremovedfromthedoor.Allpackagingmaterialsareremovedfrominside/underthefireplace.Manualbagandallofitscontentsareremovedfrominside/underthefireplaceandgiventothepartyresponsibleforuseandoperation.
Hearth & Home Technologies recommends the following:•Photographingtheinstallationandcopyingthischecklistforyourfile.•Thatthischecklistremainvisibleatalltimesonthefireplaceuntiltheinstallationiscomplete.
Comments: Furtherdescriptionoftheissues,whoisresponsible(Installer/Builder/OtherTrades,etc.)andcorrectiveactionneeded:Commentscommunicatedtopartyresponsible by on (Builder/Gen.Contractor) (Installer)(Date)
Part#4017-254•RevB•01/29/13
YES IF NO, WHY?
F. Install Checklist
March 17, 2014 7063-513 7
VOYAGEUR
Figure 7.1 Top View Figure 7.2 Front View
Figure 7.4 - Side View
A
B20-34/ in. (527mm)
30 in. (762mm) Front
16-7/16 in. (418mm)
12-3/4 in. (324mm)
29-3/16 in. (741mm)
19-1/8 in. (486mm)
18-1/8 in. (460mm)
5 in. (127mm)
9-1/4 in. (235mm)
9-7/8 in. (251mm)
CL
33 in. (838mm)
21-1/2 in. (546mm)
3.0 in. (76mm)
3-7/8 in. (98mm)
10-7/8 in. (276mm)
13-7/8 in. (352mm)
4-1/4 in. (108mm)
CL
1-7/16 in. (37mm)
Surround Sizes A BMetalSurroundw/CastTrimSTD 42.5in.(1080mm) 30in.(762mm)
MetalSurroundw/CastTrimLRG 48in.(1219mm) 34in.(864mm)
All Cast Surround 40in.(1016mm) 30in.(762mm)
MetalSurroundw/StndTrimSTD 43in.(1092mm) 31in.(787mm)
MetalSurroundw/StndTrimLRG 51in.(1295mm) 34in.(2184mm)
A
B30 degree
30o
A
BVertical
Figure 7.3 - Side View With Optional Offset Adapter
Flue Adapter A BVertical 14in.(356mm) 23-3/4in.(603mm)30 Degree 15in.(381mm) 23-1/2in.(597mm)
3 Dimensions and ClearancesA. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID)
8 7063-513 March 17, 2014
VOYAGEUR
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
Fire Risk.• Complywithallminimumclearancesto
combustiblesasspecified.• Failuretocomplymaycausehousefire.
WARNING
InCanadaafulllength6inch(152mm)S635fluelinerrequiredasperULCS628.InUSAaminimum5ftlength(1.82m),6inch(152mm)diameterfluelinerisrequiredasperUL1482.
SID
E TR
IM (3
/4” m
ax)
SID
E W
ALL
TOP TRIM (3/4” max)
21-1/4540mm
31-1/4794mm
HEARTH EXTENSION
USA 18-3/4CANADA
22-3/4 (578mm)
40-3/161021mm
FIR
EPLA
CE
FR
ON
T SU
RFA
CE
USA 17-7/16CANADA 19-7/16 (494mm)
HEARTH EXTENSION
47-3/161199mm
12in max
MANTEL
See next page for thermal protection requirements
Required Protection
Suggested ProtectionNOTE: Keep Ashlip Clear of Ashes
NOTE: Hearth Rug may be used in Suggested Area
B. Clearances to Combustibles UnitedStatesandCanada(ULandULC)
March 17, 2014 7063-513 9
VOYAGEUR
Thermal ProtectionRequired
0 to 7 inch (0 to 178mm)
1 inch (25)mm) R value = 2.04
USA & CANADA ONLY Hearth Height0 to 7 inch
Figure9.2-ThermalProtectionRequired
Factory-Build Solid Fuel Fireplace Floor Protection Under Hearth Extension
Figure9.1-ThermalProtectionRequired
SAFETY TESTING NOTES:
Duringsafetytestingthefollowingmaterialwasusedforthefloorprotectionmaterialunderthehearthextension:
USA: 1/4inch(6.25mm)JamesHardiBoard®,R=0.52
1inchthicknoncombustionboardwithavalueofR-2.04isrequired
SeeAlternativeFloorProtectionWorksheetonpage 10.
10 7063-513 March 17, 2014
VOYAGEUR
C. Calculating Alternate Floor ProtectionMaterial Thermal Conductivity: k valueThekvalueindicatestheamountofheat(inBTU’s)thatwillflowin1hourthrough1squarefootofauniformmaterial1inchthickforeachdegree(F)of temperaturedifferencefromonesideofthe material to the other.
TheLOWER thek factormeans lessheat isbeingconductedthroughthenon-combustiblematerialtothecombustiblematerialbeneathit.
Thekvalueofamaterialmustbeequalorsmallerthenthere-quiredkvaluetobeacceptable. (BTU)(inch) (foot2(hour)(oF)
Thermal Resistance: R valueTheRvalueisameasureofamaterial’sresistancetoheattransfer. RvalueisconvenientwhenmorethanonematerialisusedsinceyoucanaddtheRvaluestogether,whereasyoucannotdothisforkvalue.TheHIGHERtheRfactormeanslessheatisbeingconduct-edthroughthenon-combustiblematerialtothecombustiblematerialbeneathit.TheRvalueofamaterialmustbeequalorlargerthentherequiredRvaluetobeacceptable.Converting k to R:Divide1bykandmultiplytheresultstimesthethicknessininch-es of the material. R=1/kxinchesofthicknessConverting R to k:DividetheinchesofthicknessbyR. k=inchesofthickness/RCalculations:Example:Floorprotectionrequireskvalueof0.84and3/4inchthick.Alternativematerialhasakvalueof0.6andis3/4inchthick.Divide0.6by.75=kvalueof0.80.Thiskvalueissmallerthan0.84andthereforeisacceptable.
March 17, 2014 7063-513 11
VOYAGEUR
Recommended Location
Marginal Location
Location Not
Recommended
Recommended
Location
Location NOT
Recommended
Multi-level Roofs
Windward
Leeward Outside Air Kit Termination Cap
Figure 11.1
E.ChimneyTerminationRequirementsFollowmanufacturer’sinstructionsforclearance,securingflashingandterminatingthechimney. • MusthaveanapprovedandListedcap
• Mustnotbelocatedwhereitwillbecomepluggedbysnow or other material
• Mustterminateatleast3feet(91cm)abovetheroofandatleast2feet(61cm)aboveanyportionoftheroofwithin10feet(305cm).
• Mustbelocatedawayfromtreesorotherstructures
D. Locating Your Stove & ChimneyLocation of the appliance and chimney will affect perfor-mance. As shown in Figure 11.1thechimneyshould: • Installthroughthewarmspaceenclosedbythebuild-
ingenvelope.Thishelpstoproducemoredraft,espe-ciallyduringlightinganddiedownofthefire.
• Penetratethehighestpartoftheroof.Thisminimizestheaffectsofwindturbulenceanddowndrafts.
• Considertheappliancelocationinordertoavoidfloorand ceiling attic joists and rafters.
• Locate termination cap away from trees, adjacent structures,unevenrooflinesandotherobstructions.
Yourlocaldealeristheexpertinyourgeographicareaandcanusuallymakesuggestionsordiscoversolutionsthatwilleasilycorrectyourflueproblem.
NOTICE:• Chimneyperformancemayvary.• Trees,buildings,rooflinesandwindconditionsaffect
performance.• Chimneyheightmayneedadjustmentifsmokingor
overdraftoccurs.
NOTICE: Locating the appliance in a basement or in alocationofconsiderableairmovementcancauseintermittentsmokespillagefromappliance.Donotlocateappliancenear• Frequentlyopendoors• Centralheatoutletsorreturns
12 7063-513 March 17, 2014
VOYAGEUR
3ft.(91cm)Minimum
Lessthan10ft.(305cm)
2ft.(61cm) 3ft.(91cm)Minimum
10ft.(305cm) To Nearest Roofline2ft.(61cm)
Pitched RoofFigure 12.1 Pitched Roof
Figure 12.2 Flat Roof
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm) Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof
F. 2-10-3 Rule
Thesearesafetyrequirementsandarenotmeanttoassureproperfluedraft.
Thisapplianceismadewitha6inch(152mm)diameterchimneyconnectorasthefluecollarontheunit.
• Changingthediameterofthechimneycanaffectdraftandcausepoorperformance. • Itisnotrecommendedtouseoffsetsandelbowsataltitudesabove4000feetabovesealevelandorwhenthere areotherfactorsthataffectfluedraft.
March 17, 2014 7063-513 13
VOYAGEUR
4 Chimney SystemsD. Masonry Chimney •MustmeetminimumstandardsofNFPA211. •Musthaveatleast5/8inch(16mm)fireclayliningjoined
with refractory cement. (Installations into a clay fluewithout a stainless steel liner may reduce draw which affects performance, will cause the glass to darken and produceexcessivecreosote).
•Themasonrywall of the chimney, if brick ormodularblock,mustbeaminimumof4inches(102mm)nominalthickness.
•Achimneyof rubblestonemustbeat least12 inches(305mm)thick.
•Cross-sectional area shall conform toNFPA211-2006Section 12.4.5.1.
•Shouldbe linedwitha6 inch (152mm)stainlesssteelfluelinertoimproveperformanceandreducecreosotebuild-up.
•Anequivalentlinermustbealistedchimneylinersystemorotherapprovedmaterial.
•Nodilutionairisallowedtoenterthechimney. 1. Securethefireplacedamperintheopenposition.If
thiscannotbeaccomplished,itwillbenecessarytoremovethedamper
2. Seal damper area of chimney around chimney connector with a high temperature sealant or seal insertagainstthefaceofthefireplace.
3.Bothmethodsmustberemovableandreplaceablefor cleaning and re-installation.
•Whenpossible, installanairtightclean-outdoor to therear of the smoke shelf.
A. Venting SystemsChimney Connector:Itisalsoknownasfluepipeorstovepipe.Itmustbe6inches(152mm)minimumdiameterstainlesssteelconnectorpipe.Chimney:Thechimneycanbeneworexisting,masonryorprefabricatedandmustmeet the followingminimum requirements asspecifiedbelow.
WARNING! Risk of Fire!Follow ventingmanufacturer’s clearances andinstructionswheninstallingventingsystem.
B. InspectionsExisting chimneys should be inspected and cleaned by aqualifiedprofessionalpriortoinstallation.Thechimneymustnothavecracks,loosemortarorothersignsofdeteriorationandblockage.Hearth&HomerecommendsaNFIorCSIAcertifiedprofessionaloratechnician,underthedirectionofa certified professional, conduct a Level II inspection perNFPA 211.
Fire RiskInspectionofChimney:• Chimneymustbeingoodcondition.• MeetsminimumstandardofNFPA211• Factory-builtchimneymustbe6inch
(152mm)UL103HT.
WARNING
NOTICE:Checkwith your local building authoritiesand/orconsulttheNationalFireProtectionAssociation(NFPA211).
C. Larger ChimneysIt is recommended that chimneys with larger diameters than6 inches (152mm)be relined. Anoversizedfluecanaffect draft and impair performance and will allow increased build-upofcreosote.
14 7063-513 March 17, 2014
VOYAGEUR
UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System
Follow Manufacturer’s Instructions on Insulation and Support
For Zero or Other Non-Code Clearances, Follow Approved Liner Manufacturer’s Specific Insulation Requirements: Different Clearances
May Require Different Specifications
Masonry Chimney Must Have Structural Integrity
UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System
Minimum 8 in. (203mm) Masonry Thickness in Front of Smoke Chamber
Damper Plate Removed or Fastened in Open Position
Seal with Non-Combustible Material
Minimum Clearance in Accordance with Insert Listing
Floor Protection in Accordance with Insert
Listing
Follow Manufacturer’s Instructions for Maximum Liner Extension Above Chimney
Maximum 30 Degrees Offset in Chimney
Combustible Floor
Masonry Chimney (Cont’d)This insert conformswith the UL 1482 andULC S628(Canada)inallrespects,andisapprovedtoUL&ULCsafetystandards for installationandusewithinafireplacewithamasonrychimneyinaccordancewithNFPA211andCAN/CSA-B365-01.
Figure 14.1
NOTE:InCanada,thisfireplaceinsertmustbeinstalledwithacontinuouschimneylinerofa6inch(152mm)diam-eterextending fromthefireplace insert to the topof thechimney.ThechimneylinermustconformtotheClass3requirementsofCAN/ULC-S635,StandardforLiningSys-temsforExistingMasonryorFactory-BuiltChimneysandVents, orCAN/ULC-S640,Standard for LiningSystemsfor New Masonry Chimneys.
Generic Insert Model Shown in Illustration
March 17, 2014 7063-513 15
VOYAGEUR
Figure 15.1
F. Prefabricated Metal ChimneyThechimneycanbeneworexisting,masonryorprefabricatedandmustmeetthefollowingminimumrequirements: •Must beminimum6 inch (152mm) insidediameter of
hightemperaturechimneylistedtoUL103HT(2100oF)or ULC S628.
•Mustusecomponentsrequiredbythemanufacturerforinstallation.
•Mustmaintainclearancesrequiredbythemanufacturerfor installation.
•Refertomanufacturersinstructionsforinstallation •ThisinsertislistedtoUL1482Standardandisapproved
forinstallationintolistedfactory-builtzeroclearancefire-places listed to UL 127 conforming to the following spec-ificationsandinstructions:
•The original factory-built clearance fireplace chimneycap must be re-installed after installing the approvedchimney liner meeting type UL 103 HT requirements(2100°F)perUL1777.
•IfthechimneyisnotlistedasmeetingHTrequirements,orifthefactorybuiltfireplacewastestedpriorto1998,afullheightlistedchimneylinermustbeinstalledfromtheappliancefluecollartothechimneytop.
•Thelinermustbesecurelyattachedtotheinsertfluecollarand the chimney top.
•Theairflowofthefactory-builtzero-clearancefireplacesystemmustnotbealtered.Theflue liner topsupportattachmentmustnotreducetheairflowfortheexistingair-cooled chimney system.
•Nodilutionairisallowedtoenterthechimney. 1. Securethefireplacedamperintheopenposition.If
thiscannotbeaccomplished,itwillbenecessarytoremovethedamper
2. Seal damper area of chimney around chimney connector with a high temperature sealant or seal insertagainstthefaceofthefireplace.
3.Bothmethodsmustberemovableandreplaceablefor cleaning and re-installation.
Minimum 8” (203mm) Masonry Thickness in Front of Smoke Chamber
Damper Plate Removed or Fastened in Open Position
Seal with Non-Combustible Material
Minimum Clearance in Accordance with Insert Listing
Floor Protection in Accordance with Insert
Listing
Combustible Floor
Airtight Insulated Clean-Out
Stainless Steel Chimney Connector Must Extend to Flue Liner
Flue Liner with Required Air Space
E. Metal Heat Circulating Masonry ThisinsertconformswiththesafetystandardUL-1482andULCS628(Canada)inallrespectsandisapprovedtoUL&ULCsafetystandardsfor installationandusewithinafire-place with masonry chimney, in accordance with NFPA 211, withadirectfluecollarconnection.
Generic Insert Model Shown in Illustration
16 7063-513 March 17, 2014
VOYAGEUR
Inches Millimeters
MinimumWidthofCavityOpening-Front 32-7/8* 835MinimumWidthofCavityOpening-Rear 19-1/8* 486MinimumHeight 21-1/2* 546Minimum Depth from Front to Rear 18-1/8* 460
Damper SmokeShelforBaffleEmberCatches Fire GrateViewingScreen/Curtain Doors
Thefollowingpartsmayberemoved:
The following modifications of factory-built fireplaces arepermissible:
• Thefireplacemustnotbealtered.Cuttinganysheetmetalpartsofthefireplaceinwhichthefireplaceinsertistobeinstalled is prohibitedperANSIZ21.88except that thedampermayberemovedtoaccommodateadirect-connectstarter pipe or chimney liner,
• Externaltrimpieceswhichdonotaffecttheoperationofthefireplacemayberemovedprovidingtheycanbestoredonorwithin thefireplace for reassembly if the insert isremoved.
• The permanentmetal warning label provided in thecomponent packmust be attached to the back of thefireplace,withscrewsornails,statingthatthefireplacemayhavebeenalteredtoaccommodatetheinsert,andmustbereturnedtooriginalconditionforuseasaconventionalfireplace.
• Ifthehearthextensionislowerthanthefireplaceopening,theportionoftheinsertextendingontothehearthmustbesupported.
• Manufacturer designed adjustable support kit can beordered from your dealer.
• Finalapprovalofthisinstallationtypeiscontingentupontheauthorityhavingjurisdiction.
Fire Risk.
Whenliningair-cooledfactory-builtchimneys:.• RunchimneylinerapprovedtoUL1777Type
HTrequirements(2100degreesF)• Re-installoriginalfactorybuiltchimneycap
ONLY• DONOTblockcoolingairopeningsinchimney• Blockingcoolingairwilloverheatthechimney
WARNING
Prefabricated Metal Chimney (Cont’d)
LINER CONNECTOR
FLUE GAS
DIRECTION
CRIMPED END
TOWARDS STOVE
Figure 16.1
NOTICE: In Canada when using a factory-built chim-ney it must be safety listed, Type UL103 HT (2100oF) [1149oC] CLASS “A” or conforming to CAN/ULC-S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.
*Youwillneed toaddadditionalclearances to thesedimensions foryourspecific installation.Alsoallowsufficientclearanceifyouare installinganoutsideairkit.
NOTE: Refer to chimney liner manufacturer for recom-mendations on supporting the liner. Installation into fireplaceswithoutapermitwillvoidthelisting.
H. Altering the Fireplace
G. Securing Chimney ComponentsAll joints should be secured with 3 sheet metal screws orrivetsperpipemanufacturersinstructions.Thesectionsmustbeattachedtotheinsertandtoeachotherwiththecrimped(male)endpointingtowardtheinsert.Figure 16.1.
WARNING! Risk of Fire!Followventingmanufacturer’sclearancesand instructionswheninstallingventingsystem.
March 17, 2014 7063-513 17
VOYAGEUR
J. Ovalizing Round Stainless Steel LinersOvalizing roundstainlesssteel liners toaccommodate thelinerpassingthroughthedamperregionofafireplaceisanallowableandacceptablepractice.Ensure that the ovalization is minimized to the extentrequiredtofitthroughthedamper.
Fire Risk.Do NOT pack insulation or other combustibles
between spacers.• ALWAYSmaintainspecifiedclearancesaround
venting and spacers.• Installspacersasspecified.Failure to keep insulation or other material away fromventpipemaycausefire.
WARNING
WARNING! Risk of Asphyxiation!• DONOTCONNECTTHISAPPLIANCETO
ACHIMNEYFLUESERVICINGANOTHERAPPLIANCEORTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
Thismayallowfluegasestoenterthehouse.
K. Chimney Height / Rise and RunTobesurethatyourQuadra-Fireinsertburnsproperly,thechimneydraft(staticpressure)shouldbeapproximately-0.10incheswater column (W.C.) duringa highburnand -0.04inchesW.C.duringalowburn,measured6inches(152mm)abovethetopoftheinsertafteronehourofoperationateachburnsetting.
NOTE:Theseareguidelinesonly,andmayvarysomewhatforindividualinstallations.
• This productwas designed for and tested on a 6 inch(152mm) chimney, 14 to 16 feet (4.27-4.87m) high, (in-cludesapplianceheight)measuredfromthebaseoftheappliance.
• Thefurtheryourstackheightordiametervariesfromthisconfiguration,thepossibilityofperformanceproblemsex-ists.
• Chimneyheightmayneedtobeincreasedby2 - 3% per each1000feet(304.8m)abovesealevel.
• Itisnotrecommendedtouseoffsetsorelbowsataltitudesabove4000feet(1219.2m)abovesealevelorwhenthereareotherfactorsthataffectfluedraft.
Fire Risk.This appliance relies upon natural draft to operate
properly.• Chimneyheightsexceeding25feet(7.62m)from
base of appliance may create an over-draft situation.
• Overdraftconditionmaycreateover-firing.Over-firingmayignitecreosoteand/ordamage
appliance and chimney
WARNING
I. Zero-Clearance FireplaceApermitmayberequiredfor installations,finalapproval iscontingentoftheauthorityhavinglocaljurisdiction.Consult insurance carrier, local building, fire officials or authoritieshavingjurisdictionaboutrestrictions,installationinspection,and permits.
Inspecttheexistingfireplaceandchimneyforanydamageorflawssuchasburnouts,metalorrefectorywarping.
Inspection to a minimum of NFPA 211 Level II is recom-mended. All repairs must be made prior to installing aninsert.Thefireplacemustbestructurallysoundandbeableto support the weight of the solid-fuel insert
Thefactory-builtchimneymustbelistedperUL127orULC610-M87 for all installations. Install thermal protection per thisappliancelistingrequirements.
A full height 6 inch diameter stainless steel full height listed chimney liner must be installed meeting type HT (2100°F)requirementsperUL1777(USA)orULCS635with “0” clearance to masonry (Canada). The full liner mustbeattachedtotheinsertfluecollarandtothetopof the existing chimney.
Thefluelinertopsupportattachmentmustnotreducetheairflowfortheexistingair-cooledchimneysystem.Re-installoriginal factory-built chimney caponly. (See Section F., PrefabricatedMetalChimney)
Toprevent roomair passage to thechimneycavityof thefireplace,sealeither thedamperareaaroundthechimneylinerortheinsertsurround.Circulatingairchamber(i.e.inasteelfireplacelinerormetalhearthcirculator)maynotbeblocked.Theairflowwithinandaroundthefireplaceshallnotbealtered,blockedbytheinstallationoftheinsert.(i.e.nolouversorcoolingairinletoroutletportsmaybeblockedbytheinsertortheinsertsurround.
See“H.AlteringtheFireplace”formodificationsallowedforfactory-builtfireplaces.
18 7063-513 March 17, 2014
VOYAGEUR
Figure18.1
Grille hinges downward
Remove Screws & Pull Access Assembly
away from InsertRemove Outside Cover
Plate A (Discard)
Figure18.2
Outside Air Cover Plate B (Discard)
Termination Cap
Flex Adapter
Items Needed for Installation (not supplied) • 4 inch flex aluminumpipe, or if using alternatematerial,
thenitshallbemadefromdurable,non-combustible,heatresistant material up to 350oF.Cutthepipetotherequiredlength for your installation.
•Phillipsheadscrewdriver •5/32AllenWrench •Siliconesealant
A. Outside Air Kit InstallationAsourceofair (oxygen) isnecessary inorder forcombustionto take place. Whatever combustion air is consumed by thefiremustbe replaced. Air is replacedviaair leakagearoundwindows and under doors. In homes that have tightly sealeddoors and windows, an outside air source is needed. An optional OutsideAirKitisavailable.
WARNING
Donotdrawoutsidecombustionairfrom:
• Wall,floororceilingcavity• Enclosedspacesuchasanatticorgarage• Closeproximitytoexhaustventsor
chimneysFumes or odor may result
Fire Risk.Asphyxiation Risk.
Asphyxiation Risk. Outsideairinletmustbelocatedtopreventblockagefrom:
• Leaves,snow,iceorotherdebrisBlockmaycausecombustionairstarvation
Smokespillagemaysetoffalarmsorirritatesensitiveindi-viduals.
WARNING
Asphyxiation Risk.LengthofoutsideairsupplyductshallNOTexceedthelengthoftheverticalheightoftheexhaustflue.• Firewillnotburnproperly• Smoke spillage occurs when door is opened due
toairstarvation.
WARNING
If Not Installing the Outside Air Kit1. Swinggrilledowntoexposethetwoscrews.Figure
18.12. Removethetwoscrewsandpulltheaccessassembly
away from the appliance.3. RemovetheoutsideaircoverplateAanddiscard.4. Re-installtheaccessassembly.
Option One - Outside Air Installation Instructions1. RemovetheoutsideaircoverplateBonoutercananddis-
card. Figure18.2.2. Install optional flex adapter to outer can with the same
screws. Do not use plastic wire ties that come with the kit astheywillmelt.NOTE:Youmayneedtoinstalltheflexpipe into thefireboxfirstdependingon installation.Attachflextoadapterwithatleast2screws.
3. Ensureexistingaccessholeinfireplaceissufficienttofeedthe4inchflex.
4. Afterslidingcanintofireplace,feedflexintocutopeningtoobtainoutsidecombustionair.
5. Leveloutercanandinstallappliance.Seepage 19.
Option Two - Installation Instructions
1. Removetheoutsideaircoverplateonoutercananddis-card and reuse the 4 screws
2. Ensureexistingaccessholeinfireplacewillnotbecoveredby theouter can.Existingoutsideair intakeholemaybeunderattherearorsideofoutercan.Outsideairmayalsoenterdownexistingchimneychaseinsomesituations.
3. Repeatsteps5through9abovewithoneexception.Afterinstallingtheapplianceintheoutercan,sealthefireplaceopeningandtrimpackagewithinsulationtopreventairleak-age into the room.
5 Appliance Set-Up
March 17, 2014 7063-513 19
VOYAGEUR
Flue Collar Stove Pipe/Liner
Gasket
Figure 19.1
B. Securing Stove Pipe/Liner to Flue Collar1.Thereare4pre-drilledholesinthefluecollar90degrees
apart.Attachthefluecollartothestovepipe/liner.IfthesealisquestionableusehightemperaturesealantsuchasstovemasticFigure 19.1.
2.Attachgaskettobottomsideoffluecollarwithathincoatof silicone.
D. Optional Elbow Flue Adapter InstallationOptionaluseofaSimpsonDuravent15°UniversalElbowPartNumber4615 maybepurchaseddirectlythroughyourlocalSimpsonDurventPipeDistributor or from your localQuadra-Firedealer,PartNumberDV-6DLR-E15ADSS.Figure 19.2 shows a vertical installation and also how tocreateanoptional30°elbowinstallation.
The 15° elbowmay be secured directly to the flue collar.Followthepipemanufacturer’sinstructionsforusingscrewsor rivets forattachment. Mostpipemanufacturer’s6 inch(152mm)diameterfluelinersmaybeattacheddirectlytothetopofthe15°elbow.
C. Leveling Legs1.Removethe2screwsalreadyinstalledoneachleg.2.Movelegstothedesiredheight.3. Re-install the screws to secure in place.
Remove 2 screws from both sides. Adjust the legs up or down to level appliance.
A
B30 degree
30o
A
BVertical
Figure 19.2
FlueAdapter
A BVertical 13-9/16in.(344mm) 20-15/16in.(532mm)
30 Degree 14-5/8in.(371mm) 20-11/16in.(525mm)
20 7063-513 March 17, 2014
VOYAGEUR
Corner Brackets
Figure 20.2
Figure 20.3
Strain Relief for Blower Cord and Cover Plug for hole in each side
Secure 2 Sides to Top
Mounting Tabs Slide into Slots on Firebox Face
Secure to Firebox Face
Heat Deflector
5/16 Nuts
Attachment Bar
5/16 Bolts
Figure 20.1
E. Securing Appliance to Stove Pipe/Liner1. Once you have the appliance in place and secured,
remove the tube channel assembly, baffle board andceramicblanket.
2.Reachupthroughtheflueopeningandgrabtheattach-mentbarandpulldowninsideflueopening. Figure 20.1.
2. Insertthe5/16boltsinsidethecastflueandthroughthechimneymountingbar.Securelytightenthenuts.Fas-tenersareprovided.
3. Re-install the tube channel assembly, baffle board,ceramicblanketandbaffleprotectionchannel.
F. Surround & Trim Kit Installation StandardSize:43in.Wx31in.H LargeSize:51in.Wx34in.H1. Lay surround face down on a protected surface to pre-
ventscratching.2. Using a 4 to 6 inches long Phillips head screw driver
attach thesidesurrounds to the topsurroundusing(2)#8sheetmetalscrewsoneachsideprovidedwiththekit. Figure 20.3.
3. Laythetrimfacedownandplacethecornerbracketsintoposition.
4. Using a standard flat screw driver tighten the cornerbrackets.Figure 20.2.
5. Slidetheassembledtrimsetoverthesurroundset.andthenovertheappliancematchingthemountingtabsonthe side pieces with the slots on the appliance. Figure 20.3.
6. Align the 2 screws in the top surround piece to the 2 alignment holes on the appliance top. Secure in place. Figure 20.3.
7. Usethestrainreliefinthesurroundsideforblowercordinstallationandusethecoverplugtoinsertintotheholewheretheblowercordisnotinstalled.
March 17, 2014 7063-513 21
VOYAGEUR
StandardSize:42-1/2in.Wx30in.HLargeSize:48in.Wx34in.H
Included in Surround Kit:(2)sidepieces,leftandright;(1)ltoppiece;(1)fastenerpackage.
Included in Cast Trim Kit: (2)casttrimlegs,leftandright;(1)casttrimheader;(2)casttrimfooters,leftandright;(1)fastenerpackage.
Tools Needed: Powered 4 to 6 inches long Phillips head screwdriver;pliers
1. Removecontents fromboxbeingcarefulnot toscratchordamage the cast trim pieces.
2. Laysurroundfacedownonaprotectedsurfacetopreventscratching.
3. Usinga4to6incheslongPhillipsheadscrewdriverattachthesidesurroundstothetopsurroundusing(2)#8sheetmetalscrewsoneachsideprovidedwiththekit.
4. Placethepeelandstickroundfeltvibrationinsulationpadson the front side in each corner of the top metal piece and onthebacksideineachcornerofthetopcastpiece.Figure 21.1.
5. Place the corresponding cast trim pieces (2 cast trim sides and1casttrimheader)underneaththepanelset,alsofacedown.Aligntheholesinthemetalpieceswiththe5bossesonthetopcastpieceand2bossesoneachsidepiece.
6. Securethemagnettothebracketandattachthemagnetandbrackettoeachmetalsidepieceatthebottom.Themagnet
G. Standard Surround & Cast Trim Kit
(4) Felt Vibration Insulation Pads
Secure Surrounds to Cast Trim Kit
Attach Magnet before installing Cast Footers
Magnet Installed
Cast Footers, Left & Right
Figure 21.1
Back of Side Piece
Magnet Attached - Faces Front
Clearance Notch
is facing the front. Figure 21.2.7. Place the cast footers under the metal sides aligning the top
andbottomholesinthecastfootersandmetalsides.
8. The9mountingclipsareshipped inone longstrip. Handbreakapartorusepliers.
9. Each clip has a clearance notch to allow room for the cast on the insert. Place the clip so the notch is facing the outer edges of the surrounds. Figure 21.3.
10.Itisbesttoinstallallofthe1/4-20screwsonlyhalfwayatfirsttoallowforadjustments.Afteradjustment,tightenthe2screwsineachcastfooterfirstandthenworkyourwayaroundto the rest.
11.Slidesurroundandtrimoverthetopoftheinsertintoplacematchingthemountingtabsonthemetalsideswiththeslotson the insert. Figure 21.4.
12. Align the 2 screws in the top metal surround piece to the 2 alignment holes on the appliance top. Secure in place. Figure 21.4.
Figure 21.2
Figure 21.3
Match Mounting Tabs to Slots on the appliance
Figure 21.4
22 7063-513 March 17, 2014
VOYAGEUR
Size:40in.Wx30in.HIncluded in Surround Kit:(2)sidepieces,leftandright;(1)ltoppiece;(1)fastenerpackage.
Tools Needed: Powered 4 to 6 inches long Phillips head screwdriver;pliers
1. Removecontents fromboxbeingcarefulnot toscratchordamage the cast trim pieces.
2. Lay surround pieces face down on a protected surface to preventscratching.
3. Alignthebossesonthetoppiecetotheholesonthesidepieces. Secure the 3 pieces together.
4. Attachthemountingbracketstothesidepiecesincludedwiththe kit. Figure 22.1.
5. In order to get a tight seal for the surround, you must reposition asideshield.Therearetwoholesontheshieldanditwillcomefromthefactorysecured in thefirst (left)hole. Removetheshieldandre-installusingthesecond(right)hole.Figure 22.2.
5. Position the trim on the appliance matching up the mounting bracketswiththeslotsontheappliance.
6. Attach the surround to the appliance 2 screws. DO NOT OVERTIGHTEN SCREWS - MAY DAMAGE PORCELAIN FINISH.
H. All Cast Surround Kit
4 Mounting Brackets
Mounting Brackets
Attach to Appliance with Screws
Remove and Reposition Side Shield using Second HoleDo not overtighten - may
damage porcelain finish
Figure 22.1
Figure 22.2
I. Blower Cord Installation on Left Side Theblowercordisshippedtobeinstalledontherightsideof the appliance. You may relocate the cord so it is on the left side. Overview: You are removing the power cord from theblower controls, re-routing the cord to the left side andre-installingthepowercordtotheblowercontrols.Refertotheexplodeddrawingonpage 23.
1. Swingthegrilledowntoexposethe2bolts,oneateachend. Remove theboltsandpullbloweraccessassemblyawayfromapplianceandstoreaway from your work area.
2. Removethe2screwsintheholddownbracketinfrontoftheblowerassembly.Youdonotneedtoremovetheblowerfromtheholddownbracket.
3. Disconnect the2blowerwires thatareattachedtothewireharnessandpulltheblowerassemblyaway from the appliance.
Figure 22.3
Figure 22.4
March 17, 2014 7063-513 23
VOYAGEUR
Figure 23.1
Blower Access Assembly
Grille hinges downward
Remove Screws & Pull Access Assembly
away from Insert
Hold Down Bracket
Remove Screws from Hold Down Bracket and Pull Blower Assembly
Forward. Do not Remove Blower from the Hold Down Bracket
Placement Slot
Blower Control Plate
Snap Disc Bracket
4. Remove the 2 screws at the top of the controlplate.Pushthebottomofthecontrolplatetotheinsideof theapplianceandpartially remove thecontrolplateassembly.
White Wire
Black Wire
Figure 23.2
5. Locatetheblackandwhitewiresthatarepartofthe power cord and disconnect those wires from the wire harness.
Green Grounding Wire
Remove Screw
6. Removethescrewthatisholdingthegroundlugto the control plate.
Figure 23.4
Figure 23.57. Use needle nose pliers to remove the strain relief
that protects the power cord from the control plate.
Figure 23.3
24 7063-513 March 17, 2014
VOYAGEUR
8. Thepowercordisnowdisconnectedfromtheblowercontrol plate. Pull the cord out through the right side of the appliance.
Route Cord Through Retainer Clip
Grommet
9. Insert the power cord through the left side of the appliance in the hole contains the grommet. Pull the connection ends to the right side. Route the power cord through the retainer clip.
Strain Relief
10. Replace the strain relief on the power cord in the samepositionasbefore.Locatetheindentationonthecordmadeby thestrain relief. Oncereplaced,pushthestrainreliefbackintothecontrolplate.
White Wire
Black Wire
Fiber Wrapped
Wire
Green Grounding
Wire
11. Connect the white wire on the power cord into the fiberwrappedwireonthewireharness.Connecttheblackwireonthepowercordtothewhitewireontherheostat. Re-attach the green ground terminal to the control plate.
12.Insert the control plate assembly back into theapplianceasshown.Tilttheassemblyforwardandthenliftupandrotatethebottomtowardsthefrontof the appliance at the same time ensure that the snap disc holder is properly seated. Secure plate to the appliance.
Figure 24.1
Figure 24.2
Figure 24.3
Figure 24.4
Figure 24.5
Route Wires through Retainer Clip
Replace Screws in Hold Down Bracket
13.Push in the blower and hold down bracket intoappliancematchingupthetabonthebracketandplacement slot on the appliance. Secure bracketand reconnect blowerwires (no polarity toworryabout)routingwiresthroughtheretainerclip.
Figure 24.6
March 17, 2014 7063-513 25
VOYAGEUR
Figure 25.1
Spark Arestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop Double Wall Connector Pipe
8. Burnwoodonly. Other types of fuelsmaygeneratepoisonousgases(e.g.,carbonmonoxide).
9. Ifunitburnspoorlywhileanexhaustblowerisoninhome,(i.e.,rangehood),increasecombustionair.
10. InstallationshallbeinaccordancewiththeManufacturersHome&SafetyStandard(HUD)CFR3280,Part24.
NOTICE: • Offsetsfromthevertical,notexceeding45°,areallowedperSection905(a)oftheUniformMechanicalCode(UMC).
• Offsetsgreaterthan45°areconsideredhorizontalandarealsoallowed,providingthehorizontalrundoesnotexceed75%oftheverticalheightofthevent.
• Construction,clearanceandterminationmustbeincom-pliancewiththeUMCTable9C.Thisinstallationmustalsocomply with NFPA 211.
NOTICE:Topsectionsofchimneymustberemovabletoallowmaximumclearanceof13.5feet(411cm)fromgroundlevelfor transportation purposes.
1. Anoutsideairinletmustbeprovidedforcombustionandmustremainclearofleaves,debris,iceand/orsnow.Itmustbeunrestrictedwhileunitisinusetopreventroomairstarvationwhichcancausesmokespillageandaninabilitytomaintainafire.Smokespillagecanalsosetoff smoke alarms.
2. Unitmustbesecuredtothemobilehomestructureattwoattachmentpoints.Removeboltsfromeachsideofinsertanduseplumberstapetosecuretostructure(awashermayberequired).Re-installbolts.
3. Unitmustbegroundedwith#8solidcoppergroundingwireorequivalentandterminatedateachendwithN.E.C.approvedgroundingdevice.
4. The factory-built fireplacemustmeet (UM)84-HUDrequirements for outside combustion air supply tothe fireplace fire chamber and the chimneymust belisted toUL103HTora listedUL-1777 full lengthsixinch(152mm)diameterlinermustbeused.Itmustbeequippedwithasparkarrestorcapandtheoutsideairmustbeinstalledontheinsert.
5. Refer to pages 7-8 of this manual for clearance to combustibles and floor protections requirements. All clearancesmustbefollowedprecisely.
6. Use silicone to create an effective vapor barrier atthe location were the chimney or other component penetratestotheexteriorofthestructure.
7. Followthechimneyandchimneyconnectormanufacturer’sinstructionswheninstallingthefluesystemforuseinamobilehome.
CAUTIONTHESTRUCTURALINTEGRITYOFTHEMOBILEHOMEFLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINEDDoNOTcutthrough:• Floorjoist,wall,studsorceilingtrusses.• Any supporting material that would affect the structural integrity.
• NEVERINSTALLINASLEEPINGROOM.Consumesoxygenintheroom.
WARNINGAsphyxiation Risk.
WARNING
Donotdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsorchimneys.
Fumes or odor may result
Fire Risk.Asphyxiation Risk.
6 Mobile Home Installation
26 7063-513 March 17, 2014
VOYAGEURService Parts VOYAGEUR
Beginning Manufacturing Date: Sept 2010 Ending Manufacturing Date: Active
R
IMPORTANT:THISISDATEDINFORMATION.Whenrequestingserviceorreplacementpartsforyourappliancepleaseprovidemodelnumberandserialnumber.Allpartslistedinthismanualmaybeorderedfromanauthorizeddealer.
Stockedat Depot
ITEM DESCRIPTION COMMENTS PART NUMBERSurrounds see diagrams on following page.
27
Surround, All Metal Standard SP-VOYA-STD
Surround, All Metal, Large SP-VOYA-LRG
TrimKitBlack TRIMKIT-4331-BK
Gold TRIMKIT-4331-GD
Nickel TRIMKIT-4331-NL
TrimKitBlack TRIMKIT-5134-BK
Gold TRIMKIT-5134-GD
Nickel TRIMKIT-5134-NL
Surround,Cast-Metal Standard SP-VOYA-CM-STD
Surround, Cast-Metal, Large SP-VOYA-CM-LRG
CastTrimBlack 811-0930
Porcelain Mahogany 811-0960
Surround Complete Cast Matte Black SP-VOYA-CC-MBK
Surround Complete Cast Porcelain Mahogany SP-VOYA-CC-PMH
FASTENERSBolt(1/4-20x3/4) Pkgof4 812-2350 YBolt(5/16x18x1) Pkgof12 27887/12 YBolt,Shoulder,(5/16X1/4-20) Pkgof20 223-0170/20 YNut(5/16-18) Pkgof10 A-3483-1/10 YNut2-wySide-LockJam3 Pkgof24 226-0100/24 YNut flange(1/4-20) Pkgof24 226-0130/24 YNutLock(1/4-20) Pkgof25 226-0090/25 YScrew(10-32x.75)HWHSF Pkgof4 7000-618/4 YScrew,5/16x5/8ShoulderHH Pkgof4 7000-331/4 YScrew,FHHX(1/4-20x1) Pkgof6 7000-622/6 YScrew,FlatHeadPhilips8-32X1/2 Pkgof10 832-0860 YScrew,HWHMS(1/4x3/4NS) Pkgof25 220-0080/25 YScrew,PanHeadPhilips(8-32X3/8) Pkgof40 225-0500/40 YScrew,PH,PHLTC(8-32x1-2) Pkgof25 220-0030/25 YScrew,SheetMetal#8X1/2S-Grip Pkgof40 12460/40 YWasher5/16 Pkgof10 7000-579/10 YWasherSAE#10 Pkgof25 227-0080/25 YWasherSpring5/16 Pkgof4 7000-572/4 YWasher,(5/8x.406) Pkgof10 7000-116/10 YWasher,1/4Sae Pkgof24 28758/24 Y
Additionalservicepartnumbersappearonfollowingpage.
DESCRIPTION COMMENTS PART NUMBER STOCKED at DEPOT
A. Accessory List
7 Accessory List
March 17, 2014 7063-513 27
VOYAGEUR
B. Service and Maintenance Log
Date of Service Performed By Description of Service
28 7063-513 March 17, 2014
Hearth & Home Technologies1445 North HighwayColville, WA 99114
Division of HNI INDUSTRIES
We recommend that you record the following pertinent information for your heating appliance.
Date purchased/installed:
Serial Number: Location on appliance:
Dealership purchased from: Dealer phone:
Notes:
DO NOT DISCARD THIS MANUALCAUTION
• Importantoperatingandmaintenance instruc-tionsincluded.
• Leave thismanualwithpartyresponsibleforuseandoperation.
• Read,understandandfollow these instruc-tionsforsafeinstalla-tionandoperation.
DO NOTDISCARD
Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer
log onto www.quadrafire.com
CONTACT INFORMATION
Thisproductmaybecoveredbyoneormoreofthefollowingpatents:(UnitedStates)5341794,5263471,6688302,7216645,7047962orotherU.S.andforeignpatentspending.