About this document
This document provides a comprehensive overview of all necessary installation tasks for the HYBRIFLEX™ Solution. It includes a step-by-step-guide that explains how to handle and assemble all necessary HYBRIFLEX solution piece parts.
A typical HYBRIFLEX solution per site (max. configuration) contains:
3 HYBRIFLEX riser cable
12 HYBRIFLEX jumper cables
3 distribution boxes
1 patch panel
24 patch cords
2 loop back connectors
Note:
These instructions are written for
qualified and experienced
installation personnel.
Please read this document
carefully before starting any work.
Any liability or responsibility for
the results of improper or unsafe
installation is disclaimed.
Please respect valid
environmental regulations for
assembly and waste disposal.
Always use appropriate personal
protection and observe all work
safety and security precautions in
accordance with local regulations
during installation.
Contents 1. Mounting the HYBRIFLEX
jumper in the box 3
1.
2. Mounting the box to
the pole 5
3. Mounting a HYBRIFLEX riser
cable in the box 7
4. Hoisting and mounting the
riser cable 9
5. Grounding of riser cable 10
6. Over length management 11
6. Mounting the patch panel in
a 19 inch rack 12 12
7. Changing jumper cables in
the field 13
Tools Required Philips (cross) screwdriver
Flat head screwdriver
13 mm open-ended spanner
19 mm open-ended spanner
5 mm Allen key
Standard pipe cutter
Rip Tool HTRT-1-000
JSTRIP-78-2
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 3 of 13
1. Mounting the HYBRIFLEX jumper in
the box
Loosen the compression nuts of the cable glands to allow the jumper to be fed through the gland.
Caution:
Do not lose the
compression nuts!
Open the jumper grounding bars by loosening the corresponding screws.
Tools required: Phillips (cross) screwdriver
Starting with the bottom left gland (grounding bar marked in green) feed the fiber optic cable from the jumper through the cable gland and the grounding bar.
Caution: To minimize the risk of
increased fiber attenuation,
do not kink or bend the
cable too sharply.
Temporarily affix the fiber optic cable to the over length holder.
Feed DC cable and armor of the jumper through the cable gland and the grounding bar.
Fix grounding bar to the armor and tighten until the screw reaches its mechanical stop.
Connect the DC cables to the screw terminal. Match each cable to its corresponding color-coded terminal.
Tools required: Flat head screwdriver
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 4 of 13
Repeat this process with the
Bottom right gland (grounding bar marked magenta)
Top left gland (grounding bar marked yellow)
Top right gland (grounding bar marked white)
Lay the fiber optic cables clockwise into the over length holders and terminate each cable at the fiber optic adapters.
Make sure that the fiber optic connectors with a red boot are connected to the bottom adapter (marked red), and that the connectors with a blue boot are connected to the top adapters (marked blue).
Caution: Clean the fiber optic
connectors before
connecting them.
Use only approved fiber optic
connector cleaning kits.
Tighten the glands to seal the cables – hand tight only.
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 5 of 13
I-N
G-H B
C-F A
2. Mounting the box to the pole
Check the mounting hardware to make sure all parts are included. A complete kit includes:
2 pole mounting devices 2 fixing brackets 4 M6x20 hexagon socket screws including nuts and washers 4 fiberglass reinforced plastic latches with securing screws (in a plastic bag) 4 M8x150 machine screws including nuts and washers
Click the plastic latches into the back of the box.
Fix the latches with securing screws.
Tools required: Phillips (cross) screwdriver
When installed, the latches should point to the top and to the bottom (not to the left or to the right).
Attach the pole mounting devices to the latches using the four M6 x 20 hexagon socket screws.
Tools required: Allen key and 13 mm open-ended spanner
C-F
B
G-H
I-N
A
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 6 of 13
Mounting to the pole is achieved with the two fixing brackets. One is mounted at the top and the other at the bottom of the box.
Secure each bracket to the pole with two M8 x 150 machine screws and their corresponding nuts and washers per bracket.
Tools required: 19 mm open-ended spanner
The Box´s outer grounding terminal
can be terminated by means of
A: using a cable lug installed directly
on the grounding stud
1. Remove nut from grounding stud 2. Feed cable lug over stud 3. Replace and tighten nut
B: Using a bare wire and the transverse
hole of the grounding terminal
1. Loose nut on grounding stud 2. Feed cable through transverse hole
of stud 3. Tighten nut
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 7 of 13
3. Mounting a HYBRIFLEX riser cable
in the box
Use a standard cable clamp to temporarily attach the riser to the infrastructure. This will simplify the assembly process.
Open the riser grounding bar by loosening the corresponding screws.
Tools required: Phillips (cross) screwdriver
Feed fiber optic cable from the riser cable through the cable gland and the grounding bar. Start with the bottom left gland (grounding bar marked in green).
Caution: Do not remove the
protective bubble wrap foil
because it will make the
insertion process easier.
To minimize the risk of
increased fiber attenuation,
do not kink or bend the
cable too sharply.
Temporarily attach the fiber optic cable to the over length holder.
Feed the DC cable and armor of the jumper through the cable gland and the grounding bar.
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 8 of 13
Attach the grounding bar to the armor and tighten to mechanical stop.
Tools required: Phillips (cross) screwdriver
Connect the DC cables to the screw terminal. Match each cable to its corresponding color-coded terminal.
Tools required: Flat head screwdriver
Lay the fiber optic cables counter-clockwise into the over length holders and terminate each cable at the fiber optic adapters.
Make sure that the fiber optic connectors with a red boot are connected to the bottom adapter (marked red), and that the connectors with a blue boot are connected to the top adapters (marked blue).
Caution: Clean the fiber optic
connectors before
connecting them.
Use only approved
fiber optic connector
cleaning kits.
Tighten the glands to seal the cables – hand tight only (Gland P 3,5 – 5Nm / Gland Q 9 -11 Nm).
Close the box door and tighten the locking screws hand tight to achieve proper sealing.
Tools required: Phillips (cross) screwdriver
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 9 of 13
4. Hoisting & Mounting the riser cable
Check materials to make sure all parts
are available. The following are required
to mount and adjust the riser cable:
Pre-connectorized HYBRIFLEX Riser Cable assembly
GKSPEED Earthing Kits (if applicable)
Clamps (if applicable)
Rip tool (HTRT-1-000), electrical screwdriver, pipe cutter
Unpack the HYBRIFLEX cable and
prepare it for hoisting:
Attach the hoisting grip to the armored part of the cable.
Attach individual DC and fiber optic cables to the hoisting rope (this can be done with insulation tape).
Ensure that the fiber optic connectors distribution parts of the riser cable should not be unpacked before connecting it to the Distribution Box (DB) or Baseband Unit (BBU).
Hoist the HYBRIFLEX cable:
Based on cable length and site conditions, this can be accomplished manually or by means of a winch. The maximum pulling length per hoisting grip should not exceed 50m. If a second hoisting grip is needed, make sure the cable between the hoisting grips hangs with a bit of slack.
Extend the required cable length up to the entrance of the distribution box. Then attach the main part of the cable temporarily as near as possible to the box.
Before removing the hoisting grip, install a minimum of three cable clamps to the top of the horizontal run to prevent the cable from slipping. Use MBHS78-1-F (single layer) or MBHS78-3-F (triple layer) cable clamps.
Complete all the connection work described in Section 3.
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 10 of 13
Clamping
Install the remaining clamps, starting at the top and moving down along the structure.
Pre-install the clamps to the structure.
Clamp the cable into the clamps.
Remove the hoisting grip when the clamping process is completed.
Tools required: 13 mm open-ended spanner
5. Grounding of riser cable
For this project three grounding points are foreseen:
On the top near to the distribution box
Before transition from vertical to horizontal cable run
Before entering the building / outdoor cabinet for BBU
Clean the jacket at the desired grounding point and cut out a strip of 20mm (0.8 in) with the stripping tool JSTRIP-78-2 (do not damage the outer conductor!)
Remove covering paper from Butyl carefully in direction of the arrow and pre-bend the grounding body. Align the grounding kit body to the slot (grounding wire on the bottom side) and wrap it around the cable. Make sure wire mesh keeps in place in the body and is placed in the dismantled area. Do not turn or move the body after wrapping around the cable, otherwise butyl sealing could be damaged.
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 11 of 13
Tighten the two screws alternating (6-10 Nm)
Straighten the grounding wire in the direction to the grounding point (shortest way possible). The fixation of the wire is recommended. Note the standard & local rules.
Tools required: JSTRIP-78-2, Flat head screw driver, 5mm Allen key
6. Over length management
Typically, an excess length of the main cable is not stored. If installation results in an over length of HYBRIFLEX cable, the excess cable can be cut easily by removing the armor and the jacket from the excess length.
Start by determining the new break point and cut the armor and jacket using a standard pipe cutter.
The HYBRIFLEX cable is constructed with a built-in Kevlar rip cord, which allows cutting longitudinally through the armor and jacket. To simplify the cutting process, use the RFS rip tool (HTRT-1-000) with an electric screwdriver.
Remove the armor and jacket.
Tools required: Standard pipe cutter Rip Tool HTRT-1-000
Caution: Wear protective gloves
during this process!
Remove the protective foil from the inner core.
Note that DC cables can be cut to the desired length, while pre-connectorized fiber optic cables can be coiled to a handy ring that can be stored in the 19” patch panel.
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 12 of 13
7. Mounting the patch panel in a 19
inch rack
Typically, the fiber optic distribution and patch panel is mounted using a cage nut.
Hold the patch panel in position…
… and mount it using rack-screws with plastic washers. Note that these screws are not part of the patch panel package. They should be part of the 19” rack.
Tools required: Phillips (cross) screwdriver
The drawer can be opened by raising the front panel.
HYBRIFLEX™ Solution For Qtel Group
© RADIO FREQUENCY SYSTEMS 2012. ALL RIGHTS RESERVED
5100005-D
Page 13 of 13
Feed the fiber optic cables through one of the four cable entries in the back of the drawer. The single excess cables can be secured in multiple positions using cable ties.
Caution: To minimize the risk of
increased fiber attenuation,
do not kink or bend the
cable too sharply.
Connect the fiber optic connectors to the adapters.
The dust caps on the connectors and adapters can be stored in the drawer for later use. But dust caps should be stored in dust protective packaging before storage.
Caution: Clean the fiber optic
connectors before
connecting them.
Use only approved
fiber optic connector
cleaning kits.
8. Changing jumper cables in the field
Remove the old jumper:
Disconnect the fiber optic connectors from the adapters and unwind the fiber optic cable from the over length holder.
Disconnect the DC cables from the screw terminal.
Open the jumper grounding bar and loosen the compression nut on the cable gland.
Carefully pull out the jumper.
Re-attach the new jumper:
Follow the detailed instructions in Section 1.